1
|
Morales-Fernandez L, Garcia-Bardera J, Pérez-García P, Saenz-Frances F, Garcia-Saenz S, Martinez-de-la-Casa JM, Garcia-Feijoo J. Trends in glaucoma surgery in a tertiary hospital in Spain: 2010-2022. Eur J Ophthalmol 2024:11206721241295291. [PMID: 39469921 DOI: 10.1177/11206721241295291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/30/2024]
Abstract
OBJECTIVE This study aims to conduct an analysis glaucoma surgeries performed over a 13-year period at a tertiary hospital affiliated with the Spanish National Health System, with the goal of assessing temporal trends. METHODS This retrospective observational study scrutinized surgeries undertaken in the glaucoma unit of a tertiary center in Spain between 2010 and 2022. Data collected included surgical dates, procedure performed, whether it was standalone or combined, as well as patient demographics including age, sex, and type of underlying glaucoma. Surgeries on individuals under 18 years of age were excluded. An annual comparative analysis was performed to ascertain the evolving trends in glaucoma surgical interventions. RESULTS A total of 12,944 surgeries were included in the analysis, comprising 9428 isolated cataract surgeries and 2975 glaucoma procedures. Trabeculectomy, glaucoma drainage devices (GDD), and cyclodestruction, collectively referred to as traditional surgery, demonstrated a decline from 93.2% to 23.6% over the study duration. Minimally invasive glaucoma surgery (MIGS) and minimally invasive bleb surgery (MIBS) demonstrated a significant increase from 3.8% in 2010 to 74.7% in 2022, relative to the total glaucoma surgeries. Furthermore, combined surgeries manifested a noteworthy increase from 39.0% in 2010 to 44.2% in 2022, with 86.4% of combined procedures in 2022 being MIGS or MIBS. CONCLUSION In recent years, there has been a noticeable change in the trend of glaucoma surgeries, with MIGS and MIBS procedures experiencing a significant increase and becoming the most commonly performed glaucoma procedures. Consequently, traditional glaucoma surgeries have decreased in frequency.
Collapse
Affiliation(s)
- Laura Morales-Fernandez
- Ophthalmology Unit, Hospital Clinico San Carlos, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
- Hospital Universitario Quironsalud Madrid, Madrid, Spain
| | - Javier Garcia-Bardera
- Ophthalmology Unit, Hospital Clinico San Carlos, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
| | - Pilar Pérez-García
- Ophthalmology Unit, Hospital Clinico San Carlos, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
| | - Federico Saenz-Frances
- Ophthalmology Unit, Hospital Clinico San Carlos, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
| | - Sofia Garcia-Saenz
- Ophthalmology Unit, Hospital Clinico San Carlos, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
| | - Jose M Martinez-de-la-Casa
- Ophthalmology Unit, Hospital Clinico San Carlos, Dept. of Ophthalmology and ORL, Faculty of Medicine, Universidad Complutense de Madrid, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
- Instituto de Investigaciones Oftalmologicas Ramon Castroviejo, Universidad Complutense de Madrid, Madrid, Spain
| | - Julian Garcia-Feijoo
- Ophthalmology Unit, Hospital Clinico San Carlos, Dept. of Ophthalmology and ORL, Faculty of Medicine, Universidad Complutense de Madrid, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
- Instituto de Investigaciones Oftalmologicas Ramon Castroviejo, Universidad Complutense de Madrid, Madrid, Spain
| |
Collapse
|
2
|
Morales-Fernández L, Pérez-García P, Martínez-de-la-Casa JM, Sáenz-Francés F, Pascual-Santiago MA, Ginés-Gallego C, García-Feijoo J. Intraoperative OCT to check the correct postimplant position of Preserflo TM. Eur J Ophthalmol 2024:11206721241272169. [PMID: 39105405 DOI: 10.1177/11206721241272169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/07/2024]
Abstract
INTRODUCTION This study was designed to examine the capacity of intraoperative optical coherence tomography (OCT) to predict the postimplant position of the glaucoma drainage device PreserfloTM. METHODS 13 eyes (mean age 65.42 (14.89) years) underwent PreserfloTM (Santen, Osaka, Japan) placement. Before surgery, participants were subjected to a comprehensive ophthalmic examination (intraocular pressure (IOP), cup to disk ratio (C/D), visual field, OCT, endothelial cell count). Anterior segment OCT scans were obtained intraoperatively using a Rescan 700 OCT system (Carl Zeiss Meditec, Inc., Oberkochen, Germany). One day postsurgery, anterior segment OCT using the Spectralis OCT (Heidelberg Engineering GmbH) was performed in a sitting position to capture the same chamber cross-section as before. The main outcome variables were tube-endothelium distance (T-E) and tube length (TL) in the anterior chamber measured using both OCT systems. Correlation between intraoperative and office measurements was examined through Pearson correlation (r) and intraclass correlation coefficients (ICC). RESULTS Mean intraoperative and in-office T-E were 625.26 (SD 366.60) versus 561.16 (SD 364.62) µm respectively (p = 0.540). Intraoperative and in-office anterior chamber TL were 1386 (SD 701.82) and 1433.91 (SD 713.55) µm, respectively (p = 0.029). Excellent correlation was observed between both sets of T-E (r = 0.992; p = 0.008) and TL (r = 0.984; p = 0.016) values. Both OCT systems showed good agreement yielding ICCs of 0.992 (p < 0.001) for T-E and 0.995 (p = 0.001) for TL. DISCUSSION Excellent correlation was observed between our intraoperative and postoperative OCT measurements. These results support the usefulness of intraoperative OCT to confirm the correct position of an implanted PreserfloTM microshunt.
