Jamshidi N, Chiang J. Inline balloon-assisted vascular sheath fragment removal.
CVIR Endovasc 2020;
3:53. [PMID:
32886241 PMCID:
PMC7474008 DOI:
10.1186/s42155-020-00142-1]
[Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Accepted: 07/29/2020] [Indexed: 01/27/2023] Open
Abstract
Background
Unretrievable foreign bodies are associated with high morbidity and mortality. While the majority of reported cases involve the venous circulation, intra-arterial foreign body displacement have the potential to migrate more distally with a higher risk for dissection and hemorrhagic complications during retrieval. As the number of intravascular procedures continues to increase, there is also likely to be a concomittant increase in the number of retrieval procedures, particular for fractured catheters and sheaths. Although snaring is frequently the traditional, ‘go-to’ method for retrieval, there are inherent risks of further dislodgement or fracture.
Case report
We describe a case that involves retrieval of a fractured sheath that originated in the common femoral artery but migrated into the popliteal artery. Different retrieval approaches were employed, however ultimately balloon assisted, over-the-wire retrieval was the successful approach.
Conclusions
We anticipate that over-the-wire, inline-retrieval approaches will continue to grow in popularity and use, particularly with respect to manipulation within the arterial circulation.
Collapse