Wu X, Jansen KMB, Westenberg JJM, Lamb HJ, Kenjereš S. Aortic strain, flow pattern and wall shear stress in a patient-specific compliant aorta replica using Shake-the-Box. Med Eng Phys 2025; 135:104263. [PMID: 39922656 DOI: 10.1016/j.medengphy.2024.104263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 10/30/2024] [Accepted: 11/25/2024] [Indexed: 02/10/2025]
Abstract
High-fidelity in vitro flow simulator in combination with high-dimensional flow visualization techniques can offer precise and comprehensive evaluation of aortic hemodynamics. However, it is particularly challenging to create a fully transparent aorta replica that faithfully mimics the aortic curvature and stiffness. In this study, we successfully manufactured a patient-specific compliant aorta phantom with a dilated ascending aorta that can be used in vitro hemodynamic study. We conducted pulsatile flow measurement on the deformable aorta replica using advanced 4D particle tracking velocimetry - Shake-the-Box. The aortic distensibility, circumferential strain, flow pattern, wall shear stress (WSS), and turbulent kinetic energy were assessed. Furthermore, the peak velocity field and WSS distribution were compared to in vivo MRI measurements. We found that the distensibility and circumferential strain of our aortic replica fell within the physiological range of young patients. The aortic diameter changed as much as 5.4 mm (42 %) in a cardiac cycle and the aortic distensibility was 9.9 × 10-3 mmHg-1. In addition, the obtained flow pattern and WSS distribution were found in a good agreement with in vivo MRI measurement. In conclusion, the compliant aorta phantom replicated the aortic wall material well. It also faithfully simulated the aortic flow and near-wall hemodynamics. The relatively large lumen dimension change (5.4 mm) in a cardiac cycle suggests the necessity of considering wall deformation in aortic flow simulations. We propose employing this approach for future studies, such as medical treatment training, validation of in silico fluid-structure interaction models, or as a complement to in vivo measurements.
Collapse
Affiliation(s)
- Xiaolin Wu
- Department of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Delft, the Netherlands; J. M. Burgerscentrum Research School for Fluid Mechanics, Delft, the Netherlands.
| | - Kaspar M B Jansen
- Department of Sustainable Design Engineering, Delft University of Technology, Delft, the Netherlands
| | - Jos J M Westenberg
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Hildo J Lamb
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Saša Kenjereš
- Department of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Delft, the Netherlands; J. M. Burgerscentrum Research School for Fluid Mechanics, Delft, the Netherlands.
| |
Collapse
|
2
|
Williamson PN, Docherty PD, Jermy M, Steven BM. Literature Survey for In-Vivo Reynolds and Womersley Numbers of Various Arteries and Implications for Compliant In-Vitro Modelling. Cardiovasc Eng Technol 2024; 15:418-430. [PMID: 38499933 PMCID: PMC11319390 DOI: 10.1007/s13239-024-00723-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 02/19/2024] [Indexed: 03/20/2024]
Abstract
PURPOSE In-vitro modelling can be used to investigate haemodynamics of arterial geometry and stent implants. However, in-vitro model fidelity relies on precise matching of in-vivo conditions. In pulsatile flow, velocity distribution and wall shear stress depend on compliance, and the Reynolds and Womersley numbers. However, matching such values may lead to unachievable tolerances in phantom fabrication. METHODS Published Reynolds and Womersley numbers for 14 major arteries in the human body were determined via a literature search. Preference was given to in-vivo publications but in-vitro and in-silico values were presented when in-vivo values were not found. Subsequently ascending aorta and carotid artery case studies were presented to highlight the limitations dynamic matching would apply to phantom fabrication. RESULTS Seven studies reported the in-vivo Reynolds and Womersley numbers for the aorta and two for the carotid artery. However, only one study each reported in-vivo numbers for the remaining ten arteries. No in-vivo data could be found for the femoral, superior mesenteric and renal arteries. Thus, information derived in-vitro and in-silico were provided instead. The ascending aorta and carotid artery models required scaling to 1.5× and 3× life-scale, respectively, to achieve dimensional tolerance restrictions. Modelling the ascending aorta with the comparatively high viscosity water/glycerine solution will lead to high pump power demands. However, all the working fluids considered could be dynamically matched with low pump demand for the carotid model. CONCLUSION This paper compiles available human haemodynamic information, and highlights the paucity of information for some arteries. It also provides a method for optimal in-vitro experimental configuration.
