1
|
Guo Y, Liu X, Li R, Ng S, Liu Q, Wang L, Hu P, Ren K, Jiang J, Fan J, He Y, Zhu Q, Lin X, Li H, Wang J. Comparison of downsizing strategy (HANGZHOU Solution) and standard annulus sizing strategy in type 0 bicuspid aortic stenosis patients undergoing transcatheter aortic valve replacement: Rationale and design of a randomized clinical trial. Am Heart J 2024; 274:65-74. [PMID: 38701961 DOI: 10.1016/j.ahj.2024.04.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 04/21/2024] [Accepted: 04/21/2024] [Indexed: 05/06/2024]
Abstract
BACKGROUND There has not been a consensus on the prothesis sizing strategy in type 0 bicuspid aortic stenosis (AS) patients undergoing transcatheter aortic valve replacement (TAVR). Modifications to standard annular sizing strategies might be required due to the distinct anatomical characteristics. We have devised a downsizing strategy for TAVR using a self-expanding valve specifically for patients with type 0 bicuspid AS. The primary aim of this study is to compare the safety and efficacy of downsizing strategy with the Standard Annulus Sizing Strategy in TAVR for patients with type 0 bicuspid AS. TRIAL DESIGN It is a prospective, multi-center, superiority, single-blinded, randomized controlled trial comparing the Down Sizing and Standard Annulus Sizing Strategy in patients with type 0 bicuspid aortic stenosis undergoing transcatheter aortic valve replacement. Eligible participants will include patients with severe type 0 bicuspid AS, as defined by criteria such as mean gradient across aortic valve ≥40 mmHg, peak aortic jet velocity ≥4.0 m/s, aortic valve area (AVA) ≤1.0 cm², or AVA index ≤0.6 cm2/m2. These patients will be randomly assigned, in a 1:1 ratio, to either the Down Sizing Strategy group or the Standard Sizing Strategy group. In the Down Sizing Strategy group, a valve one size smaller will be implanted if the "waist sign" manifests along with less than mild regurgitation during balloon pre-dilatation. The primary end point of the study is a composite of VARC-3 defined device success, absence of both permanent pacemaker implantation due to high-degree atrioventricular block and new-onset complete left bundle branch block. CONCLUSION This study will compare the safety and efficacy of Down Sizing Strategy with the Standard Annulus Sizing Strategy and provide valuable insights into the optimal approach for sizing in TAVR patients with type 0 bicuspid AS. We hypothesize that the Down Sizing Strategy will demonstrate superiority when compared to the Standard Annulus Sizing Strategy. (Down Sizing Strategy (HANGZHOU Solution) vs Standard Sizing Strategy TAVR in Bicuspid Aortic Stenosis (Type 0) (TAILOR-TAVR), NCT05511792).
Collapse
Affiliation(s)
- Yuchao Guo
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China
| | - Xianbao Liu
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China; Research Center for Life Science and Human Health, Binjiang Institute of Zhejiang University, Hangzhou 310053, China
| | - Ranxi Li
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China
| | - Stella Ng
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China
| | - Qiong Liu
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China
| | - Lihan Wang
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China
| | - Po Hu
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China
| | - Kaida Ren
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China
| | - Jubo Jiang
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China
| | - Jiaqi Fan
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China
| | - Yuxin He
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China
| | - Qifeng Zhu
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China
| | - Xinping Lin
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China
| | - Huajun Li
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China
| | - Jian'an Wang
- Department of Cardiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou 310009, China; Research Center for Life Science and Human Health, Binjiang Institute of Zhejiang University, Hangzhou 310053, China.
