1
|
Kwakman JA, Vos MC, Bruno MJ. Investigation of the efficacy of an innovative endoscope drying and storage method in a simulated ERCP setting. Endosc Int Open 2023; 11:E419-E425. [PMID: 37124714 PMCID: PMC10147503 DOI: 10.1055/a-2017-3872] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 12/30/2022] [Indexed: 05/02/2023] Open
Abstract
Background and study aims Drying after cleaning and disinfection is essential in the reprocessing of endoscopes since microorganisms can grow and form biofilms on wet surfaces. In this experimental non-clinical study, we investigated the efficacy of a novel, fast-drying method when reprocessing duodenoscopes. Methods During a series of 40 tests, three duodenoscopes were exposed to an artificial test soil containing supraphysiological loads of four types of gut microorganisms in a non-clinical ERCP simulation, followed by reprocessing and drying with the PlasmaTYPHOON. Cultures of the distal tip and working channel were acquired immediately after automated decontamination and after drying with the PlasmaTYPHOON. Cobalt chloride paper tests and borescope inspections were used to evaluate drying efficacy. Results Contamination of the working channels dropped from 86.4 % post-decontamination to 33.6 % post-drying, with 94 % of the positive post-drying samples belonging to one duodenoscope. This duodenoscope showed persistent contamination with P. aeruginosa in the working channel. The other two duodenoscopes only showed low levels of P. aeruginosa in post-decontamination channel samples, but not after drying. Cobalt chloride paper tests and borescope inspections revealed good drying efficacy. Conclusions Positive cultures for gut microorganisms were often found in wet endoscopes post-decontamination. The PlasmaTYPHOON is an effective fast-drying method capable of abolishing nearly all remaining microorganisms after decontamination provided no biofilm has developed, even when using a supraphysiological concentration of bacterial load. The clinical use of the PlasmaTYPHOON has the potential to reduce endoscope contamination, the use of wet contaminated endoscopes and therefore the risk of patient infection.
Collapse
Affiliation(s)
- Judith A. Kwakman
- Department of Gastroenterology and Hepatology, Erasmus Medical Center, Rotterdam, the Netherlands
- Department of Medical Microbiology and Infectious Diseases, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Margreet C. Vos
- Department of Medical Microbiology and Infectious Diseases, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Marco J. Bruno
- Department of Gastroenterology and Hepatology, Erasmus Medical Center, Rotterdam, the Netherlands
| |
Collapse
|
2
|
Vitale DS, Kwok KK, Liu QY. Society Guidelines-Where Is the Consensus? Gastrointest Endosc Clin N Am 2020; 30:763-779. [PMID: 32891231 DOI: 10.1016/j.giec.2020.06.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
With reports of ongoing duodenoscope contamination and pathogen transmission despite strict adherence to manufacturer reprocessing instructions, professional societies continue to release updated recommendations. Despite general guideline similarities, there are differences. Although adherence to guidelines does not entirely eliminate pathogen contamination or transmission, it is critical to strictly adhere to updated guidelines for maximum risk reduction. In the United States, the Food and Drug Administration and Centers for Disease Control and Prevention continue to offer updates regarding improved duodenoscope reprocessing techniques and endoscope design. This article critically analyzes currently available national and international duodenoscope reprocessing guidelines.
Collapse
Affiliation(s)
- David S Vitale
- Division of Gastroenterology, Hepatology and Nutrition, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, OH, 45229; Department of Pediatrics, University of Cincinnati College of Medicine, 3230 Eden Avenue, Cincinnati, OH, 45267, USA
| | - Karl K Kwok
- Southern California Kaiser Permanente Medical Group, 1526 North Edgemont Street, 7th floor, Los Angeles, CA 90027, USA. https://twitter.com/GI_Guy
| | - Quin Y Liu
- Department of Medicine and Pediatrics, Digestive Disease Center, Cedars-Sinai Medical Center/David Geffen School of Medicine at UCLA, 8700 Beverly Blvd, Suite 7700, South Tower, Los Angeles, CA 90048, USA.
