1
|
Das S, Bhatia R. Liquid extraction surface analysis-mass spectrometry: An advanced and environment-friendly analytical tool in modern analysis. J Sep Sci 2022; 45:2746-2765. [PMID: 35579471 DOI: 10.1002/jssc.202100996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 04/23/2022] [Accepted: 05/10/2022] [Indexed: 11/12/2022]
Abstract
The Liquid Extraction Surface Analysis technique is a new high-throughput instrument for ambient mass spectrometry. The benefits of the Liquid Extraction Surface Analysis-Mass Spectrometry approach are the high throughput screening of samples and the absence of sample preparation. Liquid Extraction Surface Analysis-Mass Spectrometry also consumes less solvent for extraction, making it more environmentally friendly and there is no substrate restriction. It utilizes advanced instrumentation like the use of robotic pipettes, nanoelectrospray systems, electronspray ionization chips which makes it highly efficient. In recent years, Liquid Extraction Surface Analysis-Mass Spectrometry has seen widespread use in a variety of analytical fields including drug metabolite analysis, mapping drug distribution in tissues, protein and lipid characterization etc. In this review, we have summarized the basic working principles of the Liquid Extraction Surface Analysis-Mass Spectrometry approach in detail along with a detailed description of the recently reported applications in the analysis of proteins, lipids, drugs and foods. The investigated analytes along with detection methodologies and significant outcomes of various research reports have been presented with the help of tables. This tool has also been utilized in clinical investigations of biological fluids, fingerprint analysis and authentication of agarwood. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Shibam Das
- Department of Pharmaceutical Chemistry & Analysis, ISF College of Pharmacy Moga, Punjab, 142001, India
| | - Rohit Bhatia
- Department of Pharmaceutical Chemistry & Analysis, ISF College of Pharmacy Moga, Punjab, 142001, India
| |
Collapse
|
2
|
Morato NM, Le MT, Holden DT, Graham Cooks R. Automated High-Throughput System Combining Small-Scale Synthesis with Bioassays and Reaction Screening. SLAS Technol 2021; 26:555-571. [PMID: 34697962 DOI: 10.1177/24726303211047839] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The Purdue Make It system is a unique automated platform capable of small-scale in situ synthesis, screening small-molecule reactions, and performing direct label-free bioassays. The platform is based on desorption electrospray ionization (DESI), an ambient ionization method that allows for minimal sample workup and is capable of accelerating reactions in secondary droplets, thus conferring unique advantages compared with other high-throughput screening technologies. By combining DESI with liquid handling robotics, the system achieves throughputs of more than 1 sample/s, handling up to 6144 samples in a single run. As little as 100 fmol/spot of analyte is required to perform both initial analysis by mass spectrometry (MS) and further MSn structural characterization. The data obtained are processed using custom software so that results are easily visualized as interactive heatmaps of reaction plates based on the peak intensities of m/z values of interest. In this paper, we review the system's capabilities as described in previous publications and demonstrate its utilization in two new high-throughput campaigns: (1) the screening of 188 unique combinatorial reactions (24 reaction types, 188 unique reaction mixtures) to determine reactivity trends and (2) label-free studies of the nicotinamide N-methyltransferase enzyme directly from the bioassay buffer. The system's versatility holds promise for several future directions, including the collection of secondary droplets containing the products from successful reaction screening measurements, the development of machine learning algorithms using data collected from compound library screening, and the adaption of a variety of relevant bioassays to high-throughput MS.