| |
Collapse
|
2
|
Gutierrez L, Boiago M, De Biase C, Oliva O, Laforgia P, Feliachi S, Beneduce A, Dumonteil N, Tchetche D. Transcatheter Aortic Valve Implantation for Bicuspid Aortic Valve Disease: Procedural Planning and Clinical Outcomes. J Clin Med 2023; 12:7074. [PMID: 38002687 PMCID: PMC10672483 DOI: 10.3390/jcm12227074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 10/15/2023] [Accepted: 10/24/2023] [Indexed: 11/26/2023] Open
Abstract
Bicuspid aortic valve (BAV) is the most common congenital heart disease, with a prevalence of 1-2% and occurring in >20% of octogenarians referred for aortic valve replacement. However, BAV patients have been systematically excluded from pivotal randomized trials. Since TAVI indications are moving toward low-risk patients, an increase in the number of BAV patients who undergo TAVI is expected. BAV represents a challenge due to its unique morphological features (raphe, extreme asymmetrical valve calcifications, cusp asymmetry and aortopathy) and the lack of consensus about the accurate sizing method. The role of multi-slice computed tomography (MSCT) in the planification of the TAVI procedure is well-established, being useful to define the optimal valve sizing and the implantation strategy. New-generation devices, more experience of the operators and better planification of the procedure have been associated with similar clinical outcomes in bicuspid and tricuspid patients undergoing TAVI.
Collapse
Affiliation(s)
- Lola Gutierrez
- Groupe Cardiovasculaire Interventionnel (GCVI), Clinique Pasteur, 31300 Toulouse, France; (M.B.); (C.D.B.); (O.O.); (P.L.); (S.F.); (A.B.); (N.D.); (D.T.)
| | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Dayawansa NH, Noaman S, Teng LE, Htun NM. Transcatheter Aortic Valve Therapy for Bicuspid Aortic Valve Stenosis. J Cardiovasc Dev Dis 2023; 10:421. [PMID: 37887868 PMCID: PMC10607300 DOI: 10.3390/jcdd10100421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 10/01/2023] [Accepted: 10/07/2023] [Indexed: 10/28/2023] Open
Abstract
Transcatheter aortic valve implantation (TAVI) has become first-line treatment for older adults with severe aortic stenosis (AS), however, patients with bicuspid aortic valve (BAV) have been traditionally excluded from randomised trials and guidelines. As familiarity and proficiency of TAVI operators have improved, case-series and observational data have demonstrated the feasibility of successful TAVI in bicuspid aortic valve aortic stenosis (BAV-AS), however, patients with BAV-AS have several distinct characteristics that influence the likelihood of TAVI success. This review aims to summarise the pathophysiology and classification of BAV, published safety data, anatomical challenges and procedural considerations essential for pre-procedural planning, patient selection and procedural success of TAVI in BAV.
Collapse
Affiliation(s)
- Nalin H. Dayawansa
- Alfred Health, Melbourne, VIC 3004, Australia; (N.H.D.); (S.N.); (L.E.T.)
- Department of Medicine, Central Clinical School, Monash University, Melbourne, VIC 3004, Australia
- Baker Heart & Diabetes Institute, Melbourne, VIC 3004, Australia
| | - Samer Noaman
- Alfred Health, Melbourne, VIC 3004, Australia; (N.H.D.); (S.N.); (L.E.T.)
- Western Health, St Albans, VIC 3021, Australia
| | - Lung En Teng
- Alfred Health, Melbourne, VIC 3004, Australia; (N.H.D.); (S.N.); (L.E.T.)
| | - Nay Min Htun
- Alfred Health, Melbourne, VIC 3004, Australia; (N.H.D.); (S.N.); (L.E.T.)