Collapse
Affiliation(s)
- P N Williamson
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, 8140, New Zealand
| | - P D Docherty
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, 8140, New Zealand.
- Institute of Technical Medicine, Furtwangen University, Campus Villingen-Schwenningen, Jakob-Kienzle Strasse 17, 78054, Villingen-Schwenningen, Germany.
| | - M Jermy
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, 8140, New Zealand
| | - B M Steven
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, 8140, New Zealand
| |
Collapse
|
3
|
Shiravand A, Richter K, Willmann P, Eulzer P, Lawonn K, Hundertmark A, Cattaneo G. Fabrication, characterization and numerical validation of a novel thin-wall hydrogel vessel model for cardiovascular research based on a patient-specific stenotic carotid artery bifurcation. Sci Rep 2024; 14:16301. [PMID: 39009618 PMCID: PMC11251049 DOI: 10.1038/s41598-024-66777-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 07/03/2024] [Indexed: 07/17/2024] Open
Abstract
In vitro vascular models, primarily made of silicone, have been utilized for decades for studying hemodynamics and supporting the development of implants for catheter-based treatments of diseases such as stenoses and aneurysms. Hydrogels have emerged as prominent materials in tissue-engineering applications, offering distinct advantages over silicone models for fabricating vascular models owing to their viscoelasticity, low friction, and tunable mechanical properties. Our study evaluated the feasibility of fabricating thin-wall, anatomical vessel models made of polyvinyl alcohol hydrogel (PVA-H) based on a patient-specific carotid artery bifurcation using a combination of 3D printing and molding technologies. The model's geometry, elastic modulus, volumetric compliance, and diameter distensibility were characterized experimentally and numerically simulated. Moreover, a comparison with silicone models with the same anatomy was performed. A PVA-H vessel model was integrated into a mock circulatory loop for a preliminary ultrasound-based assessment of fluid dynamics. The vascular model's geometry was successfully replicated, and the elastic moduli amounted to 0.31 ± 0.007 MPa and 0.29 ± 0.007 MPa for PVA-H and silicone, respectively. Both materials exhibited nearly identical volumetric compliance (0.346 and 0.342% mmHg-1), which was higher compared to numerical simulation (0.248 and 0.290% mmHg-1). The diameter distensibility ranged from 0.09 to 0.20% mmHg-1 in the experiments and between 0.10 and 0.18% mmHg-1 in the numerical model at different positions along the vessel model, highlighting the influence of vessel geometry on local deformation. In conclusion, our study presents a method and provides insights into the manufacturing and mechanical characterization of hydrogel-based thin-wall vessel models, potentially allowing for a combination of fluid dynamics and tissue engineering studies in future cardio- and neurovascular research.
Collapse
Affiliation(s)
- Ashkan Shiravand
- Institute of Biomedical Engineering, University of Stuttgart, Stuttgart, Germany.
| | - Kevin Richter
- Faculty of Natural and Environmental Sciences, University of Kaiserslautern-Landau, Landau, Germany
| | - Pia Willmann
- Institute of Biomedical Engineering, University of Stuttgart, Stuttgart, Germany
| | - Pepe Eulzer
- Faculty of Mathematics and Computer Science, University of Jena, Jena, Germany
| | - Kai Lawonn
- Faculty of Mathematics and Computer Science, University of Jena, Jena, Germany
| | - Anna Hundertmark
- Faculty of Natural and Environmental Sciences, University of Kaiserslautern-Landau, Landau, Germany
| | - Giorgio Cattaneo
- Institute of Biomedical Engineering, University of Stuttgart, Stuttgart, Germany
| |
Collapse
|
4
|
Hazan Shenberger S, Avrahami I. The Effect of Mechanical Circulatory Support on Blood Flow in the Ascending Aorta: A Combined Experimental and Computational Study. Bioengineering (Basel) 2024; 11:238. [PMID: 38534512 DOI: 10.3390/bioengineering11030238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 02/11/2024] [Accepted: 02/22/2024] [Indexed: 03/28/2024] Open
Abstract
Percutaneous mechanical circulatory support (MCS) devices are designed for short-term treatment in cases of acute decompensated heart failure as a bridge to transplant or recovery. Some of the known complications of MCS treatments are related to their hemodynamics in the aorta. The current study investigates the effect of MCS on the aortic flow. The study uses combined experimental and numerical methods to delineate complex flow structures. Particle image velocimetry (PIV) is used to capture the vortical and turbulent flow characteristics in a glass model of the human aorta. Computational fluid dynamics (CFD) analyses are used to complete the 3D flow in the aorta. Three specific MCS configurations are examined: a suction pump with a counterclockwise (CCW) rotating impeller, a suction pump with a clockwise (CW) rotating impeller, and a discharge pump with a straight jet. These models were examined under varying flow rates (1-2.5 L/min). The results show that the pump configuration strongly influences the flow in the thoracic aorta. The rotating impeller of the suction pump induces a dominant swirling flow in the aorta. The swirling flow distributes the incoming jet and reduces the turbulent intensity near the aortic valve and in the aorta. In addition, at high flow rates, the local vortices formed near the pump are washed downstream toward the aortic arch. Specifically, an MCS device with a CCW rotating impeller induces a non-physiological CCW helical flow in the descending aorta (which is opposite to the natural helical flow), while CW swirl combines better with the natural helical flow.