Collapse
Affiliation(s)
- Laura Morales-Fernández
- Ophthalmology Unit, Hospital Clinico San Carlos, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
- Ophthalmology Unit, Hospital Universitario Quironsalud Madrid, Madrid, Spain
| | - Pilar Pérez-García
- Ophthalmology Unit, Hospital Clinico San Carlos, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
| | - José María Martínez-de-la-Casa
- Ophthalmology Unit, Hospital Clinico San Carlos, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
| | - Federico Sáenz-Francés
- Ophthalmology Unit, Hospital Clinico San Carlos, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
| | - Marco-Antonio Pascual-Santiago
- Ophthalmology Unit, Hospital Clinico San Carlos, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
| | - Cristina Ginés-Gallego
- Ophthalmology Unit, Hospital Clinico San Carlos, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
| | - Julián García-Feijoo
- Ophthalmology Unit, Hospital Clinico San Carlos, Instituto de Investigacion Sanitaria del Hospital Clinico San Carlos (IdISSC), Madrid, Spain
| |
Collapse
|
3
|
Bahlmann D, van Oterendorp C. [Glaucoma Filtration Surgery - Bleb-forming Procedures]. Klin Monbl Augenheilkd 2024; 241:863-880. [PMID: 38788734 DOI: 10.1055/a-2305-5053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2024]
Abstract
Glaucoma filtration surgery has been a standard surgical therapy for decades. An increasing knowledge about wound healing processes in the eye, the introduction of antimetabolite treatment and continuous improvements of the surgical technique helped making trabeculectomy - the prototype filtration surgery - a very effective therapeutic tool. However, best results will only be regularly achieved with a high level of experience and time dedicated to postoperative follow-up. Furthermore, the potential for severe early and late complications still remains high. Thus, novel stent-based filtration surgery approaches, such as the Preserflo and the XEN shunt have been introduced. This review presents these three bleb-forming filtration procedures, covering the basic principles of surgical technique, data on effectivity as well as complications.
Collapse
|
4
|
Khawaja AP, Abegão Pinto L, Stalmans I, Aptel F, Barkander A, Barton K, Beckers H, Iliev M, Klink T, Marchini G, Martínez de la Casa J, Pillunat KR, Simonsen JH, Vass C. Additional Guidance on the Use of the PRESERFLO™ MicroShunt in the Treatment of Glaucoma: Insights from a Second Delphi Consensus Panel. Ophthalmol Ther 2024; 13:1569-1588. [PMID: 38587774 PMCID: PMC11109085 DOI: 10.1007/s40123-024-00902-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 01/29/2024] [Indexed: 04/09/2024] Open
Abstract
INTRODUCTION The PRESERFLO™ MicroShunt (PMS) has been proven to significantly lower intraocular pressure (IOP) in patients with glaucoma and has been available for use since 2019. With increasing published evidence and growing experience of glaucoma surgeons, the aim of this modified Delphi panel was to build on the findings of a previous Delphi panel conducted in 2021 and provide further guidance on the role of the PMS to treat patients with glaucoma in Europe. METHODS Thirteen European glaucoma surgeons experienced in the PMS procedure participated in a 3-round modified Delphi panel. A targeted literature review and expert steering committee guided Round 1 questionnaire development. Consensus was pre-defined at a threshold of ≥ 70% of panellists selecting 'strongly agree'/'agree' or 'strongly disagree'/'disagree' for 6-point Likert scale questions or ≥ 70% selecting the same option for multiple or single-choice questions. Questions not reaching consensus were restated/revised for the next round, following guidance from free-text responses/scoping questions. RESULTS In total, 28% (n = 9/32), 52% (n = 16/31) and 91% (n = 10/11) of statements reached consensus in Rounds 1, 2 and 3, respectively. There was agreement that the PMS may be used in patients with pigmentary, post-trauma or post-vitrectomy glaucoma and for patients with uveitic glaucoma without active inflammation. The PMS may be more suitable for patients with contact lenses than other subconjunctival filtering surgeries, without eliminating bleb-associated risks. Consensus was reached that combining PMS implantation and phacoemulsification may be as safe as standalone PMS surgery, but further efficacy data are required. Following a late rise in IOP ≥ 4 months post-surgery, topical aqueous suppressant drops or bleb revision may be suitable management options. CONCLUSIONS This Delphi panel builds on the considerations explored in the 2021 Delphi panel and provides further detailed guidance for glaucoma surgeons on the use of the PMS, reflecting the availability of novel evidence and surgical experience. Videos are available for this article.