- Peninsula Health, Frankston, VIC 3199, Australia
| |
Collapse
|
4
|
Gupta R, Mahmoudi E, Behnoush AH, Malik AH, Mahajan P, Lin M, Bandyopadhyay D, Goel A, Chakraborty S, Aedma SK, Gupta HB, Vyas AV, Combs WG, Mathur M, Yakubov SJ, Patel NC. Clinical outcomes and the impact of valve morphology for transcatheter aortic valve replacement in bicuspid aortic valves: A systematic review and meta-analysis. Catheter Cardiovasc Interv 2023; 102:721-730. [PMID: 37605512 DOI: 10.1002/ccd.30808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 05/16/2023] [Accepted: 08/13/2023] [Indexed: 08/23/2023]
Abstract
BACKGROUND Bicuspid aortic valve (BAV) is present in approximately 0.5%-2% of the general population, causing significant aortic stenosis (AS) in 12%-37% of affected individuals. Transcatheter aortic valve replacement (TAVR) is being considered the treatment of choice in patients with symptomatic AS across all risk spectra. AIM Aim Our study aims to compare TAVR outcomes in patients with BAV versus tricuspid aortic valves (TAV). METHODS A comprehensive literature search was performed in PubMed, Web of Science, and Cochrane trials. Studies were included if they included BAV and TAV patients undergoing TAVR with quantitative data available for at least one of our predefined outcomes. Meta-analysis was performed by the random-effects model using Stata software. RESULTS Fifty studies of 203,288 patients were included. BAV patients had increased 30-day all-cause mortality (odds ratio [OR] = 1.23 [1.00-1.50], p = 0.05), in-hospital stroke (OR = 1.39 [1.01-1.93], p = 0.05), in-hospital and 30-day PPI (OR = 1.13 [1.00-1.27], p = 0.04; OR = 1.16 [1.04-1.13], p = 0.01) and in-hospital, 30-day and 1-year aortic regurgitation (AR) (OR = 1.48 [1.19-1.83], p < 0.01; OR = 1.79 [1.26-2.52], p < 0.01; OR = 1.64 [1.03-2.60], p = 0.04). Subgroup analysis on new-generation valves showed a reduced 1-year all-cause mortality (OR = 0.86 [CI = 0.75-0.98], p = 0.03), despite higher in-hospital and 30-day PPI (OR = 0.1.21 [1.04-1.41], p = 0.01; OR = 1.17 [1.05-1.31], p = 0.01) and in-hospital AR (OR = 1.62 [1.14-2.31], p = 0.01) in the BAV group. The quality of included studies was moderate-to-high, and only three analyses presented high heterogeneity. CONCLUSION TAVR is associated with comparable outcomes in patients with BAV and TAV. Careful selection of BAV cases by preprocedural assessment of valve anatomy and burden of calcification, pre- and post-procedural dilation, and implementing newer generations of valves may improve the safety and efficacy of TAVR in BAV patients.
Collapse
Affiliation(s)
- Rahul Gupta
- Lehigh Valley Heart Institute, Lehigh Valley Health Network, Allentown, Pennsylvania, USA
| | - Elham Mahmoudi
- Universal Scientific Education and Research Network, Tehran University of Medical Sciences, Tehran, Iran
| | | | - Aaqib H Malik
- Department of Cardiology, Westchester Medical Center and New York Medical College, Valhalla, New York, USA
| | - Pranav Mahajan
- Department of Medicine, Carle Foundation Hospital, Urbana, Illinois, USA
| | - Muling Lin
- Morsani College of Medicine, University of South Florida, Tampa, Florida, USA
| | - Dhrubajyoti Bandyopadhyay
- Department of Cardiology, Westchester Medical Center and New York Medical College, Valhalla, New York, USA
| | - Akshay Goel
- Department of Cardiology, Westchester Medical Center and New York Medical College, Valhalla, New York, USA
| | - Sandipan Chakraborty
- Department of Cardiology, Westchester Medical Center and New York Medical College, Valhalla, New York, USA
| | - Surya K Aedma
- Department of Medicine, Carle Foundation Hospital, Urbana, Illinois, USA
| | - Harsh Bala Gupta
- Guru Nanak Dev Hospital, Department of medicine, Government Medical College, Amritsar, Punjab, India
| | - Apurva V Vyas
- Lehigh Valley Heart Institute, Lehigh Valley Health Network, Allentown, Pennsylvania, USA
| | - William G Combs
- Lehigh Valley Heart Institute, Lehigh Valley Health Network, Allentown, Pennsylvania, USA
| | - Moses Mathur
