1
|
Vilhjalmsson D, Lepsenyi M, Syk I, Grönberg A, Thorlacius H. Transanal formation of anastomosis using C-REX device is feasible and effective in high anterior resection. Int J Colorectal Dis 2023; 38:127. [PMID: 37173554 PMCID: PMC10182144 DOI: 10.1007/s00384-023-04420-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 04/25/2023] [Indexed: 05/15/2023]
Abstract
PURPOSE C-REX is a novel instrument for creating stapleless colorectal anastomosis by compression. The aim of this study was to evaluate the feasibility and effectiveness of C-REX in open and laparoscopic high anterior resections. METHODS A prospective clinical safety study on 21 patients reconstructed with C-REX colorectal anastomosis following high anterior resection of the sigmoid colon using two different devices for intraabdominal (n = 6) or transanal (n = 15) placement of the anastomotic rings. Any signs of complications were prospectively monitored by a predefined protocol. Anastomotic contact pressure (ACP) was measured via a catheter-based system, and time for evacuation of the anastomotic rings by the natural route was noted. Blood samples were collected daily, and flexible endoscopy was performed postoperatively to examine macroscopic appearance of the anastomoses. RESULTS One of six patients operated with the intraabdominal anastomosis technique with an ACP of 50 mBar had to be reoperated because of anastomotic leakage. None of the 15 patients operated with the transanal technique (5 open and 10 laparoscopic procedures) had anastomotic complications, and their ACP ranged between 145 and 300 mBar. C-REX rings were uneventfully expelled by the natural route in all patients after a median of 10 days. Flexible endoscopy showed well-healed anastomoses without stenosis in 17 patients and a moderate subclinical stricture in one patient. CONCLUSION These results indicate that the novel transanal C-REX device is a feasible and effective method for colorectal anastomosis following high anterior resections, irrespective of open or laparoscopic approach. Moreover, C-REX allows measurement of intraoperative ACP and thereby a quantitative evaluation of the anastomotic integrity.
Collapse
Affiliation(s)
- Dadi Vilhjalmsson
- Department of Clinical Sciences, Section of Surgery, Malmö, Lund University, Malmö, 205 02, Sweden
| | - Mattias Lepsenyi
- Department of Clinical Sciences, Section of Surgery, Malmö, Lund University, Malmö, 205 02, Sweden
| | - Ingvar Syk
- Department of Clinical Sciences, Section of Surgery, Malmö, Lund University, Malmö, 205 02, Sweden
| | - Anders Grönberg
- Section of Development, CarpoNovum, Halmstad, 302 41, Sweden
| | - Henrik Thorlacius
- Department of Clinical Sciences, Section of Surgery, Malmö, Lund University, Malmö, 205 02, Sweden.
| |
Collapse
|
2
|
Oliveira A, Faria S, Gonçalves N, Martins A, Leão P. Surgical approaches to colonic and rectal anastomosis: systematic review and meta-analysis. Int J Colorectal Dis 2023; 38:52. [PMID: 36814011 PMCID: PMC9947093 DOI: 10.1007/s00384-023-04328-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/28/2023] [Indexed: 02/24/2023]
Abstract
PURPOSE Postoperative complications after a colonic and rectal surgery are of significant concern to the surgical community. Although there are different techniques to perform anastomosis (i.e., handsewn, stapled, or compression), there is still no consensus on which technique provides the least number of postoperative problems. The objective of this study is to compare the different anastomotic techniques regarding the occurrence or duration of postoperative outcomes such as anastomotic dehiscence, mortality, reoperation, bleeding and stricture (as primary outcomes), and wound infection, intra-abdominal abscess, duration of surgery, and hospital stay (as secondary outcomes). METHODS Clinical trials published between January 1, 2010, and December 31, 2021, reporting anastomotic complications with any of the anastomotic technique were identified using the MEDLINE database. Only articles that clearly defined the anastomotic technique used, and report at least two of the outcomes defined were included. RESULTS This meta-analysis included 16 studies whose differences were related to the need of reoperation (p < 0.01) and the duration of surgery (p = 0.02), while for the anastomotic dehiscence, mortality, bleeding, stricture, wound infection, intra-abdominal abscess, and hospital stay, no significant differences were found. Compression anastomosis reported the lowest reoperation rate (3.64%) and the handsewn anastomosis the highest (9.49%). Despite this, more time to perform the surgery was required in compression anastomosis (183.47 min), with the handsewn being the fastest technique (139.92 min). CONCLUSIONS The evidence found was not sufficient to demonstrate which technique is most suitable to perform colonic and rectal anastomosis, since the postoperative complications were similar between the handsewn, stapled, or compression techniques.
Collapse
Affiliation(s)
- Ana Oliveira
- Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Braga, 4710-057, Portugal
- ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
- 3B's Research Group, I3Bs - Research Institute on Biomaterials, Biodegradables & Biomimetics; Headquarters of the European Institute of Excellence on Tissue Engineering & Regenerative Medicine, University of Minho, AvePark-Parque de Ciência e Tecnologia, Zona Industrial da Gandra, Barco, Guimarães, 4805-017, Portugal
| | - Susana Faria
- Centre of Mathematics (CMAT), Department of Mathematics, University of Minho, Guimarães, 4800-058, Portugal
| | - Nuno Gonçalves
- Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Braga, 4710-057, Portugal
- ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
| | - Albino Martins
- ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
- 3B's Research Group, I3Bs - Research Institute on Biomaterials, Biodegradables & Biomimetics; Headquarters of the European Institute of Excellence on Tissue Engineering & Regenerative Medicine, University of Minho, AvePark-Parque de Ciência e Tecnologia, Zona Industrial da Gandra, Barco, Guimarães, 4805-017, Portugal
| | - Pedro Leão
- Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Braga, 4710-057, Portugal.
- ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal.
| |
Collapse
|
3
|
Investigating the effects of various suturing parameters on the leakage from the intestinal anastomosis site: finite element analyses. Biocybern Biomed Eng 2019. [DOI: 10.1016/j.bbe.2019.08.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
4
|
Chen M, Cao J, Huang D, Zhang B, Pan L, Zhang Z, Wang Z, Ye Y, Xiu D, Li D, Cai X. End-to-end intestinal anastomosis using a novel biodegradable stent for laparoscopic colonic surgery: a multicenter study. Surg Today 2019; 49:1003-1012. [PMID: 31256255 DOI: 10.1007/s00595-019-01841-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2019] [Accepted: 06/02/2019] [Indexed: 02/06/2023]
Abstract
PURPOSE Our animal studies have demonstrated the safety and feasibility of end-to-end intestinal anastomosis using a stent for laparoscopic colonic surgery. Therefore, we designed a non-inferiority trial to investigate the outcomes of stent anastomosis (SA) vs. those of conventional hand-sewn anastomosis (CA). METHODS A multicenter randomized controlled trial was conducted between December, 2016 and April, 2018. The primary outcome was the healing condition of the anastomoses, evaluated by endoscopy 6 months postoperatively. The secondary outcomes were the anastomotic completion time, anastomotic leak, intestinal obstruction, peritoneal effusion, and bleeding. Quality of life (QOL) was evaluated by questionnaires. RESULTS The subjects of this study were 60 patients, randomly divided into a SA group (n = 30) and a CA group (n = 30). There were no differences in anastomotic healing conditions (P = 1.00). The stent procedure was associated with a significantly shorter anastomosis time than the hand-sewn anastomosis (13.517 ± 4.281 vs. 20.333 ± 2.998 min, respectively; P < 0.001). There were no significant differences in anastomotic leakage, intestinal obstruction, peritoneal effusion, or bleeding between the groups. Questionnaires revealed almost no discrepancy between baseline QOL scores and those assessed 2, 4, 8, 12, and 24 weeks postoperatively in either group. CONCLUSIONS Intestinal anastomosis with a stent is a non-inferior strategy for laparoscopic colonic surgery, which requires less time for the anastomosis.
