1
|
Mascolini MV, Toniolo I, Carniel EL, Fontanella CG. Ex vivo, in vivo and in silico studies of corneal biomechanics: a systematic review. Phys Eng Sci Med 2024; 47:403-441. [PMID: 38598066 PMCID: PMC11166853 DOI: 10.1007/s13246-024-01403-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 02/08/2024] [Indexed: 04/11/2024]
Abstract
Healthy cornea guarantees the refractive power of the eye and the protection of the inner components, but injury, trauma or pathology may impair the tissue shape and/or structural organization and therefore its material properties, compromising its functionality in the ocular visual process. It turns out that biomechanical research assumes an essential role in analysing the morphology and biomechanical response of the cornea, preventing pathology occurrence, and improving/optimising treatments. In this review, ex vivo, in vivo and in silico methods for the corneal mechanical characterization are reported. Experimental techniques are distinct in testing mode (e.g., tensile, inflation tests), samples' species (human or animal), shape and condition (e.g., healthy, treated), preservation methods, setup and test protocol (e.g., preconditioning, strain rate). The meaningful results reported in the pertinent literature are discussed, analysing differences, key features and weaknesses of the methodologies adopted. In addition, numerical techniques based on the finite element method are reported, incorporating the essential steps for the development of corneal models, such as geometry, material characterization and boundary conditions, and their application in the research field to extend the experimental results by including further relevant aspects and in the clinical field for diagnostic procedure, treatment and planning surgery. This review aims to analyse the state-of-art of the bioengineering techniques developed over the years to study the corneal biomechanics, highlighting their potentiality to improve diagnosis, treatment and healing process of the corneal tissue, and, at the same, pointing out the current limits in the experimental equipment and numerical tools that are not able to fully characterize in vivo corneal tissues non-invasively and discourage the use of finite element models in daily clinical practice for surgical planning.
Collapse
Affiliation(s)
- Maria Vittoria Mascolini
- Department of Industrial Engineering, University of Padova, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Padova, Italy
| | - Ilaria Toniolo
- Department of Industrial Engineering, University of Padova, Padova, Italy.
- Centre for Mechanics of Biological Materials, University of Padova, Padova, Italy.
| | - Emanuele Luigi Carniel
- Department of Industrial Engineering, University of Padova, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Padova, Italy
| | - Chiara Giulia Fontanella
- Department of Industrial Engineering, University of Padova, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Padova, Italy
| |
Collapse
|
2
|
Foster WJ, Berg BW, Luminais SN, Hadayer A, Schaal S. Computational Modeling of Ophthalmic Procedures: Computational Modeling of Ophthalmic Procedures. Am J Ophthalmol 2022; 241:87-107. [PMID: 35358485 PMCID: PMC9444883 DOI: 10.1016/j.ajo.2022.03.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 01/16/2022] [Accepted: 03/17/2022] [Indexed: 11/01/2022]
Abstract
PURPOSE To explore how finite-element calculations can continue to contribute to diverse problems in ophthalmology and vision science, we describe our recent work on modeling the force on the peripheral retina in intravitreal injections and how that force increases with shorter, smaller gauge needles. We also present a calculation that determines the location and stress on a retinal pigment epithelial detachment during an intravitreal injection, the possibility that stress induced by the injection can lead to a tear of the retinal pigment epithelium. BACKGROUND Advanced computational models can provide a critical insight into the underlying physics in many surgical procedures, which may not be intuitive. METHODS The simulations were implemented using COMSOL Multiphysics. We compared the monkey retinal adhesive force of 18 Pa with the results of this study to quantify the maximum retinal stress that occurs during intravitreal injections. CONCLUSIONS Currently used 30-gauge needles produce stress on the retina during intravitreal injections that is only slightly below the limit that can create retinal tears. As retina specialists attempt to use smaller needles, the risk of complications may increase. In addition, we find that during an intravitreal injection, the stress on the retina in a pigment epithelial detachment occurs at the edge of the detachment (found clinically), and the stress is sufficient to tear the retina. These findings may guide physicians in future clinical research. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.
