Meszaros-Beller L, Antico M, Fontanarosa D, Pivonka P. Assessment of thoracic spinal curvatures in static postures using spatially tracked 3D ultrasound volumes: a proof-of-concept study. Phys Eng Sci Med 2023; 46:197-208. [PMID: 36625994 PMCID: PMC10030537 DOI: 10.1007/s13246-022-01210-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Accepted: 12/12/2022] [Indexed: 01/11/2023]
Abstract
The assessment of spinal posture is a difficult endeavour given the lack of identifiable bony landmarks for placement of skin markers. Moreover, potentially significant soft tissue artefacts along the spine further affect the accuracy of marker-based approaches. The objective of this proof-of-concept study was to develop an experimental framework to assess spinal postures by using three-dimensional (3D) ultrasound (US) imaging. A phantom spine model immersed in water was scanned using 3D US in a neutral and two curved postures mimicking a forward flexion in the sagittal plane while the US probe was localised by three electromagnetic tracking sensors attached to the probe head. The obtained anatomical 'coarse' registrations were further refined using an automatic registration algorithm and validated by an experienced sonographer. Spinal landmarks were selected in the US images and validated against magnetic resonance imaging data of the same phantom through image registration. Their position was then related to the location of the tracking sensors identified in the acquired US volumes, enabling the localisation of landmarks in the global coordinate system of the tracking device. Results of this study show that localised 3D US enables US-based anatomical reconstructions comparable to clinical standards and the identification of spinal landmarks in different postures of the spine. The accuracy in sensor identification was 0.49 mm on average while the intra- and inter-observer reliability in sensor identification was strongly correlated with a maximum deviation of 0.8 mm. Mapping of landmarks had a small relative distance error of 0.21 mm (SD = ± 0.16) on average. This study implies that localised 3D US holds the potential for the assessment of full spinal posture by accurately and non-invasively localising vertebrae in space.
Collapse
Affiliation(s)
- Laura Meszaros-Beller
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia.
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, Australia.
| | - Maria Antico
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, Australia
- Australian e-Health Research Centre, Commonwealth Scientific and Industrial Research Organisation (CSIRO), Queensland, Australia
- School of Clinical Sciences, Queensland University of Technology, Brisbane, Australia
| | - Davide Fontanarosa
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, Australia
- School of Clinical Sciences, Queensland University of Technology, Brisbane, Australia
| | - Peter Pivonka
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, Australia
| |
Collapse
|
2
|
Gueziri HE, Georgiopoulos M, Santaguida C, Collins DL. Ultrasound-based navigated pedicle screw insertion without intraoperative radiation: feasibility study on porcine cadavers. Spine J 2022; 22:1408-1417. [PMID: 35523390 DOI: 10.1016/j.spinee.2022.04.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 04/15/2022] [Accepted: 04/26/2022] [Indexed: 02/03/2023]
Abstract
BACKGROUND Navigation systems for spinal fusion surgery rely on intraoperative computed tomography (CT) or fluoroscopy imaging. Both expose patient, surgeons and operating room staff to significant amounts of radiation. Alternative methods involving intraoperative ultrasound (iUS) imaging have recently shown promise for image-to-patient registration. Yet, the feasibility and safety of iUS navigation in spinal fusion have not been demonstrated. PURPOSE To evaluate the accuracy of pedicle screw insertion in lumbar and thoracolumbar spinal fusion using a fully automated iUS navigation system. STUDY DESIGN Prospective porcine cadaver study. METHODS Five porcine cadavers were used to instrument the lumbar and thoracolumbar spine using posterior open surgery. During the procedure, iUS images were acquired and used to establish automatic registration between the anatomy and preoperative CT images. Navigation was performed with the preoperative CT using tracked instruments. The accuracy of the system was measured as the distance of manually collected points to the preoperative CT vertebral surface and compared against fiducial-based registration. A postoperative CT was acquired, and screw placements were manually verified. We report breach rates, as well as axial and sagittal screw deviations. RESULTS A total of 56 screws were inserted (5.50 mm diameter n=50, and 6.50 mm diameter n=6). Fifty-two screws were inserted safely without breach. Four screws (7.14%) presented a medial breach with an average deviation of 1.35±0.37 mm (all <2 mm). Two breaches were caused by 6.50 mm diameter screws, and two by 5.50 mm screws. For vertebrae instrumented with 5.50 mm screws, the average axial diameter of the pedicle was 9.29 mm leaving a 1.89 mm margin in the left and right pedicle. For vertebrae instrumented with 6.50 mm screws, the average axial diameter of the pedicle was 8.99 mm leaving a 1.24 mm error margin in the left and right pedicle. The average distance to the vertebral surface was 0.96 mm using iUS registration and 0.97 mm using fiducial-based registration. CONCLUSIONS We successfully implanted all pedicle screws in the thoracolumbar spine using the ultrasound-based navigation system. All breaches recorded were minor (<2 mm) and the breach rate (7.14%) was comparable to existing literature. More investigation is needed to evaluate consistency, reproducibility, and performance in surgical context. CLINICAL SIGNIFICANCE Intraoperative US-based navigation is feasible and practical for pedicle screw insertion in a porcine model. It might be used as a low-cost and radiation-free alternative to intraoperative CT and fluoroscopy in the future.
Collapse
Affiliation(s)
- Houssem-Eddine Gueziri
- McConnell Brain Imaging Center, Montreal Neurological Institute and Hospital, McGill University, 3801 University St, Montreal, Quebec, Canada.
