• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4613498)   Today's Articles (1787)   Subscriber (49388)
For: Sohlberg AO, Kajaste MT. Fast Monte Carlo-simulator with full collimator and detector response modelling for SPECT. Ann Nucl Med 2011;26:92-8. [PMID: 22033783 DOI: 10.1007/s12149-011-0550-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2011] [Accepted: 10/13/2011] [Indexed: 10/16/2022]
Number Cited by Other Article(s)
1
Budenkotte T, Apostolova I, Opfer R, Krüger J, Klutmann S, Buchert R. Automated identification of uncertain cases in deep learning-based classification of dopamine transporter SPECT to improve clinical utility and acceptance. Eur J Nucl Med Mol Imaging 2024;51:1333-1344. [PMID: 38133688 PMCID: PMC10957699 DOI: 10.1007/s00259-023-06566-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 12/08/2023] [Indexed: 12/23/2023]
2
Tran-Gia J, Denis-Bacelar AM, Ferreira KM, Robinson AP, Bobin C, Bonney LM, Calvert N, Collins SM, Fenwick AJ, Finocchiaro D, Fioroni F, Giannopoulou K, Grassi E, Heetun W, Jewitt SJ, Kotzasarlidou M, Ljungberg M, Lourenço V, McGowan DR, Mewburn-Crook J, Sabot B, Scuffham J, Sjögreen Gleisner K, Solc J, Thiam C, Tipping J, Wevrett J, Lassmann M. On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT/CT calibration: a European multi-centre evaluation. EJNMMI Phys 2023;10:73. [PMID: 37993667 PMCID: PMC10665282 DOI: 10.1186/s40658-023-00582-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Accepted: 09/25/2023] [Indexed: 11/24/2023]  Open
3
Pells S, Cullen DM, Deidda D, Denis-Bacelar AM, Fenwick A, Ferreira KM, Hamilton D, Heetun W, Julyan P, Needham G, Pietras B, Price E, Scuffham J, Tipping J, Robinson AP. Quantitative validation of Monte Carlo SPECT simulation: application to a Mediso AnyScan GATE simulation. EJNMMI Phys 2023;10:60. [PMID: 37777689 PMCID: PMC10542438 DOI: 10.1186/s40658-023-00581-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 09/15/2023] [Indexed: 10/02/2023]  Open
4
Schiebler T, Apostolova I, Mathies FL, Lange C, Klutmann S, Buchert R. No impact of attenuation and scatter correction on the interpretation of dopamine transporter SPECT in patients with clinically uncertain parkinsonian syndrome. Eur J Nucl Med Mol Imaging 2023;50:3302-3312. [PMID: 37328621 PMCID: PMC10541531 DOI: 10.1007/s00259-023-06293-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 06/05/2023] [Indexed: 06/18/2023]
5
Absolute Quantification in Diagnostic SPECT/CT: The Phantom Premise. Diagnostics (Basel) 2021;11:diagnostics11122333. [PMID: 34943570 PMCID: PMC8700635 DOI: 10.3390/diagnostics11122333] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 12/03/2021] [Accepted: 12/06/2021] [Indexed: 02/07/2023]  Open
6
Tran-Gia J, Denis-Bacelar AM, Ferreira KM, Robinson AP, Calvert N, Fenwick AJ, Finocchiaro D, Fioroni F, Grassi E, Heetun W, Jewitt SJ, Kotzassarlidou M, Ljungberg M, McGowan DR, Scott N, Scuffham J, Gleisner KS, Tipping J, Wevrett J, Lassmann M. A multicentre and multi-national evaluation of the accuracy of quantitative Lu-177 SPECT/CT imaging performed within the MRTDosimetry project. EJNMMI Phys 2021;8:55. [PMID: 34297218 PMCID: PMC8302709 DOI: 10.1186/s40658-021-00397-0] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Accepted: 06/21/2021] [Indexed: 11/10/2022]  Open
7
Lotter K, Diemling M, Sohlberg A, Wiedner H, Haug A, Maringer FJ. Comparing calculated and experimental activity and dose values obtained from image-based quantification of 90Y SPECT/CT Data. Z Med Phys 2021;31:378-387. [PMID: 33966943 DOI: 10.1016/j.zemedi.2021.03.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 01/13/2021] [Accepted: 03/29/2021] [Indexed: 11/19/2022]
