1
|
Fungal Melanins and Applications in Healthcare, Bioremediation and Industry. J Fungi (Basel) 2021; 7:jof7060488. [PMID: 34207260 PMCID: PMC8235761 DOI: 10.3390/jof7060488] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 06/13/2021] [Accepted: 06/13/2021] [Indexed: 01/01/2023] Open
Abstract
Melanin is a complex multifunctional pigment found in all kingdoms of life, including fungi. The complex chemical structure of fungal melanins, yet to be fully elucidated, lends them multiple unique functions ranging from radioprotection and antioxidant activity to heavy metal chelation and organic compound absorption. Given their many biological functions, fungal melanins present many possibilities as natural compounds that could be exploited for human use. This review summarizes the current discourse and attempts to apply fungal melanin to enhance human health, remove pollutants from ecosystems, and streamline industrial processes. While the potential applications of fungal melanins are often discussed in the scientific community, they are successfully executed less often. Some of the challenges in the applications of fungal melanin to technology include the knowledge gap about their detailed structure, difficulties in isolating melanotic fungi, challenges in extracting melanin from isolated species, and the pathogenicity concerns that accompany working with live melanotic fungi. With proper acknowledgment of these challenges, fungal melanin holds great potential for societal benefit in the coming years.
Collapse
|
2
|
Wilson-Stewart KS, Fontanarosa D, Li D, Drovandi CC, Anderson RK, Trapp JV. Taller staff occupationally exposed to less radiation to the temple in cardiac procedures, but risk higher doses during vascular cases. Sci Rep 2020; 10:16103. [PMID: 32999372 PMCID: PMC7528059 DOI: 10.1038/s41598-020-73101-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Accepted: 09/11/2020] [Indexed: 01/05/2023] Open
Abstract
This study aimed to evaluate the effect of nurse and doctor height on occupational dose to the temple during fluoroscopically guided cardiovascular procedures. Additionally, an evaluation of the relationship between doctor height and table height was performed. Staff exposed during fluoroscopic procedures may be at elevated risk of cardiovascular damage or oncogenesis and have demonstrated a higher incidence of subscapular cataracts. The heads of taller staff may be exposed to reduced levels of radiation due to the increased distance from the area of highest intensity X-ray scatter. Limited research has been performed investigating height as a predictor of head dose to nursing staff. The level of radiation dose at the level of the temple to the doctor (n = 25), scrub (n = 28), and scout nurse (n = 29) was measured in a prospective single-center, observational study using Philips DoseAware badges. Procedural characteristics were recorded for vascular and cardiac cases performed in three dedicated angiography suites. Data were also collected to investigate relationships between doctor height and table height. Data were collected for 1585 cardiac and 294 vascular procedures. Staff height was a statistically significant predictor of temple dose for doctors, scrub, and scout nurses when considering the full data sample. The log temple dose demonstrated an inverse relationship to staff height during cardiac procedures, but a positive relationship for scrub and scout nurses during vascular studies. This observational study has demonstrated that taller staff are exposed to less cranial exposure dose during fluoroscopically guided cardiac examinations but has revealed a positive correlation between height and temple dose during vascular procedures. It was also determined that doctor height was correlated with average procedural table height and that vascular access point influences the choice of table elevation.
Collapse
Affiliation(s)
- Kelly S Wilson-Stewart
- School of Chemistry and Physics, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia. .,Cardiovascular Suites, Greenslopes Private Hospital, Newdegate Street, Greenslopes, Brisbane, QLD, 4120, Australia.
