1
|
Chen HC, Hu PC, Yao JT, Ye SJ, Ma Q. Male sling versus artificial urinary sphincter for the treatment of incontinence after prostate surgery: a systematic review with meta-analysis. Transl Androl Urol 2024; 13:1416-1424. [PMID: 39280681 PMCID: PMC11399032 DOI: 10.21037/tau-24-107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Accepted: 07/28/2024] [Indexed: 09/18/2024] Open
Abstract
Background Urinary incontinence following prostate treatment (IPT) represents a significant complication that detrimentally impacts the quality of life for patients who have undergone prostate surgery. Presently, there is a scarcity of evidence regarding the preferred surgical techniques for IPT. We conducted a meta-analysis to compare the outcomes of the male sling and artificial urinary sphincter (AUS) in the treatment of IPT. Methods Data were extracted through electronic literature searches on PubMed, Web of Science, and Embase databases until September 2023. Eligible studies included patients who underwent AUS or male sling procedures for IPT and had a follow-up duration exceeding 12 months. The primary end point was the success rate, with the secondary outcome focusing on complication rates. A fixed-effects or random-effects models were used to calculate the pooled estimate and its 95% confidence interval (CI). The publication bias was assessed using funnel plots and Egger's regression test. Results The meta-analysis included nine studies, involving a total of 1,350 participants. No statistically significant difference in success rates was found between AUS and male sling [odds ratio (OR): 0.96, 95% CI: 0.91-1.01]. In terms of the complication rate, there was no significant disparity between the two procedures (OR: 0.87, 95% CI: 0.86-1.12). Conclusions The findings from this study indicated that male sling surgery yielded success and complication rates comparable to those of AUS. This suggests that male sling could serve as a viable alternative surgical option in the treatment of IPT.
Collapse
Affiliation(s)
- Hai-Chao Chen
- Department of Urology, The First Affiliated Hospital of Ningbo University, Ningbo, China
| | - Peng-Cheng Hu
- Health Science Center, Ningbo University, Ningbo, China
| | - Jia-Tao Yao
- Health Science Center, Ningbo University, Ningbo, China
| | - Shi-Jie Ye
- Health Science Center, Ningbo University, Ningbo, China
| | - Qi Ma
- Comprehensive Genitourinary Cancer Center, The First Affiliated Hospital of Ningbo University, Ningbo, China
- Yi-Huan Genitourinary Cancer Group, Ningbo, China
| |
Collapse
|
2
|
Madanelo M, Chartier-Kastler E, Greenwell T, Gray G, Khavari R, Van Koeveringe GA, Van Der Aa F, Peyronnet B. Artificial urinary sphincter and female stress urinary incontinence over the past 50 years: a narrative review. Transl Androl Urol 2024; 13:1674-1686. [PMID: 39280667 PMCID: PMC11399035 DOI: 10.21037/tau-23-58] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2023] [Accepted: 10/07/2023] [Indexed: 09/18/2024] Open
Abstract
Background and Objective The aim of the present report was to provide an overview of the use of the artificial urinary sphincter (AUS) in adult females with stress urinary incontinence (SUI) over the past 50 years. Methods A literature search was conducted in December 2022 and January 2023 using the MEDLINE and Embase databases, screening for randomized controlled trials (RCTs), prospective and retrospective series and reviews on AUS. Only articles published in English or French were included. The search strategy involved a free text protocol and the narrative review reporting checklist was completed. Key Content and Findings The AUS is a device used over the past 50 years for SUI caused by intrinsic sphincter deficiency (ISD). It has the theoretical ability to simulate the function of a biological urinary sphincter. Although the role of the AUS for females with ISD remains heterogeneous from one part of the world to the other, the existing literature demonstrates that AUS yields satisfactory functional outcomes in female SUI patients, comparable or better to what has been reported in male AUS series. Hence, the main barrier to its adoption has so far been the technical challenge of its implantation at the bladder neck. Regarding the results of AUS implantation in females, we included in this review 3 reviews, retrospective studies and 1 prospective study. In recent years, robotic techniques of female AUS implantation have spread significantly with promising outcomes including numerous reports suggesting that it may decrease its morbidity. In the near future, the development of electromechanical devices may further expand the role of AUS in the management of female SUI. Conclusions While the use of AUS in female patients provides excellent functional outcomes, it has been limited to scarce centers. However, due to the rise of minimally invasive approaches, it has started spreading again over the past few years. The future of AUS is likely to be bright, fed by technological advances of the device and robotic surgical system, high level of evidence studies and joint efforts of the urological community to facilitate its diffusion across the world.
