1
|
Iwaniak K, Kaczorowski W, Burnat B, Grabarczyk J. Impact of the Applied Electrode System on Properties of Electrodeposited Calcium Phosphate Coatings. MATERIALS (BASEL, SWITZERLAND) 2025; 18:539. [PMID: 39942205 PMCID: PMC11818842 DOI: 10.3390/ma18030539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/27/2024] [Revised: 01/15/2025] [Accepted: 01/22/2025] [Indexed: 02/16/2025]
Abstract
The morphology and physicochemical properties of electrochemically deposited CaP coatings depend on the applied process parameters; however, the influence of different electrode systems has not been studied so far. In this work, the possibility of electrochemical deposition of CaP coatings on Ti6Al7Nb alloy using different electrode systems (two-electrode and three-electrode) and the influence of the electrode system and selected ranges of deposition parameters on the properties of the deposited CaP coatings were investigated. The morphology and physicochemical properties of the CaP coatings were characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), Raman spectroscopy, X-ray diffraction (XRD), and corrosion studies. The results confirmed the effective electrodeposition of CaP coatings using both electrode systems. The applied electrode system and deposition parameters cause changes in the morphology of the obtained coatings. Chemical structure analysis confirmed the presence of mainly hydroxyapatite in the deposited CaP coatings. With the change in voltage/potential in a more cathodic direction, in addition to hydroxyapatite, a dicalcium phosphate dihydrate (DCPD) structure appears. The corrosion tests have shown that the applied deposition parameters have an impact on corrosion resistance and the deposited coatings exhibited protective properties against corrosion under physiological conditions. The CaP coatings with optimal properties for biomedical applications were deposited at a voltage of -4 V in the two-electrode system and a potential of -4 VSCE in the three-electrode system.
Collapse
Affiliation(s)
- Klaudia Iwaniak
- Institute of Material Science and Engineering, Lodz University of Technology, 1/15 Stefanowskiego Str., 90-537 Lodz, Poland; (W.K.)
| | - Witold Kaczorowski
- Institute of Material Science and Engineering, Lodz University of Technology, 1/15 Stefanowskiego Str., 90-537 Lodz, Poland; (W.K.)
| | - Barbara Burnat
- University of Lodz, Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, 12 Tamka Str., 91-403 Lodz, Poland
| | - Jacek Grabarczyk
- Institute of Material Science and Engineering, Lodz University of Technology, 1/15 Stefanowskiego Str., 90-537 Lodz, Poland; (W.K.)
| |
Collapse
|
2
|
Emmert AS, Ruan T, Sherenian MG, Assa'ad AH, Leitsinger N, Schultz L, Jain VV, Sturm PF, Jones AC. Prevalence of metal hypersensitivity in pediatric spine surgery. Spine Deform 2025:10.1007/s43390-024-01030-7. [PMID: 39808266 DOI: 10.1007/s43390-024-01030-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Accepted: 12/19/2024] [Indexed: 01/16/2025]
Abstract
PURPOSE Delayed metal hypersensitivity reactions can cause complications in spine surgery. Currently, there is no information on the prevalence of metal hypersensitivity in pediatric patients undergoing spine surgery. The objective of this study is to determine the prevalence of metal hypersensitivity in pediatric patients undergoing spinal instrumentation. METHODS Retrospective chart review of patients who underwent spinal instrumentation with or without fusion at a single institution, from January 1, 2014, to December 31, 2020, was performed. Patients were pre-screened for history of allergic diseases, including previous reaction to metals, prior to surgery. Patch metal allergy testing (PMAT) for metal hypersensitivity was also performed. RESULTS Of the 796 pediatric patients who underwent spinal instrumentation procedures from 2014 to 2020, 118 (15%) screened positive for metal hypersensitivity. However, the number of patients with documented evidence of metal hypersensitivity diminished to 26 (3%) after PMAT verification. Nickel hypersensitivity was most prevalent, with 20 patients (16.9% of positive screening; 2.5% of all instrumented patients) demonstrating positive skin patch tests. The other most prevalent metal hypersensitivities included cobalt in 9 patients (7.6%; 1.1%), manganese in 3 patients (2.5%; 0.4%), and copper in 1 patient (0.8%; 0.1%). with a number needed to treat (NNT) of 5. CONCLUSIONS This study suggests that routine pre-operative PMAT is not necessary in all pediatric spine patients yet should be considered if patients report a history of prior metal hypersensitivity reactions.
Collapse
Affiliation(s)
- A Scott Emmert
- Division of Orthopaedic Surgery, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Cincinnati, OH, 45242, USA
| | - Tiffany Ruan
- Division of Orthopaedic Surgery, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Cincinnati, OH, 45242, USA
| | - Michael G Sherenian
- Division of Allergy and Immunology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Amal H Assa'ad
- Division of Allergy and Immunology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Nichole Leitsinger
- Division of Orthopaedic Surgery, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Cincinnati, OH, 45242, USA
| | - Lindsay Schultz
- Division of Orthopaedic Surgery, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Cincinnati, OH, 45242, USA
| | - Viral V Jain
- Division of Orthopaedic Surgery, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Cincinnati, OH, 45242, USA
| | - Peter F Sturm
- Division of Orthopaedic Surgery, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Cincinnati, OH, 45242, USA
| | - Alvin C Jones
- Division of Orthopaedic Surgery, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Cincinnati, OH, 45242, USA.
| |
Collapse
|
3
|
Pacheco KA, Thyssen JP. Contact Dermatitis From Biomedical Devices, Implants, and Metals-Trouble From Within. THE JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY. IN PRACTICE 2024; 12:2280-2295. [PMID: 39067854 DOI: 10.1016/j.jaip.2024.07.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 07/22/2024] [Accepted: 07/22/2024] [Indexed: 07/30/2024]
Abstract
Allergic contact dermatitis is characterized by its appearance of red, raised and infiltrated, scaling or scabbed skin and intense pruritus, and distinguished from irritant contact dermatitis by its specific immune process and histopathology. Many contact allergens are low-molecular- weight chemicals including metals such as nickel, cobalt, and chromium, preservatives, and adhesives. When such materials are used internally in biomedical devices, they are similarly capable of causing sensitization and an inflammatory response. Sometimes, the reaction remains internal, and presents as swelling, pain, stiffness, decreased range of motion, and internal itching around the implant. Such reactions may, in some cases, also extend to include a localized or, rarely, systemic contact dermatitis indicative of the same process. This review will present an overview of reported skin and local internal reactions to orthopedic implants, which are the largest category of implanted internal metal devices. Immune reactions to smaller categories of medical appliances include cardiac devices and vascular stents, neuromodulation devices, diabetic appliances, Nuss bar surgery for pectus excavatum, and dental and spinal implants. We will review the available diagnostic tools, the consensus on interpretation, and reported strategies for treatment.
Collapse
Affiliation(s)
- Karin A Pacheco
- Division of Environmental & Occupational Health Sciences, National Jewish Health, Denver, Colo; Environmental & Occupational Health Division, Colorado School of Public Health, Aurora, Colo.
| | - Jacob P Thyssen
- Department of Dermatology and Venereology, Bispebjerg Hospital, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
4
|
Pesqué D, Aerts O, Bizjak M, Gonçalo M, Dugonik A, Simon D, Ljubojević-Hadzavdić S, Malinauskiene L, Wilkinson M, Czarnecka-Operacz M, Krecisz B, John SM, Balato A, Ayala F, Rustemeyer T, Giménez-Arnau AM. Differential diagnosis of contact dermatitis: A practical-approach review by the EADV Task Force on contact dermatitis. J Eur Acad Dermatol Venereol 2024; 38:1704-1722. [PMID: 38713001 DOI: 10.1111/jdv.20052] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 03/15/2024] [Indexed: 05/08/2024]
Abstract
The diagnosis of eczema ('dermatitis') is mostly clinical and depends on the clinical history and exploratory objective findings (primary lesions, patterns). Contact dermatitis remains as an important condition in the group of eczematous disorders, with important socioeconomic and occupational relevance. Although irritant and allergic contact dermatitis have a different pathogenesis, both are characterized by a rather typical morphology, are triggered by external factors and tend to occur primarily in the area of contact with the exogenous agent. In addition, allergic and irritant dermatitis may also co-exist. The importance of diagnosing contact dermatitis, especially when allergic in nature, is both due to the possibility of avoiding the trigger, and due to its role in aggravating other skin conditions. Nevertheless, the heterogeneity of clinical presentations in daily practice may pose an important challenge for the suspicion and correct diagnosis of contact dermatitis. Furthermore, other conditions, with different pathogenesis and treatment, may clinically simulate contact dermatitis. The Task Force aims to conduct a review of the unifying clinical features of contact dermatitis and characterize its main clinical phenotypes, and its simulators, in order to contribute to an early suspicion or recognition of contact dermatitis and enable a correct differential diagnosis.
