1
|
Saadatmand P, Mahdavi SR, Nikoofar A, Jazaeri SZ, Ramandi FL, Esmaili G, Vejdani S. A dosiomics model for prediction of radiation-induced acute skin toxicity in breast cancer patients: machine learning-based study for a closed bore linac. Eur J Med Res 2024; 29:282. [PMID: 38735974 PMCID: PMC11089719 DOI: 10.1186/s40001-024-01855-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Accepted: 04/23/2024] [Indexed: 05/14/2024] Open
Abstract
BACKGROUND Radiation induced acute skin toxicity (AST) is considered as a common side effect of breast radiation therapy. The goal of this study was to design dosiomics-based machine learning (ML) models for prediction of AST, to enable creating optimized treatment plans for high-risk individuals. METHODS Dosiomics features extracted using Pyradiomics tool (v3.0.1), along with treatment plan-derived dose volume histograms (DVHs), and patient-specific treatment-related (PTR) data of breast cancer patients were used for modeling. Clinical scoring was done using the Common Terminology Criteria for Adverse Events (CTCAE) V4.0 criteria for skin-specific symptoms. The 52 breast cancer patients were grouped into AST 2 + (CTCAE ≥ 2) and AST 2 - (CTCAE < 2) toxicity grades to facilitate AST modeling. They were randomly divided into training (70%) and testing (30%) cohorts. Multiple prediction models were assessed through multivariate analysis, incorporating different combinations of feature groups (dosiomics, DVH, and PTR) individually and collectively. In total, seven unique combinations, along with seven classification algorithms, were considered after feature selection. The performance of each model was evaluated on the test group using the area under the receiver operating characteristic curve (AUC) and f1-score. Accuracy, precision, and recall of each model were also studied. Statistical analysis involved features differences between AST 2 - and AST 2 + groups and cutoff value calculations. RESULTS Results showed that 44% of the patients developed AST 2 + after Tomotherapy. The dosiomics (DOS) model, developed using dosiomics features, exhibited a noteworthy improvement in AUC (up to 0.78), when spatial information is preserved in the dose distribution, compared to DVH features (up to 0.71). Furthermore, a baseline ML model created using only PTR features for comparison with DOS models showed the significance of dosiomics in early AST prediction. By employing the Extra Tree (ET) classifiers, the DOS + DVH + PTR model achieved a statistically significant improved performance in terms of AUC (0.83; 95% CI 0.71-0.90), accuracy (0.70), precision (0.74) and sensitivity (0.72) compared to other models. CONCLUSIONS This study confirmed the benefit of dosiomics-based ML in the prediction of AST. However, the combination of dosiomics, DVH, and PTR yields significant improvement in AST prediction. The results of this study provide the opportunity for timely interventions to prevent the occurrence of radiation induced AST.
Collapse
Affiliation(s)
- Pegah Saadatmand
- Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Seied Rabi Mahdavi
- Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.
- Radiation Biology Research Center, Iran University of Medical Sciences, Tehran, Iran.
| | - Alireza Nikoofar
- Department of Radiation Oncology, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Seyede Zohreh Jazaeri
- Department of Neuroscience, Faculty of Advanced Technologies in Medicine, Iran University of Medical Sciences, Tehran, Iran
- Division of NeuroscienceCellular and Molecular Research Center, Iran University of Medical Sciences, Tehran, Iran
| | | | | | - Soheil Vejdani
- Department of Radiation Oncology, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
- Department of Radiation Oncology, Firoozgar Hospital, Iran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
2
|
Gueiderikh A, Kirova Y. Radio-induced lung injury after breast helicoidal tomotherapy: long term safety. Acta Oncol 2023; 62:942-943. [PMID: 37527196 DOI: 10.1080/0284186x.2023.2238557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Accepted: 07/06/2023] [Indexed: 08/03/2023]
Affiliation(s)
- A Gueiderikh
- Department of Radiation Oncology, Institut Curie, Paris, France
| | - Y Kirova
- Department of Radiation Oncology, Institut Curie, Paris, France
- University Versailles St Quentin, St Quentin, France
| |
Collapse
|
3
|
İnan GA, Aral IP, Arslan A, Celik TO, Ozturk HF, Arslan SA, Tezcan Y. Helical tomotherapy experience in breast cancer adjuvant radiotherapy and acute toxicity results. Rep Pract Oncol Radiother 2022; 27:973-981. [PMID: 36632291 PMCID: PMC9826657 DOI: 10.5603/rpor.a2022.0121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Accepted: 11/04/2022] [Indexed: 12/12/2022] Open
Abstract
Background This study aimed to evaluate acute toxicity and oncological outcomes of breast cancer patients who underwent adjuvant radiotherapy (RT) with tomotherapy. Materials and methods The results of 114 patients who underwent adjuvant RT with Tomotherapy device between 17.08.10-12.06.2021 in Ankara Atatürk Training and Research Hospital and Ankara City Hospital were evaluated retrospectively. The primary endpoint of the study was acute adverse events, and the secondary endpoints were overall survival (OS) and disease-free survival (DFS). Results The results of 103 patients who met the inclusion criteria were analyzed. The median follow-up was 21 (range 1-125.8) months. Grade +3 esophagitis was not observed in any patient; no esophagitis was observed in 60 (58.3%) patients. Grade 3 dermatitis was observed in 3 (2.9%) patients. In addition, dermatitis was not observed in 47 (45.6%) patients. The relationship between chest wall volume and esophagitis development was statistically significant (p = 0.006; Z score: -2769). The median OS was 24.1 (range 1-128.5) and median disease-free survival was 21.1 (range 1-125.8) months. Five patients (4.9%) died and 9 patients (8.7%) relapsed. Local recurrence was observed in only 1 (1%) patient. There was a statistically significant correlation between OS and contralateral lung V20 dose [p < 0.001; Spearman Correlation Coefficient (SCC) -406) and heart mean dose (p < 0.001; SCC -370)]. There was a statically significant correlation between DFS and cN (p < 0.001); pN (p < 0.001); heart mean dose (p < 0.001; SCC -351); contralateral lung V5 dose (p = 0.041; SCC -213); contralateral lung V20 dose (p < 0.001; SCC -434). Conclusion Acute toxicity results show improvement in breast cancer adjuvant radiotherapy with helical tomotherapy.
