1
|
Zhu J, Hu J, Zhu K, Ma X, Wang Y, Xu E, Huang Z, Zhu Y, Zhang C. Design of 3D-printed prostheses for reconstruction of periacetabular bone tumors using topology optimization. Front Bioeng Biotechnol 2023; 11:1289363. [PMID: 38116196 PMCID: PMC10728281 DOI: 10.3389/fbioe.2023.1289363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Accepted: 11/22/2023] [Indexed: 12/21/2023] Open
Abstract
Background: Prostheses for the reconstruction of periacetabular bone tumors are prone to instigate stress shielding. The purpose of this study is to design 3D-printed prostheses with topology optimization (TO) for the reconstruction of periacetabular bone tumors and to add porous structures to reduce stress shielding and facilitate integration between prostheses and host bone. Methods: Utilizing patient CT data, we constructed a finite element analysis (FEA) model. Subsequent phases encompassed carrying out TO on the designated area, utilizing the solid isotropic material penalization model (SIMP), and this optimized removal area was replaced with a porous structure. Further analyses included preoperative FEA simulations to comparatively evaluate parameters, including maximum stress, stress distribution, strain energy density (SED), and the relative micromotion of prostheses before and after TO. Furthermore, FEA based on patients' postoperative CT data was conducted again to assess the potential risk of stress shielding subsequent to implantation. Ultimately, preliminary follow-up findings from two patients were documented. Results: In both prostheses, the SED before and after TO increased by 143.61% (from 0.10322 to 0.25145 mJ/mm3) and 35.050% (from 0.30964 to 0.41817 mJ/mm3) respectively, showing significant differences (p < 0.001). The peak stress in the Type II prosthesis decreased by 10.494% (from 77.227 to 69.123 MPa), while there was no significant change in peak stress for the Type I prosthesis. There were no significant changes in stress distribution or the proportion of regions with micromotion less than 28 μm before and after TO for either prosthesis. Postoperative FEA verified results showed that the stress in the pelvis and prostheses remained at relatively low levels. The results of follow-up showed that the patients had successful osseointegration and their MSTS scores at the 12th month after surgery were both 100%. Conclusion: These two types of 3D-printed porous prostheses using TO for periacetabular bone tumor reconstruction offer advantages over traditional prostheses by reducing stress shielding and promoting osseointegration, while maintaining the original stiffness of the prosthesis. Furthermore, in vivo experiments show that these prostheses meet the requirements for daily activities of patients. This study provides a valuable reference for the design of future periacetabular bone tumor reconstruction prostheses.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Chunlin Zhang
- Department of Orthopedic Surgery, Institute of Bone Tumor, Shanghai 10th People’s Hospital Affiliated to Tongji University, Tongji University School of Medicine, Shanghai, China
| |
Collapse
|
2
|
Zhang J, Zhang A, Han Q, Liu Y, Chen H, Ma M, Li Y, Chen B, Wang J. Porous metal block based on topology optimization to treat distal femoral bone defect in total knee revision. Biomech Model Mechanobiol 2023; 22:961-970. [PMID: 36696049 PMCID: PMC10167133 DOI: 10.1007/s10237-023-01692-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 11/26/2022] [Indexed: 01/26/2023]
Abstract
Metal block augmentations are common solutions in treating bone defects of total knee revision. However, the stress shielding and poor osteointegration resulted from metal block application could not be neglected in bone defects restoration. In this study, a novel porous metal block was designed with topology optimization to improve biomechanical performance. The biomechanical difference of the topologically optimized block, solid Ti6Al4V block, and porous Ti6Al4V block in treating bone defects of total knee revision was compared by finite element analysis. The inhomogeneous femoral model was created according to the computed tomography data. Combined with porous structures, minimum compliance topology optimization subjected to the volume fraction constraint was utilized for the redesign of the metal block. The region of interest was defined as a 10 mm area of the distal femur beneath the contacting surface. The biomechanical performance of daily motions was investigated. The von Mises stress, the strain energy density of the region of interest, and the von Mises stress of metal blocks were recorded. The results were analyzed in SPSS. In terms of the region of interest, the maximum von Mises stress of the topological optimized group increased obviously, and its average stress was significantly higher than that of the other groups (p < 0.05). Moreover, the topologically optimized block group had the highest maximum strain energy density of the three groups, and the lowest maximum stress of block was also found in this group. In this study, the stress shielding reduction and stress transfer capability were found obviously improved through topology optimization. Therefore, the topological optimized porous block is recommended in treating bone defects of total knee revision. Meanwhile, this study also provided a novel approach for mechanical optimization in block designing.
