1
|
Saito S, Ueda J. Preclinical magnetic resonance imaging and spectroscopy in the fields of radiological technology, medical physics, and radiology. Radiol Phys Technol 2024; 17:47-59. [PMID: 38351261 PMCID: PMC10901953 DOI: 10.1007/s12194-024-00785-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Revised: 01/18/2024] [Accepted: 01/20/2024] [Indexed: 03/01/2024]
Abstract
Magnetic resonance imaging (MRI) is an indispensable diagnostic imaging technique used in the clinical setting. MRI is advantageous over X-ray and computed tomography (CT), because the contrast provided depends on differences in the density of various organ tissues. In addition to MRI systems in hospitals, more than 100 systems are used for research purposes in Japan in various fields, including basic scientific research, molecular and clinical investigations, and life science research, such as drug discovery, veterinary medicine, and food testing. For many years, additional preclinical imaging studies have been conducted in basic research in the fields of radiation technology, medical physics, and radiology. The preclinical MRI research includes studies using small-bore and whole-body MRI systems. In this review, we focus on the animal study using small-bore MRI systems as "preclinical MRI". The preclinical MRI can be used to elucidate the pathophysiology of diseases and for translational research. This review will provide an overview of previous preclinical MRI studies such as brain, heart, and liver disease assessments. Also, we provide an overview of the utility of preclinical MRI studies in radiological physics and technology.
Collapse
Affiliation(s)
- Shigeyoshi Saito
- Department of Medical Physics and Engineering, Area of Medical Imaging Technology and Science, Division of Health Sciences, Osaka University Graduate School of Medicine, Suita, Osaka, 560-0871, Japan.
- Department of Advanced Medical Technologies, National Cerebral and Cardiovascular Center Research Institute, Suita, 564-8565, Japan.
| | - Junpei Ueda
- Department of Medical Physics and Engineering, Area of Medical Imaging Technology and Science, Division of Health Sciences, Osaka University Graduate School of Medicine, Suita, Osaka, 560-0871, Japan
| |
Collapse
|
2
|
Huang CFJ, Lin WL, Hwang SC, Yao C, Chang H, Chen YY, Kuo LW. A feasibility study of wireless inductively coupled surface coil for MR-guided high-intensity focused ultrasound ablation of rodents on clinical MRI systems. Sci Rep 2022; 12:21907. [PMID: 36536022 PMCID: PMC9763396 DOI: 10.1038/s41598-022-26452-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Accepted: 12/14/2022] [Indexed: 12/23/2022] Open
Abstract
Recently, to conduct preclinical imaging research on clinical MRI systems has become an attractive alternative to researchers due to its wide availability, cost, and translational application to clinical human studies when compared to dedicated small animal, high-field preclinical MRI. However, insufficient signal-to-noise ratio (SNR) significantly degrades the applicability of those applications which require high SNR, e.g. magnetic resonance guided high-intensity focused ultrasound (MRgHIFU) treatment. This study introduces a wireless inductively coupled surface (WICS) coil design used on a clinical 3 T MRI system for MRgHIFU ablation. To evaluate the SNR improvement and temperature accuracy of WICS coil, the ex vivo experiments were performed on the pork tenderloins (n = 7) and the hind legs of deceased Sprague-Dawley rats (n = 5). To demonstrate the feasibility, the in vivo experiments were performed on the hind leg of Sprague-Dawley rat (n = 1). For all experiments, temperature measurements were performed before and during HIFU ablation. Temperature curves with and without WICS coil were compared to evaluate the temperature precision in ex vivo experiments. The use of WICS coil improves the temperature accuracy from 0.85 to 0.14 °C, demonstrating the feasibility of performing small animal MRgHIFU experiments using clinical 3 T MRI system with WICS coil.
