1
|
Venter AR. Protein analysis by desorption electrospray ionization mass spectrometry. MASS SPECTROMETRY REVIEWS 2024. [PMID: 39056172 DOI: 10.1002/mas.21900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 05/22/2024] [Accepted: 07/08/2024] [Indexed: 07/28/2024]
Abstract
This review presents progress made in the ambient analysis of proteins, in particular by desorption electrospray ionization-mass spectrometry (DESI-MS). Related ambient ionization techniques are discussed in comparison to DESI-MS only to illustrate the larger context of protein analysis by ambient ionization mass spectrometry. The review describes early and current approaches for the analysis of undigested proteins, native proteins, tryptic digests, and indirect protein determination through reporter molecules. Applications to mass spectrometry imaging for protein spatial distributions, the identification of posttranslational modifications, determination of binding stoichiometries, and enzymatic transformations are discussed. The analytical capabilities of other ambient ionization techniques such as LESA and nano-DESI currently exceed those of DESI-MS for in situ surface sampling of intact proteins from tissues. This review shows, however, that despite its many limitations, DESI-MS is making valuable contributions to protein analysis. The challenges in sensitivity, spatial resolution, and mass range are surmountable obstacles and further development and improvements to DESI-MS is justified.
Collapse
Affiliation(s)
- Andre R Venter
- Department of Chemistry, Western Michigan University, Kalamazoo, Michigan, USA
| |
Collapse
|
2
|
Williams JD, Pu F, Sawicki JW, Elsen NL. Ultra-high-throughput mass spectrometry in drug discovery: fundamentals and recent advances. Expert Opin Drug Discov 2024; 19:291-301. [PMID: 38111363 DOI: 10.1080/17460441.2023.2293153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Accepted: 12/06/2023] [Indexed: 12/20/2023]
Abstract
INTRODUCTION Ultra-high-throughput mass spectrometry, uHT-MS, is a technology that utilizes ionization and sample delivery technologies optimized to enable sampling from well plates at > 1 sample per second. These technologies do not need a chromatographic separation step and can be utilized in a wide variety of assays to detect a broad range of analytes including small molecules, lipids, and proteins. AREAS COVERED This manuscript provides a brief historical review of high-throughput mass spectrometry and the recently developed technologies that have enabled uHT-MS. The report also provides examples and references on how uHT-MS has been used in biochemical and chemical assays, nuisance compound profiling, protein analysis and high throughput experimentation for chemical synthesis. EXPERT OPINION The fast analysis time provided by uHT-MS is transforming how biochemical and chemical assays are performed in drug discovery. The potential to associate phenotypic responses produced by 1000's of compound treatments with changes in endogenous metabolite and lipid signals is becoming feasible. With the augmentation of simple, fast, high-throughput sample preparation, the scope of uHT-MS usage will increase. However, it likely will not supplant LC-MS for analyses that require low detection limits from complex matrices or characterization of complex biotherapeutics such as antibody-drug conjugates.
Collapse
Affiliation(s)
| | - Fan Pu
- Abbvie Discovery Research, North Chicago, IL, USA
| | | | | |
Collapse
|
3
|
Javanshad R, Panth R, Venter AR. Effects of Amino Acid Additives on Protein Stability during Electrothermal Supercharging in ESI-MS. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:151-157. [PMID: 38078777 DOI: 10.1021/jasms.3c00377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2024]
Abstract
The surprising formation of highly charged protein ions from aqueous ammonium bicarbonate solution is a fascinating phenomenon referred to as electrothermal supercharging (ETS). Although the precise mechanism involved is not clearly understood, previous studies predominantly suggest that ETS is due to native protein destabilization in the presence of bicarbonate anion inside the electrospray ionization droplets under high temperatures and spray voltages. To evaluate existing hypotheses surrounding the underlying mechanism of ETS, the effects of several additives on protein charging under ETS conditions were investigated. The changes in the protein charge state distributions were compared by measuring the ratios between the intensities of highest intensity charge states of native and unfolded protein envelopes and shifts in the lowest and highest observed charge states. This study demonstrated that source temperature plays a more important role in ETS compared to spray voltage, especially when using a nebulized microelectrospray ionization source. Moreover, the effect of amino acids on ETS were generally in good agreement with the extensive literature available on the stabilization or destabilization of proteins by these additives in bulk solution. Among the natural amino acids, protein supercharging was significantly reduced by proline and glycine; however, imidazole provided the highest degree of noncovalent complex stabilization against ETS, outperforming the amino acids. Overall, our study shows that the simple addition of stabilizing reagents such as proline and imidazole can reduce the extent of apparent protein unfolding and supercharging in ammonium bicarbonate solution and provide evidence against the roles of charge depletion and thermal unfolding during ETS.