- Heart & Vascular Institute, Penn State Health, Milton S. Hershey Medical Center, Hershey, Pennsylvania, USA
| | - Steven J Yakubov
- Department of Interventional Cardiology, Riverside Methodist-Ohio Health, Columbus, Ohio, USA
| | - Nainesh C Patel
- Lehigh Valley Heart Institute, Lehigh Valley Health Network, Allentown, Pennsylvania, USA
| |
Collapse
|
5
|
Deutsch O, Vitanova K, Ruge H, Erlebach M, Krane M, Lange R. Results of new-generation balloon vs. self-expandable transcatheter heart valves for bicuspid aortic valve stenosis. Front Cardiovasc Med 2023; 10:1252163. [PMID: 37727303 PMCID: PMC10505722 DOI: 10.3389/fcvm.2023.1252163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 08/17/2023] [Indexed: 09/21/2023] Open
Abstract
Background Data comparing new-generation self-expandable (SEV, Evolut R/PRO) vs. balloon-expandable (BEV, SAPIEN 3/3Ultra) transcatheter heart valve replacement (TAVR) in bicuspid aortic valve stenosis (BAV) is limited. Our aim was to compare 30-day results of SEV and BEV implantations in patients with BAV. Methods A total of 2009 patients underwent TAVR between April 2015 and June 2021 at our Centre. From our institutional registry, we identified 106 consecutive patients with BAV who underwent TAVR using SEV and BEV. Results A 106 patients (n = 68 BEV; n = 38 SEV) were included. Mean age was 74.6 ± 8.8 years (BEV) vs.75.3 ± 8.7 years (SEV) (p = 0.670) and Society of Thoracic Surgeons score was 2.6 ± 1.9 (BEV) vs. 2.6 ± 1.6 (SEV) (p = 0.374), respectively. Device landing zone calcium volume (DLZ-CV) was 1168 ± 811 vs. 945 ± 850 mm3 (p = 0.192). Valve Academic Research Consortium (VARC)-3 device success at 30 days was similar (BEV 80.9% vs. SEV 86.8%; p = 0.433). More post-dilatations were performed in SEVs (23.5% BEV vs. 52.6% SEV; p = 0.002). Overall mean gradient at 30 days follow-up was 11.9 ± 4.6 mmHG (BEV) vs. 9.2 ± 3.0 mmHG (SEV) (p = 0.002). A mild-moderate degree of paravalvular leak (PVL) was detected more often in the SEV group (7.4% vs. 13.2%; p = 0.305). A trend towards higher rate of permanent pacemaker implantation was observed in SEV (11.8% vs. 23.7%; p = 0.109). Conclusions Treatment of BAV revealed similar performance using BEV and SEV. In this retrospective cohort study, hemodynamics were more favorable with the SEV, although there was a trend toward more PVL and significantly more post-dilations.
Collapse
Affiliation(s)
- Oliver Deutsch
- Department of Cardiovascular Surgery, German Heart Centre Munich, Munich, Germany
| | - Keti Vitanova
- Department of Cardiovascular Surgery, German Heart Centre Munich, Munich, Germany
| | - Hendrik Ruge
- Department of Cardiovascular Surgery, German Heart Centre Munich, Munich, Germany
| | - Magdalena Erlebach
- Department of Cardiovascular Surgery, German Heart Centre Munich, Munich, Germany
| | - Markus Krane
- Department of Surgery, Division of Cardiac Surgery, Yale School of Medicine, New Haven, CT, United States
| | - Rüdiger Lange
- Department of Cardiovascular Surgery, German Heart Centre Munich, Munich, Germany
| |
Collapse
|
6
|
Tobe A, Tanaka A, Tokuda Y, Shirai Y, Miyazaki T, Yuhara S, Akita S, Furusawa K, Ishii H, Mutsuga M, Murohara T. Transcatheter Aortic Valve Replacement for Bicuspid Aortic Stenosis With a Severely Calcified Raphe Using An Under-Sized SAPIEN 3 Valve: Sizing by the Circle Method and Deployment by the Pressure-Regulated Method. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2023; 53S:S149-S152. [PMID: 36031540 DOI: 10.1016/j.carrev.2022.08.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2022] [Revised: 08/17/2022] [Accepted: 08/18/2022] [Indexed: 11/24/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) for bicuspid aortic valve stenosis is challenging, and the absence of established methods for sizing the bicuspid aortic valve (BAV) complicates TAVR. We report a case of successful TAVR for bicuspid aortic stenosis with a severely calcified raphe. We used an undersized SAPIEN 3 valve, with three safety measures based on assessment of structural characteristics, sizing by the circle method, and deployment of the valve by the pressure-regulated method.
