1
|
Jarrold MF. Single-Ion Mass Spectrometry for Heterogeneous and High Molecular Weight Samples. J Am Chem Soc 2024; 146:5749-5758. [PMID: 38394699 DOI: 10.1021/jacs.3c08139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2024]
Abstract
In charge detection mass spectrometry (CD-MS) the mass of each individual ion is determined from the measurement of its mass to charge ratio (m/z) and charge. Performing this measurement for thousands of ions allows mass distributions to be measured for heterogeneous and high mass samples that cannot be analyzed by conventional mass spectrometry (MS). CD-MS opens the door to accurate mass measurements for samples into the giga-Dalton regime, vastly expanding the reach of MS and allowing mass distributions to be determined for viruses, gene therapies, and vaccines. Following the success of CD-MS, single-ion mass measurements have recently been performed on an Orbitrap. CD-MS and Orbitrap individual ion mass spectrometry (I2MS) are described. Illustrative examples are provided, and the prospects for higher resolution measurements discussed. In the case of CD-MS, computer simulations indicate that much higher resolving powers are within reach. The ability to perform high-resolution CD-MS analysis of heterogeneous samples will be enabling and disruptive in top-down MS as high-resolution m/z and accurate charge measurements will allow very complex m/z spectra to be unraveled.
Collapse
Affiliation(s)
- Martin F Jarrold
- Chemistry Department, Indiana University, 800 East Kirkwood Avenue, Bloomington, Indiana 47401, United States
| |
Collapse
|
2
|
Parikh RA, Draper BE, Jarrold MF. Multiple Ion Charge Extraction (MICE) for High-Throughput Charge Detection Mass Spectrometry. Anal Chem 2024. [PMID: 38329825 DOI: 10.1021/acs.analchem.3c05087] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/10/2024]
Abstract
Charge detection mass spectrometry (CD-MS) is a single-particle technique, where the masses of individual ions are determined from simultaneous measurements of their mass-to-charge ratio (m/z) and charge. The ions are trapped in an electrostatic linear ion trap (ELIT) and oscillate back and forth through a conducting cylinder connected to a charge-sensitive amplifier. The oscillating ions generate a periodic signal that is processed with fast Fourier transforms (FFTs) to obtain the oscillation frequency (which is related to m/z) and magnitude (which is proportional to the charge). The simultaneous trapping of two or more ions is a way to increase throughput. However, when multiple ions are trapped, it is possible that some of them have overlapping oscillation frequencies, which can lead to an error in the charge determination. To avoid this error, results from overlapping ions are usually discarded. When measurements are performed with many trapped ions, the most abundant m/z species are discarded at a higher rate, which affects the relative abundances in the mass distribution. Here, we report the development of a post-processing method called multiple ion charge extraction (MICE) that uses a statistical approach to assign charges to ions with overlapping frequencies. MICE recovers single-ion information from high signal measurements and makes the relative abundances more resilient to the signal intensity. This approach corrects for high signal m/z biasing, allowing analysis to be faster and more reliable. Using MICE, CD-MS measurements were made at rates of 120 ions/s with little m/z biasing.
Collapse
Affiliation(s)
- Raj A Parikh
- Chemistry Department, Indiana University, 800 E Kirkwood Ave, Bloomington, Indiana 47405, United States
| | - Benjamin E Draper
- Megadalton Solutions Inc., 3750 E Bluebird Ln, Bloomington, Indiana 47401, United States
| | - Martin F Jarrold
- Chemistry Department, Indiana University, 800 E Kirkwood Ave, Bloomington, Indiana 47405, United States
| |
Collapse
|
3
|
Botamanenko DY, Reitenbach DW, Miller LM, Jarrold MF. Electrostatic Linear Ion Trap Optimization Strategy for High Resolution Charge Detection Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:1731-1740. [PMID: 37466262 PMCID: PMC10842736 DOI: 10.1021/jasms.3c00177] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/20/2023]
Abstract
Single ion mass measurements allow mass distributions to be recorded for heterogeneous samples that cannot be analyzed by conventional mass spectrometry. In charge detection mass spectrometry (CD-MS), ions are detected using a conducting cylinder coupled to a charge sensitive amplifier. For optimum performance, the detection cylinder is embedded in an electrostatic linear ion trap (ELIT) where trapped ions oscillate between end-caps that act as opposing ion mirrors. The oscillating ions generate a periodic signal that is analyzed by fast Fourier transforms. The frequency yields the m/z, and the magnitude provides the charge. With a charge precision of 0.2 elementary charges, ions can be assigned to their correct charge states with a low error rate, and the m/z resolving power determines the mass resolving power. Previously, the best mass resolving power achieved with CD-MS was 300. We have recently increased the mass resolving power to 700, through the better optimization of the end-cap potentials. To make a more dramatic improvement in the m/z resolving power, it is necessary to find an ELIT geometry and end-cap potentials that can simultaneously make the ion oscillation frequency independent of both the ion energy and ion trajectory (angular divergence and radial offset) of the entering ion. We describe an optimization strategy that allows these conditions to be met while also adjusting the signal duty cycle to 50% to maximize the signal-to-noise ratio for the charge measurement. The optimized ELIT provides an m/z resolving power of over 300 000 in simulations. Coupled with the high precision charge determination available with CD-MS, this will yield a mass resolving power of 300 000. Such a high mass resolving power will be transformative for the analysis of heterogeneous samples.