| | - Miltiadis Georgiopoulos
- Department of Neurology and Neurosurgery, Montreal Neurological Institute and Hospital, McGill University, 3801 University St, Montreal, Quebec, Canada
| | - Carlo Santaguida
- Department of Neurology and Neurosurgery, Montreal Neurological Institute and Hospital, McGill University, 3801 University St, Montreal, Quebec, Canada
| | - D Louis Collins
- McConnell Brain Imaging Center, Montreal Neurological Institute and Hospital, McGill University, 3801 University St, Montreal, Quebec, Canada; Department of Neurology and Neurosurgery, Montreal Neurological Institute and Hospital, McGill University, 3801 University St, Montreal, Quebec, Canada
| |
Collapse
|
3
|
Patel MR, Jacob KC, Parsons AW, Chavez FA, Ribot MA, Munim MA, Vanjani NN, Pawlowski H, Prabhu MC, Singh K. Systematic Review: Applications of Intraoperative Ultrasound in Spinal Surgery. World Neurosurg 2022; 164:e45-e58. [PMID: 35259500 DOI: 10.1016/j.wneu.2022.02.130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 02/28/2022] [Indexed: 10/18/2022]
Abstract
BACKGROUND Due to increased practicality and decreased costs and radiation, interest has risen for intraoperative ultrasound (iUS) in spinal surgery applications; however, few studies have provided a robust overview of its use in spinal surgery. We synthesize findings of existing literature on usage of iUS in navigation, pedicle screw placement, and identification of anatomy during spinal interventions. METHODS Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were utilized in this systematic review. Studies were identified through PubMed, Scopus, and Google Scholar databases using the search string. Abstracts mentioning iUS in spine applications were included. Upon full-text review, exclusion criteria were implemented, including outdated studies or those with weak topic relevance or statistical power. Upon elimination of duplicates, multi-reviewer screening for eligibility, and citation search, 44 manuscripts were analyzed. RESULTS Navigation using iUS is safe, effective, and economical. iUS registration accuracy and success is within clinically acceptable limits for image-guided navigation (Table 2). Pedicle screw instrumentation with iUS is precise with a favorable safety profile (Table 2). Anatomical landmarks are reliably identified with iUS, and surgeons are overwhelmingly successful in neural or vascular tissue identification with iUS modalities including standard B mode, doppler, and contrast-enhanced ultrasound (CE-US) (Table 3). iUS use in traumatic reduction of fractures properly identifies anatomical structures, intervertebral disc space, and vasculature (Table 3). CONCLUSION iUS eliminates radiation, decreases costs, and provides sufficient accuracy and reliability in identification of anatomical and neurovascular structures in various spinal surgery settings.
Collapse
Affiliation(s)
- Madhav R Patel
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Kevin C Jacob
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Alexander W Parsons
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Frank A Chavez
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Max A Ribot
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Mohammed A Munim
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Nisheka N Vanjani
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Hanna Pawlowski
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Michael C Prabhu
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612
| | - Kern Singh
- Department of Orthopaedic Surgery, Rush University Medical Center, 1611 W. Harrison St. Suite #300, Chicago, IL, 60612.
| |
Collapse
|
4
|
Multimodal 3D ultrasound and CT in image-guided spinal surgery: public database and new registration algorithms. Int J Comput Assist Radiol Surg 2021; 16:555-565. [PMID: 33683544 DOI: 10.1007/s11548-021-02323-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 02/08/2021] [Indexed: 10/22/2022]
Abstract
PURPOSE Accurate multimodal registration of intraoperative ultrasound (US) and preoperative computed tomography (CT) is a challenging problem. Construction of public datasets of US and CT images can accelerate the development of such image registration techniques. This can help ensure the accuracy and safety of spinal surgeries using image-guided surgery systems where an image registration is employed. In addition, we present two algorithms to register US and CT images. METHODS We present three different datasets of vertebrae with corresponding CT, US, and simulated US images. For each of the two latter datasets, we also provide 16 landmark pairs of matching structures between the CT and US images and performed fiducial registration to acquire a silver standard for assessing image registration. Besides, we proposed two patch-based rigid image registration algorithms, one based on normalized cross-correlation (NCC) and the other based on correlation ratio (CR) to register misaligned CT and US images. RESULTS The CT and corresponding US images of the proposed database were pre-processed and misaligned with different error intervals, resulting in 6000 registration problems solved using both NCC and CR methods. Our results show that the methods were successful in aligning the pre-processed CT and US images by decreasing the warping index. CONCLUSIONS The database provides a resource for evaluating image registration techniques. The simulated data have two applications. First, they provide the gold standard ground-truth which is difficult to obtain with ex vivo and in vivo data for validating US-CT registration methods. Second, the simulated US images can be used to validate real-time US simulation methods. Besides, the proposed image registration techniques can be useful for developing methods in clinical application.
Collapse
|
5
|
Gueziri HE, Yan CXB, Collins DL. Open-source software for ultrasound-based guidance in spinal fusion surgery. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3353-3368. [PMID: 32907772 DOI: 10.1016/j.ultrasmedbio.2020.08.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 07/10/2020] [Accepted: 08/05/2020] [Indexed: 06/11/2023]
Abstract
Spinal instrumentation and surgical manipulations may cause loss of navigation accuracy requiring an efficient re-alignment of the patient anatomy with pre-operative images during surgery. While intra-operative ultrasound (iUS) guidance has shown clear potential to reduce surgery time, compared with clinical computed tomography (CT) guidance, rapid registration aiming to correct for patient misalignment has not been addressed. In this article, we present an open-source platform for pedicle screw navigation using iUS imaging. The alignment method is based on rigid registration of CT to iUS vertebral images and has been designed for fast and fully automatic patient re-alignment in the operating room. Two steps are involved: first, we use the iUS probe's trajectory to achieve an initial coarse registration; then, the registration transform is refined by simultaneously optimizing gradient orientation alignment and mean of iUS intensities passing through the CT-defined posterior surface of the vertebra. We evaluated our approach on a lumbosacral section of a porcine cadaver with seven vertebral levels. We achieved a median target registration error of 1.47 mm (100% success rate, defined by a target registration error <2 mm) when applying the probe's trajectory initial alignment. The approach exhibited high robustness to partial visibility of the vertebra with success rates of 89.86% and 88.57% when missing either the left or right part of the vertebra and robustness to initial misalignments with a success rate of 83.14% for random starts within ±20° rotation and ±20 mm translation. Our graphics processing unit implementation achieves an efficient registration time under 8 s, which makes the approach suitable for clinical application.