Collapse
Affiliation(s)
- William J Foster
- From the Department of Bioengineering (W.J.F.), Lewes Katz School of Medicine (B.W.B., S.N.L.), Temple University, Philadelphia, Pennsylvania, USA; Altasciences, Montréal, Québec, Canada (W.J.F.).
| | - Brian W Berg
- From the Department of Bioengineering (W.J.F.), Lewes Katz School of Medicine (B.W.B., S.N.L.), Temple University, Philadelphia, Pennsylvania, USA
| | - Steven N Luminais
- From the Department of Bioengineering (W.J.F.), Lewes Katz School of Medicine (B.W.B., S.N.L.), Temple University, Philadelphia, Pennsylvania, USA
| | - Amir Hadayer
- Department of Ophthalmology, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel (A.H.)
| | - Shlomit Schaal
- Department of Ophthalmology, University of Massachusetts Medical School, Worcester, Massachusetts, USA (S.S.)
| |
Collapse
|
3
|
Pagano L, Shah H, Al Ibrahim O, Gadhvi KA, Coco G, Lee JW, Kaye SB, Levis HJ, Hamill KJ, Semeraro F, Romano V. Update on Suture Techniques in Corneal Transplantation: A Systematic Review. J Clin Med 2022; 11:1078. [PMID: 35207352 PMCID: PMC8877912 DOI: 10.3390/jcm11041078] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 02/15/2022] [Accepted: 02/15/2022] [Indexed: 02/06/2023] Open
Abstract
Effective suturing remains key to achieving successful outcomes in corneal surgery, especially anterior lamellar keratoplasty and full thickness transplantation. Limitations in the technique may result in complications such as wound leak, infection, or high astigmatism post corneal graft. By using a systematic approach, this study reviews articles and conducts content analysis based on update 2020 PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria). The aim of this paper is to summarize the state of the art of corneal suturing techniques for every type of corneal transplant and patient age and also their outcomes regarding astigmatism and complications. Future developments for corneal transplantation will be also discussed. This is important because especially the young surgeon must have knowledge of the implications of every suture performed in order to achieve consistent and predictable post-operative outcomes and also be aware of all the possible complications.
Collapse
Affiliation(s)
- Luca Pagano
- St. Paul’s Eye Unit, Royal Liverpool University Hospital, Liverpool L7 8XP, UK; (H.S.); (K.A.G.); (G.C.); (J.W.L.); (S.B.K.)
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, 20090 Milan, Italy
| | - Haider Shah
- St. Paul’s Eye Unit, Royal Liverpool University Hospital, Liverpool L7 8XP, UK; (H.S.); (K.A.G.); (G.C.); (J.W.L.); (S.B.K.)
| | - Omar Al Ibrahim
- Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, Ophthalmology Clinic, University of Brescia, 25121 Brescia, Italy; (O.A.I.); (F.S.); (V.R.)
| | - Kunal A. Gadhvi
- St. Paul’s Eye Unit, Royal Liverpool University Hospital, Liverpool L7 8XP, UK; (H.S.); (K.A.G.); (G.C.); (J.W.L.); (S.B.K.)
| | - Giulia Coco
- St. Paul’s Eye Unit, Royal Liverpool University Hospital, Liverpool L7 8XP, UK; (H.S.); (K.A.G.); (G.C.); (J.W.L.); (S.B.K.)
| | - Jason W. Lee
- St. Paul’s Eye Unit, Royal Liverpool University Hospital, Liverpool L7 8XP, UK; (H.S.); (K.A.G.); (G.C.); (J.W.L.); (S.B.K.)
- School of Medicine, University of Liverpool, Liverpool L69 3BX, UK
| | - Stephen B. Kaye
- St. Paul’s Eye Unit, Royal Liverpool University Hospital, Liverpool L7 8XP, UK; (H.S.); (K.A.G.); (G.C.); (J.W.L.); (S.B.K.)
- Department of Eye and Vision Science, University of Liverpool, Liverpool L69 3BX, UK; (H.J.L.); (K.J.H.)
| | - Hannah J. Levis
- Department of Eye and Vision Science, University of Liverpool, Liverpool L69 3BX, UK; (H.J.L.); (K.J.H.)
| | - Kevin J. Hamill
- Department of Eye and Vision Science, University of Liverpool, Liverpool L69 3BX, UK; (H.J.L.); (K.J.H.)
| | - Francesco Semeraro
- Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, Ophthalmology Clinic, University of Brescia, 25121 Brescia, Italy; (O.A.I.); (F.S.); (V.R.)
| | - Vito Romano
- Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, Ophthalmology Clinic, University of Brescia, 25121 Brescia, Italy; (O.A.I.); (F.S.); (V.R.)