Collapse
Affiliation(s)
- Nicolás M Morato
- Department of Chemistry and Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, USA
| | - MyPhuong T Le
- Department of Chemistry and Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, USA
| | - Dylan T Holden
- Department of Chemistry and Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, USA
| | - R Graham Cooks
- Department of Chemistry and Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, USA
| |
Collapse
|
3
|
Heiles S. Advanced tandem mass spectrometry in metabolomics and lipidomics-methods and applications. Anal Bioanal Chem 2021; 413:5927-5948. [PMID: 34142202 PMCID: PMC8440309 DOI: 10.1007/s00216-021-03425-1] [Citation(s) in RCA: 56] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 05/11/2021] [Accepted: 05/19/2021] [Indexed: 12/11/2022]
Abstract
Metabolomics and lipidomics are new drivers of the omics era as molecular signatures and selected analytes allow phenotypic characterization and serve as biomarkers, respectively. The growing capabilities of untargeted and targeted workflows, which primarily rely on mass spectrometric platforms, enable extensive charting or identification of bioactive metabolites and lipids. Structural annotation of these compounds is key in order to link specific molecular entities to defined biochemical functions or phenotypes. Tandem mass spectrometry (MS), first and foremost collision-induced dissociation (CID), is the method of choice to unveil structural details of metabolites and lipids. But CID fragment ions are often not sufficient to fully characterize analytes. Therefore, recent years have seen a surge in alternative tandem MS methodologies that aim to offer full structural characterization of metabolites and lipids. In this article, principles, capabilities, drawbacks, and first applications of these "advanced tandem mass spectrometry" strategies will be critically reviewed. This includes tandem MS methods that are based on electrons, photons, and ion/molecule, as well as ion/ion reactions, combining tandem MS with concepts from optical spectroscopy and making use of derivatization strategies. In the final sections of this review, the first applications of these methodologies in combination with liquid chromatography or mass spectrometry imaging are highlighted and future perspectives for research in metabolomics and lipidomics are discussed.
Collapse
Affiliation(s)
- Sven Heiles
- Institute of Inorganic and Analytical Chemistry, Justus Liebig University Giessen, Heinrich Buff Ring 17, 35392, Giessen, Germany.
| |
Collapse
|
4
|
|
5
|
Le MT, Morato NM, Kaerner A, Welch CJ, Cooks RG. Fragmentation of Polyfunctional Compounds Recorded Using Automated High-Throughput Desorption Electrospray Ionization. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:2261-2273. [PMID: 34280312 DOI: 10.1021/jasms.1c00176] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Using desorption electrospray ionization (DESI) as part of an automated high-throughput system, tandem mass spectra of the compounds in a pharmaceutical library were recorded in the positive mode under standardized conditions. Quality control filtering yielded an MS/MS library of 16 662 spectra. Fragmentation of subsets of the compounds in the library chosen to contain a single instance of a particular functional group (amide, piperazine, sulfonamide) was predicted by experts, and the results were compared with the experimental data. Expert performance was good to excellent for all the cases evaluated. Substituents on the functional groups were found to exert important secondary control over the fragmentation, with the main effect observed being product ion stabilization by aromatic substitution, which was consistent across the different groups evaluated. These substituent effects are generally explicable in terms of standard physical organic chemistry considerations of product ion stability as controlling fragmentation. A somewhat unexpected feature was the incidence of homolytic cleavages, driven by the stability of substituted amine radical cations. The findings of this study are intended to lay the groundwork for machine learning approaches to performing MS/MS spectrum → structure and structure → MS/MS spectrum operations on the same experimental data set. The effort involved and the success achieved in computer-aided interpretation, now underway, will be compared with the expert performance as described here.
Collapse
Affiliation(s)
- MyPhuong T Le
- Department of Chemistry and Bindley Bioscience Center, Purdue University, West Lafayette, Indiana 47907, United States
| | - Nicolás M Morato
- Department of Chemistry and Bindley Bioscience Center, Purdue University, West Lafayette, Indiana 47907, United States
| | - Andreas Kaerner
- Discovery Chemistry Research and Technologies, Eli Lilly and Company, Lilly Corporate Center, Indianapolis, Indiana 46285, United States
| | - Christopher J Welch
- Indiana Consortium for Analytical Science and Engineering (ICASE), Indianapolis, Indiana 46202, United States
| | - R Graham Cooks
- Department of Chemistry and Bindley Bioscience Center, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
6
|
Otsuka Y. Direct Liquid Extraction and Ionization Techniques for Understanding Multimolecular Environments in Biological Systems (Secondary Publication). Mass Spectrom (Tokyo) 2021; 10:A0095. [PMID: 34249586 PMCID: PMC8246329 DOI: 10.5702/massspectrometry.a0095] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 04/21/2021] [Indexed: 11/23/2022] Open
Abstract
A combination of direct liquid extraction using a small volume of solvent and electrospray ionization allows the rapid measurement of complex chemical components in biological samples and visualization of their distribution in tissue sections. This review describes the development of such techniques and their application to biological research since the first reports in the early 2000s. An overview of electrospray ionization, ion suppression in samples, and the acceleration of specific chemical reactions in charged droplets is also presented. Potential future applications for visualizing multimolecular environments in biological systems are discussed.