| |
Collapse
|
3
|
Liu S, Zheng J, Hao L, Yegin Y, Bae M, Ulugun B, Taylor TM, Scholar EA, Cisneros-Zevallos L, Oh JK, Akbulut M. Dual-Functional, Superhydrophobic Coatings with Bacterial Anticontact and Antimicrobial Characteristics. ACS APPLIED MATERIALS & INTERFACES 2020; 12:21311-21321. [PMID: 32023023 DOI: 10.1021/acsami.9b18928] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Bacterial pathogens are responsible for millions of cases of illnesses and deaths each year throughout the world. The development of novel surfaces and coatings that effectively inhibit and prevent bacterial attachment, proliferation, and growth is one of the crucial steps for tackling this global challenge. Herein, we report a dual-functional coating for aluminum surfaces that relies on the controlled immobilization of lysozyme enzyme (muramidase) into interstitial spaces of presintered, nanostructured thin film based on ∼200 nm silica nanoparticles and the sequential chemisorption of an organofluorosilane to the available interfacial areas. The mean diameter of the resultant lysozyme microdomains was 3.1 ± 2.5 μm with an average spacing of 8.01 ± 6.8 μm, leading to a surface coverage of 15.32%. The coating had an overall root-mean-square (rms) roughness of 539 ± 137 nm and roughness factor of 1.50 ± 0.1, and demonstrated static, advancing, and receding water contact angles of 159.0 ± 1.0°, 155.4 ± 0.6°, and 154.4 ± 0.6°, respectively. Compared to the planar aluminum, the coated surfaces produced a 6.5 ± 0.1 (>99.99997%) and 4.0 ± 0.1 (>99.99%) log-cycle reductions in bacterial surfaces colonization against Gram-negative Salmonella Typhimurium LT2 and Gram-positive Listeria innocua, respectively. We anticipate that the implementation of such a coating strategy on healthcare environments and surfaces and food-contact surfaces can significantly reduce or eliminate potential risks associated with various contamination and cross-contamination scenarios.
Collapse
Affiliation(s)
- Shuhao Liu
- Artie McFerrin Department of Chemical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Jeremy Zheng
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Li Hao
- School of Chemistry and Chemical Engineering, Zhongkai University of Agriculture and Engineering, Guangzhou 510408, People's Republic of China
| | - Yagmur Yegin
- Department of Nutrition and Food Science, Texas A&M University, College Station, Texas 77843, United States
| | - Michael Bae
- Artie McFerrin Department of Chemical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Beril Ulugun
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Thomas Matthew Taylor
- Department of Nutrition and Food Science, Texas A&M University, College Station, Texas 77843, United States
| | - Ethan A Scholar
- Artie McFerrin Department of Chemical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Luis Cisneros-Zevallos
- Department of Nutrition and Food Science, Texas A&M University, College Station, Texas 77843, United States
- Department of Horticultural Sciences, Texas A&M University, College Station, Texas 77843, United States
| | - Jun Kyun Oh
- Department of Polymer Science and Engineering, Dankook University, 152 Jukjeon-ro, Suji-gu, Yongin-si, Gyeonggi-do 16890, Republic of Korea
| | - Mustafa Akbulut
- Artie McFerrin Department of Chemical Engineering, Texas A&M University, College Station, Texas 77843, United States
- Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States
| |
Collapse
|
4
|
Santos LCS, Parvin F, Huizer-Pajkos A, Wang J, Inglis DW, Andrade D, Hu H, Vickery K. Contribution of usage to endoscope working channel damage and bacterial contamination. J Hosp Infect 2020; 105:176-182. [PMID: 32169614 DOI: 10.1016/j.jhin.2020.03.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Accepted: 03/04/2020] [Indexed: 12/20/2022]
Abstract
BACKGROUND Biofilm formation has been shown to be associated with damaged areas of endoscope channels. It was hypothesized that the passage of instruments and brushes through endoscope channels during procedures and cleaning contributes to channel damage, bacterial attachment and biofilm formation. AIM To compare surface roughness and bacterial attachment in used and new endoscope channels in vivo and in vitro. METHODS Surface roughness of 10 clinically used (retired) and seven new colonoscope biopsy channels was analysed by a surface profiler. For the in-vitro study, a flexible endoscope biopsy forceps was passed repeatedly through a curved 3.0-mm-diameter Teflon tube 100, 200 and 500 times. Atomic force microscopy was used to determine the degree of inner surface damage. The number of Escherichia coli or Enterococcus faecium attached to the inner surface of the new Teflon tube and the tube with 500 forceps passes in 1 h at 37oC was determined by culture. RESULTS The average surface roughness of the used biopsy channels was found to be 1.5 times greater than that of the new biopsy channels (P=0.03). Surface roughness of Teflon tubes with 100, 200 and 500 forceps passes was 1.05-, 1.12- and 3.2-fold (P=0.025) greater than the roughness of the new Teflon tubes, respectively. The number of E. coli and E. faecium attached to Teflon tubes with 500 forceps passes was 2.9-fold (P=0.021) and 4.3-fold (P=0.004) higher compared with the number of E. coli and E. faecium attached to the new Teflon tubes, respectively. CONCLUSION An association was found between endoscope usage with damage to the biopsy channel and increased bacterial attachment.
