High-Throughput, Fluorescence-Based Esterase Activity Assay for Assessing Polysorbate Degradation Risk during Biopharmaceutical Development.
Pharm Res 2021;
38:397-413. [PMID:
33655394 DOI:
10.1007/s11095-021-03011-1]
[Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 02/04/2021] [Indexed: 10/22/2022]
Abstract
PURPOSE
Hydrolytic degradation of polysorbate during 2-8°C storage of monoclonal antibody drug products has been attributed to residual enzymes (e.g., esterases) from bioprocessing steps. Robust detection of esterase activity using sensitive, non-polysorbate surrogate substrates can provide an alternate method to assess polysorbate degradation risk, if the correlation between the esterase activity and polysorbate degradation is established.
METHODS
A general esterase activity assay was developed as a monitoring and characterization tool during bioprocess development of monoclonal antibodies.
RESULTS
We report a fluorescence plate-based assay for quantifying esterase activity, utilizing 4-methylumbelliferyl caprylate (MU-C8) as the esterase substrate. The assay was first assessed for substrate, inhibitor and pH specificity using both model enzymes and purified protein samples. The assay was then extensively tested to understand sample matrix effects on activity rates.
CONCLUSIONS
The use of this high-throughput method will allow for rapid characterization of protein samples in under three hours. The esterase activity correlated directly with polysorbate degradation and can provide valuable information on polysorbate degradation risk throughout drug development.