Collapse
Affiliation(s)
- Sapir Hazan Shenberger
- Department of Mechanical Engineering and Mechatronics, Ariel University, Ariel 40700, Israel
| | - Idit Avrahami
- Department of Mechanical Engineering and Mechatronics, Ariel University, Ariel 40700, Israel
| |
Collapse
|
5
|
Zeugin T, Coulter FB, Gülan U, Studart AR, Holzner M. In vitro investigation of the blood flow downstream of a 3D-printed aortic valve. Sci Rep 2024; 14:1572. [PMID: 38238358 PMCID: PMC10796383 DOI: 10.1038/s41598-024-51676-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Accepted: 01/08/2024] [Indexed: 01/22/2024] Open
Abstract
The hemodynamics in the aorta as well as the durability of aortic valve prostheses vary greatly between different types of devices. Although placement and sizing of surgical aortic valve prostheses are excellent, the valve geometry of common devices cannot be customized to fit the patient's anatomy perfectly. Similarly, transcatheter aortic valve implantation (TAVI) devices are not customizable and may be orientated unfavorably during implantation. Imperfect fit of an aortic valve prosthesis may result in suboptimal performance and in some cases the need for additional surgery. Leveraging the advent of precision, multi-material 3D-printing, a bioinspired silicone aortic valve was developed. The manufacturing technique makes it fully customizable and significantly cheaper to develop and produce than common prostheses. In this study, we assess the hemodynamic performance of such a 3D-printed aortic valve and compare it to two TAVI devices as well as to a severely stenosed valve. We investigate the blood flow distal to the valve in an anatomically accurate, compliant aorta model via three-dimensional particle tracking velocimetry measurements. Our results demonstrate that the 3D-printed aortic valve induces flow patterns and topology compatible with the TAVI valves and showing similarity to healthy aortic blood flow. Compared to the stenosis, the 3D-printed aortic valve reduces turbulent kinetic energy levels and irreversible energy losses by over 75%, reaching values compatible with healthy subjects and conventional TAVIs. Our study substantiates that the 3D-printed heart valve displays a hemodynamic performance similar to established devices and underscores its potential for driving innovation towards patient specific valve prostheses.
Collapse
Affiliation(s)
- Till Zeugin
- Department of Civil, Environmental and Geomatic Engineering, Institute of Environmental Engineering, Swiss Federal Institute of Technology ETH Zürich, Zürich, Switzerland.
- Swiss Federal Institute for Forest, Snow and Landscape Research WSL, Birmensdorf, Switzerland.