Collapse
Affiliation(s)
- Mariana Madanelo
- Department of Urology, Centro Hospitalar Universitário de Santo António, Porto, Portugal
| | - Emmanuel Chartier-Kastler
- Department of Urology, Pitié-Salpêtrière University Hospital, Paris Sorbonne University, Paris, France
| | - Tamsin Greenwell
- Department of Urology, University College London Hospital, London, UK
| | - Gary Gray
- Department of Urology, University of Alberta, Edmonton, Canada
| | - Rose Khavari
- Department of Urology, Houston Methodist Hospital, Houston, USA
| | | | | | | |
Collapse
|
3
|
Téllez C, Diego R, Szczesniewski J, Giammò A, González-Enguita C, Schönburg S, Queissert F, Romero A, Gonsior A, Martins FE, Cruz F, Rourke K, Angulo JC. Results of Adjustable Trans-Obturator Male System for Stress Urinary Incontinence after Transurethral Resection or Holmium Laser Enucleation of the Prostate: International Multicenter Study. J Clin Med 2024; 13:4628. [PMID: 39200769 PMCID: PMC11354669 DOI: 10.3390/jcm13164628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2024] [Revised: 07/31/2024] [Accepted: 08/06/2024] [Indexed: 09/02/2024] Open
Abstract
Background: Male stress urinary incontinence (SUI) after surgical treatment of benign prostatic enlargement (BPE) is an infrequent but dreadful complication and constitutes a therapeutic challenge. The efficacy and safety of the adjustable trans-obturator male system (ATOMS®) in these patients is rather unknown, mainly due to the rarity of this condition. We aimed to assess the results of ATOMS to treat SUI after transurethral resection (TURP) or holmium laser enucleation (HoLEP) of the prostate. Methods: Retrospective multicenter study evaluating patients with SUI after TURP or HoLEP for BPE primarily treated with silicone-covered scrotal port (SSP) ATOMS implants in ten different institutions in Europe and Canada between 2018 and 2022. Inclusion criteria were pure SUI for >1 year after endoscopic treatment for BPE and informed consent to receive an ATOMS. The primary endpoint of the study was a dry rate (pad test ≤ 20 mL/day after adjustment). The secondary endpoints were: the total continence rate (no pads and no leakage), complication rate (Clavien-Dindo classification) and self-perceived satisfaction (Patient Global Impression of Improvement (PGI-I) scale 1 to 3). Descriptive analytics, Wilcoxon's rank sum test and Fisher's exact test were performed. Results: A total of 40 consecutive patients fulfilled the inclusion criteria, 23 following TURP and 17 HoLEP. After ATOMS adjustment, 32 (80%) patients were dry (78.3% TURP and 82.4% HoLEP; p = 1) and total continence was achieved in 18 (45%) patients (43.5% TURP and 47% HoLEP; p = 0.82). The median pad test was at a 500 (IQR 300) mL baseline (648 (IQR 650) TURP and 500 (IQR 340) HoLEP; p = 0.62) and 20 (IQR 89) mL (40 (IQR 90) RTUP and 10 (IQR 89) HoLEP; p = 0.56) after adjustment. Satisfaction (PGI-I ≤ 3) was reported in 37 (92.5%) patients (95.6% TURP and 88.2% HoLEP; p = 0.5). There were no significant differences between patients treated with TURP or HoLEP regarding the patient age, radiotherapy and number of adjustments needed. After 32.5 (IQR 30.5) months, median follow-up postoperative complications occurred in seven (17.5%) cases (two grade I and five grade II; three after TURP and four HoLEP) and two devices were removed (5%, both HoLEP). Conclusions: ATOMS is an efficacious and safe alternative to treat SUI due to sphincteric damage produced by endoscopic surgery for BPE, both TURP and HoLEP. Future studies with a larger number of patients may identify predictive factors that would allow better patient selection for ATOMS in this scenario.
Collapse
Affiliation(s)
- Carlos Téllez
- Clinical Department, Faculty of Biomedical Science, Universidad Europea, Carretera de Toledo, Km 12,500, Getafe, 28905 Madrid, Spain; (C.T.); (R.D.)
- Department of Urology, Hospital Universitario de Getafe, Carretera de Toledo, Km 12,500, Getafe, 28905 Madrid, Spain;
| | - Rodrigo Diego
- Clinical Department, Faculty of Biomedical Science, Universidad Europea, Carretera de Toledo, Km 12,500, Getafe, 28905 Madrid, Spain; (C.T.); (R.D.)
| | - Juliusz Szczesniewski
- Department of Urology, Hospital Universitario de Getafe, Carretera de Toledo, Km 12,500, Getafe, 28905 Madrid, Spain;
| | - Alessandro Giammò
- Department of Neuro-Urology, CTO/Spinal Cord Unit, AOU Città della Salute e della Scienza di Torino, Via Zuretti 24, 10126 Torino, Italy;
| | - Carmen González-Enguita
- Department of Urology, Hospital Fundación Jiménez Díaz, Av. de los Reyes Católicos, 2, 28040 Madrid, Spain;
| | - Sandra Schönburg
- Department of Neuo-Urology, BG Klinikum Bergmannstrost Halle, Merseburger Str. 165, 06112 Halle (Saale), Germany
- Department of Urology and Kidney Transplantation, Martin Luther University, Ernst-Grube-Straße 40, 06120 Halle (Saale), Germany
| | - Fabian Queissert
- Department of Urology and Pediatric Urology, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48149 Münster, Germany;
| | - Antonio Romero
- Department of Urology, Hospital Universitario Morales Meseguer, Avd. Marqués de los Vélez s/n, 30008 Murcia, Spain;
| | - Andreas Gonsior
- Klinik und Poliklinik für Urologie, University of Leipzig, Liebigstraße 20, 04103 Leipzig, Germany;
| | - Francisco E. Martins
- Department of Urology, Centro Hospitalar Universitário de Lisboa Norte, Hospital Santa María, Av. Prof. Egas Moniz MB, 1649-028 Lisboa, Portugal;
| | - Francisco Cruz
- Department of Urology, Centro Hospitalar São João, Alameda Prof. Hernâni Monteiro, 4200-319 Porto, Portugal;
- I3S Institute, Faculty of Medicine of Porto, R. Alfredo Allen 208, 4200-135 Porto, Portugal
| | - Keith Rourke
- Department of Urology, Alberta University, Hospital Edmonton, 8440 112 St NW, Edmonton, AB T6G 2B7, Canada;
| | - Javier C. Angulo
- Clinical Department, Faculty of Biomedical Science, Universidad Europea, Carretera de Toledo, Km 12,500, Getafe, 28905 Madrid, Spain; (C.T.); (R.D.)