Collapse
Affiliation(s)
- Roshan Javanshad
- Department of Chemistry, Western Michigan University, Kalamazoo, Michigan 49008-5413, United States
| | - Rajendra Panth
- Department of Chemistry, Western Michigan University, Kalamazoo, Michigan 49008-5413, United States
| | - Andre R Venter
- Department of Chemistry, Western Michigan University, Kalamazoo, Michigan 49008-5413, United States
| |
Collapse
|
4
|
Surface-sampling mass spectrometry to study proteins and protein complexes. Essays Biochem 2023; 67:229-241. [PMID: 36748325 PMCID: PMC10070487 DOI: 10.1042/ebc20220191] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 01/03/2023] [Accepted: 01/05/2023] [Indexed: 02/08/2023]
Abstract
This review aims to summarise the current capabilities of surface mass spectrometry (MS) approaches that offer intact protein analysis, and that of non-covalent complexes. Protein analysis is largely achieved via matrix-assisted laser desorption/ionisation (MALDI), which is in itself a surface analysis approach or solvent-based electrospray ionisation (ESI). Several surface sampling approaches have been developed based on ESI, and those that have been used for intact protein analysis will be discussed below. The extent of protein coverage, top-down elucidation, and probing of protein structure for native proteins and non-covalent complexes will be discussed for each approach. Strategies for improving protein analysis, ranging from sample preparation, and sampling methods to instrument modifications and the inclusion of ion mobility separation in the workflow will also be discussed. The relative benefits and drawbacks of each approach will be summarised, providing an overview of current capabilities.
Collapse
|
5
|
Baghernia H, Seyed Golestan SMJ, Hajiani S, Shokri B, Ghassempour A. Increasing DESI-MS Ion Signal by Plasma Treatment. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:907-916. [PMID: 35522602 DOI: 10.1021/jasms.1c00337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Many studies are focused on using plasma in mass spectrometry as an ionization source or postionization method. In this study, the effect of plasma treatment in the sample preparation step of desorption electrospray ionization (DESI) has been investigated. The plasma treatment of polar samples, including morphine, codeine, captopril, theophylline, fructose, and amphiphilic compounds such as phosphatidylethanolamine (PE) in E. coli bacteria, as well as nonpolar compounds, including thebaine, papaverine, and noscapine, has been followed for ionization efficiency in DESI technique. An atmospheric-pressure glow discharge plasma (GDP) along with the electrospray ionization technique is examined. Plasma treatment before ambient ionization has a dramatic effect on polar and nonpolar sample signals in DESI-TOF mass spectrometry. The intensity of the mass spectrum shows an increase of 1.9-3.4 times for polar compounds, 2.1-2.5 times for nonpolar compounds, and 3.0 times for PE in E. coli bacteria (N = 4). Plasma is a source of reactive atoms, molecules, ions, radicals, and ultraviolet radiation. Plasma surface treatment before DESI analysis by energetic species through momentum/energy transfer yields higher energy surface molecules, leading to more/easier desorption. Under optimal treatment conditions, an improved ion signal intensity is observed without any fragmentation, decomposition, or chemical changes. Ion signals are increased possibly by both increased ionization through protonation of molecules and enhanced subsequent desorption during DESI analysis.