Collapse
Affiliation(s)
- David Pesqué
- Dermatology Department, Hospital del Mar Research Institute, Department of Medicine, Universitat Autònoma de Barcelona (UAB), Barcelona, Spain
| | - Olivier Aerts
- Department of Dermatology, University Hospital Antwerp (UZA) and Research Group Immunology, University of Antwerp, Antwerp, Belgium
| | - Mojca Bizjak
- Division of Allergy, University Clinic of Respiratory and Allergic Diseases Golnik, Golnik, Slovenia
| | - Margarida Gonçalo
- Department of Dermatology, Coimbra University Hospital, Coimbra, Portugal
- Faculty of Medicine, University of Coimbra, Coimbra, Portugal
| | - Aleksandra Dugonik
- Department of Dermatology, University Medical Centre Maribor, Maribor, Slovenia
| | - Dagmar Simon
- Department of Dermatology, Inselspital University Hospital of Bern, Bern, Switzerland
| | - Suzana Ljubojević-Hadzavdić
- Department of Dermatology and Venereology, University Hospital Center Zagreb, School of Medicine University of Zagreb, Zagreb, Croatia
| | - Laura Malinauskiene
- Faculty of Medicine, Institute of Clinical Medicine, Clinic of Chest Diseases, Immunology and Allergology, Vilnius University, Vilnius, Lithuania
| | - Mark Wilkinson
- Leeds Centre for Dermatology, Leeds Teaching Hospitals NHS Trust, Chapel Allerton Hospital, Leeds, UK
| | | | - Beata Krecisz
- Collegium Medicum, Jan Kochanowski University Kielce, Kielce, Poland
| | - Swen M John
- Department of Dermatology, Environmental Medicine, Osnabrueck University, Osnabrueck, Germany
| | - Anna Balato
- Dermatology Unit, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Fabio Ayala
- Department of Clinical Medicine and Surgery, University of Naples Federico II, Naples, Italy
| | - Thomas Rustemeyer
- Dermato-Allergology and Occupational Dermatology, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | - Ana M Giménez-Arnau
- Dermatology Department, Hospital del Mar Research Institute, Universitat Pompeu Fabra (UPF), Barcelona, Spain
| |
Collapse
|
5
|
Cordunianu MA, Vulcu Cordunianu AG, Antoniac I, Luca A, Niculescu M, Chiriac CO, Corneschi I, Mohor CI. Experimental Analysis of a Failed Gamma Nail: A Case Report and Literature Review. Healthcare (Basel) 2024; 12:1578. [PMID: 39201137 PMCID: PMC11353889 DOI: 10.3390/healthcare12161578] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Revised: 07/25/2024] [Accepted: 08/06/2024] [Indexed: 09/02/2024] Open
Abstract
The Gamma Nail represents one of the most popular and efficient implants for treating proximal femoral fractures. Our paper reports a case of a failed Gamma Nail which was used for the surgical treatment of a 69-year-old woman with a right femoral trochanteric fracture due to a car accident. After the surgical intervention, 6 months later, the patient presented to the hospital reporting pain and limited mobility of the right hip. An X-ray was performed at the level of the pelvis, which highlighted the fracture nonunion and the implant failure. The implant removal and its replacement with a dynamic condylar screw system (DCS) was decided. Because Gamma Nail failures are rare occurrences, the implant was subjected to analyses and experimental determinations to find out the cause. For the implant analyses, a stereomicroscope, an optical microscope, and scanning electron microscopy were used. After the tests were conducted, preparation and processing irregularities as causes of the implant failure were eliminated. Also, the experimental analyses showed that the Gamma Nail did comply with chemical composition and microstructure regulations. Thus, it was concluded that the implant failed due to the mechanical overloading caused by surgical technique errors.
Collapse
Affiliation(s)
| | | | - Iulian Antoniac
- Faculty of Material Science and Engineering, University Politehnica of Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania
| | - Andrei Luca
- Faculty of Medicine, Titu Maiorescu University, 67A Gheorghe Petrascu, 031593 Bucharest, Romania
| | - Marius Niculescu
- Faculty of Medicine, Titu Maiorescu University, 67A Gheorghe Petrascu, 031593 Bucharest, Romania
| | - Cristian Ovidiu Chiriac
- Department of Neurologic Recovery, Central Military Emergency University Hospital Carol Davila, 134 Calea Plevnei, District 1, 010825 Bucharest, Romania
| | - Iuliana Corneschi
- Faculty of Material Science and Engineering, University Politehnica of Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania
| | - Cosmin Ioan Mohor
- Faculty of Medicine, Lucian Blaga University of Sibiu, 10 Victoriei Boulevard, 550024 Sibiu, Romania
| |
Collapse
|
6
|
Abouharb A, Joseph PJS, Pandit H. Existing and Novel Assessment Methods for Metal Sensitivity in Elective Lower-Limb Arthroplasty-A Scoping Review. Arthroplast Today 2024; 28:101462. [PMID: 39170964 PMCID: PMC11338134 DOI: 10.1016/j.artd.2024.101462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 05/13/2024] [Accepted: 06/09/2024] [Indexed: 08/23/2024] Open
Abstract
Background Metal sensitivity is a possible cause for revision in elective lower-limb arthroplasty. This scoping review aims to identify and evaluate all existing and novel assessment methods for metal sensitivity in elective lower-limb arthroplasty. Methods The Cochrane Central Register of Controlled Trials (CENTRAL), Ovid Medical Literature Analysis and Retrieval System Online (MEDLINE), PubMed, and Google Scholar databases were searched for studies published between January 1, 2000, and September 1, 2023. Studies evaluating one or more metal sensitivity assessment method preoperatively, perioperatively, or postoperatively were included. Studies were grouped based on the assessment methods reported and summarized based on the study design, outcome measure, results, and comments on the method's validity. Results A total of 1220 results were screened, with 39 results (15 retrospective cohort studies, 11 prospective cohort studies, 6 case reports, 5 randomized controlled trials, and 2 case control studies) included, identifying 12 assessment methods. The most used one was patch testing, featuring in 17 studies (43.6%). Lymphocyte transformation assay/testing featured in 12 studies (30.8%). Plasma/serum concentration of metal ions featured in 6 studies (15.4%). Patient history and serum cytokine testing featured in 7 (17.9%) and 4 (10.3%) studies each. Generalized serum inflammatory markers featured in 3 studies (7.7%). The remaining 6 methods each featured in one or 2 studies. Evidence of the reliability of most metrics was limited. Conclusions Several assessment methods were identified. However, evidence of any methods reliably predicting and diagnosing the occurrence of metal sensitivity was limited. There is a need for improved metrics of metal hypersensitivity.
Collapse
Affiliation(s)
| | | | - Hemant Pandit
- Leeds Teaching Hospitals NHS Trust, St. James's University Hospital, Leeds, UK
- Leeds Institute of Rheumatic and Musculoskeletal Medicine (LIRMM), University of Leeds, Leeds, West Yorkshire, UK
| |
Collapse
|
7
|
Richard OK, Liens A, Muirhead D, Weber K. Tissue response following implantation with the posterior dynamic distraction device (PDDD) in adolescent idiopathic scoliosis (AIS). EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2024; 33:2512-2521. [PMID: 38584244 DOI: 10.1007/s00586-024-08200-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 02/13/2024] [Accepted: 02/20/2024] [Indexed: 04/09/2024]
Abstract
PURPOSE The PDDD is a ratchet-based, unidirectional expandable rod to treat adolescent idiopathic scoliosis (AIS), primarily by correcting scoliotic deformity without full spinal fusion. We hypothesized that the device will be fully tolerated by the host and, if aseptic screw loosening occurs, it will be unrelated to wear particle formation. METHODS This study comprised tissue samples from seven patients from a prospective study (NCT04296903) to assess the PDDD's safety and benefits, reoperated due to complications. Host response was assessed from histological slides (four levels/implant) in accordance with GLP and ISO10993-6:2016. The elementary chemical composition of wear particles present in tissue sections was quantified by energy dispersive X-ray spectroscopy (EDX). RESULTS Host reaction was minor, characterized by low levels of diverse inflammatory cells, mild fibrosis, occasional small necrotic foci, neovascularization, hemorrhage, and, rarely, small bone fragments. Twenty-four of 28 tissue sections displayed varying degrees of wear particles (black discoloration), and most sections (17) were scored as 1 (< 25% of the sample). The discoloration observed corresponded to black-appearing, fine granular pigment. EDX analysis confirmed particles were composed of titanium, aluminum, and vanadium. Twenty-six of 28 samples were scored zero for necrosis and 2/28 were scored 1. Eleven samples were scored zero for fibrosis, 12 as 1, and five as 2. No aseptic screw loosening occurred. CONCLUSION The PDDD induced minimal host reaction with little or no degeneration, inflammation or fibrosis. No changes present could be expected to promote device failure. The PDDD implant for treating AIS is well-tolerated and locally safe.
Collapse
Affiliation(s)
| | | | | | - Klaus Weber
- AnaPath Services GmbH, Liestal, Switzerland.
| |
Collapse
|
8
|
Entezami P, Field NC, Qian J, Yamamoto J. Delayed hypersensitivity reaction to a dural repair substitute. Br J Neurosurg 2024; 38:761-764. [PMID: 34397313 DOI: 10.1080/02688697.2021.1967879] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Accepted: 08/09/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND Modern neurosurgeons commonly rely on dural grafts to aid in obtaining watertight closures when the native dura itself cannot be approximated. CASE PRESENTATION We present a patient who developed a symptomatic, delayed hypersensitivity reaction to a cellulose-based synthetic dural graft, which resolved after reoperation and removal of the graft. DISCUSSION Dural grafts are a safe and common implant utilized in neurosurgery. Nevertheless, as with all implanted material, there is a chance for symptomatic immune reactions to occur. CONCLUSION This type of response is exceedingly uncommon, but recognition of this rare presentation may help other providers recognize it in the future.
Collapse
Affiliation(s)
- Pouya Entezami
- Department of Neurosurgery, Albany Medical Center, Albany, NY, USA
| | - Nicholas C Field
- Department of Neurosurgery, Albany Medical Center, Albany, NY, USA
| | - Jiang Qian
- Department of Pathology, Albany Medical Center, Albany, NY, USA
| | - Junichi Yamamoto
- Department of Neurosurgery, Albany Medical Center, Albany, NY, USA
| |
Collapse
|
9
|
Eren Belgin E, Genç D, Tekin L, Sezgin S, Aladağ A. Anti-Inflammatory Effect of Dental Pulpa Mesenchymal Stem Cell Exosomes Loaded Mucoadhesive Hydrogel on Mice with Dental Nickel Hypersensitivity. Macromol Biosci 2024; 24:e2300352. [PMID: 38284435 DOI: 10.1002/mabi.202300352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 10/15/2023] [Indexed: 01/30/2024]
Abstract
In this study, the anti-inflammatory effect of dental pulp mesenchymal stem cell (MSCs) exosomes loaded to mucoadhesive hydrogel is investigated in a dental nickel hypersensitivity murine model. After culture of dental pulp MSCs in the third passage MSCs are loaded to a mucoadhesive hydrogel based on chitosan, cross-linked with genipin and modified with catechol groups. A dental nickel hypersensitivity model is created by administering NiCl2 and 10 µg mL-1 lipopolysaccharide to 4-6 week-old Balb-c mice by intradermal injection. In mice treated with dental pulp MSC exosomes and exosomes in hydrogel, interferron gamma (IFN-γ) secreting CD4+T lymphocyte ratios significantly increase compared to the untreated group (p < 0.05). IFN-γ and interleukin 10 (IL-10) expression in buccal mucosa tissue sections and IFN-γ secreting CD4+T lymphocyte ratios are found to be significantly higher in mice treated with dental pulpa MSCs (DPMSCs) exosomes and DPMSCs exosomes in hydrogel compared to the untreated group (p < 0.05). According to flow cytometry results, IL-4 secreting CD4+T lymphocytes are found to be significantly decreased in DPMSCs exosomes group compared to dental nickel hypersensitivity group (p < 0.05). Administration of DPMSCs exosomes with mucoadhesive hydrogel may be an alternative to current medication in the treatment of dental nickel hypersensitivity.