Collapse
Affiliation(s)
- L C S Santos
- Surgical Infection Research Group, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, Australia; Ribeirao Preto Nursing School, Sao Paulo University, Ribeirao Preto, Sao Paulo, Brazil
| | - F Parvin
- Surgical Infection Research Group, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| | - A Huizer-Pajkos
- Surgical Infection Research Group, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| | - J Wang
- Surgical Infection Research Group, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| | - D W Inglis
- School of Engineering, Macquarie University, Sydney, Australia
| | - D Andrade
- Ribeirao Preto Nursing School, Sao Paulo University, Ribeirao Preto, Sao Paulo, Brazil
| | - H Hu
- Surgical Infection Research Group, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| | - K Vickery
- Surgical Infection Research Group, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, Australia.
| |
Collapse
|
5
|
Sohn SY, Alfa MJ, Lai R, Tabani Y, Labib ME. Turbulent fluid flow is a novel closed-system sample extraction method for flexible endoscope channels of various inner diameters. J Microbiol Methods 2020; 168:105782. [PMID: 31758953 PMCID: PMC6939870 DOI: 10.1016/j.mimet.2019.105782] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Revised: 11/19/2019] [Accepted: 11/19/2019] [Indexed: 12/22/2022]
Abstract
OVERVIEW Effective sample extraction from endoscope channels is crucial for monitoring manual cleaning adequacy as well as for ensuring optimal sensitivity for culture after disinfection. The objective of this study was to compare the efficacy of Turbulent Fluid Flow (TFF) to Flush (F) or Flush-Brush-Flush (FBF) methods. MATERIALS & METHODS Pseudomonas aeruginosa and Enterococcus faecalis in artificial test soil-2015 (ATS2015) were used as bacterial markers while protein and carbohydrate were the organic markers for biofilm formed inside 3.2-mm and 1.37-mm polytetrafluoroethylene (PTFE) channels. TFF was generated using compressed air and sterile water to provide friction for sample extraction. Extraction for biofilm coated PTFE channels as well as for colonoscope channels perfused with ATS2015 containing 108 CFU/mL P. aeruginosa, E. faecalis and Candida albicans was determined using TFF compared to FBF and F. RESULTS The extraction ratio for P. aeruginosa and E. faecalis from biofilm extracted by TFF compared to the positive control was significantly better than F for 1.37-mm channels (≥0.94 for both bacteria by TFF versus 0.69 to 0.72 by F for P. aeruginosa and E. faecalis, respectively) but not significantly different between TFF and FBF for 3.2-mm channels. F was also ineffective for extraction of protein and carbohydrate from 1.37-mm channels. Extraction efficacy by TFF from inoculated colonoscope channels was >98% for all test markers. CONCLUSIONS The novel TFF method for extraction of samples from colonoscope channels is a more effective method than the existing FBF and F methods.