Collapse
Affiliation(s)
- Hasan Baghernia
- Medicinal Plants and Drugs Research Institute, Shahid Beheshti University, G.C., Evin, Tehran 1983969411, Iran
| | | | - Shahedeh Hajiani
- Department of Physics, Shahid Beheshti University, G.C., Evin, Tehran 1983969411, Iran
| | - Babak Shokri
- Department of Physics, Shahid Beheshti University, G.C., Evin, Tehran 1983969411, Iran
- Laser and Plasma Research Institute, Shahid Beheshti University, G.C., Evin, Tehran 1983969411, Iran
| | - Alireza Ghassempour
- Medicinal Plants and Drugs Research Institute, Shahid Beheshti University, G.C., Evin, Tehran 1983969411, Iran
| |
Collapse
|
6
|
Hong Y, Birse N, Quinn B, Montgomery H, Wu D, Rosas da Silva G, van Ruth SM, Elliott CT. Identification of milk from different animal and plant sources by desorption electrospray ionisation high-resolution mass spectrometry (DESI-MS). NPJ Sci Food 2022; 6:14. [PMID: 35149683 PMCID: PMC8837636 DOI: 10.1038/s41538-022-00129-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Accepted: 01/19/2022] [Indexed: 11/09/2022] Open
Abstract
This study used desorption electrospray ionisation mass spectrometry (DESI-MS) to analyse and detect and classify biomarkers in five different animal and plant sources of milk for the first time. A range of differences in terms of features was observed in the spectra of cow milk, goat milk, camel milk, soya milk, and oat milk. Chemometric modelling was then used to classify the mass spectra data, enabling unique or significant markers for each milk source to be identified. The classification of different milk sources was achieved with a cross-validation percentage rate of 100% through linear discriminate analysis (LDA) with high sensitivity to adulteration (0.1-5% v/v). The DESI-MS results from the milk samples analysed show the methodology to have high classification accuracy, and in the absence of complex sample clean-up which is often associated with authenticity testing, to be a rapid and efficient approach for milk fraud control.
Collapse
Affiliation(s)
- Yunhe Hong
- ASSET Technology Centre, Institute for Global Food Security, School of Biological Sciences, Queen's University Belfast, Northern Ireland, UK.
| | - Nicholas Birse
- ASSET Technology Centre, Institute for Global Food Security, School of Biological Sciences, Queen's University Belfast, Northern Ireland, UK
| | - Brian Quinn
- ASSET Technology Centre, Institute for Global Food Security, School of Biological Sciences, Queen's University Belfast, Northern Ireland, UK
| | - Holly Montgomery
- ASSET Technology Centre, Institute for Global Food Security, School of Biological Sciences, Queen's University Belfast, Northern Ireland, UK
| | - Di Wu
- ASSET Technology Centre, Institute for Global Food Security, School of Biological Sciences, Queen's University Belfast, Northern Ireland, UK
| | - Gonçalo Rosas da Silva
- ASSET Technology Centre, Institute for Global Food Security, School of Biological Sciences, Queen's University Belfast, Northern Ireland, UK
| | - Saskia M van Ruth
- Food Quality and Design Group, Wageningen University and Research, western, the Netherlands
| | - Christopher T Elliott
- ASSET Technology Centre, Institute for Global Food Security, School of Biological Sciences, Queen's University Belfast, Northern Ireland, UK
| |
Collapse
|
7
|
Javanshad R, Venter AR. Effects of amino acid additives on protein solubility - insights from desorption and direct electrospray ionization mass spectrometry. Analyst 2021; 146:6592-6604. [PMID: 34586125 DOI: 10.1039/d1an01392k] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Naturally occurring amino acids have been broadly used as additives to improve protein solubility and inhibit aggregation. In this study, improvements in protein signal intensity obtained with the addition of L-serine, and structural analogs, to the desorption electrospray ionization mass spectrometry (DESI-MS) spray solvent were measured. The results were interpreted at the hand of proposed mechanisms of solution additive effects on protein solubility and dissolution. DESI-MS allows for these processes to be studied efficiently using dilute concentrations of additives and small amounts of proteins, advantages that represent real benefits compared to classical methods of studying protein stability and aggregation. We show that serine significantly increases the protein signal in DESI-MS when native proteins are undergoing unfolding during the dissolution process with an acidic solvent system (p-value = 0.0001), or with ammonium bicarbonate under denaturing conditions for proteins with high isoelectric points (p-value = 0.001). We establish that a similar increase in the protein signal cannot be observed with direct ESI-MS, and the observed increase is therefore not related to ionization processes or changes in the physical properties of the bulk solution. The importance of the presence of serine during protein conformational changes while undergoing dissolution is demonstrated through comparisons between the analyses of proteins deposited in native or unfolded states and by using native state-preserving and denaturing desorption solvents. We hypothesize that direct, non-covalent interactions involving all three functional groups of serine are involved in the beneficial effect on protein solubility and dissolution. Supporting evidence for a direct interaction include a reduction in efficacy with D-serine or the racemic mixture, indicating a non-bulk-solution physical property effect; insensitivity to the sample surface type or relative placement of serine addition; and a reduction in efficacy with any modifications to the serine structure, most notably the carboxyl functional group. An alternative hypothesis, also supported by some of our observations, could involve the role of serine clusters in the mechanism of solubility enhancement. Our study demonstrates the capability of DESI-MS together with complementary ESI-MS experiments as a novel tool for understanding protein solubility and dissolution and investigating the mechanism of action for solubility-enhancing additives.