| | - Fergal B Coulter
- Complex Materials, Swiss Federal Institute of Technology ETH Zürich, Zürich, Switzerland
| | | | - André R Studart
- Complex Materials, Swiss Federal Institute of Technology ETH Zürich, Zürich, Switzerland
| | - Markus Holzner
- Swiss Federal Institute for Forest, Snow and Landscape Research WSL, Birmensdorf, Switzerland
- Swiss Federal Institute for Water Science and Technology EAWAG, Dübendorf, Switzerland
- Institute of Hydraulic Engineering and River Research (IWA), University of Natural Resources and Life Sciences, Vienna, Austria
| |
Collapse
|
6
|
Caridi GCA, Torta E, Mazzi V, Chiastra C, Audenino AL, Morbiducci U, Gallo D. Smartphone-based particle image velocimetry for cardiovascular flows applications: A focus on coronary arteries. Front Bioeng Biotechnol 2022; 10:1011806. [PMID: 36568311 PMCID: PMC9772456 DOI: 10.3389/fbioe.2022.1011806] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Accepted: 11/24/2022] [Indexed: 12/13/2022] Open
Abstract
An experimental set-up is presented for the in vitro characterization of the fluid dynamics in personalized phantoms of healthy and stenosed coronary arteries. The proposed set-up was fine-tuned with the aim of obtaining a compact, flexible, low-cost test-bench for biomedical applications. Technically, velocity vector fields were measured adopting a so-called smart-PIV approach, consisting of a smartphone camera and a low-power continuous laser (30 mW). Experiments were conducted in realistic healthy and stenosed 3D-printed phantoms of left anterior descending coronary artery reconstructed from angiographic images. Time resolved image acquisition was made possible by the combination of the image acquisition frame rate of last generation commercial smartphones and the flow regimes characterizing coronary hemodynamics (velocities in the order of 10 cm/s). Different flow regimes (Reynolds numbers ranging from 20 to 200) were analyzed. The smart-PIV approach was able to provide both qualitative flow visualizations and quantitative results. A comparison between smart-PIV and conventional PIV (i.e., the gold-standard experimental technique for bioflows characterization) measurements showed a good agreement in the measured velocity vector fields for both the healthy and the stenosed coronary phantoms. Displacement errors and uncertainties, estimated by applying the particle disparity method, confirmed the soundness of the proposed smart-PIV approach, as their values fell within the same range for both smart and conventional PIV measured data (≈5% for the normalized estimated displacement error and below 1.2 pixels for displacement uncertainty). In conclusion, smart-PIV represents an easy-to-implement, low-cost methodology for obtaining an adequately robust experimental characterization of cardiovascular flows. The proposed approach, to be intended as a proof of concept, candidates to become an easy-to-handle test bench suitable for use also outside of research labs, e.g., for educational or industrial purposes, or as first-line investigation to direct and guide subsequent conventional PIV measurements.
Collapse
|
7
|
Williamson PN, Docherty PD, Yazdi SG, Khanafer A, Kabaliuk N, Jermy M, Geoghegan PH. Review of the Development of Hemodynamic Modeling Techniques to Capture Flow Behavior in Arteries Affected by Aneurysm, Atherosclerosis, and Stenting. J Biomech Eng 2022; 144:1128816. [PMID: 34802061 DOI: 10.1115/1.4053082] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Indexed: 02/05/2023]
Abstract
Cardiovascular diseases (CVDs) are the leading cause of death in the developed world. CVD can include atherosclerosis, aneurysm, dissection, or occlusion of the main arteries. Many CVDs are caused by unhealthy hemodynamics. Some CVDs can be treated with the implantation of stents and stent grafts. Investigations have been carried out to understand the effects of stents and stent grafts have on arteries and the hemodynamic changes post-treatment. Numerous studies on stent hemodynamics have been carried out using computational fluid dynamics (CFD) which has yielded significant insight into the effect of stent mesh design on near-wall blood flow and improving hemodynamics. Particle image velocimetry (PIV) has also been used to capture behavior of fluids that mimic physiological hemodynamics. However, PIV studies have largely been restricted to unstented models or intra-aneurysmal flow rather than peri or distal stent flow behaviors. PIV has been used both as a standalone measurement method and as a comparison to validate the CFD studies. This article reviews the successes and limitations of CFD and PIV-based modeling methods used to investigate the hemodynamic effects of stents. The review includes an overview of physiology and relevant mechanics of arteries as well as consideration of boundary conditions and the working fluids used to simulate blood for each modeling method along with the benefits and limitations introduced.
