1
|
Meer E, Patel M, Chan D, Sheikh AM, Nicolaou S. Dual-Energy Computed Tomography and Beyond: Musculoskeletal System. Radiol Clin North Am 2023; 61:1097-1110. [PMID: 37758359 DOI: 10.1016/j.rcl.2023.05.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
Traditional monoenergetic computed tomography (CT) scans in musculoskeletal imaging provide excellent detail of bones but are limited in the evaluation of soft tissues. Dual-energy CT (DECT) overcomes many of the traditional limitations of CT and offers anatomical details previously seen only on MR imaging. In addition, DECT has benefits in the evaluation and characterization of arthropathies, bone marrow edema, and collagen applications in the evaluation of tendons, ligaments, and vertebral discs. There is current ongoing research in the application of DECT in arthrography and bone mineral density calculation.
Collapse
Affiliation(s)
- Emtenen Meer
- Vancouver General Hospital-University of British Columbia, Vancouver, British Columbia, Canada; King Faisal Specialist Hospital and Research Centre, Jeddah, Saudi Arabia.
| | - Mitulkumar Patel
- Vancouver General Hospital-University of British Columbia, Vancouver, British Columbia, Canada
| | - Darren Chan
- Vancouver General Hospital-University of British Columbia, Vancouver, British Columbia, Canada
| | - Adnan M Sheikh
- Vancouver General Hospital-University of British Columbia, Vancouver, British Columbia, Canada
| | - Savvas Nicolaou
- Vancouver General Hospital-University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
2
|
Cicero G, Ascenti G, Albrecht MH, Blandino A, Cavallaro M, D'Angelo T, Carerj ML, Vogl TJ, Mazziotti S. Extra-abdominal dual-energy CT applications: a comprehensive overview. Radiol Med 2020; 125:384-397. [PMID: 31925704 DOI: 10.1007/s11547-019-01126-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Accepted: 12/27/2019] [Indexed: 12/12/2022]
Abstract
Unlike conventional computed tomography, dual-energy computed tomography is a relatively novel technique that exploits ionizing radiations at different energy levels. The separate radiation sets can be achieved through different technologies, such as dual source, dual layers or rapid switching voltage. Body tissue molecules vary for their specific atomic numbers and electron density, and the interaction with different sets of radiations results in different attenuations, allowing to their final distinction. In particular, iodine recognition and quantification have led to important information about intravenous contrast medium delivery within the body. Over the years, useful post-processing algorithms have also been validated for improving tissue characterization. For instance, contrast resolution improvement and metal artifact reduction can be obtained through virtual monoenergetic images, dose reduction by virtual non-contrast reconstructions and iodine distribution highlighting through iodine overlay maps. Beyond the evaluation of the abdominal organs, dual-energy computed tomography has also been successfully employed in other anatomical districts. Although lung perfusion is one of the most investigated, this evaluation has been extended to narrowly fields of application, such as musculoskeletal, head and neck, vascular and cardiac. The potential pool of information provided by dual-energy technology is already wide and not completely explored, yet. Therefore, its performance continues to raise increasing interest from both radiologists and clinicians.
Collapse
Affiliation(s)
- Giuseppe Cicero
- Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino" Via Consolare Valeria 1, 98100, Messina, Italy.
| | - Giorgio Ascenti
- Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino" Via Consolare Valeria 1, 98100, Messina, Italy
| | - Moritz H Albrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany
| | - Alfredo Blandino
- Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino" Via Consolare Valeria 1, 98100, Messina, Italy
| | - Marco Cavallaro
- Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino" Via Consolare Valeria 1, 98100, Messina, Italy.,Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany
| | - Tommaso D'Angelo
- Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino" Via Consolare Valeria 1, 98100, Messina, Italy
| | - Maria Ludovica Carerj
- Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino" Via Consolare Valeria 1, 98100, Messina, Italy
| | - Thomas J Vogl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany
| | - Silvio Mazziotti
- Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, University of Messina, Policlinico "G. Martino" Via Consolare Valeria 1, 98100, Messina, Italy
| |
Collapse
|