Collapse
Affiliation(s)
- Yoichi Otsuka
- Graduate School of Science, Osaka University, 1–1 Machikaneyama-cho, Toyonaka, Osaka 560–0043, Japan
- JST, PRESTO, 4–1–8 Honcho, Kawaguchi, Saitama 332–0012, Japan
| |
Collapse
|
7
|
Improved metabolite characterization by liquid chromatography – Tandem mass spectrometry through electron impact type fragments from adduct ions. Anal Chim Acta 2021; 1150:338207. [DOI: 10.1016/j.aca.2021.338207] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 12/22/2020] [Accepted: 01/05/2021] [Indexed: 11/20/2022]
|
8
|
Marzullo BP, Morgan TE, Wootton CA, Perry SJ, Saeed M, Barrow MP, O'Connor PB. Advantages of Two-Dimensional Electron-Induced Dissociation and Infrared Multiphoton Dissociation Mass Spectrometry for the Analysis of Agrochemicals. Anal Chem 2020; 92:11687-11695. [PMID: 32700900 DOI: 10.1021/acs.analchem.0c01585] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Analysis of agrochemicals in an environmental matrix is challenging because these samples contain multiple agrochemicals, their metabolites, degradation products, and endogenous compounds. The analysis of such complex samples is achieved using chromatographic separation techniques coupled to mass spectrometry. Herein, we demonstrate a two-dimensional mass spectrometry (2DMS) technique on a 12 T Fourier transform ion cyclotron resonance mass spectrometer that can analyze a mixture of agrochemicals without using chromatography or quadrupole isolation in a single experiment. The resulting 2DMS contour plot contains abundant tandem MS information for each component in the sample and correlates product ions to their corresponding precursor ions. Two different fragmentation methods are employed, infrared multiphoton dissociation (IRMPD) and electron-induced dissociation (EID), with 2DMS to analyze the mixture of singly charged agrochemicals. The product ions of one of the agrochemicals, pirimiphos-methyl, present in the sample was used to internally calibrate the entire 2DMS spectrum, achieving sub part per million (ppm) to part per billion (ppb) mass accuracies for all species analyzed. The work described in this study will show the advantages of the 2DMS approach, by grouping species with common fragments/core structure and mutual functional groups, using precursor lines and neutral loss lines. In addition, the rich spectral information obtained from IRMPD and EID 2DMS contour plots can accurately identify and characterize agrochemicals.
Collapse
Affiliation(s)
- Bryan P Marzullo
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Tomos E Morgan
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | | | - Simon J Perry
- Product Metabolism & Analytical Sciences, Jealott's Hill International Research Centre, Syngenta, Bracknell, Berkshire RG42 6EY, United Kingdom
| | - Mansoor Saeed
- Product Metabolism & Analytical Sciences, Jealott's Hill International Research Centre, Syngenta, Bracknell, Berkshire RG42 6EY, United Kingdom
| | - Mark P Barrow
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Peter B O'Connor
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, United Kingdom
| |
Collapse
|
9
|
Hale OJ, Cooper HJ. In situ mass spectrometry analysis of intact proteins and protein complexes from biological substrates. Biochem Soc Trans 2020; 48:317-326. [PMID: 32010951 PMCID: PMC7054757 DOI: 10.1042/bst20190793] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 01/09/2020] [Accepted: 01/09/2020] [Indexed: 12/15/2022]
Abstract
Advances in sample preparation, ion sources and mass spectrometer technology have enabled the detection and characterisation of intact proteins. The challenges associated include an appropriately soft ionisation event, efficient transmission and detection of the often delicate macromolecules. Ambient ion sources, in particular, offer a wealth of strategies for analysis of proteins from solution environments, and directly from biological substrates. The last two decades have seen rapid development in this area. Innovations include liquid extraction surface analysis, desorption electrospray ionisation and nanospray desorption electrospray ionisation. Similarly, developments in native mass spectrometry allow protein-protein and protein-ligand complexes to be ionised and analysed. Identification and characterisation of these large ions involves a suite of hyphenated mass spectrometry techniques, often including the coupling of ion mobility spectrometry and fragmentation techniques. The latter include collision, electron and photon-induced methods, each with their own characteristics and benefits for intact protein identification. In this review, recent developments for in situ protein analysis are explored, with a focus on ion sources and tandem mass spectrometry techniques used for identification.