Collapse
Affiliation(s)
- Jiangbo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| | - Aobo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| | - Qing Han
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| | - Yang Liu
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| | - Hao Chen
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| | - Mingyue Ma
- Department of Breast Surgery, The First Hospital of Jilin University, Changchun, 130021, China
| | - Yongyue Li
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| | - Bingpeng Chen
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China.
| | - Jincheng Wang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, 130041, China
| |
Collapse
|
3
|
Wan Q, Zhang A, Liu Y, Chen H, Zhang J, Xue H, Han Q, Wang J. The influence of body weight index on initial stability of uncemented femoral knee protheses: A finite element study. Heliyon 2023; 9:e13819. [PMID: 36895366 PMCID: PMC9988490 DOI: 10.1016/j.heliyon.2023.e13819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Revised: 02/07/2023] [Accepted: 02/13/2023] [Indexed: 02/19/2023] Open
Abstract
Background and objective Obesity is one of the risk factors for osteoarthritis. The end-stage treatment for osteoarthritis is total knee arthroplasty (TKA). However, it remains controversial whether a high body mass index (BMI) affects the initial stability of the femoral prosthesis after TKA. Finite element analysis (FEA) was used to investigate this question in this study. Methods Four femur models that assembled with TKA femoral components were reconstructed and divided into high BMI group and normal BMI group. The three-dimensional femurs were modeled and assigned inhomogeneous materials based on computed tomography (CT) images. Then each FEA model was applied with gait and deep bend loading conditions to evaluate the maximum principal strain on the distal femur and the relative micromotion between the femur and prosthesis. Results The mean strain of the high BMI group increased by 32.7% (936.9 με versus 706.1 με) and 50.9% (2064.5 με versus 1368.2 με) under gait and deep bend loading conditions, respectively, compared to the normal BMI group. Meanwhile, the mean micromotion of the high BMI group increased by 41.6% (2.77 μm versus 1.96 μm) and 58.5% (62.1 μm versus 39.2 μm), respectively. Under gait condition, the maximum micromotion for high BMI group was 33.8 μm and would compromise the initial stability. Under deep bend condition, the maximum strain and micromotion exceeded -7300 με and 28 μm for both groups. Conclusion High BMI caused higher strain on the bone and higher micromotion between the prosthesis and the femur. Gait activities could be risky for prosthesis stability in high BMI group while be safe in normal group. Deep bend activities were highly dangerous for both groups with high BMI and normal BMI and should be avoided.
Collapse
Affiliation(s)
- Qian Wan
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Aobo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Yang Liu
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Hao Chen
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Jiangbo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Haowen Xue
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Qing Han
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| | - Jincheng Wang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun 130000, China
| |
Collapse
|
4
|
Shen M, Li Y, Lu F, Gou Y, Zhong C, He S, Zhao C, Yang G, Zhang L, Yang X, Gou Z, Xu S. Bioceramic scaffolds with triply periodic minimal surface architectures guide early-stage bone regeneration. Bioact Mater 2023; 25:374-386. [PMID: 36865987 PMCID: PMC9972395 DOI: 10.1016/j.bioactmat.2023.02.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 01/18/2023] [Accepted: 02/13/2023] [Indexed: 02/19/2023] Open
Abstract
The pore architecture of porous scaffolds is a critical factor in osteogenesis, but it is a challenge to precisely configure strut-based scaffolds because of the inevitable filament corner and pore geometry deformation. This study provides a pore architecture tailoring strategy in which a series of Mg-doped wollastonite scaffolds with fully interconnected pore networks and curved pore architectures called triply periodic minimal surfaces (TPMS), which are similar to cancellous bone, are fabricated by a digital light processing technique. The sheet-TPMS pore geometries (s-Diamond, s-Gyroid) contribute to a 3‒4-fold higher initial compressive strength and 20%-40% faster Mg-ion-release rate compared to the other-TPMS scaffolds, including Diamond, Gyroid, and the Schoen's I-graph-Wrapped Package (IWP) in vitro. However, we found that Gyroid and Diamond pore scaffolds can significantly induce osteogenic differentiation of bone marrow mesenchymal stem cells (BMSCs). Analyses of rabbit experiments in vivo show that the regeneration of bone tissue in the sheet-TPMS pore geometry is delayed; on the other hand, Diamond and Gyroid pore scaffolds show notable neo-bone tissue in the center pore regions during the early stages (3-5 weeks) and the bone tissue uniformly fills the whole porous network after 7 weeks. Collectively, the design methods in this study provide an important perspective for optimizing the pore architecture design of bioceramic scaffolds to accelerate the rate of osteogenesis and promote the clinical translation of bioceramic scaffolds in the repair of bone defects.
