1
|
Cuervo L, Méndez C, Olano C, Malmierca MG. Volatilome: Smells like microbial spirit. ADVANCES IN APPLIED MICROBIOLOGY 2024; 127:1-43. [PMID: 38763526 DOI: 10.1016/bs.aambs.2024.02.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2024]
Abstract
In recent years, the study of volatile compounds has sparked interest due to their implications in signaling and the enormous variety of bioactive properties attributed to them. Despite the absence of analysis methods standardization, there are a multitude of tools and databases that allow the identification and quantification of volatile compounds. These compounds are chemically heterogeneous and their diverse properties are exploited by various fields such as cosmetics, the food industry, agriculture and medicine, some of which will be discussed here. In virtue of volatile compounds being ubiquitous and fast chemical messengers, these molecules mediate a large number of interspecific and intraspecific interactions, which are key at an ecological level to maintaining the balance and correct functioning of ecosystems. This review briefly summarized the role of volatile compounds in inter- and intra-specific relationships as well as industrial applications associated with the use of these compounds that is emerging as a promising field of study.
Collapse
Affiliation(s)
- Lorena Cuervo
- Functional Biology Department, University of Oviedo, Oviedo, Spain; University Institute of Oncology of Asturias, University of Oviedo, Oviedo, Spain; Health Research Institute of Asturias, Av. del Hospital Universitario, s/n, Oviedo, Spain
| | - Carmen Méndez
- Functional Biology Department, University of Oviedo, Oviedo, Spain; University Institute of Oncology of Asturias, University of Oviedo, Oviedo, Spain; Health Research Institute of Asturias, Av. del Hospital Universitario, s/n, Oviedo, Spain
| | - Carlos Olano
- Functional Biology Department, University of Oviedo, Oviedo, Spain; University Institute of Oncology of Asturias, University of Oviedo, Oviedo, Spain; Health Research Institute of Asturias, Av. del Hospital Universitario, s/n, Oviedo, Spain
| | - Mónica G Malmierca
- Functional Biology Department, University of Oviedo, Oviedo, Spain; University Institute of Oncology of Asturias, University of Oviedo, Oviedo, Spain; Health Research Institute of Asturias, Av. del Hospital Universitario, s/n, Oviedo, Spain.
| |
Collapse
|
2
|
Li J, Li M, Liu R, Guo Y, Yang D, Hou K. A homogeneous sampling membrane inlet photoelectron ionization miniature time-of-flight mass spectrometer for on-line determination of ethane. Talanta 2024; 267:125221. [PMID: 37742395 DOI: 10.1016/j.talanta.2023.125221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Revised: 09/10/2023] [Accepted: 09/16/2023] [Indexed: 09/26/2023]
Abstract
Ethane is the second largest component among natural gas, and the detection of ethane is an effective method for rapid identification of the leakage of the natural gas pipelines. In this work, a homogeneous sampling membrane inlet was developed and coupled with the homemade photoelectron ionization miniature time-of-flight mass spectrometer (PEI-mini-TOFMS) for in situ, on-line and highly sensitive ethane detection. The membrane area of the homogeneous sampling membrane inlet was increased from 490 mm2 to 1256 mm2, gaseous sample is injected from the top port and flowed through the membrane surface and out of the bottom two ports, with the three ports arranged in a triangular shape. The highest average flow velocity of the gas on the surface of the membrane reached 0.4 m s-1, and the optimal gas pressure in the PEI source was enhanced from 2.2 Pa to 4.0 Pa with this new design. The new design improved the comprehensive sensitivity of ethane by a factor of 3.0 compared with that of the traditional two-hole membrane inlet with the membrane area of 490 mm2. The semiconductor cold trap controlled the sample relative humidity (RH) at 10-12%, enabling direct sampling for highly sensitive analysis with RH as high as 70% and temperature from 7 °C to 40 °C. The quantitative range was 1-50 ppmv with a limit of detection (LOD, S/N = 3) lowered to 420 ppbv within 1 min, and zero humidity quantitative calibration with cold trap further reduced the relative standard deviation (RSD) of the signal intensities to 2.84%. The performance of the novel method developed in this work demonstrated a potential application on the above-ground natural gas pipelines leakage monitoring.
Collapse
Affiliation(s)
- Jing Li
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao, 266237, China
| | - Mei Li
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao, 266237, China.
| | - Ruidong Liu
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao, 266237, China
| | - Yingzhe Guo
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao, 266237, China
| | - Dong Yang
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao, 266237, China
| | - Keyong Hou
- Environment Research Institute, Shandong University, 72 Binhai Road, Qingdao, 266237, China.
| |
Collapse
|
3
|
Feng C, Liu S, Jiang T, Xu W. Multiplexing Quadrupole and Ion Trap Operation Modes on a "Brick" Miniature Mass Spectrometer. Molecules 2023; 28:7640. [PMID: 38005361 PMCID: PMC10674918 DOI: 10.3390/molecules28227640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 10/26/2023] [Accepted: 11/10/2023] [Indexed: 11/26/2023] Open
Abstract
Although a quadruple mass analyzer and an ion trap mass analyzer have complementary analytical features, they usually have different geometries, operational modes, and electronic control systems. As a continuous effort to extend its coverage, both quadrupole and ion trap operation modes were realized on a "brick" miniature mass spectrometer with a single mass analyzer. In the quadrupole operation mode, low-mass ions ranging from 31 to 502 Th can be analyzed. On the other hand, the ion trap mode can be utilized to cover ions with higher mass to charge ratios (up to 922 Th), as well as performing tandem mass spectrometry. To realize the multiplexing of both operation modes, a printed circuit board (PCB)-based multi-electrode quadrupole-ion trap mass analyzer was designed and integrated in the system. To cover both volatile and non-volatile molecules, two ionization sources were also implemented, including a nano electrospray ionization source and an in-vacuum plasma ionization source. Performances of the instrument operated in these two modes were characterized, such as mass resolution, sensitivity, and mass range. Results demonstrate that the combination of the quadrupole and ion trap operation modes can provide new capabilities when solving analytical problems.
Collapse
Affiliation(s)
| | | | - Ting Jiang
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China; (C.F.); (S.L.)
| | - Wei Xu
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China; (C.F.); (S.L.)
| |
Collapse
|
4
|
Condensed Phase Membrane Introduction Mass Spectrometry: A Direct Alternative to Fully Exploit the Mass Spectrometry Potential in Environmental Sample Analysis. SEPARATIONS 2023. [DOI: 10.3390/separations10020139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023] Open
Abstract
Membrane introduction mass spectrometry (MIMS) is a direct mass spectrometry technique used to monitor online chemical systems or quickly quantify trace levels of different groups of compounds in complex matrices without extensive sample preparation steps and chromatographic separation. MIMS utilizes a thin, semi-permeable, and selective membrane that directly connects the sample and the mass spectrometer. The analytes in the sample are pre-concentrated by the membrane depending on their physicochemical properties and directly transferred, using different acceptor phases (gas, liquid or vacuum) to the mass spectrometer. Condensed phase (CP) MIMS use a liquid as a medium, extending the range to new applications to less-volatile compounds that are challenging or unsuitable to gas-phase MIMS. It directly allows the rapid quantification of selected compounds in complex matrices, the online monitoring of chemical reactions (in real-time), as well as in situ measurements. CP-MIMS has expanded beyond the measurement of several organic compounds because of the use of different types of liquid acceptor phases, geometries, dimensions, and mass spectrometers. This review surveys advancements of CP-MIMS and its applications to several molecules and matrices over the past 15 years.