Collapse
Affiliation(s)
- Daniel Y Botamanenko
- Chemistry Department, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405
- Megadalton Solutions Inc., 3750 E Bluebird Lane, Bloomington, Indiana 47401
| | - David W Reitenbach
- Chemistry Department, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405
| | - Lohra M Miller
- Chemistry Department, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405
| | - Martin F Jarrold
- Chemistry Department, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405
| |
Collapse
|
4
|
Harper CC, Avadhani VS, Hanozin E, Miller ZM, Williams ER. Dynamic Energy Measurements in Charge Detection Mass Spectrometry Eliminate Adverse Effects of Ion-Ion Interactions. Anal Chem 2023; 95:10077-10086. [PMID: 37343124 PMCID: PMC10389283 DOI: 10.1021/acs.analchem.3c01520] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/23/2023]
Abstract
Ion-ion interactions in charge detection mass spectrometers that use electrostatic traps to measure masses of individual ions have not been reported previously, although ion trajectory simulations have shown that these types of interactions affect ion energies and thereby degrade measurement performance. Here, examples of interactions between simultaneously trapped ions that have masses ranging from ca. 2 to 350 MDa and ca. 100 to 1000 charges are studied in detail using a dynamic measurement method that makes it possible to track the evolution of the mass, charge, and energy of individual ions over their trapping lifetimes. Signals from ions that have similar oscillation frequencies can have overlapping spectral leakage artifacts that result in slightly increased uncertainties in the mass determination, but these effects can be mitigated by the careful choice of parameters used in the short-time Fourier transform analysis. Energy transfers between physically interacting ions are also observed and quantified with individual ion energy measurement resolution as high as ∼950. The mass and charge of interacting ions do not change, and their corresponding measurement uncertainties are equivalent to ions that do not undergo physical interactions. Simultaneous trapping of multiple ions in CDMS can greatly decrease the acquisition time necessary to accumulate a statistically meaningful number of individual ion measurements. These results demonstrate that while ion-ion interactions can occur when multiple ions are trapped, they have negligible effects on mass accuracy when using the dynamic measurement method.
Collapse
Affiliation(s)
- Conner C. Harper
- Department of Chemistry, University of California, Berkeley, California, 94720-1460, United States
| | - Veena S. Avadhani
- Department of Chemistry, University of California, Berkeley, California, 94720-1460, United States
| | - Emeline Hanozin
- Department of Chemistry, University of California, Berkeley, California, 94720-1460, United States
| | - Zachary M. Miller
- Department of Chemistry, University of California, Berkeley, California, 94720-1460, United States
| | - Evan R. Williams
- Department of Chemistry, University of California, Berkeley, California, 94720-1460, United States
| |
Collapse
|
5
|
Abstract
Native mass spectrometry (MS) is aimed at preserving and determining the native structure, composition, and stoichiometry of biomolecules and their complexes from solution after they are transferred into the gas phase. Major improvements in native MS instrumentation and experimental methods over the past few decades have led to a concomitant increase in the complexity and heterogeneity of samples that can be analyzed, including protein-ligand complexes, protein complexes with multiple coexisting stoichiometries, and membrane protein-lipid assemblies. Heterogeneous features of these biomolecular samples can be important for understanding structure and function. However, sample heterogeneity can make assignment of ion mass, charge, composition, and structure very challenging due to the overlap of tens or even hundreds of peaks in the mass spectrum. In this review, we cover data analysis, experimental, and instrumental advances and strategies aimed at solving this problem, with an in-depth discussion of theoretical and practical aspects of the use of available deconvolution algorithms and tools. We also reflect upon current challenges and provide a view of the future of this exciting field.