Collapse
Affiliation(s)
- Mingyu Chen
- Department of General Surgery, Sir Run-Run Shaw Hospital, Zhejiang University, No.3 East Qingchun Road, Hangzhou, 310016, China
- Key Laboratory of Endoscopic Technique Research of Zhejiang Province, Sir Run-Run Shaw Hospital, Zhejiang University, Hangzhou, 310016, China
| | - Jiasheng Cao
- Department of General Surgery, Sir Run-Run Shaw Hospital, Zhejiang University, No.3 East Qingchun Road, Hangzhou, 310016, China
| | - Diyu Huang
- Department of General Surgery, Sir Run-Run Shaw Hospital, Zhejiang University, No.3 East Qingchun Road, Hangzhou, 310016, China
| | - Bin Zhang
- Department of General Surgery, Sir Run-Run Shaw Hospital, Zhejiang University, No.3 East Qingchun Road, Hangzhou, 310016, China
| | - Long Pan
- Department of General Surgery, Sir Run-Run Shaw Hospital, Zhejiang University, No.3 East Qingchun Road, Hangzhou, 310016, China
| | - Zhongtao Zhang
- Department of General Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing, 100032, China
| | - Zhenjun Wang
- Department of Anorectal Surgery, Beijing Chao-yang Hospital, Capital Medical University, Beijing, 100020, China
| | - Yingjiang Ye
- Department of Gastrointestinal Surgery, Peking University People's Hospital, Beijing, 100032, China
| | - Dianrong Xiu
- Department of General Surgery, Peking University Third Hospital, Beijing, 100089, China
| | - Dechuan Li
- Department of Colorectal Surgery, Zhejiang Cancer Hospital, Hangzhou, 310011, China
| | - Xiujun Cai
- Department of General Surgery, Sir Run-Run Shaw Hospital, Zhejiang University, No.3 East Qingchun Road, Hangzhou, 310016, China.
- Key Laboratory of Endoscopic Technique Research of Zhejiang Province, Sir Run-Run Shaw Hospital, Zhejiang University, Hangzhou, 310016, China.
| |
Collapse
|
5
|
Ma F, Ma J, Ma S, Fu S, Zhang Y, Liu H, Lv Y, Wu R, Yan X. A novel magnetic compression technique for small intestinal end-to-side anastomosis in rats. J Pediatr Surg 2019; 54:744-749. [PMID: 30064696 DOI: 10.1016/j.jpedsurg.2018.07.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Revised: 06/15/2018] [Accepted: 07/19/2018] [Indexed: 01/09/2023]
Abstract
BACKGROUND Magnetic compression technology is a safe and convenient digestive tract reconstruction technique in large animals. The purpose of this study was to verify the feasibility of using the micromagnetic ring for construction of small intestinal end-to-side anastomosis in rats. METHODS Thirty male Sprague-Dawley albino rats were randomly divided into two groups: a study group that underwent small intestinal anastomosis with micromagnetic ring and a control group that had hand-sewn anastomosis. The time to construct the anastomosis, survival rate and incidence of complications were compared between the two groups. The anastomotic segments in each group were harvested on day 28 after surgery and investigated. RESULTS The mean anastomosis construction time was significantly lower in the study group than the control group (6.80 ± 1.97 min vs. 16.13 ± 3.29 min, P < 0.05). The survival rate was significantly higher in the study group (93.3%, 14/15) than the control group (66.7%, 10/15; P < 0.05). The incidence of anastomotic leakage [0% (0/15) vs. 6.67% (1/15), P = 1.000] and obstruction [20% (3/15) vs. 13.33% (2/15), P = 0.330] was similar in the study group and control group. The mean burst pressure did not differ significantly between the magnetic compression and hand-sewn anastomosis. In the study group, alignment of the tissue layers was improved and the inflammatory reaction was milder. CONCLUSION Use of a micromagnetic ring for small intestinal end-to-side anastomosis in rats is safe and feasible.
Collapse
Affiliation(s)
- Feng Ma
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, Xi'an, China
| | - Jia Ma
- Department of Surgical Oncology, The Third Affiliated Hospital of Xi'an Jiaotong University (Shaanxi Provincial People's Hospital), Xi'an, China
| | - Sijie Ma
- Qide College, Xi'an Jiaotong University Health Science Center, Xi'an Jiaotong University, Xi'an, China
| | - Shan Fu
- Qide College, Xi'an Jiaotong University Health Science Center, Xi'an Jiaotong University, Xi'an, China
| | - Yanchao Zhang
- Qide College, Xi'an Jiaotong University Health Science Center, Xi'an Jiaotong University, Xi'an, China
| | - Hao Liu
- Qide College, Xi'an Jiaotong University Health Science Center, Xi'an Jiaotong University, Xi'an, China
| | - Yi Lv
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, Xi'an, China
| | - Rongqian Wu
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, Xi'an, China.
| | - Xiaopeng Yan
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, Xi'an, China.
| |
Collapse
|
6
|
Kaska M, Blazej S, Turek Z, Ryska A, Jegorov B, Radochova V, Bezouska J, Paral J. The effect of three different surgical techniques for colon anastomosis on regional postoperative microperfusion: Laser Doppler Flowmetry study in pigs. Clin Hemorheol Microcirc 2018; 68:61-70. [PMID: 29439318 DOI: 10.3233/ch-170297] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
BACKGROUND The optimal surgical approach to reconnecting bowel ends safely after resection is of great importance. OBJECTIVES This project is focused on assessment of the perianastomotic microcirculation quality in the short postoperative period when using three different anastomosis techniques in experimental animal. METHODS The experimental study involved 27 young female domestic pigs divided into three subgroups of 9 animals according to each surgical method of anastomosis construction in the sigmoid colon region: by manual suture, by stapler, or by gluing. Blood microcirculation in the anastomosis region was monitored using Laser Doppler Flowmetry (LDF). Anastomosis healing was evaluated by macroscopic and histological examination. RESULTS Evaluation of the microcirculation in the anastomosis region showed the smallest decrease in perfusion values in animals reconstructed by suturing (Δ= -38.01%). A significantly more profound drop was observed postoperatively after stapling or gluing (Δ= -52.42% and Δ= -59.53%, respectively). All performed anastomoses healed without any signs of tissue and function pathology. CONCLUSIONS Sewing, stapling, and gluing techniques for bowel anastomosis each have a different effect on regional microcirculation during 120 min. postoperatively. Nevertheless, the final results of anastomosis healing were found without of any pathology in all experimental animals managed by above mentioned anastomotic techniques.