Collapse
Affiliation(s)
- Roshan Javanshad
- Department of Chemistry, Western Michigan University, Kalamazoo, MI 49008-5413, USA.
| | - Andre R Venter
- Department of Chemistry, Western Michigan University, Kalamazoo, MI 49008-5413, USA.
| |
Collapse
|
8
|
Yan B, Bunch J. Probing Folded Proteins and Intact Protein Complexes by Desorption Electrospray Ionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:690-699. [PMID: 33605725 DOI: 10.1021/jasms.0c00417] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Native mass spectrometry (MS) enables the study of intact proteins as well as noncovalent protein-protein and protein-ligand complexes in their biological state. In this work, we present the application of a Waters desorption electrospray ionization (DESI) source with a prototype spray emitter for rapid surface measurements of folded and native protein structures. A comparison of DESI spray solvent shows that adding 50% methanol to 200 mM ammonium acetate solution does not reduce its performance in preserving folded protein structures. Instead, improved signal-to-noise (S/N) ratio is obtained, and less adducted peaks are detected by using this uncommon native MS solvent system. The standard DESI design with an inlet tube allows optimization of sampling temperature conditions to improve desolvation and therefore S/N ratio. Furthermore, tuning the inlet temperature enables the control and study of unfolding behavior of proteins from surface samples. The optimized condition for native DESI has been applied to several selected proteins and protein complexes with the molecular weight ranging from 8.6 to 66.4 kDa. Ions of folded proteins with narrow charge state distribution (CSD), or peaks showing noncovalent-bond-assembled intact protein complexes, are observed in the spectra. Evidence for the structural refolding of denatured proteins and protein complexes sampled with native solvent highlights the need for care when interpreting DESI native MS data, particularly for proteins with stable native structures.
Collapse
Affiliation(s)
- Bin Yan
- National Centre of Excellence in Mass Spectrometry Imaging, National Physical Laboratory, Hampton Road, Teddington TW11 0LW, U.K
| | - Josephine Bunch
- National Centre of Excellence in Mass Spectrometry Imaging, National Physical Laboratory, Hampton Road, Teddington TW11 0LW, U.K
- Department of Metabolism, Digestion and Reproduction, Imperial College London, South Kensington Campus, London SW7 2AZ, U.K
- Rosalind Franklin Institute, Harwell Campus, Didcot OX11 0FA, U.K
| |
Collapse
|
9
|
Wang Y, Jin Q, Shiea J, Sun W. Wire Desorption Combined with Electrospray Ionization Mass Spectrometry: Direct Analysis of Small Organic and Large Biological Compounds. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:1656-1664. [PMID: 32559077 DOI: 10.1021/jasms.0c00107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A novel atmospheric pressure ionization mass spectrometry based on wire desorption and electrospray ionization (WD-ESI) for direct analysis was developed to characterize chemical compounds with different polarities and thermal stabilities at atmospheric pressure. This technique is a variant of the thermal desorption electrospray ion source developed by Shiea et al. One large improvement is that the heating speed (>500 °C/s) of the thermal desorption in this work is extremely fast, using a self-heating metal wire, with which sample solution can splash from the surface to form small droplets and thus the analytes can be protected from thermal decomposition. With this feature, we have successfully achieved soft ionization of highly polar organic and biological compounds such as aflatoxin, small peptides, and even large proteins from complex matrices. The simple structure and self-cleaning capability of the WD-ESI source make it ideal for on-site screening in various applications such as food safety and biodrug testing, especially when coupled with a transportable mass spectrometer.
