McMellen CJ, Sinkler MA, Calcei JG, Hobson TE, Karns MR, Voos JE. Management of Bone Loss and Tunnel Widening in Revision ACL Reconstruction. J Bone Joint Surg Am 2023; 105:1458-1471. [PMID: 37506198 DOI: 10.2106/jbjs.22.01321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 07/30/2023]
Abstract
➤ Both mechanical and biological factors can contribute to bone loss and tunnel widening following primary anterior cruciate ligament (ACL) reconstruction.➤ Revision ACL surgery success is dependent on graft position, fixation, and biological incorporation.➤ Both 1-stage and 2-stage revision ACL reconstructions can be successful in correctly indicated patients.➤ Potential future solutions may involve the incorporation of biological agents to enhance revision ACL surgery, including the use of bone marrow aspirate concentrate, platelet-rich plasma, and bone morphogenetic protein-2.
Collapse
Affiliation(s)
- Christopher J McMellen
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, Ohio
| | - Margaret A Sinkler
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, Ohio
| | - Jacob G Calcei
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, Ohio
- University Hospitals Drusinsky Sports Medicine Institute, Cleveland, Ohio
| | - Taylor E Hobson
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, Ohio
- University Hospitals Drusinsky Sports Medicine Institute, Cleveland, Ohio
| | - Michael R Karns
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, Ohio
- University Hospitals Drusinsky Sports Medicine Institute, Cleveland, Ohio
| | - James E Voos
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, Ohio
- University Hospitals Drusinsky Sports Medicine Institute, Cleveland, Ohio
| |
Collapse
|
2
|
Emerzian SR, Wu T, Vaidya R, Tang SY, Abergel RJ, Keaveny TM. Relative Effects of Radiation-Induced Changes in Bone Mass, Structure, and Tissue Material on Vertebral Strength in a Rat Model. J Bone Miner Res 2023; 38:1032-1042. [PMID: 37191221 PMCID: PMC10524463 DOI: 10.1002/jbmr.4828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 04/06/2023] [Accepted: 05/07/2023] [Indexed: 05/17/2023]
Abstract
The observed increased risk of fracture after cancer radiation therapy is presumably due to a radiation-induced reduction in whole-bone strength. However, the mechanisms for impaired strength remain unclear, as the increased fracture risk is not fully explained by changes in bone mass. To provide insight, a small animal model was used to determine how much of this whole-bone weakening effect for the spine is attributable to changes in bone mass, structure, and material properties of the bone tissue and their relative effects. Further, because women have a greater risk of fracture after radiation therapy than men, we investigated if sex had a significant influence on bone's response to irradiation. Fractionated in vivo irradiation (10 × 3 Gy) or sham irradiation (0 Gy) was administered daily to the lumbar spine in twenty-seven 17-week-old Sprague-Dawley rats (n = 6-7/sex/group). Twelve weeks after final treatment, animals were euthanized, and lumbar vertebrae (L4 and L5 ) were isolated. Using a combination of biomechanical testing, micro-CT-based finite element analysis, and statistical regression analysis, we separated out the effect of mass, structural, and tissue material changes on vertebral strength. Compared with the sham group (mean ± SD strength = 420 ± 88 N), the mean strength of the irradiated group was lower by 28% (117 N/420 N, p < 0.0001). Overall, the response of treatment did not differ with sex. By combining results from both general linear regression and finite element analyses, we calculated that mean changes in bone mass, structure, and material properties of the bone tissue accounted for 56% (66 N/117 N), 20% (23 N/117 N), and 24% (28 N/117 N), respectively, of the overall change in strength. As such, these results provide insight into why an elevated clinical fracture risk for patients undergoing radiation therapy is not well explained by changes in bone mass alone. © 2023 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).
Collapse
Affiliation(s)
- Shannon R. Emerzian
- Department of Mechanical Engineering, University of
California, Berkeley, California, USA
| | - Tongge Wu
- Department of Mechanical Engineering, University of
California, Berkeley, California, USA
| | - Rachana Vaidya
- Department of Orthopaedic Surgery, Washington University,
St. Louis, Missouri, USA
| | - Simon Y. Tang
- Department of Orthopaedic Surgery, Washington University,
St. Louis, Missouri, USA
- Department of Biomedical Engineering, Washington
University, St. Louis, Missouri, USA
- Department of Material Science & Mechanical
Engineering, Washington University, St. Louis, Missouri, USA
| | - Rebecca J. Abergel
- Department of Nuclear Engineering, University of
California, Berkeley, California, USA
| | - Tony M. Keaveny
- Department of Mechanical Engineering, University of
California, Berkeley, California, USA
- Department of Bioengineering, University of California,
Berkeley, California, USA
| |
Collapse
|
3
|
Crocker DB, Hoffman I, Carter JL, Akkus O, Rimnac CM. Fatigue crack propagation and fracture toughness of cortical bone are radiation dose-dependent. J Orthop Res 2023; 41:823-833. [PMID: 35949192 PMCID: PMC9911555 DOI: 10.1002/jor.25424] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 07/08/2022] [Accepted: 08/09/2022] [Indexed: 02/04/2023]
Abstract
Cortical bone allograft sterilized with a standard γ-radiation dose of 25-35kGy has demonstrated reduced static and cyclic fracture resistance compared with unirradiated bone. To mitigate radiation damage, we recently observed a dose-dependent response of high-cycle fatigue behavior of human cortical bone from 0 to 25 kGy, with lower doses exhibiting logarithmically longer fatigue lives. The objectives of this study were as follows: (1) to determine whether fracture toughness, work-to-fracture, and fatigue crack propagation resistance of human cortical bone are also radiation dose-dependent, and (2) to determine the associations of radiation dose and a Raman biomarker for collagen disorder with fracture properties. Compact tension specimens were machined from two donor femoral pairs and allocated to four treatment groups: 0 (unirradiated control), 10, 17.5, and 25 kGy. Fracture toughness specimens were monotonically loaded to failure and the critical stress intensity factor (KC ) was determined. Work-to-fracture was calculated from the load versus displacement integral up to fracture. Fatigue crack propagation specimens were cyclically loaded under constant room-temperature irrigation and fatigue crack growth rate (da/dN) and cyclic stress intensity (∆K) were calculated. Fracture toughness, work-to-fracture, and fatigue crack propagation resistance decreased 18%, 33%, and 15-fold from 0 to 25 kGy, respectively (p < 0.05). Radiation dose was more predictive of fracture properties than collagen disorder. These findings support that quasi-static and fatigue fracture properties of cortical bone are radiation dose-dependent within this dose range. The structural alterations arising from irradiation that cause these losses in fracture resistance remain to be elucidated.