Collapse
Affiliation(s)
- Amber D. Rolland
- Department of Chemistry and Biochemistry, 1253 University of Oregon, Eugene, OR, USA 97403-1253
| | - James S. Prell
- Department of Chemistry and Biochemistry, 1253 University of Oregon, Eugene, OR, USA 97403-1253
- Materials Science Institute, 1252 University of Oregon, Eugene, OR, USA 97403-1252
| |
Collapse
|
6
|
Abstract
Charge detection mass spectrometry (CDMS) is a single-particle technique where the masses of individual ions are determined from simultaneous measurement of their mass-to-charge ratio (m/z) and charge. Masses are determined for thousands of individual ions, and then the results are binned to give a mass spectrum. Using this approach, accurate mass distributions can be measured for heterogeneous and high-molecular-weight samples that are usually not amenable to analysis by conventional mass spectrometry. Recent applications include heavily glycosylated proteins, protein complexes, protein aggregates such as amyloid fibers, infectious viruses, gene therapies, vaccines, and vesicles such as exosomes.
Collapse
Affiliation(s)
- Martin F Jarrold
- Chemistry Department, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47404, United States
| |
Collapse
|
7
|
Todd AR, Barnes LF, Young K, Zlotnick A, Jarrold MF. Higher Resolution Charge Detection Mass Spectrometry. Anal Chem 2020; 92:11357-11364. [PMID: 32806905 PMCID: PMC8587657 DOI: 10.1021/acs.analchem.0c02133] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Charge detection mass spectrometry is a single particle technique where the masses of individual ions are determined from simultaneous measurements of each ion's m/z ratio and charge. The ions pass through a conducting cylinder, and the charge induced on the cylinder is detected. The cylinder is usually placed inside an electrostatic linear ion trap so that the ions oscillate back and forth through the cylinder. The resulting time domain signal is analyzed by fast Fourier transformation; the oscillation frequency yields the m/z, and the charge is determined from the magnitudes. The mass resolving power depends on the uncertainties in both quantities. In previous work, the mass resolving power was modest, around 30-40. In this work we report around an order of magnitude improvement. The improvement was achieved by coupling high-accuracy charge measurements (obtained with dynamic calibration) with higher resolution m/z measurements. The performance was benchmarked by monitoring the assembly of the hepatitis B virus (HBV) capsid. The HBV capsid assembly reaction can result in a heterogeneous mixture of intermediates extending from the capsid protein dimer to the icosahedral T = 4 capsid with 120 dimers. Intermediates of all possible sizes were resolved, as well as some overgrown species. Despite the improved mass resolving power, the measured peak widths are still dominated by instrumental resolution. Heterogeneity makes only a small contribution. Resonances were observed in some of the m/z spectra. They result from ions with different masses and charges having similar m/z values. Analogous resonances are expected whenever the sample is a heterogeneous mixture assembled from a common building block.
Collapse
|
8
|
Todd AR, Jarrold MF. Dramatic Improvement in Sensitivity with Pulsed Mode Charge Detection Mass Spectrometry. Anal Chem 2019; 91:14002-14008. [PMID: 31589418 PMCID: PMC6834878 DOI: 10.1021/acs.analchem.9b03586] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Charge detection mass spectrometry (CDMS) is emerging as a valuable tool to determine mass distributions for heterogeneous and high-mass samples. It is a single-particle technique where masses are determined for individual ions from simultaneous measurements of their mass-to-charge ratio (m/z) and charge. Ions are trapped in an electrostatic linear ion trap (ELIT) and oscillate back and forth through a detection cylinder. The trap is open and able to trap ions for a small fraction of the total measurement time so most of the ions (>99.8%) in a continuous ion beam are lost. Here, we implement an ion storage scheme where ions are accumulated and stored in a hexapole and then injected into the ELIT at the right time for them to be trapped. This pulsed mode of operation increases the sensitivity of CDMS by more than 2 orders of magnitude, which allows much lower titer samples to be analyzed. A limit of detection of 3.3 × 108 particles/mL was obtained for hepatitis B virus T = 4 capsids with a 1.3 μL sample. The hexapole where the ions are accumulated and stored is a significant distance from the ion trap so ions are dispersed in time by their m/z values as they travel between the hexapole and the ELIT. By varying the delay time between ion release and trapping, different windows of m/z values can be trapped.
Collapse
Affiliation(s)
- Aaron R. Todd
- Chemistry Department, Indiana University, 800 East Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Martin F. Jarrold
- Chemistry Department, Indiana University, 800 East Kirkwood Avenue, Bloomington, Indiana 47405, United States
| |
Collapse
|