Collapse
Affiliation(s)
- Houssem-Eddine Gueziri
- McConnell Brain Imaging Center, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.
| | - Charles X B Yan
- Joint Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada
| | - D Louis Collins
- McConnell Brain Imaging Center, Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada
| |
Collapse
|
6
|
Lavenir L, Zemiti N, Akkari M, Subsol G, Venail F, Poignet P. HFUS Imaging of the Cochlea: A Feasibility Study for Anatomical Identification by Registration with MicroCT. Ann Biomed Eng 2020; 49:1308-1317. [PMID: 33128180 DOI: 10.1007/s10439-020-02671-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Accepted: 10/21/2020] [Indexed: 11/25/2022]
Abstract
Cochlear implantation consists in electrically stimulating the auditory nerve by inserting an electrode array inside the cochlea, a bony structure of the inner ear. In the absence of any visual feedback, the insertion results in many cases of damages of the internal structures. This paper presents a feasibility study on intraoperative imaging and identification of cochlear structures with high-frequency ultrasound (HFUS). 6 ex-vivo guinea pig cochleae were subjected to both US and microcomputed tomography (µCT) we respectively referred as intraoperative and preoperative modalities. For each sample, registration based on simulating US from the scanner was performed to allow a precise matching between the visible structures. According to two otologists, the procedure led to a target registration error of 0.32 mm ± 0.05. Thanks to referring to a better preoperative anatomical representation, we were able to intraoperatively identify the modiolus, both scalae vestibuli and tympani and deduce the location of the basilar membrane, all of which is of great interest for cochlear implantation. Our main objective is to extend this procedure to the human case and thus provide a new tool for inner ear surgery.
Collapse
Affiliation(s)
- Lucas Lavenir
- LIRMM, University of Montpellier, CNRS, Montpellier, France
| | - Nabil Zemiti
- LIRMM, University of Montpellier, CNRS, Montpellier, France.
| | - Mohamed Akkari
- Department of ENT and Head and Neck Surgery, University Hospital Gui de Chauliac, University of Montpellier, Montpellier, France
| | - Gérard Subsol
- LIRMM, University of Montpellier, CNRS, Montpellier, France
| | - Frédéric Venail
- Department of ENT and Head and Neck Surgery, University Hospital Gui de Chauliac, University of Montpellier, Montpellier, France.,Institute for Neurosciences of Montpellier, INSERM U105, Montpellier, France
| | | |
Collapse
|
7
|
Automatic extraction of vertebral landmarks from ultrasound images: A pilot study. Comput Biol Med 2020; 122:103838. [DOI: 10.1016/j.compbiomed.2020.103838] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 05/12/2020] [Accepted: 05/26/2020] [Indexed: 11/17/2022]
|
8
|
Gueziri HE, Santaguida C, Collins DL. The state-of-the-art in ultrasound-guided spine interventions. Med Image Anal 2020; 65:101769. [PMID: 32668375 DOI: 10.1016/j.media.2020.101769] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Revised: 06/23/2020] [Accepted: 06/25/2020] [Indexed: 02/07/2023]
Abstract
During the last two decades, intra-operative ultrasound (iUS) imaging has been employed for various surgical procedures of the spine, including spinal fusion and needle injections. Accurate and efficient registration of pre-operative computed tomography or magnetic resonance images with iUS images are key elements in the success of iUS-based spine navigation. While widely investigated in research, iUS-based spine navigation has not yet been established in the clinic. This is due to several factors including the lack of a standard methodology for the assessment of accuracy, robustness, reliability, and usability of the registration method. To address these issues, we present a systematic review of the state-of-the-art techniques for iUS-guided registration in spinal image-guided surgery (IGS). The review follows a new taxonomy based on the four steps involved in the surgical workflow that include pre-processing, registration initialization, estimation of the required patient to image transformation, and a visualization process. We provide a detailed analysis of the measurements in terms of accuracy, robustness, reliability, and usability that need to be met during the evaluation of a spinal IGS framework. Although this review is focused on spinal navigation, we expect similar evaluation criteria to be relevant for other IGS applications.
Collapse
Affiliation(s)
- Houssem-Eddine Gueziri
- McConnell Brain Imaging Center, Montreal Neurological Institute and Hospital, Montreal (QC), Canada; McGill University, Montreal (QC), Canada.
| | - Carlo Santaguida
- Department of Neurology and Neurosurgery, McGill University Health Center, Montreal (QC), Canada
| | - D Louis Collins
- McConnell Brain Imaging Center, Montreal Neurological Institute and Hospital, Montreal (QC), Canada; McGill University, Montreal (QC), Canada
| |
Collapse
|
9
|
Koo TK, Crews RL, Kwok WE. In Vivo Measurement of the Human Lumbar Spine Using Magnetic Resonance Imaging to Ultrasound Registration. J Manipulative Physiol Ther 2019; 42:343-352. [PMID: 31255312 DOI: 10.1016/j.jmpt.2019.03.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 03/08/2019] [Accepted: 03/30/2019] [Indexed: 11/18/2022]
Abstract
OBJECTIVE This study aimed to refine a magnetic resonance imaging (MRI)-ultrasound registration (ie, alignment) technique to make noninvasive, nonionizing, 3-dimensional measurement of the lumbar segmental motion in vivo. METHODS Five healthy participants participated in this validation study. We scanned the lumbar region of each participant 5 times using an ultrasound probe while he or she kept a prone lying posture on a plinth. Participant-specific models of L1-L5 were constructed from magnetic resonance (MR) images and aligned with the 3-dimensional ultrasound dataset of each scan using 4 variants of MRI-ultrasound registration approach (simplified intensity-based registration [1] with and [2] without including the transverse processes and their surrounding soft tissues [denoted as TP complex]; and hierarchical intensity-based registration [3] with and [4] without including the TP complex). The robustness and precision of these registration approaches were compared. RESULTS Although all registration approaches converged to a similar solution, excluding the TP complex improved the percentage of successful registration from 92% to 100%. There was no significant difference in the precision among the 4 MRI-ultrasound registration variants. For the simplified intensity-based registration without including the TP complex, average precision at each degree of freedom was 1.33° (flexion-extension), 2.48° (lateral bending), 1.32° (axial rotation), 2.15 mm (left/right), 1.08 mm (anterior-posterior), and 1.16 (superior-inferior), respectively. CONCLUSION Given that using simplified intensity-based MRI-ultrasound registration can substantially streamline the registration process and excluding the TP complex would improve the robustness of the registration, we conclude that this combination is the method of choice for in vivo human applications.