Collapse
Affiliation(s)
- Milan Kaska
- Academic Department of Surgery, Medical Faculty, Charles University and Teaching Hospital, Hradec Kralove, Czech Republic
| | - Slavomir Blazej
- Academic Department of Surgery, Medical Faculty, Charles University and Teaching Hospital, Hradec Kralove, Czech Republic
| | - Zdenek Turek
- Department of Anaesthesiology and Intensive Care Medicine, Medical Faculty, Charles University and Teaching Hospital, Hradec Kralove, Czech Republic
| | - Ales Ryska
- Fingerland Department of Pathology, Medical Faculty, Charles University and Teaching Hospital, Hradec Kralove, Czech Republic
| | - Boris Jegorov
- Academic Department of Surgery, Medical Faculty, Charles University and Teaching Hospital, Hradec Kralove, Czech Republic
| | - Vera Radochova
- Academic Department of Military Surgery, University of Defence, Hradec Kralove, Czech Republic
| | - Jan Bezouska
- Academic Department of Surgery, Medical Faculty, Charles University and Teaching Hospital, Hradec Kralove, Czech Republic
| | - Jiri Paral
- Academic Department of Surgery, Medical Faculty, Charles University and Teaching Hospital, Hradec Kralove, Czech Republic.,Academic Department of Military Surgery, University of Defence, Hradec Kralove, Czech Republic
| |
Collapse
|
7
|
Khoorjestan SM, Rouhi G, Toolabi K. An investigation of the effects of suture patterns on mechanical strength of intestinal anastomosis: an experimental study. BIOMED ENG-BIOMED TE 2017; 62:429-437. [PMID: 27639265 DOI: 10.1515/bmt-2016-0103] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2016] [Accepted: 07/27/2016] [Indexed: 11/15/2022]
Abstract
How the distance of sutures from the edge of tissue and the horizontal distance between stitches affect the mechanical strength of anastomosis is investigated. In this study, 180 bovine intestines were used to investigate the optimum pattern in 18 groups by considering a 4, 6, and 8 mm horizontal distance between stitches, and a 3, 5, and 7 mm distance from the edge of tissue with 3-0 Silk and 3-0 PDS sutures to maximize the strength of anastomosis (10 specimens in each group). Also, 80 specimens were used to investigate the maximum effective distance of sutures from the edge of tissue in eight groups of: 3, 5, 7, and 10 mm distance from the edge, with the same type of sutures. Tensile tests with an elongation rate of 5 mm/min were performed for all the groups. Based on the results, the pattern of 7-6 (distance from the edge-distance between stitches) for both 3-0 Silk and 3-0 PDS, 5-6 and 7-4 for 3-0 Silk, and 5-6 and 7-4 for 3-0 PDS can be considered as the best options among 18 different combinations. It was also found that increasing the distance from the edge from 7 mm to 10 mm does not cause a significant difference in mechanical strength. Results can help surgeons to improve the intestinal anastomosis and employ it as an input for automatic suturing devices.
Collapse
|
8
|
Vallance A, Wexner S, Berho M, Cahill R, Coleman M, Haboubi N, Heald RJ, Kennedy RH, Moran B, Mortensen N, Motson RW, Novell R, O'Connell PR, Ris F, Rockall T, Senapati A, Windsor A, Jayne DG. A collaborative review of the current concepts and challenges of anastomotic leaks in colorectal surgery. Colorectal Dis 2017; 19:O1-O12. [PMID: 27671222 DOI: 10.1111/codi.13534] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2016] [Accepted: 07/27/2016] [Indexed: 02/06/2023]
Abstract
The reduction of the incidence, detection and treatment of anastomotic leakage (AL) continues to challenge the colorectal surgical community. AL is not consistently defined and reported in clinical studies, its occurrence is variably reported and its impact on longterm morbidity and health-care resources has received relatively little attention. Controversy continues regarding the best strategies to reduce the risk. Diagnostic tests lack sensitivity and specificity, resulting in delayed diagnosis and increased morbidity. Intra-operative fluorescence angiography has recently been introduced as a means of real-time assessment of anastomotic perfusion and preliminary evidence suggests that it may reduce the rate of AL. In addition, concepts are emerging about the role of the rectal mucosal microbiome in AL and the possible role of new prophylactic therapies. In January 2016 a meeting of expert colorectal surgeons and pathologists was held in London, UK, to identify the ongoing controversies surrounding AL in colorectal surgery. The outcome of the meeting is presented in the form of research challenges that need to be addressed.
Collapse
Affiliation(s)
- A Vallance
- Royal College of Surgeons of England, London, UK
| | - S Wexner
- Cleveland Clinic Florida, Weston, Florida, USA
| | - M Berho
- Cleveland Clinic Florida, Weston, Florida, USA
| | - R Cahill
- University College Dublin, Dublin, Ireland
| | | | - N Haboubi
- University Hospital of South Manchester, Manchester, UK
| | - R J Heald
- Basingstoke and North Hampshire Hospital, Basingstoke, UK
| | | | - B Moran
- Basingstoke and North Hampshire Hospital, Basingstoke, UK
| | | | - R W Motson
- The ICENI Centre, Colchester University Hospital, Colchester, UK
| | - R Novell
- The Royal Free Hospital, London, UK
| | | | - F Ris
- Geneva University Hospitals and Medical School, Geneva, Switzerland
| | - T Rockall
- Royal Surrey County Hospital, Guildford, UK
| | | | - A Windsor
- University College Hospital, London, UK
| | | |
Collapse
|
9
|
Compression versus hand-sewn and stapled anastomosis in colorectal surgery: a systematic review and meta-analysis of randomized controlled trials. Tech Coloproctol 2016; 20:667-76. [PMID: 27554096 DOI: 10.1007/s10151-016-1521-8] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Accepted: 07/04/2016] [Indexed: 12/17/2022]
Abstract
Anastomotic leaks are a feared complication of colorectal resections and novel techniques that have the potential to decrease them are still sought. This study aimed to compare the anastomotic leak rates in patients undergoing compression anastomoses versus hand-sewn or stapled anastomoses. Randomized controlled trials (RCTs) comparing outcomes of compression versus conventional (hand-sewn and stapled) colorectal anastomosis were collected from MEDLINE, Embase and the Cochrane Library. The quality of the RCTs and the potential risk of bias were assessed. Pooled odds ratios (OR) were calculated for categorical outcomes and weighted mean differences for continuous data. Ten RCTs were included, comprising 1969 patients (752 sutured, 225 stapled, and 992 compression anastomoses). Most used the biofragmentable anastomotic ring. There was no significant difference between the two groups in terms of anastomotic leak rates (OR 0.80, 95 % confidence interval (CI) 0.47, 1.37; p = 0.42), stricture (OR 0.54: 95 % CI 0.18, 1.64; p = 0.28) or mortality (OR 0.70; 95 % CI 0.39, 1.26; p = 0.24). Compression anastomosis was associated with an earlier return of bowel function: 1.02 (95 % CI 1.37, 0.66) days earlier (p < 0.001) and a shorter postoperative stay; 1.13 (95 % CI 1.52, 0.74) days shorter (p < 0.001), but significant heterogeneity among studies was observed. There was an increased risk of postoperative bowel obstruction in the compression group (OR 1.87; 95 % CI 1.07, 3.26; p = 0.03). There was no significant difference in wound-related and general complications, or length of surgery. Compression devices do not appear to provide an advantage over conventional techniques in fashioning colorectal anastomoses and are associated with an increased risk of bowel obstruction.