Collapse
Affiliation(s)
- Anthony P Khawaja
- NIHR Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK.
| | | | - Ingeborg Stalmans
- Department of Ophthalmology, University Hospitals UZ Leuven, Leuven, Belgium
- Research Group Ophthalmology, Catholic University KU Leuven, Leuven, Belgium
| | - Florent Aptel
- Clinique Universitaire d'Ophtalmologie, CHU de Grenoble-Alpes, Grenoble, France
| | - Anna Barkander
- Department of Ophthalmology, Östersund Hospital, Östersund, Sweden
| | - Keith Barton
- NIHR Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK
| | - Henny Beckers
- University Eye Clinic, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - Milko Iliev
- Ophthalmology Department, University of Bern, Inselspital, Bern, Switzerland
| | - Thomas Klink
- Herzog Carl-Theodor Eye Hospital, Munich, Germany
| | - Giorgio Marchini
- Department of Neurosciences, Biomedicine and Movement, Eye Clinic and UOC Oculistica, University Hospital and AOUI, Verona, Italy
| | | | - Karin R Pillunat
- Department of Ophthalmology, Medical Faculty Carl Gustav Carus, Technical University, Dresden, Germany
| | - Jan H Simonsen
- Department of Ophthalmology, Aalborg University Hospital, Aalborg, Denmark
| | - Clemens Vass
- Department of Ophthalmology and Optometry, Medical University Vienna, Vienna, Austria
| |
Collapse
|
5
|
Gassel CJ, Wenzel DA, Nasyrov E, Strasser T, Voykov B. Intermediate-term impact on corneal endothelial cells and efficacy of Preserflo MicroShunt implantation in patients with open-angle glaucoma - a prospective study over two years. Graefes Arch Clin Exp Ophthalmol 2024:10.1007/s00417-024-06508-8. [PMID: 38771337 DOI: 10.1007/s00417-024-06508-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 05/03/2024] [Accepted: 05/06/2024] [Indexed: 05/22/2024] Open
Abstract
INTRODUCTION Preserflo MicroShunt is a novel microinvasive bleb forming device for the treatment of primary open-angle glaucoma. The intermediate- and long-term success and the impact of this procedure on corneal endothelial cell density remain to be investigated. METHODS In this prospective observational study, 62 eyes of 55 glaucoma patients (mean age ± SD: 67.0 ± 15.0 years) receiving a Preserflo MicroShunt were included. Corneal endothelial cell density, intraocular pressure and best corrected visual acuity were assessed preoperatively and at 3, 6, 9, 12, 18 and 24 months postoperatively. Success rates, bleb revision rates and complications were analysed. Complete success was defined as an intraocular pressure reduction of ≥ 20% and achieving a target pressure of ≤ 18, ≤ 15 or ≤ 12 mmHg without antiglaucoma medication. Qualified success indicated that the criteria were reached with or without medication. RESULTS Corneal endothelial cells showed no significant decline over 24 months (p > 0.05). Intraocular pressure showed a substantial reduction postoperatively (p < 0.001), decreasing from 29.6 ± 8,3 mmHg to 13.0 ± 4.3 mmHg after 24 months (p < 0.001). Complete and qualified success with a target pressure ≤ 15 mmHg was achieved in 52.9% and 54.6% of cases after 24 months, respectively. Best corrected visual acuity did not change after 24 months. CONCLUSION Preserflo MicroShunt had no negative side effects on corneal endothelial cells and showed favourable success rates after 2 years in patients with open-angle glaucoma.
Collapse
Affiliation(s)
- Caroline J Gassel
- University Eye Hospital Tuebingen, Centre for Ophthalmology, Elfriede-Aulhorn-Str. 7, Tübingen, 72076, Germany.
| | - Daniel A Wenzel
- University Eye Hospital Tuebingen, Centre for Ophthalmology, Elfriede-Aulhorn-Str. 7, Tübingen, 72076, Germany
| | - Emil Nasyrov
- University Eye Hospital Tuebingen, Centre for Ophthalmology, Elfriede-Aulhorn-Str. 7, Tübingen, 72076, Germany
| | - Torsten Strasser
- University Eye Hospital Tuebingen, Centre for Ophthalmology, Elfriede-Aulhorn-Str. 7, Tübingen, 72076, Germany
- Institute for Ophthalmic Research, Centre for Ophthalmology, Tuebingen, Germany
| | - Bogomil Voykov
- University Eye Hospital Tuebingen, Centre for Ophthalmology, Elfriede-Aulhorn-Str. 7, Tübingen, 72076, Germany
| |
Collapse
|
6
|
Gläser T, Böhringer D, Evers C, Keye P, Reinhard T, Lübke J. Clinical Results of the MINIject Implant for Suprachoroidal Drainage. J Clin Med 2024; 13:2831. [PMID: 38792373 PMCID: PMC11122232 DOI: 10.3390/jcm13102831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Revised: 05/07/2024] [Accepted: 05/08/2024] [Indexed: 05/26/2024] Open
Abstract
Objective: This retrospective study evaluated the safety and efficacy of the new minimally invasive MINIject implant placed in the suprachoroidal space. The aim was to assess its impact on intraocular pressure (IOP) reduction and complication rate. Methods: 18 eyes from 18 patients with insufficiently controlled glaucoma received the implant using topical medications. Outcomes were changes in IOP, change in IOP medication, need for other glaucoma surgery, and rate of adverse events. Results: IOP reduced by 15% (p < 0.05) following MINIject implantation. IOP medication decreased from 3 to 1 agent (p < 0.05). Four patients (22%) required other glaucoma surgery while we did not observe any clinically relevant adverse event. Conclusions: This retrospective study indicates that MINIject implants may be a safe and effective means of reducing IOP together with a reduction in IOP medications in most patients. Larger prospective studies with longer follow-ups are necessary to confirm our results, though.