Collapse
Affiliation(s)
- Terry K Koo
- Foot Levelers Biomechanics Research Laboratory, New York Chiropractic College, Seneca, Falls, NY.
| | - Robert L Crews
- Foot Levelers Biomechanics Research Laboratory, New York Chiropractic College, Seneca, Falls, NY
| | - Wingchi E Kwok
- Department of Imaging Sciences, University of Rochester, University of Rochester Center for Advanced Brain Imaging & Neurophysiology, Rochester, NY
| |
Collapse
|
10
|
Toward real-time rigid registration of intra-operative ultrasound with preoperative CT images for lumbar spinal fusion surgery. Int J Comput Assist Radiol Surg 2019; 14:1933-1943. [DOI: 10.1007/s11548-019-02020-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Accepted: 06/24/2019] [Indexed: 10/26/2022]
|
11
|
|
12
|
Masoumi N, Xiao Y, Rivaz H. ARENA: Inter-modality affine registration using evolutionary strategy. Int J Comput Assist Radiol Surg 2018; 14:441-450. [DOI: 10.1007/s11548-018-1897-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Accepted: 12/03/2018] [Indexed: 10/27/2022]
|
13
|
Chan A, Parent E, Lou E. Reconstruction and positional accuracy of 3D ultrasound on vertebral phantoms for adolescent idiopathic scoliosis spinal surgery. Int J Comput Assist Radiol Surg 2018; 14:427-439. [PMID: 30519871 DOI: 10.1007/s11548-018-1894-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Accepted: 11/28/2018] [Indexed: 10/27/2022]
Abstract
PURPOSE Determine the positional, rotational and reconstruction accuracy of a 3D ultrasound system to be used for image registration in navigation surgery. METHODS A custom 3D ultrasound for spinal surgery image registration was developed using Optitrack Prime 13-W motion capture cameras and a SonixTablet Ultrasound System. Temporal and spatial calibration was completed to account for time latencies between the two systems and to ensure accurate motion tracking of the ultrasound transducer. A mock operating room capture volume with a pegboard grid was set up to allow phantoms to be placed at a variety of predetermined positions to validate accuracy measurements. Five custom-designed ultrasound phantoms were 3D printed to allow for a range of linear and angular dimensions to be measured when placed on the pegboard. RESULTS Temporal and spatial calibration was completed with measurement repeatabilities of 0.2 mm and 0.5° after calibration. The mean positional accuracy was within 0.4 mm, with all values within 0.5 mm within the critical surgical regions and 96% of values within 1 mm within the full capture volume. All orientation values were within 1.5°. Reconstruction accuracy was within 0.6 mm and 0.9° for geometrically shaped phantoms and 0.5 and 1.9° for vertebrae-mimicking phantoms. CONCLUSIONS The accuracy of the developed 3D ultrasound system meets the 1 mm and 5° requirements of spinal surgery from this study. Further repeatability studies and evaluation on vertebrae are needed to validate the system for surgical use.
Collapse
Affiliation(s)
- Andrew Chan
- Department of Biomedical Engineering, University of Alberta, 1098 Research Transition Facility, 8308-114 Street, Edmonton, AB, T6G 2V2, Canada
| | - Eric Parent
- Department of Physical Therapy, Faculty of Rehabilitation Medicine, University of Alberta, 2-50 Corbett Hall, Edmonton, AB, T6G2G4, Canada
| | - Edmond Lou
- Department of Biomedical Engineering, University of Alberta, 1098 Research Transition Facility, 8308-114 Street, Edmonton, AB, T6G 2V2, Canada. .,Department of Electrical and Computer Engineering, University of Alberta, Donadeo ICE 11-371, 9211-116 Street, Edmonton, AB, T6G 1H9, Canada.
| |
Collapse
|
14
|
Tümer N, Kok AC, Vos FM, Streekstra GJ, Askeland C, Tuijthof GJM, Zadpoor AA. Three-Dimensional Registration of Freehand-Tracked Ultrasound to CT Images of the Talocrural Joint. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2375. [PMID: 30037099 PMCID: PMC6068753 DOI: 10.3390/s18072375] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 07/09/2018] [Accepted: 07/19/2018] [Indexed: 12/11/2022]
Abstract
A rigid surface⁻volume registration scheme is presented in this study to register computed tomography (CT) and free-hand tracked ultrasound (US) images of the talocrural joint. Prior to registration, bone surfaces expected to be visible in US are extracted from the CT volume and bone contours in 2D US data are enhanced based on monogenic signal representation of 2D US images. A 3D monogenic signal data is reconstructed from the 2D data using the position of the US probe recorded with an optical tracking system. When registering the surface extracted from the CT scan to the monogenic signal feature volume, six transformation parameters are estimated so as to optimize the sum of monogenic signal features over the transformed surface. The robustness of the registration algorithm was tested on a dataset collected from 12 cadaveric ankles. The proposed method was used in a clinical case study to investigate the potential of US imaging for pre-operative planning of arthroscopic access to talar (osteo)chondral defects (OCDs). The results suggest that registrations with a registration error of 2 mm and less is achievable, and US has the potential to be used in assessment of an OCD' arthroscopic accessibility, given the fact that 51% of the talar surface could be visualized.
Collapse
Affiliation(s)
- Nazlı Tümer
- Department of Biomechanical Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD Delft, The Netherlands.
| | - Aimee C Kok
- Orthopaedic Research Center Amsterdam, Academic Medical Centre (AMC), Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
| | - Frans M Vos
- Department of Imaging Science and Technology, Quantitative Imaging Group, Delft University of Technology (TU Delft), Lorentzweg 1, 2628 CJ Delft, The Netherlands.