8
Kangasmaa T, Hippeläinen E, Constable C, Turunen S, Sohlberg A. Quantitative Monte Carlo-based brain dopamine transporter SPECT imaging. Ann Nucl Med 2021;35:17-23. [PMID: 32978713 DOI: 10.1007/s12149-020-01532-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 09/16/2020] [Indexed: 10/23/2022]
9
Roberts G, Lloyd JJ, Petrides GS, O'Brien JT, Thomas AJ. Cardiac 123I-MIBG planar heart to mediastinum ratios depend on patient size; phantom studies suggest SPECT-CT could improve quantification. Biomed Phys Eng Express 2019;6:015011. [PMID: 33438599 DOI: 10.1088/2057-1976/ab5c09] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
10
Gregory RA, Murray I, Gear J, Leek F, Chittenden S, Fenwick A, Wevrett J, Scuffham J, Tipping J, Murby B, Jeans S, Stuffins M, Michopoulou S, Guy M, Morgan D, Hallam A, Hall D, Polydor H, Brown C, Gillen G, Dickson N, Brown S, Wadsley J, Flux G. Standardised quantitative radioiodine SPECT/CT Imaging for multicentre dosimetry trials in molecular radiotherapy. Phys Med Biol 2019;64:245013. [PMID: 31766032 DOI: 10.1088/1361-6560/ab5b6c] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
11
Evaluation of quantitative 123I and 131I SPECT with Monte Carlo-based down-scatter compensation. Nucl Med Commun 2018;39:1097-1102. [PMID: 30222722 DOI: 10.1097/mnm.0000000000000920] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
12
Porter CA, Bradley KM, Hippeläinen ET, Walker MD, McGowan DR. Phantom and clinical evaluation of the effect of full Monte Carlo collimator modelling in post-SIRT yttrium-90 Bremsstrahlung SPECT imaging. EJNMMI Res 2018;8:7. [PMID: 29356993 PMCID: PMC5778088 DOI: 10.1186/s13550-018-0361-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Accepted: 01/10/2018] [Indexed: 01/06/2023]  Open
13
Fast GPU-based Monte Carlo code for SPECT/CT reconstructions generates improved 177Lu images. EJNMMI Phys 2018;5:1. [PMID: 29302810 PMCID: PMC5754277 DOI: 10.1186/s40658-017-0201-8] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2017] [Accepted: 12/07/2017] [Indexed: 02/05/2023]  Open
14
Dosimetry software Hermes Internal Radiation Dosimetry: from quantitative image reconstruction to voxel-level absorbed dose distribution. Nucl Med Commun 2017;38:357-365. [PMID: 28338529 DOI: 10.1097/mnm.0000000000000662] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
15
Hippeläinen E, Tenhunen M, Sohlberg A. Fast voxel-level dosimetry for (177)Lu labelled peptide treatments. Phys Med Biol 2015;60:6685-700. [PMID: 26270032 DOI: 10.1088/0031-9155/60/17/6685] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
16
Optimisation of simultaneous tl-201/tc-99m dual isotope reconstruction with monte-carlo-based scatter correction. INTERNATIONAL JOURNAL OF MOLECULAR IMAGING 2012;2012:695632. [PMID: 23213515 PMCID: PMC3506904 DOI: 10.1155/2012/695632] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/10/2012] [Revised: 10/09/2012] [Accepted: 10/23/2012] [Indexed: 11/17/2022]
17
Momennezhad M, Sadeghi R, Nasseri S. Development of GATE Monte Carlo simulation for a dual-head gamma camera. Radiol Phys Technol 2012;5:222-8. [PMID: 22588590 DOI: 10.1007/s12194-012-0157-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2011] [Revised: 04/21/2012] [Accepted: 04/25/2012] [Indexed: 11/25/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA