1
|
Talbot FO, Suarez CM, Nagy AM, Chen JC, Djavani-Tabrizi I, Clotea I, Jockusch RA. Robust Fluorescence Collection Module for Wide-Bore Ion Cyclotron Resonance Mass Spectrometers. Anal Chem 2023; 95:17193-17202. [PMID: 37963234 DOI: 10.1021/acs.analchem.3c01801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2023]
Abstract
Mass spectrometers are at the heart of the most powerful toolboxes available to scientists when studying molecular structure, conformation, and dynamics in controlled molecular environments. Improved molecular characterization brought about by the implementation of new orthogonal methods into mass spectrometry-enabled analyses opens deeper insight into the complex interplay of forces that underlie chemistry. Here, we detail how one can add fluorescence detection to commercial ultrahigh-resolution Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers without adverse effects to its preexisting analytical tools. This advance enables measurements based on fluorescence detection, such as Förster resonance energy transfer (FRET), to be used in conjunction with other MS/MS techniques to probe the conformation and dynamics of large biomolecules, such as proteins and their complexes, in the highly controlled environment of a Penning trap.
Collapse
Affiliation(s)
- Francis O Talbot
- Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
| | - Cynthia M Suarez
- Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
| | - Andrea M Nagy
- Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
| | - JoAnn C Chen
- Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
| | - Iden Djavani-Tabrizi
- Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
| | - Ioana Clotea
- Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
| | - Rebecca A Jockusch
- Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
| |
Collapse
|
2
|
Lopes T, Fidelis CE, Silva ATF, Mota RA, Rall VLM, Dos Santos MV, Gonçalves JL. MALDI-TOF bacterial subtyping for rapid detection of biomarkers in Staphylococcus aureus from subclinical bovine mastitis. J Appl Microbiol 2023; 134:lxad249. [PMID: 37930722 DOI: 10.1093/jambio/lxad249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 10/12/2023] [Accepted: 10/30/2023] [Indexed: 11/07/2023]
Abstract
AIMS This study aimed to evaluate matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) bacterial subtyping for the rapid detection of biomarkers in Staphylococcus aureus from subclinical bovine mastitis. METHODS AND RESULTS A total of 229 S. aureus isolates were obtained from milk samples collected from cows with subclinical mastitis using microbiological culture. Staphylococcus aureus isolates were also submitted to PCR analysis targeting the mecA and mecC genes, which are indicative of methicillin resistance. Confirmation of the species was achieved through MALDI-TOF MS analysis. To analyze antimicrobial resistance patterns, the MALDI BioTyper Compass Explorer and ClinProTools Bruker software were employed, and dendrograms were generated using Bionumerics software. CONCLUSIONS MALDI-TOF MS successfully identified S. aureus at the species level, but no methicillin resistance was observed. Moreover, spectral typing displayed limited similarity when compared to pulsed-field gel electrophoresis (PFGE).
Collapse
Affiliation(s)
- Thainara Lopes
- School of Animal Science and Food Engineering, University of São Paulo, Pirassununga 13635-900, Brazil
| | - Carlos E Fidelis
- Qualileite, Department of Animal Nutrition and Production, School of Veterinary Medicine and Animal Sciences, University of São Paulo, Pirassununga 13635-900, Brazil
| | - Amanda T F Silva
- Department of Veterinary Medicine, Federal Rural University of Pernambuco, Recife 52171-900, Brazil
| | - Rinaldo A Mota
- Department of Veterinary Medicine, Federal Rural University of Pernambuco, Recife 52171-900, Brazil
| | - Vera L M Rall
- Department of Chemical and Biological Sciences, Institute of Biosciences, São Paulo State University, Botucatu 18618-689, Brazil
| | - Marcos V Dos Santos
- Qualileite, Department of Animal Nutrition and Production, School of Veterinary Medicine and Animal Sciences, University of São Paulo, Pirassununga 13635-900, Brazil
| | - Juliano L Gonçalves
- Qualileite, Department of Animal Nutrition and Production, School of Veterinary Medicine and Animal Sciences, University of São Paulo, Pirassununga 13635-900, Brazil
- Department of Large Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing 48824, USA
| |
Collapse
|
3
|
Thompson JE. Matrix-assisted laser desorption ionization-time-of-flight mass spectrometry in veterinary medicine: Recent advances (2019-present). Vet World 2022; 15:2623-2657. [PMID: 36590115 PMCID: PMC9798047 DOI: 10.14202/vetworld.2022.2623-2657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Accepted: 10/11/2022] [Indexed: 11/22/2022] Open
Abstract
Matrix-assisted laser desorption ionization-time-of-flight (MALDI-TOF) mass spectrometry (MS) has become a valuable laboratory tool for rapid diagnostics, research, and exploration in veterinary medicine. While instrument acquisition costs are high for the technology, cost per sample is very low, the method requires minimal sample preparation, and analysis is easily conducted by end-users requiring minimal training. Matrix-assisted laser desorption ionization-time-of-flight MS has found widespread application for the rapid identification of microorganisms, diagnosis of dermatophytes and parasites, protein/lipid profiling, molecular diagnostics, and the technique demonstrates significant promise for 2D chemical mapping of tissue sections collected postmortem. In this review, an overview of the MALDI-TOF technique will be reported and manuscripts outlining current uses of the technology for veterinary science since 2019 will be summarized. The article concludes by discussing gaps in knowledge and areas of future growth.