Collapse
Affiliation(s)
- Dylan B. Crocker
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH
| | - Isaac Hoffman
- Department of Materials Science and Engineering, Case Western Reserve University, Cleveland, OH
| | - Jennifer L.W. Carter
- Department of Materials Science and Engineering, Case Western Reserve University, Cleveland, OH
| | - Ozan Akkus
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH
- Department of Orthopaedic Surgery, Case Western Reserve University, Cleveland, OH
| | - Clare M. Rimnac
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH
- Department of Orthopaedic Surgery, Case Western Reserve University, Cleveland, OH
| |
Collapse
|
4
|
Kranenburg A, Garcia-Diaz G, Cook JH, Thambuswamy M, James W, Stevens D, Bruggeman A, Chen Y, Capobianco R, Reckling WC, Siegal JD. Revision of Failed Sacroiliac Joint Posterior Interpositional Structural Allograft Stabilization with Lateral Porous Titanium Implants: A Multicenter Case Series. MEDICAL DEVICES (AUCKLAND, N.Z.) 2022; 15:229-239. [PMID: 35899066 PMCID: PMC9309279 DOI: 10.2147/mder.s369808] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Accepted: 07/12/2022] [Indexed: 12/26/2022]
Abstract
Background Distraction arthrodesis (DA) and stabilization of the sacroiliac (SI) joint by placing standalone structural allograft (SA) into the joint from a posterior trajectory has recently been introduced as a surgical procedure for chronic SI joint pain refractory to non-operative care. Methods Retrospective case series of patients with recurrent and/or persistent pain after placement of one or more interpositional/intraarticular standalone SAs between the ilium and sacrum using a posterior procedure to treat SI joint pain/dysfunction. Patients subsequently underwent surgical revision with porous titanium fusion implants using a lateral transfixing procedure. The demographic, clinical, and radiographic features of these cases are described. Results Data were available for 37 patients. The average (SD) age was 57 (13) years, 62% were female, and the average BMI was 31 (5.4). On average, two SA implants were placed per joint; 46% of cases were bilateral. At follow-up, two common themes were identified: lucencies around the implants and suboptimal implant position. None of the cases showed radiographic fusion of the SI joint prior to revision. One patient had an inflammatory reaction to the SA. All patients presented for revision due to either continued (49%) or recurrence (51%) of pain. In one revision case, the SA was forced ventrally, resulting in a sacral fracture, which was treated conservatively without sequelae. Conclusions The popularity of standalone SA for SI joint stabilization/fusion with a posterior procedure is increasing. This case series demonstrates that clinical failures from this procedure may require surgical revision. The proposed fusion strategy (DA) for these products is unproven in the SI joint, and, therefore, properly conducted prospective randomized clinical trials with long-term clinical and radiographic follow-up are important to establish the safety and efficacy of this approach. In the meantime, the placement of lateral titanium implants appears to be an effective revision strategy.
Collapse
|
5
|
Ina J, Vakharia A, Akkus O, Rimnac CM. The High-cycle Fatigue Life of Cortical Bone Allografts Is Radiation Sterilization Dose-dependent: An In Vitro Study. Clin Orthop Relat Res 2022; 480:1208-1219. [PMID: 35175232 PMCID: PMC9263473 DOI: 10.1097/corr.0000000000002146] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Accepted: 01/28/2022] [Indexed: 01/31/2023]
Abstract
BACKGROUND Structural cortical bone allografts are a reasonable treatment option for patients with large cortical bone defects caused by trauma, tumors, or complications of arthroplasty. Although structural cortical bone allografts provide the benefit of an osteoconductive material, they are susceptible to fatigue failure (fracture) and carry a risk of disease transmission. Radiation-sterilization at the recommended dose of 25 kGy decreases the risk of disease transmission. However, previous studies demonstrated that radiation sterilization at this dose can negatively impact the high cycle-fatigue life of cortical bone. Although the effects of higher doses of radiation on cortical bone allografts are well described, the effects of lower doses of radiation on a high-cycle fatigue life of cortical bone are poorly understood. QUESTIONS/PURPOSES (1) Does the cycle-fatigue life of human cortical allograft bone vary with gamma radiation dose levels of 0 (control), 10 kGy, 17.5 kGy, and 25 kGy? (2) What differences in Raman spectral biomarkers are observed following varying doses of gamma radiation exposure? METHODS The high-cycle fatigue behavior of human cortical bone specimens was examined at different radiation sterilization doses under physiologic stress levels (35 MPa) and in a 37° C phosphate-buffered saline bath using a custom-designed rotating-bending fatigue device. Six human femora from three donors were obtained for this study (two male, 63 and 61 years old, respectively, and one female, 48 years old). Test specimens were allocated among four treatment groups (0 kGy [control], 10 kGy, 17.5 kGy, and 25 kGy) based on donor and anatomic location of harvest site (both length and cross-sectional quadrant of femoral diaphysis) to ensure equal variation (n = 13 per group). Specimens underwent high-cycle fatigue testing to failure. The number of cycles to failure was recorded. Raman spectroscopy (a noninvasive vibrational spectroscopy used to qualitatively assess bone quality) was used to detect whether any changes in Raman spectral biomarkers occurred after varying doses of gamma radiation exposure. RESULTS There was a decrease in the log-transformed mean high-cycle fatigue life in specimens irradiated at 25 kGy (5.39 ± 0.32) compared with all other groups (0 kGy: 6.20 ± 0.50; 10k Gy: 6.35 ± 0.79; 17.5 kGy: 6.01 ± 0.53; p = 0.001). Specimens irradiated at 25 kGy were also more likely to exhibit a more brittle fracture surface pattern than specimens with more ductile fracture surface patterns irradiated at 0 kGy, 10 kGy, and 17.5 kGy (p = 0.04). The Raman biomarker for the ratio of the relative amount of disordered collagen to ordered collagen showed a decrease at the 10 kGy radiation level from 1.522 ± 0.025 preirradiation to 1.489 ± 0.024 postirradiation (p = 0.01); no other detectable changes in Raman biomarkers were observed. CONCLUSION The high-cycle fatigue life of cortical bone undergoes a nonlinear, dose-dependent decrease with an increase in gamma radiation sterilization in a clinically relevant dose range (0-25 kGy). Importantly, a notable drop-off in the high-cycle fatigue life of cortical bone appeared to occur between 17.5 kGy and 25 kGy, correlating to a sixfold decrease in mean cycles to failure. We speculate that the decrease in the Raman biomarker for disordered collagen at 10 kGy with no loss in high-cycle fatigue life may be caused by an increased amount of nonenzymatic crosslinking of the collagen backbone relative to collagen chain-scission (whereas the benefits of crosslinking may be outweighed by excess scission of the collagen backbone at higher radiation doses), but future studies will need to ascertain whether this in fact is the case. CLINICAL RELEVANCE Radiation sterilization at the industry standard of 25 kGy has a substantial negative impact on the high-cycle fatigue life of cortical bone. Given these findings, it is possible to provide a meaningful increase in the high-cycle fatigue life and improve the overall functional lifetime of cortical bone allografts by lowering the radiation-sterilization dose below 25 kGy. Future work on radiation-sterilization methods at these clinically relevant doses is warranted to aid in preserving the high cycle fatigue life of cortical bone allografts while maintaining sterility.