Collapse
Affiliation(s)
- Petra N Williamson
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Paul D Docherty
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Sina G Yazdi
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Adib Khanafer
- Vascular, Endovascular, and Renal Transplant Unit, Christchurch Hospital, Canterbury District Health Board, Riccarton Avenue, Christchurch 8053, New Zealand; Christchurch School of Medicine, University of Otago, Dunedin 9016, New Zealand
| | - Natalia Kabaliuk
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Mark Jermy
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Patrick H Geoghegan
- School of Life and Health Sciences, Aston University, Birmingham B4 7ET, UK; Department of Mechanical and Industrial Engineering, University of South Africa, Johannesburg 2006, South Africa
| |
Collapse
|
8
|
Rosakis A, Gharib M. The Influence of Valve Leaflet Stiffness Variability on Aortic Wall Shear Stress. Ann Biomed Eng 2022; 50:29-38. [PMID: 34993697 DOI: 10.1007/s10439-021-02899-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 12/01/2021] [Indexed: 11/30/2022]
Abstract
Aortic stenosis is a common cardiac condition that impacts the aorta's hemodynamics downstream of the affected valve. We sought to better understand how non-uniform stiffening of a stenotic aortic valve would affect the wall shear stress (WSS) experienced by the walls of the aorta and the residence time near the valve. Several experimental configurations were created by individually stiffening leaflets of a polymer aortic valve. These configurations were mounted inside an in vitro experimental setup. Digital particle image velocimetry (DPIV) was used to measure velocity profiles inside a model aorta. The DPIV results were used to estimate the WSS and residence time. Our analysis suggests that leaflet asymmetry greatly affects the amount of WSS by vectoring the systolic jet and stiffened leaflets have an increased residence time. This study indicates that valve leaflets with different stiffness conditions can have a more significant impact on wall shear stress than stenosis caused by the uniform increase in all three leaflets (and the subsequent increased systolic velocity) alone. This finding is promising for creating customizable (patient-specific) prosthetic heart valves tailored to individual patients.
Collapse
Affiliation(s)
| | - Morteza Gharib
- Caltech, 1200 E California Blvd, MC 105-50, Pasadena, CA, 91125, USA
| |
Collapse
|
9
|
Moravia A, Simoëns S, El Hajem M, Bou-Saïd B, Kulisa P, Della-Schiava N, Lermusiaux P. In vitro flow study in a compliant abdominal aorta phantom with a non-Newtonian blood-mimicking fluid. J Biomech 2021; 130:110899. [PMID: 34923186 DOI: 10.1016/j.jbiomech.2021.110899] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 12/02/2021] [Accepted: 12/02/2021] [Indexed: 10/19/2022]
Abstract
In vitro aortic flow simulators allow studying hemodynamics with a wider range of flow visualization techniques compared to in vivo medical imaging and without the limitations of invasive examinations. This work aims to develop an experimental bench to emulate the pulsatile circulation in a realistic aortic phantom. To mimic the blood shear thinning behavior, a non-Newtonian aqueous solution is prepared with glycerin and xanthan gum polymer. The flow is compared to a reference flow of Newtonian fluid. Particle image velocimetry is carried out to visualize 2D velocity fields in a phantom section. The experimental loop accurately recreates flowrates and pressure conditions and preserves the shear-thinning properties of the non-Newtonian fluid. Velocity profiles, shear rate, and shear stress distribution maps show that the Newtonian fluid tends to dampen the observed velocities. Preferential asymmetrical flow paths are observed in a diameter narrowing region and amplified in the non-Newtonian case. Wall shear stresses are about twice higher in the non-Newtonian case. This study shows new insights on flow patterns, velocity and shear stress distributions compared to rigid and simplified geometry aorta phantom with Newtonian fluid flows studies. The use of a non-Newtonian blood analog shows clear differences in flows compared to the Newtonian one in this compliant patient-specific geometry. The development of this aortic simulator is a promising tool to better analyze and understand aortic hemodynamics and to aid in clinical decision-making.
Collapse
Affiliation(s)
- Anaïs Moravia
- Université de Lyon, INSA de Lyon, Ecole Centrale de Lyon, Université Claude Bernard Lyon 1, CNRS, LMFA UMR 5509, Villeurbanne, France.
