1
|
Arminio M, Carbonaro D, Morbiducci U, Gallo D, Chiastra C. Fluid-structure interaction simulation of mechanical aortic valves: a narrative review exploring its role in total product life cycle. FRONTIERS IN MEDICAL TECHNOLOGY 2024; 6:1399729. [PMID: 39011523 PMCID: PMC11247014 DOI: 10.3389/fmedt.2024.1399729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Accepted: 06/07/2024] [Indexed: 07/17/2024] Open
Abstract
Over the last years computer modelling and simulation has emerged as an effective tool to support the total product life cycle of cardiovascular devices, particularly in the device preclinical evaluation and post-market assessment. Computational modelling is particularly relevant for heart valve prostheses, which require an extensive assessment of their hydrodynamic performance and of risks of hemolysis and thromboembolic complications associated with mechanically-induced blood damage. These biomechanical aspects are typically evaluated through a fluid-structure interaction (FSI) approach, which enables valve fluid dynamics evaluation accounting for leaflets movement. In this context, the present narrative review focuses on the computational modelling of bileaflet mechanical aortic valves through FSI approach, aiming to foster and guide the use of simulations in device total product life cycle. The state of the art of FSI simulation of heart valve prostheses is reviewed to highlight the variety of modelling strategies adopted in the literature. Furthermore, the integration of FSI simulations in the total product life cycle of bileaflet aortic valves is discussed, with particular emphasis on the role of simulations in complementing and potentially replacing the experimental tests suggested by international standards. Simulations credibility assessment is also discussed in the light of recently published guidelines, thus paving the way for a broader inclusion of in silico evidence in regulatory submissions. The present narrative review highlights that FSI simulations can be successfully framed within the total product life cycle of bileaflet mechanical aortic valves, emphasizing that credible in silico models evaluating the performance of implantable devices can (at least) partially replace preclinical in vitro experimentation and support post-market biomechanical evaluation, leading to a reduction in both time and cost required for device development.
Collapse
Affiliation(s)
| | | | | | | | - Claudio Chiastra
- PoliToMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| |
Collapse
|
2
|
Bornoff J, Gill HS, Najar A, Perkins IL, Cookson AN, Fraser KH. Overset meshing in combination with novel blended weak-strong fluid-structure interactions for simulations of a translating valve in series with a second valve. Comput Methods Biomech Biomed Engin 2024; 27:736-750. [PMID: 37071538 DOI: 10.1080/10255842.2023.2199903] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 03/30/2023] [Indexed: 04/19/2023]
Abstract
Mechanical circulatory support (MCS) devices can bridge the gap to transplant whilst awaiting a viable donor heart. The Realheart Total Artificial Heart is a novel positive-displacement MCS that generates pulsatile flow via bileaflet mechanical valves. This study developed a combined computational fluid dynamics and fluid-structure interaction (FSI) methodology for simulating positive displacement bileaflet valves. Overset meshing discretised the fluid domain, and a blended weak-strong coupling FSI algorithm was combined with variable time-stepping. Four operating conditions of relevant stroke lengths and rates were assessed. The results demonstrated this modelling strategy is stable and efficient for modelling positive-displacement artificial hearts.