Collapse
Affiliation(s)
- Timothy Gläser
- Eye Center, University Hospital Freiburg, 79106 Freiburg im Breisgau, Germany (T.R.); (J.L.)
| | | | | | | | | | | |
Collapse
|
7
|
Ahmed IIK, Sheybani A, De Francesco T, Samuelson TW. Corneal endothelial safety profile in minimally invasive glaucoma surgery. J Cataract Refract Surg 2024; 50:369-377. [PMID: 37988037 PMCID: PMC10959532 DOI: 10.1097/j.jcrs.0000000000001365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 10/08/2023] [Accepted: 11/02/2023] [Indexed: 11/22/2023]
Abstract
PURPOSE To compare 5-year corneal endothelial safety of 3 minimally invasive glaucoma surgery (MIGS) devices (iStent inject , Hydrus Microstent, CyPass Micro-Stent). SETTING U.S. multicenter trials. DESIGN Post hoc 5-year analysis from prospective randomized single-masked pivotal trials. METHODS Mild to moderate open-angle glaucoma subjects received a MIGS implant with phacoemulsification (implant + phaco) or phaco alone (control). In addition, 5-year end points comparing the implant and control groups included proportion of eyes with significant endothelial cell loss (ECL) (>30% or ≥30% vs baseline) and mean endothelial cell density (ECD). RESULTS Comparable proportions of eyes in the iStent inject + phaco and control groups had significant 60-month ECL (9.4% vs 6.3%, respectively, diff: 3.2%, 95% CI, -5.0% to 11.3%, P = .77). Hydrus (20.8% vs 10.6%, diff: 10.2%, 95% CI, 3.2% to 17.2%, P = .01) and CyPass (27.2% vs 10.0%, diff: 17.2%, 95% CI, 5.6% to 28.7%, P = .02) had more eyes with ECL vs controls (iStent inject 1.49X, Hydrus 1.96X, CyPass 2.72X vs controls). Mean ECD over 60 months for iStent inject was indistinguishable vs control, whereas greater ECL was observed primarily 3 months postoperative (Hydrus) or accelerated after 2 years (CyPass). No iStent inject or Hydrus subjects developed persistent corneal edema, whereas 7 CyPass-implanted eyes developed ECL-related complications. CONCLUSIONS Through 5 years postoperative, there were no differences in proportion of eyes with significant ECL or mean ECD between the iStent inject and control groups. There was greater 5-year ECL and lower ECD in the Hydrus and CyPass groups vs controls. The Hydrus ECL rate mirrored control after 3 months; the CyPass ECL rate accelerated vs control.
Collapse
Affiliation(s)
- Iqbal Ike K. Ahmed
- From the John A. Moran Eye Center, University of Utah, Salt Lake City, Utah (Ahmed, Sheybani, De Francesco); Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada (Ahmed); Department of Ophthalmology and Visual Sciences, Washington University in St. Louis School of Medicine, St. Louis, Missouri (Sheybani); Clinica de Olhos de Francesco, Fortaleza, Brazil (De Francesco); Hospital de Olhos Leiria de Andrade (HOLA), Fortaleza, Brazil (De Francesco); Minnesota Eye Consultants, University of Minnesota, Minneapolis, Minnesota (Samuelson)
| | - Arsham Sheybani
- From the John A. Moran Eye Center, University of Utah, Salt Lake City, Utah (Ahmed, Sheybani, De Francesco); Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada (Ahmed); Department of Ophthalmology and Visual Sciences, Washington University in St. Louis School of Medicine, St. Louis, Missouri (Sheybani); Clinica de Olhos de Francesco, Fortaleza, Brazil (De Francesco); Hospital de Olhos Leiria de Andrade (HOLA), Fortaleza, Brazil (De Francesco); Minnesota Eye Consultants, University of Minnesota, Minneapolis, Minnesota (Samuelson)
| | - Ticiana De Francesco
- From the John A. Moran Eye Center, University of Utah, Salt Lake City, Utah (Ahmed, Sheybani, De Francesco); Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada (Ahmed); Department of Ophthalmology and Visual Sciences, Washington University in St. Louis School of Medicine, St. Louis, Missouri (Sheybani); Clinica de Olhos de Francesco, Fortaleza, Brazil (De Francesco); Hospital de Olhos Leiria de Andrade (HOLA), Fortaleza, Brazil (De Francesco); Minnesota Eye Consultants, University of Minnesota, Minneapolis, Minnesota (Samuelson)
| | - Thomas W. Samuelson
- From the John A. Moran Eye Center, University of Utah, Salt Lake City, Utah (Ahmed, Sheybani, De Francesco); Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada (Ahmed); Department of Ophthalmology and Visual Sciences, Washington University in St. Louis School of Medicine, St. Louis, Missouri (Sheybani); Clinica de Olhos de Francesco, Fortaleza, Brazil (De Francesco); Hospital de Olhos Leiria de Andrade (HOLA), Fortaleza, Brazil (De Francesco); Minnesota Eye Consultants, University of Minnesota, Minneapolis, Minnesota (Samuelson)
| |
Collapse
|
8
|
