1
|
Brouwer de Koning SG, de Winter N, Moosabeiki V, Mirzaali MJ, Berenschot A, Witbreuk MMEH, Lagerburg V. Design considerations for patient-specific bone fixation plates: a literature review. Med Biol Eng Comput 2023; 61:3233-3252. [PMID: 37691047 DOI: 10.1007/s11517-023-02900-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2023] [Accepted: 07/29/2023] [Indexed: 09/12/2023]
Abstract
In orthopedic surgery, patient-specific bone plates are used for fixation when conventional bone plates do not fit the specific anatomy of a patient. However, plate failure can occur due to a lack of properly established design parameters that support optimal biomechanical properties of the plate.This review provides an overview of design parameters and biomechanical properties of patient-specific bone plates, which can assist in the design of the optimal plate.A literature search was conducted through PubMed and Embase, resulting in the inclusion of 78 studies, comprising clinical studies using patient-specific bone plates for fracture fixation or experimental studies that evaluated biomechanical properties or design parameters of bone plates. Biomechanical properties of the plates, including elastic stiffness, yield strength, tensile strength, and Poisson's ratio are influenced by various factors, such as material properties, geometry, interface distance, fixation mechanism, screw pattern, working length and manufacturing techniques.Although variations within studies challenge direct translation of experimental results into clinical practice, this review serves as a useful reference guide to determine which parameters must be carefully considered during the design and manufacturing process to achieve the desired biomechanical properties of a plate for fixation of a specific type of fracture.
Collapse
Affiliation(s)
| | - N de Winter
- Medical Physics, OLVG Hospital, Oosterpark 9, 1091 AC, Amsterdam, The Netherlands
| | - V Moosabeiki
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology, Delft, The Netherlands
| | - M J Mirzaali
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology, Delft, The Netherlands
| | - A Berenschot
- Medical Library, Department of Research and Epidemiology, OLVG Hospital, Amsterdam, The Netherlands
| | | | - V Lagerburg
- Medical Physics, OLVG Hospital, Oosterpark 9, 1091 AC, Amsterdam, The Netherlands.
| |
Collapse
|
2
|
Moosabeiki V, de Winter N, Cruz Saldivar M, Leeflang MA, Witbreuk MMEH, Lagerburg V, Mirzaali MJ, Zadpoor AA. 3D printed patient-specific fixation plates for the treatment of slipped capital femoral epiphysis: Topology optimization vs. conventional design. J Mech Behav Biomed Mater 2023; 148:106173. [PMID: 37866280 DOI: 10.1016/j.jmbbm.2023.106173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 10/05/2023] [Accepted: 10/09/2023] [Indexed: 10/24/2023]
Abstract
Orthopedic plates are commonly used after osteotomies for temporary fixation of bones. Patient-specific plates have recently emerged as a promising fixation device. However, it is unclear how various strategies used for the design of such plates perform in comparison with each other. Here, we compare the biomechanical performance of 3D printed patient-specific bone plates designed using conventional computer-aided design (CAD) techniques with those designed with the help of topology optimization (TO) algorithms, focusing on cases involving slipped capital femoral epiphysis (SCFE). We established a biomechanical testing protocol to experimentally assess the performance of the designed plates while measuring the full-field strain using digital image correlation. We also created an experimentally validated finite element model to analyze the performance of the plates under physiologically relevant loading conditions. The results indicated that the TO construct exhibited higher ultimate load and biomechanical performance as compared to the CAD construct, suggesting that TO is a viable approach for the design of such patient-specific bone plates. The TO plate also distributed stress more evenly over the screws, likely resulting in more durable constructs and improved anatomical conformity while reducing the risk of screw and plate failure during cyclic loading. Although differences existed between finite element analysis and experimental testing, this study demonstrated that finite element modelling can be used as a reliable method for evaluating and optimizing plates for SCFE patients. In addition to enhancing the mechanical performance of patient-specific fixation plates, the utilization of TO in plate design may also improve the surgical outcome and decrease the recovery time by reducing the plate and incision sizes.