Collapse
|
5
|
Wang J, Pursell ME, DeVor A, Awoyemi O, Valentine SJ, Li P. Portable mass spectrometry system: instrumentation, applications, and path to 'omics analysis. Proteomics 2022; 22:e2200112. [PMID: 36349734 PMCID: PMC10278091 DOI: 10.1002/pmic.202200112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 10/27/2022] [Accepted: 10/28/2022] [Indexed: 11/11/2022]
Abstract
Mass spectrometry (MS) is an information rich analytical technique and plays a key role in various 'omics studies. Standard mass spectrometers are bulky and operate at high vacuum, which hinder their adoption by the broader community and utility in field applications. Developing portable mass spectrometers can significantly expand the application scope and user groups of MS analysis. This review discusses the basics and recent advancements in the development of key components of portable mass spectrometers including ionization source, mass analyzer, detector, and vacuum system. Further, major areas where portable mass spectrometers are applied are also discussed. Finally, a perspective on the further development of portable mass spectrometers including the potential benefits for 'omics analysis is provided.
Collapse
Affiliation(s)
- Jing Wang
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Madison E. Pursell
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Amanda DeVor
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Olanrewaju Awoyemi
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Stephen J. Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| |
Collapse
|
6
|
Evans-Nguyen K, Stelmack AR, Clowser PC, Holtz JM, Mulligan CC. FIELDABLE MASS SPECTROMETRY FOR FORENSIC SCIENCE, HOMELAND SECURITY, AND DEFENSE APPLICATIONS. MASS SPECTROMETRY REVIEWS 2021; 40:628-646. [PMID: 32722885 DOI: 10.1002/mas.21646] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Accepted: 02/24/2020] [Indexed: 05/26/2023]
Abstract
Mass spectrometry is commonly used in forensic chemistry laboratories for sensitive, definitive analysis. There have been significant efforts to bring mass spectrometry analysis on-site through the development of ruggedized, fieldable instruments. Testing samples in the field is of particular interest in forensic science, homeland security, and defense applications. In forensic chemistry, testing seized drugs in the field can significantly improve efficiencies in processing of related criminal cases. The screening of passengers and luggage at transportation hubs is a critical need for homeland security for which mass spectrometry is well suited to provide definitive answers with low false positive rates. Mass spectrometry can yield reliable data for military personnel testing sites for potential chemical weapons release. To meet the needs of the forensic and security communities fieldable mass spectrometers based on membrane inlet systems and hybrid gas chromatography systems have been developed and commercialized. More recently developed ambient ionization mass spectrometry methods can eliminate the time, equipment, and expertise associated with sample preparation, and so are especially appealing for on-site analysis. We describe the development of fieldable mass spectrometry systems, with emphasis on commercially available systems that have been deployed for on-site analysis of seized drugs, chemical warfare agents, explosives, and other analytes of interest to the forensic and security communities. © 2020 John Wiley & Sons Ltd. Mass Spec Rev.
Collapse
Affiliation(s)
- Kenyon Evans-Nguyen
- Department of Chemistry, Biochemistry and Physics, University of Tampa, Tampa, FL
| | | | | | - Jessica M Holtz
- Department of Chemistry, Illinois State University, Normal, IL
| | | |
Collapse
|
7
|
Yu Z, Li Y. Marine volatile organic compounds and their impacts on marine aerosol-A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 768:145054. [PMID: 33736323 DOI: 10.1016/j.scitotenv.2021.145054] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Revised: 01/04/2021] [Accepted: 01/06/2021] [Indexed: 06/12/2023]
Abstract
Volatile organic compounds (VOCs) play a vital role in the global carbon budget and in the regional formation of ozone in the troposphere, and are emitted from both natural and anthropogenic activities. They can also serve as a source of secondary organic aerosol (SOA). Field and model studies showed evidences of a strong marine biogenic influence on marine aerosols. Although knowledge of terrestrial VOC emissions and SOA formation mechanisms has been advanced considerably over the last decades, processes constraining marine VOC emissions and marine SOA formation remain poorly understood. Seawater contains an extremely complex, diverse, and largely unidentified mixture of VOCs. Despite the fact that the ocean covers 70% of the Earth's surface, the role of the ocean in the global budget of VOCs is still unclear. The distribution and emission of sea surface VOCs exhibit considerable spatial-temporal variation, with higher concentrations often, but not always, correlated with biological activities. VOCs in surface seawater have been measured in various geographic regions, however, knowledge of the distribution of marine VOCs and the role of the oceans in the global atmospheric chemistry is still insufficient due to the paucity of measurements. This study reviews marine VOCs in terms of current analytical methods, global marine VOCs measurements, their effects on SOA, and future needs for understanding the role of marine VOCs in the chemistry of the atmosphere.
Collapse
Affiliation(s)
- Zhujun Yu
- Department of Ocean Science and Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Blvd, Nanshan District, Shenzhen, Guangdong 518055, China
| | - Ying Li
- Department of Ocean Science and Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Blvd, Nanshan District, Shenzhen, Guangdong 518055, China; Center for Oceanic and Atmospheric Science at SUSTech (COAST), Southern University of Science and Technology, Shenzhen, China.
| |
Collapse
|
8
|
Shi W, Huo X, Tian Y, Lu X, Yang L, Zhou Q, Wang X, Yu Q. Development of membrane inlet photoionization ion trap mass spectrometer for trace VOCs analysis. Talanta 2021; 230:122352. [PMID: 33934800 DOI: 10.1016/j.talanta.2021.122352] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 03/10/2021] [Accepted: 03/17/2021] [Indexed: 12/01/2022]
Abstract
With the development of instrumental miniaturization, the portable mass spectrometer is becoming a new tool for on-site rapid analysis of environmental samples. Membrane inlet (MI) and photoionization (PI) are two commonly used sampling and ionization techniques, respectively, as they both exhibit detection selectivity for volatile organic compounds (VOCs). In this paper, a membrane inlet photoionization ion trap mass spectrometer was developed for the direct analysis of VOCs in gaseous samples. With the new structure and timing design, various operation modes were proposed and tested. In particular, the use of pulse carrier gas can integrate the appropriate pressure conditions required by each module, thus improving the efficiency of analyte transport, ionization, and mass analysis. The detection limit of sub-ppb was obtained, and the response time can be greatly reduced by increasing the sample flow rate. Furthermore, the capability of selective enrichment for organic analytes was also realized by using a special accumulation mode with a modified sequence, which is easy to operate because no additional devices are needed.