Collapse
Affiliation(s)
- Jason Ina
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, OH, USA
| | - Ajit Vakharia
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, OH, USA
| | - Ozan Akkus
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, OH, USA
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Clare M. Rimnac
- Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, OH, USA
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH, USA
| |
Collapse
|
6
|
Walsh WR. CORR Insights®: The High-cycle Fatigue Life of Cortical Bone Allografts Is Radiation Sterilization Dose-dependent: An In Vitro Study. Clin Orthop Relat Res 2022; 480:1220-1221. [PMID: 35302541 PMCID: PMC9263481 DOI: 10.1097/corr.0000000000002182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 02/28/2022] [Indexed: 01/31/2023]
Affiliation(s)
- William R Walsh
- Professor, University of New South Wales Surgical and Orthopaedic Research Laboratories, Prince of Wales Hospital, Sydney Australia
| |
Collapse
|
7
|
Du JY. CORR Insights®: Deep-freezing Temperatures During Irradiation Preserves the Compressive Strength of Human Cortical Bone Allografts: A Cadaver Study. Clin Orthop Relat Res 2022; 480:419-420. [PMID: 34543248 PMCID: PMC8747489 DOI: 10.1097/corr.0000000000001995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Accepted: 09/08/2021] [Indexed: 02/03/2023]
Affiliation(s)
- Jerry Y Du
- Resident, Department of Orthopaedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, OH, USA
| |
Collapse
|
8
|
Yang Harmony TC, Yusof N, Ramalingam S, Baharin R, Syahrom A, Mansor A. Deep-Freezing Temperatures During Irradiation Preserves the Compressive Strength of Human Cortical Bone Allografts: A Cadaver Study. Clin Orthop Relat Res 2022; 480:407-418. [PMID: 34491235 PMCID: PMC8747490 DOI: 10.1097/corr.0000000000001968] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 08/16/2021] [Indexed: 02/03/2023]
Abstract
BACKGROUND Gamma irradiation, which minimizes the risk of infectious disease transmission when human bone allograft is used, has been found to negatively affect its biomechanical properties. However, in those studies, the deep-freezing temperature during irradiation was not necessarily maintained during transportation and sterilization, which may have affected the findings. Prior reports have also suggested that controlled deep freezing may mitigate the detrimental effects of irradiation on the mechanical properties of bone allograft. QUESTION/PURPOSE Does a controlled deep-freezing temperature during irradiation help preserve the compressive mechanical properties of human femoral cortical bone allografts? METHODS Cortical bone cube samples, each measuring 64 mm3, were cut from the mid-diaphyseal midshaft of five fresh-frozen cadaver femurs (four male donors, mean [range] age at procurement 42 years [42 to 43]) and were allocated via block randomization into one of three experimental groups (with equal numbers of samples from each donor allocated into each group). Each experimental group consisted of 20 bone cube samples. Samples irradiated in dry ice were subjected to irradiation doses ranging from 26.7 kGy to 27.1 kGy (mean 26.9 kGy) at a deep-freezing temperature below -40°C (the recommended long-term storage temperature for allografts). Samples irradiated in gel ice underwent irradiation doses ranging from 26.2 kGy and 26.4 kGy (mean 26.3 kGy) in a freezing temperature range between -40°C and 0°C. Acting as controls, samples in a third group were not subjected to gamma irradiation. The mechanical properties (0.2% offset yield stress, ultimate compression stress, toughness, and the Young modulus) of samples from each group were subsequently evaluated via axial compression loading to failure along the long axis of the bone. The investigators were blinded to sample group during compression testing. RESULTS The mean ultimate compression stress (84 ± 27 MPa versus 119 ± 31 MPa, mean difference 35 [95% CI 9 to 60]; p = 0.005) and toughness (3622 ± 1720 kJ/m3 versus 5854 ± 2900 kJ/m3, mean difference 2232 [95% CI 70 to 4394]; p = 0.009) of samples irradiated at a higher temperature range (-40°C to 0°C) were lower than in those irradiated at deep-freezing temperatures (below -40°C). The mean 0.2% offset yield stress (73 ± 28 MPa versus 109 ± 38 MPa, mean difference 36 [95% CI 11 to 60]; p = 0.002) and ultimate compression stress (84 ± 27 MPa versus 128 ± 40 MPa, mean difference 44 [95% CI 17 to 69]; p < 0.001) of samples irradiated at a higher temperature range (-40°C to 0°C) were lower than the nonirradiated control group samples. The mean 0.2% offset yield stress (73 ± 28 MPa versus 101 ± 28 MPa, mean difference 28 [95% CI 3 to 52]; p = 0.02; effect size = 1.0 [95% CI 0.8 to 1.2]) of samples irradiated at higher temperature range (-40°C to 0°C) were no different with the numbers available to those irradiated at deep-freezing temperature. The mean toughness (3622 ± 1720 kJ/m3 versus 6231 ± 3410 kJ/m3, mean difference 2609 [95% CI 447 to 4771]; p = 0.02; effect size = 1.0 [95% CI 0.8 to 1.2]) of samples irradiated at higher temperature range (-40°C to 0°C) were no different with the numbers available to the non-irradiated control group samples. The mean 0.2% offset yield stress, ultimate compression stress, and toughness of samples irradiated in deep-freezing temperatures (below -40°C) were not different with the numbers available to the non-irradiated control group samples. The Young modulus was not different with the numbers available among the three groups. CONCLUSION In this study, maintenance of a deep-freezing temperature below -40°C, using dry ice as a cooling agent, consistently mitigated the adverse effects of irradiation on the monotonic-compression mechanical properties of human cortical bone tissue. Preserving the mechanical properties of a cortical allograft, when irradiated in a deep-freezing temperature, may have resulted from attenuation of the deleterious, indirect effects of gamma radiation on its collagen architecture in a frozen state. Immobilization of water molecules in this state prevents radiolysis and the subsequent generation of free radicals. This hypothesis was supported by an apparent loss of the protective effect when a range of higher freezing temperatures was used during irradiation. CLINICAL RELEVANCE Deep-freezing temperatures below -40°C during gamma irradiation may be a promising approach to better retain the native mechanical properties of cortical bone allografts. A further study of the effect of deep-freezing during gamma radiation sterilization on sterility and other important biomechanical properties of cortical bone (such as, tensile strength, fracture toughness, and fatigue) is needed to confirm these findings.