- Department of Eye and Vision Science, University of Liverpool, Liverpool L69 3BX, UK; (H.J.L.); (K.J.H.)
| |
Collapse
|
4
|
Deshmukh R, Nair S, Vaddavalli PK, Agrawal T, Rapuano CJ, Beltz J, Vajpayee RB. Post-penetrating keratoplasty astigmatism. Surv Ophthalmol 2021; 67:1200-1228. [PMID: 34808143 DOI: 10.1016/j.survophthal.2021.11.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Revised: 11/06/2021] [Accepted: 11/15/2021] [Indexed: 10/19/2022]
Abstract
Postoperative astigmatism is one of the common complications affecting visual outcomes after a penetrating keratoplasty. It can result from various factors related to host, donor and surgical technique, resulting in suboptimal visual outcome. While some of the measures taken during preoperative planning and during actual surgery can reduce the magnitude of postoperative astigmatism, postoperative correction of astigmatism is often required in cases with high degrees of astigmatism. When spectacles and contact lenses fail to provide optimal visual outcomes, various surgical techniques that include astigmatic keratotomy, compression sutures, toric intraocular lens placement, and laser refractive procedures can be considered. When none of these techniques are able to achieve a desired result with in the acceptable optical range, a repeat keratoplasty is considered a last option. We discuss the various causes and management of complication of postoperative astigmatism occurring after a full thickness corneal transplantation surgery.
Collapse
Affiliation(s)
| | - Sridevi Nair
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, Delhi, India
| | | | - Tushar Agrawal
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, Delhi, India
| | | | | | - Rasik B Vajpayee
- Royal Victorian Eye and Ear Hospital, Melbourne, Australia; Vision Eye Institute, Melbourne, Australia; University of Melbourne, Australia
| |
Collapse
|
5
|
Kim WH, Hong K, Lim D, Lee JH, Jung YJ, Kim B. Optimal Position of Attachment for Removable Thermoplastic Aligner on the Lower Canine Using Finite Element Analysis. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E3369. [PMID: 32751305 PMCID: PMC7436137 DOI: 10.3390/ma13153369] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 07/21/2020] [Accepted: 07/27/2020] [Indexed: 01/08/2023]
Abstract
Malocclusion is considered as a developmental disorder rather than a disease, and it may be affected by the composition and proportions of masseter muscle fibers. Orthodontics is a specialty of dentistry that deals with diagnosis and care of various irregular bite and/or malocclusion. Recent developments of 3D scanner and 3D printing technology has led to the use of a removable thermoplastic aligner (RTA), which is widely used due to its aesthetic excellence, comfortableness, and time efficiency. However, orthodontics using only an RTA has lower treatment efficacy and accuracy due to the differing movement of teeth from the plan. In order to improve these disadvantages, attachments were used, and biomechanical analyses were performed with and without them. However, there is insufficient research on the movement of teeth and the transfer of load according to the attachment position and shape. Therefore, in our study, we aimed to identify the optimal shape and position of attachments by analyzing various shapes and positions of attachments. Through 3D finite element analysis (FEA), simple tooth shape and mandibular canine shape were extracted in order to construct the orthodontics model which took into account the various shapes and positions of attachments. The optimal shape of a cylinder was derived through the FEA of simple tooth shape and analyzing various positions of attachments on teeth revealed that fixing the attachments at the lingual side of the tooth rather than the buccal side allowed for torque control and an effective movement of the teeth. Therefore, we suggest fixing the attachments at the lingual side rather than the buccal side of the tooth to induce effective movement of teeth in orthodontic treatment with the RTA in case of canine teeth.
Collapse
Affiliation(s)
- Won-Hyeon Kim
- Clinical Translational Research Center for Dental Science, Seoul National University Dental Hospital, Seoul 03080, Korea;
- Department of Mechanical Engineering, Sejong University, Seoul 05006, Korea;
| | | | - Dohyung Lim
- Department of Mechanical Engineering, Sejong University, Seoul 05006, Korea;
| | - Jong-Ho Lee
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Seoul National University, Seoul 03080, Korea;
| | - Yu Jin Jung
- Research Center for Advanced Specialty Chemicals, Korea Research Institute of Chemical Technology, Ulsan 44412, Korea
| | - Bongju Kim
- Clinical Translational Research Center for Dental Science, Seoul National University Dental Hospital, Seoul 03080, Korea;
| |
Collapse
|