- Department of Urology, Hospital Universitario de Getafe, Carretera de Toledo, Km 12,500, Getafe, 28905 Madrid, Spain;
| |
Collapse
|
4
|
Angulo JC. Complications of Prostate Cancer Treatment: Open Issues. J Clin Med 2024; 13:3090. [PMID: 38892801 PMCID: PMC11173163 DOI: 10.3390/jcm13113090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Accepted: 05/13/2024] [Indexed: 06/21/2024] Open
Abstract
Unfortunately, prostate cancer treatment is not free of complications [...].
Collapse
Affiliation(s)
- Javier C. Angulo
- Clinical Department, Faculty of Biomedical Science, Universidad Europea, Carretera de Toledo, Km 12.500, Getafe, 28905 Madrid, Spain; ; Tel.: +34-699497569
- Department of Urology, Hospital Universitario de Getafe, Carretera de Toledo, Km 12.500, Getafe, 28905 Madrid, Spain
| |
Collapse
|
5
|
Angulo JC, Giammò A, Queissert F, Schönburg S, González‐Enguita C, Gonsior A, Romero A, Martins FE, Antunes‐Lopes T, González R, Szczesniewski J, Téllez C, Cruz F, Rourke KF. The effectiveness of adjustable trans-obturator male system (ATOMS) in radiated patients is reduced: A propensity score-matched analysis. BJUI COMPASS 2024; 5:506-514. [PMID: 38633825 PMCID: PMC11019248 DOI: 10.1002/bco2.329] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 11/24/2023] [Accepted: 12/21/2023] [Indexed: 04/19/2024] Open
Abstract
Objectives This study aimed to compare the effectiveness and safety of the adjustable trans-obturator male system (ATOMS®) to treat post-prostatectomy incontinence (PPI) in radiated patients compared with non-radiated patients, using propensity score-matching analysis to enhance the validity of the comparison. Patients and methods Consecutive men with PPI treated with silicone-covered scrotal port ATOMS (A.M.I., Feldkirch, Austria) in nine different institutions between 2016 and 2022 were included. Preoperative assessment evaluated 24-h pad usage, urethroscopy and urodynamics, if indicated. Propensity score-matching analysis was based on age, length of follow-up, previous PPI treatment, previous bladder neck stricture, androgen deprivation and pad usage. The primary endpoint was dry rate, defined as no pads post-operatively with a security pad allowed. The secondary endpoints were complications, device removal and self-perceived satisfaction with the Patient Global Impression of Improvement (PGI-I) scale. Results Of the 710 included patients, 342 were matched, and the study groups were balanced for the baseline matched variables. The mean baseline 24-h pad was 4.8 in both groups (p = 0.48). The mean follow-up was 27.5 ± 18.6 months, which was also equivalent between groups (p = 0.36). The primary outcome was achieved in 73 (42.7%) radiated patients and in 115 (67.3%) non-radiated patients (p < 0.0001). The mean pad count at the last follow-up was 1.5 and 0.8, respectively (p < 0.0001). There was no significant difference in complications (p = 0.94), but surgical revision and device explant rates were higher (p = 0.03 and p = 0.01, respectively), and the proportion of patients highly satisfied (PGI-I = 1) was lower in the radiated group (p = 0.01). At sensitivity analysis, the study was found to be reasonably robust to hidden bias. Conclusion ATOMS implantation significantly outperformed in patients without adjuvant radiation over radiated patients.
