Kongkaew S, Janduang S, Srilikhit A, Kaewnu K, Thipwimonmas Y, Cotchim S, Torrarit K, Phua CH, Limbut W. Waste DVD polycarbonate substrate for screen-printed carbon electrode modified with PVP-stabilized AuNPs for continuous free chlorine detection. Talanta 2024; 277:126406. [PMID: 38901193 DOI: 10.1016/j.talanta.2024.126406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 06/07/2024] [Accepted: 06/09/2024] [Indexed: 06/22/2024]
Abstract
An electrochemical free chlorine sensor was developed by modifying a lab-made screen-printed carbon electrode (SPCE) with gold nanoparticles synthesized with polyvinylpyrrolidone (AuNPs-PVP). The electrode was made by screen printing carbon ink on a waste digital versatile disc (SPC-wDVD). PVP was used to stabilize AuNPs. Scanning electron microscopy showed that AuNPs aggregated without the stabilizer. The electrochemical behavior of the SPC-wDVD was evaluated by comparison with commercial SPCEs from two companies. Electrochemical characterization involved cyclic voltammetry and electrochemical impedance spectroscopy. The detection of free chlorine in water samples was continuous, facilitated by a flow-injection system. In the best condition, the developed sensor exhibited linearity from 0.25 to 3.0 and 3.0 to 500 mg L-1. The limit of detection was 0.1 mg L-1. The stability of the sensor enabled the detection of free chlorine at least 475 times with an RSD of 3.2 %. The AuNPs-PVP/SPC-wDVD was able to detect free chlorine in drinking water, tap water and swimming pool water. The agreement between the results obtained with the proposed method and the standard spectrophotometric method confirmed the precision of the developed sensor.
Collapse
Affiliation(s)
- Supatinee Kongkaew
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Santipap Janduang
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Angkana Srilikhit
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Krittapas Kaewnu
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Yudtapum Thipwimonmas
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Suparat Cotchim
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Kamonchanok Torrarit
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Cheng Ho Phua
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Warakorn Limbut
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
| |
Collapse
|
2
|
Rahmawati I, Saepudin E, Fiorani A, Einaga Y, Ivandini TA. Electrogenerated chemiluminescence of luminol at a boron-doped diamond electrode for the detection of hypochlorite. Analyst 2022; 147:2696-2702. [PMID: 35608289 DOI: 10.1039/d2an00540a] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Electrogenerated chemiluminescence (ECL) of luminol at a boron-doped diamond electrode has been used for hypochlorite determination. The presence of H2O2 induces the generation of the ECL signals of luminol. In contrast, the presence of hypochlorite oxidizes luminol directly to decrease the ECL signals of luminol. Accordingly, a decrease of the ECL signals of luminol in the presence of H2O2 was used as the signal response for hypochlorite detection. A linear decrease of ECL signals with the NaClO concentration in the range from 0 to 20 μM was observed with a sensitivity of 18.56 a.u. μM-1 cm-2. An estimated detection limit of 0.88 μM was achieved, which is around one order lower than the detection limit obtained using the normal electrochemical method with the same electrode. The system also provides a good selectivity towards Cu2+ and Na+. A reproducibility of 3.40%RSD was noted for 15 repetitive measurements. The analytical performance was found to be favourable in comparison to those of other typical electrochemical and electrochemiluminescence methods, indicating that it is applicable for real sample detection.
Collapse
Affiliation(s)
- Isnaini Rahmawati
- Department of Chemistry, Faculty of Mathematics and Sciences, Universitas Indonesia, Kampus UI Depok, Jakarta 16424, Indonesia.
| | - Endang Saepudin
- Department of Chemistry, Faculty of Mathematics and Sciences, Universitas Indonesia, Kampus UI Depok, Jakarta 16424, Indonesia.
| | - Andrea Fiorani
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, 223-8522, Yokohama, Japan
| | - Yasuaki Einaga
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, 223-8522, Yokohama, Japan
| | - Tribidasari A Ivandini
- Department of Chemistry, Faculty of Mathematics and Sciences, Universitas Indonesia, Kampus UI Depok, Jakarta 16424, Indonesia.