Collapse
Affiliation(s)
- Tan Chern Yang Harmony
- Ministry of Health Malaysia, Federal Government Administrative Centre, Putrajaya, Malaysia
| | - Norimah Yusof
- Bone Bank, National Orthopaedic Centre of Excellence in Research and Learning, Kuala Lumpur, Malaysia
- Department of Orthopaedic Surgery, University of Malaya, Kuala Lumpur, Malaysia
- Jalan Universiti, Kuala Lumpur, Malaysia
| | - Saravana Ramalingam
- Bone Bank, National Orthopaedic Centre of Excellence in Research and Learning, Kuala Lumpur, Malaysia
- Department of Orthopaedic Surgery, University of Malaya, Kuala Lumpur, Malaysia
- Jalan Universiti, Kuala Lumpur, Malaysia
| | | | - Ardiyansyah Syahrom
- Medical Device Technology Center, Institute of Human Centered Engineering, Skudai Johor, Malaysia
- Faculty of Engineering, Universiti Teknologi Malaysia, Skudai Johor, Malaysia
| | - Azura Mansor
- Bone Bank, National Orthopaedic Centre of Excellence in Research and Learning, Kuala Lumpur, Malaysia
- Department of Orthopaedic Surgery, University of Malaya, Kuala Lumpur, Malaysia
- Jalan Universiti, Kuala Lumpur, Malaysia
| |
Collapse
|
9
|
Lee MH, Jeong H, Koo MA, Seon GM, Hong SH, Park YJ, Park JC. Sterilization of sealed PVDF pouches containing decellularized scaffold by electrical stimulation. Biotechnol J 2021; 16:e2100156. [PMID: 34374222 DOI: 10.1002/biot.202100156] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 07/26/2021] [Accepted: 08/04/2021] [Indexed: 11/11/2022]
Abstract
A terminal sterilization process for tissue engineering products, such as allografts and biomaterials is necessary to ensure complete removal of pathogenic microorganisms such as the bacteria, fungi and viruses. However, it can be difficult to sterilize allografts and artificial tissue models packaged in wet conditions without deformation. In this study, we investigated the sterilization effects of electrical stimulation (ES) and assessed its suitability by evaluating sterility assurance levels in pouches at a constant current. Stability of polyvinylidene fluoride pouches was determined by a sterility test performed after exposure to five microorganisms (Staphylococcus aureus, Bacillus subtilis, Pseudomonas aeruginosa, Escherichia coli, and Candida albicans) for 5 days; the sterility test was also performed with decellularized human dermal tissues inoculated with the five microorganisms. Sterilization using ES inactivated microorganisms both inside and outside of sealed pouches and caused no damage to the packaged tissue. Our results support the development of a novel system that involves ES sterilization for packaging of implantable biomaterials and human derived materials. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Mi Hee Lee
- Cellbiocontrol Laboratory, Department of Medical Engineering, Seoul, Republic of Korea
| | - HaKyeong Jeong
- Cellbiocontrol Laboratory, Department of Medical Engineering, Seoul, Republic of Korea.,Department of Medical Device Engineering and Management, Seoul, Republic of Korea
| | - Min-Ah Koo
- Cellbiocontrol Laboratory, Department of Medical Engineering, Seoul, Republic of Korea.,Graduate School of Medical Science, Brain Korea 21 Project, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Gyeung Mi Seon
- Cellbiocontrol Laboratory, Department of Medical Engineering, Seoul, Republic of Korea.,Graduate School of Medical Science, Brain Korea 21 Project, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Seung Hee Hong
- Cellbiocontrol Laboratory, Department of Medical Engineering, Seoul, Republic of Korea.,Graduate School of Medical Science, Brain Korea 21 Project, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Ye Jin Park
- Cellbiocontrol Laboratory, Department of Medical Engineering, Seoul, Republic of Korea.,Department of Medical Device Engineering and Management, Seoul, Republic of Korea
| | - Jong-Chul Park
- Cellbiocontrol Laboratory, Department of Medical Engineering, Seoul, Republic of Korea.,Department of Medical Device Engineering and Management, Seoul, Republic of Korea.,Graduate School of Medical Science, Brain Korea 21 Project, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| |
Collapse
|
10
|
Amelia F, Abbas B, Darwis D, Estuningsih S, Noviana D. Effects of bone types, particle sizes, and gamma irradiation doses in feline demineralized freeze-dried bone allograft. Vet World 2020; 13:1536-1543. [PMID: 33061224 PMCID: PMC7522947 DOI: 10.14202/vetworld.2020.1536-1543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Accepted: 06/09/2020] [Indexed: 11/16/2022] Open
Abstract
Background and Aim: Fracture cases significantly increase recently, demanding high quality of bone graft materials. This research aimed to evaluate the effects of bone types, particle sizes, and gamma irradiation doses on morphological performance and cell viability of feline demineralized freeze-dried bone allograft (DFDBA) through an in vitro study. Materials and Methods: Feline DFDBA derived from feline cortical and cancellous long bones was processed into four different sizes: Group A (larger than 1000 µm), B (841-1000 µm), C (420-840 µm), and D (250-419 µm) for each type of bones. The materials were then irradiated with two doses of gamma rays, 15 and 25 kGy, resulting in 16 variants of feline DFDBA. The surfaces of each material were then observed with the scanning electron microscope (SEM). The in vitro evaluation of feline DFDBA was then performed using 3-(4,5-dimethythiazol-2)-2,5-diphenyltetrazolium bromide (MTT) assay with calf pulmonary artery endothelial cells. Results: The MTT assay results showed that the lowest inhibition rate (14.67±9.17 %) achieved by feline DFDBA in Group A derived from cortical bones irradiated with 15 kGy. Group D generally showed high inhibition rate in both cancellous and cortical bones, irradiated with either 15 or 25 kGy. The SEM results showed that cancellous and cortical bones have numerous macropores and micropores structure in 170× and 3000×, respectively. Conclusion: The material derived from cortical bones in Group A (larger than 1000 µm in particle size) irradiated with 15 kGy is the best candidate for further development due to its abundance of micropores structure and ability in preserving the living cells.
Collapse
Affiliation(s)
- Frizky Amelia
- Program Study of Animal Biomedical Science, Graduate School of IPB University, Bogor, Jawa Barat 16680, Indonesia.,Diagnostic Imaging Center, Veterinary Teaching Hospital, Faculty of Veterinary Medicine IPB University, Bogor, Jawa Barat 16680, Indonesia
| | - Basril Abbas
- Centre for Isotopes and Radiation Application, National Nuclear Energy Agency (BATAN), Jakarta Selatan, DKI Jakarta 12440, Indonesia
| | - Darmawan Darwis
- Centre for Isotopes and Radiation Application, National Nuclear Energy Agency (BATAN), Jakarta Selatan, DKI Jakarta 12440, Indonesia
| | - Sri Estuningsih
- Department of Clinic Reproduction and Pathology, Faculty of Veterinary Medicine IPB University, Bogor, Jawa Barat 16680, Indonesia
| | - Deni Noviana
- Diagnostic Imaging Center, Veterinary Teaching Hospital, Faculty of Veterinary Medicine IPB University, Bogor, Jawa Barat 16680, Indonesia.,Department of Clinic Reproduction and Pathology, Faculty of Veterinary Medicine IPB University, Bogor, Jawa Barat 16680, Indonesia
| |
Collapse
|
11
|
Mandair GS, Oest ME, Mann KA, Morris MD, Damron TA, Kohn DH. Radiation-induced changes to bone composition extend beyond periosteal bone. Bone Rep 2020; 12:100262. [PMID: 32258252 PMCID: PMC7125315 DOI: 10.1016/j.bonr.2020.100262] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2019] [Revised: 03/25/2020] [Accepted: 03/26/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Cancer patients receiving radiotherapy for soft tissue sarcomas are often at risk of post-irradiation (post-RTx) bone fragility fractures, but our understanding of factors controlling radiation-induced bone injury is limited. Previous studies have evaluated post-RTx changes to cortical bone composition in the periosteum of irradiated tibiae, but have not evaluated effects of irradiation in deeper tissues, such as endosteal or mid-cortical bone, and whether there are differential spatial effects of irradiation. In this study, we hypothesize that post-RTx changes to cortical bone composition are greater in endosteal compared to mid-cortical or periosteal bone. METHODS A pre-clinical mouse model of limited field hindlimb irradiation was used to evaluate spatial and temporal post-RTx changes to the metaphyseal cortex of irradiated tibiae. Irradiation was delivered unilaterally to the hindlimbs of 12-wk old female BALB/cJ mice as 4 consecutive daily doses of 5 Gy each. RTx and non-RTx tibiae were obtained at 0, 2, 4, 8, and 12 wks post-RTx (n = 9 mice/group/time). Raman spectroscopy was used to evaluate spatial and temporal post-RTx changes to cortical bone composition in age-matched RTx and non-RTx groups. RESULTS Significant early spatial differences in mineral/matrix and collagen crosslink ratios were found between endosteal and periosteal or mid-cortical bone at 2-wks post-RTx. Although spatial differences were transient, mineral/matrix ratios significantly decreased and collagen crosslink ratios significantly increased with post-RTx time throughout the entire tibial metaphyseal cortex. CONCLUSIONS Irradiation negatively impacts the composition of cortical bone in a spatially-dependent manner starting as early as 2-wks post-RTx. Long-term progressive post-RTx changes across all cortical bone sites may eventually contribute to the increased risk of post-RTx bone fragility fractures.