Collapse
Affiliation(s)
- Javier C. Angulo
- Clinical Department, Faculty of Biomedical ScienceUniversidad EuropeaMadridSpain
- Department of UrologyHospital Universitario de GetafeMadridSpain
| | - Alessandro Giammò
- Department of Neuro‐Urology, CTO/Spinal Cord UnitAOU Città della Salute e della Scienza di TorinoTurinItaly
| | - Fabian Queissert
- Department of Urology and Pediatric UrologyUniversity Hospital MuensterMünsterGermany
| | - Sandra Schönburg
- Department of Urology and Kidney TransplantationMartin Luther UniversityHalle (Saale)Germany
| | | | - Andreas Gonsior
- Klinik und Poliklinik für UrologieUniversity of LeipzigLeipzigGermany
| | - Antonio Romero
- Department of UrologyHospital Universitario Morales MeseguerMurciaSpain
| | - Francisco E. Martins
- Department of UrologyCentro Hospitalar Universitário de Lisboa Norte, Hospital Santa MaríaLisbonPortugal
| | - Tiago Antunes‐Lopes
- Department of UrologyCentro Hospitalar São JoãoPortoPortugal
- Faculty of Medicine of PortoI3S InstitutePortoPortugal
| | - Raquel González
- Department of UrologyHospital Fundación Jiménez DíazMadridSpain
| | | | - Carlos Téllez
- Clinical Department, Faculty of Biomedical ScienceUniversidad EuropeaMadridSpain
- Department of UrologyHospital Universitario de GetafeMadridSpain
| | - Francisco Cruz
- Department of UrologyCentro Hospitalar São JoãoPortoPortugal
- Faculty of Medicine of PortoI3S InstitutePortoPortugal
| | - Keith F. Rourke
- Department of UrologyAlberta University, Hospital EdmontonEdmontonAlbertaCanada
| |
Collapse
|
6
|
Roth I, Juliebø-Jones P, Arvei Moen C, Beisland C, Hjelle KM. Outcomes with the Adjustable Transobturator Male System (ATOMS) for the Treatment of Male Stress Urinary Incontinence After Prostate Surgery and the Impact of Previous Radiotherapy. EUR UROL SUPPL 2024; 62:68-73. [PMID: 38468862 PMCID: PMC10925931 DOI: 10.1016/j.euros.2024.02.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/22/2024] [Indexed: 03/13/2024] Open
Abstract
Background and objective The adjustable transobturator male system (ATOMS) is an established treatment for patients with urinary incontinence after prostate surgery. Our objective was to evaluate the efficacy and the complication burdens associated with ATOMS with a focus on exploring the potential impact on previous radiotherapy (RT). Methods We performed a retrospective analysis for consecutive patients who underwent ATMOS implantation procedure at a tertiary center over an 11-yr study period. Outcomes of interest were dryness at 3-mo follow up, postoperative complications (≤30 d), and late treatment failures (>30 d). Key findings and limitations A total of 118 patients underwent ATOMS surgery performed by five different surgeons. Median follow-up was 67 mo (interquartile range 41-95). The mean 24-h pad count after surgery was 1.1 (range 0-8) and the mean reduction in pad weight was 179 g (range 0-1080). There was no significant difference in the reduction in pad use between groups with and without RT (-1.7 vs -2.4; p = 0.13). Multivariable analysis revealed that RT, degree of incontinence, and age were not risk factors for reoperation. Conclusions and clinical implications ATOMS implantation is feasible in patients who have undergone prostate RT and patients with severe stress urinary incontinence after prostate surgery. We found that RT was not a risk factor for reoperation and there was no significant difference in pad weight reduction by RT status. This study offers new insight into potential incontinence surgery for male patients with stress urinary incontinence and previous RT. Patient summary We assessed outcomes for patients who had an ATOMS (adjustable transobturator male system) device implanted to control stress urinary incontinence after prostate surgery. After implantation, 52.5% of the patients reported zero leakage and 39.9% reported only mild incontinence. Our results show that this device can improve continence after prostate surgery and is also suitable in patients who underwent radiotherapy.
Collapse
Affiliation(s)
- Ingunn Roth
- Department of Urology, Haukeland University Hospital, Bergen, Norway
| | - Patrick Juliebø-Jones
- Department of Urology, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Christian Arvei Moen
- Department of Urology, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Christian Beisland
- Department of Urology, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Karin M. Hjelle
- Department of Urology, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Bergen, Norway
| |
Collapse
|
7
|
Virseda-Chamorro M, Téllez C, Salinas-Casado J, Szczesniewski J, Ruiz-Grana S, Arance I, Angulo JC. Factors Influencing Postoperative Overactive Bladder after Adjustable Trans-Obturator Male System Implantation for Male Stress Incontinence following Prostatectomy. J Clin Med 2023; 12:7505. [PMID: 38137573 PMCID: PMC10744244 DOI: 10.3390/jcm12247505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 12/01/2023] [Accepted: 12/03/2023] [Indexed: 12/24/2023] Open
Abstract
We aimed to determine the risk factors for postoperative overactive bladder (OAB) in patients treated with an adjustable trans-obturator male system (ATOMS) for stress incontinence after radical treatment of prostate cancer. A prospective study was performed on 56 patients implanted with an ATOMS for PPI. Clinical and urodynamic information was recorded before and after ATOMS implantation. We built a multivariate model to find out the clinical and urodynamic factors that independently influenced postoperative OAB and the prognostic factors that influenced the efficacy of medical treatment of OAB. We found that the clinical risk factors were the preoperative intensity of urinary incontinence (number of daily pads used and amount of urinary leakage), International Consultation on Incontinence Questionnaire (ICIQ) score, postoperative number of ATOMS adjustments, final cushion volume, and incontinence cure. The urodynamic data associated with OAB were cystometric bladder capacity, voided volume, volume at initial involuntary contraction (IC), maximum flow rate, bladder contractility index (BCI), and urethral resistance (URA). The prognostic factors for the efficacy of oral treatment of OAB were the volume at the first IC (direct relationship) and the maximum abdominal voiding pressure (inverse relationship). The multivariate model showed that the independent clinical risk factors were the daily pad count before the implantation and the ICIQ score at baseline and after treatment. The independent urodynamic data were the volume at the first IC (inverse relationship) and the URA value (direct relationship). Both predictive factors of treatment efficacy were found to be independent. Detrusor overactivity plays an important role in postoperative OAB, although other urodynamic and clinical factors such as the degree of urethral resistance and abdominal strength may influence this condition.
Collapse
Affiliation(s)
| | - Carlos Téllez
- Urology Department, Hospital Universitario de Getafe, 28905 Getafe, Spain; (C.T.); (J.S.); (S.R.-G.); (I.A.)
