1
|
Cohen A, Selton-Suty C, Danchin N. A tribute to Yves Juillière, MD, PhD (1957 to 2021). Arch Cardiovasc Dis 2021. [PMID: 33972175 DOI: 10.1016/j.acvd.2021.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Ariel Cohen
- Saint-Antoine and Tenon Hospitals, AP-HP, INSERM UMRS-ICAN 1166 Sorbonne Université and French society of cardiology 2020-2022 President, 184, rue du Faubourg Saint-Antoine, 75012 Paris, France.
| | - Christine Selton-Suty
- Department of cardiology, Centre hospitalier régional universitaire de Nancy, 54511 Vandœuvre-Lès-Nancy, France
| | - Nicolas Danchin
- Department of cardiology, Hôpital européen Georges-Pompidou, Paris, France
| |
Collapse
|
2
|
Serruys PW, Chichareon P, Modolo R, Leaman DM, Reiber JH, Emanuelsson H, Di Mario C, Pijls NH, Morel MA, Valgimigli M, Farooq V, van Klaveren D, Capodanno D, Andreini D, Bourantas CV, Davies J, Banning AP, Escaned J, Piek JJ, Echavarría-Pinto M, Taylor CA, Thomsen B, Collet C, Pompilio G, Bartorelli AL, Glocker B, Dressler O, Stone GW, Onuma Y. The SYNTAX score on its way out or … towards artificial intelligence: part I. EUROINTERVENTION 2020; 16:44-59. [DOI: 10.4244/eij-d-19-00543a] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
3
|
Cardiovascular research in France: Evolution of scientific activities and production over the last decade. Arch Cardiovasc Dis 2019; 112:241-252. [PMID: 30639381 DOI: 10.1016/j.acvd.2018.11.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Accepted: 11/12/2018] [Indexed: 11/23/2022]
Abstract
BACKGROUND Cardiovascular disease (CVD) is a major cause of death worldwide, and fruitful research is needed for future advances in this field. AIMS To analyse the scientific production and vitality of French cardiovascular clinical research, and its evolution over the last decade. METHODS We first used Lab Times online data obtained through the Web of Science (Thomson-Reuters, Toronto, ON, Canada), then the PubMed database (National Center for Biotechnology Information [NCBI], Bethesda, MD, USA), for studies published between 2005 and 2015 in the multidisciplinary and cardiology journals with the highest impact factors. French abstracts submitted and accepted at the European Society of Cardiology (ESC) congress were provided directly by the ESC. The number of cardiovascular projects was analysed through the http://www.ClinicalTrials.gov database and the French site for government-funded projects, over the decade from 2008 to 2017. RESULTS Overall, France was ranked fifth in Europe and eighth worldwide for CVD publications. During the 10-year period from 2005 to 2015, French publications accounted for 0.2-0.3% of articles in top multidisciplinary journals and 2% of articles in top cardiology journals. We observed a steady decrease in French abstract submissions at the ESC congress (from 5% to 3.5% in 10 years), and in 2017, France was ranked eighth in Europe. Across European countries, France has been ranked first for declared cardiovascular research on http://www.ClinicalTrials.gov over the last 3 years, for both interventional and observational studies. Regarding the Hospital Programme of Clinical Research, heart ranked second after neurosciences. CONCLUSIONS France is very well represented in terms of new CVD projects, but actual French scientific production scores poorly. Investing in CVD research is a priority to increase the level of publication and to compete with other leading countries.
Collapse
|
4
|
Feinberg J, Nielsen EE, Gluud C, Jakobsen JC. Cochrane Corner: drug-eluting stents versus bare-metal stents for acute coronary syndrome. Heart 2018; 104:1895-1897. [DOI: 10.1136/heartjnl-2017-312931] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
|
5
|
Feinberg J, Nielsen EE, Greenhalgh J, Hounsome J, Sethi NJ, Safi S, Gluud C, Jakobsen JC. Drug-eluting stents versus bare-metal stents for acute coronary syndrome. Cochrane Database Syst Rev 2017; 8:CD012481. [PMID: 28832903 PMCID: PMC6483499 DOI: 10.1002/14651858.cd012481.pub2] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
BACKGROUND Approximately 3.7 million people died from acute coronary syndrome worldwide in 2012. Acute coronary syndrome, also known as myocardial infarction or unstable angina pectoris, is caused by a sudden blockage of the blood supplied to the heart muscle. Percutaneous coronary intervention is often used for acute coronary syndrome, but previous systematic reviews on the effects of drug-eluting stents compared with bare-metal stents have shown conflicting results with regard to myocardial infarction; have not fully taken account of the risk of random and systematic errors; and have not included all relevant randomised clinical trials. OBJECTIVES To assess the benefits and harms of drug-eluting stents versus bare-metal stents in people with acute coronary syndrome. SEARCH METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS, SCI-EXPANDED, and BIOSIS from their inception to January 2017. We also searched two clinical trials registers, the European Medicines Agency and the US Food and Drug Administration databases, and pharmaceutical company websites. In addition, we searched the reference lists of review articles and relevant trials. SELECTION CRITERIA Randomised clinical trials assessing the effects of drug-eluting stents versus bare-metal stents for acute coronary syndrome. We included trials irrespective of publication type, status, date, or language. DATA COLLECTION AND ANALYSIS We followed our published protocol and the methodological recommendations of Cochrane. Two review authors independently extracted data. We assessed the risks of systematic error by bias domains. We conducted Trial Sequential Analyses to control the risks of random errors. Our primary outcomes were all-cause mortality, major cardiovascular events, serious adverse events, and quality of life. Our secondary outcomes were angina, cardiovascular mortality, and myocardial infarction. Our primary assessment time point was at maximum follow-up. We assessed the quality of the evidence by the GRADE approach. MAIN RESULTS We included 25 trials randomising a total of 12,503 participants. All trials were at high risk of bias, and the quality of evidence according to GRADE was low to very low. We included 22 trials where the participants presented with ST-elevation myocardial infarction, 1 trial where participants presented with non-ST-elevation myocardial infarction, and 2 trials where participants presented with a mix of acute coronary syndromes.Meta-analyses at maximum follow-up showed no evidence of a difference when comparing drug-eluting stents with bare-metal stents on the risk of all-cause mortality or major cardiovascular events. The absolute risk of death was 6.97% in the drug-eluting stents group compared with 7.74% in the bare-metal stents group based on the risk ratio (RR) of 0.90 (95% confidence interval (CI) 0.78 to 1.03, 11,250 participants, 21 trials/22 comparisons, low-quality evidence). The absolute risk of a major cardiovascular event was 6.36% in the drug-eluting stents group compared with 6.63% in the bare-metal stents group based on the RR of 0.96 (95% CI 0.83 to 1.11, 10,939 participants, 19 trials/20 comparisons, very low-quality evidence). The results of Trial Sequential Analysis showed that we did not have sufficient information to confirm or reject our anticipated risk ratio reduction of 10% on either all-cause mortality or major cardiovascular events at maximum follow-up.Meta-analyses at maximum follow-up showed evidence of a benefit when comparing drug-eluting stents with bare-metal stents on the risk of a serious adverse event. The absolute risk of a serious adverse event was 18.04% in the drug-eluting stents group compared with 23.01% in the bare-metal stents group based on the RR of 0.80 (95% CI 0.74 to 0.86, 11,724 participants, 22 trials/23 comparisons, low-quality evidence), and Trial Sequential Analysis confirmed this result. When assessing each specific type of adverse event included in the serious adverse event outcome separately, the majority of the events were target vessel revascularisation. When target vessel revascularisation was analysed separately, meta-analysis showed evidence of a benefit of drug-eluting stents, and Trial Sequential Analysis confirmed this result.Meta-analyses at maximum follow-up showed no evidence of a difference when comparing drug-eluting stents with bare-metal stents on the risk of cardiovascular mortality (RR 0.91, 95% CI 0.76 to 1.09, 9248 participants, 14 trials/15 comparisons, very low-quality evidence) or myocardial infarction (RR 0.98, 95% CI 0.82 to 1.18, 10,217 participants, 18 trials/19 comparisons, very low-quality evidence). The results of the Trial Sequential Analysis showed that we had insufficient information to confirm or reject our anticipated risk ratio reduction of 10% on cardiovascular mortality and myocardial infarction.No trials reported results on quality of life or angina. AUTHORS' CONCLUSIONS The current evidence suggests that drug-eluting stents may lead to fewer serious adverse events compared with bare-metal stents without increasing the risk of all-cause mortality or major cardiovascular events. However, our Trial Sequential Analysis showed that there currently was not enough information to assess a risk ratio reduction of 10% for all-cause mortality, major cardiovascular events, cardiovascular mortality, or myocardial infarction, and there were no data on quality of life or angina. The evidence in this review was of low to very low quality, and the true result may depart substantially from the results presented in this review.More randomised clinical trials with low risk of bias and low risks of random errors are needed if the benefits and harms of drug-eluting stents for acute coronary syndrome are to be assessed properly. More data are needed on the outcomes all-cause mortality, major cardiovascular events, quality of life, and angina to reduce the risk of random error.