Collapse
Affiliation(s)
- Akihiro Tobe
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
| | - Akihito Tanaka
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Yoshiyuki Tokuda
- Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Yoshinori Shirai
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Tatsuya Miyazaki
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Satoshi Yuhara
- Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Sho Akita
- Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Kenji Furusawa
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Hideki Ishii
- Department of Cardiology, Gunma University Graduate School of Medicine, Maebashi, Japan
| | - Masato Mutsuga
- Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Toyoaki Murohara
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| |
Collapse
|
7
|
Dowling C, Gooley R, McCormick L, Sharma RP, Yeung AC, Fearon WF, Dargan J, Khan F, Firoozi S, Brecker SJ. Ongoing experience with patient-specific computer simulation of transcatheter aortic valve replacement in bicuspid aortic valve. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2023; 51:31-37. [PMID: 36740551 DOI: 10.1016/j.carrev.2023.01.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/23/2022] [Accepted: 01/18/2023] [Indexed: 01/26/2023]
Abstract
BACKGROUND Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat younger, lower-risk patients with bicuspid aortic valve (BAV). Patient-specific computer simulation may identify patients at risk for developing paravalvular regurgitation (PVR) and major conduction disturbance. Only limited prospective experience of this technology exist. We wished to describe our ongoing experience with patient-specific computer simulation. METHODS Patients who were referred for consideration of TAVR with a self-expanding transcatheter heart valve (THV) and had BAV identified on pre-procedural cardiac computed tomography imaging underwent patient-specific computer simulation. The computer simulations were reviewed by the Heart Team and used to guide surgical or transcatheter treatment approaches and to aid in THV sizing and positioning. Clinical outcomes were recorded. RESULTS Between May 2019 and May 2021, 16 patients with BAV were referred for consideration of TAVR with a self-expanding THV. Sievers Type 1 morphology was present in 15 patients and Type 0 in the remaining patient. Two patients were predicted to develop moderate-to-severe PVR with a TAVR procedure and these patients underwent successful surgical aortic valve replacement. In the remaining 14 patients, computer simulation was used to optimize THV sizing and positioning to minimise PVR and conduction disturbance. One patient with a low valve implantation depth developed moderate PVR and this complication was correctly predicted by the computer simulations. No patient required insertion of a new permanent pacemaker. CONCLUSION Patient-specific computer simulation may be used to guide the most appropriate treatment modality for patients with BAV. The usage of computer simulation to guide THV sizing and positioning was associated with favourable clinical outcomes.
Collapse
Affiliation(s)
- Cameron Dowling
- Division of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, CA, USA; MonashHeart, Monash Health and Monash Cardiovascular Research Centre, Monash University, Melbourne, Australia.
| | - Robert Gooley
- MonashHeart, Monash Health and Monash Cardiovascular Research Centre, Monash University, Melbourne, Australia
| | - Liam McCormick
- MonashHeart, Monash Health and Monash Cardiovascular Research Centre, Monash University, Melbourne, Australia
| | - Rahul P Sharma
- Division of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, CA, USA
| | - Alan C Yeung
- Division of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, CA, USA
| | - William F Fearon
- Division of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, CA, USA
| | - James Dargan
- Cardiology Clinical Academic Group, St. George's University of London and St. George's University Hospitals NHS Foundation Trust, London, United Kingdom
| | - Faisal Khan
- Cardiology Clinical Academic Group, St. George's University of London and St. George's University Hospitals NHS Foundation Trust, London, United Kingdom
| | - Sami Firoozi
- Cardiology Clinical Academic Group, St. George's University of London and St. George's University Hospitals NHS Foundation Trust, London, United Kingdom