George J, Abouzeid H. PRESERFLO MicroShunt in Severe Myopia: A Case Report and Review of the Literature. Klin Monbl Augenheilkd 2024; 241:361-366. [PMID: 38653303 DOI: 10.1055/a-2239-0636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2024]
Abstract
The PRESERFLO™ MicroShunt (MP; Santen Inc., Osaka, Japan) is a minimally invasive bleb surgery (MIBS) manufactured to treat primary open-angle glaucoma (POAG), with lower postoperative adverse effects than with conventional filtering surgeries. We describe here the case study of a 58-year-old woman who presented with bilateral severe myopia with bilateral advanced POAG and unreached target pressure under quadritherapy, who was successfully managed by PM surgery. A review of the literature completes our observation. At presentation, the patient had a spherical equivalent of - 7.50 RE and - 7.75 LE with an IOP of 22 mmHg right and left eye (RLE) under quadritherapy, and with severe bilateral visual field loss, including scotomas within the central 5°. The patient presented with systemic hypertension treated with an antihypertensive drug. Two selective laser trabeculoplasties (SLT), performed 3 months apart, were first tried on the LE, without any change in IOP at 2 months. After considering the high risk of postoperative complications, a PM operation was proposed, with a targeted IOP in the mid-fifteens RLE. The patient's eyes underwent PM surgery with mitomycin C (MMC) MMC0.2 mg/mL for 3 minutes without any complications. The LE required 2 consecutive needlings with 1 mL MMC0.2 mg/mL. At 24 months after surgery, the two eyes gave successful results without the need for any additional medical therapy, and with well-functioning conjunctival blebs. The PM was an effective alternative to the gold standard trabeculectomy in our severely myopic patient. A comparative study between conventional filtering operations and this MIBS in highly myopic patients would confirm our observation.
Collapse
Affiliation(s)
- Jérôme George
- Ophthalmology, University of Geneva, Faculty of Medicine, Geneva, Switzerland
| | - Hana Abouzeid
- Ophthalmology, University of Geneva, Faculty of Medicine, Geneva, Switzerland
| |
Collapse
|
9
|
Rojo-Arnao M, Martinez-de-la-Casa JM, Albis-Donado O, Yañez-Castro G, Maroto-Cejudo R, Téllez J, Menoyo-Calatayud R. Preserflo TM MicroShunt implantation combined with Ologen TM in primary and secondary glaucoma patients in a clinical setting. Indian J Ophthalmol 2024; 72:417-426. [PMID: 38153975 PMCID: PMC11001232 DOI: 10.4103/ijo.ijo_1502_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 09/24/2023] [Accepted: 10/18/2023] [Indexed: 12/30/2023] Open
Abstract
PURPOSE This study aims to assess the effectiveness and safety of combining the Preserflo™ MicroShunt implant (MicroShunt) with a simultaneous Ologen™ implant in patients with glaucoma. METHODS We conducted a retrospective study on consecutive patients with medically uncontrolled glaucoma who underwent MicroShunt + Ologen implantation as a standalone procedure or in combination with phacoemulsification (combined procedure). Success was defined as achieving an intraocular pressure (IOP) of 6-15 mmHg at 18 months post surgery, with a preoperative IOP reduction of at least 20%, and without (complete success) or with (qualified success) the need for antiglaucoma medications. The primary endpoint was the success rate. RESULTS Forty-eight eyes from 47 patients were included, with 28 eyes (58.3%) undergoing the standalone procedure and 20 eyes (41.7%) undergoing the combined procedure. Overall, there was a significant reduction in preoperative IOP from 19.7 ± 5.8 mmHg to 11.4 ± 2.6 mmHg at 18 months ( P < 0.0001). In the standalone procedure group, preoperative IOP decreased from 21.5 ± 5.2 mmHg to 11.7 ± 2.5 mmHg ( P < 0.0001), and in the combined procedure group, preoperative IOP decreased from 17.1 ± 5.8 mmHg to 10.9 ± 2.7 mmHg ( P = 0.0002), with no significant difference between the two groups regarding final IOP. The mean number of antiglaucoma medications significantly decreased from 3.2 ± 1.1 to 0.3 ± 0.7 in the overall study population ( P < 0.0001). At 18 months, 40 eyes (83.3%) were classified as successful. Regarding safety, out of the total number of eyes, two (4.2%) experienced choroidal detachment without visual impairment, two (4.2%) had transient hyphema, one (2.1%) showed reactivation of a corneal herpetic ulcer, one (2.1%) had diplopia, and one (2.1%) exhibited a shallow anterior chamber during the first week. CONCLUSION The combination of Ologen™ and Preserflo™ MicroShunt, either alone or in conjunction with phacoemulsification, demonstrated a favorable profile in terms of IOP reduction and safety.