Collapse
Affiliation(s)
- Joshua Feinberg
- Copenhagen Trial Unit, Centre for Clinical Intervention Research, Department 7812, Rigshospitalet, Copenhagen University Hospital, Blegdamsvej 9, Copenhagen, Denmark, 2100
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Echavarría-Pinto M, Collet C, Escaned J, Piek J, Serruys P. State of the art: pressure wire and coronary functional assessment. EUROINTERVENTION 2017; 13:666-679. [DOI: 10.4244/eij-d-17-00503] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
7
|
Feinberg J, Nielsen EE, Greenhalgh J, Hounsome J, Sethi NJ, Safi S, Gluud C, Jakobsen JC. Drug-eluting stents versus bare-metal stents for acute coronary syndrome. Cochrane Database Syst Rev 2016. [DOI: 10.1002/14651858.cd012481] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
8
|
Nielsen EE, Feinberg J, Greenhalgh J, Hounsome J, Sethi NJ, Safi S, Gluud C, Jakobsen JC. Drug-eluting stents versus bare-metal stents for stable ischaemic heart disease. Cochrane Database Syst Rev 2016. [DOI: 10.1002/14651858.cd012480] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Affiliation(s)
- Emil Eik Nielsen
- Department 7812, Rigshospitalet, Copenhagen University Hospital; Copenhagen Trial Unit, Centre for Clinical Intervention Research; Blegdamsvej 9 Copenhagen Denmark 2100
| | - Joshua Feinberg
- Department 7812, Rigshospitalet, Copenhagen University Hospital; Copenhagen Trial Unit, Centre for Clinical Intervention Research; Blegdamsvej 9 Copenhagen Denmark 2100
| | - Janette Greenhalgh
- University of Liverpool; Liverpool Reviews and Implementation Group; Sherrington Building Ashton Street Liverpool UK L69 3GE
| | - Juliet Hounsome
- University of Liverpool; Liverpool Reviews and Implementation Group; Sherrington Building Ashton Street Liverpool UK L69 3GE
| | - Naqash J Sethi
- Department 7812, Rigshospitalet, Copenhagen University Hospital; Copenhagen Trial Unit, Centre for Clinical Intervention Research; Blegdamsvej 9 Copenhagen Denmark 2100
| | - Sanam Safi
- Department 7812, Rigshospitalet, Copenhagen University Hospital; Copenhagen Trial Unit, Centre for Clinical Intervention Research; Blegdamsvej 9 Copenhagen Denmark 2100
| | - Christian Gluud
- Copenhagen Trial Unit, Centre for Clinical Intervention Research, Department 7812, Rigshospitalet, Copenhagen University Hospital; The Cochrane Hepato-Biliary Group; Blegdamsvej 9 Copenhagen Denmark DK-2100
| | - Janus C Jakobsen
- Copenhagen Trial Unit, Centre for Clinical Intervention Research, Department 7812, Rigshospitalet, Copenhagen University Hospital; The Cochrane Hepato-Biliary Group; Blegdamsvej 9 Copenhagen Denmark DK-2100
- Holbaek Hospital; Department of Cardiology; Holbaek Denmark 4300
| |
Collapse
|
9
|
Raval A, Choubey A, Engineer C, Kothwala D. Surface Conditioning of 316LVM Slotted Tube Cardiovascular Stents. J Biomater Appl 2016; 19:197-213. [PMID: 15613380 DOI: 10.1177/0885328205046564] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The surface quality of coronary stents has a significant influence on its biocompatibility. Therefore, surface polishing is of paramount importance in the production and application of stents. In the present study, electropolishing is performed on 316LVM steel slotted tube coronary stents. Additionally, acid pickling, as a pretreatment of electropolishing, is also conducted. Gravimetric analysis of the stents (weight loss and strut width change) in the process of acid pickling and electropolishing are done. Qualitative roughness measurements are made to evaluate the stent surface. Electropolished stents are passivated causing chromium enrichment on the surface of the material, thereby enhancing its corrosion resistance. Passivated and electropolished samples are examined using energy dispersive spectrometry. Balloon expanded and crimped profiles of the passivated stents are qualitatively analyzed.
Collapse
Affiliation(s)
- Ankur Raval
- Research and Development Division, Sahajanand Medical Technologies, Surat-GJ 395 003, India.