Collapse
Affiliation(s)
- Oliver J. Hale
- School of Biosciences, University of Birmingham, Edgbaston B15 2TT, U.K
| | - Helen J. Cooper
- School of Biosciences, University of Birmingham, Edgbaston B15 2TT, U.K
| |
Collapse
|
10
|
Marzullo BP, Morgan TE, Wootton CA, Li M, Perry SJ, Saeed M, Barrow MP, O'Connor PB. Comparison of Fragmentation Techniques for the Structural Characterization of Singly Charged Agrochemicals. Anal Chem 2020; 92:3143-3151. [PMID: 31909982 DOI: 10.1021/acs.analchem.9b04820] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Investigating the structure of active ingredients, such as agrochemicals and their associated metabolites, is a crucial requisite in the discovery and development of these molecules. In this study, structural characterization by electron-induced dissociation (EID) was compared to collisionally activated dissociation (CAD) on a series of agrochemicals. EID fragmentation produced a greater variety of fragment ions and complementary ion pairs leading to more complete functional group characterization compared to CAD. The results obtained displayed many more cross-ring fragmentation of the pyrimidine ring compared to the pyridine ring. Compounds that consisted of one aromatic heterocyclic moiety (azoxystrobin, fluazifop acid, fluazifop-p-butyl, and pirimiphos-methyl) displayed cross-ring fragmentation while compounds with only aromatic hydrocarbon rings (fenpropidin and S-metolachlor) displayed no cross-ring fragmentation. The advantages of high-resolution accurate mass spectrometry (HRAM MS) are shown with the majority of assignments at ppb range error values and the ability to differentiate ions with the same nominal mass but different elemental composition. This highlights the potential for HRAM MS and EID to be used as a tool for structural characterization of small molecules with a wide variety of functional groups and structural motifs.
Collapse
Affiliation(s)
- Bryan P Marzullo
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| | - Tomos E Morgan
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| | | | - Meng Li
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| | - Simon J Perry
- Syngenta, Jealott's Hill International Research Centre , Product Metabolism & Analytical Sciences , RG42 6EY Berkshire , United Kingdom
| | - Mansoor Saeed
- Syngenta, Jealott's Hill International Research Centre , Product Metabolism & Analytical Sciences , RG42 6EY Berkshire , United Kingdom
| | - Mark P Barrow
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| | - Peter B O'Connor
- Department of Chemistry , University of Warwick , Coventry CV4 7AL , United Kingdom
| |
Collapse
|
11
|
Burns LE, Borts DJ. Rapid untargeted screening for drug residues in animal tissues with liquid microjunction surface sampling probe mass spectrometry. Anal Chim Acta 2019; 1063:75-81. [PMID: 30967188 DOI: 10.1016/j.aca.2019.01.029] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2018] [Revised: 01/13/2019] [Accepted: 01/17/2019] [Indexed: 12/18/2022]
Abstract
An untargeted screening method for the rapid identification of veterinary drug residues in incurred animal tissues using liquid microjunction surface sampling probe mass spectrometry (LMJSSP-MS) was developed. Current analytical methods for veterinary drug residue screening involve lengthy sample preparation, extraction, and instrumental analysis steps. This method identifies veterinary drug residues in several different incurred animal tissues more quickly than conventional analytical methods. This LMJSSP-MS method uses an ambient ionization technology called liquid microjunction surface sampling probe along with a data dependent scan function of a quadrupole orbitrap mass spectrometer. Collected product ion spectra are searched against the mzCloud™ online mass spectral database to identify veterinary drug residues found in incurred animal tissue samples. Examples of veterinary drugs identified with this method include flunixin, tilmicosin, pentobarbital, xylazine, and ketamine. Optimization of method parameters is described and discussed. The limit of identification (LOI) of this method is estimated to be approximately 1 μg g-1 for xylazine and ketamine.
Collapse
Affiliation(s)
- Laura E Burns
- Toxicology Program, Iowa State University, 1800 Christensen Drive, Ames, IA, USA
| | - David J Borts
- Toxicology Program, Iowa State University, 1800 Christensen Drive, Ames, IA, USA; Department of Veterinary Diagnostic and Production Animal Medicine, Iowa State University, 1800 Christensen Drive, Ames, IA, USA.
| |
Collapse
|