Collapse
Affiliation(s)
| | - Michelle J Alfa
- Department of Medical Microbiology, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Richard Lai
- NovaFlux Inc., 1 Wall Street Princeton, NJ, USA
| | | | | |
Collapse
|
6
|
Thornhill G, David M. Endoscope-associated infections: A microbiologist's perspective on current technologies. TECHNIQUES IN GASTROINTESTINAL ENDOSCOPY 2019. [DOI: 10.1016/j.tgie.2019.150625] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
7
|
Molloy-Simard V, Lemyre JL, Martel K, Catalone BJ. Elevating the standard of endoscope processing: Terminal sterilization of duodenoscopes using a hydrogen peroxide-ozone sterilizer. Am J Infect Control 2019; 47:243-250. [PMID: 30442443 DOI: 10.1016/j.ajic.2018.09.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 09/07/2018] [Accepted: 09/08/2018] [Indexed: 01/21/2023]
Abstract
BACKGROUND The health care community is increasingly aware of the processing challenges and infection risks associated with duodenoscopes owing to published reports of outbreaks and regulatory recalls. Studies have demonstrated that the current practices are inadequate for consistently producing patient-ready endoscopes. Alternatively, terminal sterilization would offer a greater margin of safety and potentially reduce the risk of patient infection. The purpose of this study was to evaluate the efficacy of a hydrogen peroxide-ozone sterilizer with regulatory clearance for terminal sterilization of duodenoscopes. METHODS AND RESULTS Validation studies were performed under laboratory simulated-use and clinical in-use conditions. The overkill method study demonstrated a reduction of at least 6-log of Geobacillus stearothermophilus spores at half-cycle, providing a sterility assurance level of 10-6. In addition, the sterilizer achieved a 6-log reduction of G stearothermophilus in the presence of inorganic and organic soils in a simulated-use study. The clinical in-use study confirmed that the sterilizer achieved sterilization of patient-soiled duodenoscopes under actual use conditions. CONCLUSIONS Simulated-use and clinical in-use studies demonstrated the efficacy of a hydrogen peroxide-ozone sterilizer for terminal sterilization of duodenoscopes. This offers health care facilities a viable alternative for duodenoscope processing to enhance patient safety as part of a comprehensive infection control strategy.
Collapse
|
8
|
|
9
|
Establishment of a Predictive Model Related to Pathogen Invasion for Infectious Diseases and Its Diagnostic Value in Fever of Unknown Origin. Curr Med Sci 2018; 38:1025-1031. [PMID: 30536065 DOI: 10.1007/s11596-018-1979-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 10/23/2018] [Indexed: 02/07/2023]
Abstract
The present study aimed to establish a list of parameters indicative of pathogen invasion and develop a predictive model to distinguish the etiologies of fever of unknown origin (FUO) into infectious and non-infectious causes. From January 2014 to September 2017, 431 patients with FUO were prospectively enrolled in the study population. This study established a list of 26 variables from the following 4 aspects: host factors, epidemiological factors, behavioral factors, and iatrogenic factors. Predefined predicted variables were included in a multivariate logistic regression analysis to develop a predictive model. The predictive model and the corresponding scoring system were developed using data from the confirmed diagnoses and 9 variables were eventually identified. These factors were incorporated into the predictive model. This model discriminated between infectious and non-infectious causes of FUO with an AUC of 0.72, sensitivity of 0.71, and specificity of 0.63. The predictive model and corresponding scoring system based on factors concerning pathogen invasion appear to be reliable screening tools to discriminate between infectious and non-infectious causes of FUO.
Collapse
|
10
|
Johani K, Hu H, Santos L, Schiller S, Deva A, Whiteley G, Almatroudi A, Vickery K. Determination of bacterial species present in biofilm contaminating the channels of clinical endoscopes. Infect Dis Health 2018. [DOI: 10.1016/j.idh.2018.06.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
11
|
McCafferty CE, Aghajani MJ, Abi-Hanna D, Gosbell IB, Jensen SO. An update on gastrointestinal endoscopy-associated infections and their contributing factors. Ann Clin Microbiol Antimicrob 2018; 17:36. [PMID: 30314500 PMCID: PMC6182826 DOI: 10.1186/s12941-018-0289-2] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Accepted: 10/06/2018] [Indexed: 11/10/2022] Open
Abstract
INTRODUCTION During clinical use, gastrointestinal endoscopes are grossly contaminated with patient's native flora. These endoscopes undergo reprocessing to prevent infectious transmission upon future use. Endoscopy-associated infections and outbreaks have been reported, with a recent focus on the transmission of multi-drug resistant organisms. This review aims to provide an update on endoscopy-associated infections, and the factors contributing to their occurrence. METHODS PubMed, ScienceDirect, and CINAHL were searched for articles describing gastrointestinal endoscopy-associated infections and outbreaks published from 2008 to 2018. Factors contributing to their occurrence, and the outcomes of each outbreak were also examined. RESULTS This review found 18 articles, 16 of which described duodenoscope-associated infections, and the remaining two described colonoscope- and gastroscope-associated infection respectively. Outbreaks were reported from the United States, France, China, Germany, the Netherlands and the United Kingdom. The causative organisms reported were Klebsiella pneumoniae, Pseudomonas aeruginosa, Escherichia coli and Salmonella enteritidis. CONCLUSIONS A number of factors, including lapses in reprocessing, biofilm formation, endoscope design issues and endoscope damage, contribute to gastrointestinal endoscopy associated infection. Methods of improving endoscope reprocessing, screening for contamination and evaluating endoscope damage may be vital to preventing future infections and outbreaks.