| | | | | | | |
Collapse
|
10
|
SCHEERDER IVAN, SOHIER JÜRGEN, WANG KAI, VERBEKEN ERIC, ZHOU XIOUR, FROYEN LUDO, HUMBEECK JAN, PIESSENS JAN, WERF FRANS. Metallic Surface Treatment Using Electrochemical Polishing Decreases Thrombogenicity and Neointimal Hyperplasia of Coronary Stents. J Interv Cardiol 2000. [DOI: 10.1111/j.1540-8183.2000.tb00286.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
11
|
De Scheerder I, Wang K, Wilczek K, Meuleman D, Van Amsterdam R, Vogel G, Piessens J, Van de Werf F. Experimental study of thrombogenicity and foreign body reaction induced by heparin-coated coronary stents. Circulation 1997; 95:1549-53. [PMID: 9118524 DOI: 10.1161/01.cir.95.6.1549] [Citation(s) in RCA: 71] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Results of recent randomized clinical trials have revealed a significant reduction in angiographic restenosis rate when adjunctive stenting was performed after conventional coronary balloon angioplasty. The thrombogenicity of metal stents, however, remains a concern. In the present study, we compare the thrombogenicity of heparin-coated coronary stents with that of bare metallic coronary stents. METHODS AND RESULTS Thrombogenicity of metallic coronary stents (four heparin-coated and eight bare stents) was studied in a rat arteriovenous shunt model with the use of 125I-labeled fibrinogen and 51Cr-labeled platelets. Total clot weight after 30-minute follow-up was significantly lower in the heparin-coated stents compared with the bare stents (8.1 +/- 3.7 versus 25.8 +/- 4.6 mg; P < .001). Relative 125I and 51Cr activities in the stents were significantly higher in the bare stents than in the heparin-coated stents (125I, 1.03 +/- 0.43 versus 0.18 +/- 0.04, P = .003; 51Cr, 17.5 +/- 6.8 versus 4.4 +/- 1.0, P = .004). Subsequently, heparin-coated and bare stents were randomly implanted in the right coronary artery of 20 domestic pigs. Angiographic parameters were similar between both groups at baseline and after 6-week follow-up. Morphometry also did not show a significant difference in lumen area (bare, 1.03 +/- 0.83 mm2; heparin-coated, 1.12 +/- 0.73 mm2; P = NS) or neointimal hyperplasia (bare, 1.01 +/- 0.81 mm2; heparin-coated, 1.21 +/- 0.57 mm2; P = NS). CONCLUSIONS Heparin coating of metallic coronary stents decreases their thrombogenicity but does not improve late vessel patency and neointimal hyperplasia at follow-up in a porcine coronary model.
Collapse
Affiliation(s)
- I De Scheerder
- Department of Cardiology, Gasthuisberg University Hospital, Leuven, Belgium
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Versaci F, Tomai F, Nudi F, Gaspardone A, De Fazio A, Ciavolella M, Crea F, Mango L, Chiariello L, Gioffrè PA. Differences of regional coronary flow reserve assessed by adenosine thallium-201 scintigraphy early and six months after successful percutaneous transluminal coronary angioplasty or stent implantation. Am J Cardiol 1996; 78:1097-102. [PMID: 8914870 DOI: 10.1016/s0002-9149(96)90059-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
This study assesses regional coronary flow reserve using adenosine thallium-201 scintigraphy early and 6 months after angiographically successful percutaneous transluminal coronary angioplasty (PTCA) or stent implantation. Seventeen consecutive men with a significant isolated left anterior descending coronary artery stenosis were scheduled for repeat coronary angiography and adenosine-planar thallium-201 scintigraphy within 24 hours and 6 months after successful PTCA (n = 8) or stent implantation (n = 9). After background subtraction, left ventricular segmental uptake was semiquantitatively assessed on thallium images. The perfusion defect severity was scored from 0 (normal) to 3. Coronary angiograms were analyzed using an automated edge contour detection computer analysis system. Data are expressed as mean value +/- 1 SD, and proportions as percentage. The residual narrowing was 17 +/- 8% after PTCA and 9 +/- 2% after stent implantation (p = 0.02). Twenty-four hours after the procedure, hypoperfused segments were detected in all patients (100%) and in 4 patients (44%) (p = 0.05), respectively. The total number of hypoperfused segments was greater after PTCA than after stent implantation (16 [40%] vs 7 [16%], p = 0.001, respectively) as was the perfusion defect severity (4.4 +/- 3.1 vs 1 +/- 1.2, p = 0.006). Six months after the procedure, 3 of the 5 patients who had undergone PTCA without restenosis still had reversible perfusion defects. None of the stent-treated patients had restenosis or reversible perfusion defects (p = 0.05). Among PTCA-treated patients without restenosis, the total number of hypoperfused segments and the perfusion defect severity were 9 of 25 (36%) and 0.8 +/- 0.8, respectively. Thus, a regional reduction in coronary flow reserve, occasionally observed early after successful stent implantation, is probably due to a transient alteration of small coronary vessels, as was also supported by the absence of perfusion defects 6 months after the procedure. The more severe impairment of regional coronary flow reserve observed early after successful PTCA is probably also due to angiographic underestimation of the residual stenosis, as suggested also by the persistence of reversible perfusion defects 6 months after the procedure in a few patients.
Collapse
Affiliation(s)
- F Versaci
- Servizio Speciale di Diagnosi e Cura di Emodinamica, Divizione di Cardiochiurgia, Università di Roma Tor Vergata, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Stefanadis C, Toutouzas K, Vlachopoulos C, Stratos C, Kallikazaros I, Karayannakos P, Gravanis MM, Robinson K, Toutouzas P. Stents wrapped in autologous vein: an experimental study. J Am Coll Cardiol 1996; 28:1039-46. [PMID: 8837587 DOI: 10.1016/s0735-1097(96)00267-7] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVES A new type of coated stent, consisting of a conventional stent covered by an autologous vein graft, was developed at our institution. BACKGROUND Coated stents are under investigation to address stenting limitations. However, experimental implantation of coated stents covered by autologous tissue has not been reported. METHODS An autologous vein graft was removed and carefully prepared. Subsequently, a Palmaz stent was covered by the vein graft both internally and externally. Twenty-seven stents were implanted in the normal iliac arteries of 27 pigs weighing 18 to 33 kg. In 15 of the pigs, 15 noncoated Palmaz stents were implanted in the contralateral artery; these animals served as the control group. The animals were followed up angiographically for a period ranging from 7 days to 6 months. At the time of death, the stented segments were removed, and histomorphometric analysis was performed. RESULTS Autologous vein graft-coated stent preparation and implantation was feasible and uncomplicated. In both stents, angiographic follow-up revealed the absence of thrombosis, except for two cases of subacute thrombosis in the control group. The thickness of the intimal layer was greater in the coated stents and seems to be due to the existence of the internal vein layer ([mean +/- SD] 0.57 +/- 0.12 vs. 0.27 +/- 0.13 mm, p = 0.001). The arterial media of the coated stent segments was thinner than that in the control group (0.14 +/- 0.03 vs. 0.18 +/- 0.01 mm, p = 0.02). CONCLUSIONS The autologous vein graft-coated stent seems to be nonthrombogenic, and only minimal hyperplasia was observed in the pigs. Further studies are needed to explore the efficacy of this technique in humans.
Collapse
Affiliation(s)
- C Stefanadis
- Department of Cardiology, Hippokration Hospital, University of Athens, Greece
| | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Stefanadis C, Toutouzas K, Vlachopoulos C, Tsiamis E, Kallikazaros I, Stratos C, Vavuranakis M, Toutouzas P. Autologous vein graft-coated stent for treatment of coronary artery disease. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS 1996; 38:159-70. [PMID: 8776519 DOI: 10.1002/(sici)1097-0304(199606)38:2<159::aid-ccd8>3.0.co;2-8] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Acute or subacute thrombosis and late restenosis remain the main limitations of permanent stenting. In an effort to address these limitations, an autologous vein graft-coated stent (AVGCS) was developed at our institution. This stent consists of a conventional stent (Palmaz or Palmaz-Schatz, Johnson and Johnson), which is covered by an autologous vein graft. After successful experimental implantation, we report here the immediate results of the percutaneous implantation of AVGCS in 7 patients with coronary artery disease (6 de novo lesions and 1 bailout case). The results of this preliminary study indicate that the preparation of the AVGCS is easy and feasible. The implantation of the AVGCS was uncomplicated, and the immediate angiographic results were excellent. This new type of coated stent may be useful in addressing current limitations of balloon angioplasty.