Collapse
Affiliation(s)
- Wenyan Shi
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen, 518055, China; State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China
| | - Xinming Huo
- Division of Life Science & Health, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Yuan Tian
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen, 518055, China
| | - Xinqiong Lu
- Shenzhen Chin Instrument Co., Ltd., Shenzhen, 518055, China.
| | - Lili Yang
- Measurement Technology and Instrumentation Key Lab of Hebei Province, Yanshan University, Qinhuangdao, Hebei, 066004, China
| | - Qian Zhou
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen, 518055, China
| | - Xiaohao Wang
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen, 518055, China; State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China
| | - Quan Yu
- Division of Advanced Manufacturing, Tsinghua Shenzhen International Graduate School, Shenzhen, 518055, China.
| |
Collapse
|
9
|
Analysis of volatile emissions from grape berries infected with Aspergillus carbonarius using hyphenated and portable mass spectrometry. Sci Rep 2020; 10:21179. [PMID: 33273624 PMCID: PMC7713432 DOI: 10.1038/s41598-020-78332-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 11/17/2020] [Indexed: 11/08/2022] Open
Abstract
Mycotoxins represent a serious risk for human and animal health. Οchratoxin A (OTA) is a carcinogenic mycotoxin produced by A. carbonarius that constitutes a severe problem for viticulture. In this study, we investigate the development of novel detection and on-line monitoring approaches for the detection of OTA in the field (i.e. out of the chemical laboratory) using advanced molecular sensing. Both stand-alone and hyphenated mass spectrometry (MS) based systems (e.g. Time-of-Flight ToF-MS and gas chromatography GC combined with MS) and compact portable membrane inlet MS (MIMS) have been employed for the first time to detect and monitor volatile emissions of grape berries infected by the fungus Aspergillus carbonarius. In vacuo (electron impact-EI) and ambient ionisation (electrospray ionisation-ESI) techniques were also examined. On-line measurements of the volatile emissions of grape berries, infected by various strains of A. carbonarius with different toxicity levels, were performed resulting in different olfactory chemical profiles with a common core of characteristic mass fragments, which could be eventually used for on-site detection and monitoring allowing consequent improvement in food security.
Collapse
|
10
|
Abstract
Volatile organic compounds (VOCs) are pervasive in the environment. Since the early 1980s, substantial work has examined the detection of these materials, as they can indicate environmental changes that can affect human health. VOCs and similar compounds present a very specific sensing problem in that they are not reactive and often nonpolar, so it is difficult to find materials that selectively bind or adsorb them. A number of techniques are applied to vapor sensing. High resolution molecular separation approaches such as gas chromatography and mass spectrometry are well-characterized and offer high sensitivity, but are difficult to implement in portable, real-time monitors, whereas approaches such as chemiresistors are promising, but still in development. Gravimetric approaches, in which the mass of an adsorbed vapor is directly measured, have several potential advantages over other techniques but have so far lagged behind other approaches in performance and market penetration. This review aims to offer a comprehensive background on gravimetric sensing including underlying resonators and sensitizers, as well as a picture of applications and commercialization in the field.
Collapse
Affiliation(s)
- Christine K. McGinn
- Department of Electrical Engineering, Columbia University, New York, New York 10027-6902, United States
| | - Zachary A. Lamport
- Department of Electrical Engineering, Columbia University, New York, New York 10027-6902, United States
| | - Ioannis Kymissis
- Department of Electrical Engineering, Columbia University, New York, New York 10027-6902, United States
| |
Collapse
|
11
|
Development of Open-Tubular-Type Micro Gas Chromatography Column with Bump Structures. SENSORS 2019; 19:s19173706. [PMID: 31455012 PMCID: PMC6749250 DOI: 10.3390/s19173706] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 08/14/2019] [Accepted: 08/23/2019] [Indexed: 12/18/2022]
Abstract
Gas chromatography (GC) is the chemical analysis technique most widely used to separate and identify gas components, and it has been extensively applied in various gas analysis fields such as non-invasive medical diagnoses, indoor air quality monitoring, and outdoor environmental monitoring. Micro-electro-mechanical systems (MEMS)-based GC columns are essential for miniaturizing an integrated gas analysis system (Micro GC system). This study reports an open-tubular-type micro GC (μ-GC) column with internal bump structures (bump structure μ-GC column) that substantially increase the interaction between the gas mixture and a stationary phase. The developed bump structure μ-GC column, which was fabricated on a 2 cm × 2 cm μ-GC chip and coated with a non-polar stationary phase, is 1.5 m-long, 150 μm-wide, and 400 μm-deep. It has an internal microfluidic channel in which the bumps, which are 150 μm diameter half-circles, are alternatingly disposed to face each other on the surface of the microchannel. The fabricated bump structure μ-GC column yielded a height-equivalent-to-a-theoretical-plate (HETP) of 0.009 cm (11,110 plates/m) at an optimal carrier gas velocity of 17 cm/s. The mechanically robust bump structure μ-GC column proposed in this study achieved higher separation efficiency than a commercially available GC column and a typical μ-GC column with internal post structures classified as a semi-packed-type column. The experimental results demonstrate that the developed bump structure μ-GC column can separate a gas mixture completely, with excellent separation resolution for formaldehyde, benzene, toluene, ethylbenzene, and xylene mixture, under programmed operating temperatures.
Collapse
|
12
|
Comparison of Membrane Inlet and Capillary Introduction Miniature Mass Spectrometry for Liquid Analysis. Polymers (Basel) 2019; 11:polym11030567. [PMID: 30960551 PMCID: PMC6473344 DOI: 10.3390/polym11030567] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Revised: 03/22/2019] [Accepted: 03/25/2019] [Indexed: 01/17/2023] Open
Abstract
Membrane inlet mass spectrometry (MIMS) is commonly used for detecting the components in liquid samples. When a liquid sample flows through a membrane, certain analytes will permeate into the vacuum chamber of a mass spectrometer from the solution. The properties of the membrane directly determine the substances that can be detected by MIMS. A capillary introduction (CI) method we previously proposed can also be used to analyze gas and volatile organic compounds (VOCs) dissolved in liquids. When CI analysis is carried out, the sample is drawn into the mass spectrometer with no species discrimination. The performance of these two injection methods was compared in this study, and similar response time and limit of detection (LOD) can be acquired. Specifically, MIMS can provide better detection sensitivity for most inorganic gases and volatile organic compounds. In contrast, capillary introduction shows wider compatibility on analyte types and quantitative range, and it requires less sample consumption. As the two injection methods have comparable characteristics and can be coupled with a miniature mass spectrometer, factors such as cost, pollution, device size, and sample consumption should be comprehensively considered when choosing a satisfactory injection method in practical applications.
Collapse
|
13
|
The use of Nafion membranes to measure 2H/1H and 18O/16O isotopic ratios in water. J Memb Sci 2019. [DOI: 10.1016/j.memsci.2018.11.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
14
|
Li X, Zhang Y, Ge S, Qian J, Miao W. Portable linear ion trap mass spectrometer with compact multistage vacuum system and continuous atmospheric pressure interface. Analyst 2019; 144:5127-5135. [PMID: 31338496 DOI: 10.1039/c9an01047e] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
A portable linear ion trap mass spectrometer featuring a compact three-stage vacuum system, a continuous atmospheric pressure interface (CAPI), and a miniature ion funnel was developed and characterized. The dimensions and weight of the instrument were 38 × 26 × 23 cm3 and ∼20 kg, respectively. The combination of a three-stage vacuum system and CAPI reduced the pressure smoothly from atmospheric to ∼5 × 10-4 Torr, ensuring that the miniature ion funnel, quadrupole ion guide, and linear ion trap operated in a suitable and stable vacuum environment. The analytical performance of the instrument was evaluated with a nano-electron spray ionization source and a reserpine sample solution. A satisfactory mass resolution up to 4060 (m/Δm, FWHM) was achieved at m/z 609 when the mass scan rate was 495 Da s-1. Unit mass resolution was achieved at a mass scan rate of 6000 Da s-1. In addition, a limit of detection of 5 ng mL-1 was achieved and tandem mass spectrometry (MS3) was successfully performed with the instrument. Furthermore, the measurements showed high repeatability and stability (RSD < 6%). This portable mass spectrometer shows great potential for practical applications in on-site analyses, such as those required for food safety, drug analysis, environmental protection, forensic investigations, and homeland security.