Collapse
Affiliation(s)
| | - Megan E. Oest
- Department of Orthopedic Surgery, Upstate Medical University, Syracuse, NY, USA
| | - Kenneth A. Mann
- Department of Orthopedic Surgery, Upstate Medical University, Syracuse, NY, USA
| | | | - Timothy A. Damron
- Department of Orthopedic Surgery, Upstate Medical University, Syracuse, NY, USA
| | - David H. Kohn
- School of Dentistry, University of Michigan, Ann Arbor, MI, USA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, USA
| |
Collapse
|
12
|
Loundagin LL, Haider IT, Cooper DM, Edwards WB. Association between intracortical microarchitecture and the compressive fatigue life of human bone: A pilot study. Bone Rep 2020; 12:100254. [PMID: 32258250 PMCID: PMC7110329 DOI: 10.1016/j.bonr.2020.100254] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Revised: 02/26/2020] [Accepted: 03/02/2020] [Indexed: 11/18/2022] Open
Abstract
Many mechanical properties of cortical bone are largely governed by the underlying microarchitecture; however, the influence of microarchitecture on the fatigue life of bone is poorly understood. Furthermore, imaging-based studies investigating intracortical microarchitecture may expose bone samples to large doses of radiation that may compromise fatigue resistance. The purpose of this pilot study was to 1) investigate the relationship between intracortical microarchitecture and the fatigue life of human bone in compression and 2) examine the effects of synchrotron irradiation on fatigue life measurements. Cortical samples were prepared from the femoral and tibial shafts of three cadaveric donors. A subset of samples was imaged using synchrotron X-ray microCT to quantify microarchitecture, including porosity, canal diameter, lacunar density, lacunar volume, and lacunar orientation. A second group of control samples was not imaged and used only for mechanical testing. Fatigue life was quantified by cyclically loading both groups in zero-compression until failure. Increased porosity and larger canal diameter were both logarithmically related to a shorter fatigue life, whereas lacunar density demonstrated a positive linear relationship with fatigue life (r2 = 45–73%, depending on measure). Irradiation from microCT scanning reduced fatigue life measurements by 91%, but relationships with microarchitecture measurements remained. Additional research is needed to support the findings of this pilot study and fully establish the relationship between intracortical microarchitecture and the compressive fatigue life of bone. Increased porosity and larger canal diameters were associated with a shorter compressive fatigue life. A higher lacunar density was related to a longer compressive fatigue life. Irradiation from synchrotron X-ray microCT scanning reduced fatigue life by 91%. The influence of microarchitecture on fatigue life exhibited similar trends for both irradiated and non-irradiated bone.
Collapse
Affiliation(s)
- Lindsay L. Loundagin
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, 2500 University Drive NW, Calgary, AB T2N 1N4, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, 3280 Hospital Dr NW, Calgary, AB T2N 4Z6, Canada
- Corresponding author at: Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, 2500 University Drive NW, Calgary, AB T2N 1N4, Canada.
| | - Ifaz T. Haider
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, 2500 University Drive NW, Calgary, AB T2N 1N4, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, 3280 Hospital Dr NW, Calgary, AB T2N 4Z6, Canada
| | - David M.L. Cooper
- Department of Anatomy, Physiology and Pharmacology, University of Saskatchewan, 105 Administration Place, Saskatoon, SK S7N 5A2, Canada
| | - W. Brent Edwards
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, 2500 University Drive NW, Calgary, AB T2N 1N4, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, 3280 Hospital Dr NW, Calgary, AB T2N 4Z6, Canada
| |
Collapse
|
13
|
Pendleton MM, Emerzian SR, Liu J, Tang SY, O'Connell GD, Alwood JS, Keaveny TM. Effects of ex vivo ionizing radiation on collagen structure and whole-bone mechanical properties of mouse vertebrae. Bone 2019; 128:115043. [PMID: 31445224 PMCID: PMC6813909 DOI: 10.1016/j.bone.2019.115043] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 08/14/2019] [Accepted: 08/21/2019] [Indexed: 12/26/2022]
Abstract
Bone can become brittle when exposed to ionizing radiation across a wide range of clinically relevant doses that span from radiotherapy (accumulative 50 Gy) to sterilization (~35,000 Gy). While irradiation-induced embrittlement has been attributed to changes in the collagen molecular structure, the relative role of collagen fragmentation versus non-enzymatic collagen crosslinking remains unclear. To better understand the effects of radiation on the bone material without cellular activity, we conducted an ex vivo x-ray radiation experiment on excised mouse lumbar vertebrae. Spinal tissue from twenty-week old, female, C57BL/6J mice were randomly assigned to a single x-ray radiation dose of either 0 (control), 50, 1000, 17,000, or 35,000 Gy. Measurements were made for collagen fragmentation, non-enzymatic collagen crosslinking, and both monotonic and cyclic-loading compressive mechanical properties. We found that the group differences for mechanical properties were more consistent with those for collagen fragmentation than for non-enzymatic collagen crosslinking. Monotonic strength at 17,000 and 35,000 Gy was lower than that of the control by 50% and 73% respectively, (p < 0.001) but at 50 and 1000 Gy was not different than the control. Consistent with those trends, collagen fragmentation only occurred at 17,000 and 35,000 Gy. By contrast, non-enzymatic collagen crosslinking was greater than control for all radiation doses (p < 0.001). All results were consistent both for monotonic and cyclic loading conditions. We conclude that the reductions in bone compressive monotonic strength and fatigue life due to ex vivo ionizing radiation are more likely caused by fragmentation of the collagen backbone than any increases in non-enzymatic collagen crosslinks.