Collapse
Affiliation(s)
- Charles Eugenio McCafferty
- Ingham Institute for Applied Medical Research, 1 Campbell Street, Sydney, NSW, 2560, Australia. .,Western Sydney University, School of Medicine, Sydney, 2560, Australia.
| | - Marra Jai Aghajani
- Ingham Institute for Applied Medical Research, 1 Campbell Street, Sydney, NSW, 2560, Australia.,Western Sydney University, School of Medicine, Sydney, 2560, Australia
| | - David Abi-Hanna
- Department of Gastroenterology and Hepatology, Liverpool Hospital, Sydney, 2170, Australia.,School of Medicine, University of New South Wales, Sydney, 2033, Australia
| | | | - Slade Owen Jensen
- Ingham Institute for Applied Medical Research, 1 Campbell Street, Sydney, NSW, 2560, Australia.,Western Sydney University, School of Medicine, Sydney, 2560, Australia
| |
Collapse
|
12
|
McCafferty CE, Abi-Hanna D, Aghajani MJ, Micali GT, Lockart I, Vickery K, Gosbell IB, Jensen SO. The validity of adenosine triphosphate measurement in detecting endoscope contamination. J Hosp Infect 2018; 100:e142-e145. [PMID: 30092293 DOI: 10.1016/j.jhin.2018.08.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Accepted: 08/01/2018] [Indexed: 10/28/2022]
Abstract
BACKGROUND Endoscopic procedures are vital to gastrointestinal disease diagnosis and management, but risk infection transmission. In Australia, endoscopes undergo monthly-to-quarterly microbiological testing, to prevent patient infection. Endoscopes are used more frequently, meaning contamination may not be detected by this surveillance before infection transmission occurs. AIM To evaluate the use of adenosine triphosphate (ATP) measurement, alongside standard microbiological cultures, in detecting endoscope contamination before high-level disinfection. Using these results, we also aimed to confirm the efficacy of manual cleaning in reducing levels of ATP and cfu/mL. METHODS Seventeen in-clinical-use gastroscopes and 24 in-clinical-use colonoscopes from the Liverpool Hospital Endoscopy unit were sampled across three separate cleaning stages before high-level disinfection. Colony counts and ATP measurements were then performed on these samples. FINDINGS The correlation between the cfu/mL and RLU of samples collected from colonoscopes was 0.497 (95% confidence interval: 0.28-0.66; P < 0.0001). The correlation between cfu/mL and RLU for samples collected from gastroscopes was 0.377 (0.08-0.61; P = 0.0138). RLU and cfu/mL values were shown to fall significantly (P < 0.005) following precleaning and manual cleaning. CONCLUSION There was a significant correlation between ATP and cfu/mL measured from samples collected before high-level disinfection. Precleaning and manual cleaning were shown to reduce ATP and microbiological load significantly. ATP measurement can be performed within minutes with little training and produces results that are easy to interpret. These findings warrant further research on the utility of ATP measurement as a screening tool for detecting endoscope contamination after high-level disinfection.