Collapse
Affiliation(s)
- Chien-Feng Judith Huang
- grid.19188.390000 0004 0546 0241Department of Biomedical Engineering, National Taiwan University, Taipei, 100233 Taiwan ,grid.59784.370000000406229172Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, 35053 Taiwan
| | - Win-Li Lin
- grid.19188.390000 0004 0546 0241Department of Biomedical Engineering, National Taiwan University, Taipei, 100233 Taiwan ,grid.59784.370000000406229172Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, 35053 Taiwan
| | - San-Chao Hwang
- MBInsight Technology Corporation, New Taipei City, 236658 Taiwan
| | - Ching Yao
- MBInsight Technology Corporation, New Taipei City, 236658 Taiwan
| | - Hsu Chang
- MBInsight Technology Corporation, New Taipei City, 236658 Taiwan
| | - Yung-Yaw Chen
- grid.19188.390000 0004 0546 0241Department of Electrical Engineering, National Taiwan University, Taipei, 100233 Taiwan
| | - Li-Wei Kuo
- grid.59784.370000000406229172Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, 35053 Taiwan ,grid.19188.390000 0004 0546 0241Institute of Medical Device and Imaging, National Taiwan University, Taipei, 100233 Taiwan
| |
Collapse
|
3
|
Nakano A, Kawashima H, Miyake Y, Zeniya T, Yamamoto A, Koshino K, Temma T, Fukuda T, Fujita Y, Kakino A, Kanaya S, Sawamura T, Iida H. 123I-Labeled oxLDL Is Widely Distributed Throughout the Whole Body in Mice. Nucl Med Mol Imaging 2017; 52:144-153. [PMID: 29662563 DOI: 10.1007/s13139-017-0497-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2017] [Revised: 09/13/2017] [Accepted: 09/13/2017] [Indexed: 01/14/2023] Open
Abstract
Purpose Oxidized low-density lipoprotein (oxLDL) plays a key role in endothelial dysfunction, vascular inflammation, and atherogenesis. The aim of this study was to assess blood clearance and in vivo kinetics of radiolabeled oxLDL in mice. Methods We synthesized 123I-oxLDL by the iodine monochloride method, and performed an uptake study in CHO cells transfected with lectin-like oxLDL receptor-1 (LOX-1). In addition, we evaluated the consistency between the 123I-oxLDL autoradiogram and the fluorescence image of DiI-oxLDL after intravenous injection for both spleen and liver. Whole-body dynamic planar images were acquired 10 min post injection of 123I-oxLDL to generate regional time-activity curves (TACs) of the liver, heart, lungs, kidney, head, and abdomen. Regional radioactivity for those excised tissues as well as the bladder, stomach, gut, and thyroid were assessed using a gamma counter, yielding percent injected dose (%ID) and dose uptake ratio (DUR). The presence of 123I-oxLDL in serum was assessed by radio-HPLC. Results The cellular uptakes of 123I-oxLDL were identical to those of DiI-oxLDL, and autoradiograms and fluorescence images also exhibited consistent distributions. TACs after injection of 123I-oxLDL demonstrated extremely fast kinetics. The radioactivity uptake at 10 min post-injection was highest in the liver (40.8 ± 2.4% ID). Notably, radioactivity uptake was equivalent throughout the rest of the body (39.4 ± 2.7% ID). HPLC analysis revealed no remaining 123I-oxLDL or its metabolites in the blood. Conclusion 123I-OxLDL was widely distributed not only in the liver, but also throughout the whole body, providing insight into the pathophysiological effects of oxLDL.