Collapse
Affiliation(s)
- Xiaoxu Li
- School of Mechanical and Electrical Engineering, Soochow University, Suzhou, 215021, China.
| | | | | | | | | |
Collapse
|
15
|
Shi W, Lu X, Zhang J, Yu Q, Wang X. Pulsed capillary introduction applied to a miniature mass spectrometer for efficient liquid analysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2018; 32:2159-2165. [PMID: 30252995 DOI: 10.1002/rcm.8293] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Revised: 08/13/2018] [Accepted: 09/21/2018] [Indexed: 06/08/2023]
Abstract
RATIONALE Capillary sampling of liquids for direct mass spectrometry (MS) analysis is introduced. The low transfer rate of the solution in the capillary will affect the analytical sensitivity and the response time; hence a pulsed capillary introduction (PCI) method was proposed and characterized. METHODS The experiments were carried out using a miniature quadrupole mass spectrometer, and liquid can be spontaneously drawn into the vacuum chamber for subsequent ionization and detection. A simple up-and-down motor platform was used to control the brief contact of the capillary inlet with the liquid sample and implement pulsed injection. The pulsed sampling parameters were optimized based on the characterization and dynamic study of liquid transfer in capillaries. RESULTS Compared with continuous capillary introduction (CCI), PCI can reduce the response time of MS analysis from more than half a minute to a few seconds. In addition, it provides better detection sensitivity as the ion signals of all solution components are enhanced and the acquired limit of detection (LOD) of toluene is about eight times lower than CCI analysis. For each analysis, the consumed sample volume is only a few nanoliters and the absolute consumption of the analyte can reach the femtogram level. CONCLUSIONS The proposed PCI method is proved to be successful in improving the sampling efficiency when performing direct liquid analysis without increasing the vacuum load. A miniature MS instrument with a proper capillary inlet can possess flexible operation modes to meet different application demands.
Collapse
Affiliation(s)
- Wenyan Shi
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China
| | - Xinqiong Lu
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China
- Guangdong Province Engineering Research Center for Urban Water Recycling and Environmental Safety, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China
| | - Jianchao Zhang
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China
| | - Quan Yu
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China
| | - Xiaohao Wang
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China
| |
Collapse
|
16
|
Giannoukos S, Agapiou A, Brkić B, Taylor S. Volatolomics: A broad area of experimentation. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1105:136-147. [PMID: 30584978 DOI: 10.1016/j.jchromb.2018.12.015] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2018] [Revised: 11/19/2018] [Accepted: 12/13/2018] [Indexed: 01/06/2023]
Abstract
Chemical analysis (detection and monitoring) of compounds associated with the metabolic activities of an organism is at the cutting edge of science. Volatile metabolomics (volatolomics) are applied in a broad range of applications including: biomedical research (e.g. disease diagnostic tools, personalized healthcare and nutrition, etc.), toxicological analysis (e.g. exposure tool to environmental pollutants, toxic and hazardous chemical environments, industrial accidents, etc.), molecular communications, forensics, safety and security (e.g. search and rescue operations). In the present review paper, an overview of recent advances and applications of volatolomics will be given. The main focus will be on volatile organic compounds (VOCs) originating from biological secretions of various organisms (e.g. microorganisms, insects, plants, humans) and resulting fusion of chemical information. Bench-top and portable or field-deployable technologies-systems will also be presented and discussed.
Collapse
Affiliation(s)
- S Giannoukos
- Laboratory of Atmospheric Chemistry, Paul Scherrer Institute (PSI), 5232 Villigen, Switzerland; University of Liverpool, Department of Electrical Engineering and Electronics, Liverpool L69 3GJ, UK
| | - A Agapiou
- University of Cyprus, Department of Chemistry, P.O. Box 20357, 1678 Nicosia, Cyprus.
| | - B Brkić
- BioSense Institute, University of Novi Sad, Dr Zorana Đinđića 1, 21 101 Novi Sad, Serbia
| | - S Taylor
- University of Liverpool, Department of Electrical Engineering and Electronics, Liverpool L69 3GJ, UK; Q Technologies Ltd, 100 Childwall Road, Liverpool L15 6UX, UK.
| |
Collapse
|
17
|
Gold nanoparticles-enhanced ion-transmission mass spectrometry for highly sensitive detection of chemical warfare agent simulants. Talanta 2018; 190:403-409. [PMID: 30172526 DOI: 10.1016/j.talanta.2018.08.021] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Revised: 07/31/2018] [Accepted: 08/05/2018] [Indexed: 01/01/2023]
Abstract
Gold nanoparticles (AuNPs)-embedded paper was coupled with ion-transmission mass spectrometry (MS) to enable the highly sensitive detection of chemical warfare agent (CWA) simulants in solutions. With the assistance of a low-temperature plasma (LTP) probe, we found that AuNPs were capable to enhance the ionization efficiencies of target analytes, with MS signal intensities surprisingly undergone an 800-fold increase under optimized conditions. The interaction between AuNPs and the radiofrequency electromagnetic field was believed to promote the desorption/ionization process, resulting in the unusual signal enhancement phenomenon. Based on this finding, we established a method for the rapid analysis of two simulants of nerve agents, dimethyl methylphosphonate (DMMP) and diisopropyl methylphosphonate (DIMP), with a dynamic range from 0.5 ng/mL to 100 ng/mL and detection limits of 0.1 ng/mL and 0.3 ng/mL, respectively. As sample pretreatments have been eliminated, the developed strategy is particularly promising for the on-site detection of CWAs considering its simple and rapid analytical workflow.
Collapse
|
18
|
de Araujo WR, Cardoso TM, da Rocha RG, Santana MH, Muñoz RA, Richter EM, Paixão TR, Coltro WK. Portable analytical platforms for forensic chemistry: A review. Anal Chim Acta 2018; 1034:1-21. [DOI: 10.1016/j.aca.2018.06.014] [Citation(s) in RCA: 123] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2018] [Revised: 05/18/2018] [Accepted: 06/07/2018] [Indexed: 01/28/2023]
|
19
|
Gordon D, Nawała J, Szala M, Dziedzic D, Dawidziuk B, Popiel S. Development of analytical methods used for the study of 2,4,6-trinitrotoluene degradation kinetics in simulated sediment samples from the Baltic Sea. MARINE POLLUTION BULLETIN 2018; 135:397-410. [PMID: 30301051 DOI: 10.1016/j.marpolbul.2018.07.039] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Revised: 07/13/2018] [Accepted: 07/15/2018] [Indexed: 06/08/2023]
Abstract
Large amounts of ammunition containing 2,4,6-trinitrotoluene (TNT) and other substances were dumped in the Baltic Sea after WWII. Considering progressive corrosion processes, studying the transformation of TNT occurring in the environment constitutes an important aspect of a possible associated risk. This study focused on the transformations of TNT in simulated conditions of the Baltic Sea bottom sediment. Methods of analysis of TNT and selected products of its transformations were developed for that purpose. The developed methods allowed for the determination of selected compounds below 1 ng/g. Systematic monitoring of TNT transformations in the environment of the bottom sediment was performed. This allowed for the determination of the kinetics of TNT degradation and identification of degradation reaction products. Based on the obtained results, the TNT decay half-time in conditions present in the Baltic Sea was estimated to be 16.7 years for the abiotic environment and 5.6 for the biotic environment.