Collapse
Affiliation(s)
- Yuanlong Wang
- Shimadzu Research Laboratory (Shanghai) Co., Ltd., Shanghai 201206, People's Republic of China
| | - Qiao Jin
- Shimadzu Research Laboratory (Shanghai) Co., Ltd., Shanghai 201206, People's Republic of China
| | - Jentaie Shiea
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan
| | - Wenjian Sun
- Shimadzu Research Laboratory (Shanghai) Co., Ltd., Shanghai 201206, People's Republic of China
| |
Collapse
|
10
|
Hale OJ, Cooper HJ. In situ mass spectrometry analysis of intact proteins and protein complexes from biological substrates. Biochem Soc Trans 2020; 48:317-326. [PMID: 32010951 PMCID: PMC7054757 DOI: 10.1042/bst20190793] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 01/09/2020] [Accepted: 01/09/2020] [Indexed: 12/15/2022]
Abstract
Advances in sample preparation, ion sources and mass spectrometer technology have enabled the detection and characterisation of intact proteins. The challenges associated include an appropriately soft ionisation event, efficient transmission and detection of the often delicate macromolecules. Ambient ion sources, in particular, offer a wealth of strategies for analysis of proteins from solution environments, and directly from biological substrates. The last two decades have seen rapid development in this area. Innovations include liquid extraction surface analysis, desorption electrospray ionisation and nanospray desorption electrospray ionisation. Similarly, developments in native mass spectrometry allow protein-protein and protein-ligand complexes to be ionised and analysed. Identification and characterisation of these large ions involves a suite of hyphenated mass spectrometry techniques, often including the coupling of ion mobility spectrometry and fragmentation techniques. The latter include collision, electron and photon-induced methods, each with their own characteristics and benefits for intact protein identification. In this review, recent developments for in situ protein analysis are explored, with a focus on ion sources and tandem mass spectrometry techniques used for identification.
Collapse
Affiliation(s)
- Oliver J. Hale
- School of Biosciences, University of Birmingham, Edgbaston B15 2TT, U.K
| | - Helen J. Cooper
- School of Biosciences, University of Birmingham, Edgbaston B15 2TT, U.K
| |
Collapse
|
11
|
Unsihuay D, Qiu J, Swaroop S, Nagornov KO, Kozhinov AN, Tsybin YO, Kuang S, Laskin J. Imaging of Triglycerides in Tissues Using Nanospray Desorption Electrospray Ionization (Nano-DESI) Mass Spectrometry. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2020; 448:116269. [PMID: 32863736 PMCID: PMC7453423 DOI: 10.1016/j.ijms.2019.116269] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Nonpolar triglycerides (TGs) are rarely detected in mass spectrometry imaging (MSI) experiments unless they are abundant in the sample. Herein, we use nanospray desorption electrospray ionization (nano-DESI) to explore the role of the solvent composition and ionic dopants on the detection of TGs in a murine gastrocnemius muscle tissue used as a model system. We evaluated three solvent mixtures for their ability to extract nonpolar TG species: MeOH:H2O 9:1 (v/v), MeOH:DCM 6:4 (v/v) and MeOH:AcN:tol 5:3.5:1.5 (v/v/v). We observe that TGs are mainly detected as [M+K]+ adducts and their extraction efficiency is improved using less polar solvents: MeOH:DCM and MeOH:AcN:tol. We also explore whether the ionization efficiency of TGs may be improved by doping the MeOH:AcN:tol solvent with ammonium formate (AF) and other ionic additives. However, the formation of [M+NH4]+ adducts of TGs is less efficient than the formation of [M+K]+ adducts in the range of AF concentrations from 0.1 to 10 mM. Chemical derivatization using 100 μM of Girard T reagent predominately generates reaction products of phosphatidylcholine rather than TG species. Moreover, the presence of the Girard T reagent suppresses ion signals of all the species in the spectrum including TGs. Nano-DESI MSI experiments performed using MeOH:AcN:tol solvent enable imaging of TGs without any detectable adverse effect on signals of other lipids and metabolites. Specifically, 10 out of 14 TG species were detected exclusively using MeOH:AcN:tol and the sensitivity towards other TGs was improved by at least an order of magnitude. Although polyunsaturated TGs may be detected using both solvents, saturated and monounsaturated TGs are only detected using MeOH:AcN:tol. Our results provide a direct path for the improved detection of TGs in tissue imaging experiments using liquid-based ambient ionization techniques.