- Department of Radiology, Academic Medical Centre (AMC), Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
| | - Geert J Streekstra
- Department of Radiology, Academic Medical Centre (AMC), Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
| | | | - Gabrielle J M Tuijthof
- Orthopaedic Research Center Amsterdam, Academic Medical Centre (AMC), Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
- Zuyd University of Applied Sciences, Research Centre Smart Devices, Nieuw Eyckholt 300, 6419 DJ Heerlen, The Netherlands.
| | - Amir A Zadpoor
- Department of Biomechanical Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD Delft, The Netherlands.
| |
Collapse
|
15
|
Improved Surface-Based Registration of CT and Intraoperative 3D Ultrasound of Bones. JOURNAL OF HEALTHCARE ENGINEERING 2018; 2018:2365178. [PMID: 29973976 PMCID: PMC6008887 DOI: 10.1155/2018/2365178] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Revised: 03/09/2018] [Accepted: 04/01/2018] [Indexed: 01/01/2023]
Abstract
The intraoperative registration of preoperative CT volumes is a key process of most computer-assisted orthopedic surgery (CAOS) systems. In this work, is reported a new method for automatic registration of long bones, based on the segmentation of the bone cortical in intraoperative 3D ultrasound images. A bone classifier was developed based on features, obtained from the principal component analysis of the Hessian matrix, of every voxel in an intraoperative ultrasound volume. 3D freehand ultrasound was used for the acquisition of the intraoperative ultrasound volumes. Corresponding bone surface segmentations in ultrasound and preoperative CT imaging were used for the intraoperative registration. Validation on a phantom of the tibia produced encouraging results, with a maximum mean segmentation error of 0.34mm (SD=0.26mm) and a registration accuracy error of 0.64mm (SD=0.49mm).
Collapse
|
16
|
Actuator-Assisted Calibration of Freehand 3D Ultrasound System. JOURNAL OF HEALTHCARE ENGINEERING 2018; 2018:9314626. [PMID: 29854371 PMCID: PMC5954878 DOI: 10.1155/2018/9314626] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Revised: 03/21/2018] [Accepted: 04/11/2018] [Indexed: 11/23/2022]
Abstract
Freehand three-dimensional (3D) ultrasound has been used independently of other technologies to analyze complex geometries or registered with other imaging modalities to aid surgical and radiotherapy planning. A fundamental requirement for all freehand 3D ultrasound systems is probe calibration. The purpose of this study was to develop an actuator-assisted approach to facilitate freehand 3D ultrasound calibration using point-based phantoms. We modified the mathematical formulation of the calibration problem to eliminate the need of imaging the point targets at different viewing angles and developed an actuator-assisted approach/setup to facilitate quick and consistent collection of point targets spanning the entire image field of view. The actuator-assisted approach was applied to a commonly used cross wire phantom as well as two custom-made point-based phantoms (original and modified), each containing 7 collinear point targets, and compared the results with the traditional freehand cross wire phantom calibration in terms of calibration reproducibility, point reconstruction precision, point reconstruction accuracy, distance reconstruction accuracy, and data acquisition time. Results demonstrated that the actuator-assisted single cross wire phantom calibration significantly improved the calibration reproducibility and offered similar point reconstruction precision, point reconstruction accuracy, distance reconstruction accuracy, and data acquisition time with respect to the freehand cross wire phantom calibration. On the other hand, the actuator-assisted modified “collinear point target” phantom calibration offered similar precision and accuracy when compared to the freehand cross wire phantom calibration, but it reduced the data acquisition time by 57%. It appears that both actuator-assisted cross wire phantom and modified collinear point target phantom calibration approaches are viable options for freehand 3D ultrasound calibration.
Collapse
|
17
|
Zhuang B, Rohling R, Abolmaesumi P. Accumulated Angle Factor-Based Beamforming to Improve the Visualization of Spinal Structures in Ultrasound Images. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:210-222. [PMID: 29389653 DOI: 10.1109/tuffc.2017.2781726] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In recent years, ultrasound has been increasingly used to guide needle insertion procedures for spinal anesthesia. The primary anatomical targets are facet joints and epidural spaces. For these procedures, accurate visualization of the spine anatomy is of critical importance. Challenges arising from the interactions between the ultrasound beam and spinal structures including tilt caused by specular reflections, off-axis interference, and reverberations often result in weakened and blurred vertebra surfaces. Previously, adaptive beamforming methods have been proposed to improve the resolution and contrast. However, most of these methods are not specialized for improving the contrast of specular targets like bones. In this paper, we propose an accumulated angle factor (AAF)-based beamforming method customized for bone surface enhancement. This approach applies a Hilbert transform on delay compensated channel data across the receive aperture. The accumulated phase change across the receive aperture is then calculated and utilized as the weight in the beamforming output. We compared our method with classical delay and sum (DAS) beamforming method and adaptive beamforming methods such as Wiener, phase coherence factor (PCF), CF, and generalized CF (GCF) beamforming. In 12 volunteer data sets, the mean contrast ratio between the vertebrae surface and the surrounding tissue for DAS, Wiener, PCF, CF, GCF, and the proposed AAF methods are 0.49, 0.64, 0.82, 0.77, 0.76, and 0.91, respectively. The contrast is significantly improved in the proposed method.
Collapse
|
18
|
Chan A, Aguillon J, Hill D, Lou E. Precision and accuracy of consumer-grade motion tracking system for pedicle screw placement in pediatric spinal fusion surgery. Med Eng Phys 2017; 46:33-43. [PMID: 28602642 DOI: 10.1016/j.medengphy.2017.05.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2016] [Revised: 04/12/2017] [Accepted: 05/16/2017] [Indexed: 11/17/2022]
Abstract
Adolescent idiopathic scoliosis (AIS) is a 3-dimensional spinal deformity involving lateral curvature and axial rotation. Surgical intervention involves insertion of pedicle screws into the spine, requiring accuracies of 1mm and 5° in translation and rotation to prevent neural and vascular complications. While commercial CT-navigation is available, the significant cost, bulk and radiation dose hinders their use in AIS surgery. The objective of this study was to evaluate a commercial-grade Optitrack Prime 13W motion capture cameras to determine if they can achieve adequate accuracy for screw insertion guidance in AIS. Static precision, camera and tracked rigid body configurations, translational and rotational accuracy were investigated. A 1-h camera warm-up time was required to achieve precisions of 0.13mm and 0.10°. A three-camera system configuration with cameras at equal height but staggered depth achieved the best accuracy. A triangular rigid body with 7.9mm markers had superior accuracy. The translational accuracy for motions up to 150mm was 0.25mm while rotational accuracy was 4.9° for rotations in two directions from 0° to 70°. Required translational and rotational accuracies were achieved using this motion capture system as well as being comparable to surgical-grade navigators.