- Clinical Department, Faculty of Medical Sciences, Universidad Europea, 28670 Madrid, Spain
| | - Jesus Salinas-Casado
- Urology Department, Hospital Clínico de San Carlos, 28040 Madrid, Spain;
- Department of Surgery, Faculty of Medicine, Universidad Complutense, 28040 Madrid, Spain
| | - Juliusz Szczesniewski
- Urology Department, Hospital Universitario de Getafe, 28905 Getafe, Spain; (C.T.); (J.S.); (S.R.-G.); (I.A.)
| | - Sonia Ruiz-Grana
- Urology Department, Hospital Universitario de Getafe, 28905 Getafe, Spain; (C.T.); (J.S.); (S.R.-G.); (I.A.)
| | - Ignacio Arance
- Urology Department, Hospital Universitario de Getafe, 28905 Getafe, Spain; (C.T.); (J.S.); (S.R.-G.); (I.A.)
- Clinical Department, Faculty of Medical Sciences, Universidad Europea, 28670 Madrid, Spain
| | - Javier C. Angulo
- Urology Department, Hospital Universitario de Getafe, 28905 Getafe, Spain; (C.T.); (J.S.); (S.R.-G.); (I.A.)
- Clinical Department, Faculty of Medical Sciences, Universidad Europea, 28670 Madrid, Spain
| |
Collapse
|
8
|
Geretto P, De Nunzio C, Li Marzi V, Lombardo R. Surgical treatment of male stress urinary incontinence: a knot still to be unravelled. Transl Androl Urol 2023; 12:1614-1616. [PMID: 37969771 PMCID: PMC10643394 DOI: 10.21037/tau-23-446] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 10/10/2023] [Indexed: 11/17/2023] Open
Affiliation(s)
- Paolo Geretto
- Unit of Neuro-Urology, Città della Salute e della Scienza University Hospital, University of Turin, Turin, Italy
| | - Cosimo De Nunzio
- Unit of Urology, Sant’Andrea Hospital, Sapienza University, Rome, Italy
| | - Vincenzo Li Marzi
- Department of Minimally Invasive and Robotic Urologic Surgery, Careggi University Hospital, University of Florence, Florence, Italy
| | - Riccardo Lombardo
- Unit of Urology, Sant’Andrea Hospital, Sapienza University, Rome, Italy
| |
Collapse
|
9
|
Geretto P, Ammirati E, Falcone M, Manassero A, Agnello M, Della Corte M, Gontero P, Giammò A. Comparison Study between Artificial Urinary Sphincter and Adjustable Male Sling: A Propensity-Score-Matched Analysis. J Clin Med 2023; 12:5489. [PMID: 37685552 PMCID: PMC10487594 DOI: 10.3390/jcm12175489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 08/09/2023] [Accepted: 08/17/2023] [Indexed: 09/10/2023] Open
Abstract
AIMS This study aimed to compare the outcomes of the AUS and an adjustable male sling (ATOMSTM). METHODS It was a retrospective observational cohort study with two arms. Propensity score matching (PSM) was performed in order to limit selection bias and, consequently, a comparison between groups in terms of functional outcomes (24 h pad test and perception of improvement questionnaires), complications (overall complications, high-grade complications, reinterventions and explantations) and device survival was performed. RESULTS 49 patients in both arms were included. The baseline characteristics were similar between the groups. The mean follow up was 43 ± 35 months. Dryness was achieved in 22 patients (44.9%) in the AUS group and 11 (22.5%) in the sling group (p = 0.03). A total of 40 patients declared themselves well improved in the sling group (81%), while 35 (71%) declared the same in the AUS group (p = 0.78). The AUS was associated with more high-grade complications, reinterventions and explantations than the ATOMSTM. Survival at 60 months was 82 ± 9% in the sling group and 67 ± 7% in the AUS group (p = 0.03). CONCLUSIONS While the AUS may be characterized by a higher dry rate, it has an increased risk of high-grade complications and reinterventions. It is proposed that the ATOMS prosthesis can be successfully used for patients who require a less invasive procedure that maintains good functional outcomes.
Collapse
Affiliation(s)
- Paolo Geretto
- Division of Neuro-Urology, Department of Surgical Sciences, Città della Salute e della Scienza Hospital, University of Turin, 10126 Turin, Italy (A.M.)
| | - Enrico Ammirati
- Division of Neuro-Urology, Department of Surgical Sciences, Città della Salute e della Scienza Hospital, University of Turin, 10126 Turin, Italy (A.M.)
| | - Marco Falcone
- Division of Neuro-Urology, Department of Surgical Sciences, Città della Salute e della Scienza Hospital, University of Turin, 10126 Turin, Italy (A.M.)
- Urology Clinic-A.O.U. “Città della Salute e della Scienza”-Molinette Hospital, University of Turin, 10100 Turin, Italy;
| | - Alberto Manassero
- Division of Neuro-Urology, Department of Surgical Sciences, Città della Salute e della Scienza Hospital, University of Turin, 10126 Turin, Italy (A.M.)
| | - Marco Agnello
- Division of Neuro-Urology, Department of Surgical Sciences, Città della Salute e della Scienza Hospital, University of Turin, 10126 Turin, Italy (A.M.)
| | - Marcello Della Corte
- Division of Neuro-Urology, Department of Surgical Sciences, Città della Salute e della Scienza Hospital, University of Turin, 10126 Turin, Italy (A.M.)