Collapse
Affiliation(s)
- Miaoda Shen
- Department of Orthopedics, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, China
| | - Yifan Li
- Department of Orthopedics, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, China
| | - Fengling Lu
- Bio-nanomaterials and Regenerative Medicine Research Division, Zhejiang-California International Nanosystem Institute, Zhejiang University, Hangzhou, 310058, China
| | - Yahui Gou
- Zhejiang University-University of Edinburgh Institute, Zhejiang University, Haining, 314499, China
| | - Cheng Zhong
- Department of Orthopedics, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, China
| | - Shukun He
- Department of Orthopedics, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, China
| | - Chenchen Zhao
- Department of Orthopedics, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, China
| | - Guojing Yang
- Department of Orthopaedics, The Third Hospital Affiliated to Wenzhou Medical University & Rui'an People's Hospital, Rui'an, 325200, China
| | - Lei Zhang
- Department of Orthopaedics, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, 325000, China
| | - Xianyan Yang
- Bio-nanomaterials and Regenerative Medicine Research Division, Zhejiang-California International Nanosystem Institute, Zhejiang University, Hangzhou, 310058, China
| | - Zhongru Gou
- Bio-nanomaterials and Regenerative Medicine Research Division, Zhejiang-California International Nanosystem Institute, Zhejiang University, Hangzhou, 310058, China,Corresponding author.
| | - Sanzhong Xu
- Department of Orthopedics, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, China,Corresponding author.
| |
Collapse
|
5
|
Yue J, Han Q, Chen H, Zhang A, Liu Y, Gong X, Wang Y, Wang J, Wu M. Artificial lamina after laminectomy: Progress, applications, and future perspectives. Front Surg 2023; 10:1019410. [PMID: 36816003 PMCID: PMC9932198 DOI: 10.3389/fsurg.2023.1019410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 01/10/2023] [Indexed: 02/05/2023] Open
Abstract
In clinical practice, laminectomy is a commonly used procedure for spinal decompression in patients suffering from spinal disorders such as ossification of ligamentum flavum, lumbar stenosis, severe spinal fracture, and intraspinal tumors. However, the loss of posterior column bony support, the extensive proliferation of fibroblasts and scar formation after laminectomy, and other complications (such as postoperative epidural fibrosis and iatrogenic instability) may cause new symptoms requiring revision surgery. Implantation of an artificial lamina prosthesis is one of the most important methods to avoid post-laminectomy complications. Artificial lamina is a type of synthetic lamina tissue made of various materials and shapes designed to replace the resected autologous lamina. Artificial laminae can provide a barrier between the dural sac and posterior soft tissues to prevent postoperative epidural fibrosis and paravertebral muscle compression and provide mechanical support to maintain spinal alignment. In this paper, we briefly review the complications of laminectomy and the necessity of artificial lamina, then we review various artificial laminae from clinical practice and laboratory research perspectives. Based on a combination of additive manufacturing technology and finite element analysis for spine surgery, we propose a new designing perspective of artificial lamina for potential use in clinical practice.