Collapse
Affiliation(s)
- Jonathan E. Thompson
- School of Veterinary Medicine, Texas Tech University, Amarillo, Texas 79106, United States,Corresponding author: Jonathan E. Thompson, e-mail:
| |
Collapse
|
4
|
“Omic” Approaches to Bacteria and Antibiotic Resistance Identification. Int J Mol Sci 2022; 23:ijms23179601. [PMID: 36077000 PMCID: PMC9455953 DOI: 10.3390/ijms23179601] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 08/19/2022] [Accepted: 08/21/2022] [Indexed: 11/28/2022] Open
Abstract
The quick and accurate identification of microorganisms and the study of resistance to antibiotics is crucial in the economic and industrial fields along with medicine. One of the fastest-growing identification methods is the spectrometric approach consisting in the matrix-assisted laser ionization/desorption using a time-of-flight analyzer (MALDI-TOF MS), which has many advantages over conventional methods for the determination of microorganisms presented. Thanks to the use of a multiomic approach in the MALDI-TOF MS analysis, it is possible to obtain a broad spectrum of data allowing the identification of microorganisms, understanding their interactions and the analysis of antibiotic resistance mechanisms. In addition, the literature data indicate the possibility of a significant reduction in the time of the sample preparation and analysis time, which will enable a faster initiation of the treatment of patients. However, it is still necessary to improve the process of identifying and supplementing the existing databases along with creating new ones. This review summarizes the use of “-omics” approaches in the MALDI TOF MS analysis, including in bacterial identification and antibiotic resistance mechanisms analysis.
Collapse
|
5
|
Horká M, Růžička F, Siváková A, Karásek P, Šalplachta J, Pantůček R, Roth M. Capillary electrophoretic methods for classification of methicillin-resistant Staphylococcus aureus (MRSA) clones. Anal Chim Acta 2022; 1227:340305. [DOI: 10.1016/j.aca.2022.340305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 08/19/2022] [Accepted: 08/20/2022] [Indexed: 11/26/2022]
|
6
|
Lin H, Hu Z, Wu J, Lu Y, Chen J, Wu W. Methodology Establishment and Application of VITEK Mass Spectrometry to Detect Carbapenemase-Producing Klebsiella pneumoniae. Front Cell Infect Microbiol 2022; 12:761328. [PMID: 35223536 PMCID: PMC8873529 DOI: 10.3389/fcimb.2022.761328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Accepted: 01/14/2022] [Indexed: 11/13/2022] Open
Abstract
The ability of VITEK mass spectrometry (MS) in detection of bacterial resistance is currently under exploration and evaluation. In this study, we developed and validated a VITEK MS method to rapidly test carbapenemase-producing Klebsiella pneumoniae (CPKP). Solvents, antibiotic concentrations, crystal conditions and times, centrifugation speeds, and other factors were optimized to design a rapid sample pretreatment process for CPKP detection by VITEK MS. The related parameters of the mass spectrum were adjusted on the instrument to establish an CPKP detection mode. 133 clinically isolated strains of CPKP in the microbiology laboratory at the Shenzhen People’s Hospital from 2004 to 2017 were selected for accuracy evaluation. The fresh suspected strains from the microbiology laboratory in 2020 were used to complete the clinical verification. Two antibiotics, meropenem (MEM) and imipenem (IPM), were used as substrates. These two substrates were incubated with suspected CPKP, and the results were obtained by VITEK MS detection. Using this method, different types of CPKP showed different detection results and all the CPKP strains producing KPC-2 and IMP-4 carbapenemase were detected by VITEK MS. Thus, VITEK MS can be used for rapid detection of CPKP, especially for some common types of CPKP. This method provides high accuracy and speed of detection. Combined with its cost advantages, it can be intensely valuable in clinical microbiology laboratories after the standard operating procedures are determined.