Collapse
Affiliation(s)
- Gonca Altınışık İnan
- Radiation Oncology, Ankara Şehir Hastanesi, Radyasyon Onkolojisi Bölümü, Ankara Yildirim Beyazit Universitesi Tip Fakultesi, Ankara, Turkey
| | - Ipek Pinar Aral
- Radiation Oncology, Ankara Şehir Hastanesi, Radyasyon Onkolojisi Bölümü, Ankara Yildirim Beyazit Universitesi Tip Fakultesi, Ankara, Turkey
| | - Aliye Arslan
- Radiation Oncology, Ankara City Hospital, Cankaya, Turkey
| | | | - Huseyin Furkan Ozturk
- Radiation Oncology, Ankara Şehir Hastanesi, Radyasyon Onkolojisi Bölümü, Ankara Yildirim Beyazit Universitesi Tip Fakultesi, Ankara, Turkey
| | - Suheyla Aytac Arslan
- Radiation Oncology, Ankara Şehir Hastanesi, Radyasyon Onkolojisi Bölümü, Ankara Yildirim Beyazit Universitesi Tip Fakultesi, Ankara, Turkey
| | - Yilmaz Tezcan
- Radiation Oncology, Ankara Şehir Hastanesi, Radyasyon Onkolojisi Bölümü, Ankara Yildirim Beyazit Universitesi Tip Fakultesi, Ankara, Turkey
| |
Collapse
|
4
|
Quesada S, Fenoglietto P, Gourgou S, Lemanski C, Draghici R, Ailleres N, Prunaretty J, Azria D, Bourgier C. Efficacy, safety, and feasibility of volumetric modulated arc therapy for synchronous bilateral breast cancer management. Front Oncol 2022; 12:967479. [PMID: 36059658 PMCID: PMC9436014 DOI: 10.3389/fonc.2022.967479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Accepted: 08/02/2022] [Indexed: 11/13/2022] Open
Abstract
PurposeVolumetric Modulated Arc Therapy (VMAT) exhibits potent advantages regarding target volume coverage and protection of organs at risk, notably in the context of anatomical constraints. Nevertheless, reports concerning VMAT for the treatment of synchronous bilateral breast cancers (SBBC) have been scarce to date. As such, we conducted this observational study to assess efficacy, safety and feasibility of VMAT in SBBC.Materials and MethodsFrom August 2011 to December 2017, 54 consecutive patients with SBBC with or without axillary nodes involvement underwent a treatment protocol containing radiotherapy using VMAT. A total dose (TD) of 52.2Gy in 29 fractions was delivered to breast and internal mammary chain (IMC) nodes Planning Target Volume (PTV) plus, if applicable, a TD of 49.3Gy in 29 fractions to the supra- and infra-clavicular nodes PTV and a TD of 63.22Gy in 29 fractions to tumor boost PTV. Lungs, heart, esophagus, trachea, liver, thyroid and spinal cord were considered as organs at risk. VMAT feasibility and organ at risk sparing were evaluated by treatments planning of the 20 first enrolled patients. Tolerance and patients’ outcome were prospectively monitored by acute/late toxicities records and by the analysis of overall survival (OS), locoregional recurrence-free survival (LRFS) and recurrence-free survival (RFS).ResultsBreast, supraclavicular nodes and boost PTV coverage was adequate with at least 98% of PTV encompassed by more than 95% of the prescribed dose. Less than 90% of IMC PTV was encompassed by 95% of the prescribed dose. Mean lung dose was 12.3Gy (range: 7.7 – 18.7); mean heart dose was 10.7Gy (range: 6.2 – 22.3). Concerning acute toxicities, only 2 patients experienced grade 3 skin toxicity (3.7%) and only 1 patient developed grade 1 pneumonitis. After a median follow-up of 5.3 years, grade 2 fibrosis and/or shrinking was observed in 5 patients (10%), and grade 3 fibrosis in 1 patients (2%). The 5-year LRFS-rate, RFS-rate and OS were 98% [95% CI= 86.12-99.70%], 96% [95% CI= 84.63-98.96%] and 100%, respectively.
Collapse
Affiliation(s)
- Stanislas Quesada
- Faculty of Medicine, University of Montpellier, Montpellier, France
- Department of Radiation Oncology, Montpellier Cancer Institute (ICM), Montpellier, France
| | - Pascal Fenoglietto
- Department of Radiation Oncology, Montpellier Cancer Institute (ICM), Montpellier, France
| | - Sophie Gourgou
- Institute of Cancer Research of Montpellier (IRCM), Montpellier, France
| | - Claire Lemanski
- Department of Radiation Oncology, Montpellier Cancer Institute (ICM), Montpellier, France
| | - Roxana Draghici
- Department of Radiation Oncology, Montpellier Cancer Institute (ICM), Montpellier, France
| | - Norbert Ailleres
- Department of Radiation Oncology, Montpellier Cancer Institute (ICM), Montpellier, France
| | - Jessica Prunaretty
- Department of Radiation Oncology, Montpellier Cancer Institute (ICM), Montpellier, France
| | - David Azria
- Faculty of Medicine, University of Montpellier, Montpellier, France
- Department of Radiation Oncology, Montpellier Cancer Institute (ICM), Montpellier, France
- Institute of Cancer Research of Montpellier (IRCM), Montpellier, France
| | - Céline Bourgier
- Faculty of Medicine, University of Montpellier, Montpellier, France
- Department of Radiation Oncology, Montpellier Cancer Institute (ICM), Montpellier, France
- Institute of Cancer Research of Montpellier (IRCM), Montpellier, France
- *Correspondence: Céline Bourgier,
| |
Collapse
|
5
|
Clinical audit of breast cancer patients treated with helical tomotherapy for irradiation of the internal mammary chain. JOURNAL OF RADIOTHERAPY IN PRACTICE 2022. [DOI: 10.1017/s1460396921000625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Abstract
Aim:
To evaluate efficacy of helical tomotherapy (HT) for treatment of breast cancer with internal mammary lymph node involvement.
Methods:
This is a retrospective clinical audit of planning, dosimetry, toxicity and short-term survival of a cohort of 65 patients. Patients were treated between November 2014 and May 2019. The primary and nodal region was prescribed a dose of 50 Gray (Gy) in 25 fractions, while all cases of breast conserving surgery received a simultaneous integrated boost to a dose of 61 Gy in 25 fractions.
Results:
The 95% coverage for the primary, supraclavicular, internal mammary node and tumour bed was 93·4%, 96·8%, 90·7% and 98·3%, respectively. Mean dose to total lung, heart and contra-lateral breast was 10·6 Gy, 6·92 Gy and 4·32 Gy, respectively. None developed grade III skin or oesophageal toxicity. Twenty-one patients had progression; of which eighteen developed only distant failure while three also had loco-regional recurrence. At a median follow-up of 36 months, the 3-year loco-regional control, disease-free survival and overall survival were 93·5, 73·9 and 85·9%, respectively.
Conclusion:
We report encouraging clinical outcome for patients treated uniformly with HT. The predominant pattern of failure was distant metastases which suggests the need for systemic control intensification.