Collapse
Affiliation(s)
- Daisy Unsihuay
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
| | - Jiamin Qiu
- Department of Animal Sciences, Purdue University, West Lafayette, IN 47907, USA
| | - Sneha Swaroop
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
| | | | | | - Yury O. Tsybin
- Spectroswiss, EPFL Innovation Park, 1015 Lausanne, Switzerland
| | - Shihuan Kuang
- Department of Animal Sciences, Purdue University, West Lafayette, IN 47907, USA
| | - Julia Laskin
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
| |
Collapse
|
12
|
Chen L, Cabot JM, Sanz Rodriguez E, Ghiasvand A, Innis PC, Paull B. Thread-based isoelectric focusing coupled with desorption electrospray ionization mass spectrometry. Analyst 2020; 145:6928-6936. [DOI: 10.1039/d0an01344g] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Efficient ‘on-thread’ isoelectric focusing of proteins, with direct on-thread detection using desorption electrospray ionisation mass spectrometry.
Collapse
Affiliation(s)
- Liang Chen
- ARC Centre of Excellence for Electromaterials Science (ACES)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| | - Joan M. Cabot
- ARC Centre of Excellence for Electromaterials Science (ACES)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| | - Estrella Sanz Rodriguez
- Australian Centre for Research on Separation Science (ACROSS)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| | - Alireza Ghiasvand
- Australian Centre for Research on Separation Science (ACROSS)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| | - Peter C. Innis
- ARC Centre of Excellence for Electromaterials Science (ACES)
- AIIM Facility
- Innovation campus
- University of Wollongong
- Australia
| | - Brett Paull
- ARC Centre of Excellence for Electromaterials Science (ACES)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| |
Collapse
|
13
|
Javanshad R, Maser TL, Honarvar E, Venter AR. The Addition of Polar Organic Solvent Vapors During the Analysis of Proteins by DESI-MS. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:2571-2575. [PMID: 31758521 DOI: 10.1007/s13361-019-02345-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Revised: 09/23/2019] [Accepted: 09/25/2019] [Indexed: 06/10/2023]
Abstract
Exposure of electrospray droplets to organic vapors was shown to dramatically reduce alkali-metal adduction on protein ions and shift protein charge states. Since DESI-MS is affected by similar adduct species as ESI-MS and shares similar ionization mechanisms, polar organic vapor additives should likewise also improve the DESI-MS analysis of proteins. Here the DESI spray was exposed to a variety of polar organic vapor additives. Head space vapors of polar organic solvents were entrained in nitrogen gas and delivered to the atmosphere inside a semi-enclosed plastic enclosure surrounding the spray plume. The vapors of acetone, acetonitrile, ethyl acetate, methanol, and water were investigated. Vapor dependent effects were observed with respect to changes in protein charge state distributions and signal intensities. With ethyl acetate vapor addition, the signal intensities of all proteins investigated were significantly increased, including proteins larger than 25 kDa such as carbonic anhydrase II and bovine serum albumin.
Collapse
Affiliation(s)
- Roshan Javanshad
- Department of Chemistry, Western Michigan University, Kalamazoo, MI, 49008-5413, USA
| | - Tara L Maser
- Department of Chemistry, Western Michigan University, Kalamazoo, MI, 49008-5413, USA
| | - Elahe Honarvar
- Department of Chemistry, Western Michigan University, Kalamazoo, MI, 49008-5413, USA
| | - Andre R Venter
- Department of Chemistry, Western Michigan University, Kalamazoo, MI, 49008-5413, USA.
| |
Collapse
|
14
|
Rahman MM, Chingin K, Chen H. Online desalting and sequential formation of analyte ions for mass spectrometry characterization of untreated biological samples. Chem Commun (Camb) 2019; 55:9188-9191. [DOI: 10.1039/c9cc04705k] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Current-limited high voltage polarity reversing nanoelectrospray ionization allows online separation of intrinsic metal ions in complex biological samples, resulting in the generation of protonated analytes without interference from salt cations.
Collapse
Affiliation(s)
- Md. Matiur Rahman
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation
- East China University of Technology
- Nanchang 330013
- China
| | - Konstantin Chingin
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation
- East China University of Technology
- Nanchang 330013
- China
| | - Huanwen Chen
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation
- East China University of Technology
- Nanchang 330013
- China
| |
Collapse
|