Collapse
Affiliation(s)
- Diana Gordon
- Military University of Technology, Institute of Chemistry, Gen. W. Urbanowicza 2, 00-908 Warsaw, Poland
| | - Jakub Nawała
- Military University of Technology, Institute of Chemistry, Gen. W. Urbanowicza 2, 00-908 Warsaw, Poland.
| | - Mateusz Szala
- Military University of Technology, Institute of Chemistry, Gen. W. Urbanowicza 2, 00-908 Warsaw, Poland
| | - Daniel Dziedzic
- Military University of Technology, Institute of Chemistry, Gen. W. Urbanowicza 2, 00-908 Warsaw, Poland
| | - Barbara Dawidziuk
- Military University of Technology, Institute of Chemistry, Gen. W. Urbanowicza 2, 00-908 Warsaw, Poland
| | - Stanisław Popiel
- Military University of Technology, Institute of Chemistry, Gen. W. Urbanowicza 2, 00-908 Warsaw, Poland
| |
Collapse
|
20
|
Wallace MAG, Pleil JD. Evolution of clinical and environmental health applications of exhaled breath research: Review of methods and instrumentation for gas-phase, condensate, and aerosols. Anal Chim Acta 2018; 1024:18-38. [PMID: 29776545 PMCID: PMC6082128 DOI: 10.1016/j.aca.2018.01.069] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2017] [Revised: 01/29/2018] [Accepted: 01/31/2018] [Indexed: 12/20/2022]
Abstract
Human breath, along with urine and blood, has long been one of the three major biological media for assessing human health and environmental exposure. In fact, the detection of odor on human breath, as described by Hippocrates in 400 BC, is considered the first analytical health assessment tool. Although less common in comparison to contemporary bio-fluids analyses, breath has become an attractive diagnostic medium as sampling is non-invasive, unlimited in timing and volume, and does not require clinical personnel. Exhaled breath, exhaled breath condensate (EBC), and exhaled breath aerosol (EBA) are different types of breath matrices used to assess human health and disease state. Over the past 20 years, breath research has made many advances in assessing health state, overcoming many of its initial challenges related to sampling and analysis. The wide variety of sampling techniques and collection devices that have been developed for these media are discussed herein. The different types of sensors and mass spectrometry instruments currently available for breath analysis are evaluated as well as emerging breath research topics, such as cytokines, security and airport surveillance, cellular respiration, and canine olfaction.
Collapse
Affiliation(s)
- M Ariel Geer Wallace
- U.S. Environmental Protection Agency, Office of Research and Development, National Exposure Research Laboratory, 109 T.W. Alexander Drive, Research Triangle Park, NC, 27711, USA.
| | - Joachim D Pleil
- U.S. Environmental Protection Agency, Office of Research and Development, National Exposure Research Laboratory, 109 T.W. Alexander Drive, Research Triangle Park, NC, 27711, USA.
| |
Collapse
|
21
|
Villar GV, Quinete N, Gardinali PR. Using Polydimethylsiloxane (PDMS) Pellets to Create an Absorption Model for the Determination of Equilibrium Concentrations of Dissolved Contaminants in the Aquatic Environment. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY 2018; 101:349-357. [PMID: 30084017 DOI: 10.1007/s00128-018-2410-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Accepted: 07/30/2018] [Indexed: 06/08/2023]
Abstract
Polydimethylsiloxane (PDMS) is a polymer material with high absorptive properties increasingly used as a passive environmental sampler for persistent organic compounds. However, the partitioning behavior of hydrophobic chemicals to PDMS remains largely unknown. Organochlorines (OCs) and polycyclic aromatic hydrocarbons (PAHs) are ubiquitous environmental pollutants of great concern due to their persistence and potential toxic effects on humans and animals. In this study, the affinity of 20 OCs and 25 PAHs for commercially available PDMS pellets was determined to assess their effectiveness as passive samplers. Experiments were conducted to estimate the absorption rates (k) and equilibrium concentrations, demonstrating that 16 OCs and 21 PAHs were efficiently absorbed by PDMS, while others remained dissolved in water. A model has been proposed to predict dissolved concentrations in water based on the Kow of the compound, suggesting that PDMS is a suitable passive sampler for these compounds.
Collapse
Affiliation(s)
- Gilberto Vasconcelos Villar
- Department of Chemistry and Biochemistry, Florida International University, University Park, Miami, FL, 33199, USA
| | - Natalia Quinete
- Southeast Environmental Research Center (SERC), Florida International University, University Park, Miami, FL, 33199, USA.
- Florida International University, 3000 NE 151st Street, FIU Biscayne Bay Campus, MSB 232, North Miami, FL, 33181, USA.
| | - Piero R Gardinali
- Department of Chemistry and Biochemistry, Florida International University, University Park, Miami, FL, 33199, USA
- Southeast Environmental Research Center (SERC), Florida International University, University Park, Miami, FL, 33199, USA
| |
Collapse
|
22
|
Brkić B, France N, Giannoukos S, Taylor S. An optimised quadrupole mass spectrometer with a dual filter analyser for in-field chemical sniffing of volatile organic compounds. Analyst 2018; 143:3722-3728. [PMID: 29987272 DOI: 10.1039/c8an00862k] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We report a novel portable 17 kg system based on a quadrupole mass spectrometer (QMS) with an electronic power consumption of 24 W. The system can be used for the in-field identification of gases and volatile/semivolatile organic compounds (VOCs/SVOCs). The mass analyser is a custom-made quadrupole mass filter with a Brubaker pre-filter that gives a mass range of m/z 1-500. It is an upgrade of the previous m/z 1-200 range triple filter analyser system. Analyser design was optimized using 3D numerical simulations as a performance trade-off between single and triple filter designs while maintaining high sensitivity and ease of integration. This also required enhanced design of the electronic control unit (ECU) compared to the previous triple filter ECU designs with lower power consumption, size, weight and cost of the overall system. Another major ECU improvement includes high stability of DC voltage control and ultra-low RF drift, which is important for in-field applications that require stable mass peaks for reliable quantitative analysis and continuous monitoring. Experimental results are presented for the perfluorotributylamine (PFTBA) calibrant and acetone to assess the functionality of the instrument. Performance comparison between the dual and triple filter quadrupole analysers has also been done. Mass spectra are given for methyl benzoate (cocaine simulant), piperidine (phencyclidine simulant), cyclohexanone (C4 simulant) and 2-nitrotoluene (TNT simulant) to assess potential capability for the identification of threat compounds. All spectral results show good correlation with the NIST library mass spectra with unit resolution obtained for spectral peaks within a m/z 1-400 mass range.