Collapse
Affiliation(s)
- Megan M Pendleton
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA
| | - Shannon R Emerzian
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA
| | - Jennifer Liu
- Department of Orthopaedic Surgery, Washington University, St. Louis, MO, USA
| | - Simon Y Tang
- Department of Orthopaedic Surgery, Washington University, St. Louis, MO, USA; Department of Biomedical Engineering, Washington University, St. Louis, MO, USA; Department of Material Science & Mechanical Engineering, Washington University, St. Louis, MO, USA
| | - Grace D O'Connell
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA; Department of Orthopaedic Surgery, University of California, San Francisco, CA, USA
| | - Joshua S Alwood
- Space Biosciences Division, NASA Ames Research Center, Moffett Field, CA, USA
| | - Tony M Keaveny
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA; Department of Bioengineering, University of California, Berkeley, CA, USA.
| |
Collapse
|
14
|
Kim DH, Bae KC, Kim DW, Choi BC. Two-stage revision anterior cruciate ligament reconstruction. Knee Surg Relat Res 2019; 31:10. [PMID: 32660548 PMCID: PMC7219575 DOI: 10.1186/s43019-019-0010-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Accepted: 08/22/2019] [Indexed: 12/13/2022] Open
Abstract
With the rising number of anterior cruciate ligament (ACL) reconstructions, revision ACL reconstructions are becoming increasingly common. A revision procedure may be performed to improved knee function, correct instability, and facilitate a return to normal activities. When performing a revision reconstruction, the surgeon decides between a single-stage or a two-stage revision. Two-stage revisions are rarely performed, but are particularly useful when addressing substantial tunnel-widening, active infection, and concomitant knee pathology (e.g., malalignment, other ligamentous injuries, meniscal or chondral lesions). Among these potential scenarios requiring a two-stage revision, tunnel-widening is the most common cause; the first stage involves graft removal, tunnel curettage, and bone grafting, followed by revision ACL reconstruction in the second stage. The purpose of this article is to review the preoperative planning, surgical considerations, rehabilitation, and outcomes of two-stage revision ACL reconstructions and summarize the recent literature outlining treatment results.
Collapse
Affiliation(s)
- Du-Han Kim
- Department of Orthopaedic Surgery, Dongsan Medical Center, School of Medicine, Keimyung University, 1035 Dalgubul-ro, Dalseo-gu, Daegu, 42601, South Korea
| | - Ki-Cheor Bae
- Department of Orthopaedic Surgery, Dongsan Medical Center, School of Medicine, Keimyung University, 1035 Dalgubul-ro, Dalseo-gu, Daegu, 42601, South Korea.
| | - Dong-Wan Kim
- Department of Orthopaedic Surgery, Dongsan Medical Center, School of Medicine, Keimyung University, 1035 Dalgubul-ro, Dalseo-gu, Daegu, 42601, South Korea
| | - Byung-Chan Choi
- Department of Orthopaedic Surgery, Dongsan Medical Center, School of Medicine, Keimyung University, 1035 Dalgubul-ro, Dalseo-gu, Daegu, 42601, South Korea
| |
Collapse
|
15
|
Du JY, Flanagan CD, Bensusan JS, Knusel KD, Akkus O, Rimnac CM. Raman Biomarkers Are Associated with Cyclic Fatigue Life of Human Allograft Cortical Bone. J Bone Joint Surg Am 2019; 101:e85. [PMID: 31483404 DOI: 10.2106/jbjs.18.00832] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Structural bone allografts are an established treatment method for long-bone structural defects resulting from such conditions as traumatic injury and sarcoma. The functional lifetime of structural allografts depends on resistance to cyclic loading (cyclic fatigue life), which can lead to fracture at stress levels well below the yield strength. Raman spectroscopy biomarkers can be used to non-destructively assess the 3 primary components of bone (collagen, mineral, and water), and may aid in optimizing allograft selection to decrease fatigue fracture risk. We studied the association of Raman biomarkers with the cyclic fatigue life of human allograft cortical bone. METHODS Twenty-one cortical bone specimens were machined from the femoral diaphyses of 4 human donors (a 63-year old man, a 61-year-old man, a 51-year-old woman, and a 48-year-old woman) obtained from the Musculoskeletal Transplant Foundation. Six Raman biomarkers were analyzed: collagen disorganization, mineral maturation, matrix mineralization, and 3 water compartments. The specimens underwent cyclic fatigue testing under fully reversed conditions (35 and 45 MPa), during which they were tested to fracture or to 30 million cycles ("runout"), simulating 15 years of moderate activity. A tobit censored linear regression model for cyclic fatigue life was created. RESULTS The multivariate model explained 60% of the variance in the cyclic fatigue life (R = 0.604, p < 0.001). Increases in Raman biomarkers for disordered collagen (coefficient: -2.74×10, p < 0.001) and for loosely collagen-bound water compartments (coefficient: -2.11×10, p < 0.001) were associated with a decreased cyclic fatigue life. Increases in Raman biomarkers for mineral maturation (coefficient: 3.50×10, p < 0.001), matrix mineralization (coefficient: 2.32×10, p < 0.001), tightly collagen-bound water (coefficient: 1.19×10, p < 0.001), and mineral-bound water (coefficient: 3.27×10, p < 0.001) were associated with an increased cyclic fatigue life. Collagen disorder accounted for 44% of the variance in the cyclic fatigue life, mineral maturation accounted for 6%, and all bound water compartments accounted for 3%. CONCLUSIONS Increasing baseline collagen disorder was associated with a decreased cyclic fatigue life and had the strongest correlation with the cyclic fatigue life of human cortical donor bone. This model should be prospectively validated. CLINICAL RELEVANCE Raman analysis is a promising tool for the non-destructive evaluation of structural bone allograft quality for load-bearing applications.