Collapse
|
7
|
Recent Developments in Phenotypic and Molecular Diagnostic Methods for Antimicrobial Resistance Detection in Staphylococcus aureus: A Narrative Review. Diagnostics (Basel) 2022; 12:diagnostics12010208. [PMID: 35054375 PMCID: PMC8774325 DOI: 10.3390/diagnostics12010208] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 01/12/2022] [Accepted: 01/13/2022] [Indexed: 11/17/2022] Open
Abstract
Staphylococcus aureus is an opportunistic pathogen responsible for a wide range of infections in humans, such as skin and soft tissue infections, pneumonia, food poisoning or sepsis. Historically, S. aureus was able to rapidly adapt to anti-staphylococcal antibiotics and become resistant to several classes of antibiotics. Today, methicillin-resistant S. aureus (MRSA) is a multidrug-resistant pathogen and is one of the most common bacteria responsible for hospital-acquired infections and outbreaks, in community settings as well. The rapid and accurate diagnosis of antimicrobial resistance in S. aureus is crucial to the early initiation of directed antibiotic therapy and to improve clinical outcomes for patients. In this narrative review, I provide an overview of recent phenotypic and molecular diagnostic methods for antimicrobial resistance detection in S. aureus, with a particular focus on MRSA detection. I consider methods for resistance detection in both clinical samples and isolated S. aureus cultures, along with a brief discussion of the advantages and the challenges of implementing such methods in routine diagnostics.
Collapse
|
8
|
Neil JR, Verma A, Kronewitter SR, McGee WM, Mullen C, Viirtola M, Kotovuori A, Friedrich H, Finell J, Rannisto J, Syka JEP, Stephenson JL. Rapid MRSA detection via tandem mass spectrometry of the intact 80 kDa PBP2a resistance protein. Sci Rep 2021; 11:18309. [PMID: 34526615 PMCID: PMC8443585 DOI: 10.1038/s41598-021-97844-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Accepted: 08/30/2021] [Indexed: 02/08/2023] Open
Abstract
Treatment of antibiotic-resistant infections is dependent on the detection of specific bacterial genes or proteins in clinical assays. Identification of methicillin-resistant Staphylococcus aureus (MRSA) is often accomplished through the detection of penicillin-binding protein 2a (PBP2a). With greater dependence on mass spectrometry (MS)-based bacterial identification, complementary efforts to detect resistance have been hindered by the complexity of those proteins responsible. Initial characterization of PBP2a indicates the presence of glycan modifications. To simplify detection, we demonstrate a proof-of-concept tandem MS approach involving the generation of N-terminal PBP2a peptide-like fragments and detection of unique product ions during top-down proteomic sample analyses. This approach was implemented for two PBP2a variants, PBP2amecA and PBP2amecC, and was accurate across a representative panel of MRSA strains with different genetic backgrounds. Additionally, PBP2amecA was successfully detected from clinical isolates using a five-minute liquid chromatographic separation and implementation of this MS detection strategy. Our results highlight the capability of direct MS-based resistance marker detection and potential advantages for implementing these approaches in clinical diagnostics.
Collapse
|
9
|
Tsuchida S, Umemura H, Nakayama T. Current Status of Matrix-Assisted Laser Desorption/Ionization-Time-of-Flight Mass Spectrometry (MALDI-TOF MS) in Clinical Diagnostic Microbiology. Molecules 2020; 25:molecules25204775. [PMID: 33080897 PMCID: PMC7587594 DOI: 10.3390/molecules25204775] [Citation(s) in RCA: 81] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 10/15/2020] [Accepted: 10/15/2020] [Indexed: 12/28/2022] Open
Abstract
Mass spectrometry (MS), a core technology for proteomics and metabolomics, is currently being developed for clinical applications. The identification of microorganisms in clinical samples using matrix-assisted laser desorption/ionization–time-of-flight mass spectrometry (MALDI-TOF MS) is a representative MS-based proteomics application that is relevant to daily clinical practice. This technology has the advantages of convenience, speed, and accuracy when compared with conventional biochemical methods. MALDI-TOF MS can shorten the time used for microbial identification by about 1 day in routine workflows. Sample preparation from microbial colonies has been improved, increasing the accuracy and speed of identification. MALDI-TOF MS is also used for testing blood, cerebrospinal fluid, and urine, because it can directly identify the microorganisms in these liquid samples without prior culture or subculture. Thus, MALDI-TOF MS has the potential to improve patient prognosis and decrease the length of hospitalization and is therefore currently considered an essential tool in clinical microbiology. Furthermore, MALDI-TOF MS is currently being combined with other technologies, such as flow cytometry, to expand the scope of clinical applications.
Collapse
|