Collapse
Affiliation(s)
- C Stefanadis
- Department of Cardiology, Hippokration Hospital, University of Athens, Greece
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Strauss BH, Escaned J, Foley DP, di Mario C, Haase J, Keane D, Hermans WR, de Feyter PJ, Serruys PW. Technologic considerations and practical limitations in the use of quantitative angiography during percutaneous coronary recanalization. Prog Cardiovasc Dis 1994; 36:343-62. [PMID: 8140249 DOI: 10.1016/s0033-0620(05)80026-x] [Citation(s) in RCA: 26] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- B H Strauss
- Thoraxcenter, Erasmus University, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Foley DP, Escaned J, Strauss BH, di Mario C, Haase J, Keane D, Hermans WR, Rensing BJ, de Feyter PJ, Serruys PW. Quantitative coronary angiography (QCA) in interventional cardiology: clinical application of QCA measurements. Prog Cardiovasc Dis 1994; 36:363-84. [PMID: 8140250 DOI: 10.1016/s0033-0620(05)80027-1] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- D P Foley
- Catheterization Laboratory, Erasmus University, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
|
18
|
Hearn JA, King SB, Douglas JS, Carlin SF, Lembo NJ, Ghazzal ZM. Clinical and angiographic outcomes after coronary artery stenting for acute or threatened closure after percutaneous transluminal coronary angioplasty. Initial results with a balloon-expandable, stainless steel design. Circulation 1993; 88:2086-96. [PMID: 8222102 DOI: 10.1161/01.cir.88.5.2086] [Citation(s) in RCA: 95] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
BACKGROUND Acute occlusion after balloon coronary angioplasty is associated with an increased risk of angina, emergency coronary artery bypass grafting (CABG), myocardial infarction (MI), and death. Stents offer a way of restoring patency and avoiding these complications. METHODS AND RESULTS One hundred sixteen patients underwent attempted stent placement for imminent or total acute closure after PTCA. In 103 patients (110 stents, 105 procedures) the stent was successfully deployed (89%). Angiographic success (final diameter stenosis of < 50%) was achieved in 94 placements (85%). Seventy-one phase 2 procedures (CABG optional, n = 96; phase 1, CABG required, n = 9) were angiographically successful without complications of death, Q-wave myocardial infarction, or CABG (clinical success 74%). Stent placement was associated with resolution of ST-segment deviation and angina in 84% of patients. Five deaths and 5 Q-wave MIs occurred during hospitalization. Two deaths were related to pulmonary insufficiency from chronic lung disease and one patient died after rescue stent placement for left main coronary artery occlusion during routine angiography. Another patient died after CABG was followed by right ventricular MI. The last death occurred in an elderly patient who suffered a stroke while on intravenous heparin. During hospitalization nine patients developed reocclusion after stent placement (8.6% of procedures) and six had repeat PTCA. CABG was performed after 29 stent procedures (28%). The first nine patients underwent CABG as a mandate of the phase 1 protocol. In addition, nine patients had CABG after stenting with a good angiographic result but with a large amount of myocardium at risk. Clinical follow-up was obtained in all patients at a median of 14 months (range, 2 to 43). There were three late deaths (3%), two Q-wave myocardial infarctions (2%), 16 repeat PTCAs (16%), and 15 CABG procedures (15%). Angiographic restenosis (percent diameter > or = 50%) using caliper measurements was found in 30 of 57 patients (53%) at a median of 4 months (93% of patients eligible). A total of 41 procedures were successful and unaccompanied by death, emergency or elective coronary artery bypass grafting, or angiographic restenosis in follow-up. Restenosis and/or clinical events (death, MI, CABG, repeat PTCA) were associated with non-Q MI, hypertension, diabetes, left circumflex coronary artery stenting, saphenous vein graft stenting, smaller caliber artery stenting, higher balloon to artery ratios, and shorter inflation times. CONCLUSIONS Coronary artery stenting for acute closure after PTCA relieves myocardial ischemia and provides an alternate means of treatment. This series includes early learning curve experience; 70% (67 of 96) of patients were spared emergency coronary artery bypass graft surgery when this adverse outcome occurred. Certain clinical and angiographic subsets are at increased risk for restenosis and future cardiac events.
Collapse
Affiliation(s)
- J A Hearn
- Andreas Gruentzig Cardiovascular Center, Department of Internal Medicine, Emory University School of Medicine, Atlanta, Ga
| | | | | | | | | | | |
Collapse
|
19
|
|
20
|
Haude M, Erbel R, Issa H, Meyer J. Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents. J Am Coll Cardiol 1993; 21:26-34. [PMID: 8417068 DOI: 10.1016/0735-1097(93)90713-b] [Citation(s) in RCA: 147] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
OBJECTIVES The purpose of this study was to measure elastic recoil from sequential angiograms after balloon angioplasty and after implantation of a balloon-expandable Palmaz-Schatz stent in the same patient, and to compare the results with the late angiographic outcome. BACKGROUND The immediate result of coronary balloon angioplasty is influenced by plastic deformation, primarily of the atherosclerotic plaque, and by elastic recoil, primarily of the less or nondiseased vessel circumference. METHODS The extent of elastic recoil was measured quantitatively as the difference between maximal balloon size and the resulting vessel diameter or cross-sectional area. RESULTS Analysis was performed in 60 patients who received a single stent for late restenosis after initially successful coronary balloon angioplasty. Minimal lumen diameter (minimal cross-sectional area) was 0.98 +/- 0.43 mm (0.97 +/- 0.67 mm2) before balloon angioplasty, 2.06 +/- 0.36 mm (3.68 +/- 1.17 mm2) after angioplasty (both p < 0.001 vs. values before angioplasty) and 2.98 +/- 0.26 mm (7.12 +/- 1.28 mm2) after stenting (both p < 0.001 vs. postangioplasty results). No significant changes in vessel reference diameters or areas were measured. Mean balloon/artery ratios were similar in both procedures, ranging from 0.93 to 0.96. The calculated mean elastic recoil was 0.98 +/- 0.50 mm in diameter (31%) and 3.67 +/- 2.05 mm2 in area (48%) after balloon angioplasty compared with 0.10 +/- 0.07 mm (3.5%) and 0.38 +/- 0.36 mm2 (5.1%) after stenting. Increasing balloon sizes induced increased vessel stretch, which was followed by increased elastic recoil in the angioplasty group in contrast to the stenting group. Short, noncalcified and eccentric lesions tend to be associated with increased recoil after balloon angioplasty. Overdilation or underdilation in one of the procedures, changes in postprocedural vasomotion or postprocedural thrombus formation was not responsible for this outcome. After 6 months mean minimal lumen diameter was 2.39 +/- 0.58 mm, suggesting a mean hyperplasia of 0.59 +/- 0.51 mm. Twelve patients (20%) had a follow-up diameter that was equal to or less than the mean postangioplasty result and eight patients (14%) had a diameter stenosis of > 50%. CONCLUSIONS The implantation of a Palmaz-Schatz stent almost completely eliminates the decrease in vessel dimensions caused by elastic recoil and therefore diminishes the impact of hyperplasia and reduces the rate of restenosis.