Collapse
|
6
|
Duane FK, Kerr A, Wang Z, Darby SC, Ntentas G, Aznar MC, Taylor CW. Exposure of the oesophagus in breast cancer radiotherapy: A systematic review of oesophagus doses published 2010-2020. Radiother Oncol 2021; 164:261-267. [PMID: 34626725 DOI: 10.1016/j.radonc.2021.09.032] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 09/18/2021] [Accepted: 09/29/2021] [Indexed: 11/19/2022]
Abstract
BACKGROUND AND PURPOSE Breast cancer radiotherapy can increase the risk of subsequent primary oesophageal cancer, with risk increasing according to oesophagus radiation dose. We describe oesophagus exposure from modern breast cancer regimens and discuss the risks of oesophageal cancer for women irradiated recently. MATERIALS AND METHODS A systematic review was undertaken of oesophagus doses from breast cancer radiotherapy regimens published during 2010-2020. Mean and maximum oesophagus doses were described for different target regions irradiated and different radiotherapy techniques. RESULTS In 112 published regimens from 18 countries, oesophagus doses varied with target region. For partial breast irradiation, average mean oesophagus dose was 0.2 Gy (range 0.1-0.4) in four regimens; maximum dose was not reported. For breast or chest wall radiotherapy, average oesophagus doses were mean 1.8 Gy (range 0.1-10.4) in 24 regimens and maximum 6.7 Gy (range 0.4-14.3) in seven regimens. For radiotherapy including a nodal region, average oesophagus doses were higher: mean 11.4 Gy (range <0.1-29.3) in 61 regimens and maximum 34.4 Gy (range 3.4-51.3) in 55 regimens. Average mean oesophagus doses were >10 Gy for intensity modulated nodal radiotherapy, but lower for other node techniques. CONCLUSIONS Mean oesophagus doses from partial breast and breast/chest wall regimens were usually less than 2 Gy, hence radiation-risks will be very small. However, for radiotherapy including lymph nodes, average mean oesophagus dose of 11.4 Gy may nearly double oesophageal cancer risk. Consideration of oesophageal exposure during nodal radiotherapy planning may reduce the risks of radiation-related oesophageal cancer for women irradiated today.
Collapse
Affiliation(s)
- Frances K Duane
- St. Luke's Radiation Oncology Network, St. Luke's Hospital, Dublin, Ireland; School of Medicine, Trinity College Dublin, Dublin, Ireland; Trinity St James's Cancer Institute, St. James's Hospital, Dublin, Ireland.
| | - Amanda Kerr
- Nuffield Department of Population Health, University of Oxford, Oxford, UK
| | - Zhe Wang
- Nuffield Department of Population Health, University of Oxford, Oxford, UK
| | - Sarah C Darby
- Nuffield Department of Population Health, University of Oxford, Oxford, UK
| | - Georgios Ntentas
- Nuffield Department of Population Health, University of Oxford, Oxford, UK; Guy's and St Thomas' NHS Foundation Trust, Department of Medical Physics, London, UK
| | - Marianne C Aznar
- Manchester Cancer Research Centre, Division of Cancer Sciences, Faculty of Biology, Medicine and Health, University of Manchester, UK
| | - Carolyn W Taylor
- Nuffield Department of Population Health, University of Oxford, Oxford, UK
| |
Collapse
|
7
|
Muthuselvi CA, Bijina TK, Pichandi A. Evaluation of Optimal Combination of Planning Parameters (Field Width, Pitch, and Modulation Factor) in Helical Tomotherapy for Bilateral Breast Cancer. J Med Phys 2021; 45:234-239. [PMID: 33953499 PMCID: PMC8074714 DOI: 10.4103/jmp.jmp_31_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 11/23/2020] [Accepted: 12/03/2020] [Indexed: 11/05/2022] Open
Abstract
Aim: The aim of the study was to find the most balanced plan with an optimal combination of planning parameters in helical tomotherapy (HT) for bilateral breast irradiation by evaluating dosimetric indices and time factors. In particular, we investigated the best combination of field width (FW), pitch, and modulation factor (MF). Materials and Methods: A total of 90 plans (18 plans for each patient) was created in this study, with different combination of planning parameters (FW: 2.5 cm [F1] and 5 cm [F2]; pitch: 0.215 [P1], 0.287 [P2], and 0.43 [P3]; and MF: 2.0 [M1], 2.5 [M2], and 3.0 [M3]). Plans were analyzed using several dosimetric indices: homogeneity index, conformity index, dose near minimum D98%, dose near maximum D2%, and the coverage by D95% of the target. Organ at risk (OAR) doses were evaluated by mean dose, V5Gy and V25Gy for the heart and mean dose V5Gy and V20Gy for both the lungs. Treatment time was also reported for all plans. Results: Reducing FW from 5 cm to 2.5 cm increased the treatment time by 40%–50% and improved homogeneity of the target. Tightening the pitch value from 0.43 to 0.215 improved target as well as OAR doses without increasing the treatment time. Increasing MF from 2 to 3 improved all the dosimetric indices and also increased treatment time. Conclusions: On the basis of our analysis, a plan with FW 5 cm, pitch 0.215, and MF 2.5 can be considered as an optimal combination of planning parameters for bilateral breast irradiation in HT technique.
Collapse
Affiliation(s)
- C A Muthuselvi
- Department of Radiotherapy, Health Care Global Enterprises Ltd., Bengaluru, Karnataka, India
| | - T K Bijina
- Department of Radiotherapy, Health Care Global Enterprises Ltd., Bengaluru, Karnataka, India
| | - A Pichandi
- Department of Radiotherapy, Health Care Global Enterprises Ltd., Bengaluru, Karnataka, India
| |
Collapse
|
8
|
Lin Y, Shueng P, Lin H, Tien H, Lai L. An efficient treatment planning approach to reduce the critical organ dose in volumetric modulated arc therapy for synchronous bilateral breast cancer patients. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2020.108957] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
9
|
Nobnop W, Phakoetsuk P, Chitapanarux I, Tippanya D, Khamchompoo D. Dosimetric comparison of TomoDirect, helical tomotherapy, and volumetric modulated arc therapy for postmastectomy treatment. J Appl Clin Med Phys 2020; 21:155-162. [PMID: 32715634 PMCID: PMC7497934 DOI: 10.1002/acm2.12989] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 06/16/2020] [Accepted: 07/01/2020] [Indexed: 11/09/2022] Open
Abstract
Purpose To compare dose to the targets and organs at risk (OARs) in different situations for postmastectomy patients who require radiation to the chest wall with or without regional nodal irradiation when using three treatment techniques. Methods and materials Thirty postmastectomy radiotherapy (PMRT) patients previously treated by helical tomotherapy (HT) at our institution were identified for the study. The treatment targets were classified in three situations which consisted of, the chest wall (CW) only, the chest wall plus supraclavicular lymph nodes (CW + SPC), and the chest wall plus supraclavicular and whole axillary lymph nodes irradiation (CW + SPC+AXLN). The volumetric modulated arc therapy (VMAT) plans and Tomodirect (TD) plans were created for each patient and compared with HT treatment plans which had been treated. The target coverage, dose homogeneity index (HI), conformity index (CI), and dose to OARs were analyzed. The quality scores were used to evaluate the appropriate technique for each situation from multiparameter results. Results The HT and VMAT plans showed the advantage of target coverage and OARs sparing for the chest wall with regional nodal irradiation with the higher plan quality scores when compared with TD plans. However, TD plans demonstrated superiority to contralateral breast sparing for the chest wall without regional nodal situation reaching the highest of planned quality scores. HT plans showed better HI, CI, and target coverage (P < 0.01) than TD and VMAT plans for all patient situations. Volumetric modulated arc therapy plans generated better contralateral breast and heart sparing at a lower dose than HT. Conclusion The arc‐based techniques, HT and VMAT plans, provided an advantage for complex targets in terms of target coverage and OARs sparing. However, the static beam TD plan was superior for contralateral organ sparing meanwhile achieving good target coverage for the chest wall without regional node situations.
