1
|
Ullah N, Tuzen M, Saleh TA. A comprehensive review of portable syringe systems using micropipette-based extraction techniques for metal analysis. J Chromatogr A 2024; 1736:465423. [PMID: 39413567 DOI: 10.1016/j.chroma.2024.465423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2024] [Revised: 10/04/2024] [Accepted: 10/05/2024] [Indexed: 10/18/2024]
Abstract
The release of harmful compounds, particularly dangerous metal ions, into the environment has drawn deep concern from the scientific community. Therefore, it has become common in research to evaluate and quantify the harmful concentrations in the presence of these metal ions in several real samples (food, water, and biological samples). To increase sensitivity and lessen the impact of the matrix, sample pretreatment is a helpful strategy to implement before analysis. The limitations of conventional methods have been recently significantly reduced by developing new analytical approaches such as microextraction techniques. The miniaturization of conventional solid-phase extraction (SPE) led to solid-phase microextraction (SPME), drastically reducing both adsorbent use and extraction phase volume. SPME is defined in the present context as a modified extraction technique that employs a portable syringe system attached to micropipette tips. The SPME is considered one of the most appropriate sample preparation tools due to its compatibility with different detection techniques for different metal ions. The current review focuses on SPME based on a portable syringe (attaches to a micropipette tip) system because it has many advantages over conventional solid-phase extraction. It can be designed very simply in a syringe system, a very small quantity of the sorbent has to be kept in the tip, tube, or inside a syringe as a plug and combined with various analytical instruments. Many researchers have designed their own by using homemade tips packed with a sorbent to increase extraction capability and selectivity. According to the current review, there is a lot of potential for increasing the efficacy and efficiency of metal ion extraction from complicated matrices using portable syringe SPME. Studies have shown that when compared to conventional approaches, it performs better in terms of sensitivity, selectivity, and user-friendliness. Furthermore, its application to a wider range of sample types has been enhanced by the flexibility in constructing unique sorbent tips. Conclusively, the developments in portable syringe SPME have addressed several limitations of conventional techniques, positioning it as a robust and versatile tool for environmental monitoring and analysis of hazardous metal ions.
Collapse
Affiliation(s)
- Naeem Ullah
- Tokat Gaziosmanpaşa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey; Department of Chemistry, University of Turbat, Balochistan 92600, Pakistan
| | - Mustafa Tuzen
- Tokat Gaziosmanpaşa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
| | - Tawfik A Saleh
- Department of Chemistry, King Fahd University of Petroleum and Minerals, Dhahran, 31261, Saudi Arabia.
| |
Collapse
|
2
|
Woźniak J, Nawała J, Dziedzic D, Popiel S. Overview of Liquid Sample Preparation Techniques for Analysis, Using Metal-Organic Frameworks as Sorbents. Molecules 2024; 29:4752. [PMID: 39407677 PMCID: PMC11477957 DOI: 10.3390/molecules29194752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2024] [Revised: 09/24/2024] [Accepted: 09/25/2024] [Indexed: 10/20/2024] Open
Abstract
The preparation of samples for instrumental analysis is the most essential and time-consuming stage of the entire analytical process; it also has the greatest impact on the analysis results. Concentrating the sample, changing its matrix, and removing interferents are often necessary. Techniques for preparing samples for analysis are constantly being developed and modified to meet new challenges, facilitate work, and enable the determination of analytes in the most comprehensive concentration range possible. This paper focuses on using metal-organic frameworks (MOFs) as sorbents in the most popular techniques for preparing liquid samples for analysis, based on liquid-solid extraction. An increase in interest in MOFs-type materials has been observed for about 20 years, mainly due to their sorption properties, resulting, among others, from the high specific surface area, tunable pore size, and the theoretically wide possibility of their modification. This paper presents certain advantages and disadvantages of the most popular sample preparation techniques based on liquid-solid extraction, the newest trends in the application of MOFs as sorbents in those techniques, and, most importantly, presents the reader with a summary, which a specific technique and MOF for the desired application. To make a tailor-made and well-informed choice as to the extraction technique.
Collapse
Affiliation(s)
| | | | | | - Stanisław Popiel
- Faculty of Advanced Technologies and Chemistry, Institute of Chemistry, Military University of Technology, Kaliskiego Str. 2, 00-908 Warsaw, Poland; (J.W.); (J.N.); (D.D.)
| |
Collapse
|
3
|
A novel modified magnetic Co-MOF-71 for magnetic solid phase extraction of Hg(II) ions in food samples. RESEARCH ON CHEMICAL INTERMEDIATES 2023. [DOI: 10.1007/s11164-023-04976-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
|
4
|
Sun M, Sun H, Feng J, Feng J, Fan J, Sun M, Feng Y. Carbonized metal-organic framework-74/carbon aerogel composites for the efficient extraction of triazole fungicides from fruits and vegetables. J Chromatogr A 2022; 1683:463552. [DOI: 10.1016/j.chroma.2022.463552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 09/30/2022] [Accepted: 10/02/2022] [Indexed: 10/31/2022]
|
5
|
Ullah N, Tuzen M. A New Trend and Future Perspectives of the Miniaturization of Conventional Extraction Methods for Elemental Analysis in Different Real Samples: A Review. Crit Rev Anal Chem 2022; 54:1729-1747. [PMID: 36197714 DOI: 10.1080/10408347.2022.2128635] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/10/2022]
Abstract
Sample preparation is one of the viable procedures to be used before analysis to enhance sensitivity and reduce the matrix effect. The current review is mainly emphasized the latest outcome and applications of microextraction techniques based on the miniaturization of the classical conventional methods based on liquid-phase and solid-phase extraction for the quantitative elemental analysis in different real samples. The limitation of the conventional sample preparation methods (liquid and solid phase extraction) has been overcome by developing a new way of reducing size as compared with the conventional system through the miniaturization approach. Miniaturization of the sample preparation techniques has received extensive attention due to its extraction at microlevels, speedy, economical, eco-friendly, and high extraction capability. The growing demand for speedy, economically feasible, and environmentally sound analytical approaches is the main intention to upgrade the conventional procedures apply for sample preparation in environmental investigation. A growing trend of research has been perceived to quantify the trace for elemental analysis in different natures of real samples. This review also recapitulates the current futuristic scenarios for the green and economically viable procedure with special overemphasis and concentrates on eco-friendly miniaturized sample-preparation techniques such as liquid-phase microextraction (LPME) and solid-phase microextraction (SPME). This review also emphasizes the latest progress and applications of the LPME and SPME approach and their future perspective.