- Division of Urology, Department of Oncology, San Luigi Gonzaga Hospital, University of Turin, Regione Gonzole 10, 10043 Orbassano, Italy
| | - Paolo Gontero
- Urology Clinic-A.O.U. “Città della Salute e della Scienza”-Molinette Hospital, University of Turin, 10100 Turin, Italy;
| | - Alessandro Giammò
- Division of Neuro-Urology, Department of Surgical Sciences, Città della Salute e della Scienza Hospital, University of Turin, 10126 Turin, Italy (A.M.)
| |
Collapse
|
10
|
Téllez C, Szczesniewski J, Virseda-Chamorro M, Arance I, Angulo JC. Update on Adjustable Trans-Obturator Male System (ATOMS) for Male Incontinence after Prostate Cancer Surgery. Curr Oncol 2023; 30:4153-4165. [PMID: 37185429 PMCID: PMC10136884 DOI: 10.3390/curroncol30040316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 04/03/2023] [Accepted: 04/10/2023] [Indexed: 05/17/2023] Open
Abstract
(1) Background: The adjustable trans-obturator male system (ATOMS) is a surgical device developed to treat post-prostatectomy incontinence (PPI) after prostate cancer treatment. We review the current literature on this anti-incontinence device with the intention of assessing the effectiveness, safety and duration of the silicone-covered scrotal port (SSP) ATOMS, the only generation of the device that is currently available. (2) Material and Methods: Non-systematic literature review is performed. Forty-eight full-text articles are assessed for eligibility. Case reports, expert opinions or commentaries without specific data reported (n = 6), studies with patients who underwent intervention before 2014 (IP or SP ATOMS; n = 10), and studies with incontinence after transurethral resection of the prostate (TUR-P; n = 2) are excluded for analysis. Thirty studies with SSP ATOMS are included in a qualitative synthesis that incorporates systematic reviews (n = 3), articles partially overlapping with other previously published studies (e.g., follow-up or series updates; n = 9), and studies focusing on specific populations (n = 8). Only articles revealing outcomes of SSP ATOMS were included in the quantitative synthesis of results (n = 10). (3) Results: the pooled data of 1515 patients from the 10 studies with SSP ATOMS confirmed very satisfactory results with this device after adjustment: dry rate: 63-82%, improved rate: 85-100%, complication rate: 7-33%, device infection rate: 2.7-6.2% and explant rate: 0-19%. The durability of the device is reassuring, with 89% of devices in place 5 years after implantation. (4) Conclusion: Despite the absence of randomized controlled studies, the literature findings confirm results of SSP ATOMS appear equivalent to those of artificial urinary sphincters (AUSs) in terms of continence, satisfaction and complications, but with a lower rate of revision in the long-term. A prospective study identified that patients with daily pad test results <900 mL and a Male Stress Incontinence Grading Scale (MSIGS) of not 4 (i.e., early and persistent stream or urine loss) are the best candidates. Future studies centered on the elder population at higher risk of impaired cognitive ability and in patients including radiation as prostate cancer treatment are needed.
Collapse
Affiliation(s)
- Carlos Téllez
- Clinical Department, Faculty of Biomedical Sciences, Universidad Europea, 28805 Madrid, Spain
- Urology Department, Hospital Universitario de Getafe, 28805 Madrid, Spain
| | - Juliusz Szczesniewski
- Clinical Department, Faculty of Biomedical Sciences, Universidad Europea, 28805 Madrid, Spain
- Urology Department, Hospital Universitario de Getafe, 28805 Madrid, Spain
| | - Miguel Virseda-Chamorro
- Urology Department, Hospital Nacional de Parapléjicos, Carretera de la Peraleda, S/N, 45004 Toledo, Spain
| | - Ignacio Arance
- Clinical Department, Faculty of Biomedical Sciences, Universidad Europea, 28805 Madrid, Spain
- Urology Department, Hospital Universitario de Getafe, 28805 Madrid, Spain
| | - Javier C Angulo
- Clinical Department, Faculty of Biomedical Sciences, Universidad Europea, 28805 Madrid, Spain
- Urology Department, Hospital Universitario de Getafe, 28805 Madrid, Spain
| |
Collapse
|
11
|
ATOMS (Adjustable Trans-Obturator Male System) in Patients with Post-Prostatectomy Incontinence and Previously Treated Urethral Stricture or Bladder Neck Contracture. J Clin Med 2022; 11:jcm11164882. [PMID: 36013121 PMCID: PMC9410097 DOI: 10.3390/jcm11164882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Revised: 08/09/2022] [Accepted: 08/16/2022] [Indexed: 11/22/2022] Open
Abstract