Collapse
Affiliation(s)
- Atushi Nakano
- 1Department of Investigative Radiology, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565 Japan.,2Department of Vascular Physiology, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, Japan
| | - Hidekazu Kawashima
- 1Department of Investigative Radiology, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565 Japan.,3Radioisotope Research Center, Kyoto Pharmaceutical University, 1 Misasagi-shichono-cho, Yamashina-ku, Kyoto, Japan
| | - Yoshinori Miyake
- 1Department of Investigative Radiology, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565 Japan
| | - Tsutomu Zeniya
- 1Department of Investigative Radiology, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565 Japan.,4Graduate School of Science and Technology, Hirosaki University, Bunkyo-cho, Hirosaki, Aomori, Japan
| | - Akihide Yamamoto
- 1Department of Investigative Radiology, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565 Japan
| | - Kazuhiro Koshino
- 1Department of Investigative Radiology, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565 Japan
| | - Takashi Temma
- 1Department of Investigative Radiology, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565 Japan.,5Department of Biofunctional Analysis, Osaka University of Pharmaceutical Sciences, 4-20-1 Nasahara, Takatsuki, Osaka, Japan
| | - Tetsuya Fukuda
- Department Radiology, National Cerebral and Cardiovacular Center, 5-7-1 Fujishiro-dai, Suita, Osaka, Japan
| | - Yoshiko Fujita
- 7Department of Physiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, Japan
| | - Akemi Kakino
- 7Department of Physiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, Japan
| | - Shigehiko Kanaya
- Computational Systems Biology Laboratory, Graduate School of Information Science, Nara Institute of Science and Techonology, Takayama, Nara, Japan
| | - Tatsuya Sawamura
- 7Department of Physiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, Japan
| | - Hidehiro Iida
- 1Department of Investigative Radiology, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565 Japan.,Department Radiology, National Cerebral and Cardiovacular Center, 5-7-1 Fujishiro-dai, Suita, Osaka, Japan.,Computational Systems Biology Laboratory, Graduate School of Information Science, Nara Institute of Science and Techonology, Takayama, Nara, Japan
| |
Collapse
|
4
|
Krämer M, Herrmann KH, Biermann J, Freiburger S, Schwarzer M, Reichenbach JR. Self-gated cardiac Cine MRI of the rat on a clinical 3 T MRI system. NMR IN BIOMEDICINE 2015; 28:162-167. [PMID: 25417764 DOI: 10.1002/nbm.3234] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2014] [Revised: 10/09/2014] [Accepted: 10/11/2014] [Indexed: 06/04/2023]
Abstract
The ability to perform small animal functional cardiac imaging on clinical MRI scanners may be of particular value in cases in which the availability of a dedicated high field animal MRI scanner is limited. Here, we propose radial MR cardiac imaging in the rat on a whole-body clinical 3 T scanner in combination with interspersed projection navigators for self-gating without any additional external triggering requirements for electrocardiogram (ECG) and respiration. Single navigator readouts were interspersed using the same TR and a high navigator frequency of 54 Hz into a radial golden-angle acquisition. The extracted navigator function was thresholded to exclude data for reconstruction from inhalation phases during the breathing cycle, enabling free breathing acquisition. To minimize flow artifacts in the dynamic cine images a center-out half echo radial acquisition scheme with ramp sampling was used. Navigator functions were derived from the corresponding projection navigator data from which both respiration and cardiac cycles were extracted. Self-gated cine acquisition resulted in high-quality cardiac images which were free of major artifacts with spatial resolution of up to 0.21 × 0.21 × 1.00 mm(3) and a contrast-to-noise ratio (CNR) of 21 ± 3 between the myocardium and left ventricle. Self-gated golden ratio based radial acquisition successfully acquired cine images of the rat heart on a clinical MRI system without the need for dedicated animal ECG equipment.