Collapse
Affiliation(s)
- Jerry Y Du
- Department of Orthopedic Surgery, University Hospitals Cleveland Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio
| | - Christopher D Flanagan
- Department of Orthopedic Surgery, University Hospitals Cleveland Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio
| | - Jay S Bensusan
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, Ohio
| | - Konrad D Knusel
- Department of Orthopedic Surgery, University Hospitals Cleveland Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio
| | - Ozan Akkus
- Department of Orthopedic Surgery, University Hospitals Cleveland Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio.,Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, Ohio
| | - Clare M Rimnac
- Department of Orthopedic Surgery, University Hospitals Cleveland Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio.,Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, Ohio
| |
Collapse
|
16
|
Attia T, Grynpas M, Willett T. Ribose pre-treatment can protect the fatigue life of γ-irradiation sterilized bone. Cell Tissue Bank 2019; 20:287-295. [PMID: 31020508 DOI: 10.1007/s10561-019-09767-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Accepted: 04/16/2019] [Indexed: 11/27/2022]
Abstract
Structural bone allografts are often sterilized with γ-irradiation to decrease infection risk, which unfortunately degrades the bone collagen connectivity, making the bone weak and brittle. In previous studies, we successfully protected the quasi-static mechanical properties of human cortical bone by pre-treating with ribose, prior to irradiation. This study focused on the quasi-static and fatigue tensile properties of ribose treated irradiated sterilized bone allografts. Seventy-five samples were cut from the mid-shaft diaphysis of human femurs into standardized dog-bone shape geometries for quasi-static and fatigue tensile testing. Specimens were prepared in sets of three adjacent specimens. Each set was made of a normal (N), irradiated (I) and ribose pre-treated + irradiation (R) group. The R group was incubated in a 1.2 M ribose solution before γ-irradiation. The quasi-static tensile and decalcified tests were conducted to failure under displacement control. The fatigue samples were tested under cyclic loading (10 Hz, peak stress of 45MP, minimum-to-maximum stress ratio of 0.1) until failure or reaching 10 million cycles. Ribose pre-treatment significantly improved significantly the mechanical properties of irradiation sterilized human bone in the quasi-static tensile and decalcified tests. The fatigue life of the irradiated group was impaired by 99% in comparison to the normal control. Surprisingly, the R-group has significantly superior properties over the I-group and N-group (p < 0.01, p < 0.05) (> 100%). This study shows that incubating human cortical bone in a ribose solution prior to irradiation can indeed improve the fatigue life of irradiation-sterilized cortical bone allografts.
Collapse
Affiliation(s)
- Tarik Attia
- Musculoskeletal Research Laboratory, Mount Sinai Hospital - Lunenfeld Tanenbaum Research Institute, Toronto, ON, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON, Canada
| | - Marc Grynpas
- Musculoskeletal Research Laboratory, Mount Sinai Hospital - Lunenfeld Tanenbaum Research Institute, Toronto, ON, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON, Canada
| | - Thomas Willett
- Composite Biomaterial Systems Laboratory, Department of Systems Design Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
17
|
Rahman N, Khan R, Badshah S. Effect of x-rays and gamma radiations on the bone mechanical properties: literature review. Cell Tissue Bank 2018; 19:457-472. [PMID: 30426337 DOI: 10.1007/s10561-018-9736-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Accepted: 10/30/2018] [Indexed: 12/21/2022]
Abstract
The bone auto grafting, isografting, allografting and xenografting are used for defective bone replacement or treatment in almost all living species. The X-ray and Gamma (electromagnetic radiation) sterilization performed on the donor bone graft to prevent toxicity or migration of virus/bacterial infections from donors to reciver. Conversely, X-ray and Gamma radiation deteriorates the bone mechanical properties and bone become more susceptible to fracture. Fracture toughness as well as other mechanical properties of bone change with these radiations. In this literature review the effect of the X-rays and Gamma radiation on bone mechanical properties are discussed. All relevant literature was reviewed. After reviewing the literature only the research relating to the effect of X-rays and Gamma radiations on bone mechanical properties are included. Literature studies showed significant effect of the X-rays and Gamma radiations on the mechanical properties of the bones. In some studies the differences exists on the doses of radiations which were discussed in this study. The high energetic electromagnetic radiation (X-rays and Gamma radiations) changed/modify the collagen network of the bone, which reduced the mechanical properties of bone; however these changes depend on the radiation dose.
Collapse
Affiliation(s)
- Noor Rahman
- Department of Mechanical Engineering, Faculty of Engineering and Technology, International Islamic University, Islamabad, H-10, Pakistan.
| | - Rafiullah Khan
- Department of Mechanical Engineering, Faculty of Engineering and Technology, International Islamic University, Islamabad, H-10, Pakistan
| | - Saeed Badshah
- Department of Mechanical Engineering, Faculty of Engineering and Technology, International Islamic University, Islamabad, H-10, Pakistan
| |
Collapse
|
18
|
Smith RA, Chua R, Carnachan SM, Tan CL, Sims IM, Hinkley SF, Nurcombe V, Cool SM. Retention of the Structure and Function of Heparan Sulfate Biomaterials After Gamma Irradiation. Tissue Eng Part A 2018; 24:729-739. [DOI: 10.1089/ten.tea.2017.0263] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Raymond A.A. Smith
- Glycotherapeutics Group, Institute of Medical Biology, Agency for Science, Technology and Research, Singapore
| | - R.J.E. Chua
- Glycotherapeutics Group, Institute of Medical Biology, Agency for Science, Technology and Research, Singapore
| | - Susan M. Carnachan
- The Ferrier Research Institute, Victoria University of Wellington, Lower Hutt, New Zealand
| | - Clarissa L.L. Tan
- Glycotherapeutics Group, Institute of Medical Biology, Agency for Science, Technology and Research, Singapore
| | - Ian M. Sims
- The Ferrier Research Institute, Victoria University of Wellington, Lower Hutt, New Zealand
| | - Simon F.R. Hinkley
- The Ferrier Research Institute, Victoria University of Wellington, Lower Hutt, New Zealand
| | - Victor Nurcombe
- Glycotherapeutics Group, Institute of Medical Biology, Agency for Science, Technology and Research, Singapore
- Lee Kong Chian School of Medicine, Nanyang Technological University-Imperial College London, Singapore
| | - Simon M. Cool
- Glycotherapeutics Group, Institute of Medical Biology, Agency for Science, Technology and Research, Singapore
- Department of Orthopaedic Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| |
Collapse
|
19
|
He B, Zhao J, Ou Y, Jiang D. Biofunctionalized peptide nanofiber-based composite scaffolds for bone regeneration. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2018; 90:728-738. [PMID: 29853144 DOI: 10.1016/j.msec.2018.04.063] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Revised: 04/15/2018] [Accepted: 04/19/2018] [Indexed: 12/21/2022]
Abstract
Bone tissue had moderate self-healing capabilities, but biomaterial scaffolds were required for the repair of some defects such as large bone defects. Peptide nanofiber scaffolds demonstrated important potential in regenerative medicine. Functional modification and controlled release of signal molecules were two significant approaches to increase the bioactivity of biofunctionalized peptide nanofiber scaffolds, but peptide scaffolds were limited by insufficient mechanical strength. Thus, it was necessary to combine peptide scaffolds with other materials including polymers, hydroxyapatite, demineralized bone matrix (DBM) and metal materials based on the requirement of different bone defects. As the development of peptide-based composite scaffolds continued to evolve, ultimate translation to the clinical environment may allow for improved therapeutic outcomes for bone repair.