| | - Stephen J Brecker
- Cardiology Clinical Academic Group, St. George's University of London and St. George's University Hospitals NHS Foundation Trust, London, United Kingdom
| |
Collapse
|
8
|
Xiong TY, Ali WB, Feng Y, Hayashida K, Jilaihawi H, Latib A, Lee MKY, Leon MB, Makkar RR, Modine T, Naber C, Peng Y, Piazza N, Reardon MJ, Redwood S, Seth A, Sondergaard L, Tay E, Tchetche D, Yin WH, Chen M, Prendergast B, Mylotte D. Transcatheter aortic valve implantation in patients with bicuspid valve morphology: a roadmap towards standardization. Nat Rev Cardiol 2023; 20:52-67. [PMID: 35726019 DOI: 10.1038/s41569-022-00734-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/26/2022] [Indexed: 02/08/2023]
Abstract
Indications for transcatheter aortic valve implantation (TAVI) have expanded in many countries to include patients with aortic stenosis who are at low surgical risk, and a similar expansion to this cohort is anticipated elsewhere in the world, together with an increase in the proportion of patients with bicuspid aortic valve (BAV) morphology as the age of the patients being treated decreases. To date, patients with BAV have been excluded from major randomized trials of TAVI owing to anatomical considerations. As a consequence, BAV has been a relative contraindication to the use of TAVI in international guidelines. Although clinical experience and observational data are accumulating, BAV presents numerous anatomical challenges for successful TAVI, despite advances in device design. Furthermore, in those with BAV, substantial geographical variation exists in patient characteristics, clinical approach and procedural strategy. Therefore, in this Roadmap article, we summarize the existing evidence and provide consensus recommendations from an international group of experts on the application of TAVI in patients with BAV in advance of the anticipated growth in the use of this procedure in this challenging cohort of patients.
Collapse
Affiliation(s)
- Tian-Yuan Xiong
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | | | - Yuan Feng
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Kentaro Hayashida
- Department of Cardiology, Keio University School of Medicine, Tokyo, Japan
| | | | - Azeem Latib
- Division of Cardiology, Montefiore Medical Center, New York, NY, USA
| | | | - Martin B Leon
- Columbia University Medical Center, New York, NY, USA
| | - Raj R Makkar
- Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Thomas Modine
- Department of Heart Valve Therapy, CHU Bordeaux, Bordeaux, France.,IHU Lyric, Bordeaux-, Pessac, France.,Shanghai Jiaotong University, Shanghai, China
| | - Christoph Naber
- Department of Cardiology, Klinikum Wilhelmshaven, Wilhelmshaven, Germany
| | - Yong Peng
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Nicolo Piazza
- Division of Cardiology, Department of Medicine, McGill University Health Center, Montreal, Quebec, Canada
| | - Michael J Reardon
- Houston Methodist DeBakey Heart and Vascular Center, The Methodist Hospital, Houston, TX, USA
| | - Simon Redwood
- Department of Cardiology, St Thomas' Hospital, London, UK
| | - Ashok Seth
- Fortis Escorts Heart Institute, New Delhi, India
| | - Lars Sondergaard
- The Heart Center, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| | - Edgar Tay
- National University Heart Center, National University of Singapore, Singapore, Singapore
| | - Didier Tchetche
- Department of Cardiology, Clinique Pasteur, Toulouse, France
| | - Wei-Hsian Yin
- Heart Center, ChengHsin General Hospital, Taipei, China
| | - Mao Chen
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China.
| | - Bernard Prendergast
- Department of Cardiology, St Thomas' Hospital, London, UK. .,Cleveland Clinic London, London, UK.
| | - Darren Mylotte
- Department of Cardiology, University Hospital Galway, National University of Ireland, Galway, Ireland.
| |
Collapse
|
9
|
Tchétché D, De Biase C. Implementation of the Cusp-Overlap Technique for TAVR With Balloon-Expandable Devices: Another Step Toward Standardization. JACC Cardiovasc Interv 2022; 15:2396-2397. [PMID: 36402717 DOI: 10.1016/j.jcin.2022.10.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Accepted: 10/23/2022] [Indexed: 11/18/2022]
Affiliation(s)
- Didier Tchétché
- Groupe CardioVasculaire Interventionnel, Clinique Pasteur, Toulouse, France.
