1
|
Andersson P, Swanpalmer J, Palm Å, Båth M, Chakarova R. Cylindrical ionization chamber response in static and dynamic 6 and 15 MV photon beams. Biomed Phys Eng Express 2023; 9. [PMID: 36689763 DOI: 10.1088/2057-1976/acb553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 01/23/2023] [Indexed: 01/24/2023]
Abstract
Purpose.To investigate the response of the CC13 ionization chamber under non-reference photon beam conditions, focusing on penumbra and build-up regions of static fields and on dynamic intensity-modulated beams.Methods. Measurements were performed in 6 MV 100 × 100, 20 × 100, and 20 × 20 mm2static fields. Monte Carlo calculations were performed for the static fields and for 6 and 15 MV dynamic beam sequences using a Varian multi-leaf collimator. The chamber was modelled using EGSnrc egs_chamber software. Conversion factors were calculated by relating the absorbed dose to air in the chamber air cavity to the absorbed dose to water. Correction and point-dose correction factors were calculated to quantify the conversion factor variations.Results. The correction factors for positions on the beam central axis and at the penumbra centre were 0.98-1.02 for all static fields and depths investigated. The largest corrections were obtained for chamber positions beyond penumbra centre in the off-axis direction. Point-dose correction factors were 0.54-0.71 at 100 mm depth and their magnitude increased with decreasing field size and measurement depth. Factors of 0.99-1.03 were obtained inside and near the integrated penumbra of the dynamic field at 100 mm depth, and of 0.92-0.94 beyond the integrated penumbra centre. The variations in the ionization chamber response across the integrated dynamic penumbra qualitatively followed the behaviour across penumbra of static fields.Conclusions. Without corrections, the CC13 chamber was of limited usefulness for profile measurements in 20-mm-wide fields. However, measurements in dynamic small irregular beam openings resembling the conditions of pre-treatment patient quality assurance were feasible. Uncorrected ionization chamber response could be applied for dose verification at 100 mm depth inside and close to large gradients of dynamically accumulating high- and low-dose regions assuming 3% tolerance between measured and calculated doses.
Collapse
Affiliation(s)
- P Andersson
- Sahlgrenska Academy, Institute of Clinical Sciences, Department of Medical Radiation Sciences, University of Gothenburg, Gothenburg, Sweden.,RISE Research Institutes of Sweden, Materials and Production, Gothenburg, Sweden
| | - J Swanpalmer
- Sahlgrenska Academy, Institute of Clinical Sciences, Department of Medical Radiation Sciences, University of Gothenburg, Gothenburg, Sweden.,Sahlgrenska University Hospital, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Å Palm
- Sahlgrenska University Hospital, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - M Båth
- Sahlgrenska Academy, Institute of Clinical Sciences, Department of Medical Radiation Sciences, University of Gothenburg, Gothenburg, Sweden.,Sahlgrenska University Hospital, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - R Chakarova
- Sahlgrenska Academy, Institute of Clinical Sciences, Department of Medical Radiation Sciences, University of Gothenburg, Gothenburg, Sweden.,Sahlgrenska University Hospital, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| |
Collapse
|
2
|
Yousif YAM, Gastaldo J, Baldock C. Golden beam data provided by linear accelerator manufacturers should be used in the commissioning of treatment planning systems. Phys Eng Sci Med 2022; 45:407-411. [PMID: 35604544 PMCID: PMC9125535 DOI: 10.1007/s13246-022-01134-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Yousif A M Yousif
- North West Cancer Centre, Tamworth Hospital, 2340, Tamworth, NSW, Australia
| | - Jerome Gastaldo
- St George's Cancer Care Centre, 8140, Christchurch, New Zealand
| | - Clive Baldock
- Graduate Research School, Western Sydney University, 2747, Penrith, NSW, Australia.
| |
Collapse
|