Collapse
Affiliation(s)
- Wannapha Nobnop
- Division of Radiation Oncology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.,Northern Thai Research Group of Radiation Oncology (NTRG-RO), Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | | | - Imjai Chitapanarux
- Division of Radiation Oncology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.,Northern Thai Research Group of Radiation Oncology (NTRG-RO), Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.,Faculty of Medicine, Chiang Mai Cancer Registry, Maharaj Nakorn Chiang Mai Hospital, Chiang Mai University, Chiang Mai, Thailand
| | - Damrongsak Tippanya
- Division of Radiation Oncology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | | |
Collapse
|
10
|
Huang J, Wu X, Lin X, Shi J, Ma Y, Duan S, Huang X. Evaluation of fixed-jaw IMRT and tangential partial-VMAT radiotherapy plans for synchronous bilateral breast cancer irradiation based on a dosimetric study. J Appl Clin Med Phys 2019; 20:31-41. [PMID: 31483573 PMCID: PMC6753728 DOI: 10.1002/acm2.12688] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 07/03/2019] [Accepted: 07/10/2019] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To investigate the fixed-jaw intensity-modulated radiotherapy (F-IMRT) and tangential partial volumetric modulated arc therapy (tP-VMAT) treatment plans for synchronous bilateral breast cancer (SBBC). MATERIALS AND METHOD Twelve SBBC patients with pTis-2N0M0 stages who underwent whole-breast irradiation after breast-conserving surgery were planned with F-IMRT and tP-VMAT techniques prescribing 42.56 Gy (2.66 Gy*16f) to the breast. The F-IMRT used 8-12 jaw-fixed tangential fields with single (sF-IMRT) or two (F-IMRT) isocenters located under the sternum or in the center of the left and right planning target volumes (PTVs), and tP-VMAT used 4 tangential partial arcs with two isocenters located in the center of the left and right PTVs. Plan evaluation was based on dose-volume histogram (DVH) analysis. Dosimetric parameters were calculated to evaluate plan quality; total monitor units (MUs), and the gamma analysis for patient-specific quality assurance (QA) were also evaluated. RESULTS For PTVs, the three plans had similar Dmean and conformity index (CI) values. F-IMRT showed a slightly better target coverage according to the V100% values and demonstrated an obvious reduction in V105% and Dmax compared with the values observed for sF-IMRT and tP-VMAT. Compared with tP-VMAT, sF-IMRT was slightly better in terms of V100% , V105% and Dmax . In addition, F-IMRT achieved the best homogeneity index (HI) values for PTVs. Concerning healthy tissue, tP-VMAT had an advantage in minimizing the high dose volume. The MUs of the tP-VMAT plan were decreased approximately 1.45 and 1 times compared with the sF-IMRT and F-IMRT plans, respectively, and all plans passed QA. For the lungs, heart and liver, F-IMRT achieved the smallest values in terms of Dmean and showed a significant difference compared with tP-VMAT. Simultaneously, sF-IMRT was also superior to tP-VMAT. For the coronary artery, tP-VMAT achieved the lowest Dmean , while the value for F-IMRT was 2.24% lower compared with sF-IMRT. For all organs at risk (OARs), tP-VMAT was superior at the high dose level. In contrast, sF-IMRT and F-IMRT were obviously superior at the low dose level. The sF-IMRT and F-IMRT plans showed consistent trends. CONCLUSION All treatment plans for the provided techniques were of high quality and feasible for SBBC patients. However, we recommend F-IMRT with a single isocenter as a priority technique because of the tremendous advantage of local hot spot control in PTVs and the reduced dose to OARs at low dose levels. When the irradiated dose to the lungs and heart exceed the clinical restriction, two isocenter F-IMRT can be used to maximize OAR sparing. Additionally, tP-VMAT can be adopted for improving cold spots in PTVs or high-dose exposure to normal tissue when the interval between PTVs is narrow.
Collapse
Affiliation(s)
- Jiang‐Hua Huang
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research CenterSun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
- Department of Radiation OncologySun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
| | - Xiu‐Xiu Wu
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research CenterSun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
- Department of Radiation OncologySun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
| | - Xiao Lin
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research CenterSun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
- Department of Breast Tumor CenterSun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
| | - Jun‐Tian Shi
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research CenterSun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
- Department of Radiation OncologySun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
| | - Yu‐Jia Ma
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research CenterSun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
- Department of Radiation OncologySun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
| | - Song Duan
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research CenterSun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
- Department of Radiation OncologySun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
| | - Xiao‐Bo Huang
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research CenterSun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
- Department of Radiation OncologySun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
- Department of Breast Tumor CenterSun Yat‐Sen Memorial Hospital, Sun Yat‐Sen UniversityGuangzhouChina
| |
Collapse
|
11
|
Chitapanarux I, Nobnop W, Tippanya D, Sripan P, Chakrabandhu S, Klunklin P, Onchan W, Jia-Mahasap B, Tharavichitkul E. Clinical outcomes and dosimetric study of hypofractionated Helical TomoTherapy in breast cancer patients. PLoS One 2019; 14:e0211578. [PMID: 30703145 PMCID: PMC6355009 DOI: 10.1371/journal.pone.0211578] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Accepted: 01/16/2019] [Indexed: 11/23/2022] Open
Abstract
We present a single center’s experience of treatment outcomes and dosimetric parameters for breast cancer patients treated with hypofractionated Helical TomoTherapy (HT). This is a retrospective study of one hundred and thirty-six patients with invasive breast cancer treated between March 2012 and October 2016. Dosimetric parameters and 3-year loco-regional failure free survival (LRFFS) were analyzed. Dose to ipsilateral lung, heart and contralateral breast as well as acute and late toxicities were recorded. The median follow-up time is 45 months (range: 5–83). Two patients had loco-regional failure. The 3-year LRFFS was 99%. Acute grade 1 and 2 skin toxicities occurred in 95% and 1%, respectively. Coverage of the target volumes was achieved with the mean ± standard deviation (SD) of homogeneity and conformity index being 0.1 ± 0.04, and 0.8 ± 0.07, respectively. Dose to ipsilateral lung, contralateral breast, and heart was also within the limited constraints regardless of the complexity of target volumes. Only two percent of patients experienced late grade 2 skin toxicity. No late grade 2 subcutaneous tissue toxicity was found. Nine percent of patients developed late grade 1 lung toxicity. Hypofractionated radiotherapy using Helical TomoTherapy in breast irradiation provides excellent 3-year LRFFS and minimal acute and late toxicities. A careful, longer follow-up of healthy tissue effects to lung, heart, and contralateral breast is warranted.