Collapse
Affiliation(s)
- J Bornoff
- Department of Mechanical Engineering, University of Bath, Bath, UK
| | - H S Gill
- Department of Mechanical Engineering, University of Bath, Bath, UK
- Centre for Therapeutic Innovation, University of Bath, Bath, UK
| | - A Najar
- Scandinavian Real Heart AB, Västerås, Västmanland, Sweden
| | - I L Perkins
- Scandinavian Real Heart AB, Västerås, Västmanland, Sweden
| | - A N Cookson
- Department of Mechanical Engineering, University of Bath, Bath, UK
- Centre for Therapeutic Innovation, University of Bath, Bath, UK
| | - K H Fraser
- Department of Mechanical Engineering, University of Bath, Bath, UK
- Centre for Therapeutic Innovation, University of Bath, Bath, UK
| |
Collapse
|
3
|
Bornoff J, Najar A, Fresiello L, Finocchiaro T, Perkins IL, Gill H, Cookson AN, Fraser KH. Fluid-structure interaction modelling of a positive-displacement Total Artificial Heart. Sci Rep 2023; 13:5734. [PMID: 37059748 PMCID: PMC10104863 DOI: 10.1038/s41598-023-32141-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 03/23/2023] [Indexed: 04/16/2023] Open
Abstract
For those suffering from end-stage biventricular heart failure, and where a heart transplantation is not a viable option, a Total Artificial Heart (TAH) can be used as a bridge to transplant device. The Realheart TAH is a four-chamber artificial heart that uses a positive-displacement pumping technique mimicking the native heart to produce pulsatile flow governed by a pair of bileaflet mechanical heart valves. The aim of this work was to create a method for simulating haemodynamics in positive-displacement blood pumps, using computational fluid dynamics with fluid-structure interaction to eliminate the need for pre-existing in vitro valve motion data, and then use it to investigate the performance of the Realheart TAH across a range of operating conditions. The device was simulated in Ansys Fluent for five cycles at pumping rates of 60, 80, 100 and 120 bpm and at stroke lengths of 19, 21, 23 and 25 mm. The moving components of the device were discretised using an overset meshing approach, a novel blended weak-strong coupling algorithm was used between fluid and structural solvers, and a custom variable time stepping scheme was used to maximise computational efficiency and accuracy. A two-element Windkessel model approximated a physiological pressure response at the outlet. The transient outflow volume flow rate and pressure results were compared against in vitro experiments using a hybrid cardiovascular simulator and showed good agreement, with maximum root mean square errors of 15% and 5% for the flow rates and pressures respectively. Ventricular washout was simulated and showed an increase as cardiac output increased, with a maximum value of 89% after four cycles at 120 bpm 25 mm. Shear stress distribution over time was also measured, showing that no more than [Formula: see text]% of the total volume exceeded 150 Pa at a cardiac output of 7 L/min. This study showed this model to be both accurate and robust across a wide range of operating points, and will enable fast and effective future studies to be undertaken on current and future generations of the Realheart TAH.
Collapse
Affiliation(s)
- Joseph Bornoff
- Department of Mechanical Engineering, University of Bath, Bath, UK
| | - Azad Najar
- Scandinavian Real Heart AB, Västerås, Sweden
| | - Libera Fresiello
- Faculty of Science and Technology, University of Twente, Twente, The Netherlands
| | | | | | - Harinderjit Gill
- Department of Mechanical Engineering, University of Bath, Bath, UK
- Centre for Therapeutic Innovation, University of Bath, Bath, UK
| | - Andrew N Cookson
- Department of Mechanical Engineering, University of Bath, Bath, UK
- Centre for Therapeutic Innovation, University of Bath, Bath, UK
| | - Katharine H Fraser
- Department of Mechanical Engineering, University of Bath, Bath, UK.
- Centre for Therapeutic Innovation, University of Bath, Bath, UK.
| |
Collapse
|
4
|
Chen A, Azriff Basri A, Ismail NB, Arifin Ahmad K. Hemodynamic Effects of Subaortic Stenosis on Blood Flow Characteristics of a Mechanical Heart Valve Based on OpenFOAM Simulation. Bioengineering (Basel) 2023; 10:312. [PMID: 36978704 PMCID: PMC10045469 DOI: 10.3390/bioengineering10030312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 02/22/2023] [Accepted: 02/28/2023] [Indexed: 03/06/2023] Open
Abstract
Subaortic stenosis (SAS) is a common congenital heart disease that can cause significant morbidity and mortality if not treated promptly. Patients with heart valve disease are prone to complications after replacement surgery, and the existence of SAS can accelerates disease progression, so timely diagnosis and treatment are required. However, the effects of subaortic stenosis on mechanical heart valves (MHV) are unknown. This study aimed to investigate flow characteristics in the presence of subaortic stenosis and computationally quantify the effects on the hemodynamics of MHV. Through the numerical simulation method, the flow characteristics and related parameters in the presence of SAS can be more intuitively observed. Based on its structure, there are three types of SAS: Tunnel-type SAS (TSS); Fibromuscular annulus SAS (FSS); Discrete SAS (DSS). The first numerical simulation study on different types of SAS found that there are obvious differences among them. Among them, the tunnel-type SAS formed a separated vortex structure on the tunnel-type narrow surface, which exhibits higher wall shear force at a low obstacle percentage. However, discrete SAS showed obvious differences when there was a high percentage of obstacles, forming high peak flow, high wall shear stress, and a high-intensity complex vortex. The presence of all three types of SAS results in the formation of high-velocity jets and complex vortices in front of the MHV, leading to increased shear stress and stagnation time. These hemodynamic changes significantly increase the risk of MHV dysfunction and the development of complications. Despite differences between the three types of SAS, the resultant effects on MHV hemodynamics are consistent. Therefore, early surgical intervention is warranted in SAS patients with implanted MHV.