Collapse
Affiliation(s)
- Martin Krämer
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital - Friedrich Schiller University Jena, Philosophenweg 3, D-07743, Jena, Germany
| | | | | | | | | | | |
Collapse
|
5
|
3D printing of MRI compatible components: Why every MRI research group should have a low-budget 3D printer. Med Eng Phys 2014; 36:1373-80. [DOI: 10.1016/j.medengphy.2014.06.008] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Revised: 04/30/2014] [Accepted: 06/15/2014] [Indexed: 01/16/2023]
|
6
|
Peng SL, Wang FN, Wang CH, Peng HH, Lu CT, Yeh CK. Using microbubbles as an MRI contrast agent for the measurement of cerebral blood volume. NMR IN BIOMEDICINE 2013; 26:1540-1546. [PMID: 23794141 DOI: 10.1002/nbm.2988] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2012] [Revised: 05/17/2013] [Accepted: 05/17/2013] [Indexed: 06/02/2023]
Abstract
The susceptibility differences at the gas-liquid interface of microbubbles (MBs) allow their use as an intravascular susceptibility contrast agent for in vivo MRI. However, the characteristics of MBs are very different from those of the standard gadolinium-diethylenetriaminepentaacetic acid (Gd-DPTA) contrast agent, including the size distribution and hemodynamic properties, which could influence MRI outcomes. Here, we investigate quantitatively the correlation between the relative cerebral blood volume (rCBV) derived from Gd-DTPA (rCBV(Gd)) and the MB-induced susceptibility effect (ΔR(2*MB)) by conventional dynamic susceptibility contrast MRI (DSC-MRI). Custom-made MBs had a mean diameter of 0.92 µm and were capable of inducing 4.68 ± 3.02% of the maximum signal change (MSC). The MB-associated ΔR(2*MB) was compared with rCBV(Gd) in 16 rats on 4.7-T MRI. We observed a significant effect of the time to peak (TTP) on the correlation between ΔR(2*MB) and rCBV(Gd), and also found a noticeable dependence between TTP and MSC. Our findings suggest that MBs with longer TTPs can be used for the estimation of rCBV by DSC-MRI, and emphasize the critical effect of TTP on MB-based contrast MRI.
Collapse
Affiliation(s)
- Shin-Lei Peng
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan
| | | | | | | | | | | |
Collapse
|
7
|
Herrmann KH, Pfeiffer N, Krumbein I, Herrmann L, Reichenbach JR. MRI compatible small animal monitoring and trigger system for whole body scanners. Z Med Phys 2013; 24:55-64. [PMID: 23962379 DOI: 10.1016/j.zemedi.2013.07.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2012] [Revised: 07/16/2013] [Accepted: 07/16/2013] [Indexed: 02/03/2023]
Abstract
Performing magnetic resonance imaging (MRI) experiments with small animals requires continuous monitoring of vital parameters, especially the respiration rate. Clinical whole-body MR scanners represent an attractive option for preclinical imaging as dedicated animal scanners are cost-intensive in both investment and maintenance, thus limiting their availability. Even though impressive image quality is achievable with clinical MR systems in combination with special coils, their built-in physiologic monitoring and triggering units are often not suited for small animal imaging. In this work, we present a simple, MRI compatible low cost solution to monitor the respiration and heart rate of small animals in a clinical whole-body MR scanner. The recording and processing of the biosignals as well as the optimisation of the respiratory trigger generation is decribed. Additionally rat and mouse in-vivo MRI experiments are presented to illustrate the effectiveness of the monitoring and respiratory trigger system in suppressing motion artifacts.
Collapse
Affiliation(s)
- Karl-Heinz Herrmann
- Medical Physics Group, Institute for Diagnostic and Interventional Radiology I, Jena University Hospital, Philosophenweg 3, Gebäude 5, 07743 Jena, Germany.
| | - Norman Pfeiffer
- Medical Physics Group, Institute for Diagnostic and Interventional Radiology I, Jena University Hospital, Philosophenweg 3, Gebäude 5, 07743 Jena, Germany; Ernst-Abbe-Fachhochschule Jena, Carl-Zeiss-Promenade 2, 07745 Jena, Germany
| | - Ines Krumbein
- Medical Physics Group, Institute for Diagnostic and Interventional Radiology I, Jena University Hospital, Philosophenweg 3, Gebäude 5, 07743 Jena, Germany
| | - Lutz Herrmann
- Ernst-Abbe-Fachhochschule Jena, Carl-Zeiss-Promenade 2, 07745 Jena, Germany
| | - Jürgen R Reichenbach
- Medical Physics Group, Institute for Diagnostic and Interventional Radiology I, Jena University Hospital, Philosophenweg 3, Gebäude 5, 07743 Jena, Germany
| |