| | - Chiara De Biase
- Groupe CardioVasculaire Interventionnel, Clinique Pasteur, Toulouse, France
| |
Collapse
|
10
|
Blackman DJ, Ali N, Borger MA. TAVI in younger patients with bicuspid aortic stenosis: pros and cons. EUROINTERVENTION 2022; 18:790-792. [PMID: 36412140 PMCID: PMC9725078 DOI: 10.4244/eij-e-22-00042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
| | - Noman Ali
- Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Michael A Borger
- University Clinic of Cardiac Surgery, Leipzig Heart Center, Leipzig, Germany
| |
Collapse
|
11
|
Lee YT, Yin WH, Tsao TP, Lee KC, Hsiung MC, Tzeng YH, Wei J. The Presence of Calcified Raphe Is an Independent Predictor of Adverse Long-Term Clinical Outcomes in Patients With Bicuspid Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement. Front Cardiovasc Med 2022; 9:767906. [PMID: 35497985 PMCID: PMC9043529 DOI: 10.3389/fcvm.2022.767906] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 03/10/2022] [Indexed: 12/03/2022] Open
Abstract
Objective Current guidelines recommend that transcatheter aortic valve replacement (TAVR) for bicuspid aortic valve (BAV) with aortic stenosis (AS) should only be performed in selected patients. However, we consider it even more crucial to identify what the really important factors are while determining long-term outcomes in patients with BAV undergoing TAVR, which is precisely the aim of this study. Methods We retrospectively evaluated consecutive patients who underwent TAVR with balloon-expandable Sapien XT or Sapien 3 valves (Edwards Lifesciences, Irvine, CA) for the treatment of severe bicuspid AS. The primary end points were major adverse cardiac and cerebral events (MACCE), that is, mortality, non-fatal myocardial infarction (MI), disabling stroke, valve failure needing reintervention, or clinically relevant valve thrombosis during follow-up. Results A total of 56 patients who underwent TAVR with Sapien XT (n = 20) or Sapien 3 (n = 36) were included. The device and procedural success rates were similar between the two TAVR valves; however, the newer-generation Sapien 3 yielded a trend toward better long-term clinical outcomes than the early-generation Sapien XT did (MACCE rates 35 vs. 11%, p = 0.071). In the multivariate Cox proportional hazards analyses, the presence of calcified raphe > 4 mm was the only independent predictor of long-term MACCE (hazard ratio: 6.76; 95% confidence interval: 1.21–37.67, p = 0.029). Conclusion TAVR performed by a skilled heart team, while using newer-generation balloon-expandable Sapien 3 valve, may yield better long-term clinical outcomes compared to TAVR using early-generation Sapien XT valve. Moreover, the presence of calcified raphe >4 mm is an independent determinant of adverse clinical outcomes.
Collapse
Affiliation(s)
- Yung-Tsai Lee
- Heart Center, Cheng Hsin General Hospital, Taipei, Taiwan
- Institute of Microbiology and Immunology, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Wei-Hsian Yin
- Heart Center, Cheng Hsin General Hospital, Taipei, Taiwan
- Faculty of Medicine, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- *Correspondence: Wei-Hsian Yin
| | - Tien-Ping Tsao
- Heart Center, Cheng Hsin General Hospital, Taipei, Taiwan
- Faculty of Medicine, National Defense Medical Center, Taipei, Taiwan
| | - Kuo-Chen Lee
- Heart Center, Cheng Hsin General Hospital, Taipei, Taiwan
- Faculty of Medicine, National Defense Medical Center, Taipei, Taiwan
| | | | - Yun-Hsuan Tzeng
- Faculty of Medicine, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Division of Medical Imaging, Health Management Center, Cheng Hsin General Hospital, Taipei, Taiwan
| | - Jeng Wei
- Heart Center, Cheng Hsin General Hospital, Taipei, Taiwan
- Faculty of Medicine, National Defense Medical Center, Taipei, Taiwan
| |
Collapse
|
12
|
Dowling C, Gooley R, McCormick L, Brecker SJ, Firoozi S, Bapat VN, Kodali SK, Khalique OK, Brouwer J, Swaans MJ. Patient-Specific Computer Simulation to Optimize Transcatheter Heart Valve Sizing and Positioning in Bicuspid Aortic Valve. STRUCTURAL HEART 2021. [DOI: 10.1080/24748706.2021.1991604] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|