1
|
Matsunari I. New Generation SPECT Cameras Based on Cadmium-Zinc Telluriide Technology. ANNALS OF NUCLEAR CARDIOLOGY 2024; 10:59-63. [PMID: 39635329 PMCID: PMC11612397 DOI: 10.17996/anc.24-00011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2024] [Revised: 10/11/2024] [Accepted: 10/11/2024] [Indexed: 12/07/2024]
Abstract
Despite recent developments in positron emission tomography technology, cardiac single photon emission computed tomography (SPECT) imaging continues to be the main stream of nuclear cardiology because of its high accessibility and wider clinical use. For SPECT imaging, cadmium-zinc telluride (CZT) based detectors have advantages over conventional Anger type detectors with more flexible camera design thanks to the small sized CZT detectors and high contrast imaging because of its high energy resolution. Approximately 15 years ago, CZT-based cardiac SPECT cameras became commercially available, resulting in great success in clinical practice. However, this was just the beginning of the CZT era. To date, CZT-based general purpose whole-body camera and 3 dimensional full-ring SPECT systems have been developed and become commercially available with promising initial results. Although there still are areas to be addressed before wider clinical use, the CZT-based technology may provide significant progresses in nuclear cardiology as new generation SPECT systems. Finally, newer materials for the semiconductor detectors are under investigation or development, suggesting that there will be more developments in cardiac SPECT technology.
Collapse
Affiliation(s)
- Ichiro Matsunari
- Division of Nuclear Medicine, Department of Radiology, Saitama Medical University Hospital, Saitama, Japan
| |
Collapse
|
2
|
Sweet C, Shmuel N, Shoaf JN, Stoecklein M, Muthukrishnan A, Stern E, Nguyen NC. A Pictorial Review of I-123 MIBG Imaging of Neuroblastoma Utilizing a State-of-the-Art CZT SPECT/CT System. Nucl Med Mol Imaging 2024; 58:1-8. [PMID: 38250182 PMCID: PMC10796310 DOI: 10.1007/s13139-023-00825-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 09/09/2023] [Accepted: 09/12/2023] [Indexed: 01/23/2024] Open
Abstract
The field of nuclear medicine is entering a new era of gamma-camera technology. Solid-state SPECT/CT systems will gradually replace the thallium-activated sodium-iodide NaI(Tl) systems. This digital technology allows drastic improvements in image quality, radiotracer dose reduction, and procedure efficiency. This pictorial review presents our initial experience on an NM/CT 870 CZT system (GE Healthcare), equipped with dual-head cadmium zinc telluride (CZT) detectors, for I-123 metaiodobenzylguanidine (MIBG) imaging in pediatric neuroblastoma. On planar imaging, CZT shows greater image quality than at conventional gamma-camera using the Infinia Hawkeye (GE Healthcare). Physiologic structures such as salivary glands and myocardium show sharper borders with a more notable signal-to-noise ratio at CZT than conventional gamma camera. On SPECT imaging, the CZT scanner, combined with resolution recovery, demonstrates either comparable or greater image quality at 80% of the conventional gamma camera’s acquisition time. Due to the 2.46-mm detector pixel with fully registered collimator holes matching each pixel and direct conversion of photons into electrical signals, the CZT gamma camera system provides significant advantages in photon localization and energy resolution.
Collapse
Affiliation(s)
- Cassidy Sweet
- Department of Radiology, UPMC Children’s Hospital of Pittsburgh, Pittsburgh, PA USA
| | | | - Jennifer N. Shoaf
- Department of Radiology, UPMC Children’s Hospital of Pittsburgh, Pittsburgh, PA USA
| | - Marcy Stoecklein
- Department of Radiology, UPMC Children’s Hospital of Pittsburgh, Pittsburgh, PA USA
| | | | | | - Nghi C. Nguyen
- Department of Radiology, University of Texas, Southwestern Medical Center, Dallas, TX USA
| |
Collapse
|
3
|
Ito T, Maeno T, Tsuchikame H, Shishido M, Nishi K, Kojima S, Hayashi T, Suzuki K. Adapting a low-count acquisition of the bone scintigraphy using deep denoising super-resolution convolutional neural network. Phys Med 2022; 100:18-25. [PMID: 35716484 DOI: 10.1016/j.ejmp.2022.06.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 04/21/2022] [Accepted: 06/11/2022] [Indexed: 10/18/2022] Open
Abstract
PURPOSE Deep-layer learning processing may improve contrast imaging with greater precision in low-count acquisition. However, no data on noise reduction using super-resolution processing for deep-layer learning have been reported in nuclear medicine imaging. OBJECTIVES This study was designed to evaluate the adaptability of deep denoising super-resolution convolutional neural networks (DDSRCNN) in nuclear medicine by comparing them with denoising convolutional natural networks (DnCNN), Gaussian processing, and nonlinear diffusion (NLD) processing. METHODS In this study, 156 patients were included. Data were collected using a matrix size of 256 × 256 with a pixel size of 2.46 mm at 0.898 folds, 15% energy window at the center of the photopeak energy (140 keV), and total count of 1000 kilocounts (kct). Following the training and validation of two learning models, we created 100 images for each 20-test datum. The peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) between each image and the reference image were calculated. RESULTS DDSRCNN showed the highest PSNR values for all total counts. Regarding SSIM, DDSRCNN had significantly higher values than the original and Gaussian. In DnCNN, false accumulation was observed as the total counts increased. Regarding PSNR and SSIM transition, the model using 100-500-kct training data was significantly higher than that using 100-kct training data. CONCLUSIONS Edge-preserving noise reduction processing was possible, and adaptability to low-count acquisition was demonstrated using DDSRCNN. Using training data with different noise levels, DDSRCNN could learn the noise components with high accuracy and contrast improvement.