| | - Davide Fontanarosa
- School of Clinical Sciences, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia.,Institute of Health and Biomedical Innovation, Queensland University of Technology, Q Block, 60 Musk Avenue, Kelvin Grove, QLD, 4059, Australia
| | - Dan Li
- School of Mathematical Sciences, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia.,Centre for Data Science, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia.,ARC Centre of Excellence for Mathematical and Statistical Frontiers, The University of Melbourne, Parkville, VIC, 3010, Australia
| | - Chris C Drovandi
- School of Mathematical Sciences, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia.,Centre for Data Science, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia.,ARC Centre of Excellence for Mathematical and Statistical Frontiers, The University of Melbourne, Parkville, VIC, 3010, Australia
| | - Rebecca K Anderson
- Cardiovascular Suites, Greenslopes Private Hospital, Newdegate Street, Greenslopes, Brisbane, QLD, 4120, Australia
| | - Jamie V Trapp
- School of Chemistry and Physics, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia
| |
Collapse
|
3
|
Best practice for the nuclear medicine technologist in CT-based attenuation correction and calcium score for nuclear cardiology. Eur J Hybrid Imaging 2020; 4:11. [PMID: 34191150 PMCID: PMC8218053 DOI: 10.1186/s41824-020-00080-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Accepted: 06/16/2020] [Indexed: 12/12/2022] Open
Abstract
The use of hybrid systems is increasingly growing in Europe and this is progressively important for the final result of diagnostic tests. As an integral part of the hybrid imaging system, computed tomography (CT) plays a crucial role in myocardial perfusion imaging diagnostics. Throughout Europe, a variety of equipment is available and also different university curricula of the nuclear medicine technologist are observed. Hence, the Technologist Committee of the European Association of Nuclear Medicine proposes to identify, through a bibliographic review, the recommendations for best practice in computed tomography applied to attenuation correction and calcium score in myocardial perfusion imaging, which courses in the set of knowledge, skills, and competencies for nuclear medicine technologists. This document aims at providing recommendations for CT acquisition protocols and CT image optimization in nuclear cardiology.
Collapse
|
4
|
Cardiac catheterization real-time dynamic radiation dose measurement to estimate lifetime attributable risk of cancer. PLoS One 2020; 15:e0234461. [PMID: 32544209 PMCID: PMC7297332 DOI: 10.1371/journal.pone.0234461] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Accepted: 05/27/2020] [Indexed: 11/24/2022] Open
Abstract
Cardiac catheterization procedure is the gold standard to diagnose and treat cardiovascular disease. However, radiation safety and cancer risk remain major concerns. This study aimed to real-time dynamic radiation dose measurement to estimate lifetime attributable risk (LAR) of cancer incidence and mortality in operators. Coronary angiography (CA) with percutaneous coronary intervention (PCI), CA, and others (radiofrequency ablation, pacemaker and defibrillator implantation) procedures with different beam directions, were undertaken on x-ray angiography system. A real-time electronic personal dosimeter (EPD) system was used to measure the radiation dose of staff during all procedures. We followed the Biological Effects of Ionizing Radiation (BEIR) VII report to estimate the LAR of all cancer incidence and mortality. Primary operators received radiation dose in CA with PCI, CA, and others procedures were 59.33 ± 95.03 μSv, 39.81 ± 103.85 μSv, and 21.92 ± 37.04 μSv, respectively. As to the assistant operators were 30.03 ± 55.67 μSv, 14.67 ± 14.88 μSv, and 4 μSv, respectively. LAR of all cancer incidences for staffs aged from 18 to 65 are varied from 0.40% for males to 1.50% for females. LAR of all cancer mortality for staffs aged from 18 to 65 are varied from 0.22% for males to 0.83% for females. Our study provided an easy, real-time and dynamic radiation dose measurement to estimate LAR of cancer for staff during the cardiac catheterization procedures. The LAR for all cancer incidence is about twice that for cancer mortality. Although the radiation doses of staff are lower during each procedure, the increased years of service leads to greater radiation risk to the staff.
Collapse
|
5
|
Lopes NB, Almeida IV, Lopes PHS, Vicentini VEP. Radioprotective efficacy of plastic polymer against the toxicogenomic effects of radiopharmaceutical 18F-FDG on human lymphocytes. Radiat Oncol 2020; 15:154. [PMID: 32552900 PMCID: PMC7301467 DOI: 10.1186/s13014-020-01598-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Accepted: 06/11/2020] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND Healthcare workers occupationally exposed to 18F-FDG cannot wear protective equipment, such as lead aprons, since the interaction between high energy radiation (511 keV) and metal increases the dose of radiation absorption. The objective of this study was to evaluate the shielding efficacy of a plastic polymer against the toxicogenomic effects of ionizing radiation in human lymphocytes, using cytokinesis-block micronucleus assays. METHODS Human peripheral blood lymphocytes were isolated from three subjects and cultured under standard conditions. The cultures were exposed to 300 mCi of 18F-FDG at a distance of 10 cm for 10 min, in the absence of shielding or with lead, polymer, and lead + polymer shields. RESULTS Lead shielding was found to increase the number of counts detected by Geiger-Müller radiation monitors as a consequence of the photoelectron effect. Conversely, the lead + polymer shield reduced the number of counts. The lead, polymer, and lead + polymer shields significantly reduced the frequency of micronuclei, nucleoplasmic bridges, and nuclear buds induced by ionizing radiation. Regarding cytotoxicity, only the lead + polymer shield re-established the cell cycle at the level observed for the negative control. CONCLUSIONS Lead aprons that are internally coated with polymer increased the radiological protection of individuals occupationally exposed to 18F-FDG PET/CT, especially during examinations.