Collapse
Affiliation(s)
- Ezgi Eren Belgin
- Faculty of Science, Muğla Sıtkı Koçman University, Muğla, 48000, Turkey
| | - Deniz Genç
- Research Laboratories Center, Muğla Sıtkı Koçman University, Muğla, 48000, Turkey
- Faculty of Health Sciences, Department of Pediatric Nursing, Muğla Sıtkı Koçman University, Muğla, 48000, Turkey
| | - Leyla Tekin
- Faculty of Medicine, Department of Pathology, Muğla Sıtkı Koçman University, Muğla, 48000, Turkey
| | - Serhat Sezgin
- Faculty of Dentistry, Muğla Sıtkı Koçman University, Muğla, 48000, Turkey
| | - Akın Aladağ
- Faculty of Dentistry, Muğla Sıtkı Koçman University, Muğla, 48000, Turkey
| |
Collapse
|
10
|
Lin ZH, Chang HC, Wu YL, Gau SY. Increased Risk of New-Onset Rheumatoid Arthritis Among Osteoarthritis Patients Received Total Knee Arthroplasty: a global federated health network analysis. Int J Med Sci 2024; 21:994-1002. [PMID: 38774753 PMCID: PMC11103392 DOI: 10.7150/ijms.93457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 03/28/2024] [Indexed: 05/24/2024] Open
Abstract
Background: Complications of total knee arthroplasty (TKA) had been widely discussed. However, whether TKA influence risk of rheumatoid arthritis (RA) in osteoarthritis patients remained uncertain. We intend to evaluate the risk of RA in osteoarthritis patients underwent TKA. Methods: In this retrospective cohort study, data was retrieved from the US collaborative networks in TriNetX research network. Within the study period between 2005 and 2017, osteoarthritis patients underwent TKA were enrolled as case cohort whereas osteoarthritis patients never underwent TKA were enrolled as control cohort. Covariates were matched via propensity score matching. Risk of RA in TKA patients were valuated under various follow-up time and sensitivity models. Results: Under 1-year, 3-year and 5-year of follow-up, TKA patients were associated with significantly elevated risk of RA, especially under 1-year follow-up (HR=1.74; 95% CI, 1.39-2.18). Subgroup analysis demonstrated a significant increase in the risk of RA following TKA in the female subgroup (HR=1.42; 95% CI, 1.24-1.63), the subgroup aged 18-64 years (HR=1.48; 95% CI, 1.11-1.97), and the subgroup aged greater than 65 years old (HR=1.38; 95% CI, 1.21-1.58) based on 5-year follow-up. Conclusion: Clinicians should be concerned about uncharted association between TKA and RA reported our current study. Additional prospective studies and in-depth mechanistic inquiries were warranted to determine the causation.
Collapse
Affiliation(s)
- Zong-Han Lin
- Department of Medical Education and Research, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan
| | - Hui-Chin Chang
- Evidence-based Medicine Center, Chung Shan Medical University Hospital, Taichung, Taiwan
- Library, Chung Shan Medical University Hospital, Taichung, Taiwan
- School of Medicine, Chung Shan Medical University, Taichung, Taiwan
| | - Yu-Lun Wu
- Department of Neurosurgery, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan
- School of Medicine, College of Medicine, National Sun Yat-sen University, Kaohsiung, Taiwan
| | - Shuo-Yan Gau
- School of Medicine, Chung Shan Medical University, Taichung, Taiwan
- Department of Medical Education, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, Taiwan
- Orthopedics Department, Chi-Mei Medical Center, Tainan, Taiwan
| |
Collapse
|
11
|
Korbi M, Ouni N, Lahouel I, Machghoul S, Othmen Y, Belhadjali H, Zrig M, Koubaa M, Abid A, Henchi MA, Zili J. Contact Allergy to Methyl Methacrylate in Cemented Total Knee Arthroplasty: Challenging Diagnosis. Dermatitis 2023. [PMID: 38112522 DOI: 10.1089/derm.2022.29026.kmo] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2023]
Affiliation(s)
- Mouna Korbi
- From the Dermatology Department, Fattouma Bourguiba University Hospital, University of Monastir, Monastir, Tuniisia
- Research Laboratory LR20SP03A
| | - Nour Ouni
- From the Dermatology Department, Fattouma Bourguiba University Hospital, University of Monastir, Monastir, Tuniisia
| | - Ines Lahouel
- From the Dermatology Department, Fattouma Bourguiba University Hospital, University of Monastir, Monastir, Tuniisia
- Research Laboratory LR20SP03A
| | - Samia Machghoul
- Occupational Medicine Department, Fattouma Bourguiba University Hospital, University of Monastir, Monastir, Tuniisia
| | - Youssef Othmen
- Orthopedic Surgery Department, Fattouma Bourguiba University Hospital, University of Monastir, Monastir, Tuniisia
| | - Hichem Belhadjali
- From the Dermatology Department, Fattouma Bourguiba University Hospital, University of Monastir, Monastir, Tuniisia
- Research Laboratory LR20SP03A
| | - Makrem Zrig
- Orthopedic Surgery Department, Fattouma Bourguiba University Hospital, University of Monastir, Monastir, Tuniisia
| | - Moustapha Koubaa
- Orthopedic Surgery Department, Fattouma Bourguiba University Hospital, University of Monastir, Monastir, Tuniisia
| | - Abderrazek Abid
- Orthopedic Surgery Department, Fattouma Bourguiba University Hospital, University of Monastir, Monastir, Tuniisia
| | - Mohamed Adnène Henchi
- Occupational Medicine Department, Fattouma Bourguiba University Hospital, University of Monastir, Monastir, Tuniisia
| | - Jameleddine Zili
- From the Dermatology Department, Fattouma Bourguiba University Hospital, University of Monastir, Monastir, Tuniisia
- Research Laboratory LR20SP03A
| |
Collapse
|
12
|
Shabalina AV, Anikeev SG, Kulinich SA, Artyukhova NV, Vlasov VA, Kaftaranova MI, Hodorenko VN, Yakovlev EV, Pesterev EA, Lukyanenko AV, Volochaev MN, Pakholkina S, Mamazakirov O, Stolyarov VV, Mokshin AV, Gunther VE. Combined Porous-Monolithic TiNi Materials Surface-Modified with Electron Beam for New-Generation Rib Endoprostheses. J Funct Biomater 2023; 14:jfb14050277. [PMID: 37233387 DOI: 10.3390/jfb14050277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Revised: 05/06/2023] [Accepted: 05/10/2023] [Indexed: 05/27/2023] Open
Abstract
TiNi alloys are very widely used materials in implant fabrication. When applied in rib replacement, they are required to be manufactured as combined porous-monolithic structures, ideally with a thin, porous part well-adhered to its monolithic substrate. Additionally, good biocompatibility, high corrosion resistance and mechanical durability are also highly demanded. So far, all these parameters have not been achieved in one material, which is why an active search in the field is still underway. In the present study, we prepared new porous-monolithic TiNi materials by sintering a TiNi powder (0-100 µm) on monolithic TiNi plates, followed by surface modification with a high-current pulsed electron beam. The obtained materials were evaluated by a set of surface and phase analysis methods, after which their corrosion resistance and biocompatibility (hemolysis, cytotoxicity, and cell viability) were evaluated. Finally, cell growth tests were conducted. In comparison with flat TiNi monoliths, the newly developed materials were found to have better corrosion resistance, also demonstrating good biocompatibility and potential for cell growth on their surface. Thus, the newly developed porous-on-monolith TiNi materials with different surface porosity and morphology showed promise as potential new-generation implants for use in rib endoprostheses.
Collapse
Affiliation(s)
| | - Sergey G Anikeev
- Laboratory of Medical Materials Science, Tomsk State University, 634050 Tomsk, Russia
- Institute of Physics, Kazan Federal University, 420008 Kazan, Russia
| | - Sergei A Kulinich
- Research Institute of Science and Technology, Tokai University, Hiratsuka 259-1292, Kanagawa, Japan
| | - Nadezhda V Artyukhova
- Laboratory of Medical Materials Science, Tomsk State University, 634050 Tomsk, Russia
| | - Vitaly A Vlasov
- Research School of High-Energy Physics, National Research Tomsk Polytechnic University, 634050 Tomsk, Russia
| | - Maria I Kaftaranova
- Laboratory of Medical Materials Science, Tomsk State University, 634050 Tomsk, Russia
| | - Valentina N Hodorenko
- Laboratory of Medical Materials Science, Tomsk State University, 634050 Tomsk, Russia
| | - Evgeny V Yakovlev
- Tomsk Scientific Center, Siberian Branch of Russian Academy of Sciences, 634055 Tomsk, Russia
| | - Evgeny A Pesterev
- Tomsk Scientific Center, Siberian Branch of Russian Academy of Sciences, 634055 Tomsk, Russia
| | - Anna V Lukyanenko
- Kirensky Institute of Physics, Federal Research Center, KSC Siberian Branch Russian Academy of Science, 660036 Krasnoyarsk, Russia
- School of Engineering Physics and Radio Electronics, Siberian Federal University, 660041 Krasnoyarsk, Russia
| | - Mikhail N Volochaev
- Kirensky Institute of Physics, Federal Research Center, KSC Siberian Branch Russian Academy of Science, 660036 Krasnoyarsk, Russia
| | - Sofiya Pakholkina
- Laboratory of Medical Materials Science, Tomsk State University, 634050 Tomsk, Russia
| | - Oibek Mamazakirov
- Laboratory of Medical Materials Science, Tomsk State University, 634050 Tomsk, Russia
| | - Victor V Stolyarov
- Department of Morphology and Physiology of the Medical Institute, Surgut State University, 628403 Surgut, Russia
| | | | - Victor E Gunther
- Laboratory of Medical Materials Science, Tomsk State University, 634050 Tomsk, Russia
| |
Collapse
|
13
|
Jang SR, Suh IW, Heng L. Nanoscale Polishing Technique of Biomedical Grade NiTi Wire by Advanced MAF Process: Relationship between Surface Roughness and Bacterial Adhesion. J Funct Biomater 2023; 14:177. [PMID: 37103267 PMCID: PMC10143815 DOI: 10.3390/jfb14040177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Revised: 03/22/2023] [Accepted: 03/22/2023] [Indexed: 04/28/2023] Open
Abstract
Nitinol (NiTi), an alloy of nickel and titanium, wires are an important biomedical material that has been used in catheter tubes, guidewires, stents, and other surgical instruments. As such wires are temporarily or permanently inserted inside the human body, their surfaces need to be smoothed and cleaned in order to prevent wear, friction, and adhesion of bacteria. In this study, NiTi wire samples of micro-scale diameters (i.e., Ø 200 μm and Ø 400 μm) were polished by an advanced magnetic abrasive finishing (MAF) process using a nanoscale polishing method. Furthermore, bacterial adhesion (i.e., Escherichia coli (E. coli), and Staphylococcus aureus (S. aureus)) to the initial and final surfaces of NiTi wires were investigated and compared in order to assess the impact of surface roughness on bacterial adhesion to the surfaces of NiTi wires. The finding revealed that the surfaces of NiTi wires were clean and smooth with a lack of particle impurities and toxic components on the final surface polished using the advanced MAF process. The surface roughness Ra values of the Ø 200 μm and Ø 400 μm NiTi wires were smoothly enhanced to 20 nm and 30 nm from the 140 nm and 280 nm initial surface roughness values. Importantly, polishing the surfaces of a biomedical material such as NiTi wire to nano-level roughness can significantly reduce bacterial adhesion on the surface by more than 83.48% in the case of S. aureus, while in the case of E. coli was more than 70.67%.