| | - Serge Simoëns
- Université de Lyon, INSA de Lyon, Ecole Centrale de Lyon, Université Claude Bernard Lyon 1, CNRS, LMFA UMR 5509, Villeurbanne, France
| | - Mahmoud El Hajem
- Université de Lyon, INSA de Lyon, Ecole Centrale de Lyon, Université Claude Bernard Lyon 1, CNRS, LMFA UMR 5509, Villeurbanne, France
| | - Benyebka Bou-Saïd
- Université de Lyon, CNRS, INSA de Lyon, LaMCoS UMR5259, Villeurbanne, France
| | - Pascale Kulisa
- Université de Lyon, INSA de Lyon, Ecole Centrale de Lyon, Université Claude Bernard Lyon 1, CNRS, LMFA UMR 5509, Villeurbanne, France
| | | | - Patrick Lermusiaux
- Vascular and Endovascular Department, Hospices Civils de Lyon, Lyon, France
| |
Collapse
|
10
|
Yazdi SG, Docherty PD, Williamson PN, Jermy M, Kabaliuk N, Khanafer A, Geoghegan PH. In vitro pulsatile flow study in compliant and rigid ascending aorta phantoms by stereo particle image velocimetry. Med Eng Phys 2021; 96:81-90. [PMID: 34565556 DOI: 10.1016/j.medengphy.2021.08.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 08/05/2021] [Accepted: 08/31/2021] [Indexed: 10/20/2022]
Abstract
The aorta is a high risk region for cardiovascular disease (CVD). Haemodynamic patterns leading to CVD are not well established despite numerous experimental and numerical studies. Most overlook effects of arterial compliance and pulsatile flow. However, rigid wall assumptions can lead to overestimation of wall shear stress; a key CVD determinant. This work investigates the effect of compliance on aortic arch haemodynamics experiencing pulsatility. Rigid and compliant phantoms of the arch and brachiocephalic branch (BCA) were manufactured. Stereoscopic particle image velocimetry was used to observe velocity fields. Higher velocity magnitude was observed in the rigid BCA during acceleration. However, during deceleration, the compliant phantom experienced higher velocity. During deceleration, a low velocity region initiated and increased in size in the BCA of both phantoms with irregular shape in the compliant. At mid-deceleration, considerably larger recirculation was observed under compliance compared to rigid. Another recirculation region formed and increased in size on the inner wall of the arch in the compliant during late deceleration, but not rigid. The recirculation regions witnessed identify as high risk areas for atherosclerosis formation by a previous ex-vivo study. The results demonstrate necessity of compliance and pulsatility in haemodynamic studies to obtain highly relevant clinical outcomes.
Collapse
Affiliation(s)
- Sina G Yazdi
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand
| | - Paul D Docherty
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand
| | - Petra N Williamson
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand
| | - Mark Jermy
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand
| | - Natalia Kabaliuk
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand
| | - Adib Khanafer
- Vascular, Endovascular, & Renal Transplant Unit Christchurch Hospital, Canterbury District Health Board, Riccarton Avenue, Christchurch 8053, New Zealand; Christchurch School of Medicine, University of Otago, New Zealand
| | - Patrick H Geoghegan
- Department of Mechanical, Biomedical and Design, College of Engineering and Physical Sciences Aston University, Birmingham, B4 7ET, England; Department of Mechanical and Industrial Engineering, University of South Africa, Johannesburg, South Africa.
| |
Collapse
|
11
|
Williamson PN, Docherty PD, Yazdi SG, Khanafer A, Kabaliuk N, Jermy M. PIV Analysis of Haemodynamics Distal to the Frozen Elephant Trunk Stent Surrogate. Cardiovasc Eng Technol 2021; 12:373-386. [PMID: 33675018 DOI: 10.1007/s13239-021-00521-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 01/13/2021] [Indexed: 11/30/2022]
Abstract
PURPOSE The Frozen Elephant Trunk (FET) stent is a hybrid endovascular device that may be implemented in the event of an aneurysm or aortic dissection of the aortic arch or superior descending aorta. A Type 1B endoleak can lead to intrasaccular flow during systole and has been identified as a known failure of the FET stent graft. The purpose was to develop in-vitro modelling techniques to enable the investigation of the known failure. METHODS A silicone aortic phantom and 3D printed surrogate stent graft were manufactured to investigate the haemodynamics of a Type 1B endoleak. Physiological pulsatile flow dynamics distal to the surrogate stent graft were investigated in-vitro using Particle Image Velocimetry (PIV). RESULTS PIV captured recirculation zones and an endoleak distal to the surrogate stent graft. The endoleak was developed at the peak of systole and sustained until the onset of diastole. The endoleak was asymmetric, indicating a potential variation in the phantom artery wall thickness or stent alignment. Recirculation was identified on the posterior dorsal line during late systole. CONCLUSIONS The identification of the Type 1B endoleak proved that in-vitro modelling can be used to investigate complex compliance changes and wall motions. The recirculation may indicate the potential for long term intimal layer inflammatory issues such as atherosclerosis. These results may aid future remediation techniques or stent design. Further development of the methods used in this experiment may assist with the future testing of stents prior to animal or human trial.