Collapse
Affiliation(s)
- Toshimune Ito
- Department of Radiological, Technology, Faculty of Medical Technology, Teikyo University, 2-11-1 Kaga, Itabashi-ku, Tokyo 173-8605, Japan.
| | - Takafumi Maeno
- Department of Radiology, Saiseikai Yokohamashi Tobu Hospital, 3-6-1 Shimosueyoshi, Tsurumi-ku, Yokohama, Kanagawa 230-0012, Japan.
| | - Hirotatsu Tsuchikame
- Department of Radiology, Saiseikai Yokohamashi Tobu Hospital, 3-6-1 Shimosueyoshi, Tsurumi-ku, Yokohama, Kanagawa 230-0012, Japan.
| | - Masaaki Shishido
- Department of Radiology, Saiseikai Yokohamashi Tobu Hospital, 3-6-1 Shimosueyoshi, Tsurumi-ku, Yokohama, Kanagawa 230-0012, Japan.
| | - Kana Nishi
- Department of Radiology, Saiseikai Yokohamashi Tobu Hospital, 3-6-1 Shimosueyoshi, Tsurumi-ku, Yokohama, Kanagawa 230-0012, Japan
| | - Shinya Kojima
- Department of Radiological, Technology, Faculty of Medical Technology, Teikyo University, 2-11-1 Kaga, Itabashi-ku, Tokyo 173-8605, Japan.
| | - Tatsuya Hayashi
- Department of Radiological, Technology, Faculty of Medical Technology, Teikyo University, 2-11-1 Kaga, Itabashi-ku, Tokyo 173-8605, Japan.
| | - Kentaro Suzuki
- Department of Radiological Technology, Toranomon Hospital, 2-2-2 Tranomon, Minato-ku, Tokyo 105-8470, Japan; Department of Radiation Oncology, Graduated School of Medicine, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo, Japan.
| |
Collapse
|
4
|
Ito T. [[SPECT] 1. Experimental Evaluation and Clinical Indication of the GE NM/CT 870 CZT Clinical SPECT System]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:536-541. [PMID: 35598965 DOI: 10.6009/jjrt.2022-2024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Affiliation(s)
- Toshimune Ito
- Department of Radiological, Technology, Faculty of Medical Technology, Teikyo University
| |
Collapse
|
5
|
Yamane T, Takahashi M, Matsusaka Y, Fukushima K, Seto A, Kuji I, Matsunari I. Satisfied quantitative value can be acquired by short-time bone SPECT/CT using a whole-body cadmium-zinc-telluride gamma camera. Sci Rep 2021; 11:24320. [PMID: 34934145 PMCID: PMC8692318 DOI: 10.1038/s41598-021-03853-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 12/10/2021] [Indexed: 11/15/2022] Open
Abstract
The aim of this study was to evaluate the quantitative values of short-time scan (STS) of metastatic lesions compared with a standard scan (SS) when acquired by whole-body bone SPECT/CT with cadmium-zinc-telluride (CZT) detectors. We retrospectively reviewed 13 patients with bone metastases from prostate cancer, who underwent SPECT/CT performed on whole-body CZT gamma cameras. STSs were obtained using 75, 50, 25, 10, and 5% of the list-mode data for SS, respectively. Regions of interest (ROIs) were set on the increased uptake areas diagnosed as metastases. Intraclass correlation coefficients (ICCs) of standardized uptake values (SUVs) for the ROIs were calculated between the SS and each STS, and ICC ≥ 0.8 was set as a perfect correlation. Moreover, the repeatability coefficient (RC) was calculated, and RC ≤ 20% was defined as acceptable. A total of 152 metastatic lesions were included in the analysis. The ICCs between the SS vs. 75%-STS, 50%-STS, 25%-STS, 10%-STS, and 5%-STS were 0.999, 0.997, 0.994, 0.983, and 0.955, respectively. The RCs of the SS vs. 75%-STS, 50%-STS, 25%-STS, 10%-STS, and 5%-STS were 7.9, 12.4, 19.8, 30.8, and 41.3%, respectively. When evaluating the quality of CZT bone SPECT/CT acquired by a standard protocol, 25%-STS may provide adequate quantitative values.
