1
|
Calik-Kutukcu E, Tekerlek H, Bozdemir-Ozel C, Karaduz BN, Cakmak A, Inal-Ince D, Saglam M, Vardar-Yagli N, Sonbahar-Ulu H, Firat M, Arikan H, Kaya SB, Karakaya G. Validity and reliability of 6-minute pegboard and ring test in patients with asthma. J Asthma 2021; 59:1387-1395. [PMID: 33985406 DOI: 10.1080/02770903.2021.1930040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
OBJECTIVE The 6-minute pegboard and ring test (6PBRT) is a test of upper-extremity functional capacity designed for and validated in chronic obstructive pulmonary disease. The aim of this study was to evaluate the validity and reliability of the 6PBRT in asthma patients. METHODS Thirty-four adults (30 women, 4 men) with well-controlled asthma were included. Unsupported upper-extremity exercise capacity was assessed using 6PBRT, maximal arm exercise capacity using an arm ergometer, handgrip strength using a hand dynamometer, activities of daily living with the London Chest Activities of Daily Living Scale (LCADL), Milliken ADL scale (MAS) and health-related quality of life using the Asthma Quality of Life Questionnaire (AQLQ) and Health Assessment Questionnaire Disability Index (HAQ-DI). RESULTS The 6PBRT showed moderate to excellent test-retest reliability with an intraclass correlation coefficient (ICC) value of 0.872 [95% confidence interval (CI) 0.702-0.941]. The 6PBRT was reproducible according to Bland-Altman analysis, with upper and lower limits of agreement of 53.51 and -25.08 rings moved, respectively. The 6PBRT score was significantly correlated with maximum workload (r = 0.514, p = 0.002) achieved in the arm ergometer test, change in dyspnea during 6PBRT (r = -0.402, p = 0.020), LCADL-self-care (r = -0.364, p = 0.037), MAS total (r = 0.483, p = 0.005), AQLQ-symptom domain (r = 0.420, p = 0.026) and HAQ-DI total scores (r = -0.390, p = 0.025). CONCLUSIONS The 6PBRT can be used as a valid and reliable test to evaluate functional arm exercise capacity in patients with well-controlled asthma.
Collapse
Affiliation(s)
- Ebru Calik-Kutukcu
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey
| | - Haluk Tekerlek
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey
| | - Cemile Bozdemir-Ozel
- Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Eskisehir Osmangazi University, Eskisehir, Turkey
| | - Beyza Nur Karaduz
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey
| | - Aslihan Cakmak
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey
| | - Deniz Inal-Ince
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey
| | - Melda Saglam
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey
| | - Naciye Vardar-Yagli
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey
| | - Hazal Sonbahar-Ulu
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey
| | - Merve Firat
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey
| | - Hulya Arikan
- Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Atilim University, Ankara, Turkey
| | - Saltuk Bugra Kaya
- Faculty of Medicine, Division of Adult Allergy & Clinical Immunology, Hacettepe University, Ankara, Turkey
| | - Gul Karakaya
- Faculty of Medicine, Division of Adult Allergy & Clinical Immunology, Hacettepe University, Ankara, Turkey
| |
Collapse
|