Collapse
Affiliation(s)
- Petra N Williamson
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, 8041, New Zealand
| | - Paul D Docherty
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, 8041, New Zealand. .,Institute of Technical Medicine, Furtwangen University, Campus Villingen-Schwenningen, Jakob-Kienzle Strasse 17, 78054, Villingen-Schwenningen, Germany.
| | - Sina G Yazdi
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, 8041, New Zealand
| | - Adib Khanafer
- Vascular, Endovascular & Renal Transplant Unit, Christchurch Hospital, Canterbury District Health Board, Riccarton Avenue, Christchurch, 8053, New Zealand.,Christchurch School of Medicine, University of Otago, Dunedin, New Zealand
| | - Natalia Kabaliuk
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, 8041, New Zealand
| | - Mark Jermy
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch, 8041, New Zealand
| |
Collapse
|
12
|
A Brush-Spin-Coating Method for Fabricating In Vitro Patient-Specific Vascular Models by Coupling 3D-Printing. Cardiovasc Eng Technol 2020; 12:200-214. [PMID: 33263929 DOI: 10.1007/s13239-020-00504-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Accepted: 11/18/2020] [Indexed: 12/31/2022]
Abstract
PURPOSE In vitro patient-specific flexible vascular models are helpful for understanding the haemodynamic changes before and after endovascular treatment and for effective training of neuroendovascular interventionalists. However, it is difficult to fabricate models of overall unified or controllable thickness using existing manufacturing methods. In this study, we developed an improved and easily implemented method by combining 3D printing and brush-spin-coating processes to produce a transparent silicone model of uniform or varied thickness. METHODS First, a water-soluble inner-skeleton model, based on clinical data, was printed on a 3D printer. The skeleton model was subsequently fixed in a single-axis-rotation machine to enable continuous coating of silicone, the thickness of which was manually controlled by adsorption and removal of excess silicone in a brush-spinning operation. After the silicone layer was solidified, the inner skeleton was further dissolved in a hot water bath, affording a transparent vascular model with real geometry. To verify the controllability of the coating thickness by using this method, a straight tube, an idealised aneurysm model, a patient-specific aortic arch model, and an abdominal aortic aneurysm model were manufactured. RESULTS The different thicknesses of the manufactured tubes could be well controlled, with the relative standard deviations being 5.6 and 8.1% for the straight and aneurysm tubes, respectively. Despite of the diameter changing from 33 to 20 mm in the patient-specific aorta, the thickness of the fabricated aortic model remains almost the same along the longitudinal direction with a lower standard deviation of 3.1%. In the more complex patient-specific abdominal aneurysm model, varied thicknesses were realized to mimic the measured data from the CT images, where the middle of the aneurysm was with 2 mm and abdominal aorta as well as the iliac arteries had the normal thickness of 2.3 mm. CONCLUSION Through the brush-spin-coating method, models of different sizes and complexity with prescribed thickness can be manufactured, which will be helpful for developing surgical treatment strategies or training neuroendovascular interventionalists.
Collapse
|
13
|
Li Y, Yoneyama Y, Isoda H, Terada M, Kosugi T, Kosugi T, Zhang M, Ohta M. Haemodynamics in a patient-specific intracranial aneurysm according to experimental and numerical approaches: A comparison of PIV, CFD and PC-MRI. Technol Health Care 2020; 29:253-267. [PMID: 32568138 DOI: 10.3233/thc-202252] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The haemodynamics determined by different approaches for studying fluid dynamics - i.e. computational fluid dynamics (CFD), particle image velocimetry (PIV), and phase-contrast magnetic resonance imaging (PC-MRI) - have rarely been thoroughly compared; nor have the factors that affect accuracy and precision in each method. As each method has its own advantages and limitations, this knowledge is important for future studies to be able to achieve valid analyses of fluid flows. OBJECTIVE To gauge the capacity of these methods for analysing aneurysmal flows, we compared the haemodynamic behaviours determined by each method within a patient-specific aneurysm model. METHODS An in vitro silicone aneurysm model was fabricated for PIV and PC-MRI, and an in silico aneurysm model with the same geometry was reconstructed for CFD. With the same fluid model prepared numerically and physically, CFD, PIV and PC-MRI were performed to study aneurysmal haemodynamics. RESULTS 2D velocity vectors and magnitudes show good agreement between PIV and CFD, and 3D flow patterns show good similarity between PC-MRI and CFD. CONCLUSIONS These findings give confidence to future haemodynamic studies using CFD technology. For the first time, the morphological inconsistency between the PCMRI model and others is found to affect the measurement of local flow patterns.
