1
|
Xiao YD, Ma C, Liu J, Li HB, Zhou SK, Zhang ZS. Transient severe motion during arterial phase in patients with Gadoxetic acid administration: Can a five hepatic arterial subphases technique mitigate the artifact? Exp Ther Med 2018; 15:3133-3139. [PMID: 29456716 DOI: 10.3892/etm.2018.5760] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Accepted: 01/04/2018] [Indexed: 12/16/2022] Open
Abstract
Gadoxetic acid (Gd-EOB-DTPA) is a hepatocyte-specific magnetic resonance (MR) contrast agent, which has been increasingly used in recent years. However, it has been reported that Gd-EOB-DTPA related transient severe motion (TSM) is sometimes observed during the hepatic arterial phase of MR imaging, which may influence image quality. Since the hepatic arterial phase of contrast enhancement is used for the diagnosis of hepatocellular carcinoma, it is crucial to obtain a decent arterial phase imaging. The present study analyzed motion in patients receiving Gd-EOB-DTPA, comparing a single arterial phase acquisition to a five arterial phase acquisition to determine whether the multiphase acquisition was able to alleviate the TSM-related hepatic arterial MR imaging artifact. It was demonstrated that the single-phase acquisition failed to provide adequate diagnostic image quality in patients with TSM, whereas the multiphase arterial acquisition provided acceptable image quality in 20/22 (90.9%) patients with TSM. In conclusion, the results of the present study demonstrated that multiphase arterial acquisition is superior to single-phase arterial acquisition, mitigating arterial MR imaging artifacts caused by TSM after the administration of Gd-EOB-DTPA.
Collapse
Affiliation(s)
- Yu-Dong Xiao
- Department of Radiology, The Second XiangYa Hospital of Central South University, Changsha, Hunan 410011, P.R. China
| | - Cong Ma
- Department of Radiology, The Second XiangYa Hospital of Central South University, Changsha, Hunan 410011, P.R. China
| | - Jun Liu
- Department of Radiology, The Second XiangYa Hospital of Central South University, Changsha, Hunan 410011, P.R. China
| | - Hua-Bing Li
- Department of Radiology, The Second XiangYa Hospital of Central South University, Changsha, Hunan 410011, P.R. China
| | - Shun-Ke Zhou
- Department of Radiology, The Second XiangYa Hospital of Central South University, Changsha, Hunan 410011, P.R. China
| | - Zi-Shu Zhang
- Department of Radiology, The Second XiangYa Hospital of Central South University, Changsha, Hunan 410011, P.R. China
| |
Collapse
|
2
|
Kurozumi M, Fujinaga Y, Kitou Y, Yamada A, Ohya A, Adachi Y, Tsukahara Y, Nickel MD, Maruyama K, Uehara T, Miyagawa SI, Kadoya M. Evaluation of hemodynamic imaging findings of hypervascular hepatocellular carcinoma: comparison between dynamic contrast-enhanced magnetic resonance imaging using radial volumetric imaging breath-hold examination with k-space-weighted image contrast reconstruction and dynamic computed tomography during hepatic arteriography. Jpn J Radiol 2018; 36:295-302. [PMID: 29327116 DOI: 10.1007/s11604-018-0720-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Accepted: 01/03/2018] [Indexed: 12/22/2022]
Abstract
PURPOSE To compare the visualization of hemodynamic imaging findings of hypervascular hepatocellular carcinoma (HCC) on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using radial volumetric imaging breath-hold examination with k-space-weighted image contrast reconstruction (r-VIBE-KWIC) versus dynamic computed tomography during hepatic arteriography (dyn-CTHA). MATERIALS AND METHODS We retrospectively reviewed the databases of preoperative DCE-MRI using r-VIBE-KWIC, dyn-CTHA, and postoperative pathology of resected specimens. Fourteen patients with 14 hypervascular HCCs underwent both DCE-MRI and dyn-CTHA. The imaging findings of the tumor and adjacent liver parenchyma were assessed on both modalities by two readers. The tumor enhancement time was also compared between the two modalities. RESULTS On DCE-MRI/dyn-CTHA, early staining, peritumoral low-intensity or low-density bands, corona enhancement, and washout of HCC were observed in 14/14 (100%), 10/12 (83%), 11/14 (78%), and 4/14 (29%) patients, respectively. Pathologically, four HCCs with low-density bands on dyn-CTHA had no fibrous capsules. The median tumor enhancement time on DCE-MRI and dyn-CTHA was 24 (9-24) and 23 (8-35) s, respectively. The correlation coefficient between the two groups was 0.762 (P < 0.002). CONCLUSIONS DCE-MRI using r-VIBE-KWIC has diagnostic potential comparable with that of dyn-CTHA in the hemodynamic evaluation of hypervascular HCC except for the washout phenomenon.
