1
|
Dudhe SS, Mishra G, Parihar P, Nimodia D, Kumari A. Radiation Dose Optimization in Radiology: A Comprehensive Review of Safeguarding Patients and Preserving Image Fidelity. Cureus 2024; 16:e60846. [PMID: 38910606 PMCID: PMC11191847 DOI: 10.7759/cureus.60846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Accepted: 05/22/2024] [Indexed: 06/25/2024] Open
Abstract
Radiation dose optimization in radiology is a critical aspect of modern healthcare, aimed at balancing the necessity of diagnostic imaging with the imperative of patient safety. This comprehensive review explores the fundamental principles, techniques, and considerations in optimizing radiation dose to safeguard patients while preserving image fidelity. Beginning with acknowledging the inherent risks associated with medical radiation exposure, the review highlights strategies such as the As Low as Reasonably Achievable (ALARA) principle, technological advancements, and quality assurance measures to minimize radiation dose without compromising diagnostic accuracy. Regulatory guidelines and the importance of patient education and informed consent are also discussed. Through a synthesis of current knowledge and emerging trends, the review underscores the pivotal role of radiation dose optimization in radiology practice. Furthermore, it emphasizes the need for ongoing research and collaboration to advance dose reduction strategies, establish standards for radiation safety, and explore personalized dose optimization approaches. By prioritizing radiation dose optimization, healthcare providers can ensure the highest standards of patient care while minimizing potential risks associated with medical radiation exposure.
Collapse
Affiliation(s)
- Sakshi S Dudhe
- Radiodiagnosis, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Gaurav Mishra
- Radiodiagnosis, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Pratapsingh Parihar
- Radiodiagnosis, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Devyansh Nimodia
- Radiodiagnosis, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Anjali Kumari
- Radiodiagnosis, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| |
Collapse
|
2
|
Bahonar BM, Changizi V, Ebrahiminia A, Baradaran S. Prediction of breast dose in chest CT examinations using adaptive neuro-fuzzy inference system (ANFIS). Phys Eng Sci Med 2023; 46:1071-1080. [PMID: 37245194 PMCID: PMC10225119 DOI: 10.1007/s13246-023-01276-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2022] [Accepted: 05/05/2023] [Indexed: 05/29/2023]
Abstract
In chest computed tomography (CT), the breasts located within the scan range receive a substantial radiation dose. Due to the risk of breast-related carcinogenesis, analyzing the breast dose for justification of CT examinations seems necessary. The main goal of this study is to overcome the limitations of conventional dosimetry methods, such as thermoluminescent dosimeters (TLDs) by introducing the adaptive neuro-fuzzy inference system (ANFIS) approach. In this study, the breast dose of 50 adult female patients who underwent chest CT examinations was measured directly by TLDs. Then, the ANFIS model was developed with four inputs including dose length product (DLP), volumetric CT dose index (CTDIvol), total mAs, and size-specific dose estimate (SSDE), and one output (TLD dose). Additionally, multiple linear regression (MLR) as a traditional prediction model was used for linear modeling and its results were compared with the ANFIS. The TLD reader results showed that the breast dose value was 12.37 ± 2.46 mGy. Performance indices of the ANFIS model, including root mean square error (RMSE) and correlation coefficient (R), were calculated at 0.172 and 0.93 for the testing dataset, respectively. Also, the ANFIS model had superior performance in predicting the breast dose than the MLR model (R = 0.805). This study demonstrates that the proposed ANFIS model is efficient for patient dose prediction in CT scans. Therefore, intelligence models such as ANFIS are suggested to estimate and optimize patient dose in CT examinations.
Collapse
Affiliation(s)
- Bahareh Moradmand Bahonar
- Department of Radiology and Radiotherapy Technology, Tehran University of Medical Sciences, Tehran, Iran
| | - Vahid Changizi
- Department of Radiology and Radiotherapy Technology, Tehran University of Medical Sciences, Tehran, Iran.
| | - Ali Ebrahiminia
- Department of Medical Physics, School of Medicine, Guilan University of Medical Sciences, Rasht, Iran
| | | |
Collapse
|
3
|
Jeyasugiththan J, Karunarathna S, Satharasinghe D, Hishaam U, Pallewatte A. Evaluation of radiation dose in multi-slice computed tomography protocols of head and neck regions. RADIATION PROTECTION DOSIMETRY 2023:ncad142. [PMID: 37103965 DOI: 10.1093/rpd/ncad142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 04/01/2023] [Accepted: 04/05/2022] [Indexed: 06/19/2023]
Abstract
In head and neck computed tomography (CT) imaging, the optimisation of radiation dose is crucial due to the presence of radio-sensitive organs. This study aimed to evaluate the radiation dose in multi-slice CT for head and neck examinations. Volume CT dose index, dose length product and effective dose (E) were assessed for 10 head and neck CT scans performed on 292 adult patients (mean age 49.2 ± 15.9 y). The study resulted in median E values of 0.82, 1.62, 2.43, 0.93, 1.70, 0.83, 3.55, 6.25, 2.19 and 5.26 mSv, respectively, for sinuses (non-contrast (NC)), sinuses (NC) and contrast-enhanced (CE), petrous bone (PTB)/internal auditory meatus (IAM) (NC + CE), PTB/IAM (NC), orbit (NC + CE), orbit (NC), brain with the orbit (NC), brain CT angiography (CTA) subtraction, neck (NC) and brain/neck (NC). Furthermore, the overall radiation doses of this institution were found to be below the values suggested by similar studies. However, optimisation of the dose is required for brain CTA.