Collapse
Affiliation(s)
- Boris Brkić
- BioSense Institute, University of Novi Sad, Dr Zorana Đinđića 1, 21 000 Novi Sad, Serbia.
| | | | | | | |
Collapse
|
23
|
Casas-Ferreira AM, Nogal-Sánchez MD, Pérez-Pavón JL, Moreno-Cordero B. Non-separative mass spectrometry methods for non-invasive medical diagnostics based on volatile organic compounds: A review. Anal Chim Acta 2018; 1045:10-22. [PMID: 30454564 DOI: 10.1016/j.aca.2018.07.005] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Revised: 05/16/2018] [Accepted: 07/02/2018] [Indexed: 12/18/2022]
Abstract
In this review, an assessment of non-separative methods based on mass spectrometry used to analyse volatile organic compounds in the field of bioanalysis is performed. The use of non-separative methods based on mass spectrometry has been established as an attractive option for analysing compounds. These instrumental configurations are suitable for biomedical applications because of their versatility, rapid output of results, and the wide range of volatile organic compounds that can be determined. Here, techniques such as headspace sampling coupled to mass spectrometry, membrane introduction mass spectrometry, selected ion flow tube mass spectrometry, proton transfer reaction mass spectrometry, secondary electrospray ionization mass spectrometry and ion mobility mass spectrometry, are evaluated. Samples involving non-invasive methods of collection, such as urine, saliva, breath and sweat, are mainly considered. To the best of our knowledge, a comprehensive review of all the non-separative instrumental configurations applied to the analysis of gaseous samples from all matrices non-invasively collected has not yet been carried out. The assessment of non-separative techniques for the analysis of these type of samples can be considered a key issue for future clinical applications, as they allow real-time sample analysis, without patient suffering. Any contribution to the early diagnosis of disease can be considered a priority for the scientific community. Therefore, the identification and determination of volatile organic compounds related to particular diseases has become an important field or research.
Collapse
Affiliation(s)
- Ana María Casas-Ferreira
- Departamento de Química Analítica, Nutrición y Bromatología Facultad de Ciencias Químicas, Universidad de Salamanca, 37008 Salamanca, Spain
| | - Miguel Del Nogal-Sánchez
- Departamento de Química Analítica, Nutrición y Bromatología Facultad de Ciencias Químicas, Universidad de Salamanca, 37008 Salamanca, Spain.
| | - José Luis Pérez-Pavón
- Departamento de Química Analítica, Nutrición y Bromatología Facultad de Ciencias Químicas, Universidad de Salamanca, 37008 Salamanca, Spain
| | - Bernardo Moreno-Cordero
- Departamento de Química Analítica, Nutrición y Bromatología Facultad de Ciencias Químicas, Universidad de Salamanca, 37008 Salamanca, Spain
| |
Collapse
|
24
|
Giannoukos S, McGuiness DT, Marshall A, Smith J, Taylor S. A Chemical Alphabet for Macromolecular Communications. Anal Chem 2018; 90:7739-7746. [DOI: 10.1021/acs.analchem.8b01716] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Stamatios Giannoukos
- Department of Electrical Engineering and Electronics, University of Liverpool, Brownlow Hill, Liverpool, L69 3GJ, United Kingdom
| | - Daniel Tunç McGuiness
- Department of Electrical Engineering and Electronics, University of Liverpool, Brownlow Hill, Liverpool, L69 3GJ, United Kingdom
| | - Alan Marshall
- Department of Electrical Engineering and Electronics, University of Liverpool, Brownlow Hill, Liverpool, L69 3GJ, United Kingdom
| | - Jeremy Smith
- Department of Electrical Engineering and Electronics, University of Liverpool, Brownlow Hill, Liverpool, L69 3GJ, United Kingdom
| | - Stephen Taylor
- Department of Electrical Engineering and Electronics, University of Liverpool, Brownlow Hill, Liverpool, L69 3GJ, United Kingdom
| |
Collapse
|
25
|
Giannoukos S, Agapiou A, Taylor S. Advances in chemical sensing technologies for VOCs in breath for security/threat assessment, illicit drug detection, and human trafficking activity. J Breath Res 2018; 12:027106. [DOI: 10.1088/1752-7163/aa95dd] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
26
|
Zhou MD, Akbar M, Myrick AJ, Xia Y, Khan WJ, Gao X, Baker TC, Zheng SY. Chopper-modulated gas chromatography electroantennography enabled using high-temperature MEMS flow control device. MICROSYSTEMS & NANOENGINEERING 2017; 3:17062. [PMID: 31057886 PMCID: PMC6444993 DOI: 10.1038/micronano.2017.62] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Revised: 07/07/2017] [Accepted: 07/26/2017] [Indexed: 06/09/2023]
Abstract
We report the design, fabrication and characterization of a microelectromechanical systems (MEMS) flow control device for gas chromatography (GC) with the capability of sustaining high-temperature environments. We further demonstrate the use of this new device in a novel MEMS chopper-modulated gas chromatography-electroantennography (MEMS-GC-EAG) system to identify specific volatile organic compounds (VOCs) at extremely low concentrations. The device integrates four pneumatically actuated microvalves constructed via thermocompression bonding of the polyimide membrane between two glass substrates with microstructures. The overall size of the device is 32 mm×32 mm, and it is packaged in a 50 mm×50 mm aluminum housing that provides access to the fluidic connections and allows thermal control. The characterization reveals that each microvalve in the flow control chip provides an ON to OFF ratio as high as 1000:1. The device can operate reliably for more than 1 million switching cycles at a working temperature of 300 °C. Using the MEMS-GC-EAG system, we demonstrate the successful detection of cis-11-hexadecenal with a concentration as low as 1 pg at a demodulation frequency of 2 Hz by using an antenna harvested from the male Helicoverpa Virescens moth. In addition, 1 μg of a green leafy volatile (GLV) is barely detected using the conventional GC-EAG, while MEMS-GC-EAG can readily detect the same amount of GLV, with an improvement in the signal-to-noise ratio (SNR) of ~22 times. We expect that the flow control device presented in this report will allow researchers to explore new applications and make new discoveries in entomology and other fields that require high-temperature flow control at the microscale.
Collapse
Affiliation(s)
- Ming-Da Zhou
- Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
- Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
| | - Muhammad Akbar
- Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
- Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
| | - Andrew J. Myrick
- Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
- Department of Entomology, The Pennsylvania State University, University Park, PA 16802, USA
| | - Yiqiu Xia
- Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
- Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
| | - Waleed J. Khan
- Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
- Department of Electrical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Xiang Gao
- Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Thomas C. Baker
- Department of Entomology, The Pennsylvania State University, University Park, PA 16802, USA
| | - Si-Yang Zheng
- Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
- Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
- Department of Electrical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| |
Collapse
|
27
|
Yu Q, Zhang Q, Lu X, Qian X, Ni K, Wang X. Developing a Vacuum Electrospray Source To Implement Efficient Atmospheric Sampling for Miniature Ion Trap Mass Spectrometer. Anal Chem 2017; 89:12938-12944. [PMID: 29091419 DOI: 10.1021/acs.analchem.7b03797] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The performance of a miniature mass spectrometer in atmospheric analysis is closely related to the design of its sampling system. In this study, a simplified vacuum electrospray ionization (VESI) source was developed based on a combination of several techniques, including the discontinuous atmospheric pressure interface, direct capillary sampling, and pneumatic-assisted electrospray. Pulsed air was used as a vital factor to facilitate the operation of electrospray ionization in the vacuum chamber. This VESI device can be used as an efficient atmospheric sampling interface when coupled with a miniature rectilinear ion trap (RIT) mass spectrometer. The developed VESI-RIT instrument enables regular ESI analysis of liquid, and its qualitative and quantitative capabilities have been characterized by using various solution samples. A limit of detection of 8 ppb could be attained for arginine in a methanol solution. In addition, extractive electrospray ionization of organic compounds can be implemented by using the same VESI device, as long as the gas analytes are injected with the pulsed auxiliary air. This methodology can extend the use of the proposed VESI technique to rapid and online analysis of gaseous and volatile samples.