Collapse
Affiliation(s)
- M Haude
- 2nd Medical Clinic, Johannes Gutenberg University, Mainz, Germany
| | | | | | | |
Collapse
|
21
|
Lau KW, Gunnes P, Williams M, Rickards A, Sigwart U. Angiographic restenosis after successful Wallstent stent implantation: an analysis of risk predictors. Am Heart J 1992; 124:1473-7. [PMID: 1462901 DOI: 10.1016/0002-8703(92)90059-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Follow-up angiographic study was performed in 86 patients after initially successful Wallstent stent (Medinvent, Lausanne, Switzerland) implantation between April 1986 and October 1990. The stent angiographic restenosis rate was 16% at a mean of 8 months after stenting despite the inclusion of a substantial number of patients at high risk of restenosis after percutaneous transluminal coronary angioplasty (PTCA). Of a total 15 variables analyzed, only suboptimal stent placement was found to be a significant predictor of stent restenosis. Age; gender; baseline New York Heart Association functional class; previous PTCA; indication for stenting; left ventricular ejection fraction; preangioplasty and immediate postangioplasty diameter stenosis severity; stented vessel site, lesional morphology; number, diameter, and length of stents implanted; and the interval between stenting and follow-up angiographic restudy were not significant risk factors of stent restenosis. Our study suggests that intracoronary stent implantation with the Wallstent may be a useful and promising adjunctive option after PTCA, particularly in patients at high risk of restenosis after PTCA. However, because of the significantly enhanced risk of restenosis after suboptimal stent implantation, we strongly recommend the selection and placement of Wallstent stents that adequately cover the entire length of the dilated coronary segment.
Collapse
Affiliation(s)
- K W Lau
- Royal Brompton National Heart and Lung Hospital, Department of Invasive Cardiology, London, U.K
| | | | | | | | | |
Collapse
|
22
|
de Jaegere PP, Strauss BH, van der Giessen WJ, de Feyter PJ, Serruys PW. Immediate changes in stenosis geometry following stent implantation: comparison between a self-expanding and a balloon-expandable stent. J Interv Cardiol 1992; 5:71-8. [PMID: 10150944 DOI: 10.1111/j.1540-8183.1992.tb00410.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
The immediate changes in stenosis geometry following Wallstent and Wiktor stent implantation in native coronary arteries were compared in 92 patients (46 in each group) using automated edge detection. Patients with comparable baseline stenosis characteristics were selected. Lesions were matched for lesion site, reference diameter, and minimal luminal diameter. In both groups, the stented coronary artery was the left anterior descending artery in 27 patients (59%), the left circumflex artery in four patients (9%), and the right coronary artery in 15 patients (33%). The baseline reference diameter was 2.86 +/- 0.39 mm and 2.87 +/- 0.42 mm in the Wallstent and Wiktor stent study group, respectively (NS). The baseline minimal luminal diameter was identical in both groups (1.13 +/- 0.24 mm). The nominal size (mean +/- SD) of the unconstrained Wallstent was 3.5 +/- 0.3 mm and 3.3 +/- 0.3 mm for the Wiktor stent (P less than 0.05). Both types of stents resulted in a similar increase in minimal luminal diameter immediately following implantation (Wallstent: 2.34 +/- 0.38 mm, Wiktor stent: 2.43 +/- 0.27 mm, NS). Furthermore, there was a similar decrease in diameter stenosis and increase in minimal luminal cross-section area following implantation of both stents. These morphological changes were associated with a normalization of the hemodynamic parameters in both groups. It is concluded that, although the Wallstent and Wiktor stent are different in design and mechanical characteristics, there is a similar immediate improvement in stenosis geometry following implantation of both devices.
Collapse
Affiliation(s)
- P P de Jaegere
- Catheterization Laboratory, Thoraxcenter, Rotterdam, The Netherlands
| | | | | | | | | |
Collapse
|
23
|
de Scheerder IK, Strauss BH, de Feyter PJ, Beatt KJ, Baur LH, Wijns W, Heyndrix GR, Suryapranata H, van den Brand M, Buis B. Stenting of venous bypass grafts: a new treatment modality for patients who are poor candidates for reintervention. Am Heart J 1992; 123:1046-54. [PMID: 1549969 DOI: 10.1016/0002-8703(92)90716-9] [Citation(s) in RCA: 62] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
During a 2-year period, 136 self-expanding Wallstents were implanted in saphenous vein bypass grafts in 69 patients with end-stage coronary artery disease. All patients had severe symptoms and the majority were poor candidates for either repeat surgery or conventional bypass coronary angioplasty because of unfavorable native anatomy, impaired left ventricular function, or a high-risk bypass lesion anatomy for coronary angioplasty. All procedures were technically successful without major complications and a need for emergency bypass surgery. However, during the hospital stay acute thrombotic complications occurred in seven patients (10%) resulting in one death and acute myocardial infarction in five patients and necessitating emergency repeat PTCA in two patients and repeat CABG in four. Twenty-three patients had serious hemorrhagic complications directly related to the rigorous anticoagulation schedule. Two patients died of fatal cerebral bleeding. During follow-up, another five patients died accounting for a total mortality rate of 12%. At late angiographic follow-up (4.9 +/- 3.4 months, n = 53), 25 patients (47%) had a restenosis (greater than or equal to 50% DS) within or immediately adjacent to the stent, necessitating reintervention in 19 patients (PTCA, n = 12; repeat CABG, n = 7). In the group without stent-related restenosis (n = 28), 15 patients had progression of disease in either the native or bypass vessels leading to recurrence of major anginal symptoms within 1 to 24 months. Ten of these patients required further intervention (stent, n = 6; PTCA, n = 3; repeat CABG, n = 1). Stenting in saphenous coronary bypass grafts can be performed safely with excellent immediate angiographic and clinical results.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
24
|
|
25
|
Strauss BH, Serruys PW, Bertrand ME, Puel J, Meier B, Goy JJ, Kappenberger L, Rickards AF, Sigwart U. Quantitative angiographic follow-up of the coronary Wallstent in native vessels and bypass grafts (European experience--March 1986 to March 1990). Am J Cardiol 1992; 69:475-81. [PMID: 1736610 DOI: 10.1016/0002-9149(92)90989-c] [Citation(s) in RCA: 85] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The coronary stent has been investigated as an adjunct to percutaneous transluminal coronary angioplasty to obviate the problems of early occlusion and late restenosis. From March 1986 to March 1990, 265 patients (308 lesions) were implanted with the coronary Wallstent in 6 European centers. For this study, the patients were analyzed according to date of implantation (group 1, March 1986 to January 1988; group 2, February 1988 to March 1990) and vessel type (native arteries versus bypass grafts). Quantitative angiographic follow-up was performed in 82% of the study patients. The early in-hospital occlusion rate in the overall group was 15%. Group 1 patients had a 20% rate in contrast to 12% rate in group 2 (p = not significant [NS]). The early occlusion rate in native vessels and bypass grafts was 19 and 8%, respectively (p = 0.019). Restenosis was determined by 2 criteria (criterion 1, greater than or equal to 0.72 mm loss in minimal luminal diameter from poststent to follow-up; criterion 2, greater than or equal to 50% diameter stenosis at follow-up) within the stent and in the segments immediately proximal and distal to the stent. The restenosis rate with criterion 1 was 43% in the overall group of patients, 35% in group 1 versus 49% in group 2 (p = NS), and 34% in native vessels versus 54% in bypass grafts (p = 0.016). The second criterion was met by 27% of patients in the overall group, 21% in group 1 versus 32% in group 2 (p = NS), and 18% in native vessel versus 39% in bypass grafts (p = 0.005).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- B H Strauss
- Catheterization Laboratory, Thoraxcenter, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Immediate and Long-term Morphologic Changes in Stenosis Geometry after Wiktor™ Stent Implantation in Native Coronary Arteries for Recurrent Stenosis Following Balloon Angioplasty. Report on the First Fifty Consecutive Patients. ACTA ACUST UNITED AC 1992. [DOI: 10.1007/978-94-011-2650-2_13] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
27
|
Serruys P, De Jaegere P, Bertrand M, Kober G, Marquis JF, Piessens J, Uebis R, Valeix B, Wiegand V. Morphologic change in coronary artery stenosis with the Medtronic Wiktor stent: initial results from the core laboratory for quantitative angiography. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS 1991; 24:237-45. [PMID: 1756555 DOI: 10.1002/ccd.1810240403] [Citation(s) in RCA: 47] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The purpose of this study was to assess the early changes in stenosis geometry after implantation of the Medtronic Wiktor stent in human coronary arteries. Morphologic changes were evaluated by quantitative coronary angiography using automated edge detection. The hemodynamic significance of the morphologic changes were assessed by the calculation of the theoretical pressure drop across the dilated and stented stenosis derived from the Poiseuile and turbulent resistances assuming a coronary blood flow of either 0.5, 1, or 3 ml/sec. Fifty patients were studied before and immediately after stent implantation. The stented coronary artery was the left anterior descending artery in 26 patients, the circumflex artery in eight patients, and the right coronary artery in 16 patients. Stent implantation resulted in an additional increase in the minimal luminal cross-sectional area and minimal luminal diameter of the dilated vessel without changing the curvature of the stenosis. Furthermore, there was a significant reduction of the "plaque area." This was associated with a normalization of the calculated resistances to flow and pressure drop across the stenosis. To a minimal extent, recoil (0.1 +/- 0.36 mm) was observed after stent implantation.