Collapse
Affiliation(s)
- Tomohiko Yamane
- Division of Nuclear Medicine, Department of Radiology, Saitama Medical University Hospital, 38 Moro-Hongo, Moroyama, 350-0495, Japan.
- Department of Nuclear Medicine, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-0491, Japan.
| | - Masafumi Takahashi
- Department of Central Radiological Technology, Saitama Medical University Hospital, 38 Moro-Hongo, Moroyama, 350-0495, Japan
| | - Yohji Matsusaka
- Department of Nuclear Medicine, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-0491, Japan
| | - Kenji Fukushima
- Department of Nuclear Medicine, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-0491, Japan
| | - Akira Seto
- Department of Nuclear Medicine, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-0491, Japan
| | - Ichiei Kuji
- Department of Nuclear Medicine, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-0491, Japan
| | - Ichiro Matsunari
- Division of Nuclear Medicine, Department of Radiology, Saitama Medical University Hospital, 38 Moro-Hongo, Moroyama, 350-0495, Japan
| |
Collapse
|
6
|
van der Meulen NP, Strobel K, Lima TVM. New Radionuclides and Technological Advances in SPECT and PET Scanners. Cancers (Basel) 2021; 13:cancers13246183. [PMID: 34944803 PMCID: PMC8699425 DOI: 10.3390/cancers13246183] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 12/03/2021] [Accepted: 12/06/2021] [Indexed: 11/16/2022] Open
Abstract
Simple Summary Advances in nuclear medicine are made by technological and radionuclide improvements. Throughout nuclear medicine’s history, these advances were often intertwined and complementary based on different clinical questions, availability and need. This paper covers some of these developments in radionuclides and instrumentation. Abstract Developments throughout the history of nuclear medicine have involved improvements in both instrumentation and radionuclides, which have been intertwined. Instrumentation developments always occurred during the search to improving devices’ sensitivity and included advances in detector technology (with the introduction of cadmium zinc telluride and digital Positron Emission Tomography—PET-devices with silicon photomultipliers), design (total body PET) and configuration (ring-shaped, Single-Photon Emission Computed Tomography (SPECT), Compton camera). In the field of radionuclide development, we observed the continual changing of clinically used radionuclides, which is sometimes influenced by instrumentation technology but also driven by availability, patient safety and clinical questions. Some areas, such as tumour imaging, have faced challenges when changing radionuclides based on availability, when this produced undesirable clinical findings with the introduction of unclear focal uptakes and unspecific uptakes. On the other end of spectrum, further developments of PET technology have seen a resurgence in its use in nuclear cardiology, with rubidium-82 from strontium-82/rubidium-82 generators being the radionuclide of choice, moving away from SPECT nuclides thallium-201 and technetium-99m. These continuing improvements in both instrumentation and radionuclide development have helped the growth of nuclear medicine and its importance in the ever-evolving range of patient care options.
Collapse
Affiliation(s)
- Nicholas P. van der Meulen
- Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Paul Scherrer Institute, 5232 Villigen, Switzerland
- Laboratory of Radiochemistry, Paul Scherrer Institute, 5232 Villigen, Switzerland
- Correspondence: (N.P.v.d.M.); (T.V.M.L.)
| | - Klaus Strobel
- Department of Radiology and Nuclear Medicine, Luzerner Kantonsspital, 6000 Luzern, Switzerland;
| | - Thiago Viana Miranda Lima
- Department of Radiology and Nuclear Medicine, Luzerner Kantonsspital, 6000 Luzern, Switzerland;
- Institute of Radiation Physics, Lausanne University Hospital, University of Lausanne, 1007 Lausanne, Switzerland
- Correspondence: (N.P.v.d.M.); (T.V.M.L.)
| |
Collapse
|
7
|
Nappi C, Gaudieri V, Petretta M. Simultaneous dual-tracer 99mTc-tetrofosmin and 123I-BMIPP acquisition with CZT for ischemic memory: The future approaches to image the past. J Nucl Cardiol 2021; 28:196-198. [PMID: 30701444 DOI: 10.1007/s12350-019-01614-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Accepted: 01/16/2019] [Indexed: 12/01/2022]
Affiliation(s)
- Carmela Nappi
- Department of Advanced Biomedical Sciences, University Federico II, Naples, Italy
| | - Valeria Gaudieri
- Department of Advanced Biomedical Sciences, University Federico II, Naples, Italy
| | - Mario Petretta
- Department of Translational Medical Sciences, University Federico II, Naples, Italy.
