Shah VN, Akturk HK, Joseph H, Schneider N, Snell-Bergeon JK. A randomized controlled trial of transition from insulin pump to multiple daily injections using insulin degludec.
Diabetes Obes Metab 2021;
23:1936-1941. [PMID:
34180122 DOI:
10.1111/dom.14423]
[Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 04/22/2021] [Accepted: 05/03/2021] [Indexed: 12/01/2022]
Abstract
AIM
To evaluate two methods of transition from an insulin pump to multiple daily injections (MDI) using long-acting insulin degludec (IDeg).
MATERIALS AND METHODS
After a 1-week run-in period, adults with type 1 diabetes for longer than 1 year and HbA1c 48-69 mmol/mol (6.5%-8.5%), who had been using an insulin pump at least for 6 months, were randomly transitioned to either standard of care (discontinued insulin pump and started IDeg in 1:1 dose) or overlap (IDeg 1:1 at pump basal dose, but pump continued for the first 48 hours with a gradual basal reduction; 50% from 0-24 hours, 75% from 24-48 hours and then pump discontinued). Participants used blinded Dexcom G6 and the IDeg dose was not changed during the trial. Primary (% time above 180 mg/dL) and secondary (% time in 70-180 mg/dL and below 70 mg/dL) outcomes were compared between the two groups during 7 days of randomization.
RESULTS
Age, gender, diabetes duration and basal/bolus insulin doses were similar between patients randomized to standard of care (n = 17) or overlap (n = 13) transition. Compared with overlap transition, the standard of care group spent 4.8% more time in hyperglycaemia (least square mean 4.8% [95% CI -3.3%, 12.9%]) and 5.3% less time in range (-5.3% [-12.6%, -2.0%]), without a significant difference in hypoglycaemia (0.5% [-2.3%,3.4%]). No treatment-related adverse events were noted in either group.
CONCLUSION
The overlap transition method may result in a significant improvement in time-in-range without increasing hypoglycaemia during the first week of transition from an insulin pump to MDI using IDeg in adults with type 1 diabetes.