| |
Collapse
|
6
|
Zubiarrain-Laserna A, Angizi S, Akbar MA, Divigalpitiya R, Selvaganapathy PR, Kruse P. Detection of free chlorine in water using graphene-like carbon based chemiresistive sensors. RSC Adv 2022; 12:2485-2496. [PMID: 35425275 PMCID: PMC8979178 DOI: 10.1039/d1ra08264g] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 01/12/2022] [Indexed: 01/02/2023] Open
Abstract
Free chlorine is the most commonly used water disinfectant. Measuring its concentration during and after water treatment is crucial to ensure its effectiveness. However, many of the existing methods do not allow for continuous on-line monitoring. Here we demonstrate a solid state chemiresistive sensor using graphene-like carbon (GLC) that overcomes that issue. GLC films that were either bare or non-covalently functionalized with the redox-active phenyl-capped aniline tetramer (PCAT) were successfully employed to quantify aqueous free chlorine, although functionalized devices showed better performance. The response of the sensors to increasing concentrations of free chlorine followed a Langmuir adsorption isotherm in the two tested ranges: 0.01–0.2 ppm and 0.2–1.4 ppm. The limit of detection was estimated to be 1 ppb, permitting the detection of breaches in chlorine filters. The devices respond to decreasing levels of free chlorine without the need for a reset, allowing for the continuous monitoring of fluctuations in the concentration. The maximum sensor response and saturation concentration were found to depend on the thickness of the GLC film. Hence, the sensitivity and dynamic range of the sensors can be tailored to different applications by adjusting the thickness of the films. Tap water samples from a residential area were tested using these sensors, which showed good agreement with standard colorimetric measurement methods. The devices did not suffer from interferences in the presence of ions commonly found in drinking water. Overall, these sensors are a cost-effective option for the continuous automated monitoring of free chlorine in drinking water. Chemiresistive sensors based on graphene-like carbon films are very stable and sensitive. They can be used for continuous online monitoring of free chlorine.![]()
Collapse
Affiliation(s)
- Ana Zubiarrain-Laserna
- Department of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada
| | - Shayan Angizi
- Department of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada
| | - Md Ali Akbar
- Department of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada
| | | | | | - Peter Kruse
- Department of Chemistry and Chemical Biology, McMaster University 1280 Main Street West Hamilton Ontario L8S 4M1 Canada
| |
Collapse
|
7
|
Siddiqui J, Jamal Deen M. Biodegradable asparagine–graphene oxide free chlorine sensors fabricated using solution-based processing. Analyst 2022; 147:3643-3651. [DOI: 10.1039/d2an00533f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A free chlorine-sensing biodegradable ink was made by functionalizing asparagine onto graphene oxide then deposited on an electrode. The sensor showed a sensitivity of 0.30 μA ppm−1, selectivity amid interfering ions, and low temperature dependence.
Collapse
Affiliation(s)
- Junaid Siddiqui
- Electrical and Computer Engineering (ECE) Department, McMaster University, 1280 Main Street W, Hamilton, Ontario L8S 4K1, Canada
| | - M. Jamal Deen
- Electrical and Computer Engineering (ECE) Department, McMaster University, 1280 Main Street W, Hamilton, Ontario L8S 4K1, Canada
| |
Collapse
|
8
|
Zhang Y, Li Z, Guo X, Liu G, Zhang S. Potentiometric Sensor Based on Carbon Paste Electrode for Monitoring Total Residual Chlorine in Electrolytically-Treated Ballast Water. SENSORS (BASEL, SWITZERLAND) 2021; 21:E350. [PMID: 33430170 PMCID: PMC7825626 DOI: 10.3390/s21020350] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 12/30/2020] [Accepted: 01/02/2021] [Indexed: 11/18/2022]
Abstract
A new potentiometric sensor based on modified carbon paste electrode (CPE) was prepared for the sensitive and selective detection of total residual chlorine (TRC) in simulated electrolytically-treated ballast water (BW). The modified CPE was prepared using ferrocene (Fc) as the sensing species and paraffin oil as the binder. It is revealed that the addition of Fc can significantly shorten the response time and improve the reproducibility, selectivity, and stability of the sensor. The open circuit potential of the Fc-CPE is in linear proportion to the logarithm of TRC within the TRC concentration range from 1 mg∙dm-3 to 15 mg∙dm-3. In addition, the Fc-CPE sensor exhibits good selectivity to TRC over a wide concentration range of the possible co-exiting interference ions in seawater. The Fc-CPE electrode can be used as a convenient and reliable sensor for the continuous monitoring of TRC during the electrolytic treatment of BW.