Collapse
Affiliation(s)
| | - José María Martinez-de-la-Casa
- Department of Ophthalmology and ORL, Faculty of Medicine, Ophthalmology Unit, Hospital Clinico San-Carlos, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clinico San-Carlos (IdISSC), Madrid, Spain
- Department of Immunology, Ophthalmology and ORL, School of Medicine, Instituto de Investigaciones Oftalmologicas Ramon Castroviejo, Universidad Complutense de Madrid, Madrid, Spain
| | - Oscar Albis-Donado
- Glaucoma Specialist, Private Practice, Visual Sense, Mexico City, Mexico
| | | | | | - Jesús Téllez
- Department of Ophthalmology, Hospital de la Santa Creu i de Sant Pau, Autonoma University of Barcelona, Barcelona, Spain
- Departament of Ophthalmology, Grupo Admiravisión, Barcelona, Spain
| | | |
Collapse
|
10
|
Anton Steindor F, Trigaux C, Holtmann C, Spaniol K, Geerling G, Borrelli M. Preserflo MicroShunt: Efficacy and Endothelial Cell Density. J Glaucoma 2023; 32:1018-1021. [PMID: 38200660 DOI: 10.1097/ijg.0000000000002325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Accepted: 09/08/2023] [Indexed: 01/12/2024]
Abstract
PRCIS A main safety concern associated with new glaucoma implants is corneal endothelial cell loss, which could even be observed in already established procedures. PURPOSE The purpose of this study was to evaluate the efficacy and corneal safety, especially corneal endothelial cell loss (ECL), after Preserflo MicroShunt implantation. METHODS A monocentric, prospective clinical observational study of patients with a follow-up of at least 12 months who underwent Preserflo MicroShunt implantation at the Department of Ophthalmology, University Hospital of Düsseldorf, Germany, between January 2020 and October 2021. Endothelial cell density (ECD), the distance between the tip of the implant and the corneal endothelium, and the success of the surgery were analyzed. RESULTS In total, 14 eyes of 12 patients were included. After a mean follow-up of 20±2.7 months intraocular pressure was significantly reduced by 8.2 mm Hg (P=0.0041); in 28.6% of patients, a revision surgery was necessary. Reduction of preoperative and follow-up ECD was not statistically significant (ECL of 45 cells/mm2, ECDpreoperative=2074±703.6 cells/mm2, ECDlast follow-up=2029±742.3 cells/mm2, P=0.42). A longer intracameral shunt tube length correlated significantly with a higher distance between the shunt tip and corneal endothelium (r=0.61, P=0.036). CONCLUSIONS Preserflo MicroShunt effectively lowered intraocular pressure without substantial ECL after a minimum follow-up period of 17 months.
Collapse
|
11
|
Chan PPM, Larson MD, Dickerson JE, Mercieca K, Koh VTC, Lim R, Leung EHY, Samuelson TW, Larsen CL, Harvey A, Töteberg-Harms M, Meier-Gibbons F, Shu-Wen Chan N, Sy JB, Mansouri K, Zhang X, Lam DSC. Minimally Invasive Glaucoma Surgery: Latest Developments and Future Challenges. Asia Pac J Ophthalmol (Phila) 2023; 12:537-564. [PMID: 38079242 DOI: 10.1097/apo.0000000000000646] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 10/12/2023] [Indexed: 12/21/2023] Open
Abstract
The development of minimally invasive glaucoma surgeries (MIGSs) was intended to provide safe and modestly efficacious modalities for early intervention of mild-to-moderate glaucoma, with minimal trauma and rapid recovery. They were mainly ab interno procedures that reduce intraocular pressure by facilitating the aqueous outflow by bypassing the trabecular meshwork resistance, reinforcing the uveoscleral flow via the supraciliary space, and reducing aqueous production by the ciliary body. While the cumulating evidence helps shape the role of the available MIGS, the exponential new development and advancement in this field has expanded the territory of MIGS. Apart from developing subconjunctival MIGS filtration devices (Xen gel stent and PRESERFLO MicroShunt), there is a tendency to revisit the "traditional" MIGS for alternative use and to modify the procedures with consideration of the fundamental aqueous outflow physiology. Combined MIGS has also been suggested, based on the theory that their different mechanisms may provide additive or synergistic effects. The advancement of laser procedures is also promising and could supplement unmet needs along the glaucoma treatment algorithm. This review examines the broad array of MIGS, updates the recent findings, discusses their potential alternative applications, and explores future challenges.