Collapse
Affiliation(s)
- Imjai Chitapanarux
- Division of Radiation Oncology, Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.,Northern Thai Research Group of Radiation Oncology (NTRG-RO), Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.,Chiang Mai Cancer Registry, Maharaj Nakorn Chiang Mai Hospital, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Wannapha Nobnop
- Division of Radiation Oncology, Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Damrongsak Tippanya
- Division of Radiation Oncology, Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Patumrat Sripan
- Northern Thai Research Group of Radiation Oncology (NTRG-RO), Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Somvilai Chakrabandhu
- Division of Radiation Oncology, Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Pitchayaponne Klunklin
- Division of Radiation Oncology, Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Wimrak Onchan
- Division of Radiation Oncology, Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Bongkot Jia-Mahasap
- Division of Radiation Oncology, Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Ekkasit Tharavichitkul
- Division of Radiation Oncology, Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| |
Collapse
|
12
|
Lancellotta V, Chierchini S, Perrucci E, Saldi S, Falcinelli L, Iacco M, Zucchetti C, Palumbo I, Bini V, Aristei C. Skin toxicity after chest wall/breast plus level III-IV lymph nodes treatment with helical tomotherapy. Cancer Invest 2018; 36:504-511. [PMID: 30516084 DOI: 10.1080/07357907.2018.1545854] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
INTRODUCTION To evaluate the incidence of toxicity in breast cancer with helical tomotherapy (HT). MATERIALS AND METHODS 51 patients with breast cancer were assigned to postoperative radiotherapy by means of HT to the chest wall/breast plus draining nodes. During HT treatment, toxicity was monitored and were assessed using the Common Terminology Criteria for Adverse Events 4.0 scale. RESULTS Acute skin G3 toxicity observed in 1.9% cases. No acute or late G4 toxicity was observed. At a median follow-up of 21 months 2 patients have late G1 toxicity. CONCLUSIONS HT was associated with a low incidence of low-grade skin toxicity.
Collapse
Affiliation(s)
- Valentina Lancellotta
- a Radiation Oncology Section , Department of Surgical and Biomedical Sciences , University of Perugia and Perugia General Hospital , Italy
| | | | | | | | | | - Martina Iacco
- d Medical Physics Unit, Perugia General Hospital , Italy
| | | | - Isabella Palumbo
- a Radiation Oncology Section , Department of Surgical and Biomedical Sciences , University of Perugia and Perugia General Hospital , Italy
| | - Vittorio Bini
- e Internal Medicine, Endocrine and Metabolic Science Section , University of Perugia , Perugia , Italy
| | - Cynthia Aristei
- a Radiation Oncology Section , Department of Surgical and Biomedical Sciences , University of Perugia and Perugia General Hospital , Italy
| |
Collapse
|
13
|
Kim SJ, Lee MJ, Youn SM. Radiation therapy of synchronous bilateral breast carcinoma (SBBC) using multiple techniques. Med Dosim 2017; 43:55-68. [PMID: 28988893 DOI: 10.1016/j.meddos.2017.08.003] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Revised: 07/22/2017] [Accepted: 08/18/2017] [Indexed: 11/30/2022]
Abstract
The purpose of this study was to establish intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans for synchronous bilateral breast cancer (SBBC) and to compare those plans with the previous treatment plans using 3D conformal radiation therapy (3DCRT). The differences among the treatments were also statistically compared regarding dosimetry distribution and treatment efficiency. The research was conducted with 10 SBBC patients. The study established IMRT (12 fields with a single isocenter) and VMAT (2 partial arcs with a single isocenter) treatment plans for SBBC patients and then compared those plans with 3DCRT (8 fields with multiple isocenters). The plans were evaluated based on a dose-volume histogram analysis. For planning target volumes (PTVs), the mean doses and the values of V95%, V105%, conformity index, and homogeneity index were reported. For the organs at risk, the analysis included the mean dose, maximum dose, and VXGy, depending on the organs (lungs, heart, and liver). To objectively evaluate the efficiency of the treatment plans, each plan's beam times, treatment times (including set-up time), and monitor units were compared. Tukey test and one-way analysis of variance were used to compare the PTV and organs at risk values of the 3 techniques. Additionally, the independent-samples t-test was used to compare the 2 techniques (IMRT and VMAT) based on the values of Rt. PTV and Lt. PTV (p < 0.05). For PTV dose distribution, IMRT showed increases of approximately 1.2% in Dmean and of approximately 5.7% in V95% dose distribution compared with 3DCRT. In comparison to VMAT, 3DCRT showed about 3.0% higher dose distribution in Dmean and V95%. IMRT was the best in terms of conformity index and homogeneity index (p < 0.05), whereas 3DCRT and VMAT did not significantly differ from each other. In terms of dose distribution on lungs, heart, and liver, the percentage of volume at high doses such as V30Gy and V40Gy was approximately 70% lower for IMRT and approximately 40% lower for VMAT than for 3DCRT. For distribution volumes of low doses such as V5% and V10%, that for 3DCRT was approximately 60% smaller than for IMRT and approximately 70% smaller than for VMAT. Comparison between IMRT and VMAT showed that the IMRT was superior in all distribution factors. VMAT showed better treatment efficiency than 3DCRT or IMRT. Among the SBBC radiotherapy treatment plans, IMRT was superior to 3DCRT and VMAT in terms of PTV dose distribution, whereas VMAT showed the most outstanding treatment efficiency.
Collapse
Affiliation(s)
- Sung Jin Kim
- Department of Radiation Oncology, Eulji University Hospital, Eulji University, College of Medicine, Daejeon, Republic of Korea; Department of Physics, Yeung Nam University, Daegu, Republic of Korea
| | - Mi Jo Lee
- Department of Radiation Oncology, Eulji University Hospital, Eulji University, College of Medicine, Daejeon, Republic of Korea
| | - Seon Min Youn
- Department of Radiation Oncology, Eulji University Hospital, Eulji University, College of Medicine, Daejeon, Republic of Korea.
| |
Collapse
|
14
|
Farooqi AS, Sun TL, Thang S, Shaitelman SF. Treatment of bilateral breast cancer and regional nodes using an opposed lateral beam arrangement. Pract Radiat Oncol 2017; 7:e385-e389. [PMID: 28867548 DOI: 10.1016/j.prro.2017.07.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2017] [Revised: 06/24/2017] [Accepted: 07/01/2017] [Indexed: 11/16/2022]
Affiliation(s)
- Ahsan S Farooqi
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Tzouh-Liang Sun
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Sandy Thang
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Simona F Shaitelman
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas.