Collapse
Affiliation(s)
- Aolin Chen
- Department of Mechanical Engineering, Faculty of Engineering, University Putra Malaysia, Serdang 43400, Selangor, Malaysia
| | - Adi Azriff Basri
- Department of Aerospace Engineering, Faculty of Engineering, University Putra Malaysia, Serdang 43400, Selangor, Malaysia
| | - Norzian Bin Ismail
- Department of Medicine, Faculty of Medicine and Health Sciences, University Putra Malaysia, Serdang 43400, Selangor, Malaysia
| | - Kamarul Arifin Ahmad
- Department of Aerospace Engineering, Faculty of Engineering, University Putra Malaysia, Serdang 43400, Selangor, Malaysia
| |
Collapse
|
5
|
Transient Study of Flow and Cavitation Inside a Bileaflet Mechanical Heart Valve. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10072548] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
A mechanical heart valve (MHV) is an effective device to cure heart disease, which has the advantage of long life and high reliability. Due to the hemodynamic characteristics of blood, mechanical heart valves can lead to potential complications such as hemolysis, which have damage to the blood elements and thrombosis. In this paper, flowing features of the blood in the valve are analyzed and the cavitation mechanism in bileaflet mechanical heart valve (BMHV) is studied. Results show that the water hammer effect and the high-speed leakage flow effect are the primary causes of the cavitation in the valve. Compared with the high-speed leakage flow effect, the water hammer has a greater effect on the cavitation strength. The valve goes through four kinds of working condition within one heart beating period, including, fully opening stage, closing stage and fully closing stage. These four stages, respectively, make up 8.5%, 16.1%, 4.7% and 70.7% of the total period. The cavitation occurs on the fully closing stage. When the valve is in closing stage, the high pressure downstream of the valve lasts for about 20 ms and the high-speed leakage flow lasts for about 200 ms. This study systematically analyzes the causes of cavitation emerged in the process of periodic motion, which proposes the method for characterizing the intensity of the cavitation, and can be referred to for the cavitation suppression of the BHMV and similar valves.
Collapse
|
6
|
Sadipour M, Hanafizadeh P, Sadeghy K, Sattari A. Effect of Aortic Wall Deformation with Healthy and Calcified Annulus on Hemodynamic Performance of Implanted On-X Valve. Cardiovasc Eng Technol 2020; 11:141-161. [PMID: 31912432 DOI: 10.1007/s13239-019-00453-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Accepted: 12/24/2019] [Indexed: 11/27/2022]
Abstract
INTRODUCTION In this research, the hemodynamic performance of a 23-mm On-X bileaflet mechanical heart valve (BMHV) was investigated with the realistic geometry model of the valve and the deformable aorta in accelerating systole. In addition, the effect of ascending aorta flexibility and aortic annulus calcification on the complex blood flow characteristics were investigated. METHODS The geometry of the aorta is derived from the medical images, and the Ogden model has been utilized for the mechanical behavior of the ascending aorta. The 3D numerical simulation by a two-way Fluid-Structure Interaction (FSI) analysis using the Arbitrary Lagrangian-Eulerian (ALE) method was performed throughout the accelerating systolic phase. RESULTS The dynamics of the leaflets are investigated, and blood flow characteristics such as velocities, vorticities as well as viscous and turbulent shear stress were precisely captured in the flow domain specifically in the hinge region. Streamline results are in accordance with the previously reported data, which show that the flared On-X valves inlet yields a more uniform flow in accelerating systole. Simulations show that aorta flexibility or valve annulus calcification causes variations up to 7% in maximum fluid velocity and 20% in Turbulence Kinetic Energy (TKE). CONCLUSIONS In this study, the complex flow field characteristics in the new generation of BMHVs considering aorta flexibility with healthy and calcified annulus were investigated. It was found that the blood flow around the hinges region is in the danger of hemolysis and platelet activation and subsequently thromboembolism. Furthermore, the results show that similar to vessel wall deformation, considering the probable annulus calcification after valve replacement is also essential.
Collapse
Affiliation(s)
- Masod Sadipour
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Pedram Hanafizadeh
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran.
| | - Keyvan Sadeghy
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Amirmohammad Sattari
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| |
Collapse
|
7
|
Review of numerical methods for simulation of mechanical heart valves and the potential for blood clotting. Med Biol Eng Comput 2017; 55:1519-1548. [DOI: 10.1007/s11517-017-1688-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Accepted: 07/10/2017] [Indexed: 11/26/2022]
|