Gaur S, Stein EB, Schneider DK, Masotti M, Davenport MS, George AK, Ellis JH. Gold nanoshells for prostate cancer treatment: evidence for deposition in abdominal organs.
Abdom Radiol (NY) 2024;
49:1929-1939. [PMID:
38376575 DOI:
10.1007/s00261-024-04184-0]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 12/29/2023] [Accepted: 01/03/2024] [Indexed: 02/21/2024]
Abstract
PURPOSE
Gold-silica nanoshell therapy [AuroShells with subsequent focal laser therapy (AuroLase)] is an emerging targeted treatment modality for prostate cancer. We reviewed pre- and post-treatment unenhanced CT imaging to assess for retained gold-silica nanoshells in the abdomen and pelvis.
METHODS
This single-institution retrospective study identified patients in the AuroLase pilot who underwent pre- and post-treatment unenhanced abdominopelvic CT. The attenuation, before and after gold-silica nanoshell administration, of the liver, spleen, pancreas, kidneys, prostate, blood pool, paraspinal musculature, and abnormal lymph nodes were manually measured by two readers. After inter-reader agreement was calculated using intraclass correlation (ICC), a permutation test was used to assess pre- and post-therapy attenuation differences.
RESULTS
Four patients met the inclusion criteria. Mean age was 72.3 ± 5.9 years. Median time interval between pre-treatment CT and treatment, and between treatment and post-treatment CT, was 232 days and 236.5 days, respectively. The two readers' attenuation measurements had very high agreement (ICC = 0.99, p < 0.001). The highest differences in organ attenuation between pre- and post-therapy scans were seen in all four patients in the liver and spleen (liver increased by an average of 28.9 HU, p = 0.010; spleen increased by an average of 63.7 HU, p = 0.012). A single measured lymph node increased by an average of 58.9 HU. In the remainder of the measured sites, the change in attenuation from pre- to post-therapy scans ranged from -0.1 to 3.8 HU (p > 0.05).
CONCLUSION
Increased attenuation of liver and spleen at CT can be an expected finding in patients who have received gold-silica nanoshell therapy.
Collapse