Collapse
Affiliation(s)
- Quan Yu
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University , Shenzhen 518055, China
| | - Qian Zhang
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University , Shenzhen 518055, China
| | - Xinqiong Lu
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University , Shenzhen 518055, China
| | - Xiang Qian
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University , Shenzhen 518055, China
| | - Kai Ni
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University , Shenzhen 518055, China
| | - Xiaohao Wang
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University , Shenzhen 518055, China.,State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University , Beijing 100084, China
| |
Collapse
|
28
|
Giannoukos S, Marshall A, Taylor S, Smith J. Molecular Communication over Gas Stream Channels using Portable Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:2371-2383. [PMID: 28733965 DOI: 10.1007/s13361-017-1752-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2017] [Revised: 06/30/2017] [Accepted: 06/30/2017] [Indexed: 06/07/2023]
Abstract
The synthetic generation/coding and transmission of olfactory information over a gas stream or an odor network is a new and unexplored field. Application areas vary from the entertainment or advertisement industry to security and telemedicine. However, current technological limitations frustrate the accurate reproduction of decoded and transmitted olfactory data. This study describes the development, testing, and characterization of a novel odor emitter (OE) that is used to investigate the generation-encoding of gaseous standards with odorous characteristics with a regulatable way, for scent transmission purposes. The calibration and the responses of a developed OE were examined using a portable quadrupole mass spectrometer (MS). Experiments were undertaken for a range of volatile organic compounds (VOCs) at different temperatures and flow rates. Individual compounds and mixtures were tested to investigate periodic and dynamic transmission characteristics within two different size tubular containers for distances up to 3 m. Olfactory information transmission is demonstrated using MS as the main molecular sensor for odor detection and monitoring and for the first time spatial encryption of olfactory information is shown. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Stamatios Giannoukos
- Department of Electrical Engineering and Electronics, University of Liverpool, Brownlow Hill, Liverpool, L69 3GJ, UK
| | - Alan Marshall
- Department of Electrical Engineering and Electronics, University of Liverpool, Brownlow Hill, Liverpool, L69 3GJ, UK
| | - Stephen Taylor
- Department of Electrical Engineering and Electronics, University of Liverpool, Brownlow Hill, Liverpool, L69 3GJ, UK.
| | - Jeremy Smith
- Department of Electrical Engineering and Electronics, University of Liverpool, Brownlow Hill, Liverpool, L69 3GJ, UK
| |
Collapse
|
29
|
Dhummakupt ES, Mach PM, Carmany D, Demond PS, Moran TS, Connell T, Wylie HS, Manicke NE, Nilles JM, Glaros T. Direct Analysis of Aerosolized Chemical Warfare Simulants Captured on a Modified Glass-Based Substrate by "Paper-Spray" Ionization. Anal Chem 2017; 89:10866-10872. [PMID: 28898050 DOI: 10.1021/acs.analchem.7b02530] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Paper spray ionization mass spectrometry offers a rapid alternative platform requiring no sample preparation. Aerosolized chemical warfare agent (CWA) simulants trimethyl phosphate, dimethyl methylphosphonate, and diisopropyl methylphosphonate were captured by passing air through a glass fiber filter disk within a disposable paper spray cartridge. CWA simulants were aerosolized at varying concentrations using an in-house built aerosol chamber. A custom 3D-printed holder was designed and built to facilitate the aerosol capture onto the paper spray cartridges. The air flow through each of the collection devices was maintained equally to ensure the same volume of air sampled across methods. Each approach yielded linear calibration curves with R2 values between 0.98-0.99 for each compound and similar limits of detection in terms of disbursed aerosol concentration. While the glass fiber filter disk has a higher capture efficiency (≈40%), the paper spray method produces analogous results even with a lower capture efficiency (≈1%). Improvements were made to include glass fiber filters as the substrate within the paper spray cartridge consumable. Glass fiber filters were then treated with ammonium sulfate to decrease chemical interaction with the simulants. This allowed for improved direct aerosol capture efficiency (>40%). Ultimately, the limits of detection were reduced to levels comparable to current worker population limits of 1 × 10-6 mg/m3.
Collapse
Affiliation(s)
- Elizabeth S Dhummakupt
- Research and Technology Directorate, US Army Edgewood Chemical Biological Center (ECBC) , Aberdeen Proving Ground, Maryland 21010, United States
| | - Phillip M Mach
- Excet, Inc. , 6225 Brandon Ave, Suite 360, Springfield, Virginia 22150, United States
| | - Daniel Carmany
- Excet, Inc. , 6225 Brandon Ave, Suite 360, Springfield, Virginia 22150, United States
| | - Paul S Demond
- Excet, Inc. , 6225 Brandon Ave, Suite 360, Springfield, Virginia 22150, United States
| | - Theodore S Moran
- Research and Technology Directorate, US Army Edgewood Chemical Biological Center (ECBC) , Aberdeen Proving Ground, Maryland 21010, United States
| | - Theresa Connell
- Excet, Inc. , 6225 Brandon Ave, Suite 360, Springfield, Virginia 22150, United States
| | - Harold S Wylie
- TriMech Services, LLC , 4461 Cox Rd # 302, Glen Allen, Virginia 23060, United States
| | - Nicholas E Manicke
- Department of Chemistry and Chemical Biology, Indiana University-Purdue University Indianapolis , Indianapolis, Indiana 46202, United States
| | - J Michael Nilles
- Excet, Inc. , 6225 Brandon Ave, Suite 360, Springfield, Virginia 22150, United States
| | - Trevor Glaros
- Research and Technology Directorate, US Army Edgewood Chemical Biological Center (ECBC) , Aberdeen Proving Ground, Maryland 21010, United States
| |
Collapse
|
30
|
Snyder DT, Cooks RG. Single Analyzer Precursor Ion Scans in a Linear Quadrupole Ion Trap Using Orthogonal Double Resonance Excitation. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:1929-1938. [PMID: 28577288 DOI: 10.1007/s13361-017-1707-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Revised: 05/02/2017] [Accepted: 05/05/2017] [Indexed: 06/07/2023]
Abstract
Reported herein is a simple method of performing single analyzer precursor ion scans in a linear quadrupole ion trap using orthogonal double resonance excitation. A first supplementary AC signal applied to the y electrodes is scanned through ion secular frequencies in order to mass-selectively excite precursor ions while, simultaneously, a second fixed-frequency AC signal is applied orthogonally on the x electrodes in order to eject product ions of selected mass-to-charge ratios towards the detector. The two AC signals are applied orthogonally so as to preclude the possibility of (1) inadvertently ejecting precursor ions into the detector, which results in artifact peaks, and (2) prevent beat frequencies on the x electrodes from ejecting ions off-resonance. Precursor ion scans are implemented while using the inverse Mathieu q scan for easier mass calibration. The orthogonal double resonance experiment results in single ion trap precursor scans with far less intense artifact peaks than when both AC signals are applied to the same electrodes, paving the way for implementation of neutral loss scanning in single ion trap mass spectrometers. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Dalton T Snyder
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA
| | - R Graham Cooks
- Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA.