Collapse
Affiliation(s)
- P Serruys
- Catheterization Laboratory, Thoraxcenter, Rotterdam, Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Yang XM, Manninen H, Matsi P, Soimakallio S. Percutaneous endovascular stenting: development, investigation and application. Eur J Radiol 1991; 13:161-73. [PMID: 1756741 DOI: 10.1016/0720-048x(91)90022-n] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Percutaneous endovascular stenting (PES), a new and alternative approach of interventional radiologic techniques, has encouraging potentials for management of vascular obstructive diseases. The most important role of PES is to prevent the risk of abrupt closure and to reduce the rate of early and late post-angioplasty restenosis (PARS) of PTA. Because of different working mechanisms, various stents show different advantages and disadvantages. Specific indications of PES are: (1) further compensation for failed PTA, (2) management of complications due to PTA and (3) primary treatment of vascular obstructive diseases. Based on a preliminary comparison with atherectomy, laser angioplasty and PTA, PES seems to provide an advantage for long-term patency of large caliber vessels such as iliac arteries, while more significant problems still exist in PES with small caliber vessels such as femoral-popliteal and coronary arteries. Further comparative clinical research is required to establish the utility of PES among other intraluminal techniques of vascular interventions.
Collapse
Affiliation(s)
- X M Yang
- Department of Clinical Radiology, Kuopio University Central Hospital, Finland
| | | | | | | |
Collapse
|
29
|
Haude M, Erbel R, Straub U, Dietz U, Meyer J. Short and long term results after intracoronary stenting in human coronary arteries: monocentre experience with the balloon-expandable Palmaz-Schatz stent. BRITISH HEART JOURNAL 1991; 66:337-45. [PMID: 1747292 PMCID: PMC1024770 DOI: 10.1136/hrt.66.5.337] [Citation(s) in RCA: 69] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
OBJECTIVE Intracoronary stenting was designed to overcome acute complications after percutaneous transluminal coronary angioplasty and to achieve a reduced rate of restenosis, both of which are major limitations of this well accepted method for treating coronary heart disease. This report describes the experience at one centre with the implantation of balloon-expandable Palmaz-Schatz stents and focuses on device related complications and the short and long term angiographic outcome. DESIGN A retrospective data analysis. PATIENTS Stenting was attempted in 50 patients. Restenosis after an initially successful angioplasty procedure, inadequate postangioplasty results, saphenous coronary bypass stenoses, and bail-out situations were regarded as indications. MAIN OUTCOME MEASURES AND RESULTS In 49 of 50 attempted patients 61 stents (1-4 per patient) were implanted. Delivery problems occurred in three patients and were successfully overcome in two patients. Bail-out situations were successfully managed in 16 patients. Complications included acute thrombus formation within the stent immediately after implantation in one patient, which was successfully treated by thrombolysis. One patient was sent for bypass surgery the day after implantation; another died 10 days after implantation for unknown reasons. Subacute stent thrombosis occurred in seven patients 5-9 days after implantation and was successfully treated by thrombolysis or balloon angioplasty in five patients. Bleeding complications occurred in nine patients, five of whom required blood transfusions. Angiography showed long term vessel patency after 4-6 months in 31 (76%) of the 41 patients who were followed up, restenosis in six (14%), and reocclusion in four (10%). Late restenosis or reocclusion was found in five (15%) of 33 patients with a single stent in contrast to five (63%) of eight patients with multiple stents. CONCLUSIONS Balloon-expandable intracoronary stenting is a feasible method for treating the acute complications of balloon angioplasty. It reduced the rate of restenosis for single stent implantation. Subacute thrombotic events must be regarded as previously unknown and serious complications.
Collapse
Affiliation(s)
- M Haude
- 2nd Medical Clinic, Johannes Gutenberg University, Mainz, Germany
| | | | | | | | | |
Collapse
|
30
|
Bucx JJ, de Scheerder I, Beatt K, van den Brand M, Suryapranata H, de Feyter PJ, Serruys PW. The importance of adequate anticoagulation to prevent early thrombosis after stenting of stenosed venous bypass grafts. Am Heart J 1991; 121:1389-96. [PMID: 2017971 DOI: 10.1016/0002-8703(91)90143-6] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Stent implantation in native coronary arteries may be complicated by acute thrombosis, despite the use of stringent anticoagulation. Thrombotic occlusion of stented venous grafts may occur less frequently, possibly because of the larger caliber of these grafts. We report our experience with 46 stents (Wallstent, Medinvent, Lausanne, Switzerland) implanted in 35 lesions of 24 consecutive patients (mean age 64 years, range 43 to 75). Two overlapping stents were implanted in seven patients, and three overlapping stents were positioned in two. After implantation, activated partial thromboplastin time was maintained at two to three times the control level by intravenous administration of heparin (160 to 550 mg daily) until thrombotest values were reduced 5% to 10% by acenocoumarol. Impending thrombotic occlusion was recognized in two suboptimally anticoagulated patients: patient A after implantation of four stents and patient B after anticoagulation therapy was discontinued because of acute upper gastrointestinal bleeding. Coronary artery bypass grafting was performed successfully in both patients. A third patient had a myocardial infarction on day 7 after stent implantation, in spite of adequate anticoagulation and optimal medical drug therapy. It is concluded that stringent anticoagulation therapy appears mandatory to maintain graft patency after stent implantation.