Collapse
Affiliation(s)
- Naeem Ullah
- Faculty of Science and Arts, Chemistry Department, Tokat Gaziosmanpaşa University, Tokat, Turkey
- Department of Chemistry, University of Turbat, Balochistan, Pakistan
| | - Mustafa Tuzen
- Faculty of Science and Arts, Chemistry Department, Tokat Gaziosmanpaşa University, Tokat, Turkey
- Research Institute, Center for Environment and Marine Studies, King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
| |
Collapse
|
6
|
Jinadasa KK, Peña-Vázquez E, Bermejo-Barrera P, Moreda-Piñeiro A. Smart materials for mercury and arsenic determination in food and beverages. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107472] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
7
|
Yao Z, Liu J, Mao X, Chen G, Ma Z, Li B. Ultratrace mercury speciation analysis in rice by in-line solid phase extraction - liquid chromatography - atomic fluorescence spectrometry. Food Chem 2022; 379:132116. [PMID: 35063845 DOI: 10.1016/j.foodchem.2022.132116] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 12/13/2021] [Accepted: 01/07/2022] [Indexed: 11/04/2022]
Abstract
For the first time, Hg2+ and methylmercury speciation analysis was accomplished by in-line SPE-LC-AFS. After modification with 0.1 mL of 0.001% (m:v) sodium diethyldithiocarbamate, a C18 microcolumn retained Hg2+ and MetHg in rice extract within 3 min; the captured Hg species were separated within 12 min in 0.25% (v:v) 2-mercaptoethanol + 60 mmol L-1 (m:v) ammonium acetate + 4% (v:v) acetonitrile. Under optimized conditions, the detection limits were 0.3 ng L-1 for Hg2+ and 0.2 ng L-1 for MetHg, respectively, with 10 mL injection vs. 0.1 mL eluent; in-line SPE achieved ∼ 100x enrichment. Method precision and accuracy were satisfactory at < 2% relative standard deviations (RSDs) for 20 ng L-1 of Hg2+ and MetHg and 95-102% recoveries for real rice samples. In-line SPE obviated human involvement and avoided invalid transportation between interfaces, rendering this SPE-LC-AFS method easy, compact, robust, yet sensitive in mercury speciation analysis to uphold food safety.
Collapse
Affiliation(s)
- Zhenzhen Yao
- Institute of Quality Standard and Testing Technology for Agro-products, Chinese Academy of Agricultural Sciences, and Key Laboratory of Agro-food Safety and Quality, Ministry of Agriculture and Rural Affairs, Beijing 100081, China; Institute of Quality Standard and Testing Technology, BAAFS (Beijing Academy of Agriculture and Forestry Sciences), Beijing 100097, China
| | - Jixin Liu
- Institute of Quality Standard and Testing Technology for Agro-products, Chinese Academy of Agricultural Sciences, and Key Laboratory of Agro-food Safety and Quality, Ministry of Agriculture and Rural Affairs, Beijing 100081, China; Beijing Ability Technology Company, Limited, Beijing 100081, China.
| | - Xuefei Mao
- Institute of Quality Standard and Testing Technology for Agro-products, Chinese Academy of Agricultural Sciences, and Key Laboratory of Agro-food Safety and Quality, Ministry of Agriculture and Rural Affairs, Beijing 100081, China.
| | - Guoying Chen
- U.S. Department of Agriculture, Agricultural Research Service, Eastern Regional Research Center, 600 E. Mermaid Lane, Wyndmoor, PA 19038, USA
| | - Zhihong Ma
- Institute of Quality Standard and Testing Technology, BAAFS (Beijing Academy of Agriculture and Forestry Sciences), Beijing 100097, China
| | - Bingru Li
- Institute of Quality Standard and Testing Technology, BAAFS (Beijing Academy of Agriculture and Forestry Sciences), Beijing 100097, China
| |
Collapse
|
8
|
Feng S, Zhang A, Wu F, Luo X, Zhang J. Boronic acid grafted metal-organic framework for selective enrichment of cis-diol-containing compounds. J Chromatogr A 2022; 1677:463281. [DOI: 10.1016/j.chroma.2022.463281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 06/22/2022] [Accepted: 06/24/2022] [Indexed: 10/17/2022]
|
9
|
Pinar Gumus Z, Soylak M. Metal organic frameworks as nanomaterials for analysis of toxic metals in food and environmental applications. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116417] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
10
|
Ragheb E, Shamsipur M, Jalali F, Sadeghi M, Babajani N, Mafakheri N. Magnetic solid-phase extraction using metal–organic framework-based biosorbent followed by ligandless deep-eutectic solvent-ultrasounds-assisted dispersive liquid–liquid microextraction (DES-USA-DLLME) for preconcentration of mercury (II). Microchem J 2021. [DOI: 10.1016/j.microc.2021.106209] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
11
|
Sun H, Feng J, Han S, Ji X, Li C, Feng J, Sun M. Recent advances in micro- and nanomaterial-based adsorbents for pipette-tip solid-phase extraction. Mikrochim Acta 2021; 188:189. [PMID: 33991231 DOI: 10.1007/s00604-021-04806-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Accepted: 03/21/2021] [Indexed: 11/30/2022]
Abstract
There are a lot of review papers of sample pretreatment, but the comprehensive review on pipette-tip solid-phase extraction (PT-SPE) is lacking. This review (133 references) is mainly devoted to the development of different types of micro- and nanosorbent-based PT-SPE, including silica materials, carbon materials, organic polymers, molecularly imprinted polymers, and metal-organic frameworks. Each section mainly introduces and discusses the preparation methods, advantages and limitations of adsorbents, and their applications to environmental, biological, and food samples. This review also demonstrates the advantages of PT-SPE like convenience, speed, less organic solvent, and low cost. Finally, the future application and development trend of PT-SPE are prospected.