Collapse
Affiliation(s)
- Yaning Zhang
- School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100, China;
| | - Zhihui Li
- Institute of Marine Science and Technology, Shandong University, Qingdao 266237, China; (Z.L.); (X.G.); (G.L.)
| | - Xiaotong Guo
- Institute of Marine Science and Technology, Shandong University, Qingdao 266237, China; (Z.L.); (X.G.); (G.L.)
| | - Guangzhou Liu
- Institute of Marine Science and Technology, Shandong University, Qingdao 266237, China; (Z.L.); (X.G.); (G.L.)
| | - Shuyong Zhang
- Institute of Marine Science and Technology, Shandong University, Qingdao 266237, China; (Z.L.); (X.G.); (G.L.)
| |
Collapse
|
10
|
Boda SK, Li X, Xie J. Electrospraying an enabling technology for pharmaceutical and biomedical applications: A review. JOURNAL OF AEROSOL SCIENCE 2018; 125:164-181. [PMID: 30662086 PMCID: PMC6333098 DOI: 10.1016/j.jaerosci.2018.04.002] [Citation(s) in RCA: 82] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Electrospraying (ES) is a robust and versatile technique for the fabrication of micro- and nanoparticulate materials of various compositions, morphologies, shapes, textures and sizes. The physics of ES provides a great degree of flexibility towards the materials design of choice with desired physicochemical and biological properties. Not surprising, this technology has become an important tool for the production of micro- and nanostructured materials, especially in the pharmaceutical and biomedical arena. In this review, a basic introduction to the fundamentals of ES along with a brief description of the experimental parameters that can be manipulated to obtain micro- and nanostructured materials of desired composition, size, and configuration are outlined. A greater focus of this review is to bring to light the broad range of electrosprayed materials and their applications in drug delivery, biomedical imaging, implant coating, tissue engineering, and sensing. Taken together, this review will provide an appreciation of this unique technology, which can be used to fabricate micro- and nanostructured materials with tremendous applications in the pharmaceutical and biomedical fields.
Collapse
Affiliation(s)
- Sunil Kumar Boda
- Department of Surgery-Transplant and Mary & Dick Holland Regenerative Medicine Program, College of Medicine, University of Nebraska Medical Center, Omaha, Nebraska 68198, United States
| | - Xiaoran Li
- Innovation Center for Textile Science and Technology, Donghua University, Shanghai 200051, China
| | - Jingwei Xie
- Department of Surgery-Transplant and Mary & Dick Holland Regenerative Medicine Program, College of Medicine, University of Nebraska Medical Center, Omaha, Nebraska 68198, United States
| |
Collapse
|
12
|
Bhati VS, Ranwa S, Rajamani S, Kumari K, Raliya R, Biswas P, Kumar M. Improved Sensitivity with Low Limit of Detection of a Hydrogen Gas Sensor Based on rGO-Loaded Ni-Doped ZnO Nanostructures. ACS APPLIED MATERIALS & INTERFACES 2018. [PMID: 29537250 DOI: 10.1021/acsami.7b17877] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
We report enhanced hydrogen-gas-sensing performance of a Ni-doped ZnO sensor decorated with the optimum concentration of reduced graphene oxide (rGO). Ni-doped ZnO nanoplates were grown by radio frequency sputtering, rGO was synthesized by Hummer's method and decorated by the drop cast method of various concentration of rGO (0-1.5 wt %). The current-voltage characteristics of the rGO-loaded sensor are highly influenced by the loading concentration of rGO, where current conduction decreases and sensor resistance increases as the rGO concentration is increased up to 0.75 wt % because of the formation of various Schottky heterojunctions at rGO/ZnO interfaces. With the combined effect of more active site availability and formation of various p-n heterojunctions due to the optimum loading concentration of rGO (0.75 wt %), the sensor shows the maximum sensing response of ∼63.8% for 100 ppm hydrogen at moderate operating temperature (150 °C). The rGO-loaded sensors were able to detect a minimum of 1 ppm hydrogen concentration and showed high selectivity. However, a further increase in the rGO concentration (1.5 wt %) leads to the reduction of the relative response of hydrogen gas, ascribed to the formation of interconnections of rGO between electrodes. Therefore, it reduces the total resistance of the sensor and minimizes the effect of p-n heterojunction on sensor response.
Collapse
Affiliation(s)
| | - Sapana Ranwa
- Thin Film Laboratory, Department of Physics , Indian Institute of Technology Delhi , Hauz Khas, New Delhi 110016 , India
| | | | - Kusum Kumari
- Department of Physics , National Institute of Technology , Warangal 506004 , Telangana , India
| | - Ramesh Raliya
- Aerosol and Air Quality Research Laboratory, Department of Energy, Environmental and Chemical Engineering , Washington University at St. Louis , St. Louis , Missouri 63130 , United States
| | - Pratim Biswas
- Aerosol and Air Quality Research Laboratory, Department of Energy, Environmental and Chemical Engineering , Washington University at St. Louis , St. Louis , Missouri 63130 , United States
| | | |
Collapse
|