Collapse
Affiliation(s)
- C E McCafferty
- Ingham Institute for Applied Medical Research, Sydney, NSW, Australia; Western Sydney University, School of Medicine, Sydney, NSW, Australia.
| | - D Abi-Hanna
- Liverpool Hospital, Department of Gastroenterology and Hepatology, Sydney, NSW, Australia; University of New South Wales, School of Medicine, Sydney, NSW, Australia
| | - M J Aghajani
- Ingham Institute for Applied Medical Research, Sydney, NSW, Australia; Western Sydney University, School of Medicine, Sydney, NSW, Australia
| | - G T Micali
- Ingham Institute for Applied Medical Research, Sydney, NSW, Australia; Western Sydney University, School of Medicine, Sydney, NSW, Australia
| | - I Lockart
- Liverpool Hospital, Department of Gastroenterology and Hepatology, Sydney, NSW, Australia
| | - K Vickery
- Macquarie University, Australian School of Advanced Medicine, Sydney, NSW, Australia
| | - I B Gosbell
- Ingham Institute for Applied Medical Research, Sydney, NSW, Australia; Western Sydney University, School of Medicine, Sydney, NSW, Australia
| | - S O Jensen
- Ingham Institute for Applied Medical Research, Sydney, NSW, Australia; Western Sydney University, School of Medicine, Sydney, NSW, Australia
| |
Collapse
|
13
|
Kozarek RA. Integration of research into endoscopic practice. Gastrointest Endosc 2018; 88:390-392. [PMID: 29921440 DOI: 10.1016/j.gie.2018.04.2336] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Accepted: 04/08/2018] [Indexed: 02/08/2023]
Affiliation(s)
- Richard A Kozarek
- Digestive Disease Institute, Virginia Mason Medical Center, and University of Washington, Seattle, Washington
| |
Collapse
|
14
|
Mallette KI, Pieroni P, Dhalla SS. Bacterial presence on flexible endoscopes vs time since disinfection. World J Gastrointest Endosc 2018; 10:51-55. [PMID: 29375742 PMCID: PMC5769004 DOI: 10.4253/wjge.v10.i1.51] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2017] [Revised: 09/27/2017] [Accepted: 11/10/2017] [Indexed: 02/06/2023] Open
Abstract
AIM To correlate the length of endoscope hang time and number of bacteria cultured prior to use.
METHODS Prospectively, we cultured specimens from 19 gastroscopes, 24 colonoscopes and 5 side viewing duodenoscopes during the period of 2011 to 2015. A total of 164 results had complete data denoting date of cleansing, number of days stored and culture results. All scopes underwent initial cleaning in the endoscopy suite utilizing tap water, and then manually cleaned and flushed. High level disinfection was achieved with a Medivator© DSD (Medivator Inc., United States) automated endoscope reprocessor following manufacturer instructions, with Glutacide® (Pharmax Limited, Canada), a 2% glutaraldehyde solution. After disinfection, all scopes were stored in dust free, unfiltered commercial cabinets for up to 7 d. Prior to use, all scopes were sampled and plated on sheep blood agar for 48 h; the colony count was obtained from each plate. The length of endoscope hang time and bacterial load was analyzed utilizing unpaired t-tests. The overall percentage of positive and negative cultures for each type of endoscope was also calculated.
RESULTS All culture results were within the acceptable range (less than 200 cfu/mL). One colonoscope cultured 80 cfu/mL after hanging for 1 d, which was the highest count. ERCP scopes cultured at most 10 cfu, this occurred after 2 and 7 d, and gastroscopes cultured 50 cfu/mL at most, at 1 d. Most cultures were negative for growth, irrespective of the length of hang time. Furthermore, all scopes, with the exception of one colonoscope which had two positive cultures (each of 10 cfu/mL), had at most one positive culture. There was no significant difference in the number of bacteria cultured after 1 d compared to 7 d when all scopes were combined (day 2: P = 0.515; day 3: P = identical; day 4: P = 0.071; day 5: P = 0.470; day 6: P = 0.584; day 7: P = 0.575). There was also no significant difference in the number of bacteria cultured after 1 day compared to 7 d for gastroscopes (day 2: P = 0.895; day 3: P = identical; day 4: P = identical; day 5: P = 0.893; day 6: P = identical; day 7: P = 0.756), colonoscopes (day 2: P = 0.489; day 4: P = 0.493; day 5: P = 0.324; day 6: P = 0.526; day 7: P = identical), or ERCP scopes (day 2: P = identical; day 7: P = 0.685).