Collapse
Affiliation(s)
- Poemen P M Chan
- Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, China
- Department of Ophthalmology and Visual Sciences, Lam Kin Chung. Jet King-Shing Ho Glaucoma Treatment and Research Centre, The Chinese University of Hong Kong, Hong Kong, China
| | | | - Jaime E Dickerson
- Sight Sciences, Menlo Park, CA, USA
- University of North Texas Health Science Center, North Texas Eye Research Institute, Fort Worth, TX, USA
| | | | - Victor Teck Chang Koh
- Department of Ophthalmology, National University Health System, Singapore
- Centre for Innovation and Precision Eye Health, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Ridia Lim
- Department of Ophthalmology, Sydney Eye Hospital, Sydney, Australia
- Save Sight Institute, Sydney Medical School, The University of Sydney, Sydney, Australia
| | - Enne Hiu Ying Leung
- The C-MER Dennis Lam & Partners Eye Center, C-MER International Eye Care Group, Hong Kong, China
| | - Thomas W Samuelson
- Minnesota Eye Consultants, Bloomington, MN, US
- Department of Ophthalmology, University of Minnesota, MN, US
| | - Christine L Larsen
- Minnesota Eye Consultants, Bloomington, MN, US
- Department of Ophthalmology, University of Minnesota, MN, US
| | | | - Marc Töteberg-Harms
- Department of Ophthalmology, Augusta University, Medical College of Georgia, Augusta, GA, USA
| | | | | | - Jessica Belle Sy
- Department of Ophthalmology, Sydney Eye Hospital, Sydney, Australia
- Baguio General Hospital and Medical Center, Baguil City, Benguet, Philippines
| | - Kaweh Mansouri
- Glaucoma Center, Swiss Visio, Clinique de Montchoisi, Lausanne, Switzerland
| | - Xiulan Zhang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Dennis S C Lam
- The C-MER Dennis Lam & Partners Eye Center, C-MER International Eye Care Group, Hong Kong, China
- The International Eye Research Institute of The Chinese University of Hong Kong (Shenzhen), Shenzhen, China
| |
Collapse
|
12
|
Ang BCH, Lim SY, Betzler BK, Wong HJ, Stewart MW, Dorairaj S. Recent Advancements in Glaucoma Surgery-A Review. Bioengineering (Basel) 2023; 10:1096. [PMID: 37760198 PMCID: PMC10525614 DOI: 10.3390/bioengineering10091096] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 09/10/2023] [Accepted: 09/11/2023] [Indexed: 09/29/2023] Open
Abstract
Surgery has long been an important treatment for limiting optic nerve damage and minimising visual loss in patients with glaucoma. Numerous improvements, modifications, and innovations in glaucoma surgery over recent decades have improved surgical safety, and have led to earlier and more frequent surgical intervention in glaucoma patients at risk of vision loss. This review summarises the latest advancements in trabeculectomy surgery, glaucoma drainage device (GDD) implantation, and minimally invasive glaucoma surgery (MIGS). A comprehensive search of MEDLINE, EMBASE, and CENTRAL databases, alongside subsequent hand searches-limited to the past 10 years for trabeculectomy and GDDs, and the past 5 years for MIGS-yielded 2283 results, 58 of which were included in the final review (8 trabeculectomy, 27 GDD, and 23 MIGS). Advancements in trabeculectomy are described in terms of adjunctive incisions, Tenon's layer management, and novel suturing techniques. Advancements in GDD implantation pertain to modifications of surgical techniques and devices, novel methods to deal with postoperative complications and surgical failure, and the invention of new GDDs. Finally, the popularity of MIGS has recently promoted modifications to current surgical techniques and the development of novel MIGS devices.
Collapse
Affiliation(s)
- Bryan Chin Hou Ang
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore 308433, Singapore
- Department of Ophthalmology, National Healthcare Group Eye Institute, Woodlands Health Campus, Singapore 737628, Singapore
| | - Sheng Yang Lim
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore 308433, Singapore
| | - Bjorn Kaijun Betzler
- Department of Surgery, Tan Tock Seng Hospital, National Healthcare Group, Singapore 308433, Singapore
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119077, Singapore
| | - Hon Jen Wong
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119077, Singapore
| | - Michael W. Stewart
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL 32224, USA; (M.W.S.)
| | - Syril Dorairaj
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL 32224, USA; (M.W.S.)
| |
Collapse
|
13
|
Tube–Iris Distance and Corneal Endothelial Cell Damage Following Ahmed Glaucoma Valve Implantation. J Clin Med 2022; 11:jcm11175057. [PMID: 36078987 PMCID: PMC9456630 DOI: 10.3390/jcm11175057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 08/19/2022] [Accepted: 08/21/2022] [Indexed: 11/16/2022] Open
Abstract
The most significant factor for endothelial cell loss should be readily identified, since prevention is the most crucial treatment. Here, we investigate risk factors for corneal endothelial cell density (ECD) decline following Ahmed glaucoma valve (AGV) implantation and determine the optimal cut-off values. This study included 103 eyes (95 patients) with glaucoma that underwent AGV implantation between January 2006 and January 2021 at a single medical center (Severance Hospital). We conducted consecutive t-tests between two groups separated by the ECD change rate to determine the survival state of the enrolled patients. Associations were evaluated using univariable and multivariable linear regressions. Optimal cut-off values for identified risk factors were analyzed using a Cox proportional hazards model and a receiver operating characteristic (ROC) curve based on logistic regression. Mean follow-up duration was 4.09 ± 2.20 years. After implementing consecutive t-tests, only patients with an ECD change rate greater than −6.1%/year were considered to have survived. Tube–iris distance (TID) was the only statistically significant factor identified in both the univariable and multivariable linear regressions. The cut-off value determined from the consecutive Cox regression method was 0.33 mm (smallest p-value of 0.0087), and the cut-off value determined from the ROC method was 0.371 mm (area under the receiver operating characteristic curve [AUC], 0.662). Patients with short TIDs showed a better ECD prognosis following AGV surgery; we suggest optimal TID cut-off values of 0.33 mm and 0.371 mm based on the implemented Cox regression and ROC methodology, respectively.