(1) Background: Male stress incontinence in patients with previously treated urethral or bladder neck stricture is a therapeutic challenge. The efficacy and safety of the adjustable trans-obturator male system (ATOMS) in these patients is unknown. (2) Methods: All patients with primary ATOMS implants in our institution between 2014 and 2021 were included. The outcomes of patients with previously treated urethral or bladder neck stricture (≥6 months before ATOMS implant) and stable 16Ch urethral caliber were compared to those without a history of stricture. The primary endpoint was the dry patient rate, defined as the pad test ≤ 20 mL/day, and complication rate, including device removal. The secondary variable was self-perceived satisfaction using the Patient Global Impression of Improvement (PGI-I) scale. Wilcoxon rank sum test, Fisher’s exact test and logistic regression were performed. (3) Results: One hundred and forty-nine consecutive patients were included, twenty-one (14%) previously treated for urethral or bladder neck stricture (seven urethroplasty, nine internal urethrotomy and five bladder neck incision). After ATOMS adjustment, 38% of the patients with treated stricture were continent compared to 83% of those without (p < 0.0001). After weighted matched observations using propensity score pairing, the proportion of continent patients without a previous stricture was 56% (p = 0.236). Complications occurred in 29% of the patients with stricture and in 20% of those without (p = 0.34). The severity of the complications was distributed evenly among the groups (p = 0.42). Regarding self-perceived satisfaction with the implant, 90% of the patients with stricture perceived the results satisfactorily (PGI-I 1−3) compared to 97% of the rest (p = 0.167). Stricture was associated with radiotherapy (p < 0.0001) and time from prostatectomy to implantation (p = 0.012). There was a moderate correlation between previous stricture and the severity of incontinence, both evaluated according to the 24-h pad test (Rho = 0.378; p < 0.0001) and the ICIQ-SF questionnaire (Rho = 0.351; p < 0.0001). Multivariate analysis for the factors predictive of failure after ATOMS adjustment revealed previous stricture (OR 4.66; 95% CI 1.2−18.87), baseline 24-h pad test (per 100 mL, OR 1.28; 95% CI 1.09−1.52) and final cushion volume (per mL, OR 1.34; 95% CI 1.19−1.55). This model predicted dryness with an AUC of 92%. After the PSMATCH procedure using a propensity score, the model remained unchanged, with the previous stricture (OR 8.05; 95% CI 1.08−110.83), baseline 24-h pad test (per 100 mL, OR 1.53; 95% CI 1.15−2.26) and final cushion volume (per mL, OR 1.45; 95% CI 1.17−2) being independent predictors and an AUC of 93%. (4) Conclusions: ATOMS can be used to treat male stress incontinence in patients with a history of stricture, although the effectiveness of the device is reduced. On the other hand, the security and perceived satisfaction were equivalent for both groups.
Collapse
|
12
|
Refined Nomogram Incorporating Standing Cough Test Improves Prediction of Adjustable Trans-Obturator Male System (ATOMS) Success to Treat Post-Prostatectomy Male Stress Incontinence. J Pers Med 2022; 12:jpm12010094. [PMID: 35055409 PMCID: PMC8780728 DOI: 10.3390/jpm12010094] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 01/06/2022] [Accepted: 01/09/2022] [Indexed: 02/07/2023] Open
Abstract
(1) Background: The adjustable transobturator male system (ATOMS) device serves to treat post-prostatectomy incontinence, as it enhances residual urinary sphincteric function by dorsal compression of the bulbar urethra. We investigated the clinical parameters affecting continence recovery using this device and developed a decision aid to predict success. (2) Methods: We reviewed consecutive men treated with first-time ATOMS for post-prostatectomy incontinence from 2014 to 2021 at our institution. Patient demographics, reported pads per day (PPD), 24-h pad-test and Standing Cough Test (SCT), results’ grades 1–4, according to Male Stress Incontinence Grading Scale (MSIGS), and the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) questionnaire were assessed. Treatment success was defined as no pads or a single PPD with ≤20-mL 24-h pad-test. Logistic regression was performed using a stepwise model (entry 0.15 and stay criterium 0.1) to evaluate independent variables’ determinant of dryness. Receiver-operating characteristic (ROC) curves for predictive variables were evaluated and their area under curve (AUC) was compared. A nomogram was generated and internally validated to predict probability of treatment success. (3) Results: Overall, 149 men (median age 70 years, IQR 7) were evaluated with a median follow-up of 45 months (IQR 26). Twelve patients (8%) had previous devices for incontinence, and 21 (14.1%) had pelvic radiation. Thirty-five men (23.5%) did not achieve continence after ATOMS adjustment (use of no or one security PPD with ≤20-mL 24-h pad-test). In univariate analysis, Charlson comorbidity index (p = 0.0412), previous urethroplasty (p = 0.0187), baseline PPD (p < 0.0001), 24-h pad-test (p < 0.0001), MSIGS (p < 0.0001), and ICIQ-SF questionnaire score (p < 0.0001) predicted ATOMS failure. In a multivariable model, 24-h pad-test (p = 0.0031), MSIGS (p = 0.0244), and radiotherapy (p = 0.0216) were independent variables, with AUC 0.8221. The association of MSIGS and 24-h pad-test was the superior combination (AUC 0.8236). A nomogram to predict the probability of ATOMS failure using the independent variables identified was proposed. (4) Conclusions: Several variables were identified as predictive of success for ATOMS using clinical history, physical examination (MSIGS), and factors that evaluate urine loss severity (PPD, 24-h pad-test, and ICIQ-SF questionnaire). MSIGS adds prognostic value to 24-h pad-test in assessing success of ATOMS device to treat post-prostatectomy incontinence. A nomogram was proposed to calculate the risk of ATOMS failure, which could be of interest to personalize the decision to use this device or not in the individual patient.