| |
Collapse
|
15
|
Nagai A, Shibamoto Y, Yoshida M, Inoda K, Kikuchi Y. Intensity-modulated radiotherapy using two static ports of tomotherapy for breast cancer after conservative surgery: dosimetric comparison with other treatment methods and 3-year clinical results. JOURNAL OF RADIATION RESEARCH 2017; 58:529-536. [PMID: 28339844 PMCID: PMC5570131 DOI: 10.1093/jrr/rrw132] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/05/2016] [Revised: 10/23/2016] [Indexed: 06/06/2023]
Abstract
This study investigated the differences in dose-volume parameters for the breast and normal tissues during TomoDirectTM (TD) intensity-modulated radiation therapy (IMRT), TD-3D conformal radiotherapy (3DCRT) and 3DCRT plans, all using two beams, and analyzed treatment outcomes of two-beam TD-IMRT for breast cancer after breast-conserving surgery. Between August 2011 and January 2015, 152 patients were treated using two-beam TD-IMRT with 50 Gy/25 fractions. Among them, 20 patients with left-sided breast cancer were randomly chosen, and two-beam TD-IMRT, TD-3DCRT and 3DCRT plans were created for each patient. The homogeneity and conformity indices and various dose-volume parameters for the planning target volume and OARs were evaluated. Clinical outcomes were evaluated at 3 years. Toxicities were evaluated using the Common Terminology Criteria for Adverse Events version 4.0. TD-IMRT and TD-3DCRT showed better whole-breast coverage than 3DCRT (P < 0.001). Most of the mean values of dosimetric endpoints for OARs were better in TD-IMRT than in TD-3DCRT and 3DCRT. Overall survival rates were 97.7% and local control rates were 99.1% at 3 years. Regional control and distant metastasis control rates at 3 years were 98.6% and 96.8%, respectively. Twenty-four of the 152 patients had Grade 2 or higher acute radiation dermatitis. Four patients (4/146 = 2.7%) had Grade 2 radiation pneumonitis. There were no late adverse events of Grade 2 or higher. Two-beam TD-IMRT appeared to yield better dose distribution for whole-breast external-beam radiation therapy than TD-3DCRT and two-beam 3DCRT. The treatment appeared to provide low skin toxicity and acceptable tumor control.
Collapse
Affiliation(s)
- Aiko Nagai
- Radiation Therapy Center, Fukui Saiseikai Hospital, 7-1, Funabashi, Wadanaka-cho, Fukui 918-8503, Japan
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| | - Yuta Shibamoto
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| | - Masanori Yoshida
- Radiation Therapy Center, Fukui Saiseikai Hospital, 7-1, Funabashi, Wadanaka-cho, Fukui 918-8503, Japan
| | - Koji Inoda
- Department of Radiological Technology, Fukui Saiseikai Hospital, 7-1, Funabashi, Wadanaka-cho, Fukui 918-8503, Japan
| | - Yuzo Kikuchi
- Radiation Therapy Center, Fukui Saiseikai Hospital, 7-1, Funabashi, Wadanaka-cho, Fukui 918-8503, Japan
| |
Collapse
|
16
|
Duma MN, Heinrich C, Schönknecht C, Chizzali B, Mayinger M, Devecka M, Kampfer S, Combs SE. Helical TomoTherapy for locally advanced or recurrent breast cancer. Radiat Oncol 2017; 12:31. [PMID: 28129767 PMCID: PMC5273793 DOI: 10.1186/s13014-016-0736-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2016] [Accepted: 12/01/2016] [Indexed: 12/25/2022] Open
Abstract
Purpose We report our experience of using helical tomotherapy (HT) to treat large and irregular shaped loco-regional advanced breast cancer target volumes embracing various organs at risk. Patients and methods We retrospectively analyzed 26 patients treated for very large, irregular shaped breast cancers. Patients were treated either with the intent to achieve local control in a primary setting (n = 14) or in a reirradiation setting (n = 12). The recurrence group was heavily pretreated with systemic therapy. Tumors were characterized by wide infiltration of the skin, encompassing mostly a complete hemithorax. The primary group underwent irradiation of supraclavicular, infraclavicular, axillary and parasternal lymphonodal region. Radiotherapy was combined with chemotherapy (n = 11). We assessed the PTV volume and its craniocaudal extension, the dose to the organs at risk, acute toxicity and survival. Results Median PTV was 2276 cm3 (1476–6837 cm3) with a median cranio-caudal extension of 28 cm (15–52 cm). The median dose to PTV was 40 Gy (32–60Gy). HT could be carried out in all patients without interruption. The acute toxicities were mild to moderate. The median LRFS and OS after radiotherapy was 21 and 57 months for the primary group versus 10 and 11 months for the recurrence group. Median PFS was 18 months (primary group) and 7 months (recurrence group). Conclusions HT is feasible for advanced thorax embracing target volumes with acceptable acute toxicity. Both curative and palliative indications can be considered good indications based on treatment volume and anatomical constellation.
Collapse
Affiliation(s)
- M N Duma
- Department of Radiation Oncology, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Str. 22, 81675, München, Germany. .,Institute of Innovative Radiotherapy (iRT), Helmholtz Zentrum München, München, Germany.
| | - C Heinrich
- Department of Radiation Oncology, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Str. 22, 81675, München, Germany.,Praxis für Strahlentherapie, Hausham, Germany
| | - C Schönknecht
- Department of Radiation Oncology, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Str. 22, 81675, München, Germany
| | - B Chizzali
- Department of Radiation Oncology, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Str. 22, 81675, München, Germany
| | - M Mayinger
- Department of Radiation Oncology, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Str. 22, 81675, München, Germany
| | - M Devecka
- Department of Radiation Oncology, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Str. 22, 81675, München, Germany
| | - S Kampfer
- Department of Radiation Oncology, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Str. 22, 81675, München, Germany
| | - S E Combs
- Department of Radiation Oncology, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Str. 22, 81675, München, Germany.,Institute of Innovative Radiotherapy (iRT), Helmholtz Zentrum München, München, Germany
| |
Collapse
|
17
|
Kaidar-Person O, Kostich M, Zagar TM, Jones E, Gupta G, Mavroidis P, Das SK, Marks LB. Helical tomotherapy for bilateral breast cancer: Clinical experience. Breast 2016; 28:79-83. [DOI: 10.1016/j.breast.2016.05.004] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2016] [Revised: 05/11/2016] [Accepted: 05/11/2016] [Indexed: 01/01/2023] Open
|
18
|
Seppälä J, Heikkilä J, Myllyoja K, Koskela K. Volumetric modulated arc therapy for synchronous bilateral whole breast irradiation - A case study. Rep Pract Oncol Radiother 2015; 20:398-402. [PMID: 26549999 DOI: 10.1016/j.rpor.2015.05.011] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2014] [Revised: 02/13/2015] [Accepted: 05/24/2015] [Indexed: 01/08/2023] Open
Abstract
PURPOSE The treatment planning of bilateral breast irradiation (BBI) is a challenging task. The overlapping of tangential fields is usually unavoidable without compromising the target coverage. The purpose of this study was to investigate the technical feasibility and benefits of a single isocentre volumetric modulated arc therapy (VMAT) in BBI. METHODS AND MATERIALS Two women with bilateral breast cancer were included in this case study. The first patient (Pat#1) underwent a bilateral breast-conserving surgery and sentinel lymph node biopsy. The second patient (Pat#2) underwent a bilateral ablation and axillary lymph node dissection. Planning target volumes (PTV) and organs at risk were delineated on CT images. VMAT plans were created with four (two for both sides, Pat#1) or two (one for each breast, Pat#2) separate VMAT fields. Subsequently, traditional tangential field plans were generated for each patient and the dosimetric parameters were compared. RESULTS The treatment times of the patients with VMAT were less than 15 min with daily CBCT imaging. When compared to the standard tangential field technique, the VMAT plans improved the PTV dose coverage and dose homogeneity with improved sparing of lungs and heart. With traditional field arrangement, the overlapping of the tangential fields was inevitable without significantly compromising the target coverage, whereas with VMAT the hotspots were avoided. The patients were treated with the VMAT technique and no acute skin toxicity was observed with either of the patients. CONCLUSIONS A single isocentre VMAT technique has been implemented clinically for BBI. With the VMAT techniques, the dose delivery was quick and the hotspots in the field overlapping areas were avoided. The PTV dose coverage was superior in VMAT plans when compared with conventional tangential technique plans.