Collapse
|
14
|
Burgos-Blasco B, García-Feijóo J, Perucho-Gonzalez L, Güemes-Villahoz N, Morales-Fernandez L, Mendez-Hernández CD, Martinez de la Casa JM, Konstas AG. Evaluation of a Novel Αb Εxterno MicroShunt for the Treatment of Glaucoma. Adv Ther 2022; 39:3916-3932. [PMID: 35797002 PMCID: PMC9402735 DOI: 10.1007/s12325-022-02230-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Accepted: 06/16/2022] [Indexed: 11/29/2022]
Abstract
The surgical management of glaucoma has been revolutionized by the introduction of minimally invasive glaucoma surgery (MIGS). The various MIGS options aim to meaningfully lower intraocular pressure with a better safety profile than traditional glaucoma surgery. The key clinical attributes and the emerging potential of an ab externo MicroShunt (PreserFlo™) are reviewed in the context of published evidence and clinical experience. This novel MicroShunt consists of an 8.5-mm-long tube that is implanted in the eye via an ab externo approach enabling aqueous humor drainage into the sub-Tenon’s space through the formation of a bleb, similar in appearance to that created by trabeculectomy. The efficacy and safety of this procedure, the concomitant use of antimetabolites, the impact of tube positioning, and its future value in clinical practice are critically reviewed. Recent evidence has demonstrated the MicroShunt to be less effective than traditional filtration surgery, but with a significant improvement in safety. Cumulative data suggest that the new implant provides tangible clinical benefits to selected patients with glaucoma in need of further intraocular pressure (IOP) lowering. Future research should delineate the precise role of this and other MIGS options in the rapidly evolving glaucoma treatment algorithm.
Collapse
Affiliation(s)
| | - Julián García-Feijóo
- Servicio de Oftalmología, Hospital Clínico San Carlos; IdISSC, Madrid, Spain.,Departamento de Inmunología, Oftalmología y ORL, Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain
| | | | | | | | - Carmen D Mendez-Hernández
- Servicio de Oftalmología, Hospital Clínico San Carlos; IdISSC, Madrid, Spain.,Departamento de Inmunología, Oftalmología y ORL, Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain
| | - Jose M Martinez de la Casa
- Servicio de Oftalmología, Hospital Clínico San Carlos; IdISSC, Madrid, Spain.,Departamento de Inmunología, Oftalmología y ORL, Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain
| | - Anastasios G Konstas
- 1st and 3rd University, Departments of Ophthalmology, Aristotle University of Thessaloniki, Thessaloniki, Greece. .,Department of Ophthalmology, 1st University, AHEPA University Hospital, 1 Kyriakidi Street, 54636, Thessaloniki, Greece.
| |
Collapse
|
15
|
Efficacy and Safety of the Preserflo Microshunt With Mitomycin C for the Treatment of Open Angle Glaucoma. J Glaucoma 2022; 31:557-566. [PMID: 35583510 PMCID: PMC9232283 DOI: 10.1097/ijg.0000000000002052] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Accepted: 05/02/2022] [Indexed: 01/31/2023]
Abstract
PRCIS The Preserflo Microshunt (PSM) is a safe and effective glaucoma microfiltering implant that significantly reduces the intraocular pressure (IOP), either alone or in combination with phacoemulsification, during the first year after surgery. PURPOSE The purpose of this study was to assess the safety and efficacy of the PSM for the treatment of open angle glaucoma with 0.2 mg/mL mitomycin C, either alone or in combination with cataract surgery. METHODS A retrospective, open-label study of 64 eyes with primary open angle glaucoma that underwent PSM implantation and were followed up for at least 9 months. Success was defined as IOP 6-17 mm Hg and a reduction of at least 20%, complete without hypotensive medication, and qualified with medication. Safety was assessed by the incidence of adverse events. Secondary endpoints included mean hypotensive medications, visual acuity, and incidence of needling and surgical revision. RESULTS A total of 51 eyes underwent PSM alone and 13 underwent PSM+phacoemulsification. In the overall population of the study, the mean IOP was significantly reduced from 22.03±0.7 mm Hg at baseline to 12.7±0.4 mm Hg at the final visit, P <0.0001 (mean follow-up: 11±1.4 mo). The IOP was significantly reduced in both groups ( P <0.0001). Ocular hypotensive medication was reduced significantly from 2.7±0.7 to 0.2±0.5 ( P <0.0001). No significant differences were found in IOP-lowering medication between groups (PSM alone, 0.2±0.08; PSM+phacoemulsification, 0.1±0.1; P =0.2). At the final visit, 70.3% were considered as complete success and 12.5% as qualified success. The most common adverse event was clinical hypotony (7.8%) followed by hyphema (4.7%), and anterior chamber reformation (1.6%). Overall, 1.6% required needling and 15.6% surgical revision to restore the flow. CONCLUSION Glaucoma surgery with the PSM and mitomycin C was efficacious and safe in the short term, either alone or in combination with cataract surgery, and may be considered a surgical option for lowering IOP in primary open angle glaucoma.
Collapse
|