CONCLUSION There is no correlation between hang time and bacterial load. Endoscopes do not need to be reprocessed if reused within a period of 7 d.
Collapse
Affiliation(s)
- Katlin I Mallette
- Max Rady College of Medicine, University of Manitoba, Winnipeg, Manitoba R3E 3P5, Canada
| | - Peter Pieroni
- Diagnostic Services of Manitoba, Westman Laboratory, Department of Microbiology, Brandon Regional Health Centre, Brandon, Manitoba R7A 7H8, Canada
| | - Sonny S Dhalla
- Max Rady College of Medicine, University of Manitoba, Winnipeg, Manitoba R3E 3P5, Canada
- Gastrointestinal Endoscopy Unit, Brandon Regional Health Centre, Brandon, Manitoba R7A 2B3, Canada
| |
Collapse
|
15
|
Alfa MJ, Singh H, Duerksen DR, Schultz G, Reidy C, DeGagne P, Olson N. Improper positioning of the elevator lever of duodenoscopes may lead to sequestered bacteria that survive disinfection by automated endoscope reprocessors. Am J Infect Control 2018; 46:73-75. [PMID: 28918989 DOI: 10.1016/j.ajic.2017.07.021] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2017] [Revised: 07/22/2017] [Accepted: 07/23/2017] [Indexed: 10/18/2022]
Abstract
BACKGROUND Some outbreaks associated with contaminated duodenoscopes have been attributed to biofilm formation. The objective of this study was to determine whether bacteria within an organic matrix could survive if the elevator lever was improperly positioned in the automated endoscope reprocessor (AER) after 1 round of reprocessing. METHODS Duodenoscope lever cavities with an open or sealed elevator wire channel were inoculated with 6-7 Log10 of both Escherichia coli and Enterococcus faecalis in ATS2015 (Healthmark Industries, Fraser, MI) and dried for 2 hours. The duodenoscopes with the lever in the horizontal position were processed through 2 makes of AERs. The cavity was sampled using a flush-brush-flush method to determine the quantity of surviving bacteria. RESULTS E faecalis (range, 21-6 Log10 CFU) and E coli (range, 0-3 Log10 CFU) survived disinfection of sealed or unsealed elevator wire channel duodenoscopes in 2 different AERs with and without cleaning cycles. CONCLUSION If bacteria in organic residue are under the improperly positioned lever, then just 1 round of use is sufficient for bacteria to survive both liquid chemical sterilization and liquid chemical HLD regardless of whether or not the AER had a cleaning cycle.
Collapse
|
16
|
Alfa MJ, Singh H, Nugent Z, Duerksen D, Schultz G, Reidy C, DeGagne P, Olson N. Sterile Reverse Osmosis Water Combined with Friction Are Optimal for Channel and Lever Cavity Sample Collection of Flexible Duodenoscopes. Front Med (Lausanne) 2017; 4:191. [PMID: 29164124 PMCID: PMC5681997 DOI: 10.3389/fmed.2017.00191] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Accepted: 10/23/2017] [Indexed: 11/13/2022] Open
Abstract
Introduction Simulated-use buildup biofilm (BBF) model was used to assess various extraction fluids and friction methods to determine the optimal sample collection method for polytetrafluorethylene channels. In addition, simulated-use testing was performed for the channel and lever cavity of duodenoscopes. Materials and methods BBF was formed in polytetrafluorethylene channels using Enterococcus faecalis, Escherichia coli, and Pseudomonas aeruginosa. Sterile reverse osmosis (RO) water, and phosphate-buffered saline with and without Tween80 as well as two neutralizing broths (Letheen and Dey-Engley) were each assessed with and without friction. Neutralizer was added immediately after sample collection and samples concentrated using centrifugation. Simulated-use testing was done using TJF-Q180V and JF-140F Olympus duodenoscopes. Results Despite variability in the bacterial CFU in the BBF model, none of the extraction fluids tested were significantly better than RO. Borescope examination showed far less residual material when friction was part of the extraction protocol. The RO for flush-brush-flush (FBF) extraction provided significantly better recovery of E. coli (p = 0.02) from duodenoscope lever cavities compared to the CDC flush method. Discussion and conclusion We recommend RO with friction for FBF extraction of the channel and lever cavity of duodenoscopes. Neutralizer and sample concentration optimize recovery of viable bacteria on culture.
