Akgun E, Ibrahimli A, Rahman M, Griffith C, Berber E. Correlation Between Near-Infrared Autofluorescence Properties and Sestamibi Uptakes of Parathyroid Glands in Primary Hyperparathyroidism.
Otolaryngol Head Neck Surg 2024;
171:1341-1348. [PMID:
39154258 DOI:
10.1002/ohn.948]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Revised: 07/29/2024] [Accepted: 08/03/2024] [Indexed: 08/19/2024]
Abstract
OBJECTIVE
Near-infrared autofluorescence (NIRAF) characteristics of parathyroid glands in primary hyperparathyroidism (pHPT) vary, with unclarity regarding the underlying mechanism. Similarly, 99mTc-sestamibi uptake in diseased parathyroid glands is variable. There is a suggestion that oxyphilic cell content may influence both imaging modalities. This study aims to analyze the relationship between NIRAF imaging characteristics, 99mTc-sestamibi uptake, and cellular composition in pHPT.
STUDY DESIGN
Retrospective analysis of an Institutional Review Board-monitored prospective database.
SETTING
Single tertiary referral center.
METHODS
NIRAF characteristics of parathyroid glands of patients with pHPT between 2019 and 2024 were compared with 99mTc-sestamibi scan findings from a prospective database. Using third-party software, brightness intensity and heterogeneity index (HI) of the glands were calculated. A subgroup of parathyroid glands obtained from consecutive patients with pHPT in 2020 to 2021 underwent histological analysis.
RESULTS
A total of 428 patients with 638 diseased parathyroid glands were analyzed. Forty-seven percent of the glands showed an uptake on 99mTc-sestamibi scans. The brightness intensity of the NIRAF signals from parathyroid glands that were seen versus not seen on sestamibi was 2.1 versus 2.3 (P = .002) and HI 0.18 versus 0.17 (P = .35), respectively. On multivariate analysis, low autofluorescence intensity, high gland volume, and single adenoma were associated with detectability on 99mTc-sestamibi scan (P < .0001). Intraglandular adipose tissue content was lower in diseased glands that were detected on 99mTc-sestamibi scans (0% vs 5%, P < .0001).
CONCLUSION
Our findings indicate an inverse relationship between autofluorescence intensity and detectability on 99mTc-sestamibi scans and a lack of correlation between different cell types and autofluorescence properties.
Collapse