Collapse
Affiliation(s)
- Yujie Li
- Institute of Fluid Science, Tohoku University, Sendai, Miyagi, Japan
| | - Yuuya Yoneyama
- Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan.,Department of Radiology, Fujita Health University Hospital, Toyoake, Aichi, Japan
| | - Haruo Isoda
- Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan.,Brain and Mind Research Center, Nagoya University, Nagoya, Aichi, Japan
| | - Masaki Terada
- Department of Diagnostic Radiological Technology, Iwata City Hospital, Iwata, Shizuoka, Japan
| | - Takafumi Kosugi
- Renaissance of Technology Corporation, Hamamatsu, Shizuoka, Japan
| | - Takashi Kosugi
- Renaissance of Technology Corporation, Hamamatsu, Shizuoka, Japan
| | - Mingzi Zhang
- Institute of Fluid Science, Tohoku University, Sendai, Miyagi, Japan
| | - Makoto Ohta
- Institute of Fluid Science, Tohoku University, Sendai, Miyagi, Japan
| |
Collapse
|
14
|
Williamson P, Docherty PD, Yazdi SG, Jermy M, Khanafer A, Kabaliuk N, Geoghegan PH. PIV Analysis of Stented Haemodynamics in the Descending Aorta. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:4737-4740. [PMID: 31946920 DOI: 10.1109/embc.2019.8856823] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Cardiovascular diseases (CVD) are the leading cause of death in the developed world and aortic aneurysm is a key contributor. Aortic aneurysms typically occur in the thoracic aorta and can extend into the descending aorta. The Frozen Elephant Trunk stent (FET) is one of the leading treatments for the aneurysms extending into the descending aorta. This study focuses on the in-vitro experimentation of a stented descending aorta, investigating the haemodynamics in a compliant phantom. A silicone phantom of the descending aorta was manufactured using a lost core casting method. A PVC stent was manufactured using the same mould core. Particle Image Velocimetry (PIV) was used for pulsatile studies, focusing specifically on the passive fixation at the distal end of the FET. The results showed an apparent expansion in the diastolic period that was identified to be a collapse in the lateral plane. Flow recirculation regions were identified during the collapse. The collapse was attributed to low upstream and high downstream pressures causing a vacuum effect. The findings may imply a potential risk introduced by the FET stent that requires further investigation.
Collapse
|
15
|
Gross-Hardt SH, Sonntag SJ, Boehning F, Steinseifer U, Schmitz-Rode T, Kaufmann TA. Crucial Aspects for Using Computational Fluid Dynamics as a Predictive Evaluation Tool for Blood Pumps. ASAIO J 2019; 65:864-873. [DOI: 10.1097/mat.0000000000001023] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
16
|
A Novel Fabrication Method for Compliant Silicone Phantoms of Arterial Geometry for Use in Particle Image Velocimetry of Haemodynamics. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9183811] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Cardiovascular diseases (CVDs) are one of the leading causes of death globally. In-vitro measurement of blood flow in compliant arterial phantoms can provide better insight into haemodynamic states and therapeutic procedures. However, current fabrication techniques are not capable of producing thin-walled compliant phantoms of complex shapes. This study presents a new approach for the fabrication of compliant phantoms suitable for optical measurement. Two 1.5× scaled models of the ascending aorta, including the brachiocephalic artery (BCA), were fabricated from silicone elastomer Sylgard-184. The initial phantom used the existing state of the art lost core manufacturing technique with simple end supports, an acrylonitrile butadiene styrene (ABS) additive manufactured male mould and Ebalta-milled female mould. The second phantom was produced with the same method but used more rigid end supports and ABS male and female moulds. The wall thickness consistency and quality of resulting stereoscopic particle image velocimetry (SPIV) were used to verify the fidelity of the phantom for optical measurement and investigation of physiological flow fields. However, the initial phantom had a rough surface that obscured SPIV analysis and had a variable wall thickness (range = 0.815 mm). The second phantom provided clear particle images and had a less variable wall thickness (range = 0.317 mm). The manufacturing method developed is suitable for fast and cost-effective fabrication of different compliant arterial phantom geometries.
Collapse
|