Collapse
|
8
|
Mystkowska D, Tutas A, Jezierska-Woźniak K, Mikołajczyk A, Bobek-Billewicz B, Jurkowski M. Usefulness of clinical magnetic resonance scanners for imaging experimental changes in laboratory rodents' central nervous system. ACTA ACUST UNITED AC 2012. [DOI: 10.1016/j.poamed.2012.04.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
9
|
Zeniya T, Watabe H, Hayashi T, Ose T, Myojin K, Taguchi A, Yamamoto A, Teramoto N, Kanagawa M, Yamamichi Y, Iida H. Three-dimensional quantitation of regional cerebral blood flow in mice using a high-resolution pinhole SPECT system and 123I-iodoamphetamine. Nucl Med Biol 2011; 38:1157-64. [PMID: 21741253 DOI: 10.1016/j.nucmedbio.2011.04.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2010] [Revised: 03/28/2011] [Accepted: 04/23/2011] [Indexed: 11/29/2022]
Abstract
INTRODUCTION This study is intended to evaluate the feasibility of using a high-resolution pinhole SPECT system and iodine-123-N-isopropyl-4-iodoamphetamine ((123)I-IMP) for three-dimensional (3D) absolute quantitation of regional cerebral blood flow (rCBF) in mice. METHODS The pinhole SPECT system consists of a rotating stage and a pinhole collimator attached to a clinical gamma camera. The collimator's focal length is 251 mm. Phantom studies were performed to evaluate sensitivity and full-width half-maximum (FWHM) spatial resolution. The aperture-to-object distance was 15 mm. Six mice were studied. Cerebral infarctions were induced by ligating and disconnecting the distal portion of the left middle cerebral artery. Ex vivo SPECT studies were performed using harvested brains and skulls. The CBF volumetric image was computed using the standardized input function. RESULTS Excellent spatial resolution of 0.9-mm FWHM and uniform sensitivity throughout the 3D volume were demonstrated in the phantom experiments. The CBF images showed a defect in the infarcted areas and a reduction of CBF values in the infarcted region as compared with the control region. CONCLUSIONS This study demonstrated the feasibility of the 3D quantitation of rCBF in mice using a high-resolution pinhole SPECT system and (123)I-IMP.
Collapse
Affiliation(s)
- Tsutomu Zeniya
- Department of Investigative Radiology, National Cerebral and Cardiovascular Center Research Institute, Suita, Osaka, Japan.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Yamanami M, Yamamoto A, Iida H, Watanabe T, Kanda K, Yaku H, Nakayama Y. 3-Tesla magnetic resonance angiographic assessment of a tissue-engineered small-caliber vascular graft implanted in a rat. J Biomed Mater Res B Appl Biomater 2010; 92:156-60. [PMID: 19802838 DOI: 10.1002/jbm.b.31501] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
In the development of small-caliber vascular grafts (diameter; less than 3 mm), animal implantation studies have been mostly performed by using rat abdominal aortas, and their certain patency must evaluate with sacrificing every observation periods, which is both labor-intensive and time-consuming when performing a large number of experiments. This study is the first to demonstrate the application of 3-Tesla contrast-free time-of-flight magnetic resonance angiography (TOF-MRA) in the continuous assessment of the status of a tissue-engineered vascular graft in rat. As a model graft, a single connective tubular tissue (diameter; 1.5 mm), prepared by embedding the silicone rod (diameter; 1.5 mm) into a subcutaneous pouch of a rat for 2 weeks an in vivo tissue-engineering, was used. The graft was implanted in the abdominal aorta (diameter; 1.3 mm) of the rat by end-to-end anastomosis. Repeated TOF-MRA imaging of the graft obtained over a 3-month follow-up period after implantation made it possible to evaluate the patency of the graft, both simply and noninvasively. It also permitted visualization of the connected abdominal aorta and renal and common iliac arteries having smaller caliber (diameter; less than 1 mm). In addition, the degree of the stenosis or aneurysm could also be detected. 3-Tesla MRA allowed the simplified and noninvasive assessment of the status on the vascular graft, including the formation of a stenosis or aneurysm, in the same rat at different times, which will be contributing to enhance the development of tissue-engineered vascular grafts even with small caliber.
Collapse
Affiliation(s)
- Masashi Yamanami
- Department of Bioengineering, Advanced Biomedical Engineering Center, National Cardiovascular Center Research Institute, Osaka, Japan
| | | | | | | | | | | | | |
Collapse
|