| |
Collapse
|
31
|
Lu X, Yu Q, Zhang Q, Ni K, Qian X, Tang F, Wang X. Direct Analysis of Organic Compounds in Liquid Using a Miniature Photoionization Ion Trap Mass Spectrometer with Pulsed Carrier-Gas Capillary Inlet. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:1702-1708. [PMID: 28432655 DOI: 10.1007/s13361-017-1683-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2016] [Revised: 04/06/2017] [Accepted: 04/07/2017] [Indexed: 06/07/2023]
Abstract
A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Xinqiong Lu
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China
- State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing, 100084, China
| | - Quan Yu
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China.
| | - Qian Zhang
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China
| | - Kai Ni
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China
| | - Xiang Qian
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China
| | - Fei Tang
- State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing, 100084, China
| | - Xiaohao Wang
- Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China.
- State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing, 100084, China.
| |
Collapse
|
32
|
Pulliam CJ, Bain RM, Osswald HL, Snyder DT, Fedick PW, Ayrton ST, Flick TG, Cooks RG. Simultaneous Online Monitoring of Multiple Reactions Using a Miniature Mass Spectrometer. Anal Chem 2017; 89:6969-6975. [PMID: 28520396 DOI: 10.1021/acs.analchem.7b00119] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Christopher J. Pulliam
- Department
of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
| | - Ryan M. Bain
- Department
of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
| | - Heather L. Osswald
- Department
of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
| | - Dalton T. Snyder
- Department
of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
| | - Patrick W. Fedick
- Department
of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
| | - Stephen T. Ayrton
- Department
of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
| | - Tawnya G. Flick
- Department
of Attribute Sciences, Amgen Inc., 1 Amgen Center Drive, Thousand Oaks, California 91320, United States
| | - R. Graham Cooks
- Department
of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, United States
- Center for Analytical Instrumentation Development, West Lafayette, Indiana 47907, United States
| |
Collapse
|
33
|
Giannoukos S, Brkić B, Taylor S, Marshall A, Verbeck GF. Chemical Sniffing Instrumentation for Security Applications. Chem Rev 2016; 116:8146-72. [PMID: 27388215 DOI: 10.1021/acs.chemrev.6b00065] [Citation(s) in RCA: 93] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Border control for homeland security faces major challenges worldwide due to chemical threats from national and/or international terrorism as well as organized crime. A wide range of technologies and systems with threat detection and monitoring capabilities has emerged to identify the chemical footprint associated with these illegal activities. This review paper investigates artificial sniffing technologies used as chemical sensors for point-of-use chemical analysis, especially during border security applications. This article presents an overview of (a) the existing available technologies reported in the scientific literature for threat screening, (b) commercially available, portable (hand-held and stand-off) chemical detection systems, and (c) their underlying functional and operational principles. Emphasis is given to technologies that have been developed for in-field security operations, but laboratory developed techniques are also summarized as emerging technologies. The chemical analytes of interest in this review are (a) volatile organic compounds (VOCs) associated with security applications (e.g., illegal, hazardous, and terrorist events), (b) chemical "signatures" associated with human presence, and
Collapse
Affiliation(s)
- Stamatios Giannoukos
- Department of Electrical Engineering and Electronics, University of Liverpool , Liverpool, L69 3GJ, U.K
| | - Boris Brkić
- Department of Electrical Engineering and Electronics, University of Liverpool , Liverpool, L69 3GJ, U.K.,Q-Technologies Ltd., 100 Childwall Road, Liverpool, L15 6UX, U.K
| | - Stephen Taylor
- Department of Electrical Engineering and Electronics, University of Liverpool , Liverpool, L69 3GJ, U.K.,Q-Technologies Ltd., 100 Childwall Road, Liverpool, L15 6UX, U.K
| | - Alan Marshall
- Department of Electrical Engineering and Electronics, University of Liverpool , Liverpool, L69 3GJ, U.K
| | - Guido F Verbeck
- Department of Chemistry, University of North Texas , Denton, Texas 76201, United States
| |
Collapse
|
34
|
Affiliation(s)
- Dalton T. Snyder
- Department of Chemistry and Center for Analytical Instrumentation
Development, Purdue University, W. Lafayette, IN 47907
| | - Christopher J. Pulliam
- Department of Chemistry and Center for Analytical Instrumentation
Development, Purdue University, W. Lafayette, IN 47907
| | - Zheng Ouyang
- Weldon School of Biomedical Engineering, Purdue University, W.
Lafayette, IN 47907
| | - R. Graham Cooks
- Department of Chemistry and Center for Analytical Instrumentation
Development, Purdue University, W. Lafayette, IN 47907
| |
Collapse
|
35
|
Brown KE, Greenfield MT, McGrane SD, Moore DS. Advances in explosives analysis--part I: animal, chemical, ion, and mechanical methods. Anal Bioanal Chem 2015; 408:35-47. [PMID: 26462922 DOI: 10.1007/s00216-015-9040-4] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2015] [Revised: 08/17/2015] [Accepted: 09/10/2015] [Indexed: 11/29/2022]
Abstract
The number and capability of explosives detection and analysis methods have increased substantially since the publication of the Analytical and Bioanalytical Chemistry special issue devoted to Explosives Analysis (Moore and Goodpaster, Anal Bioanal Chem 395(2):245-246, 2009). Here we review and critically evaluate the latest (the past five years) important advances in explosives detection, with details of the improvements over previous methods, and suggest possible avenues towards further advances in, e.g., stand-off distance, detection limit, selectivity, and penetration through camouflage or packaging. The review consists of two parts. This part, Part I, reviews methods based on animals, chemicals (including colorimetry, molecularly imprinted polymers, electrochemistry, and immunochemistry), ions (both ion-mobility spectrometry and mass spectrometry), and mechanical devices. Part II will review methods based on photons, from very energetic photons including X-rays and gamma rays down to the terahertz range, and neutrons.
Collapse
Affiliation(s)
- Kathryn E Brown
- Shock and Detonation Physics Group, Los Alamos National Laboratory, Los Alamos, NM, 87545, USA
| | - Margo T Greenfield
- Shock and Detonation Physics Group, Los Alamos National Laboratory, Los Alamos, NM, 87545, USA
| | - Shawn D McGrane
- Shock and Detonation Physics Group, Los Alamos National Laboratory, Los Alamos, NM, 87545, USA
| | - David S Moore
- Shock and Detonation Physics Group, Los Alamos National Laboratory, Los Alamos, NM, 87545, USA.
| |
Collapse
|