Collapse
|
10
|
KHOORJESTAN SANAZMOSAFER, ROUHI GHOLAMREZA, TOOLABI KARAMOLLAH. EXPERIMENTAL INVESTIGATIONS ON INTESTINAL ANASTOMOSIS — A COMPARISON BETWEEN AUTOMATIC AND HAND SUTURING TECHNIQUES. J MECH MED BIOL 2016. [DOI: 10.1142/s0219519416500561] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
In this research, intestinal anastomosis was compared in hand and automatic suturing. This work is based on two different experiments: The first one is the tensile test with the aim of finding the maximum breaking strength with the elongation rate of 5[Formula: see text]mm/min; and the second one is the fatigue test with a frequency of 0.2[Formula: see text]Hz and the amplitude of 16, 24 and 32[Formula: see text]mm of stretch in each phase to discover the total number of cycles to failure. For this purpose, 42 fresh bovine intestines were used; 21 specimens for the tensile and 21 for the fatigue test. These two tests were compared by two hand sewing techniques: simple continuous and ford interlocking stitches, and one automatic technique, i.e., the lock stitches. Seven samples were examined for each particular technique. The results of the tensile test indicated that the breaking strength of automatic sutured specimens is significantly greater than those of hand sutured specimens ([Formula: see text]). That might be due to the regularity, as the suturing lines by machines are more regular than suturing by hand. In addition, results showed that automatic sutured specimens failed in greater number of cycles than hand sutured specimens in the fatigue test ([Formula: see text]).
Collapse
Affiliation(s)
| | - GHOLAMREZA ROUHI
- Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
| | - KARAMOLLAH TOOLABI
- Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
11
|
Ma L, Cai XJ, Wang HH, Yu YL, Huang DY, Ge GJ, Hu HY, Yu SC. Laparoscopic colonic anastomosis using a degradable stent in a porcine model. World J Gastroenterol 2016; 22:4707-4715. [PMID: 27217702 PMCID: PMC4870077 DOI: 10.3748/wjg.v22.i19.4707] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2016] [Revised: 03/02/2016] [Accepted: 03/14/2016] [Indexed: 02/07/2023] Open
Abstract
AIM: To explore the feasibility and safety of laparoscopic colonic anastomosis using a degradable stent in a porcine model.
METHODS: Twenty Bama mini-pigs were randomly assigned to a stent group (n = 10) and control group (hand-sewn anastomosis, n = 10). The anastomotic completion and operation times were recorded, along with histological examination, postoperative general condition, complications, mortality, bursting pressure, and the average anastomotic circumference (AC).
RESULTS: All pigs survived postoperatively except for one in the stent group that died from ileus at 11 wk postoperatively. The operation and anastomotic completion times of the stent group were significantly shorter than those of the control group (P = 0.004 and P = 0.001, respectively). There were no significant differences in bursting pressure between the groups (P = 0.751). No obvious difference was found between the AC and normal circumference in the stent group, but AC was significantly less than normal circumference in the control group (P = 0.047, P < 0.05). No intestinal leakage and luminal stenosis occurred in the stent group. Histological examination revealed that the stent group presented with lower general inflammation and better healing.
CONCLUSION: Laparoscopic colonic anastomosis with a degradable stent is a simple, rapid, and safe procedure in this porcine model.
Collapse
|
12
|
Lu Z, Peng J, Li C, Wang F, Jiang W, Fan W, Lin J, Wu X, Wan D, Pan Z. Efficacy and safety of a NiTi CAR 27 compression ring for end-to-end anastomosis compared with conventional staplers: A real-world analysis in Chinese colorectal cancer patients. Clinics (Sao Paulo) 2016; 71:264-70. [PMID: 27276395 PMCID: PMC4874270 DOI: 10.6061/clinics/2016(05)04] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Accepted: 02/17/2016] [Indexed: 01/17/2023] Open
Abstract
OBJECTIVES This study aimed to evaluate the safety and efficacy of a new nickel-titanium shape memory alloy compression anastomosis ring, NiTi CAR 27, in constructing an anastomosis for colorectal cancer resection compared with conventional staples. METHODS In total, 234 consecutive patients diagnosed with colorectal cancer receiving sigmoidectomy and anterior resection for end-to-end anastomosis from May 2010 to June 2012 were retrospectively analyzed. The postoperative clinical parameters, postoperative complications and 3-year overall survival in 77 patients using a NiTi CAR 27 compression ring (CAR group) and 157 patients with conventional circular staplers (STA group) were compared. RESULTS There were no statistically significant differences between the patients in the two groups in terms of general demographics and tumor features. A clinically apparent anastomotic leak occurred in 2 patients (2.6%) in the CAR group and in 5 patients (3.2%) in the STA group (p=0.804). These eight patients received a temporary diverting ileostomy. One patient (1.3%) in the CAR group was diagnosed with anastomotic stricture through an electronic colonoscopy after 3 months postoperatively. The incidence of postoperative intestinal obstruction was comparable between the two groups (p=0.192). With a median follow-up duration of 39.6 months, the 3-year overall survival rate was 83.1% in the CAR group and 89.0% in the STA group (p=0.152). CONCLUSIONS NiTi CAR 27 is safe and effective for colorectal end-to-end anastomosis. Its use is equivalent to that of the conventional circular staplers. This study suggests that NiTi CAR 27 may be a beneficial alternative in colorectal anastomosis in Chinese colorectal cancer patients.