Collapse
Affiliation(s)
- Jing Yue
- Department of Anesthesiology, The Second Hospital of Jilin University, Changchun, China
| | - Qing Han
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Hao Chen
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Aobo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Yang Liu
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Xuqiang Gong
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Yang Wang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Jincheng Wang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China,Correspondence: Minfei Wu Jincheng Wang
| | - Minfei Wu
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China,Correspondence: Minfei Wu Jincheng Wang
| |
Collapse
|
6
|
Wan Q, Zhang A, Bai H, Liu Y, Chen H, Zhao X, Wang X, Han Q, Wang J. Cause analysis of the liner dissociation of a customized reverse shoulder prosthesis based on finite element analysis. Front Bioeng Biotechnol 2022; 10:1038116. [DOI: 10.3389/fbioe.2022.1038116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Accepted: 11/22/2022] [Indexed: 12/03/2022] Open
Abstract
Background: Dissociation of the polyethylene liner after reverse shoulder arthroplasty could cause shoulder dislocation that could not achieve closed reduction. The cause of liner dissociation is currently unclear.Method: Non-homogeneous model of the bone was constructed and dynamic finite element analysis was utilized to simulate the impingement of the polyethylene liner and scapula during humeral adduction. The stress distribution of the fixation claws, their degree of deformation (DOD), and the stress of the impingement sites in three initial humeral postures (neutral, 30° flexion, and 30° extension) were measured and analyzed. The influence of the liner material stiffness was also investigated.Result: The impingement stress on the liner and scapula was 100–200 MPa, and different humeral postures caused different locations of impingement points. The fixation claws’ maximum principal stress (MPS) results were below 5 MPa. In the connection area between some fixation claws and the liner, compressive stresses on the inside and tensile stresses on the outside were observed, which showed that the fixation claws were prone to deform toward the center direction. The maximum DOD results of three initial humeral postures (neutral, 30° flexion, and 30° extension) were 3.6%, 2.8%, and 3.5%, respectively. The maximum DOD results of neutral initial humeral posture were 0.51% and 11.4% when the elastic modulus of the liner was increased and decreased by a factor of 10, respectively.Conclusion: The humeral adduction impingement could lead to the deformation of the claw-shaped liner fixation structure, which might be one of the reasons for the liner dissociation. The increased stiffness of the liner material helped to reduce the deformation of the fixation structure.
Collapse
|
7
|
Zhang J, Liu Y, Han Q, Zhang A, Chen H, Ma M, Li Y, Chen B, Wang J. Biomechanical Comparison Between Porous Ti6Al4V Block and Tumor Prosthesis UHMWPE Block for the Treatment of Distal Femur Bone Defects. Front Bioeng Biotechnol 2022; 10:939371. [PMID: 35866028 PMCID: PMC9294404 DOI: 10.3389/fbioe.2022.939371] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 06/16/2022] [Indexed: 11/13/2022] Open
Abstract
Purpose: The management of bone defects is a crucial content of total knee revision. This study compared the biomechanical performance of porous Ti6Al4V block and tumor prosthesis UHMWPE block in treating distal femoral bone defects. Methods: The finite element models of AORI type 3 distal femoral bone defect treated with porous Ti6Al4V block and UHMWPE block were established. Sensitivity analysis was performed to obtain the appropriate mesh size. The biomechanical performance of treatment methods in bone defects were evaluated according to the peak stress, the Von Mises stress distribution, and the average stresses of regions of interest under the condition of standing on one foot and flexion of the knee. Statistical analysis was conducted by independent samples t-test in SPSS (p < 0.05). Results: In the standing on one-foot state, the peak stress of the porous Ti6Al4V block was 12.42 MPa and that of the UHMWPE block was 19.97 MPa, which is close to its yield stress (21 MPa). Meanwhile, the stress distribution of the UHMWPE block was uneven. In the flexion state, the peak stress of the porous Ti6Al4V block was 16.28 MPa, while that of the UHMWPE block was 14.82 MPa. Compared with the porous Ti6Al4V block group, the average stress of the region of interest in UHMWPE block group was higher in the standing on one foot state and lower in the flexion state (p < 0.05). Conclusion: More uniform stress distribution was identified in the porous Ti6Al4V block application which could reserve more bone. On the contrary, uneven stress distribution and a larger high-stress concentration area were found in the UHMWPE block. Hence, the porous Ti6Al4V block is recommended for the treatment of AORI type 3 distal femoral bone defect.