Collapse
Affiliation(s)
- Se Rim Jang
- Division of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, 567, Baekje-daero, Jeonju-si 54896, Republic of Korea;
| | - Il Won Suh
- Department of Bionanotechnology and Bioconvergence Engineering, Graduate School, Jeonbuk National University, Jeonju 561-656, Republic of Korea;
| | - Lida Heng
- Division of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, 567, Baekje-daero, Jeonju-si 54896, Republic of Korea;
| |
Collapse
|
14
|
Chang CH, Wu RW. Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy. Tzu Chi Med J 2023. [DOI: 10.4103/tcmj.tcmj_255_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023] Open
|
15
|
Anastasio AT, Johnson LG, Willhite JP, Mousallem T, Hendershot EF, Parekh SG. Team Approach: Metal Hypersensitivity in Total Joint Arthroplasty. JBJS Rev 2023; 11:01874474-202301000-00002. [PMID: 36722837 DOI: 10.2106/jbjs.rvw.22.00157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
» As total joint arthroplasty volume continues to grow nationwide, more uncommon complications such as metal implant hypersensitivity are reported with greater frequency in the literature. » Metal hypersensitivity is a challenging diagnosis given the potentially vague symptomology. It should be considered a diagnosis of exclusion, necessitating careful consideration of other potential etiologies of a failing implant before arriving at the final diagnosis of metal hypersensitivity. » Patients can experience substantial morbidity from implant rejection and in severe, refractory cases may even require revision arthroplasty and conversion to a hypoallergenic implant. » Given the complex nature of the condition, successful treatment of metal hypersensitivity to orthopaedic implants is best achieved through the use of a multidisciplinary, team-based approach. Immunologists, radiologists, and infectious disease physicians as well as orthopaedic surgeons and mechanical engineers are all vital in appropriate diagnosis and treatment of the condition.
Collapse
Affiliation(s)
| | - Lindsey G Johnson
- Campbell University School of Osteopathic Medicine, Lillington, North Carolina
| | | | | | | | | |
Collapse
|
16
|
Aoyama R, Anazawa U, Hotta H, Watanabe I, Takahashi Y, Matsumoto S. Cervical Implant Allergy With Chronic Neck Pain: A Case Report. Cureus 2022; 14:e28293. [PMID: 36158409 PMCID: PMC9494577 DOI: 10.7759/cureus.28293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/23/2022] [Indexed: 11/21/2022] Open
Abstract
A 57-year-old woman underwent cervical implant surgery for a dislocated cervical spine fracture, and she complained of continuous intractable neck pain after surgery. Eight years later, she developed a plantar skin rash, subsequently diagnosed as a metal allergy, and metal dentures were replaced with ceramic ones. The skin rash, however, persisted for four more years after that and was eventually treated with cervical implant removal. Subsequently, her skin rash and her neck pain improved simultaneously. This synchronous improvement strongly suggested that the neck pain could have been caused by a cervical implant allergy. We discuss a case of posterior cervical implant allergy that presented with neck pain and plantar skin rash years after surgery.
Collapse
|
17
|
Involvement of NF-κB/NLRP3 axis in the progression of aseptic loosening of total joint arthroplasties: a review of molecular mechanisms. Naunyn Schmiedebergs Arch Pharmacol 2022; 395:757-767. [PMID: 35377011 DOI: 10.1007/s00210-022-02232-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Accepted: 03/11/2022] [Indexed: 10/18/2022]
Abstract
Particulate wear debris can trigger pro-inflammatory bone resorption and result in aseptic loosening. This complication remains major postoperative discomforts and complications for patients who underwent total joint arthroplasty. Recent studies have indicated that wear debris-induced aseptic loosening is associated with the overproduction of pro-inflammatory cytokines. The activation of osteoclasts as a result of inflammatory responses is associated with osteolysis. Moreover, stimulation of inflammatory signaling pathways such as the NF-κB/NLRP3 axis results in the production of pro-inflammatory cytokines. In this review, we first summarized the potential inflammatory mechanisms of wear particle-induced peri-implant osteolysis. Then, the therapeutic approaches, e.g., biological inhibitors, herbal products, and stem cells or their derivatives, with the ability to suppress the inflammatory responses, mainly NF-κB/NLRP3 signaling pathways, were discussed. Based on the results, activation of macrophages following inflammatory stimuli, overproduction of pro-inflammatory cytokines, and subsequent differentiation of osteoclasts in the presence of wear particles lead to bone resorption. The activation of NF-κB/NLRP3 signaling pathways within the macrophages stimulates the production of pro-inflammatory cytokines, e.g., IL-1β, IL-6, and TNF-α. According to in vitro and in vivo studies, novel therapeutics significantly promoted osteogenesis, suppressed osteoclastogenesis, and diminished particle-mediated bone resorption. Conclusively, these findings offer that suppressing pro-inflammatory cytokines by regulating both NF-κB and NLRP3 inflammasome represents a novel approach to attenuate wear-particle-related osteolytic diseases.
Collapse
|
18
|
Schoon J, Hesse B, Tucoulou R, Geissler S, Ort M, Duda GN, Perka C, Wassilew GI, Perino G, Rakow A. Synchrotron-based characterization of arthroprosthetic CoCrMo particles in human bone marrow. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2022; 33:54. [PMID: 35691951 PMCID: PMC9189090 DOI: 10.1007/s10856-022-06675-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Accepted: 05/18/2022] [Indexed: 06/15/2023]
Abstract
Particles released from cobalt-chromium-molybdenum (CoCrMo) alloys are considered common elicitors of chronic inflammatory adverse effects. There is a lack of data demonstrating particle numbers, size distribution and elemental composition of bone marrow resident particles which would allow for implementation of clinically relevant test strategies in bone marrow models at different degrees of exposure. The aim of this study was to investigate metal particle exposure in human periprosthetic bone marrow of three types of arthroplasty implants. Periprosthetic bone marrow sections from eight patients exposed to CoCrMo particles were analyzed via spatially resolved and synchrotron-based nanoscopic X-ray fluorescence imaging. These analyses revealed lognormal particle size distribution patterns predominantly towards the nanoscale. Analyses of particle numbers and normalization to bone marrow volume and bone marrow cell number indicated particle concentrations of up to 1 × 1011 particles/ml bone marrow or 2 × 104 particles/bone marrow cell, respectively. Analyses of elemental ratios of CoCrMo particles showed that particularly the particles' Co content depends on particle size. The obtained data point towards Co release from arthroprosthetic particles in the course of dealloying and degradation processes of larger particles within periprosthetic bone marrow. This is the first study providing data based on metal particle analyses to be used for future in vitro and in vivo studies of possible toxic effects in human bone marrow following exposure to arthroprosthetic CoCrMo particles of different concentration, size, and elemental composition. Graphical abstract.
Collapse
Affiliation(s)
- Janosch Schoon
- Center for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, 17475, Greifswald, Germany.
- Julius Wolff Institute, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.
| | - Bernhard Hesse
- Xploraytion GmbH, 10625, Berlin, Germany.
- ESRF-The European Synchrotron, 38000, Grenoble, France.
| | - Remi Tucoulou
- ESRF-The European Synchrotron, 38000, Grenoble, France
| | - Sven Geissler
- BIH Center for Regenerative Therapies (BCRT), Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Melanie Ort
- Julius Wolff Institute, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
- BIH Center for Regenerative Therapies (BCRT), Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Georg N Duda
- Julius Wolff Institute, Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Carsten Perka
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Georgi I Wassilew
- Center for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, 17475, Greifswald, Germany
| | - Giorgio Perino
- Center for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, 17475, Greifswald, Germany
| | - Anastasia Rakow
- Center for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, 17475, Greifswald, Germany
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| |
Collapse
|
19
|
Metallic Implants Used in Lumbar Interbody Fusion. MATERIALS 2022; 15:ma15103650. [PMID: 35629676 PMCID: PMC9146470 DOI: 10.3390/ma15103650] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 05/12/2022] [Accepted: 05/13/2022] [Indexed: 02/07/2023]
Abstract
Over the last decade, pedicle fixation systems have evolved and modifications in spinal fusion techniques have been developed to increase fusion rates and improve clinical outcomes after lumbar interbody fusion (LIF). Regarding materials used for screw and rod manufacturing, metals, especially titanium alloys, are the most popular resources. In the case of pedicle screws, that biomaterial can be also doped with hydroxyapatite, CaP, ECM, or tantalum. Other materials used for rod fabrication include cobalt-chromium alloys and nitinol (nickel-titanium alloy). In terms of mechanical properties, the ideal implant used in LIF should have high tensile and fatigue strength, Young's modulus similar to that of the bone, and should be 100% resistant to corrosion to avoid mechanical failures. On the other hand, a comprehensive understanding of cellular and molecular pathways is essential to identify preferable characteristics of implanted biomaterial to obtain fusion and avoid implant loosening. Implanted material elicits a biological response driven by immune cells at the site of insertion. These reactions are subdivided into innate (primary cellular response with no previous exposure) and adaptive (a specific type of reaction induced after earlier exposure to the antigen) and are responsible for wound healing, fusion, and also adverse reactions, i.e., hypersensitivity. The main purposes of this literature review are to summarize the physical and mechanical properties of metal alloys used for spinal instrumentation in LIF which include fatigue strength, Young's modulus, and corrosion resistance. Moreover, we also focused on describing biological response after their implantation into the human body. Our review paper is mainly focused on titanium, cobalt-chromium, nickel-titanium (nitinol), and stainless steel alloys.