Collapse
Affiliation(s)
- J J Bucx
- Department of Cardiology, Academic Hospital Dijkzigt, Erasmus University Rotterdam, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
31
|
Serruys PW, Strauss BH, van Beusekom HM, van der Giessen WJ. Stenting of coronary arteries: has a modern Pandora's box been opened? J Am Coll Cardiol 1991; 17:143B-154B. [PMID: 2016472 DOI: 10.1016/0735-1097(91)90951-5] [Citation(s) in RCA: 86] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Interventional cardiology has recently witnessed the growth of several alternatives to percutaneous transluminal angioplasty, including coronary stenting. Although stenting appears to be useful in treating abrupt closure after coronary angioplasty, its effectiveness in limiting the complex processes responsible for late restenosis is much less certain. Pathologic examination of stented human saphenous bypass grafts shows extensive deposits of platelets, fibrin and leukocytes along the stent wires within the 1st week and formation of a neointima of variable thickness after 3 months without evidence of foreign body reaction. The long-term effects of continuous barotrauma induced by the expanded stent remain unknown. It is difficult to assess the relative merits of the new devices, but stenting has several theoretic advantages. It seems less disruptive to the underlying architecture of the vessel wall and enjoys favorable theoretic and effective expansion ratios. Wide-spread clinical acceptance for stenting will depend on demonstrating that its safety, efficacy and cost efficiency are superior to those of balloon angioplasty.
Collapse
Affiliation(s)
- P W Serruys
- Thoraxcenter, Erasmus University, Rotterdam, The Netherlands
| | | | | | | |
Collapse
|
32
|
Haude M, Erbel R, Straub U, Dietz U, Schatz R, Meyer J. Results of intracoronary stents for management of coronary dissection after balloon angioplasty. Am J Cardiol 1991; 67:691-6. [PMID: 2006619 DOI: 10.1016/0002-9149(91)90523-n] [Citation(s) in RCA: 119] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Dissections after coronary balloon angioplasty are risk factors for acute or subacute vessel closures. Intracoronary stenting was developed to avoid these complications by pressing the intimal and medial flaps against the vessel wall, thus reducing the risk of acute thrombosis. A total of 22 stents were implanted into the coronary arteries of 15 patients with dissections after balloon angioplasty causing angina pectoris or ischemic electrocardiographic changes. Stent delivery was successful in all cases. In 1 patient acute stent thrombosis was documented and treated successfully by thrombolytic therapy. Another patient underwent coronary artery bypass surgery 24 hours later because of persisting angina. Angiograms after 24 hours documented vessel patency in the remaining 14 patients. Late control angiograms after 4 to 6 months were obtained in 12 of 14 patients. Vessel patency without significant restenosis was observed in 8 patients, restenosis in 3 and reocclusion in 1 patient. All 3 patients with multiple stent implantation had restenosis (n = 2) or reocclusion (n = 1), compared with 1 patient with single stent implantation. Thus, intracoronary stenting appears to be a secure and effective method of handling bailout situations caused by dissection after balloon angioplasty, with good long-term results when only a single stent is implanted.
Collapse
Affiliation(s)
- M Haude
- Second Medical Clinic, Johannes Gutenberg University, Mainz, Germany
| | | | | | | | | | | |
Collapse
|
33
|
Strauss BH, Juilliere Y, Rensing BJ, Reiber JH, Serruys PW. Edge detection versus densitometry for assessing coronary stenting quantitatively. Am J Cardiol 1991; 67:484-90. [PMID: 1998279 DOI: 10.1016/0002-9149(91)90008-9] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The optimal method used to analyze quantitatively the immediate angiographic results of coronary stenting in the coronary arteries has not been studied. Accordingly, minimal luminal cross-sectional area was determined by 2 methods, edge detection and densitometry, in 19 patients who underwent percutaneous transluminal coronary angioplasty (PTCA) and then coronary stent implantation for symptomatic coronary stenoses. The correlation coefficient, 0.73 before angioplasty, decreased to 0.59 after coronary angioplasty and then increased to 0.83 after stent implantation. The mean differences between edge detection and densitometric determinations of minimal luminal cross-sectional area were 0.31 +/- 0.51 mm2 before PTCA, -0.38 +/- 1.22 mm2 after angioplasty and 0.35 +/- 0.79 mm2 after coronary stenting. It is concluded that, although the correlation and variability in the measurement of minimal luminal cross-sectional area between edge detection and densitometry deteriorate after PTCA, they are improved after stenting, probably because of smoothing of the vessel contours by the stent and remodeling of the stented segment into a more circular configuration. Therefore, in the stented coronary artery, edge detection and densitometry are equally acceptable methods of analysis.
Collapse
Affiliation(s)
- B H Strauss
- Catheterization Laboratory, Thoraxcenter, Erasmus University, Rotterdam, The Netherlands
| | | | | | | | | |
Collapse
|
34
|
|
35
|
Serruys PW, Strauss BH, Beatt KJ, Bertrand ME, Puel J, Rickards AF, Meier B, Goy JJ, Vogt P, Kappenberger L. Angiographic follow-up after placement of a self-expanding coronary-artery stent. N Engl J Med 1991; 324:13-7. [PMID: 1984159 DOI: 10.1056/nejm199101033240103] [Citation(s) in RCA: 505] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
BACKGROUND The placement of stents in coronary arteries after coronary angioplasty has been investigated as a way of treating abrupt coronary-artery occlusion related to the angioplasty and of reducing the late intimal hyperplasia responsible for gradual restenosis of the dilated lesion. METHODS From March 1986 to January 1988, we implanted 117 self-expanding, stainless-steel endovascular stents (Wallstent) in the native coronary arteries (94 stents) or saphenous-vein bypass grafts (23 stents) of 105 patients. Angiograms were obtained immediately before and after placement of the stent and at follow-up at least one month later (unless symptoms required angiography sooner). The mortality after one year was 7.6 percent (8 patients). Follow-up angiograms (after a mean [+/- SD] of 5.7 +/- 4.4 months) were obtained in 95 patients with 105 stents and were analyzed quantitatively by a computer-assisted system of cardiovascular angiographic analysis. The 10 patients without follow-up angiograms included 4 who died. RESULTS Complete occlusion occurred in 27 stents in 25 patients (24 percent); 21 occlusions were documented within the first 14 days after implantation. Overall, immediately after placement of the stent there was a significant increase in the minimal luminal diameter and a significant decrease in the percentage of the diameter with stenosis (changing from a mean [+/- SD] of 1.88 +/- 0.43 to 2.48 +/- 0.51 mm and from 37 +/- 12 to 21 +/- 10 percent, respectively; P less than 0.0001). Later, however, there was a significant decrease in the minimal luminal diameter and a significant increase in the stenosis of the segment with the stent (1.68 +/- 1.78 mm and 48 +/- 34 percent at follow-up). Significant restenosis, as indicated by a reduction of 0.72 mm in the minimal luminal diameter or by an increase in the percentage of stenosis to greater than or equal to 50 percent, occurred in 32 percent and 14 percent of patent stents, respectively. CONCLUSIONS Early occlusion remains an important limitation of this coronary-artery stent. Even when the early effects are beneficial, there are frequently late occlusions or restenosis. The place of this form of treatment for coronary artery disease remains to be determined.