Collapse
Affiliation(s)
- Andrew Chan
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta T6G 2V2, Canada
| | - Janelle Aguillon
- Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9, Canada
| | - Doug Hill
- Department of Surgery, University of Alberta, Edmonton, Alberta T6G 2B7, Canada; Alberta Health Services - Glenrose Rehabilitation Hospital, Edmonton, Alberta T5G 0B7, Canada
| | - Edmond Lou
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta T6G 2V2, Canada; Department of Surgery, University of Alberta, Edmonton, Alberta T6G 2B7, Canada; Alberta Health Services - Glenrose Rehabilitation Hospital, Edmonton, Alberta T5G 0B7, Canada.
| |
Collapse
|
19
|
Abstract
Due to its real-time, non-radiation based three-dimensional (3D) imaging capabilities, ultrasound (US) has been incorporated into various orthopedic procedures. However, imaging artifacts, low signal-to-noise ratio (SNR) and bone boundaries appearing several mm in thickness make the analysis of US data difficult. This paper provides a review about the state-of-the-art bone segmentation and enhancement methods developed for two-dimensional (2D) and 3D US data. First, an overview for the appearance of bone surface response in B-mode data is presented. Then, classification of the proposed techniques in terms of the image information being used is provided. Specifically, the focus is given on segmentation and enhancement of B-mode US data. The review is concluded by discussing future directions of research and additional challenges which need to be overcome in order to make this imaging modality more successful in orthopedics.
Collapse
Affiliation(s)
- Ilker Hacihaliloglu
- Department of Biomedical Engineering, Rutgers University, NJ, USA
- Department of Radiology, Rutgers University Robert Wood Johnson Medical School, NJ, USA
| |
Collapse
|
20
|
Model-based registration of preprocedure MR and intraprocedure US of the lumbar spine. Int J Comput Assist Radiol Surg 2017; 12:973-982. [DOI: 10.1007/s11548-017-1552-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Accepted: 02/27/2017] [Indexed: 10/19/2022]
|
21
|
Hacihaliloglu I. Enhancement of bone shadow region using local phase-based ultrasound transmission maps. Int J Comput Assist Radiol Surg 2017; 12:951-960. [PMID: 28285340 DOI: 10.1007/s11548-017-1556-y] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Accepted: 03/06/2017] [Indexed: 11/26/2022]
Abstract
PURPOSE Ultrasound is increasingly being employed in different orthopedic procedures as an imaging modality for real-time guidance. Nevertheless, low signal-to-noise-ratio and different imaging artifacts continue to hamper the success of ultrasound-based procedures. Bone shadow region is an important feature indicating the presence of bone/tissue interface in the acquired ultrasound data. Enhancement and automatic detection of this region could improve the sensitivity of ultrasound for imaging bone and result in improved guidance for various orthopedic procedures. METHODS In this work, a method is introduced for the enhancement of bone shadow regions from B-mode ultrasound data. The method is based on the combination of three different image phase features: local phase tensor, local weighted mean phase angle, and local phase energy. The combined local phase image features are used as an input to an [Formula: see text] norm-based contextual regularization method which emphasizes uncertainty in the shadow regions. The enhanced bone shadow images are automatically segmented and compared against expert segmentation. RESULTS Qualitative and quantitative validation was performed on 100 in vivo US scans obtained from five subjects by scanning femur and vertebrae bones. Validation against expert segmentation achieved a mean dice similarity coefficient of 0.88. CONCLUSIONS The encouraging results obtained in this initial study suggest that the proposed method is promising enough for further evaluation. The calculated bone shadow maps could be incorporated into different ultrasound bone segmentation and registration approaches as an additional feature.
Collapse
Affiliation(s)
- Ilker Hacihaliloglu
- Department of Biomedical Engineering, Rutgers University, Piscataway, NJ, USA.
- Department of Radiology, Rutgers University Robert Wood Johnson Medical School, New Brunswick, NJ, USA.
| |
Collapse
|
22
|
Zettinig O, Frisch B, Virga S, Esposito M, Rienmüller A, Meyer B, Hennersperger C, Ryang YM, Navab N. 3D ultrasound registration-based visual servoing for neurosurgical navigation. Int J Comput Assist Radiol Surg 2017; 12:1607-1619. [DOI: 10.1007/s11548-017-1536-2] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2016] [Accepted: 02/01/2017] [Indexed: 12/27/2022]
|
23
|
A non-ionizing technique for three-dimensional measurement of the lumbar spine. J Biomech 2016; 49:4073-4079. [DOI: 10.1016/j.jbiomech.2016.10.048] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Revised: 10/25/2016] [Accepted: 10/27/2016] [Indexed: 11/17/2022]
|
24
|
Drouin S, Kochanowska A, Kersten-Oertel M, Gerard IJ, Zelmann R, De Nigris D, Bériault S, Arbel T, Sirhan D, Sadikot AF, Hall JA, Sinclair DS, Petrecca K, DelMaestro RF, Collins DL. IBIS: an OR ready open-source platform for image-guided neurosurgery. Int J Comput Assist Radiol Surg 2016; 12:363-378. [DOI: 10.1007/s11548-016-1478-0] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2016] [Accepted: 08/19/2016] [Indexed: 10/21/2022]
|
25
|
Hierarchical CT to Ultrasound Registration of the Lumbar Spine: A Comparison with Other Registration Methods. Ann Biomed Eng 2016; 44:2887-2900. [DOI: 10.1007/s10439-016-1599-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Accepted: 03/24/2016] [Indexed: 10/22/2022]
|
26
|
Behnami D, Seitel A, Rasoulian A, Anas EMA, Lessoway V, Osborn J, Rohling R, Abolmaesumi P. Joint registration of ultrasound, CT and a shape+pose statistical model of the lumbar spine for guiding anesthesia. Int J Comput Assist Radiol Surg 2016; 11:937-45. [DOI: 10.1007/s11548-016-1369-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2016] [Accepted: 02/26/2016] [Indexed: 11/30/2022]
|
27
|