Collapse
Affiliation(s)
- V Moosabeiki
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628, CD, Delft, the Netherlands.
| | - N de Winter
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628, CD, Delft, the Netherlands; Medical Physics, OLVG, Oosterpark 9, 1091, AC, Amsterdam, the Netherlands
| | - M Cruz Saldivar
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628, CD, Delft, the Netherlands
| | - M A Leeflang
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628, CD, Delft, the Netherlands
| | - M M E H Witbreuk
- Department of Orthopaedic Surgery, OLVG, Oosterpark 9, 1091, AC, Amsterdam, the Netherlands
| | - V Lagerburg
- Medical Physics, OLVG, Oosterpark 9, 1091, AC, Amsterdam, the Netherlands
| | - M J Mirzaali
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628, CD, Delft, the Netherlands
| | - A A Zadpoor
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628, CD, Delft, the Netherlands; Department of Orthopedic Surgery, Leiden University Medical Center, Albinusdreef 2, 2333, ZA, Leiden, the Netherlands
| |
Collapse
|
3
|
Wang L, Geng W, He K, Guo K. Convenient design method for customized implants based on bionic vein structure features. Front Bioeng Biotechnol 2022; 10:929133. [PMID: 36032731 PMCID: PMC9412103 DOI: 10.3389/fbioe.2022.929133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 06/30/2022] [Indexed: 11/22/2022] Open
Abstract
Matching implants to bones is crucial for customized orthopedic medicine. Existing methods for designing customized implants predominantly adopt the parameterized deformation method that uses a fragmented representation of semantic parameters. Such a representation cannot provide information integration management and therefore restricts the retrieval of information regarding implant features and the improvement of customized design efficiency. Therefore, this study proposes a rapid design method for customized implants based on bionic vein structure features. First, a bionic vein structure was designed to represent the implant type. Second, the bionic vein structure was represented by a digraph structure with morphological and dimensional features. Finally, the implant model was rapidly built by retrieving the sketch and other modeling operations. Common implants such as the T-shaped plate, L-shaped plate, clover plate, and femoral stem prosthesis were used as explanations or test cases. The experimental work shows that combining the traditional parametric deformation method with bionic vein structure features in our present method is flexible and efficient results, and can improve the efficiency of customized implant design.
Collapse
Affiliation(s)
- Lin Wang
- School of Medical Information and Engineering, Xuzhou Medical University, Xuzhou, China
- *Correspondence: Lin Wang,
| | - Weizhong Geng
- College of Computer and Information Engineering, XinXiang University, XinXiang, China
| | - Kunjin He
- College of Internet of Things Engineering, Hohai University, Changzhou, China
| | - Kaijin Guo
- Department of Orthopedics, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| |
Collapse
|
4
|
Wang L, Guo K, He K, Zhu H. Bone morphological feature extraction for customized bone plate design. Sci Rep 2021; 11:15617. [PMID: 34341376 PMCID: PMC8329034 DOI: 10.1038/s41598-021-94924-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 07/19/2021] [Indexed: 01/01/2023] Open
Abstract
Fractures are difficult to treat because of individual differences in bone morphology and fracture types. Compared to serialized bone plates, the use of customized plates significantly improves the fracture healing process. However, designing custom plates often requires the extraction of skeletal morphology, which is a complex and time-consuming procedure. This study proposes a method for extracting bone morphological features to facilitate customized plate designs. The customized plate design involves three major steps: extracting the morphological features of the bone, representing the undersurface features of the plate, and constructing the customized plate. Among these steps, constructing the undersurface feature involves integrating a group of bone features with different anatomical morphologies into a semantic feature parameter set of the plate feature. The undersurface feature encapsulates the plate and bone features into a highly cohesive generic feature and then establishes an internal correlation between the plate and bone features. Using the femoral plate as an example, we further examined the validity and feasibility of the proposed method. The experimental results demonstrate that the proposed method improves the convenience of redesign through the intuitive editing of semantic parameters. In addition, the proposed method significantly improves the design efficiency and reduces the required design time.
Collapse
Affiliation(s)
- Lin Wang
- School of Medical Information and Engineering, Xuzhou Medical University, Xuzhou, 221004, People's Republic of China.
| | - Kaijin Guo
- Department of Orthopedics, Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221006, People's Republic of China
| | - Kunjin He
- College of Internet of Things Engineering, Hohai University, Changzhou, 213022, People's Republic of China
| | - Hong Zhu
- School of Medical Information and Engineering, Xuzhou Medical University, Xuzhou, 221004, People's Republic of China
| |
Collapse
|