Collapse
Affiliation(s)
- Jiangbo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Yang Liu
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Qing Han
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Aobo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Hao Chen
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Mingyue Ma
- Department of Breast Surgery, The First Hospital of Jilin University, Changchun, China
| | - Yongyue Li
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Bingpeng Chen
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
- *Correspondence: Bingpeng Chen, ; Jincheng Wang,
| | - Jincheng Wang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
- *Correspondence: Bingpeng Chen, ; Jincheng Wang,
| |
Collapse
|
8
|
Xue H, Bai H, Zhou R, Wang J, Zhou B, Wang X, Luo W, Zhao X. Novel Design of the Compound Sleeve and Stem Prosthesis for Treatment of Proximal Femur Bone Defects Based on Topology Optimization. Front Bioeng Biotechnol 2022; 10:938337. [PMID: 35813996 PMCID: PMC9263260 DOI: 10.3389/fbioe.2022.938337] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2022] [Accepted: 06/01/2022] [Indexed: 11/13/2022] Open
Abstract
The loosening of traditional prosthetics is among the leading causes of surgical failure of proximal femoral bone defects. A novel compound sleeve and stem prosthesis was designed using an optimization methodology that combined an octet-truss porous structure with density-based topology optimization to improve stability, promote bone ingrowth, and enhance biomechanical properties. Biomechanical changes were assessed using finite element analysis. The distribution of stress, the strain energy density, and the relative micromotion in the optimized group were considered. The optimized sleeve prosthesis achieved a 31.5% weight reduction. The maximum stresses in the optimized group were observed to decrease by 30.33 and 4.74% at the back sleeve and neck part of stem prosthesis, with a 29.52% increase in the femur, respectively. The average stress in most selected regions in the optimized group was significantly greater than that in the original group (p < 0.05). The maximum relative micromotion decreased by 15.18% (from 63.9 to 54.2 μm) in the optimized group. The novel designed compound sleeve and stem prosthesis could effectively improve the biomechanical performance of next-generation prosthetics and provide a microenvironment for bone ingrowth. The presented method could serve as a model for clinical practice and a platform for future orthopedic surgery applications.
Collapse
Affiliation(s)
- Haowen Xue
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
| | - Haotian Bai
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
| | - Rongqi Zhou
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
| | - Jincheng Wang
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
| | - Bin Zhou
- The Second Clinical Medical College, Jilin University, Changchun, China
| | - Xiaonan Wang
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
| | - Wenbin Luo
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
| | - Xin Zhao
- Department of Orthopedics, the Second Hospital of Jilin University, Changchun, China
- *Correspondence: Xin Zhao,
| |
Collapse
|
9
|
Zhou R, Xue H, Wang J, Wang X, Wang Y, Zhang A, Zhang J, Han Q, Zhao X. Improving the Stability of a Hemipelvic Prosthesis Based on Bone Mineral Density Screw Channel and Prosthesis Optimization Design. Front Bioeng Biotechnol 2022; 10:892385. [PMID: 35706507 PMCID: PMC9189365 DOI: 10.3389/fbioe.2022.892385] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 05/16/2022] [Indexed: 11/13/2022] Open
Abstract
In pelvic reconstruction surgery, the hemipelvic prosthesis can cause significant changes in stress distribution due to its high stiffness, and its solid structure is not suitable for osseointegration. The purpose of this study was to identify a novel bone mineral density screw channel and design the structure of the prosthesis so as to improve the distribution of stress, promote bone growth, and enhance the biomechanical properties of the prosthesis. The mechanical characteristics of bone mineral density screw and traditional screw were compared by finite element analysis method, and redesigned by topology optimization. The direction of the newly proposed screw channel was the posterolateral entrance of the auricular surface, ending at the contralateral sacral cape. Compared to the original group, the maximum stress of the optimized prosthesis was decreased by 24.39%, the maximum stress of the sacrum in the optimized group was decreased by 27.23%, and the average strain energy density of the sacrum in the optimized group was increased by 8.43%. On the surface of screw and connecting plate, the area with micromotion more than 28 μm is reduced by 12.17%. On the screw surface, the area with micromotion more than 28 μm is reduced by 22.9%. The newly determined screw channel and optimized prosthesis design can effectively improve the biomechanical properties of a prosthesis and the microenvironment of osseointegration. This method can provide a reference for the fixation of prostheses in clinical pelvic reconstruction.