Collapse
Affiliation(s)
| | - Igor Vivian Almeida
- Department of Biotechnology, Genetics and Cell Biology, State University of Maringá, Avenida Colombo, 5.790, Bloco H67, Sala 11, Jardim Universitário, Maringá, Paraná, 87020-900, Brazil.
- Federal Rural University of Amazonia, Capitão Poço, Pará, Brazil.
| | | | - Veronica Elisa Pimenta Vicentini
- Department of Biotechnology, Genetics and Cell Biology, State University of Maringá, Avenida Colombo, 5.790, Bloco H67, Sala 11, Jardim Universitário, Maringá, Paraná, 87020-900, Brazil
| |
Collapse
|
6
|
Pires RE, Reis IGN, de Faria ÂRV, Giordano V, Labronici PJ, Belangero WD. The hidden risk of ionizing radiation in the operating room: a survey among 258 orthopaedic surgeons in Brazil. Patient Saf Surg 2020; 14:16. [PMID: 32336990 PMCID: PMC7175580 DOI: 10.1186/s13037-020-00238-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Accepted: 04/03/2020] [Indexed: 11/17/2022] Open
Abstract
Background This study aims to assess orthopaedic surgeon knowledge in Brazil about ionizing radiation and its health implications on surgical teams and patients. Methods A 15-question survey on theoretical and practical concepts of ionizing radiation was administered during the 23rd Brazilian Orthopaedic Trauma Association annual meeting. The survey addressed issues within orthopedic surgery, such as radiation safety concepts, protection, exposure, as well as the participant gender. Participants were either orthopedic surgeons or orthopedic surgery residents working at institutions in Brazil. Results One thousand surveys were distributed at the moment of the meeting registration, and 258 were answered completely (25.8% response rate). Only 5.8% of participants used basic radiation protection equipment; 47.3% used a dosimeter; 2.7% reached the annual maximum permissible radiation dose; 10.5% knew the period of increased risk to fetal gestation; 5.8% knew the maximum permissible radiation dose during pregnancy; 58.5% knew that the hands, eyes, and thyroid are the most exposed areas and at greater risk of radiation-related lesions; 25.2% knew the safe distance from a radiation-emitting tube is 3 m or more; 44.2% knew the safest positioning of the radiation-emitting tube; 25.2% knew that smaller tubes emit greater radiation at the entrance dose to magnify the image; and 55.4% knew that the surgery team receives more scattered radiation in surgical procedures performed on obese patients. Conclusion This study revealed inadequate theoretical and practical knowledge about radiation exposure among orthopaedic surgeons in Brazil. Only a minority of orthopaedic surgeons used basic radiation protection equipment. No significant differences in knowledge were found when comparing all orthopedic surgery specialties. Our findings indicate an urgent need for education to increase knowledge among orthopaedic surgeons about the hazards of ionizing radiation. Personal protection and implementation of the ALARA (as low as reasonably achievable) protocol in daily practice are important behaviors to prevent the harmful effects of ionizing radiation.
Collapse
Affiliation(s)
- Robinson Esteves Pires
- 1Departamento do Aparelho Locomotor, Universidade Federal de Minas Gerais, Av. Prof. Alfredo Balena, 190, Santa Efegênia, Belo Horizonte, MG Brazil
| | - Igor Guedes Nogueira Reis
- 1Departamento do Aparelho Locomotor, Universidade Federal de Minas Gerais, Av. Prof. Alfredo Balena, 190, Santa Efegênia, Belo Horizonte, MG Brazil
| | - Ângelo Ribeiro Vaz de Faria
- 1Departamento do Aparelho Locomotor, Universidade Federal de Minas Gerais, Av. Prof. Alfredo Balena, 190, Santa Efegênia, Belo Horizonte, MG Brazil
| | - Vincenzo Giordano
- Serviço de Ortopedia e Traumatologia Prof. Nova Monteiro, Hospital Municipal Miguel Couto, Rio de Janeiro, RJ Brazil
| | - Pedro José Labronici
- 3Departamento de Ortopedia e Traumatologia, Universidade Federal Fluminense, Niterói, RJ Brazil
| | - William Dias Belangero
- 4Departamento de Ortopedia e Traumatologia, Universidade Estadual de Campinas (Unicamp), Campinas, SP Brazil
| |
Collapse
|