Collapse
Affiliation(s)
- Zhenhai Lu
- Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Department of Colorectal Surgery, Guangzhou, P.R., China
| | - Jianhong Peng
- Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Department of Colorectal Surgery, Guangzhou, P.R., China
| | - Cong Li
- Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Department of Colorectal Surgery, Guangzhou, P.R., China
| | - Fulong Wang
- Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Department of Colorectal Surgery, Guangzhou, P.R., China
| | - Wu Jiang
- Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Department of Colorectal Surgery, Guangzhou, P.R., China
| | - Wenhua Fan
- Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Department of Colorectal Surgery, Guangzhou, P.R., China
| | - Junzhong Lin
- Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Department of Colorectal Surgery, Guangzhou, P.R., China
| | - Xiaojun Wu
- Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Department of Colorectal Surgery, Guangzhou, P.R., China
| | - Desen Wan
- Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Department of Colorectal Surgery, Guangzhou, P.R., China
| | - Zhizhong Pan
- Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Department of Colorectal Surgery, Guangzhou, P.R., China
- E-mail:
| |
Collapse
|
13
|
Can a nickel-titanium memory-shape device serve as a substitute for the stapler in gastrointestinal anastomosis? A systematic review and meta-analysis. J Surg Res 2015; 201:82-93. [PMID: 26850188 DOI: 10.1016/j.jss.2015.10.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2015] [Revised: 09/20/2015] [Accepted: 10/08/2015] [Indexed: 02/05/2023]
Abstract
BACKGROUND Recently, a nickel-titanium (NiTi) memory-shape device has been successfully used in gastrointestinal anastomosis. The aim of this study was to investigate the feasibility and safety of the device. METHODS Four databases, reference lists, and the World Health Organization International Clinical Trials Registry Platform were systematically searched for randomized controlled trials assessing the clinical efficacy of a NiTi memory-shape device compared with that of a stapler in gastrointestinal or colorectal anastomosis. RESULTS Seven randomized controlled trials regarding the use of compression anastomosis clips (CACs) were enrolled for meta-analysis. The use of CACs was associated with a significant reduction in hospital duration (mean = -0.88 d; 95% confidence interval [CI], -1.38 to -0.38), the time to flatus (mean = -0.36 d; 95% CI, -0.08 to -0.04), and the start of oral intake (mean = -0.45 d; 95% CI, -0.83 to -0.06), as well as a nonsignificant change in postoperative complications and mortality. These clinical outcomes did not significantly change with the use of compression anastomosis rings. CONCLUSIONS Colonic anastomosis with a CAC is likely to reduce hospital duration, time to flatus, and the start of oral intake without influencing mortality or postoperative complications and may be a safe and preferable choice in colonic anastomosis. Further well-designed trials should be performed to determine the safety and efficacy of the newly developed compression anastomosis ring in both ileocolic and colorectal anastomosis.
Collapse
|
14
|
Compression anastomotic ring-locking procedure (CARP) is a safe and effective method for intestinal anastomoses following left-sided colonic resection. Int J Colorectal Dis 2015; 30:969-75. [PMID: 25989929 DOI: 10.1007/s00384-015-2257-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/12/2015] [Indexed: 02/04/2023]
Abstract
BACKGROUND Compression anastomotic ring-locking procedure (CARP) is a novel procedure for creating colonic anastomoses. The surgical procedure allows perioperative quantification of the compression pressure between the intestinal ends within the anastomosis and postoperative monitoring of the anastomotic integrity. We have recently shown that CARP is a safe and effective method for colonic anastomoses in pigs, and the purpose of the present study was to evaluate CARP for colonic anastomoses in humans. MATERIALS AND METHODS This is a prospective study on 25 patients undergoing elective left-sided colonic resection. Time for evacuation of the anastomotic rings, perioperative compression pressure, and adverse effects were recorded. Postoperative blood samples were collected daily, and flexible sigmoidoscopy was performed 8-12 weeks after surgery to examine the anastomoses. RESULTS Fourteen out of 25 patients underwent CARP. CARP was not used in 11 patients due to advanced tumor disease (two cases) and size restrictions (nine cases). No case of anastomotic leakage, bowel obstruction, or stenosis formation was observed. No device-related perioperative adverse events were noted. The surgical device evacuated spontaneously in all patients by the natural route after a median of 10 days. Perioperative compression pressure ranged between 85 and 280 mBar (median 130 mBar). Flexible sigmoidoscopy revealed smooth anastomoses without signs of pathological inflammation or stenosis in all cases. CONCLUSION Our results indicate that the novel suture-less CARP is a safe and effective method for creating colonic anastomoses. Further studies are warranted in larger patient populations to compare CARP head-on-head with stapled and/or hand-sewn colonic anastomoses.
Collapse
|
15
|
Vilhjalmsson D, Olofsson P, Syk I, Thorlacius H, Grönberg A. The compression anastomotic ring-locking procedure: a novel technique for creating a sutureless colonic anastomosis. Eur Surg Res 2014; 54:139-47. [PMID: 25531546 DOI: 10.1159/000368354] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2014] [Accepted: 09/15/2014] [Indexed: 11/19/2022]
Abstract
BACKGROUND/AIM Compression anastomoses might represent an improvement over traditional hand-sewn or stapled techniques. Herein, we describe a novel concept of sutureless colonic anastomosis named compression anastomotic ring-locking procedure (CARP). MATERIALS AND METHODS The surgical device consists of two anastomotic rings and their associated helping tools, facilitating the placement of the rings into the intestinal ends. Furthermore, four catheters are connected to the surgical device, allowing the evaluation of the anastomosis during and after surgery. A total of 31 pigs underwent a low colocolic anastomosis using the anastomotic rings. The compression pressure was measured perioperatively and up to 96 h after surgery. Anastomotic integrity and morphology were analyzed by use of radiology and histology, respectively. A long-term follow-up was conducted in a subgroup of pigs up to 108 days after surgery when the bursting pressure and stricture formation were examined. RESULTS All animals recovered uneventfully, and macroscopic examination revealed intact anastomoses without signs of pathological inflammation or adhesions. The perioperative compression pressure was inversely proportional to the gap size between the anastomotic rings. For example, an anastomotic gap of 1.5 mm created a colonic anastomosis with a perioperative compression pressure of 91 mbar, which remained constant for up to 48 h and resulted in a markedly increased compression pressure. Contrast infusion via the catheters effectively visualized the anastomoses, and no leakage was detected within the study. The surgical device was spontaneously evacuated from the intestines within 6 days after surgery. Histology showed collagen bridging of the anastomoses already 72 h after surgery. Long-term follow-up (54-108 days) revealed no stricture formation in the anastomoses, and the bursting pressure ranged from 120 to 235 mbar. The majority of bursts (10/12) occurred distant from the anastomoses. CONCLUSION We conclude that the surgical device associated to CARP is safe and efficient for creating colonic anastomoses. Further studies in patients undergoing colorectal surgery are warranted.