Collapse
|
20
|
Suh LJ, Khan I, Kelley-Patteson C, Mohan G, Hassanein AH, Sinha M. Breast Implant-Associated Immunological Disorders. J Immunol Res 2022; 2022:8536149. [PMID: 35571560 PMCID: PMC9095406 DOI: 10.1155/2022/8536149] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 04/05/2022] [Accepted: 04/16/2022] [Indexed: 11/18/2022] Open
Abstract
Background Breast implants are commonly placed postbreast cancer reconstruction, cosmetic augmentation, and gender-affirming surgery. Breast implant illness (BII) is a systemic complication associated with breast implants. Patients with BII may experience autoimmune symptoms including fatigue, difficulty concentrating, hair loss, weight change, and depression. BII is poorly understood, and the etiology is unknown. The purpose of this literature review is to characterize BII autoimmune disorders and determine possible causes for its etiology. Methods The PubMed, Google Scholar, Embase, Web of Science, and OVID databases were interrogated from 2010 to 2020 using a query strategy including search term combinations of "implants," "breast implant illness," "autoimmune," and "systemic illness." Results BII includes a spectrum of autoimmune symptoms such as fatigue, myalgias/arthralgias, dry eyes/mouth, and rash. A review of epidemiological studies in the past ten years exhibited evidence affirming an association between breast implants and autoimmune diseases. The most commonly recognized were Sjogren's syndrome, rheumatoid arthritis, systemic sclerosis, chronic fatigue syndrome, and Raynaud's syndrome. Explantation resulted in alleviation of symptoms in over 50% of patients, strengthening the hypothesis linking breast implants to BII. Studies have shown that silicone is a biologically inert material and unlikely to be the cause of these symptoms. This is supported by the fact that increased risk of autoimmune disease was also reported in patients with other implantable biomaterials such as orthopedic implants. Recent studies shed light on a possible role of bacterial biofilm and subsequent host-pathogen interactions as a confounding factor to this problem. Conclusion BII could be dependent on biofilm infection and the microenvironment around the implants. The true pathophysiology behind these complaints must be further investigated so that alternative treatment regimens other than explantation can be developed. Translational significance of these studies is not limited to breast implants but extends to other implants as well.
Collapse
Affiliation(s)
- Lily J. Suh
- Department of Surgery, Indiana Center for Regenerative Medicine and Engineering, Indiana University School of Medicine, Indianapolis, IN 46202, USA
| | - Imran Khan
- Department of Surgery, Indiana Center for Regenerative Medicine and Engineering, Indiana University School of Medicine, Indianapolis, IN 46202, USA
| | | | - Ganesh Mohan
- Department of Surgery, Indiana Center for Regenerative Medicine and Engineering, Indiana University School of Medicine, Indianapolis, IN 46202, USA
| | - Aladdin H. Hassanein
- Department of Surgery, Indiana Center for Regenerative Medicine and Engineering, Indiana University School of Medicine, Indianapolis, IN 46202, USA
| | - Mithun Sinha
- Department of Surgery, Indiana Center for Regenerative Medicine and Engineering, Indiana University School of Medicine, Indianapolis, IN 46202, USA
| |
Collapse
|
21
|
Battaglia AG, Ali-Zade C, Monti L, Al Khawashki H, Winkler H, Del Sel H, Mavrogenis AF, Benzakour T, Drago L, Romanò CL. Metal Hypersensitivity or Missed Periprosthetic Joint Infection? A Critical Review. Orthopedics 2022; 45:e73-e78. [PMID: 34978510 DOI: 10.3928/01477447-20211227-04] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The World Association Against Infection in Orthopedics And Trauma (W.A.I.O.T.) Study Group on Bone And Joint Infection Definitions Metal hypersensitivity (MHS) has been investigated by several authors as a possible reason for painful total joint arthroplasty, with controversial results. Periprosthetic joint infection (PJI) is another possible source of unexplained pain and implant failure that may be difficult to diagnose if not properly investigated. We performed this critical review to assess whether the current literature on MHS includes an adequate diagnostic workup to discern metal allergy from PJI. The results of this review highlight the importance of assessing patients for PJI before making a diagnosis of MHS and emphasize that the methods currently used to exclude PJI are substantially inadequate. Therefore, well-designed clinical trials with adequate diagnostic protocols and definitions of PJI that can differentiate MHS from low-grade PJI are needed. [Orthopedics. 2022;45(2):e73-e78.].
Collapse
|
22
|
Shields LB, Vessell M, Mutchnick IS. Epidural Effusion as Allergic Reaction Following Polyetheretherketone Cranioplasty: An Illustrative Case and Review of the Literature. Cureus 2022; 14:e21390. [PMID: 35198299 PMCID: PMC8853833 DOI: 10.7759/cureus.21390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/18/2022] [Indexed: 11/05/2022] Open
Abstract
Well-described complications of polyetheretherketone (PEEK) cranioplasty in pediatric patients include surgical site infection, post-operative hematoma, cerebral edema, and implant fracture. We present a rare case of hypersensitivity to PEEK presenting as an epidural effusion in a 7-year-old male receiving a PEEK cranioplasty following a decompressive craniectomy. Within three weeks, the patient experienced fever and emesis. Erythrocyte sedimentation rate (ESR) was high (>130 mm/Hr) as well as C-reactive protein (CRP) (6.4 mg/dL). A brain MRI with contrast demonstrated both subgaleal and epidural fluid collections with T2 isointense columns projecting from the galeal surface, through the holes in the implant to the dural surface. The patient appeared clinically well. A sterile tap of the pericranial fluid showed no growth, b2-transferrin was negative, but the IgG level was high (>129.2 mg/dL) in the tap fluid. High-dose steroids reduced the epidural collection, but then the collection returned with steroid wean. A second cranioplasty operation replaced the PEEK flap with autologous bone. Postoperative imaging demonstrated markedly reduced fluid collections and a decreased midline shift. The patient remained clinically intact throughout the experience. PEEK allergy following cranioplasty is a rare entity and must be distinguished from infection or hematoma. Medical treatment with steroids can be attempted, but, if refractory, then appropriate treatment may necessitate removal of the offending PEEK implant.
Collapse
|
23
|
Abstract
Regenerative engineering has pioneered several novel biomaterials to treat critical-sized bone injuries. However, despite significant improvement in synthetic materials research, some limitations still exist. The constraints correlated with the current grafting methods signify a treatment paradigm shift to osteoinductive regenerative engineering approaches. Because of their intrinsic potential, inductive biomaterials may represent alternative approaches to treating critical bone injuries. Osteoinductive scaffolds stimulate stem cell differentiation into the osteoblastic lineage, enhancing bone regeneration. Inductive biomaterials comprise polymers, calcium phosphate ceramics, metals, and graphene family materials. This review will assess the cellular behavior toward properties of inductive materials.
Collapse
Affiliation(s)
- F S Hosseini
- Connecticut Convergence Institute for Translation in Regenerative Engineering, University of Connecticut Health, Farmington, CT, USA
- Raymond and Beverly Sackler Center for Biological, Physical and Engineering Sciences, University of Connecticut Health, Farmington, CT, USA
- Department of Orthopedic Surgery, University of Connecticut Health, Farmington, CT, USA
- Department of Skeletal Biology and Regeneration, UConn Health, Farmington, CT, USA
| | - L S Nair
- Connecticut Convergence Institute for Translation in Regenerative Engineering, University of Connecticut Health, Farmington, CT, USA
- Raymond and Beverly Sackler Center for Biological, Physical and Engineering Sciences, University of Connecticut Health, Farmington, CT, USA
- Department of Orthopedic Surgery, University of Connecticut Health, Farmington, CT, USA
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
- Department of Materials Science and Engineering, University of Connecticut, Storrs, CT, USA
| | - C T Laurencin
- Connecticut Convergence Institute for Translation in Regenerative Engineering, University of Connecticut Health, Farmington, CT, USA
- Raymond and Beverly Sackler Center for Biological, Physical and Engineering Sciences, University of Connecticut Health, Farmington, CT, USA
- Department of Orthopedic Surgery, University of Connecticut Health, Farmington, CT, USA
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
- Department of Materials Science and Engineering, University of Connecticut, Storrs, CT, USA
- Department of Chemical and Biomolecular Engineering, University of Connecticut, Storrs, CT, USA
| |
Collapse
|
24
|
Titanium and Other Metal Hypersensitivity Diagnosed by MELISA® Test: Follow-Up Study. BIOMED RESEARCH INTERNATIONAL 2021; 2021:5512091. [PMID: 34124241 PMCID: PMC8192180 DOI: 10.1155/2021/5512091] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 05/07/2021] [Accepted: 05/20/2021] [Indexed: 11/22/2022]
Abstract
This study is aimed at proving the clinical benefit of the MELISA® test in the minimization or complete elimination of health problems in patients with confirmed hypersensitivity to metals used for tissue replacements. A group of 305 patients aged 20-75 years with previously proven metal hypersensitivity (initial MELISA® test), mainly to titanium and then to another fifteen metals, was chosen from the database at the Institute of Dental Medicine. From these patients, a final group of 42 patients agreed to participate in the study, 35 of which were female and 7 were male. The patients completed a special questionnaire aimed at information regarding change of health status from their last visit and determining whether the results of the initial MELISA® test and recommendations based on it were beneficial for patients or not. They were clinically examined, and peripheral blood samples were taken to perform follow-up MELISA® tests. Questionnaire data was processed, and the follow-up MELISA® test results were compared with the results of the initial MELISA® tests. For statistical analysis, the Fisher's exact test and paired T-test were used. Thirty-two patients reported that they followed the recommendations based on the results of the initial MELISA® tests, and of these, 30 patients (94%) confirmed significant health improvement. Six patients did not follow the recommendation, and from these, only one patient reported an improvement in his health problems. By comparison of the initial and follow-up MELISA® test results, it can be stated that the hypersensitivity to the given metal decreased or disappeared after the therapeutic interventions performed based on the initial MELISA® test results. The evaluation of the data obtained from patients in this study confirmed a significant clinical benefit of MELISA® test.
Collapse
|
25
|
Chung L, Maestas DR, Lebid A, Mageau A, Rosson GD, Wu X, Wolf MT, Tam AJ, Vanderzee I, Wang X, Andorko JI, Zhang H, Narain R, Sadtler K, Fan H, Čiháková D, Le Saux CJ, Housseau F, Pardoll DM, Elisseeff JH. Interleukin 17 and senescent cells regulate the foreign body response to synthetic material implants in mice and humans. Sci Transl Med 2021; 12:12/539/eaax3799. [PMID: 32295900 DOI: 10.1126/scitranslmed.aax3799] [Citation(s) in RCA: 88] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Accepted: 11/12/2019] [Indexed: 12/11/2022]
Abstract
Medical devices and implants made of synthetic materials can induce an immune-mediated process when implanted in the body called the foreign body response, which results in formation of a fibrous capsule around the implant. To explore the immune and stromal connections underpinning the foreign body response, we analyzed fibrotic capsules surrounding surgically excised human breast implants from 12 individuals. We found increased numbers of interleukin 17 (IL17)-producing γδ+ T cells and CD4+ T helper 17 (TH17) cells as well as senescent stromal cells in the fibrotic capsules. Further analysis in a murine model demonstrated an early innate IL17 response to implanted synthetic material (polycaprolactone) particles that was mediated by innate lymphoid cells and γδ+ T cells. This was followed by a chronic adaptive CD4+ TH17 cell response that was antigen dependent. Synthetic materials with varying chemical and physical properties implanted either in injured muscle or subcutaneously induced similar IL17 responses in mice. Mice deficient in IL17 signaling established that IL17 was required for the fibrotic response to implanted synthetic materials and the development of p16INK4a senescent cells. IL6 produced by senescent cells was sufficient for the induction of IL17 expression in T cells. Treatment with a senolytic agent (navitoclax) that killed senescent cells reduced IL17 expression and fibrosis in the mouse implant model. Discovery of a feed-forward loop between the TH17 immune response and the senescence response to implanted synthetic materials introduces new targets for therapeutic intervention in the foreign body response.