Collapse
Affiliation(s)
- Haili Sun
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, People's Republic of China
| | - Juanjuan Feng
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, People's Republic of China
| | - Sen Han
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, People's Republic of China
| | - Xiangping Ji
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, People's Republic of China
| | - Chunying Li
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, People's Republic of China
| | - Jiaqing Feng
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, People's Republic of China
| | - Min Sun
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, People's Republic of China.
| |
Collapse
|
12
|
Abstract
Metal Organic Frameworks (MOFs) are noted as exceptional candidates towards the detection and removal of specific analytes. MOFs were reported in particular for the detection/removal of environmental contaminants, such as heavy metal ions, toxic anions, hazardous gases, explosives, etc. Among heavy metal ions, mercury has been noted as a global hazard because of its high toxicity in the elemental (Hg0), divalent cationic (Hg2+), and methyl mercury (CH3Hg+) forms. To secure the environment and living organisms, many countries have imposed stringent regulations to monitor mercury at all costs. Regarding the detection/removal requirements of mercury, researchers have proposed and reported all kinds of MOFs-based luminescent/non-luminescent probes towards mercury. This review provides valuable information about the MOFs which have been engaged in detection and removal of elemental mercury and Hg2+ ions. Moreover, the involved mechanisms or adsorption isotherms related to sensors or removal studies are clarified for the readers. Finally, advantages and limitations of MOFs in mercury detection/removal are described together with future scopes.
Collapse
|
13
|
Ali MM, Zhu Z, Wang M, Hussain D, Gao X, Wang J, Du Z. Melamine foam assisted in-tip packed amine-functionalized titanium metal-organic framework for the selective enrichment of endogenous glycopeptides. J Chromatogr A 2020; 1636:461711. [PMID: 33316563 DOI: 10.1016/j.chroma.2020.461711] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 11/04/2020] [Accepted: 11/09/2020] [Indexed: 12/16/2022]
Abstract
Endogenous glycopeptides are significantly important in diverse pathological and physiological systems, but their direct analysis is severely hampered by their low abundance and presence of interfering species in biological fluids. In this study, we synthesized the amine-functionalized titanium metal-organic framework (NH2-MIL-125(Ti)) by a simple hydrothermal method, characterized and used for glycopeptides enrichment. The designed separation media is highly hydrophilic and stable which is suitable for hydrophilic interaction chromatography (HILIC). To make the process smooth, simple, reliable, and robust, NH2-MIL-125(Ti) crystals were packed in pipette-tip using hydrophilic melamine foam, as supporting frit. Free amine groups, present in the structure imparted hydrophilicity and a unique pattern of porosity, contributing to the size exclusion effect that excluded the large-sized proteins up to 1:700 peptide to protein ratio. The prepared MOF particles possessed regular porosity, high surface area, good hydrophilicity, and offered an in-tip flow-based set-up enhanced the enrichment performance for N-linked glycopeptides. The affinity material showed a detection limit of 1 fmol.µL-1 and selectivity up to 1:1000 (HRP digest to BSA digest). Moreover, repeatability and reusability were evaluated up to five rounds of enrichment using the same affinity tip, and scanning electron microscopic images revealed no structural changes in the MOF crystals. Finally, the MOF packed in pipette tip was applied to selectively capture the N-linked endogenous glycopeptides from a healthy saliva sample and 64 unique endogenous glycopeptides were identified. These results demonstrated the excellent potential of NH2-MIL-125(Ti) based affinity tip for glycopeptides which can be used to enrich trace glycopeptide biomarkers from the biological fluids.
Collapse
Affiliation(s)
- Muhammad Mujahid Ali
- College of Chemistry, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Zhiyuan Zhu
- College of Chemistry, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Mengyu Wang
- College of Chemistry, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Dilshad Hussain
- HEJ Research Institute of Chemistry, International Center for Chemical and Biological Sciences, University of Karachi, Karachi 75270, Pakistan
| | - Xia Gao
- Beijing Center for Physical and Chemical Analysis, Beijing Engineering Research Center of Food Safety Analysis, Beijing 100089, China
| | - Jianfeng Wang
- College of Chemistry, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Zhenxia Du
- College of Chemistry, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, 100029, China.