Collapse
|
13
|
Adjustable Transobturator Male System (ATOMS) Infection: Causative Organisms and Clinical Profile. Urology 2021; 157:120-127. [PMID: 34425151 DOI: 10.1016/j.urology.2021.05.111] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 04/29/2021] [Accepted: 05/03/2021] [Indexed: 11/21/2022]
Abstract
OBJECTIVE To evaluate the clinical profile and the organisms producing adjustable transobturator male system (ATOMS) infection in a contemporary series. METHODS Multicenter retrospective study evaluating patients undergoing ATOMS explant for clinical signs of infection from a series of 902 patients treated in 9 academic institutions. Clinical and microbiological data were evaluated. RESULTS Infection presented in 24 patients (2.7%). The median age was 73 ± 7yrs and the median interval from ATOMS implantation to explant 11 ± 26.5mo. Infection was diagnosed within 3-months after surgery in 7(29.2%). Scrotal port erosion was present in 6 cases (25%) and systemic symptoms of parenchymatous testicular infection in 2(8.3%). The culture of the periprosthetic fluid was positive in 20(83.3%): 12(50%) Gram-negative bacteria, 9(37.5%) Gram-positive cocci and 1(4.2%) yeast. The most frequent isolates were Enterococcus and Proteus sp. (16.7% each), followed by Pseudomona sp. and S. epidermidis (12.5% each). Methicillin resistant S. aureus was detected only in 1 case (4.2%). Despite the infection 17 patients (70.8%) were satisfied with the implant and 18(75%) received a second device (11 repeated ATOMS and 7 AUS) at a median 9.7 ± 12.6mo after explant. Limitations include retrospective design and lack of microbiological cultures in ATOMS explanted for non-infective cause. CONCLUSION Infection of a prosthetic device is a disturbing complication. A proportion of patients with ATOMS infection is associated to scrotal port erosion and/or parenchymatous urinary tract infection. Enterococcus and Proteus sp. are the most common organisms producing ATOMS infection and this could have implications for the selection of the most appropriate surgical prophylaxis.
Collapse
|
14
|
Angulo JC, Schönburg S, Giammò A, Queissert F, Gonsior A, González-Enguita C, Martins FE, Rourke K, Cruz F. Artificial urinary sphincter or a second adjustable transobturator male system offer equivalent outcomes in patients whom required revision on the initial ATOMS device: An international multi-institutional experience. Neurourol Urodyn 2021; 40:897-909. [PMID: 33645867 DOI: 10.1002/nau.24646] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 02/05/2021] [Accepted: 02/14/2021] [Indexed: 11/11/2022]
Abstract
AIM To evaluate treatment options after surgical revision of adjustable transobturator male system (ATOMS) and the results of further incontinence implantation. MATERIALS AND METHODS A retrospective multicenter study evaluating patients with surgical revision of ATOMS in academic institutions. Causes and factors affecting revision-free interval were studied and also the frequency of device explant and placement of second ATOMS or artificial urinary sphincter (AUS) at surgeon discretion. Operative results, complications (Clavien-Dindo), and efficacy (postoperative pad-test, pad-count, patient satisfaction, and patient global impression of improvement [PGI-I scale]) of each treatment option were compared. RESULTS Seventy-eight out of 902 patients (8.65%) with ATOMS underwent surgical revision at 4.1 ± 2.4 years mean follow-up and 75 (8.3%) were explanted. The main causes for revision included persistence of incontinence (35.9%) and scrotal port erosion (34.6%). Independent risk factors of the shortened revision-free interval were previous anti-incontinence surgery (HR, 1.83; 95% CI, 1.06-3.16; p = 0.007) and port erosion (HR, 1.83; 95% CI, 1.06-3.16; p = 0.0027). Fifty-eight (6.4%) received a second implant: 31 repeated ATOMS and 27 AUS. Operative time was longer for AUS (p = .003). The visual analog scale of pain at hospital discharge (p = 0.837) and postoperative complications (p = 0.154) were equivalent. The predominant cuff size for AUS was 4.5 cm (59.3%). Mean follow-up after the second implant was 29.1 ± 25.8 months. Postoperative efficacy of secondary treatment results favored ATOMS based on pad-test (p = 0.016), pad-count (p = 0.029), patient satisfaction (p = 0.04), and PGI-I (p = 0.025). CONCLUSIONS ATOMS surgical revision due to different reasons generally leads to device explant. Rescue treatment is possible with ATOMS or AUS. No difference in postoperative complications was detected between secondary devices, but efficacy favors repeating ATOMS implantation.
Collapse
Affiliation(s)
- Javier C Angulo
- Clinical Department, Universidad Europea de Madrid, Hospital Universitario de Getafe, Madrid, Spain
| | - Sandra Schönburg
- Department of Urology and Kidney Transplantation, Martin Luther University, Halle (Saale), Germany
| | - Alessandro Giammò
- Department of Neuro-Urology, CTO/Spinal Cord Unit, AOU Città della Salute e della Scienza di Torino, Turin, Italy
| | - Fabian Queissert
- Department of Urology, Universitätsklinikum Münster, Münster, Germany
| | - Andreas Gonsior
- Klinik und Poliklinik für Urologie, University of Leipzig, Leipzig, Germany
| | | | - Francisco E Martins
- Centro Hospitalar Universitário de Lisboa Norte, Hospital Santa María, Lisboa, Portugal
| | - Keith Rourke
- Department of Urology, Alberta University, Edmonton, Alberta, Canada
| | - Francisco Cruz
- Department of Urology, Centro Hospitalar São João, Oporto, Portugal
| |
Collapse
|