Collapse
Affiliation(s)
- Liam Chung
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA.,Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - David R Maestas
- Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Andriana Lebid
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Ashlie Mageau
- Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Gedge D Rosson
- Division of Plastic Surgery, Department of Surgery, Johns Hopkins University, Baltimore, MD, USA
| | - Xinqun Wu
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Matthew T Wolf
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA.,Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Ada J Tam
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Isabel Vanderzee
- Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Xiaokun Wang
- Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - James I Andorko
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA.,Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Hong Zhang
- Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Radhika Narain
- Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Kaitlyn Sadtler
- Section on Immuno-Engineering, National Institute for Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD, USA
| | - Hongni Fan
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Daniela Čiháková
- Department of Pathology, Johns Hopkins University, Baltimore, MD, USA
| | | | - Franck Housseau
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Drew M Pardoll
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Jennifer H Elisseeff
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA. .,Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| |
Collapse
|
26
|
Atomic Layer Deposition of aTiO2 Layer on Nitinol and Its Corrosion Resistance in a Simulated Body Fluid. METALS 2021. [DOI: 10.3390/met11040659] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Nitinol is a group of nearly equiatomic alloys composed of nickel and titanium, which was developed in the 1970s. Its properties, such as superelasticity and Shape Memory Effect, have enabled its use, especially for biomedical purposes. Due to the fact that Nitinol exhibits good corrosion resistance in a chloride environment, an unusual combination of strength and ductility, a high tendency for self-passivation, high fatigue strength, low Young’s modulus and excellent biocompatibility, its use is still increasing. In this research, Atomic Layer Deposition (ALD) experiments were performed on a continuous vertical cast (CVC) NiTi rod (made in-house) and on commercial Nitinol as the control material, which was already in the rolled state. The ALD deposition of the TiO2 layer was accomplished in a Beneq TFS 200 system at 250 °C. The pulsing times for TiCl4 and H2O were 250 ms and 180 ms, followed by appropriate purge cycles with nitrogen (3 s after the TiCl4 and 2 s after the H2O pulses). After 1100 repeated cycles of ALD depositing, the average thickness of the TiO2 layer for the CVC NiTi rod was 52.2 nm and for the commercial Nitinol, it was 51.7 nm, which was confirmed by X-ray Photoelectron Spectroscopy (XPS) and Scanning Electron Microscope (SEM) using Energy-dispersive X-ray (EDX) spectroscopy. The behaviour of the CVC NiTi and commercial Nitinol with and without the TiO2 layer was investigated in a simulated body fluid at body temperature (37 °C) to explain their corrosion resistance. Potentiodynamic polarisation measurements showed that the lowest corrosion current density (0.16 μA/cm2) and the wider passive region were achieved by the commercial NiTi with TiO2. Electrochemical Impedance Spectroscopy measurements revealed that the CVC NiTi rod and the commercial Nitinol have, for the first 48 h of immersion, only resistance through the oxide layer, as a consequence of the thin and compact layer. On the other hand, the TiO2/CVC NiTi rod and TiO2/commercial Nitinol had resistances through the oxide and porous layers the entire immersion time since the TiO2 layer was formatted on the surfaces.
Collapse
|
27
|
Dan CP, Dan SI, Silaşi AAD, Tomoaia G. Immunologic reactions to bone and articular implants. INTERNATIONAL ORTHOPAEDICS 2021; 45:1941-1946. [PMID: 33797580 DOI: 10.1007/s00264-021-04977-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 01/16/2021] [Accepted: 02/02/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND In recent years the number on implantable devices that have been used in orthopedic surgeries has increased exponentially. As the number of people with orthopedic implants has grown, implant failure has become an increasingly important public health issue. While a significant percent of joint implants fails at between 15 and 20 years some authors suggest that one of the main causes is the interaction between the immune system of the host and the material of the implant METHODS: The search engines used for research comprised of PubMed, Google Scholar and Cochrane Library. RESULTS This review aims to summarize relevant and recent data on the immune reactions that are taking place at the juxtaposition between the implant and the patient's tissue, the time frame in which these immune reactions take place and some of the factors that can influence this reaction. The immune reactions can be divided into: hyperacute immune reactions (anaphylactic shock), acute reactions, the transition between the acute phase and the chronic phase and last but not least chronic immune reactions to such implants. CONCLUSION The research being done with regard to implant-related immunology strives to help in solving the problem of long-term implant failure.
Collapse
Affiliation(s)
- Cristian Paul Dan
- Department of Orthopedics and Traumatology, Iuliu Hatieganu University of Medicine and Pharmacy, 47 Gen. Traian Mosoiu Street, 400132, Cluj-Napoca, Romania.
| | - Simona Irina Dan
- Department of Physical Medicine and Rehabilitation, Clinical Recovery Hospital Cluj-Napoca, Strada Viilor nr 46-50, Cluj Napoca, 400437, Romania
| | - Adrian Alexandru Dorin Silaşi
- Department of Medical Oncology, The Oncology Institute Prof. Dr. Ion Chiricuţă Cluj-Napoca, 34-36 Republicii Street, 400015, Cluj-Napoca, Romania
| | - Gheorghe Tomoaia
- Department of Orthopedics and Traumatology, Iuliu Hatieganu University of Medicine and Pharmacy, 47 Gen. Traian Mosoiu Street, 400132, Cluj-Napoca, Romania.,Academy of Romanian Scientists, Splaiul Independenţei, nr. 54, Bucharest, Romania
| |
Collapse
|
28
|
Wu K, Li B, Guo JJ. Fatigue Crack Growth and Fracture of Internal Fixation Materials in In Vivo Environments-A Review. MATERIALS (BASEL, SWITZERLAND) 2021; 14:E176. [PMID: 33401437 PMCID: PMC7795221 DOI: 10.3390/ma14010176] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 12/22/2020] [Accepted: 12/28/2020] [Indexed: 11/17/2022]
Abstract
The development of crack patterns is a serious problem affecting the durability of orthopedic implants and the prognosis of patients. This issue has gained considerable attention in the medical community in recent years. This literature focuses on the five primary aspects relevant to the evaluation of the surface cracking patterns, i.e., inappropriate use, design flaws, inconsistent elastic modulus, allergic reaction, poor compatibility, and anti-corrosiveness. The hope is that increased understanding will open doors to optimize fabrication for biomedical applications. The latest technological issues and potential capabilities of implants that combine absorbable materials and shape memory alloys are also discussed. This article will act as a roadmap to be employed in the realm of orthopedic. Fatigue crack growth and the challenges associated with materials must be recognized to help make new implant technologies viable for wider clinical adoption. This review presents a summary of recent findings on the fatigue mechanisms and fracture of implant in the initial period after surgery. We propose solutions to common problems. The recognition of essential complications and technical problems related to various approaches and material choices while satisfying clinical requirements is crucial. Additional investigation will be needed to surmount these challenges and reduce the likelihood of fatigue crack growth after implantation.
Collapse
Affiliation(s)
- Kailun Wu
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou 215000, China; (K.W.); (B.L.)
- Department of Orthopedics, Suzhou Dushuhu Public Hospital (Dushuhu Public Hospital Affiliated to Soochow University), Suzhou 215000, China
| | - Bin Li
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou 215000, China; (K.W.); (B.L.)
- Orthopedic Research Unit, Soochow University, Suzhou 215006, China
| | - Jiong Jiong Guo
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou 215000, China; (K.W.); (B.L.)
| |
Collapse
|
29
|
De Cuyper C. Tattoo allergy. Can we identify the allergen? Presse Med 2020; 49:104047. [DOI: 10.1016/j.lpm.2020.104047] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2018] [Accepted: 07/28/2020] [Indexed: 01/28/2023] Open
|
30
|
Malahias MA, Bauer TW, Gu A, Nocon AA, De Martino I, Sculco PK. Questioning the Clinical Relevance of Positive Post-implantation Allergy Testing for Metal Hypersensitivity in Total Knee Arthroplasty: A Didactic Case Report. HSS J 2020; 16:485-489. [PMID: 33380984 PMCID: PMC7749884 DOI: 10.1007/s11420-019-09710-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Accepted: 07/02/2019] [Indexed: 02/07/2023]
Affiliation(s)
- Michael-Alexander Malahias
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, 535 E 70th St, New York, NY 10021 USA
| | - Thomas W. Bauer
- Department of Pathology and Laboratory Medicine, Hospital for Special Surgery, 535 East 70th St, New York, NY 10021 USA
| | - Alex Gu
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, 535 E 70th St, New York, NY 10021 USA
| | - Allina A. Nocon
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, 535 E 70th St, New York, NY 10021 USA
| | - Ivan De Martino
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, 535 E 70th St, New York, NY 10021 USA
| | - Peter K. Sculco
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, 535 E 70th St, New York, NY 10021 USA
| |
Collapse
|
31
|
Moore EM, Maestas DR, Comeau HY, Elisseeff JH. The Immune System and Its Contribution to Variability in Regenerative Medicine. TISSUE ENGINEERING PART B-REVIEWS 2020; 27:39-47. [PMID: 32635878 DOI: 10.1089/ten.teb.2019.0335] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
The immune system plays a critical role in directing tissue repair and regeneration outcomes. Tissue engineering technologies that are designed to promote new tissue growth will therefore be impacted by immune factors that are present in patients both locally at the site of intervention and systemically. The immune state of patients can be influenced by many factors, including infection, nutrition, and other disease comorbidities. As a result, the immune state is highly variable and may be a source of variability in tissue-engineered products in the clinic, which is not found in preclinical models. In this review, we will summarize key immune cells and evidence of their activity in tissue repair and potential in tissue engineering systems. We also discuss how clinical translation of tissue engineering strategies, in particular stem cells, helped elucidate the importance of the immune system. With increased understanding of the immune system's role in repair and tissue engineering systems, it will likely become a therapeutic target and component of future therapies.