| |
Collapse
|
14
|
Zhang H, Xiong P, Li G, Liao C, Jiang G. Applications of multifunctional zirconium-based metal-organic frameworks in analytical chemistry: Overview and perspectives. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.116015] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
15
|
Determination of the Total Content of Arsenic, Antimony, Selenium and Mercury in Chinese Herbal Food by Chemical Vapor Generation-Four-Channel Non-dispersive Atomic Fluorescence Spectrometry. J Fluoresc 2020; 30:949-954. [PMID: 32548704 DOI: 10.1007/s10895-020-02569-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Accepted: 06/03/2020] [Indexed: 12/16/2022]
Abstract
Food security is related to safe and nutritious food which meets people's dietary needs and food preferences for an active and healthy life. A simple and feasible method was proposed for the simultaneous analysis of trace arsenic (As), antimony (Sb), selenium (Se) and mercury (Hg) in Chinese herbal food by chemical vapor generation coupled non-dispersive atomic fluorescence spectrometry (CVG-NDAFS) in this paper. The operating parameters, such as observation height, carrier and shield gas flow rate, were optimized. The detection limits were obtained under optimal conditions, which were 0.051, 0.034, 0.050 and 0.0058 ng mL-1, respectively for As, Sb, Se and Hg. The relative standard deviations were 0.42%, 0.74%, 0.97% and 1.0% (n = 7), respectively (10 ng mL-1of As, Sb, Se and 1 ng ml-1of Hg). The proposed method is verified to simultaneously determine As, Sb, Se and Hg for Chinese herbal food.
Collapse
|
16
|
Khajeh M, Oveisi AR, Barkhordar A, Sorinezami Z. Co-Fe-layered double hydroxide decorated amino-functionalized zirconium terephthalate metal-organic framework for removal of organic dyes from water samples. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 234:118270. [PMID: 32203685 DOI: 10.1016/j.saa.2020.118270] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 03/09/2020] [Accepted: 03/15/2020] [Indexed: 06/10/2023]
Abstract
In this study, a new efficient adsorbent of Co-Fe-layered double hydroxides@metal-organic framework (Co-Fe-LDH@UiO-66-NH2) was synthesized and used for extraction of methylene blue (MB) and methylene red (MR) from water samples prior to their determination by UV-Vis spectrophotometer. The adsorbent was characterized by Fourier Transform Infrared Spectroscopy (FT-IR), Scanning Electron Microscopy (SEM), Energy Dispersive X-Ray (EDX), X-ray Diffraction (XRD), and Brunauer-Emmett-Teller (BET) analyses. The impact of various parameters such as pH of the aqueous phase, extraction time, amount of adsorbent, type and volume of eluent solvent, desorption time, and sample volume were studied. The maximum extraction recovery was obtained at an optimized pH 8.0 and extraction time 10.0 min. The adsorption process was fitted by the Langmuir model with a maximum adsorption capacity of 555.62 mg/g and 588.2 mg/g, respectively, for MB and MR. Under optimum conditions, the limit of detection (LOD) for MB was 0.7 μgL-1 and 0.9 μgL-1 for MR. Furthermore, the Co-Fe-LDH@UiO-66-NH2 composite showed high efficiency for the removal of the analytes from environmental water samples.
Collapse
Affiliation(s)
- Mostafa Khajeh
- Department of Chemistry, Faculty of Science, University of Zabol, Zabol, P. O. Box 98615-538, Iran.
| | - Ali Reza Oveisi
- Department of Chemistry, Faculty of Science, University of Zabol, Zabol, P. O. Box 98615-538, Iran
| | - Afsaneh Barkhordar
- Department of Chemistry, Faculty of Science, University of Zabol, Zabol, P. O. Box 98615-538, Iran
| | - Ziba Sorinezami
- Department of Chemistry, Faculty of Science, University of Zabol, Zabol, P. O. Box 98615-538, Iran
| |
Collapse
|
17
|
Tabatabaii M, Khajeh M, Oveisi AR, Erkartal M, Sen U. Poly(lauryl methacrylate)-Grafted Amino-Functionalized Zirconium-Terephthalate Metal-Organic Framework: Efficient Adsorbent for Extraction of Polycyclic Aromatic Hydrocarbons from Water Samples. ACS OMEGA 2020; 5:12202-12209. [PMID: 32548403 PMCID: PMC7271357 DOI: 10.1021/acsomega.0c00687] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/15/2020] [Accepted: 04/23/2020] [Indexed: 06/11/2023]
Abstract
In this study, a novel porous hybrid material, poly(lauryl methacrylate) polymer-grafted UiO-66-NH2 (UiO = University of Oslo), was synthesized for efficient extraction of polycyclic aromatic hydrocarbons (PAHs) from aqueous samples. The polymer end-tethered covalently to the MOF's surface was synthesized by surface-initiated atom transfer radical polymerization, revealing a distinct type of morphology. The adsorbent was characterized by scanning electron microscopy, energy-dispersive spectroscopy, transmission electron microscopy, powder X-ray diffraction, N2 adsorption-desorption analysis, Fourier transform infrared spectroscopy, and thermogravimetric analysis. The analyses were carried out by gas chromatography-mass spectrometry. Parameters including the type and volume of the eluent, the amount of the adsorbent, and adsorption and desorption times were investigated and optimized. Under optimal conditions, the limit of detection, intraday precision, and interday precision were in the range of 3-8 ng L-1, 1.4-3.1, and 4.1-6.5%, respectively. The procedure was used for analysis of PAHs from natural water samples.