Collapse
Affiliation(s)
- P W Serruys
- Catheterization Laboratory, Erasmus University, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
|
37
|
Schwartz RS, Murphy JG, Edwards WD, Camrud AR, Vliestra RE, Holmes DR. Restenosis after balloon angioplasty. A practical proliferative model in porcine coronary arteries. Circulation 1990; 82:2190-200. [PMID: 2146991 DOI: 10.1161/01.cir.82.6.2190] [Citation(s) in RCA: 272] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
A model of proliferative human restenosis was developed in domestic pigs by using deep injury to the coronary arterial media. Metal wire coils were delivered percutaneously to the coronary arteries of 11 pigs with an oversized, high-pressure (14 atm) balloon and were left in place for times ranging from 28 to 70 days. During placement, the balloon expanded the coils and delivered them securely within the arterial lumen. Light microscopic examination of the vessels confirmed fracture of the internal elastic lamina by the coil. An extensive proliferative response occurred in 10 of the 11 pigs and was associated with a luminal area narrowing of at least 50% in all but one pig. The histopathologic features of the proliferative response were identical to those observed in human cases of restenosis after angioplasty. Immunohistochemical studies confirmed the prominence of smooth muscle cells in the proliferative tissue. A similar response was obtained in two of five porcine coronary arteries in which balloon inflation only was performed, without coil implant. This model is practical and inexpensive and closely mimics the proliferative portion of human restenosis both grossly and microscopically. Thus, it may be useful for understanding human restenosis and for testing therapies aimed at preventing restenosis after balloon angioplasty or other coronary interventional procedures.
Collapse
Affiliation(s)
- R S Schwartz
- Division of Cardiovascular Diseases and Internal Medicine, Mayo Graduate School of Medicine, Mayo Clinic and Foundation, Rochester, Minn 55905
| | | | | | | | | | | |
Collapse
|
38
|
Haude M, Erbel R, Straub U, Dietz U, Schatz R, Meyer J. Coronary stent implantation in acute vessel closure 48 hours after an unsatisfactory coronary angioplasty. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS 1990; 21:263-5. [PMID: 2276200 DOI: 10.1002/ccd.1810210413] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
We report the implantation of a balloon-expandable stent in a patient with acute vessel closure in the state of evolving myocardial infarction following 48 hr after unsatisfactory coronary angioplasty. The stent was implanted after successful recanalization of an occluded left anterior descending artery, with repeated unsatisfactory results of balloon angioplasty. Adjunct thrombolytic therapy was contraindicated. No residual stenosis was documented in immediate control angiograms, or after 24 hr, 3 weeks, and 4 months.
Collapse
Affiliation(s)
- M Haude
- 2nd Medical Clinic, Johannes Gutenberg University, Mainz, Federal Republic of Germany
| | | | | | | | | | | |
Collapse
|
39
|
BURGER WOLFRAM, HARTMANN ANDREAS, KANDYBA JÖRG, KEUL HANSGEORG, SIEVERT HORST, NIEMÖLLER ELISABETH, SCHNEIDER MARKWARD, KOBER GISBERT. Angiographic and Histologic Course after Implantation of Balloon Expandable Intravascular Stents in Miniswine Coronary Arteries: Short- and Mid-Term Observations. J Interv Cardiol 1990. [DOI: 10.1111/j.1540-8183.1990.tb00966.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
40
|
van der Giessen WJ, Serruys PW, van Woerkens LJ, Beatt KJ, Visser WJ, Jongkind JF, van Bremen RH, Ridderhof E, van Loon H, Soei LK. Arterial stenting with self-expandable and balloon-expandable endoprostheses. INTERNATIONAL JOURNAL OF CARDIAC IMAGING 1990; 5:163-71. [PMID: 2230294 DOI: 10.1007/bf01833985] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Coronary angioplasty is complicated by acute occlusion (within 24 hours) and late restenosis (within 6 months) in 2-5% and 20-40% of the cases, respectively. Vascular endoprostheses (stents) may provide the cardiologist with a solution to some of these complications. Several stent-devices are now available for experimental and clinical evaluation. In this study we describe our experience with two metallic stents in normal arteries of swine. Self-expandable, stainless steel stents (3.5 mm diameter) were implanted in 17 peripheral arteries, eight of which were deendothelialized by prior balloon angioplasty. Following implantation, the animals received antithrombotic therapy with acenocoumarol and aspirin (8 stents), or aspirin alone (9 stents). After 1 week repeat angiography was performed, which showed patency of all stented arteries. Microscopy showed complete covering by neointima, 80 microns in thickness. This self-expandable stent (SES) and a balloon-expandable stent (BES), constructed of tantalum, were implanted in normal coronary arteries. SES (3.0 and 3.5 mm) receiving animals were treated with coumadines (10 stents) or received no antithrombotic treatment (16 stents) after implantation. BES receiving animals were also not treated (10 stents). Three untreated animals with SES died suddenly within 48 hours. Postmortem examination showed partial or complete thrombosis of all six stents in these animals, resulting in a patency rate of 62% after 1 week. All animals with SES, which were treated with coumadines, and all animals with BES (untreated) had patent stents after one week. It is concluded that SES implanted in normal coronary arteries of pigs, which do not receive additional antithrombotic treatment, show a 38% occlusion rate within 48 hours, but show 100% patency after 1 week, when the animals are treated with coumadines. BES implanted in normal coronary arteries of pigs, which do not receive antithrombotic drugs, are 100% patent after 1 week.
Collapse
|
41
|
|
42
|
Urban P, Sigwart U, Golf S, Kaufmann U, Sadeghi H, Kappenberger L. Intravascular stenting for stenosis of aortocoronary venous bypass grafts. J Am Coll Cardiol 1989; 13:1085-91. [PMID: 2784454 DOI: 10.1016/0735-1097(89)90265-9] [Citation(s) in RCA: 80] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
To test the ability of endoluminal stents to prevent saphenous vein graft restenosis after balloon angioplasty, 13 patients with angina and previous coronary bypass surgery underwent implantation of one or more stents into 14 stenosed grafts. Implantation was technically successful in all cases and there were no major in-hospital complications. During a median follow-up interval of 7 months (range 2 to 26), 10 patients (77%) underwent follow-up angiography. Seven patients remained asymptomatic or in improved condition without further intervention; three patients had further angioplasty with stent implantation for a new stenosis in the same graft. Two patients (20%) developed within-stent restenosis. There was one death from progressive congestive heart failure 7 months after implantation. No patient had a myocardial infarction or needed surgical revascularization during the follow-up period. In selected cases, stent implantation appears to be a promising new technique that may decrease the incidence of restenosis after balloon angioplasty in venous bypass grafts. The rate of complications is low. Further experience and longer follow-up will be needed before definite recommendations can be made about its use.
Collapse
Affiliation(s)
- P Urban
- Department of Internal Medicine, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
| | | | | | | | | | | |
Collapse
|
43
|
KAUFMANN U, SIGWART U. Resolution of Residual Pressure Gradients After Angioplasty by Stenting. J Interv Cardiol 1989. [DOI: 10.1111/j.1540-8183.1989.tb00748.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|