Collapse
Affiliation(s)
- Jan Seppälä
- Cancer Center, Kuopio University Hospital, Kuopio, Finland
| | - Janne Heikkilä
- Cancer Center, Kuopio University Hospital, Kuopio, Finland
| | - Kimmo Myllyoja
- Cancer Center, Kuopio University Hospital, Kuopio, Finland
| | | |
Collapse
|
19
|
Kang DG, Park SI, Kim SH, Chung MJ, Lee KM, Lee JH. Evaluation of the Flash effect in breast irradiation using TomoDirect: an investigational study. JOURNAL OF RADIATION RESEARCH 2015; 56:397-404. [PMID: 25672612 PMCID: PMC4380062 DOI: 10.1093/jrr/rru118] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/21/2014] [Revised: 09/25/2014] [Accepted: 11/05/2014] [Indexed: 06/04/2023]
Abstract
Flash is a specified function in TomoDirect that enables beam expansion by opening additional leaves to the target. This study assessed the theoretical dose distribution resulting from Flash in breast irradiation using TomoDirect. A cylindrical phantom that enabled dose distribution of the breast was used for verifying the effect of planning target volume (PTV) contouring and Flash. A total of 18 Gy in 10 fractions were prescribed to the PTV. Five PTVs were then created by Contracting this contour by 0, 1, 2, 3, 4 and 5 mm, giving PTV-x. Flash ±x is defined by opening x (number) of the leaves. The Flash effect in the air was compared with each set-up error of 5, 10 and 15 mm, respectively. The minimum PTV dose from PTV-1 to PTV-3 increased from 13.88 Gy to 15.86 Gy. In contrast, Dmin in PTV-4 and PTV-5 was 17.80 Gy in 98.88% of the prescription dose. Without Flash, when 5-, 10- and 15-mm set-up errors applied in the PTV, relative doses of 87.88, 23.73 and 7.94% were observed, respectively. However, in Flash 3, which was equal to the usual air margin of 1.875 cm, a relative dose of 104.24% ± 0.30% was observed, irrespective of set-up errors (5 mm to 15 mm). Flash opening is useful for countervailing set-up errors in breast cancer patients who receive breast irradiation with TomoDirect.
Collapse
Affiliation(s)
- Dae Gyu Kang
- Department of Radiation Oncology, St Vincent's Hospital, the Catholic University of Korea, 93, Ji-dong, Paldal-gu, Suwon, Gyeonggi-do, Korea Department of Biomedical Engineering, Electronic Engineering, Jeju National University of Korea, Jeju-si, Jeju Special Self-Governing Province, Korea
| | - Sung Ill Park
- Department of Medical Physics, Kyong-gi University of Korea, Yeongtong-gu, Suwon, Gyeonggi-do, Korea
| | - Sung Hwan Kim
- Department of Radiation Oncology, St Vincent's Hospital, the Catholic University of Korea, 93, Ji-dong, Paldal-gu, Suwon, Gyeonggi-do, Korea
| | - Mi Joo Chung
- Department of Radiation Oncology, St Vincent's Hospital, the Catholic University of Korea, 93, Ji-dong, Paldal-gu, Suwon, Gyeonggi-do, Korea
| | - Kwang-Man Lee
- Department of Biomedical Engineering, Electronic Engineering, Jeju National University of Korea, Jeju-si, Jeju Special Self-Governing Province, Korea
| | - Jong Hoon Lee
- Department of Radiation Oncology, St Vincent's Hospital, the Catholic University of Korea, 93, Ji-dong, Paldal-gu, Suwon, Gyeonggi-do, Korea
| |
Collapse
|
20
|
Yang ZX, Shen JT, Li YP, Zhao K, Shi CH, Xiao Y, Yu JJ, Guo WD, Li CC, Wang YQ, Li XL. Helical tomotherapy for cancer treatment: a rapid health technology assessment. J Evid Based Med 2014; 7:192-218. [PMID: 25156336 DOI: 10.1111/jebm.12109] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2013] [Accepted: 06/09/2014] [Indexed: 02/05/2023]
Abstract
OBJECTIVES Helical tomotherapy (HT) can be applied to treat complex malignant cancer with high-precise radiotherapy, and it can reduce the damage to normal tissues and improve treatment effects. But the procurement of HT must be approved by relevant departments of administration affairs. This study, appointed by the National Health and Family Planning Commission of China and undertook by the National Health Development Research Center and the Chinese Evidence-Based Medicine Centre, was aimed to rapidly assess the effectiveness, safety, costs, and applicability of HT, so as to provide currently available best evidence for decision-makers of health policies. METHODS We electronically searched databases including PubMed, EMbase, The Cochrane Library, CNKI, WanFang Data, VIP, CBM, and other professional websites. Two reviewer independently screened literature according to the inclusion and exclusion criteria, extracted data, assessed quality, and then performed descriptive analysis. RESULTS (i) We finally included 150 studies, encompassing 5 HTAs, 18 CCTs, and 127 observational studies. (ii) The included HTAs were published during 2006-2009, providing fairly less evidence of low quality and the results of 145 primary studies showed that: HT had been used mainly in the treatments of 14 kinds of cancer, with low total toxicity and high survival rates. Although the quality of the included studies was poor, there was much evidence about prostate cancer, head and neck cancer, nasopharynx cancer, cervical cancer, lung cancer and liver cancer, with enough sample and fairly reliable results in HT efficacy and safety. And (iii) a total of 56 clinical trials were registered in Clinicaltrials.gov, most of which were registered by the occident. Among them, 9 were completed but the results had not been published yet. CONCLUSIONS The evidence of this study showed that, HT is safe and effective in clinic. But the abovementioned conclusion needs to be verified by conducting more high-quality studies with long-term follow-up. The costs of HT in procurement, maintenance, and application are high; and the skills, training, and qualification of operators are required. We suggest that the procurement of HT should be reduced; it should be allocated rationally and effectively used after comprehensive assessment in China's cancer epidemiology characteristics, health resource allocation, disease burden, medical service level, etc.; and also high-quality studies with long-term follow-up should be financially supported on the basis of establishing projects, so as to provide local evidence and consistently guide and improve scientific decision-making.