Collapse
Affiliation(s)
- Dadi Vilhjalmsson
- Section of Surgery, Department of Clinical Sciences, Lund University, Malmö, Sweden
| | | | | | | | | |
Collapse
|
16
|
Fayek IS. Evaluation of stapled versus hand-sewn techniques for colo- rectal anastomosis after low anterior resection of mid-rectal carcinoma: a study on 50 patients. Asian Pac J Cancer Prev 2014; 15:5427-31. [PMID: 25041013 DOI: 10.7314/apjcp.2014.15.13.5427] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
AIM To evaluate the outcome of stapled versus sutured colo-rectal anastomosis after low anterior resection of mid-rectal carcinoma. PATIENTS AND METHODS A prospective study of fifty patients who underwent colo-rectal anastomosis following low anterior resection (LAR) of T2 mid-rectal cancers at the Egyptian National Cancer Institute during the time period from June 2010 to June 2013 was conducted. Classification was into two groups; a stapled anastomosis group I (25 patients) and a hand-sewn anastomosis group II (25 patients). All operations are evaluated regarding intra-operative complications such as anastomotic line bleeding, visceral injuries or major blood loss. The anastomotic time and operative time are documented for each operation. All patients are evaluated post-operatively for anastomotic leakage (AL), wound infection and ileus. RESULTS The distance of the tumor from the anal verge was 9.6 ± 2.0 cm in group I and 9.9 ± 2.4 cm in group II. The mean operative time was 191.5 ± 16.2 min in the stapled group and 208 ± 18.6 min in the sutured group (p=0.002). The mean anastomotic times were 9.0 ± 1.9 min and 19.7 ± 12.2 min (p=0.001). Anastomotic leakage developed in three (12.0%) patients in the stapled group and in four (16.0%) patients in the sutured group (p=1.000). Post-operative ileus was observed in 3 patients in group I and one patient in group II. Wound infection developed in three (12.0%) patients in the stapled group and four (16.0%) patients in the sutured group (p=1.000). CONCLUSION Colo-rectal anastomosis after low anterior resection for mid rectal carcinoma can be conducted safely either by stapling or hand-sewn techniques; however the stapling technique showed shorter anastomotic and operative times with no significant advantages regarding intra- or post-operative complications or hospital stay.
Collapse
Affiliation(s)
- Ihab Samy Fayek
- Department of Surgical Oncology, National Cancer Institute, Cairo University, Egypt E-mail :
| |
Collapse
|
17
|
Kwag SJ, Kim JG, Kang WK, Lee JK, Oh ST. Niti CAR 27 Versus a Conventional End-to-End Anastomosis Stapler in a Laparoscopic Anterior Resection for Sigmoid Colon Cancer. Ann Coloproctol 2014; 30:77-82. [PMID: 24851217 PMCID: PMC4022756 DOI: 10.3393/ac.2014.30.2.77] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2013] [Accepted: 07/24/2013] [Indexed: 01/04/2023] Open
Abstract
PURPOSE The Niti CAR 27 (ColonRing) uses compression to create an anastomosis. This study aimed to investigate the safety and the effectiveness of the anastomosis created with the Niti CAR 27 in a laparoscopic anterior resection for sigmoid colon cancer. METHODS In a single-center study, 157 consecutive patients who received an operation between March 2010 and December 2011 were retrospectively assessed. The Niti CAR 27 (CAR group, 63 patients) colorectal anastomoses were compared with the conventional double-stapled (CDS group, 94 patients) colorectal anastomoses. Intraoperative, immediate postoperative and 6-month follow-up data were recorded. RESULTS There were no statistically significant differences between the two groups in terms of age, gender, tumor location and other clinical characteristics. One patient (1.6%) in the CAR group and 2 patients (2.1%) in the CDS group experienced complications of anastomotic leakage (P = 0.647). These three patients underwent a diverting loop ileostomy. There were 2 cases (2.1%) of bleeding at the anastomosis site in the CDS group. All patients underwent a follow-up colonoscopy (median, 6 months). One patient in the CAR group experienced anastomotic stricture (1.6% vs. 0%; P = 0.401). This complication was solved by using balloon dilatation. CONCLUSION Anastomosis using the Niti CAR 27 device in a laparoscopic anterior resection for sigmoid colon cancer is safe and feasible. Its use is equivalent to that of the conventional double-stapler.
Collapse
Affiliation(s)
- Seung-Jin Kwag
- Department of Surgery, Gyeongsang National University, Postgraduate School of Medicine, Jinju, Korea
| | - Jun-Gi Kim
- Department of Surgery, The Catholic University of Korea, Seoul St. Mary's Hospital, Seoul, Korea
| | - Won-Kyung Kang
- Department of Surgery, The Catholic University of Korea, Seoul St. Mary's Hospital, Seoul, Korea
| | - Jin-Kwon Lee
- Department of Surgery, The Catholic University of Korea, Seoul St. Mary's Hospital, Seoul, Korea
| | - Seong-Taek Oh
- Department of Surgery, The Catholic University of Korea, Seoul St. Mary's Hospital, Seoul, Korea
| |
Collapse
|
18
|
Dauser B, Braunschmid T, Ghaffari S, Riss S, Stift A, Herbst F. Anastomotic leakage after low anterior resection for rectal cancer: comparison of stapled versus compression anastomosis. Langenbecks Arch Surg 2013; 398:957-64. [PMID: 23943311 DOI: 10.1007/s00423-013-1103-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2013] [Accepted: 07/29/2013] [Indexed: 01/20/2023]
Abstract
PURPOSE Surgical technique and perioperative management in rectal cancer surgery have been substantially improved and standardized during the last decades. However, anastomotic leakage following low anterior resection still is a significant problem. Based on animal experimental data of improved healing of compression anastomosis, we hypothesized that a compression anastomotic device might improve healing rates of the highest-risk anastomoses. METHODS All low anterior resections for rectal cancer performed or directly supervised by the senior author between January 2004 and June 2012 were analyzed. Only patients with a stapled or compression anastomosis located within 6 cm from the anal verge were included. Until December 2008, circular staplers were employed, while since January 2009, a novel compression anastomotic device was used for rectal reconstruction exclusively. RESULTS Out of 197 patients operated for rectal cancer, a total of 96 (34 females, 35.4 %) fulfilled inclusion criteria. Fifty-eight (60.4 %) were reconstructed with circular staplers and 38 (39.6 %) using a compression anastomotic device. Significantly, more laparoscopic procedures were recorded in the compression anastomosis group, but distribution of gender, age, body mass index, American Society of Anaesthesiologists score, rate of preoperative radiotherapy, tumor staging, or stoma diversion rate were similar. Anastomotic leakage was observed in seven cases (7/58, 12.1 %) in the stapled and twice (2/38, 5.3 %) in the compression anastomosis group (p = 0.26). CONCLUSIONS In this series, rectal reconstruction following low anterior resection using a novel compression anastomotic device was safe and (at least) equally effective compared to traditional circular staplers concerning leak rate.
Collapse
Affiliation(s)
- Bernhard Dauser
- Department of Surgery, St John of God Hospital, Johannes von Gott Platz 1, 1020, Vienna, Austria
| | | | | | | | | | | |
Collapse
|
19
|
Kopelman D, Kopelman Y, Peled D, Willenz U, Zmora O, Wasserberg N. Healing of ileocolic nitinol compression anastomosis: a novel porcine model of subtotal colectomy. Surg Innov 2013; 20:570-9. [PMID: 23575914 DOI: 10.1177/1553350613484592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND There are limited large animal models for the research of novel anastomotic technologies. Subtotal colectomy requires the anastomosis of relatively remote segments of the alimentary tract that are different anatomically, histologically, and pose significant physiological challenge. The quest for a foreign material-free anastomotic line reintroduced nitinol compression anastomosis into clinical use in the last decade. OBJECTIVE To evaluate the safety, histological, and physiological parameters of side-to-side ileocolic nitinol compression anastomosis in a newly developed large animal model, mimicking the human subtotal colectomy. INTERVENTION Resection of the entire spiral colon with an ileocolic side-to-side compression anastomosis in 12 animals, compared to resection of a short ileal segment in 6 animals. All anastomoses were constructed by using a novel nitinol-based compression device. The animals were followed up to 30 days postoperatively and were reoperated and sacrificed. RESULTS All 12 animals underwent successful subtotal colectomy with side-to-side nitinol compression anastomosis. No signs of abdominal infection were found. The increase in the colectomized animals' bodyweight over the postoperative course was significantly lower and the animals presented with longer periods of diarrhea. The histopathology revealed minimal inflammation and foreign body reaction with good alignment of the bowel wall layers in both groups. The anastomotic line width was shown to be reduced during the healing course of the compression anastomoses. CONCLUSIONS Side-to-side nitinol compression anastomosis is safe and demonstrates favorable functional and histopathological features. The porcine model of subtotal colectomy can be used for further research of novel anastomotic technologies.