| |
Collapse
|
8
|
Ito T, Matsusaka Y, Onoguchi M, Ichikawa H, Okuda K, Shibutani T, Shishido M, Sato K. Experimental evaluation of the GE NM/CT 870 CZT clinical SPECT system equipped with WEHR and MEHRS collimator. J Appl Clin Med Phys 2021; 22:165-177. [PMID: 33426812 PMCID: PMC7882118 DOI: 10.1002/acm2.13158] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 11/27/2020] [Accepted: 12/15/2020] [Indexed: 11/17/2022] Open
Abstract
Purpose A high‐energy‐resolution whole‐body SPECT‐CT device (NM/CT 870 CZT; C‐SPECT) equipped with a CZT detector has been developed and is being used clinically. A MEHRS collimator has also been developed recently, with an expected improvement in imaging accuracy using medium‐energy radionuclides. The objective of this study was to compare and analyze the accuracies of the following devices: a WEHR collimator and the MEHRS collimator installed on a C‐SPECT, and a NaI scintillation detector‐equipped Anger‐type SPECT (A‐SPECT) scanner, with a LEHR and LMEGP. Methods A line phantom was used to measure the energy resolutions including collimator characteristics in the planar acquisition of each device using 99mTc and 123I. We also measured the system's sensitivity and high‐contrast resolution using a lead bar phantom. We evaluated SPECT spatial resolution, high‐contrast resolution, radioactivity concentration linearity, and homogeneity, using a basic performance evaluation phantom. In addition, the effect of scatter correction was evaluated by varying the sub window (SW) employed for scattering correction. Results The energy resolution with 99mTc was 5.6% in C‐SPECT with WEHR and 9.9% in A‐SPECT with LEHR. Using 123I, the results were 9.1% in C‐SPECT with WEHR, 5.5% in C‐SPECT with MEHRS, and 10.4% in A‐SPECT with LMEGP. The planar spatial resolution was similar under all conditions, but C‐SPECT performed better in SPECT acquisition. High‐contrast resolution was improved in C‐SPECT under planar condition and SPECT. The sensitivity and homogeneity were improved by setting the SW for scattering correction to 3% of the main peak in C‐SPECT. Conclusion C‐SPECT demonstrates excellent energy resolution and improved high‐contrast resolution for each radionuclide. In addition, when using 123I, careful attention should be paid to SW for scatter correction. By setting the appropriate SW, C‐SPECT with MEHRS has an excellent scattered ray removal effect, and highly homogenous imaging is possible while maintaining the high‐contrast resolution.
Collapse
Affiliation(s)
- Toshimune Ito
- Department of Radiology, Saiseikai Yokohamashi Tobu Hospital, Yokohama, Japan
| | - Yohji Matsusaka
- Department of Diagnostic Radiology, School of Medicine, Keio University, Tokyo, Japan
| | - Masahisa Onoguchi
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
| | - Hajime Ichikawa
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan.,Department of Radiology, Toyohashi Municipal Hospital, Toyohashi, Japan
| | - Koichi Okuda
- Department of Physics, Kanazawa Medical University, Kahoku, Ishikawa, Japan
| | - Takayuki Shibutani
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
| | - Masaaki Shishido
- Department of Radiology, Saiseikai Yokohamashi Tobu Hospital, Yokohama, Japan.,Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
| | - Kozo Sato
- Department of Diagnostic Radiology, Saiseikai Yokohamashi Tobu Hospital, Yokohama, Kanagawa, Japan
| |
Collapse
|
9
|
Ge Y, Leong-Poi H. Ischemic Memory Imaging: The Quest for the Holy Grail Continues. J Am Soc Echocardiogr 2019; 32:1487-1490. [PMID: 31679582 DOI: 10.1016/j.echo.2019.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Revised: 09/10/2019] [Accepted: 09/10/2019] [Indexed: 11/30/2022]
Affiliation(s)
- Yin Ge
- Division of Cardiology, St. Michael's Hospital, Unity Health Toronto, University of Toronto, Toronto, Ontario, Canada
| | - Howard Leong-Poi
- Division of Cardiology, St. Michael's Hospital, Unity Health Toronto, University of Toronto, Toronto, Ontario, Canada.
| |
Collapse
|
10
|
Slomka PJ, Miller RJ, Hu LH, Germano G, Berman DS. Solid-State Detector SPECT Myocardial Perfusion Imaging. J Nucl Med 2019; 60:1194-1204. [DOI: 10.2967/jnumed.118.220657] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Accepted: 06/18/2019] [Indexed: 02/07/2023] Open
|