Collapse
Affiliation(s)
- Maryam Tabatabaii
- Department
of Chemistry, Faculty of Science, University
of Zabol, P.O. Box: 98615-538 Zabol, Iran
| | - Mostafa Khajeh
- Department
of Chemistry, Faculty of Science, University
of Zabol, P.O. Box: 98615-538 Zabol, Iran
| | - Ali Reza Oveisi
- Department
of Chemistry, Faculty of Science, University
of Zabol, P.O. Box: 98615-538 Zabol, Iran
| | - Mustafa Erkartal
- Department
of Materials Science and Nanotechnology Engineering, Abdullah Gul University, 38080 Kayseri, Turkey
| | - Unal Sen
- Department
of Materials Science and Engineering, Faculty of Engineering, Eskisehir Technical University, 26555 Eskisehir, Turkey
| |
Collapse
|
18
|
Manousi N, Rosenberg E, Deliyanni EA, Zachariadis GA. Sample Preparation Using Graphene-Oxide-Derived Nanomaterials for the Extraction of Metals. Molecules 2020; 25:E2411. [PMID: 32455827 PMCID: PMC7287798 DOI: 10.3390/molecules25102411] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Revised: 05/14/2020] [Accepted: 05/17/2020] [Indexed: 11/16/2022] Open
Abstract
Graphene oxide is a compound with a form similar to graphene, composed of carbon atoms in a sp2 single-atom layer of a hybrid connection. Due to its significant surface area and its good mechanical and thermal stability, graphene oxide has a plethora of applications in various scientific fields including heterogenous catalysis, gas storage, environmental remediation, etc. In analytical chemistry, graphene oxide has been successfully employed for the extraction and preconcentration of organic compounds, metal ions, and proteins. Since graphene oxide sheets are negatively charged in aqueous solutions, the material and its derivatives are ideal sorbents to bind with metal ions. To date, various graphene oxide nanocomposites have been successfully synthesized and evaluated for the extraction and preconcentration of metal ions from biological, environmental, agricultural, and food samples. In this review article, we aim to discuss the application of graphene oxide and functionalized graphene oxide nanocomposites for the extraction of metal ions prior to their determination via an instrumental analytical technique. Applications of ionic liquids and deep eutectic solvents for the modification of graphene oxide and its functionalized derivatives are also discussed.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Erwin Rosenberg
- Institute of Chemical Technology and Analytics, Vienna University of Technology, 1060 Vienna, Austria;
| | - Eleni A. Deliyanni
- Laboratory of Chemical and Environmental Technology, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece;
| | - George A. Zachariadis
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| |
Collapse
|
19
|
Safaei Moghaddam Z, Kaykhaii M, Khajeh M, Oveisi AR. PCN-222 metal-organic framework: a selective and highly efficient sorbent for the extraction of aspartame from gum, juice, and diet soft drink before its spectrophotometric determination. BMC Chem 2020; 14:19. [PMID: 32206761 PMCID: PMC7085135 DOI: 10.1186/s13065-020-00674-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Accepted: 03/12/2020] [Indexed: 11/10/2022] Open
Abstract
In this paper, we describe synthesis and application of an iron porphyrinc metal-organic framework PCN-222(Fe) for solid phase extraction of aspartame, an artificial non-saccharine sweetener, from gum, juice and diet soft drink samples prior to its determination by spectrophotometry. The mesoporous MOF was synthesized solvo-thermally and characterized by Fourier transform-infrared spectroscopy, powder X-ray diffraction, scanning electron microscopy, and Brunauer-Emmett-Teller techniques. To obtain the best extraction efficiency of aspartame, significant affecting parameters such as pH of sample solution, amount of the sorbent, type and volume of eluting solvent, and adsorption and desorption times were investigated and optimized. Under optimum conditions, the calibration graph for aspartame was linear in the range of 0.1 to 100.0 mg.L-1 and relative standard deviation of aspartame was 1.7% (n = 7). Limit of detection of method calculated as 0.019 mg.L-1 and the enrichment factor of 350 folds was obtained. Adsorption capacity of synthesized sorbent was found to be 356 mg.g-1. Hierarchical porosity, the eight terminal-OH groups of the Zr6 node, and hydrogen bonding possibly play vital role for selective adsorption of aspartame. The optimized method was successfully applied to the determination of aspartame in real samples with reasonable recoveries (> 98%).
Collapse
Affiliation(s)
- Zahra Safaei Moghaddam
- 1Department of Chemistry, Faculty of Sciences, University of Sistan and Baluchestan, Zahedan, 98135-674 Iran
| | - Massoud Kaykhaii
- 1Department of Chemistry, Faculty of Sciences, University of Sistan and Baluchestan, Zahedan, 98135-674 Iran
| | - Mostafa Khajeh
- 2Department of Chemistry, Faculty of Science, University of Zabol, Zabol, Iran
| | - Ali Reza Oveisi
- 2Department of Chemistry, Faculty of Science, University of Zabol, Zabol, Iran
| |
Collapse
|
20
|
Vardali SC, Manousi N, Barczak M, Giannakoudakis DA. Novel Approaches Utilizing Metal-Organic Framework Composites for the Extraction of Organic Compounds and Metal Traces from Fish and Seafood. Molecules 2020; 25:E513. [PMID: 31991663 PMCID: PMC7036755 DOI: 10.3390/molecules25030513] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2020] [Revised: 01/20/2020] [Accepted: 01/21/2020] [Indexed: 01/19/2023] Open
Abstract
The determination of organic and inorganic pollutants in fish samples is a complex and demanding process, due to their high protein and fat content. Various novel sorbents including graphene, graphene oxide, molecular imprinted polymers, carbon nanotubes and metal-organic frameworks (MOFs) have been reported for the extraction and preconcentration of a wide range of contaminants from fish tissue. MOFs are crystalline porous materials that are composed of metal ions or clusters coordinated with organic linkers. Those materials exhibit extraordinary properties including high surface area, tunable pore size as well as good thermal and chemical stability. Therefore, metal-organic frameworks have been recently used in many fields of analytical chemistry including sample pretreatment, fabrication of stationary phases and chiral separations. Various MOFs, and especially their composites or hybrids, have been successfully utilized for the sample preparation of fish samples for the determination of organic (i.e., antibiotics, antimicrobial compounds, polycyclic aromatic hydrocarbons, etc.) and inorganic pollutants (i.e., mercury, palladium, cadmium, lead, etc.) as such or after functionalization with organic compounds.