Collapse
Affiliation(s)
- Doron Kopelman
- 1Dept. of surgery B', HaEmek medical center, Faculty of medicine of the Technion, Israel institute of technology
| | | | | | | | | | | |
Collapse
|
20
|
Compression anastomosis ring device in colorectal anastomosis: a review of 1,180 patients. Am J Surg 2013; 205:447-51. [PMID: 23290352 DOI: 10.1016/j.amjsurg.2012.03.013] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2011] [Revised: 02/19/2012] [Accepted: 03/04/2012] [Indexed: 12/22/2022]
Abstract
BACKGROUND The nickel-titanium compression anastomosis ring device (ColonRing, NiTi Surgical Solutions, Netanya, Israel) has been cleared by the Food and Drug Administration in 2006 to construct gastrointestinal anastomoses. We evaluated the anastomotic leak rate after end-to-end anastomosis using the ColonRing device. METHODS Using a multinational (16 countries), multicenter (178 centers) data registry provided by NiTi Surgical Solutions, Netanya, Israel, we retrospectively examined clinical data of patients who underwent elective laparoscopic or open left-sided colectomy and anterior resection from January 2008 to June 2010. RESULTS A total of 1,180 patients underwent end-to-end anastomosis using the ColonRing device during the study period. The overall anastomotic leak rate was 3.22% (38 patients). The median length of hospital stay was 6 days (range 2 to 21 days). The median ring expulsion time was 8 days. The earliest ring expulsion time was 6 days; however, in 1 patient, the ring did not expel. In 4 patients, the anastomosis had to be immediately recreated because of 1 misfiring and 3 incomplete anastomoses. CONCLUSIONS The use of the ColonRing device is feasible and safe and could be considered an alternative technology for end-to-end colorectal anastomosis.
Collapse
|
21
|
Metzger P. [Surgical treatment for rectal tumors]. Magy Seb 2012; 65:129-42. [PMID: 22717967 DOI: 10.1556/maseb.65.2012.3.7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
22
|
Kang J, Park MG, Hur H, Min BS, Lee KY, Kim NK. Safety and efficacy of the NiTi Shape Memory Compression Anastomosis Ring (CAR/ColonRing) for end-to-end compression anastomosis in anterior resection or low anterior resection. Surg Innov 2012; 20:164-70. [PMID: 22696026 DOI: 10.1177/1553350612449073] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
PURPOSE Compression anastomoses may represent an improvement over traditional hand-sewn or stapled techniques. This prospective exploratory study aimed to assess the efficacy and complication rates in patients undergoing anterior resection (AR) or low anterior resection (LAR) anastomosed with a novel end-to-end compression anastomosis ring, the ColonRing. METHODS In all, 20 patients (13 male) undergoing AR or LAR were enrolled to be anastomosed using the NiTi Shape Memory End-to-End Compression Anastomosis Ring (NiTi Medical Technologies Ltd, Netanya, Israel). Demographic, intraoperative, and postoperative data were collected. RESULTS Patients underwent AR (11/20) or LAR using laparoscopy (75%), robotic (10%) surgery, or an open laparotomy (15%) approach, with a median anastomotic level of 14.5 cm (range, 4-25 cm). Defunctioning loop ileostomies were formed in 6 patients for low anastomoses. Surgeons rated the ColonRing device as either easy or very easy to use. One patient developed an anastomotic leakage in the early postoperative period; there were no late postoperative complications. Mean time to passage of first flatus and commencement of oral fluids was 2.5 days and 3.2 days, respectively. Average hospital stay was 12.6 days (range, 8-23 days). Finally, the device was expelled on average 15.3 days postoperatively without difficulty. CONCLUSIONS This is the first study reporting results in a significant number of LAR patients and the first reported experience from South Korea; it shows that the compression technique is surgically feasible, easy to use, and without significant complication rates. A large randomized controlled trial is warranted to investigate the benefits of the ColonRing over traditional stapling techniques.
Collapse
Affiliation(s)
- Jeonghyun Kang
- Yonsei University College of Medicine, Seoul, South Korea
| | | | | | | | | | | |
Collapse
|
23
|
Zbar AP, Nir Y, Weizman A, Rabau M, Senagore A. Compression anastomoses in colorectal surgery: a review. Tech Coloproctol 2012; 16:187-99. [PMID: 22534832 DOI: 10.1007/s10151-012-0825-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2011] [Accepted: 02/28/2012] [Indexed: 12/15/2022]
Abstract
The main serious risks of anastomotic construction in the colon and rectum include dehiscence and stricture formation. There is a resurgence of interest in sutureless anastomoses formed by compression elements since the introduction of shape memory alloy (SMA) systems, which evoke minimal early inflammatory response whilst maintaining anastomotic integrity. Currently, the most commonly used SMA is the nickel-titanium (NiTi) alloy that is highly biocompatible, returning to its pre-deformed stable (austenite) shape under different mechanical and thermal loads for use in humans. Pre-clinical data for shape memory alloy systems in colorectal anastomoses are limited, but it appears to be safe in porcine and canine models with limited leakage and reduced stricture formation. There does not appear to be any difference in tissue biochemistry of inflammatory markers when compared with conventional stapled techniques, although the few studies available show a markedly reduced early inflammatory response at the anastomotic site with the NiTi device. The majority of the clinical data concerning compression anastomoses are derived from the biofragmentable anastomotic ring device. This device has fallen out of use because of reported leaks, instrumental failure and problems with device expulsion. A novel SMA device, the NiTi anastomotic ring, permits construction of a low rectal anastomosis construction during open or laparoscopic procedures. The preliminary data demonstrate a safety comparable to conventional staple technology. This device also provides the potential of benefit of reduced anastomotic inflammation, because the compression ring results in direct serosa-to-serosa (or alternatively serosa-to-muscularis propria) apposition without the persistence of residual foreign material. This type of construction could lead to a reduced incidence of early anastomotic leakage and/or the development of anastomotic stenosis. Randomized clinical trials employing a NiTi arm for elective, emergency and high-risk colorectal anastomoses are required to determine its indications and clinical profile as well as to assess whether such technology may selectively obviate the need for proximal diversion in low colorectal anastomoses.