Collapse
Affiliation(s)
- Erika M Moore
- Department of Materials Science and Engineering, University of Florida, Gainesville, Florida, USA
| | - David R Maestas
- Translational Tissue Engineering Center, Johns Hopkins University, Baltimore, Maryland, USA
| | - Hannah Y Comeau
- Translational Tissue Engineering Center, Johns Hopkins University, Baltimore, Maryland, USA
| | - Jennifer H Elisseeff
- Translational Tissue Engineering Center, Johns Hopkins University, Baltimore, Maryland, USA
| |
Collapse
|
32
|
Titanium-Nitride Coating Does Not Result in a Better Clinical Outcome Compared to Conventional Cobalt-Chromium Total Knee Arthroplasty after a Long-Term Follow-Up: A Propensity Score Matching Analysis. COATINGS 2020. [DOI: 10.3390/coatings10050442] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Background: The impact of titanium nitride (TiN) coating on implant components is controversial. TiN coating is proposed as having superior biomechanical properties compared to conventional cobalt-chromium (CoCr) alloy. This study compared long-term clinical data as well as meteoro-sensitivity in patients who underwent total knee arthroplasty (TKA), with either CoCr alloy or TiN coating. Methods: In this retrospective observational study, the clinically approved cemented “low contact stress” (LCS) TKA with conventional CoCr coating, was compared to un-cemented TiN-coated “advanced coated system” (ACS) TKA. Propensity score matching identified comparable patients based on their characteristics in a one-to-one ratio using the nearest-neighbor method. The final cohort comprised 260 knees in each cohort, with a mean follow-up of 10.1 ± 1.0 years for ACS patients and 14.9 ± 3.0 years for the LCS group. Physical examinations, meteoro-sensitivity, and knee scoring were assessed. Results: The clinical and functional Knee Society Score (KSS) (82.6 vs. 70.8; p < 0.001 and 61.9 vs. 71.1; p = 0.011), the postoperative Visual Analogue Scale (VAS) (2.9 vs. 1.4; p = 0.002), and the postoperative Tegner Score (2.6 vs. 2.2; p = 0.001) showed significant intergroup differences. The postoperative Western Ontario & McMaster Universities Osteoarthritis Index (WOMAC) was similar (79.9 vs. 81.3; p = 0.453) between groups. Meteoro-sensitivity of the artificial joint was significantly more prevalent in the ACS patient cohort (56% vs. 23%; p < 0.001). Conclusion: This study suggests that TiN coating does not provide improved clinical outcomes in this patient cohort after a long-term follow-up. Interestingly, sensitivity to weather changes were more correlated with un-cemented ACS implants.
Collapse
|
33
|
Eftekhary N, Shepard N, Wiznia D, Iorio R, Long WJ, Vigdorchik J. Metal Hypersensitivity in Total Joint Arthroplasty. JBJS Rev 2019; 6:e1. [PMID: 30516716 DOI: 10.2106/jbjs.rvw.17.00169] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- Nima Eftekhary
- Department of Orthopaedic Surgery, NYU Langone Orthopaedic Hospital, New York, NY
| | | | | | | | | | | |
Collapse
|
34
|
Ort MJ, Geissler S, Rakow A, Schoon J. The Allergic Bone Marrow? The Immuno-Capacity of the Human Bone Marrow in Context of Metal-Associated Hypersensitivity Reactions. Front Immunol 2019; 10:2232. [PMID: 31620137 PMCID: PMC6759684 DOI: 10.3389/fimmu.2019.02232] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Accepted: 09/03/2019] [Indexed: 12/11/2022] Open
Abstract
Arthroplasty ranks among the greatest achievements of surgical medicine, with total hip replacement termed “the operation of the century.” Despite its wide success, arthroplasty bears risks, such as local reactions to implant derived wear and corrosion products. Prevalence of allergies across Western society increases and along the number of reported hypersensitivity reactions to orthopedic implant materials. In this context the main focus is on delayed hypersensitivity (DTH). This mechanism is mainly attributed to T cells and an overreaction of the adaptive immune system. Arthroplasty implant materials are in direct contact with bone marrow (BM), which is discussed as a secondary lymphoid organ. However, the mechanisms of sensitization toward implant wear remain elusive. Nickel and cobalt ions can form haptens with native peptides to activate immune cell receptors and are therefore common T helper allergens in cutaneous DTH. The rising prevalence of metal-related allergy in the general population and evidence for the immune-modulating function of BM allow for the assumption hypersensitivity reactions could occur in peri-implant BM. There is evidence that pro-inflammatory factors released during DTH reactions enhance osteoclast activity and inhibit osteoblast function, an imbalance characteristic for osteolysis. Even though some mechanisms are understood, hypersensitivity has remained a diagnosis of exclusion. This review aims to summarize current views on the pathomechanism of DTH in arthroplasty with emphasis on BM and discusses recent advances and future directions for basic research and clinical diagnostics.
Collapse
Affiliation(s)
- Melanie J Ort
- Julius Wolff Institute, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany.,Berlin Institute of Health Center for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Berlin, Germany.,Berlin-Brandenburg School for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Sven Geissler
- Julius Wolff Institute, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany.,Berlin Institute of Health Center for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Berlin, Germany.,Berlin-Brandenburg School for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Anastasia Rakow
- Berlin Institute of Health Center for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Berlin, Germany.,Center for Musculoskeletal Surgery, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Janosch Schoon
- Julius Wolff Institute, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany.,Berlin Institute of Health Center for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Berlin, Germany.,Berlin-Brandenburg School for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität zu Berlin, Berlin, Germany
| |
Collapse
|
35
|
Jithpratuck W, Kays D, Sriaroon P. A mysterious rash around surgical wounds. Ann Allergy Asthma Immunol 2019; 124:106-107. [PMID: 31520773 DOI: 10.1016/j.anai.2019.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Revised: 09/02/2019] [Accepted: 09/05/2019] [Indexed: 10/26/2022]
Affiliation(s)
- Warit Jithpratuck
- Division of Allergy and Immunology, Department of Pediatrics, University of South Florida, St Petersburg, Florida
| | - David Kays
- Department of Surgery, Johns Hopkins All Children's Hospital, St Petersburg, Florida
| | - Panida Sriaroon
- Division of Allergy and Immunology, Department of Pediatrics, University of South Florida, St Petersburg, Florida.
| |
Collapse
|
36
|
Saccomanno MF, Sircana G, Masci G, Cazzato G, Florio M, Capasso L, Passiatore M, Autore G, Maccauro G, Pola E. Allergy in total knee replacement surgery: Is it a real problem? World J Orthop 2019; 10:63-70. [PMID: 30788223 PMCID: PMC6379738 DOI: 10.5312/wjo.v10.i2.63] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Revised: 12/26/2018] [Accepted: 01/06/2019] [Indexed: 02/06/2023] Open
Abstract
Total knee arthroplasty is a common procedure, with extremely good clinical results. Despite this success, it produces 20% unsatisfactory results. Among the causes of these failures is metal hypersensitivity. Metal sensitization is higher in patients with a knee arthroplasty than in the general population and is even higher in patients undergoing revision surgery. However, a clear correlation between metal sensitization and symptomatic knee after surgery has not been ascertained. Surely, patients with a clear history of metal allergy must be carefully examined through dermatological and laboratory testing before surgery. There is no globally accepted diagnostic algorithm or laboratory test to diagnose metal hypersensitivity or metal reactions. The patch test is the most common test to determine metal hypersensitivity, though presenting some limitations. Several laboratory assays have been developed, with a higher sensitivity compared to patch testing, yet their clinical availability is not widespread, due to high costs and technical complexity. Symptoms of a reaction to metal implants present across a wide spectrum, ranging from pain and cutaneous dermatitis to aseptic loosening of the arthroplasty. However, although cutaneous and systemic hypersensitivity reactions to metals have arisen, thereby increasing concern after joint arthroplasties, allergies against implant materials remain quite rare and not a well-known problem. The aim of the following paper is to provide an overview on diagnosis and management of metal hypersensitivity in patients who undergo a total knee arthroplasty in order clarify its real importance.
Collapse
Affiliation(s)
- Maristella F Saccomanno
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Giuseppe Sircana
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Giulia Masci
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Gianpiero Cazzato
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Michela Florio
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Luigi Capasso
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Marco Passiatore
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Giovanni Autore
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Giulio Maccauro
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| | - Enrico Pola
- Department of Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome 00168, Italy
| |
Collapse
|
37
|
Mödinger Y, Teixeira GQ, Neidlinger-Wilke C, Ignatius A. Role of the Complement System in the Response to Orthopedic Biomaterials. Int J Mol Sci 2018; 19:ijms19113367. [PMID: 30373272 PMCID: PMC6274916 DOI: 10.3390/ijms19113367] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Revised: 10/24/2018] [Accepted: 10/25/2018] [Indexed: 12/22/2022] Open
Abstract
Various synthetic biomaterials are used to replace lost or damaged bone tissue that, more or less successfully, osseointegrate into the bone environment. Almost all biomaterials used in orthopedic medicine activate the host-immune system to a certain degree. The complement system, which is a crucial arm of innate immunity, is rapidly activated by an implanted foreign material into the human body, and it is intensely studied regarding blood-contacting medical devices. In contrast, much less is known regarding the role of the complement system in response to implanted bone biomaterials. However, given the increasing knowledge of the complement regulation of bone homeostasis, regeneration, and inflammation, complement involvement in the immune response following biomaterial implantation into bone appears very likely. Moreover, bone cells can produce complement factors and are target cells of activated complement. Therefore, new bone formation or bone resorption around the implant area might be greatly influenced by the complement system. This review aims to summarize the current knowledge on biomaterial-mediated complement activation, with a focus on materials primarily used in orthopedic medicine. In addition, methods to modify the interactions between the complement system and bone biomaterials are discussed, which might favor osseointegration and improve the functionality of the device.