Collapse
Affiliation(s)
- Sofia C. Vardali
- Institute of Biological Marine Resources, Hellenic Center of Marine Research, Agios Kosmas, Hellenikon, 16777 Athens, Greece
| | - Natalia Manousi
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Mariusz Barczak
- Department of Theoretical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University in Lublin, 20-031 Lublin, Poland;
| | | |
Collapse
|
21
|
Yuan Y, Nie H, Yin J, Han Y, Lv Y, Yan H. Selective extraction and detection of β-agonists in swine urine for monitoring illegal use in livestock breeding. Food Chem 2020; 313:126155. [PMID: 31945701 DOI: 10.1016/j.foodchem.2019.126155] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2019] [Revised: 12/28/2019] [Accepted: 12/31/2019] [Indexed: 01/02/2023]
Abstract
The illegal use of β-agonists often endangers animal-derived food safety. In this study, a selective detection method for β-agonists in swine urine was established via the combination of polymeric ionic liquid-molecularly imprinted graphene oxide-miniaturized pipette tip solid-phase extraction and high-performance liquid chromatography. It is worth noting that this method relied mainly on the designed adsorbent, which presented a rich adsorption mechanism, fast mass transfer rate, and high selectivity, and was successfully utilized in the selective extraction of β-agonists from swine urine samples. The proposed method has low LOD (0.20-0.56 ng/mL), high recovery (94.9-107.9%), and high reusability (4 times, 91.9-108.8%), which indicates its high potential as a selective, sensitive, accurate, and nonfatal method for monitoring the illegal use of β-agonists in the livestock breeding stage.
Collapse
Affiliation(s)
- Yanan Yuan
- Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, College of Chemistry and Environmental Science, Hebei University, Baoding 071002, China
| | - Hailiang Nie
- Key Laboratory of Analytical Science and Technology of Hebei Province, College of Public Health, Hebei University, Baoding 071002, China
| | - Junfa Yin
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Yehong Han
- Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, College of Chemistry and Environmental Science, Hebei University, Baoding 071002, China
| | - Yunkai Lv
- Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, College of Chemistry and Environmental Science, Hebei University, Baoding 071002, China
| | - Hongyuan Yan
- Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, College of Chemistry and Environmental Science, Hebei University, Baoding 071002, China; Key Laboratory of Analytical Science and Technology of Hebei Province, College of Public Health, Hebei University, Baoding 071002, China.
| |
Collapse
|
22
|
Kaykhaii M, Yavari E, Sargazi G, Ebrahimi AK. Highly Sensitive Determination of Bisphenol A in Bottled Water Samples by HPLC after Its Extraction by a Novel Th-MOF Pipette-Tip Micro-SPE. J Chromatogr Sci 2019; 58:373-382. [DOI: 10.1093/chromsci/bmz111] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2019] [Revised: 09/30/2019] [Accepted: 10/31/2019] [Indexed: 11/14/2022]
Abstract
Abstract
In this study, a novel thorium metal organic framework was synthesized, characterized and used as a sorbent for very efficient pipette tip micro solid-phase extraction of bisphenol A in bottled drinking water samples using high-performance liquid chromatography as detecting instrument. Parameters which influence extraction efficiency such as pH, sample volume, amount of sorbent, type and volume of eluent, number of aspirating and dispensing cycles for extraction and elution, and volume of the sample solution were studied and optimized. A linear calibration curve was obtained in the range of 0.002–0.456 ng mL−1 (r2 = 0.996) with a detection limit of 0.0010 ng mL−1. Repeatability of batch-to-batch extraction was better than 5.0% and a reproducibility of 3.2% for real samples obtained.
Collapse
Affiliation(s)
- Massoud Kaykhaii
- Department of Chemistry, Faculty of Sciences, University of Sistan and Baluchestan, University Boulevard, Zahedan 98155-674, Iran
| | - Eilnaz Yavari
- Department of Chemistry, Faculty of Sciences, University of Sistan and Baluchestan, University Boulevard, Zahedan 98155-674, Iran
| | - Ghasem Sargazi
- Department of Nanotechnology, Graduate University of Advanced Technology, Kerman, Iran
| | | |
Collapse
|
23
|
Manousi N, Giannakoudakis DA, Rosenberg E, Zachariadis GA. Extraction of Metal Ions with Metal-Organic Frameworks. Molecules 2019; 24:E4605. [PMID: 31888229 PMCID: PMC6943743 DOI: 10.3390/molecules24244605] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Revised: 12/09/2019] [Accepted: 12/13/2019] [Indexed: 12/12/2022] Open
Abstract
Metal-organic frameworks (MOFs) are crystalline porous materials composed of metal ions or clusters coordinated with organic linkers. Due to their extraordinary properties such as high porosity with homogeneous and tunable in size pores/cages, as well as high thermal and chemical stability, MOFs have gained attention in diverse analytical applications. MOFs have been coupled with a wide variety of extraction techniques including solid-phase extraction (SPE), dispersive solid-phase extraction (d-SPE), and magnetic solid-phase extraction (MSPE) for the extraction and preconcentration of metal ions from complex matrices. The low concentration levels of metal ions in real samples including food samples, environmental samples, and biological samples, as well as the increased number of potentially interfering ions, make the determination of trace levels of metal ions still challenging. A wide variety of MOF materials have been employed for the extraction of metals from sample matrices prior to their determination with spectrometric techniques.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | | | - Erwin Rosenberg
- Institute of Chemical Technology and Analytics, Vienna University of Technology, 1060 Vienna, Austria;
| | - George A. Zachariadis
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| |
Collapse
|
24
|
Metal organic framework assisted in situ complexation for miniaturized solid phase extraction of organic mercury in fish and Dendrobium officinale. Talanta 2019; 209:120598. [PMID: 31892039 DOI: 10.1016/j.talanta.2019.120598] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Revised: 11/20/2019] [Accepted: 11/25/2019] [Indexed: 11/22/2022]
Abstract
Zirconium-based metal-organic frameworks, namely Zr-based MOF, was employed as adsorbent material in the miniaturized solid phase extraction of organic mercury compounds in food prior to capillary electrophoresis-diode array detector analysis. The synthesized adsorbent was characterized by different spectroscopic techniques. Parameters influencing the extraction and complexation of methylmercury chloride, ethylmercury chloride and phenylmercury chloride such as type of eluent solvent, type and amount of adsorbent were investigated. In addition, linear ranges contained 2.00-300.00 ng mL-1 for MeHg+, 5.00-500.00 ng mL-1 for EtHg+ and PhHg+, and the established method presented good linearity (R2 ≥ 0.998). Under the optimized experimental conditions, the ranges of detection limit and quantitation limit were 0.022-0.067 ng mL-1 and 0.073-0.220 ng mL-1, respectively. The relative standard deviations of intra- and inter-day analysis were less than 3.2 and 3.1%, respectively. Trueness of the present method was successfully accomplished by means of the recovery assays (81.4-98.5%) in the blank samples with two concentration levels. The repeatability %RSD of the method was lower than 2.7%. Overall, the developed approach proved to have the latent capability to be utilized in routine analysis of organic mercury compounds in fish and Dendrobium officinale.