Ji S, Fan X, Paulsen KD, Roberts DW, Mirza SK, Lollis SS. Intraoperative CT as a registration benchmark for intervertebral motion compensation in image-guided open spinal surgery. Int J Comput Assist Radiol Surg 2015; 10:2009-20. [PMID: 26194485 PMCID: PMC4734629 DOI: 10.1007/s11548-015-1255-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Accepted: 06/30/2015] [Indexed: 02/19/2023]
Abstract
PURPOSE An accurate and reliable benchmark of registration accuracy and intervertebral motion compensation is important for spinal image guidance. In this study, we evaluated the utility of intraoperative CT (iCT) in place of bone-implanted screws as the ground-truth registration and illustrated its use to benchmark the performance of intraoperative stereovision (iSV). METHODS A template-based, multi-body registration scheme was developed to individually segment and pair corresponding vertebrae between preoperative CT and iCT of the spine. Intervertebral motion was determined from the resulting vertebral pair-wise registrations. The accuracy of the image-driven registration was evaluated using surface-to-surface distance error (SDE) based on segmented bony features and was independently verified using point-to-point target registration error (TRE) computed from bone-implanted mini-screws. Both SDE and TRE were used to assess the compensation accuracy using iSV. RESULTS The iCT-based technique was evaluated on four explanted porcine spines (20 vertebral pairs) with artificially induced motion. We report a registration accuracy of 0.57 [Formula: see text] 0.32 mm (range 0.34-1.14 mm) and 0.29 [Formula: see text] 0.15 mm (range 0.14-0.78 mm) in SDE and TRE, respectively, for all vertebrae pooled, with an average intervertebral rotation of [Formula: see text] (range 1.5[Formula: see text]-7.9[Formula: see text]). The iSV-based compensation accuracy for one sample (four vertebrae) was 1.32 [Formula: see text] 0.19 mm and 1.72 [Formula: see text] 0.55 mm in SDE and TRE, respectively, exceeding the recommended accuracy of 2 mm. CONCLUSION This study demonstrates the effectiveness of iCT in place of invasive fiducials as a registration ground truth. These findings are important for future development of on-demand spinal image guidance using radiation-free images such as stereovision and ultrasound on human subjects.
Collapse
Affiliation(s)
- Songbai Ji
- Thayer School of Engineering, Dartmouth College, 14 Engineering Drive, Hanover, NH, 03755, USA.
- Geisel School of Medicine, Dartmouth College, Hanover, NH, 03755, USA.
| | - Xiaoyao Fan
- Thayer School of Engineering, Dartmouth College, 14 Engineering Drive, Hanover, NH, 03755, USA
| | - Keith D Paulsen
- Thayer School of Engineering, Dartmouth College, 14 Engineering Drive, Hanover, NH, 03755, USA
- Dartmouth Hitchcock Medical Center, Lebanon, NH, 03766, USA
| | - David W Roberts
- Geisel School of Medicine, Dartmouth College, Hanover, NH, 03755, USA
- Dartmouth Hitchcock Medical Center, Lebanon, NH, 03766, USA
| | - Sohail K Mirza
- Geisel School of Medicine, Dartmouth College, Hanover, NH, 03755, USA
- Dartmouth Hitchcock Medical Center, Lebanon, NH, 03766, USA
| | - S Scott Lollis
- Geisel School of Medicine, Dartmouth College, Hanover, NH, 03755, USA
- Dartmouth Hitchcock Medical Center, Lebanon, NH, 03766, USA
| |
Collapse
|
28
|
Nagpal S, Abolmaesumi P, Rasoulian A, Hacihaliloglu I, Ungi T, Osborn J, Lessoway VA, Rudan J, Jaeger M, Rohling RN, Borschneck DP, Mousavi P. A multi-vertebrae CT to US registration of the lumbar spine in clinical data. Int J Comput Assist Radiol Surg 2015; 10:1371-81. [DOI: 10.1007/s11548-015-1247-5] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2014] [Accepted: 06/08/2015] [Indexed: 10/23/2022]
|
29
|
Rasoulian A, Seitel A, Osborn J, Sojoudi S, Nouranian S, Lessoway VA, Rohling RN, Abolmaesumi P. Ultrasound-guided spinal injections: a feasibility study of a guidance system. Int J Comput Assist Radiol Surg 2015; 10:1417-25. [DOI: 10.1007/s11548-015-1212-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Accepted: 04/09/2015] [Indexed: 11/25/2022]
|
30
|
Abu Anas EM, Seitel A, Rasoulian A, St John P, Pichora D, Darras K, Wilson D, Lessoway VA, Hacihaliloglu I, Mousavi P, Rohling R, Abolmaesumi P. Bone enhancement in ultrasound using local spectrum variations for guiding percutaneous scaphoid fracture fixation procedures. Int J Comput Assist Radiol Surg 2015; 10:959-69. [PMID: 25847667 DOI: 10.1007/s11548-015-1181-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2015] [Accepted: 03/17/2015] [Indexed: 01/29/2023]
Abstract
PURPOSE The scaphoid bone is the most frequently fractured bone in the wrist. When fracture fixation is indicated, a screw is inserted into the bone either in an open surgical procedure or percutaneously under fluoroscopic guidance. Due to the complex geometry of the wrist, fracture fixation is a challenging task. Fluoroscopic guidance exposes both the patient and the physician to ionizing radiation. Ultrasound-based guidance has been suggested as a real-time, radiation-free alternative. The main challenge of using ultrasound is the difficulty in interpreting the images due to the low contrast and noisy nature of the data. METHODS We propose a bone enhancement method that exploits local spectrum features of the ultrasound image. These features are utilized to design a set of quadrature band-pass filters and subsequently estimate the local phase symmetry, where high symmetry is expected at the bone locations. We incorporate the shadow information below the bone surfaces to further enhance the bone responses. The extracted bone surfaces are then used to register a statistical wrist model to ultrasound volumes, allowing the localization and interpretation of the scaphoid bone in the volumes. RESULTS Feasibility experiments were performed using phantom and in vivo data. For phantoms, we obtain a surface distance error 1.08 mm and an angular deviation from the main axis of the scaphoid bone smaller than 5°, which are better compared to previously presented approaches. CONCLUSION The results are promising for further development of a surgical guidance system to enable accurate anatomy localization for guiding percutaneous scaphoid fracture fixations.