Collapse
Affiliation(s)
- Yvonne Mödinger
- Institute of Orthopedic Research and Biomechanics, Centre for Trauma Research Ulm (ZTF Ulm), University of Ulm, D-89081 Ulm, Germany.
| | - Graciosa Q Teixeira
- Institute of Orthopedic Research and Biomechanics, Centre for Trauma Research Ulm (ZTF Ulm), University of Ulm, D-89081 Ulm, Germany.
| | - Cornelia Neidlinger-Wilke
- Institute of Orthopedic Research and Biomechanics, Centre for Trauma Research Ulm (ZTF Ulm), University of Ulm, D-89081 Ulm, Germany.
| | - Anita Ignatius
- Institute of Orthopedic Research and Biomechanics, Centre for Trauma Research Ulm (ZTF Ulm), University of Ulm, D-89081 Ulm, Germany.
| |
Collapse
|
38
|
Ferko MA, Catelas I. Effects of metal ions on caspase-1 activation and interleukin-1β release in murine bone marrow-derived macrophages. PLoS One 2018; 13:e0199936. [PMID: 30138321 PMCID: PMC6107125 DOI: 10.1371/journal.pone.0199936] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Accepted: 06/15/2018] [Indexed: 02/07/2023] Open
Abstract
Ions released from metal implants have been associated with adverse tissue reactions and are therefore a major concern. Studies with macrophages have shown that cobalt, chromium, and nickel ions can activate the NLRP3 inflammasome, a multiprotein complex responsible for the activation of caspase-1 (a proteolytic enzyme converting pro-interleukin [IL]-1β to mature IL-1β). However, the mechanism(s) of inflammasome activation by metal ions remain largely unknown. The objectives of the present study were to determine if, in macrophages: 1. caspase-1 activation and IL-1β release induced by metal ions are oxidative stress-dependent; and 2. IL-1β release induced by metal ions is NF-κB signaling pathway-dependent. Lipopolysaccharide (LPS)-primed murine bone marrow-derived macrophages (BMDM) were exposed to Co2+ (6-48 ppm), Cr3+ (100-500 ppm), or Ni2+ (12-96 ppm), in the presence or absence of a caspase-1 inhibitor (Z-WEHD-FMK), an antioxidant (L-ascorbic acid [L-AA]), or an NF-κB inhibitor (JSH-23). Culture supernatants were analyzed for caspase-1 by western blotting and/or IL-1β release by ELISA. Immunoblotting revealed the presence of caspase-1 (p20 subunit) in supernatants of BMDM incubated with Cr3+, but not with Ni2+ or Co2+. When L-AA (2 mM) was present with Cr3+, the caspase-1 p20 subunit was undetectable and IL-1β release decreased down to the level of the negative control, thereby demonstrating that caspase-1 activation and IL-1β release induced by Cr3+ was oxidative stress-dependent. ELISA demonstrated that Cr3+ induced the highest release of IL-1β, while Co2+ had no or limited effects. In the presence of Ni2+, the addition of L-AA (2 mM) also decreased IL-1β release, below the level of the negative control, suggesting that IL-1β release induced by Ni2+ was also oxidative stress-dependent. Finally, when present during both priming with LPS and activation with Cr3+, JSH-23 blocked IL-1β release, demonstrating NF-κB involvement. Overall, this study showed that while both Cr3+ and Ni2+ may be inducing inflammasome activation, Cr3+ is likely a more potent activator, acting through oxidative stress and the NF-κB signaling pathway.
Collapse
Affiliation(s)
| | - Isabelle Catelas
- Department of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada
- Department of Surgery, University of Ottawa, Ottawa, Ontario, Canada
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, Ontario, Canada
| |
Collapse
|
39
|
Furrer S, Scherer Hofmeier K, Grize L, Bircher AJ. Metal hypersensitivity in patients with orthopaedic implant complications-A retrospective clinical study. Contact Dermatitis 2018; 79:91-98. [PMID: 29888396 DOI: 10.1111/cod.13032] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Revised: 04/15/2018] [Accepted: 04/19/2018] [Indexed: 12/29/2022]
Abstract
BACKGROUND Hypersensitivity to metals as a cause of implant-related complications has been a subject of controversy. Projections indicate an increase in the frequency of joint replacements of between 300% and 600% by the year 2030; therefore, this issue is of considerable interest. OBJECTIVE To evaluate sensitization to implant materials in patients with implant-related complications, to identify allergens, and to clarify whether hypersensitivity is a relevant cause. METHODS Patients with implant-related complications or a positive history of contact allergy and planned total joint replacements referred for allergological investigation between 2004 and 2017 were retrospectively analysed. RESULTS In total, 311 patients were included. A positive patch test reaction to a metal was seen in 64.4% of preoperative patients and in 54.6% of patients with implant-related complications. Common alloy metals such as cobalt, chromium and titanium gave positive reactions in up to 2.9% of patients with implant-related complications. None of the patients with skin changes had a positive patch test reaction to an implant metal. CONCLUSION Other factors, such as the type of replaced joint and mechanical stress, seem to be more relevant for implant-related complications. Sensitization to metals or other materials seems to rarely play a role, and is overestimated.
Collapse
Affiliation(s)
- Stefan Furrer
- Department of Dermatology, Allergy Unit, University Hospital, Basel, Switzerland
| | | | - Leticia Grize
- Swiss Tropical and Public Health Institute, Basel, Switzerland.,University of Basel, Basel, Switzerland
| | - Andreas J Bircher
- Department of Dermatology, Allergy Unit, University Hospital, Basel, Switzerland.,University of Basel, Basel, Switzerland
| |
Collapse
|
40
|
Vieyra H, Juárez E, López UF, Morales AG, Torres M. Cytotoxicity and biocompatibility of biomaterials based in polyhydroxybutyrate reinforced with cellulose nanowhiskers determined in human peripheral leukocytes. Biomed Mater 2018; 13:045011. [DOI: 10.1088/1748-605x/aaaaf4] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
41
|
Liu C, Carrera R, Flamini V, Kenny L, Cabahug-Zuckerman P, George BM, Hunter D, Liu B, Singh G, Leucht P, Mann KA, Helms JA, Castillo AB. Effects of mechanical loading on cortical defect repair using a novel mechanobiological model of bone healing. Bone 2018; 108:145-155. [PMID: 29305998 PMCID: PMC8262576 DOI: 10.1016/j.bone.2017.12.027] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2015] [Revised: 12/20/2017] [Accepted: 12/29/2017] [Indexed: 12/30/2022]
Abstract
Mechanical loading is an important aspect of post-surgical fracture care. The timing of load application relative to the injury event may differentially regulate repair depending on the stage of healing. Here, we used a novel mechanobiological model of cortical defect repair that offers several advantages including its technical simplicity and spatially confined repair program, making effects of both physical and biological interventions more easily assessed. Using this model, we showed that daily loading (5N peak load, 2Hz, 60 cycles, 4 consecutive days) during hematoma consolidation and inflammation disrupted the injury site and activated cartilage formation on the periosteal surface adjacent to the defect. We also showed that daily loading during the matrix deposition phase enhanced both bone and cartilage formation at the defect site, while loading during the remodeling phase resulted in an enlarged woven bone regenerate. All loading regimens resulted in abundant cellular proliferation throughout the regenerate and fibrous tissue formation directly above the defect demonstrating that all phases of cortical defect healing are sensitive to physical stimulation. Stress was concentrated at the edges of the defect during exogenous loading, and finite element (FE)-modeled longitudinal strain (εzz) values along the anterior and posterior borders of the defect (~2200με) was an order of magnitude larger than strain values on the proximal and distal borders (~50-100με). It is concluded that loading during the early stages of repair may impede stabilization of the injury site important for early bone matrix deposition, whereas loading while matrix deposition and remodeling are ongoing may enhance stabilization through the formation of additional cartilage and bone.
Collapse
Affiliation(s)
- Chao Liu
- Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, USA; Department of Orthopaedic Surgery, New York University Langone Health, NYU Langone Orthopedic Hospital, NY, USA; Department of Veterans Affairs New York Harbor Healthcare System, New York, NY, USA
| | - Robert Carrera
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Vittoria Flamini
- Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, USA
| | - Lena Kenny
- Department of Orthopaedic Surgery, New York University Langone Health, NYU Langone Orthopedic Hospital, NY, USA
| | - Pamela Cabahug-Zuckerman
- Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, USA; Department of Orthopaedic Surgery, New York University Langone Health, NYU Langone Orthopedic Hospital, NY, USA; Department of Veterans Affairs New York Harbor Healthcare System, New York, NY, USA
| | - Benson M George
- Department of Surgery, Division of Plastic Surgery, Stanford University, Stanford, CA, USA
| | - Daniel Hunter
- Department of Surgery, Division of Plastic Surgery, Stanford University, Stanford, CA, USA
| | - Bo Liu
- Department of Surgery, Division of Plastic Surgery, Stanford University, Stanford, CA, USA
| | - Gurpreet Singh
- Department of Surgery, Division of Plastic Surgery, Stanford University, Stanford, CA, USA
| | - Philipp Leucht
- Department of Orthopaedic Surgery, New York University Langone Health, NYU Langone Orthopedic Hospital, NY, USA; Department of Cell Biology, New York University, New York, NY, USA
| | - Kenneth A Mann
- Department of Orthopedic Surgery, SUNY Upstate Medical University, Syracuse, NY, USA
| | - Jill A Helms
- Department of Surgery, Division of Plastic Surgery, Stanford University, Stanford, CA, USA
| | - Alesha B Castillo
- Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, USA; Department of Orthopaedic Surgery, New York University Langone Health, NYU Langone Orthopedic Hospital, NY, USA; Department of Veterans Affairs New York Harbor Healthcare System, New York, NY, USA.
| |
Collapse
|
42
|
Granchi D, Savarino LM, Ciapetti G, Baldini N. Biological effects of metal degradation in hip arthroplasties. Crit Rev Toxicol 2017; 48:170-193. [PMID: 29130357 DOI: 10.1080/10408444.2017.1392927] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Metals and metal alloys are the most used materials in orthopedic implants. The focus is on total hip arthroplasty (THA) that, though well tolerated, may be associated with local and remote adverse effects in the medium-long term. This review aims to summarize data on the biological consequences of the metal implant degradation that have been attributed predominantly to metal-on-metal (MoM) THA. Local responses to metals consist of a broad clinical spectrum ranging from small asymptomatic tissue lesions to severe destruction of bone and soft tissues, which are designated as metallosis, adverse reactions to metal debris (ARMD), aseptic lymphocytic vasculitis associated lesion (ALVAL), and pseudotumors. In addition, the dissemination of metal particles and ions throughout the body has been associated with systemic adverse effects, including organ toxicity, cancerogenesis, teratogenicity, and immunotoxicity. As proved by the multitude of studies in this field, metal degradation may increase safety issues associated with THA, especially with MoM hip systems. Data collection regarding local, systemic and long-term effects plays an essential role to better define any safety risks and to generate scientifically based recommendations.
Collapse
Affiliation(s)
- Donatella Granchi
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Lucia Maria Savarino
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Gabriela Ciapetti
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Nicola Baldini
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy.,b Department of Biomedical and Neuromotor Science , University of Bologna , Bologna , Italy
| |
Collapse
|