Collapse
Affiliation(s)
- Michelle J Alfa
- St. Boniface Research Centre, Winnipeg, MB, Canada.,Department of Medical Microbiology, University of Manitoba, Winnipeg, MB, Canada
| | - Harminder Singh
- Department of Internal Medicine, University of Manitoba, Winnipeg, MB, Canada
| | - Zoann Nugent
- Department of Internal Medicine, University of Manitoba, Winnipeg, MB, Canada
| | - Donald Duerksen
- Department of Internal Medicine, University of Manitoba, Winnipeg, MB, Canada
| | - Gale Schultz
- Winnipeg Regional Health Authority, Winnipeg, MB, Canada
| | | | | | - Nancy Olson
- St. Boniface Research Centre, Winnipeg, MB, Canada
| |
Collapse
|
17
|
Alfa MJ, Ribeiro MM, da Costa Luciano C, Franca R, Olson N, DeGagne P, Singh H. A novel polytetrafluoroethylene-channel model, which simulates low levels of culturable bacteria in buildup biofilm after repeated endoscope reprocessing. Gastrointest Endosc 2017; 86:442-451.e1. [PMID: 28551023 DOI: 10.1016/j.gie.2017.05.014] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Accepted: 05/11/2017] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND AIMS Clinical studies have shown variable culture results from flexible endoscope channels possibly because of low levels of bacteria that are difficult to extract. The aim of this study was to develop a simulated-use buildup biofilm (BBF) model that mimics low levels of viable bacteria after repeated rounds of aldehyde fixation and accumulation. METHODS New endoscope channels were exposed to 8 days of repeated rounds of biofilm formation using ATS2015 containing Enterococcus faecalis and Pseudomonas aeruginosa, rinsing, fixation with glutaraldehyde, and rinsing. Viable count and scanning electron microscopy and borescope examination were used to compare the impact of dry storage over 26 weeks on the level of culturable bacteria and to compare the Centers for Disease Control and Prevention flush method of channel harvesting with a flush-brush-flush method. RESULTS E faecalis (log10 6.6) and P aeruginosa (log10 8.6) accumulated over 8 days of cyclic biofilm formation and partial glutaraldehyde fixation, but after a final exposure to 2.6% glutaraldehyde the level of culturable bacteria was less than 2 log10. The Centers for Disease Control and Prevention channel harvesting method appeared by borescope to be inferior to a flush-brush-flush sample collection method for detection of viable bacteria. P aeruginosa increased up to 7 log10 after 26 weeks of dry storage, indicating there were viable but nonculturable bacteria present initially that recovered during storage. CONCLUSIONS Viable but nonculturable P aeruginosa within the BBF model are able to recover, and this phenomenon may explain the variability of culture in patient-used endoscopes. Our data also indicated that friction may be a critical part of sample collection from endoscope channels.
Collapse
Affiliation(s)
- Michelle J Alfa
- St Boniface Research Centre, Winnipeg, Manitoba, Canada; Department of Medical Microbiology, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Maira M Ribeiro
- Clinical Hospital of Federal University of Minas Gerais, Belo Horizonte, Brazil
| | | | - Rodrigo Franca
- Department of Dentistry, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Nancy Olson
- St Boniface Research Centre, Winnipeg, Manitoba, Canada
| | - Pat DeGagne
- St Boniface Research Centre, Winnipeg, Manitoba, Canada
| | - Harminder Singh
- Department of Internal Medicine, University of Manitoba, Winnipeg, Manitoba, Canada
| |
Collapse
|
18
|
Affiliation(s)
- John Baillie
- Gastroenterology, Virginia Commonwealth University Health System, Richmond, Virginia, USA
| |
Collapse
|
19
|
Affiliation(s)
- Richard A. Kozarek
- Digestive Disease Institute, Virginia Mason Medical Center, Seattle, Washington, United States
| |
Collapse
|