Collapse
Affiliation(s)
- Masahiro Kurozumi
- Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | - Yasunari Fujinaga
- Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
| | - Yoshihiro Kitou
- Radiology Division of Shinshu University Hospital, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | - Akira Yamada
- Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | - Ayumi Ohya
- Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | - Yasuo Adachi
- Radiology Division of Shinshu University Hospital, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | - Yoshinori Tsukahara
- Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | | | - Katsuya Maruyama
- DI Research and Collaboration Department, Siemens Healthcare K.K., Shinagawa, Tokyo, Japan
| | - Takeshi Uehara
- Department of Laboratory Medicine, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | - Shin-Ichi Miyagawa
- First Department of Surgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | - Masumi Kadoya
- Radiology Division of Shinshu University Hospital, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| |
Collapse
|
3
|
Radial volumetric imaging breath-hold examination (VIBE) with k-space weighted image contrast (KWIC) for dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI of the liver: advantages over Cartesian VIBE in the arterial phase. Eur Radiol 2014; 24:1290-9. [PMID: 24633374 DOI: 10.1007/s00330-014-3122-0] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2013] [Revised: 01/30/2014] [Accepted: 02/11/2014] [Indexed: 02/06/2023]
Abstract
OBJECTIVES To compare radial volumetric imaging breath-hold examination with k-space weighted image contrast reconstruction (r-VIBE-KWIC) to Cartesian VIBE (c-VIBE) in arterial phase dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (DCE-MRI) of the liver. METHODS We reviewed 53 consecutive DCE-MRI studies performed on a 3-T unit using c-VIBE and 53 consecutive cases performed using r-VIBE-KWIC with full-frame image subset (r-VIBEfull) and sub-frame image subsets (r-VIBEsub; temporal resolution, 2.5-3 s). All arterial phase images were scored by two readers on: (1) contrast-enhancement ratio (CER) in the abdominal aorta; (2) scan timing; (3) artefacts; (4) visualisation of the common, right, and left hepatic arteries. RESULTS Mean abdominal aortic CERs for c-VIBE, r-VIBEfull, and r-VIBEsub were 3.2, 4.3 and 6.5, respectively. There were significant differences between each group (P < 0.0001). The mean score for c-VIBE was significantly lower than that for r-VIBEfull and r-VIBEsub in all factors except for visualisation of the common hepatic artery (P < 0.05). The mean score of all factors except for scan timing for r-VIBEsub was not significantly different from that for r-VIBEfull. CONCLUSIONS Radial VIBE-KWIC provides higher image quality than c-VIBE, and r-VIBEsub features high temporal resolution without image degradation in arterial phase DCE-MRI. KEY POINTS Radial VIBE-KWIC minimised artefact and produced high-quality and high-temporal-resolution images. Maximum abdominal aortic enhancement was observed on sub-frame images of r-VIBE-KWIC. Using r-VIBE-KWIC, optimal arterial phase images were obtained in over 90 %. Using r-VIBE-KWIC, visualisation of the hepatic arteries was improved. A two-reader study revealed r-VIBE-KWIC's advantages over Cartesian VIBE.
Collapse
|