Collapse
|
31
|
Najafi M, Afsham N, Abolmaesumi P, Rohling R. A closed-form differential formulation for ultrasound spatial calibration: single wall phantom. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1079-1094. [PMID: 25701520 DOI: 10.1016/j.ultrasmedbio.2014.11.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2014] [Revised: 10/17/2014] [Accepted: 11/25/2014] [Indexed: 06/04/2023]
Abstract
Calibration is essential in freehand 3-D ultrasound to find the spatial transformation from the image coordinates to the sensor coordinate system. Ease of use, simplicity, precision and accuracy are among the most important factors in ultrasound calibration, especially when aiming to make calibration more reliable for day-to-day clinical use. We introduce a new mathematical framework for the simple and popular single-wall calibration phantom with a plane equation pre-determination step and the use of differential measurements to obtain accurate measurements. The proposed method provides a novel solution for ultrasound calibration that is accurate and easy to perform. This method is applicable to both radiofrequency (RF) and B-mode data, and both linear and curvilinear transducers. For a linear L14-5 transducer, the point reconstruction accuracy (PRA) of reconstructing 370 points is 0.73 ± 0.23 mm using 100 RF images, whereas the triple N-wire PRA is 0.67 ± 0.20 mm using 100 B-mode images. For a curvilinear C5-2 transducer, the PRA using the proposed method is 0.86 ± 0.28 mm on 400 points using 100 RF images, whereas N-wire calibration gives a PRA of 0.80 ± 0.46 mm using 100 B-mode images. Therefore, the accuracy of the proposed variation of the single-wall method using RF data is practically similar to the N-wire method while offering a simpler phantom with no need for accurate design and construction.
Collapse
Affiliation(s)
- Mohammad Najafi
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia, Canada
| | - Narges Afsham
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia, Canada
| | - Purang Abolmaesumi
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia, Canada
| | - Robert Rohling
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia, Canada; Department of Mechanical Engineering, University of British Columbia, Vancouver, British Columbia, Canada.
| |
Collapse
|
32
|
Hacihaliloglu I, Rasoulian A, Rohling RN, Abolmaesumi P. Local phase tensor features for 3-D ultrasound to statistical shape+pose spine model registration. IEEE TRANSACTIONS ON MEDICAL IMAGING 2014; 33:2167-2179. [PMID: 24988590 DOI: 10.1109/tmi.2014.2332571] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Most conventional spine interventions are performed under X-ray fluoroscopy guidance. In recent years, there has been a growing interest to develop nonionizing imaging alternatives to guide these procedures. Ultrasound guidance has emerged as a leading alternative. However, a challenging problem is automatic identification of the spinal anatomy in ultrasound data. In this paper, we propose a local phase-based bone feature enhancement technique that can robustly identify the spine surface in ultrasound images. The local phase information is obtained using a gradient energy tensor filter. This information is used to construct local phase tensors in ultrasound images, which highlight the spine surface. We show that our proposed approach results in a more distinct enhancement of the bone surfaces compared to recently proposed techniques based on monogenic scale-space filters and logarithmic Gabor filters. We also demonstrate that registration accuracy of a statistical shape+pose model of the spine to 3-D ultrasound images can be significantly improved, using the proposed method, compared to those obtained using monogenic scale-space filters and logarithmic Gabor filters.
Collapse
|
33
|
|
34
|
|
35
|
Manbachi A, Cobbold RSC, Ginsberg HJ. Guided pedicle screw insertion: techniques and training. Spine J 2014; 14:165-79. [PMID: 23623511 DOI: 10.1016/j.spinee.2013.03.029] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2011] [Revised: 10/25/2012] [Accepted: 03/07/2013] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT In spinal fusion surgery, the accuracy with which screws are inserted in the pedicle has a direct effect on the surgical outcome. Accurate placement generally involves considerable judgmental skills that have been developed through a lengthy training process. Because the impact of misaligning one or more pedicle screws can directly affect patient safety, a number of navigational and trajectory verification approaches have been described and evaluated in the literature to provide some degree of guidance to the surgeon. PURPOSE To provide a concise review to justify the need and explore the current state of developing navigational or trajectory verification techniques for ensuring proper pedicle screw insertion along with simulation methods for better educating the surgical trainees. STUDY DESIGN Recent literature review. METHODS To justify the need to develop new methods for optimizing pedicle screw paths, we first reviewed some of the recent publications relating to the statistical outcomes for different types of navigation along with the conventional freehand (unassisted) screw insertion. Second, because of the importance of providing improved training in the skill of accurate screw insertion, the training aspects of relevant techniques are considered. The third part is devoted to the description of specific navigational assist methods or trajectory verification techniques and these include computer-assisted navigation, three-dimensional simulations, and also electric impedance and optical and ultrasonic image-guided methods. CONCLUSIONS This article presents an overview of the need and the current status of the guidance methods available for improving the surgical outcomes in spinal fusion procedures. It also describes educational aids that have the potential for reducing the training process.
Collapse
Affiliation(s)
- Amir Manbachi
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, 164 College St, Toronto, Ontario, Canada M5S 3G9
| | - Richard S C Cobbold
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, 164 College St, Toronto, Ontario, Canada M5S 3G9.
| | - Howard J Ginsberg
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, 164 College St, Toronto, Ontario, Canada M5S 3G9; Division of Neurosurgery, St Michael's Hospital, 30 Bond Street, Toronto, Ontario, Canada M5B 1W8
| |
Collapse
|
36
|
Ultrasound-CT registration of vertebrae without reconstruction. Int J Comput Assist Radiol Surg 2012; 7:901-9. [DOI: 10.1007/s11548-012-0771-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2012] [Accepted: 05/31/2012] [Indexed: 10/28/2022]
|
37
|
Bibliography Current World Literature. CURRENT ORTHOPAEDIC PRACTICE 2012. [DOI: 10.1097/bco.0b013e318256e7f2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
38
|
Yan CXB, Goulet B, Chen SJS, Tampieri D, Collins DL. Validation of automated ultrasound-CT registration of vertebrae. Int J Comput Assist Radiol Surg 2011; 7:601-10. [DOI: 10.1007/s11548-011-0666-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2011] [Accepted: 11/08/2011] [Indexed: 10/15/2022]
|