Collapse
Affiliation(s)
- Zong Xia Yang
- Chinese Evidence-Based Medicine Centre, West China Hospital, Sichuan University, Chengdu, China
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Poortmans P, Marsiglia H, De Las Heras M, Algara M. Clinical and technological transition in breast cancer. Rep Pract Oncol Radiother 2013; 18:345-52. [PMID: 24416578 DOI: 10.1016/j.rpor.2013.08.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2013] [Revised: 07/08/2013] [Accepted: 08/05/2013] [Indexed: 12/01/2022] Open
Abstract
This article is a summary of the conference "Clinical and technological transition in breast cancer" that took place in the Congress of the Spanish Society of Radiation Oncology, placed in Vigo (Spain) on June 21, 2013. Hugo Marsiglia and Philip Poortmanns were the speakers, the first discussed about "Clinical and technological transition" and the second about "EORTC clinical trials and protocols".
Collapse
Affiliation(s)
- Philip Poortmans
- Radiotherapy Department, Institute Verbeeten, Tilburg, The Netherlands
| | - Hugo Marsiglia
- Radiotherapy Department, Instituve Gustave Roussy, Villejuif, France
| | | | - Manuel Algara
- Radiotherapy Department, Parc de Salut Mar, Barcelona, Spain
| |
Collapse
|
22
|
Chira C, Kirova YM, Liem X, Campana F, Peurien D, Amessis M, Fournier-Bidoz N, Pierga JY, Dendale R, Bey P, Fourquet A. Helical tomotherapy for inoperable breast cancer: a new promising tool. BIOMED RESEARCH INTERNATIONAL 2013; 2013:264306. [PMID: 24078909 PMCID: PMC3775426 DOI: 10.1155/2013/264306] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2013] [Revised: 07/07/2013] [Accepted: 07/11/2013] [Indexed: 12/21/2022]
Abstract
BACKGROUND We investigated the feasibility of helical tomotherapy (HT) for inoperable large breast tumors, after failing to achieve adequate treatment planning with conformal radiation techniques. MATERIAL AND METHODS Five consecutive patients with locally advanced breast cancer (LABC) were treated by preoperative HT. All patients received up-front chemotherapy before HT. Irradiated volumes included breast and nodal areas (45-50 Gy) in 4 patients. One patient received a simultaneous integrated boost (55 Gy) to gross tumor volume (GTV) without lymph node irradiation. Acute toxicity was assessed with Common Toxicity Criteria for Adverse Events v.4. Patients were evaluated for surgery at the end of treatment. RESULTS Patients were staged IIB to IIIC (according to the AJCC staging system 2010). HT was associated in 4 patients with concomitant chemotherapy (5-fluorouracil and vinorelbine). Two patients were scored with grade 3 skin toxicity (had not completed HT) and one with grade 3 febrile neutropenia. One patient stopped HT with grade 2 skin toxicity. All patients were able to undergo mastectomy at a median interval of 43 days (31-52) from HT. Pathological partial response was seen in all patients. CONCLUSIONS HT is feasible with acceptable toxicity profiles, potentially increased by chemotherapy. These preliminary results prompt us to consider a phase II study.
Collapse
Affiliation(s)
- Ciprian Chira
- Department of Radiation Oncology, Institut Curie, 26 rue d'Ulm, 75005 Paris, France
| | - Youlia M. Kirova
- Department of Radiation Oncology, Institut Curie, 26 rue d'Ulm, 75005 Paris, France
| | - Xavier Liem
- Department of Radiation Oncology, Institut Curie, 26 rue d'Ulm, 75005 Paris, France
| | - François Campana
- Department of Radiation Oncology, Institut Curie, 26 rue d'Ulm, 75005 Paris, France
| | - Dominique Peurien
- Department of Medical Physics, Institut Curie, 26 rue d'Ulm, 75005 Paris, France
| | - Malika Amessis
- Department of Medical Physics, Institut Curie, 26 rue d'Ulm, 75005 Paris, France
| | | | - Jean-Yves Pierga
- Department of Medical Oncology, Institut Curie, 26 rue d'Ulm, 75005 Paris, France
| | - Rémi Dendale
- Department of Radiation Oncology, Institut Curie, 26 rue d'Ulm, 75005 Paris, France
| | - Pierre Bey
- Department of Radiation Oncology, Institut Curie, 26 rue d'Ulm, 75005 Paris, France
| | - Alain Fourquet
- Department of Radiation Oncology, Institut Curie, 26 rue d'Ulm, 75005 Paris, France
| |
Collapse
|
23
|
Intensity modulated radiotherapy (IMRT) with simultaneous integrated boost (SIB) in a patient with left breast cancer and pectus excavatum. Clin Transl Oncol 2012; 14:747-54. [PMID: 22855154 DOI: 10.1007/s12094-012-0862-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2011] [Accepted: 12/16/2011] [Indexed: 10/28/2022]
Abstract
INTRODUCTION Pectus excavatum is a frequent anomaly. It represents a challenge for adjuvant radiotherapy in the conservative treatment of breast cancer. Primary objective of this study is to compare dosimetric outcomes, normal tissue complication probability (NTCP), and integral dose using four radiation techniques. Secondary objective is to describe acute toxicity and setup errors. METHODS AND MATERIALS A 57-year-old female patient with an inner quadrant, left breast, ductal carcinoma in situ, was identified. Whole breast was prescribed with 50 Gy in 25 fractions. Boost planning target volume (PTV) was prescribed with 60 Gy in 30 fractions for sequential boost (SB) plans or 57.5 Gy in 25 fractions in the simultaneous integrated boost (SIB) plan. All plans were normalized to deliver 47.5 Gy to 95 % of the breast PTV. Daily image-guided radiotherapy (IGRT) was performed. Setup deviations were described. RESULTS Constraints were not accomplished for heart when using intensity modulated radiotherapy (IMRT) + SB or conformal radiotherapy with three photon fields and SB. Left lung constraint was not achieved by any of the techniques in comparison. IMRT + SIB and conformal photons and electrons + SB plan were closer to the objective. Integral doses were lower with IMRT for heart and ipsilateral lung; however, it were higher for contralateral breast and lung. Coverage and tumoral conformity indexes were similar for all techniques in comparison. Greater inhomogeneity was observed with the photons and electrons + SB. IMRT + SIB treatment was administered daily with grade I skin toxicity. The highest setup error was observed in Y direction. CONCLUSION Planning target volume coverage was similar with the four techniques. Homogeneity was superior with both IMRT plans. A good balance between dose constraints for organs at risk, PTV coverage, homogeneity, and NTCP was observed with IMRT + SIB. The documented daily setup error justifies the use of online IGRT.
Collapse
|