Collapse
Affiliation(s)
| | - Sanjaya Karunarathna
- Department of Nuclear Science, Faculty of Science, University of Colombo, Colombo 00300, Sri Lanka
- Department of Radiology, National Hospital of Sri Lanka, Colombo 00700, Sri Lanka
| | - Duminda Satharasinghe
- Department of Nuclear Science, Faculty of Science, University of Colombo, Colombo 00300, Sri Lanka
| | - Urshella Hishaam
- Department of Nuclear Science, Faculty of Science, University of Colombo, Colombo 00300, Sri Lanka
| | - Aruna Pallewatte
- Department of Radiology, National Hospital of Sri Lanka, Colombo 00700, Sri Lanka
| |
Collapse
|
4
|
Amalaraj T, Satharasinghe D, Pallewatte A, Jeyasugiththan J. Establishment of national diagnostic reference levels for computed tomography procedures in Sri Lanka: first nationwide dose survey. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2022; 42:021504. [PMID: 34875641 DOI: 10.1088/1361-6498/ac40e8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Accepted: 12/06/2021] [Indexed: 06/13/2023]
Abstract
The main purpose of this study was to establish for the first time national diagnostic reference levels (NDRLs) for common computed tomography (CT) procedures in Sri Lanka. Patient morphometric data, exposure parameters and dose data such as volume CT dose index (CTDIvol) and dose-length product (DLP) were collected from 5666 patients who underwent 22 types of procedure. The extreme dose values were filtered before analysis to ensure that the data come from standard size patients. The median of the dose distribution was calculated for each institution, and the third quartile value of the median distribution was considered as the NDRL. Based on the inclusion and exclusion criteria, data from 4592 patients and 17 procedure types were considered for establishment of a NDRL, covering 41% of the country's CT machines. The proposed NDRLs based on CTDIvoland DLP were: non-contrast-enhanced (NC) head, 82.2 mGy/1556 mGy cm; contrast-enhanced (CE) head, 82.2 mGy/1546 mGy cm; chest NC, 7.4 mGy/350 mGy cm; chest CE, 8.3 mGy/464 mGy cm; abdomen NC, 10.5 mGy/721 mGy cm; abdomen arterial (A) phase, 13.4 mGy/398 mGy cm; abdomen venous (V) phase, 10.8 mGy/460 mGy cm; abdomen delay (D) phase, 12.6 mGy/487 mGy cm; sinus NC, 30.2 mGy/452 mGy cm; lumbar spine NC, 24.1 mGy/1123 mGy cm; neck NC, 27.5 mGy/670 mGy cm; high-resolution CT of chest, 10.3 mGy/341 mGy cm; kidneys ureters and bladder NC, 19.4 mGy/929 mGy cm; chest to pelvis (CAP) NC, 10.8 mGy/801 mGy cm; CAP A, 10.4 mGy/384 mGy cm; CAP V, 10.5 mGy/534 mGy cm; CAP D, 16.8 mGy/652 mGy cm. Although the proposed NDRLs are comparable with those of other countries, the observed broad dose distributions between the CT machines within Sri Lanka indicate that dose optimisation strategies for the country should be implemented for most of the CT facilities.
Collapse
Affiliation(s)
- T Amalaraj
- Department of Nuclear Science, University of Colombo, Colombo, Sri Lanka
| | | | - Aruna Pallewatte
- Department of Radiology, National Hospital of Sri Lanka, Colombo, Sri Lanka
| | | |
Collapse
|
5
|
Brooke JP, Hall IP. Novel Thoracic MRI Approaches for the Assessment of Pulmonary Physiology and Inflammation. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1304:123-145. [PMID: 34019267 DOI: 10.1007/978-3-030-68748-9_8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Excessive pulmonary inflammation can lead to damage of lung tissue, airway remodelling and established structural lung disease. Novel therapeutics that specifically target inflammatory pathways are becoming increasingly common in clinical practice, but there is yet to be a similar stepwise change in pulmonary diagnostic tools. A variety of thoracic magnetic resonance imaging (MRI) tools are currently in development, which may soon fulfil this emerging clinical need for highly sensitive assessments of lung structure and function. Given conventional MRI techniques are poorly suited to lung imaging, alternate strategies have been developed, including the use of inhaled contrast agents, intravenous contrast and specialized lung MR sequences. In this chapter, we discuss technical challenges of performing MRI of the lungs and how they may be overcome. Key thoracic MRI modalities are reviewed, namely, hyperpolarized noble gas MRI, oxygen-enhanced MRI (OE-MRI), ultrashort echo time (UTE) MRI and dynamic contrast-enhanced (DCE) MRI. Finally, we consider potential clinical applications of these techniques including phenotyping of lung disease, evaluation of novel pulmonary therapeutic efficacy and longitudinal assessment of specific patient groups.