Collapse
|
10
|
Wu PK, Lee CW, Sun WH, Lin CL. Biomechanical Analysis and Design Method for Patient-Specific Reconstructive Implants for Large Bone Defects of the Distal Lateral Femur. BIOSENSORS 2021; 12:4. [PMID: 35049632 PMCID: PMC8773582 DOI: 10.3390/bios12010004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 12/09/2021] [Accepted: 12/19/2021] [Indexed: 05/03/2023]
Abstract
This study aims to develop a generalizable method for designing a patient-specific reconstructive scaffold implant for a large distal lateral femur defect using finite element (FE) analysis and topology optimization. A 3D solid-core implant for the distal femur defect was designed to withhold the femur load. Data from FE analysis of the solid implant were use for topology optimization to obtain a 'bone scaffold implant' with light-weight internal cavity and surface lattice features to allow for filling with bone material. The bone scaffold implant weighed 69.6% less than the original solid-core implant. The results of FE simulation show that the bone repaired with the bone scaffold implant had lower total displacement (12%), bone plate von Mises stress (34%), bone maximum first principal stress (33%), and bone maximum first principal strain (32%) than did bone repaired with bone cement. The trend in experimental strain with increasing load on the composite femur was greater with bone cement than with the bone scaffold implant. This study presents a generalizable method for designing a patient-specific reconstructive scaffold implant for the distal lateral femur defect that has sufficient strength and space for filling with allograft bone.
Collapse
Affiliation(s)
- Po-Kuei Wu
- Department of Orthopaedics, Therapeutical and Research Center of Musculoskeletal Tumor, Taipei Veterans General Hospital, Taipei 112, Taiwan;
- Orthopaedic Department School of Medicine, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
| | - Cheng-Wei Lee
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 112, Taiwan; (C.-W.L.); (W.-H.S.)
| | - Wei-Hsiang Sun
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 112, Taiwan; (C.-W.L.); (W.-H.S.)
| | - Chun-Li Lin
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 112, Taiwan; (C.-W.L.); (W.-H.S.)
- Medical Device Innovation & Translation Center, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
| |
Collapse
|
11
|
Liu Y, Chen B, Wang C, Chen H, Zhang A, Yin W, Wu N, Han Q, Wang J. Design of Porous Metal Block Augmentation to Treat Tibial Bone Defects in Total Knee Arthroplasty Based on Topology Optimization. Front Bioeng Biotechnol 2021; 9:765438. [PMID: 34820364 PMCID: PMC8606634 DOI: 10.3389/fbioe.2021.765438] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 10/04/2021] [Indexed: 11/13/2022] Open
Abstract
Metal block augmentation, which is used for the treatment of tibial bone defects in total knee arthroplasty, with high stiffness will cause significant alteration in stress distribution, and its solid structure is not suitable for osseointegration. This study aimed to design a porous block to reduce weight, promote bone ingrowth, and improve its biomechanical performance. The metal block augmentation technique was applied to finite element models of tibial bone defects. Minimum compliance topology optimization subject to volume fraction combined with the porous architecture was adopted to redesign the block. Biomechanical changes compared with the original block were analyzed by finite element analysis. The stress distribution of the block and proximal tibia was recorded. The strain energy density of the proximal tibia was obtained. The newly designed block realized 40% weight reduction. The maximum stress in the optimized block decreased by 11.6% when compared with the solid one. The maximum stress of the proximal tibia in the optimized group increased by 18.6%. The stress of the anterior, medial, and posterior parts of the proximal medial tibia in the optimized group was significantly greater than that in the original group (all p < 0.05). The optimized block could effectively improve the biomechanical performance between the block and the bone. The presented method might provide a reference for the design of customized three-dimensional printed prostheses.
Collapse
Affiliation(s)
- Yang Liu
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Bingpeng Chen
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Chenyu Wang
- Department of Plastic and Reconstructive Surgery, First Bethune Hospital of Jilin University, Changchun, China
| | - Hao Chen
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Aobo Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Weihuang Yin
- Department of Oral and Maxillofacial Surgery, Hospital of Stomatology, Jilin University, Changchun, China
| | - Naichao Wu
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Qing Han
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| | - Jincheng Wang
- Department of Orthopedics, The Second Hospital of Jilin University, Changchun, China
| |
Collapse
|
12
|
Wang H, Wan Y, Li Q, Liu X, Yu M, Zhang X, Xia Y, Sun Q, Liu Z. Multiscale design and biomechanical evaluation of porous spinal fusion cage to realize specified mechanical properties. Biodes Manuf 2021. [DOI: 10.1007/s42242-021-00162-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|