Collapse
Affiliation(s)
- A P Zbar
- Department of Surgery and Transplantation, Chaim Sheba Medical Center, Sackler Medical School, Tel Aviv University, Tel Aviv, Israel.
| | | | | | | | | |
Collapse
|
24
|
Koo EJ, Choi HJ, Woo JH, Park KJ, Roh YH, Kim KH, Lee HY. Anastomosis by use of compression anastomosis ring (CAR™ 27) in laparoscopic surgery for left-sided colonic tumor. Int J Colorectal Dis 2012; 27:391-6. [PMID: 21909697 DOI: 10.1007/s00384-011-1310-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/30/2011] [Indexed: 02/04/2023]
Abstract
PURPOSE The safety and efficacy of the compression anastomosis ring (CAR™ 27) had been demonstrated by animal studies. This study was designed to evaluate clinical validity of the CAR™ 27 anastomosis in laparoscopic surgery for patients with left-sided colonic neoplasm. METHODS Intracorporeal anastomosis using the CAR™ 27 (CAR group) was performed in 66 patients (male 35; median age, 64.5 years), and short-term results were compared with consecutive 116 patients (male 70; median age, 64 years) where the anastomosis was constructed by double stapling technique using a circular stapler for the same indications (stapled group). RESULTS There were no statistically significant differences between the two groups in terms of gender, age, and distribution of pathologic lesion. The laparoscopic procedures, pathologic diagnosis/stage, and length of operation time and postoperative hospital stay were comparable between the two groups. Conversion rate in the CAR and stapled group was 3% and 6%, respectively. There was no surgical mortality in either group. No intraoperative complications associated with the CAR™ 27 anastomosis were encountered. One patient in the CAR group was complicated by anastomotic leakage and none in the stapled group (p = 0.36). There was intestinal obstruction in two patients, in whom one required re-operation for entrapped small bowel adhesions within pelvis. No patient in either group showed symptomatic anastomotic stricture. CONCLUSIONS The anastomosis using the CAR™ 27 is an innovative technique. The CAR™ 27 anastomosis in patients undergoing laparoscopic colectomy for left-sided colonic tumor proved to be a safe and efficacious alternative to the standard double stapling technique.
Collapse
Affiliation(s)
- Eun-Jung Koo
- Department of Surgery, Dong-A University Medical Center, 3-1 Dongdaeshin-Dong, Seo-Gu, Pusan, 602-715, South Korea
| | | | | | | | | | | | | |
Collapse
|
25
|
Compression anastomoses in colon and rectal surgery with the NiTi ColonRing™. Tech Coloproctol 2011; 16:29-35. [PMID: 22139026 DOI: 10.1007/s10151-011-0794-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2011] [Accepted: 11/18/2011] [Indexed: 12/23/2022]
Abstract
BACKGROUND The aim of this prospective study was to evaluate safety and efficacy of the NiTi ColonRing™ for anastomoses on the colon or rectum. METHODS During the period September 2008-June 2011, anastomosis using the NiTi ColonRing™ was scheduled to be performed on 60 patients (36 females, 24 males/mean aged 67 years), 53 of whom underwent colectomy for cancer and 7 reconstruction after Hartmann's procedure. Application of the device failed in one case due to anatomical reasons. Colorectal resections performed were as follows: Right hemicolectomy (5 patients), left colectomy (2), sigmoidectomy (15) and low anterior resection (31). A follow-up clinic visit after 1 month was planned for all patients. Ten patients among the first 14 had rectosigmoidoscopy at 2-3 months. All cancer patients were scheduled for colonoscopy at 12 months. RESULTS No intraoperative or postoperative bleeding related to the anastomotic technique was recorded. Median hospital stay after surgery was 10.2 days (9-22 days). One patient died on day 13 due to myocardial infarction. Clinically apparent leak was detected in one patient who had undergone reconstruction after Hartmann; the only treatment required was total parenteral nutrition for 12 days. Anastomotic stenosis occurred in another one patient who had undergone reconstruction after Hartmann; it was easily resolved by balloon dilatation. Mild complications were encountered in 23 other patients (39%). Oral feeding started after day 4. Anastomotic rings were expelled naturally within 7-17 days (mean, 9.2 days). A satisfactory anastomosis was revealed in patients examined colonoscopically at 2-3 and 12 months. Mean follow-up was 15.2 months (2-33 months). CONCLUSIONS NiTi ColonRing™ is reliable, safe and efficacious for large bowel anastomoses.
Collapse
|
26
|
Lee JY, Woo JH, Choi HJ, Park KJ, Roh YH, Kim KH, Lee HY. Early experience of the compression anastomosis ring (CAR TM 27) in left-sided colon resection. World J Gastroenterol 2011; 17:4787-92. [PMID: 22147979 PMCID: PMC3229627 DOI: 10.3748/wjg.v17.i43.4787] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2011] [Revised: 06/16/2011] [Accepted: 06/23/2011] [Indexed: 02/06/2023] Open
Abstract
AIM: To evaluate clinical validity of the compression anastomosis ring (CAR™ 27) anastomosis in left-sided colonic resection.
METHODS: A non-randomized prospective data collection was performed for patients undergoing an elective left-sided colon resection, followed by an anastomosis using the CAR™ 27 between November 2009 and January 2011. Eligibility criteria of the use of the CAR™ 27 were anastomoses between the colon and at or above the intraperitoneal rectum. The primary short-term clinical endpoint, rate of anastomotic leakage, and other clinical outcomes, including intra- and postoperative complications, length of operation time and hospital stay, and the ring elimination time were evaluated.
RESULTS: A total of 79 patients (male, 43; median age, 64 years) underwent an elective left-sided colon resection, followed by an anastomosis using the CAR™ 27. Colectomy was performed laparoscopically in 70 patients, in whom two patients converted to open procedure (2.9%). There was no surgical mortality. As an intraoperative complication, total disruption of the anastomosis occurred by premature enforced tension on the proximal segment of the anastomosis in one patient. The ring was removed and another new CAR™ 27 anastomosis was constructed. One patient with sigmoid colon cancer showed postoperative anastomotic leakage after 6 d postoperatively and temporary diverting ileostomy was performed. Exact date of expulsion of the ring could not be recorded because most patients were not aware that the ring had been expelled. No patients manifested clinical symptoms of anastomotic stricture.
CONCLUSION: Short-term evaluation of the CAR™ 27 anastomosis in elective left colectomy suggested it to be a safe and efficacious alternative to the standard hand-sewn or stapling technique.
Collapse
|
27
|
Sutureless Intestinal Anastomosis with a Novel Device of Magnetic Compression Anastomosis. ACTA ACUST UNITED AC 2011; 26:182-9. [DOI: 10.1016/s1001-9294(11)60046-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
28
|
Compression Anastomosis Revisited: Prospective Audit of Short- and Medium-term Outcomes in 62 Rectal Anastomoses. World J Surg 2011; 35:1925-32. [DOI: 10.1007/s00268-011-1135-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|