Collapse
|
25
|
Ehzari H, Safari M, Shahlaei M. A signal amplification by QDs used for ferrocene-labeled sandwich aptasensor for determination of Hg2+ in water samples. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2019. [DOI: 10.1007/s13738-019-01718-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
26
|
Abstract
Metal-organic frameworks (MOFs) are porous hybrid materials composed of metal ions and organic linkers, characterized by their crystallinity and by the highest known surface areas. MOFs structures present accessible cages, tunnels and modifiable pores, together with adequate mechanical and thermal stability. Their outstanding properties have led to their recognition as revolutionary materials in recent years. Analytical chemistry has also benefited from the potential of MOF applications. MOFs succeed as sorbent materials in extraction and microextraction procedures, as sensors, and as stationary or pseudo-stationary phases in chromatographic systems. To date, around 100 different MOFs form part of those analytical applications. This review intends to give an overview on the use of MOFs in analytical chemistry in recent years (2017–2019) within the framework of green analytical chemistry requirements, with a particular emphasis on possible toxicity issues of neat MOFs and trends to ensure green approaches in their preparation.
Collapse
|
27
|
Jia X, Zhao J, Ren H, Wang J, Hong Z, Zhang X. Zwitterion-functionalized polymer microspheres-based solid phase extraction method on-line combined with HPLC–ICP-MS for mercury speciation. Talanta 2019; 196:592-599. [DOI: 10.1016/j.talanta.2019.01.013] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2018] [Revised: 12/25/2018] [Accepted: 01/02/2019] [Indexed: 10/27/2022]
|
28
|
Hashemi SH, Yahyavi H, Kaykhaii M, Hashemi M, Mirmoghaddam M, Keikha AJ. Spectrofluorometrical Determination of Vitamin B
1
in Different Matrices Using Box‐Behnken Designed Pipette Tip Solid Phase Extraction by a Carbon Nanotube Sorbent. ChemistrySelect 2019. [DOI: 10.1002/slct.201803731] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Sayyed Hossein Hashemi
- Department of Marine ChemistryFaculty of Marine ScienceChabahar Maritime University Chabahar Iran
| | - Hossein Yahyavi
- Department of ChemistryFaculty of SciencesUniversity of Sistan and Baluchestan Zahedan Iran
| | - Massoud Kaykhaii
- Department of ChemistryFaculty of SciencesUniversity of Sistan and Baluchestan Zahedan Iran
| | - Mohammad Hashemi
- Department of BiochemistrySchool of MedicineZahedan University of Medical Sciences Zahedan, Iran
| | - Majid Mirmoghaddam
- Department of ChemistryFaculty of SciencesUniversity of Sistan and Baluchestan Zahedan Iran
| | - Ahmad Jamali Keikha
- Department of Mechanical EngineeringFaculty of Marine EngineeringChabahar Maritime University Chabahar Iran
| |
Collapse
|
29
|
Rocío-Bautista P, Termopoli V. Metal–Organic Frameworks in Solid-Phase Extraction Procedures for Environmental and Food Analyses. Chromatographia 2019. [DOI: 10.1007/s10337-019-03706-z] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
30
|
Iron species supported on a mesoporous zirconium metal-organic framework for visible light driven synthesis of quinazolin-4(3H)-ones through one-pot three-step tandem reaction. J Colloid Interface Sci 2019; 535:214-226. [DOI: 10.1016/j.jcis.2018.09.099] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Revised: 09/12/2018] [Accepted: 09/27/2018] [Indexed: 12/23/2022]
|
31
|
Miri MG, Khajeh M, Oveisi AR, Bohlooli M. Urea-based porous organic polymer/graphene oxide hybrid as a new sorbent for highly efficient extraction of bovine serum albumin prior to its spectrophotometric determination. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2018; 205:200-206. [PMID: 30015026 DOI: 10.1016/j.saa.2018.07.034] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2017] [Revised: 07/08/2018] [Accepted: 07/10/2018] [Indexed: 06/08/2023]
Abstract
A 3D urea-based porous organic polymer (Urea-POP) was prepared via the reaction of tetrakis(4-aminophenyl)methane and 1,4-Phenylene diisocyanate. The polymer was subsequently reacted with 2D layered nanosheets of graphene oxide (GO) to prepare Urea-POP/GO as a novel and highly efficient sorbent for pre-concentration and extraction of serum albumin samples, prior to spectrophotometric determination. The hybrid material combines advantages of both POP and GO such as hydrophilicity, high dispersion stability, porosity, and having a large number of nitrogen- and oxygen-containing functional groups. Parameters which influence the extraction efficiency such as the amount of the adsorbent, pH of sample solution, ionic strength, adsorption and desorption time were investigated and optimized. For the method, detection limit of 0.068 mg L-1 and determination coefficient (R2) of 0.9991 were obtained. The intra- and inter-day was calculated with five replicates in the same day and seven consecutive days, respectively. Intra-day and inter-day precisions were 1.7% and 5.9%, respectively. The maximum sorption capacity was 357.1 mg g-1, which is higher than the other reported sorbents. The proposed method was demonstrated to be sensitive enough for determination of serum albumin from bio-samples.
