1
|
Tenchurin TK, Rodina AV, Saprykin VP, Gorshkova LV, Mikhutkin AA, Kamyshinsky RA, Yakovlev DS, Vasiliev AL, Chvalun SN, Grigoriev TE. The Performance of Nonwoven PLLA Scaffolds of Different Thickness for Stem Cells Seeding and Implantation. Polymers (Basel) 2022; 14:polym14204352. [PMID: 36297930 PMCID: PMC9610477 DOI: 10.3390/polym14204352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2022] [Revised: 09/24/2022] [Accepted: 10/13/2022] [Indexed: 11/22/2022] Open
Abstract
The 3D reconstruction of 100 μm- and 600 μm-thick fibrous poly-L/L-lactide scaffolds was performed by confocal laser scanning microscopy and supported by scanning electron microscopy and showed that the density of the fibers on the side adjacent to the electrode is higher, which can affect cell diffusion, while the pore size is generally the same. Bone marrow mesenchymal stem cells cultured in a 600 μm-thick scaffold formed colonies and produced conditions for cell differentiation. An in vitro study of stem cells after 7 days revealed that cell proliferation and hepatocyte growth factor release in the 600 μm-thick scaffold were higher than in the 100 μm-thick scaffold. An in vivo study of scaffolds with and without stem cells implanted subcutaneously onto the backs of recipient mice was carried out to test their biodegradation and biocompatibility over a 0-3-week period. The cells seeded onto the 600 μm-thick scaffold promoted significant neovascularization in vivo. After 3 weeks, a significant number of donor cells persisted only on the inside of the 600 μm-thick scaffold. Thus, the use of bulkier matrices allows to prolong the effect of secretion of growth factors by stem cells during implantation. These 600 μm-thick scaffolds could potentially be utilized to repair and regenerate injuries with stem cell co-culture for vascularization of implant.
Collapse
Affiliation(s)
| | - Alla V. Rodina
- National Research Centre “Kurchatov Institute”, 123098 Moscow, Russia
| | - Vladimir P. Saprykin
- Natural Sciences Department, Moscow Region State University, 105005 Moscow, Russia
| | - Lada V. Gorshkova
- National Research Centre “Kurchatov Institute”, 123098 Moscow, Russia
| | | | - Roman A. Kamyshinsky
- National Research Centre “Kurchatov Institute”, 123098 Moscow, Russia
- Shubnikov Institute of Crystallography of FSRC “Crystallography and Photonics” RAS, 119333 Moscow, Russia
| | - Dmitry S. Yakovlev
- Russian Quantum Center, Skolkovo, 121205 Moscow, Russia
- Institute of Nano-, Bio-, Information, Cognitive and Socio-Humanistic Sciences and Technologies, Moscow Institute of Physics and Technology, State University, 141707 Dolgoprudny, Russia
| | - Alexander L. Vasiliev
- National Research Centre “Kurchatov Institute”, 123098 Moscow, Russia
- Shubnikov Institute of Crystallography of FSRC “Crystallography and Photonics” RAS, 119333 Moscow, Russia
- Institute of Nano-, Bio-, Information, Cognitive and Socio-Humanistic Sciences and Technologies, Moscow Institute of Physics and Technology, State University, 141707 Dolgoprudny, Russia
- Correspondence: ; Tel.: +7-910-4130115
| | - Sergey N. Chvalun
- National Research Centre “Kurchatov Institute”, 123098 Moscow, Russia
| | - Timofey E. Grigoriev
- National Research Centre “Kurchatov Institute”, 123098 Moscow, Russia
- Institute of Nano-, Bio-, Information, Cognitive and Socio-Humanistic Sciences and Technologies, Moscow Institute of Physics and Technology, State University, 141707 Dolgoprudny, Russia
| |
Collapse
|
2
|
Kamyshinsky RA, Patsaev TD, Tenchurin TK, Zagoskin YD, Grigoriev TE, Darienko KA, Panteleyev AA, Chvalun SN, Vasiliev AL. Environmental Scanning Electron Microscopy of Dermal Fibroblasts on Various Types of Polymer Scaffolds. CRYSTALLOGR REP+ 2020. [DOI: 10.1134/s1063774520050107] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
3
|
Kamyshinskii RA, Orekhov AS, Grigor’ev TE, Kuevda EV, Gubareva EA, Tokaev KV, Chvalun SN, Vasil’ev AL. Comparative Analysis of Different Methods of Scanning Electron Microscopy and Test Preparation in Biological Tissue Studies. CRYSTALLOGR REP+ 2019. [DOI: 10.1134/s106377451903012x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|