Collapse
Affiliation(s)
- Jonathan P Brooke
- Department of Respiratory Medicine, University of Nottingham, Queens Medical Centre, Nottingham, UK.
| | - Ian P Hall
- Department of Respiratory Medicine, University of Nottingham, Queens Medical Centre, Nottingham, UK.
| |
Collapse
|
6
|
Tsapaki V. Radiation dose optimization in diagnostic and interventional radiology: Current issues and future perspectives. Phys Med 2020; 79:16-21. [PMID: 33035737 DOI: 10.1016/j.ejmp.2020.09.015] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Revised: 09/04/2020] [Accepted: 09/19/2020] [Indexed: 12/16/2022] Open
Affiliation(s)
- Virginia Tsapaki
- Dosimetry and Medical Radiation Physics Section, International Atomic Energy Agency, Austria.
| |
Collapse
|
7
|
Ebrahiminia A, Asadinezhad M, Mohammadi F, Khoshgard K. EYE LENS DOSE OPTIMIZATION THROUGH GANTRY TILTING IN BRAIN CT SCAN: THE POTENTIAL EFFECT OF THE RADIOLOGICAL TECHNOLOGISTS' TRAINING. RADIATION PROTECTION DOSIMETRY 2020; 189:527-533. [PMID: 32472135 DOI: 10.1093/rpd/ncaa073] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2020] [Revised: 04/16/2020] [Accepted: 04/25/2020] [Indexed: 06/11/2023]
Abstract
This study was designed to evaluate the effect of the radiological technologists' training on optimising the eye lens dose in brain computed tomography (CT) examinations. The lens dose of 50 adult patients was measured using thermoluminescent dosimeters before and after technologists' training. Dose values of lenses, dose length product (DLP), volumetric CT dose index (CTDIvol) as well as image quality in terms of quantitative (contrast to noise ratio and signal to noise ratio) and subjective (artefact) parameters were compared before and after training. Lens dose values were 31.57 ± 9.84 mGy and 5.36 ± 1.53 mGy before and after training, respectively, which was reduced by ~83% (p < 0.05). The values of DLP, CTDIvol and image quality parameters were not significantly different (p > 0.05) and all images were diagnostically acceptable. Excluding the orbits from the scanning range is an efficient approach to optimize the lens dose; the training of the technologists has also a pivotal role in dose reducing.
Collapse
Affiliation(s)
- Ali Ebrahiminia
- Department of Medical Physics, School of Medicine, Guilan University of Medical Sciences, Rasht, Iran
| | - Mohsen Asadinezhad
- Department of Radiology Technology, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Fereshteh Mohammadi
- Department of Radiology Technology, School of Paramedical Sciences, Guilan University of Medical Sciences, Rasht, Iran
| | - Karim Khoshgard
- Department of Medical Physics, School of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran
| |
Collapse
|
8
|
Yee J, McFarland E. Extracolonic findings and radiation at CT colonography: what the referring provider needs to know. Abdom Radiol (NY) 2018; 43:554-565. [PMID: 29450613 DOI: 10.1007/s00261-018-1461-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
A better understanding of the risks and benefits of extracolonic findings and radiation dose will aid in the safe and proper implementation of CT colonography in clinical practice. The majority of extracolonic findings in screening patients are benign and can be ignored by referring physicians. Radiologists also need to be responsible in reporting extracolonic findings. Referring providers must be knowledgeable about the theoretic risks and controversies regarding the use of ionizing radiation. Screening CT colonography imparts a low-level of radiation to patients that is equivalent or less than annual background dose.
Collapse
Affiliation(s)
- Judy Yee
- Department of Radiology, Albert Einstein College of Medicine, Montefiore Medical Center, 111 East 210th St, Bronx, NY, 10467, USA.
| | - Elizabeth McFarland
- SSM St. Joseph Health Center, 300 Capitol Drive, St. Charles, MO, 63301, USA
| |
Collapse
|
9
|
Aburjaile W, Mourao A. Development of a chest phantom for testing in Computed Tomography scans. Radiat Phys Chem Oxf Engl 1993 2017. [DOI: 10.1016/j.radphyschem.2017.01.031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
10
|
Ohana M, Labani A, Jeung M, Ghannudi S, Gaertner S, Roy C. Iterative reconstruction in single source dual-energy CT pulmonary angiography: Is it sufficient to achieve a radiation dose as low as state-of-the-art single-energy CTPA? Eur J Radiol 2015. [DOI: 10.1016/j.ejrad.2015.07.010] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
11
|
|