Collapse
Affiliation(s)
| | - Mostafa Khajeh
- Department of Chemistry, University of Zabol, Zabol, Iran.
| | | | | |
Collapse
|
32
|
A hybrid material composed of an amino-functionalized zirconium-based metal-organic framework and a urea-based porous organic polymer as an efficient sorbent for extraction of uranium(VI). Mikrochim Acta 2018; 185:469. [DOI: 10.1007/s00604-018-2991-3] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2018] [Accepted: 09/01/2018] [Indexed: 10/28/2022]
|
33
|
Wang X, Duan HL, Ma SY, Wang J, Zhan HY, Zhang ZQ. Selective adsorption and separation of illegal cationic dyes from foodstuffs with anionic polyelectrolyte functionalised metal-organic frameworks. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2018; 35:1870-1880. [DOI: 10.1080/19440049.2018.1492154] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Xue Wang
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province and Key Laboratory of Medicinal Resources and Natural Pharmaceutical Chemistry of the Ministry of Education, Shaanxi Normal University, Xi’an, China
| | - Hui-Ling Duan
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province and Key Laboratory of Medicinal Resources and Natural Pharmaceutical Chemistry of the Ministry of Education, Shaanxi Normal University, Xi’an, China
| | - Shi-Yao Ma
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province and Key Laboratory of Medicinal Resources and Natural Pharmaceutical Chemistry of the Ministry of Education, Shaanxi Normal University, Xi’an, China
| | - Jun Wang
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province and Key Laboratory of Medicinal Resources and Natural Pharmaceutical Chemistry of the Ministry of Education, Shaanxi Normal University, Xi’an, China
| | - Han-Ying Zhan
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province and Key Laboratory of Medicinal Resources and Natural Pharmaceutical Chemistry of the Ministry of Education, Shaanxi Normal University, Xi’an, China
| | - Zhi-Qi Zhang
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province and Key Laboratory of Medicinal Resources and Natural Pharmaceutical Chemistry of the Ministry of Education, Shaanxi Normal University, Xi’an, China
| |
Collapse
|
34
|
Rezaei Kahkha MR, Oveisi AR, Kaykhaii M, Rezaei Kahkha B. Determination of carbamazepine in urine and water samples using amino-functionalized metal-organic framework as sorbent. Chem Cent J 2018; 12:77. [PMID: 29961226 PMCID: PMC6026485 DOI: 10.1186/s13065-018-0446-x] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Accepted: 06/26/2018] [Indexed: 11/24/2022] Open
Abstract
A stable and porous amino-functionalized zirconium-based metal organic framework (Zr-MOF-NH2) containing missing linker defects was prepared and fully characterized by FTIR, scanning electron microscopy, powder X-ray diffraction, and BET surface area measurement. The Zr-MOF-NH2 was then applied as an adsorbent in pipette-tip solid phase extraction (PT-SPE) of carbamazepine. Important parameters affecting extraction efficiency such as pH, sample volume, type and volume of eluent, amount of adsorbent, and number of aspirating/dispensing cycles for sample solution and eluent solvent were investigated and optimized. The best extraction efficiency was obtained when pH of 100 µL of sample solution was adjusted to 7.5 and 5 mg of the sorbent was used. Eluent solvent was 10 µL methanol. Linear dynamic range was found to be between 0.1 and 50 µg L−1 and limit of detection for 10 measurement of blank solution was 0.05 µg L−1. This extraction method was coupled to HPLC and was successfully employed for the determination of carbamazepine in urine and water samples. The strategy combined the advantages of fast and easy operation of PT-SPE with robustness and large adsorption capacity of Zr-MOF-NH2.
Collapse
Affiliation(s)
- Mohammad Reza Rezaei Kahkha
- Department of Environmental Health Engineering, Faculty of Health, Zabol University of Medical Sciences, Zabol, Iran. .,Zabol Medicinal Plants Reseach Center, Zabol University of Medical Sciences, Zabol, Iran.
| | | | - Massoud Kaykhaii
- Department of Chemistry, Faculty of Sciences, University of Sistan and Baluchestan, Zahedan, Iran.,Smartphone Analytical Sensors Research Centre, University of Sistan and Baluchestan, Zahedan, Iran
| | - Batool Rezaei Kahkha
- Department of Environmental Health Engineering, Faculty of Health, Zabol University of Medical Sciences, Zabol, Iran
| |
Collapse
|
35
|
An Extraction Method for Determination of 6-Benzyladenine in Bean Sprout by Graphene Oxide/Polypyrrole Composite Adsorbent. FOOD ANAL METHOD 2018. [DOI: 10.1007/s12161-018-1168-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|