Collapse
Affiliation(s)
- Bin He
- Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
| | - Jinqiu Zhao
- Department of Infectious Diseases, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
| | - Yunsheng Ou
- Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.
| | - Dianming Jiang
- Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
| |
Collapse
|
20
|
Van de Pol GJ, Bonar F, Salmon LJ, Roe JP, Pinczewski LA. Supercritical Carbon Dioxide-Sterilized Bone Allograft in the Treatment of Tunnel Defects in 2-Stage Revision Anterior Cruciate Ligament Reconstruction: A Histologic Evaluation. Arthroscopy 2018; 34:706-713. [PMID: 29273252 DOI: 10.1016/j.arthro.2017.08.311] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2017] [Revised: 08/30/2017] [Accepted: 08/30/2017] [Indexed: 02/02/2023]
Abstract
PURPOSE To examine the histologic properties of supercritical carbon dioxide (sCO2)-sterilized bone allograft for tunnel grafting and determine in vivo graft quality, as well as graft incorporation and remodeling, in 2-stage revision anterior cruciate ligament (ACL) surgery. METHODS Histologic evaluation was performed in 12 subjects undergoing 2-stage revision ACL reconstruction. In the first stage, the femoral and tibial tunnels were debrided, tunnel dimensions were measured, and tunnels were grafted with sCO2-sterilized bone allograft. In the second stage, revision ACL reconstruction was performed and bone biopsy specimens were taken from the tibia. Tissue, bone, and graft volumes were measured, and histomorphometric analysis was performed. RESULTS The mean time between the 2 stages was 8.8 months (range, 5.6-21.3 months). In the second stage, bone graft material was easily identified by its necrotic appearance comprising mature lamellar bone devoid of osteocyte nuclei within osteocyte lacunae. In all tissue samples, host-bone apposition of predominantly mature lamellar bone was noted on the surface of graft fragments in keeping with "creeping substitution." In several regions in 3 cases, osteoblastic and osteoclastic activity was evident in keeping with ongoing creeping substitution and remodeling. The mean bone volume over tissue volume was 68% (range, 33%-92%), and the mean graft volume over bone volume was 41% (range, 19%-70%). The mean graft volume (8 cases) harvested at less than 7 months (44%; 95% confidence interval, 31.4%-56.8%) was not significantly different than the mean graft volume (4 cases) harvested at greater than 10 months (34%; 95% confidence interval, 14.3%-54.2%; P = .214). CONCLUSIONS The sCO2-sterilized bone allograft showed graft incorporation and remodeling through creeping substitution. CLINICAL RELEVANCE The initial bone apposition and graft fragment bridging appear to provide a strong environment for ACL graft fixation resulting in technically successful 2-stage revision ACL reconstruction.
Collapse
Affiliation(s)
- Gerrit J Van de Pol
- North Sydney Orthopaedic and Sports Medicine Centre, Wollstonecraft, Australia.
| | - Fiona Bonar
- Notre Dame University Medical School, Chippendale, Australia
| | - Lucy J Salmon
- North Sydney Orthopaedic and Sports Medicine Centre, Wollstonecraft, Australia
| | - Justin P Roe
- North Sydney Orthopaedic and Sports Medicine Centre, Wollstonecraft, Australia
| | - Leo A Pinczewski
- North Sydney Orthopaedic and Sports Medicine Centre, Wollstonecraft, Australia
| |
Collapse
|
21
|
Cai X, Peralta L, Giron A, Helfen L, Olivier C, Peyrin F, Laugier P, Grimal Q. Cortical bone elasticity measured by resonant ultrasound spectroscopy is not altered by defatting and synchrotron X-ray imaging. J Mech Behav Biomed Mater 2017; 72:241-245. [DOI: 10.1016/j.jmbbm.2017.05.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Revised: 03/25/2017] [Accepted: 05/05/2017] [Indexed: 11/15/2022]
|
22
|
Flanagan CD, Unal M, Akkus O, Rimnac CM. Raman spectral markers of collagen denaturation and hydration in human cortical bone tissue are affected by radiation sterilization and high cycle fatigue damage. J Mech Behav Biomed Mater 2017; 75:314-321. [PMID: 28772165 DOI: 10.1016/j.jmbbm.2017.07.016] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Revised: 06/28/2017] [Accepted: 07/11/2017] [Indexed: 12/27/2022]
Abstract
BACKGROUND Thermal denaturation and monotonic mechanical damage alter the organic and water-related compartments of cortical bone. These changes can be detected using Raman spectroscopy. However, less is known regarding Raman sensitivity to detect the effects of cyclic fatigue damage and allograft sterilization doses of gamma radiation. OBJECTIVE To determine if Raman spectroscopic biomarkers of collagen denaturation and hydration are sensitive to the effects of (a) high cycle fatigue damage and (b) 25kGy irradiation. METHODS Unirradiated and gamma-radiation sterilized human cortical bone specimens previously tested in vitro under high-cycle (> 100,000 cycles) fatigue conditions at 15MPa, 25MPa, 35MPa, 45MPa, and 55MPa cyclic stress levels were studied. Cortical bone Raman spectral profiles from wavenumber ranges of 800-1750cm-1 and 2700-3800cm-1 were obtained and compared from: a) non-fatigue vs fatigue fracture sites and b) radiated vs. unirradiated states. Raman biomarker ratios 1670/1640 and 3220/2949, which reflect collagen denaturation and organic matrix (mainly collagen)-bound water, respectively, were assessed. One- and two-way ANOVA analyses were utilized to identify differences between groups along with interaction effects between cyclic fatigue and radiation-induced damage. RESULTS Cyclic fatigue damage resulted in increases in collagen denaturation (1670/1640: 1.517 ± 0.043 vs 1.579 ± 0.021, p < 0.001) and organic matrix-bound water (3220/2949: 0.109 ± 0.012 vs 0.131 ± 0.008, p < 0.001). Organic matrix-bound water increased secondary to 25kGy irradiation (3220/2949: 0.105 ± 0.010 vs 0.1161 ± 0.009, p = 0.003). Organic matrix-bound water was correlated positively with collagen denaturation (r = 0.514, p < 0.001). CONCLUSIONS Raman spectroscopy can detect the effects of cyclic fatigue damage and 25kGy irradiation via increases in organic matrix (mainly collagen)-bound water. A Raman measure of collagen denaturation was sensitive to cyclic fatigue damage but not 25kGy irradiation. Collagen denaturation was correlated with organic matrix-bound water, suggesting that denaturation of collagen to gelatinous form may expose more binding sites to water by unwinding the triple alpha chains. This research may eventually be useful to help identify allograft quality and more appropriately match donors to recipients.
Collapse
Affiliation(s)
- Christopher D Flanagan
- Department of Orthopaedics, Case Western Reserve University School of Medicine, 11100 Euclid Avenue, Cleveland, OH 44106, USA.
| | - Mustafa Unal
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, USA
| | - Ozan Akkus
- Department of Orthopaedics, Case Western Reserve University School of Medicine, 11100 Euclid Avenue, Cleveland, OH 44106, USA; Department of Mechanical and Aerospace Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, USA
| | - Clare M Rimnac
- Department of Orthopaedics, Case Western Reserve University School of Medicine, 11100 Euclid Avenue, Cleveland, OH 44106, USA; Department of Mechanical and Aerospace Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, USA
| |
Collapse
|
23
|
Draenert FG, Kämmerer PW, Berthold M, Neff A. Complications with allogeneic, cancellous bone blocks in vertical alveolar ridge augmentation: prospective clinical case study and review of the literature. Oral Surg Oral Med Oral Pathol Oral Radiol 2016; 122:e31-43. [DOI: 10.1016/j.oooo.2016.02.018] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Accepted: 02/25/2016] [Indexed: 12/31/2022]
|