• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4598322)   Today's Articles (647)   Subscriber (49355)
For: Ellenbogen KA, Lu B, Kapadia K, Wood M, Valenta H. Usefulness of right ventricular pulse pressure as a potential sensor for hemodynamically unstable ventricular tachycardia. Am J Cardiol 1990;65:1105-11. [PMID: 2330895 DOI: 10.1016/0002-9149(90)90322-r] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Number Cited by Other Article(s)
1
Kaszala K, Ellenbogen KA. Device sensing: sensors and algorithms for pacemakers and implantable cardioverter defibrillators. Circulation 2010;122:1328-40. [PMID: 20876446 DOI: 10.1161/circulationaha.109.919704] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
2
PETRUCCI ETTORE, BRAGA SIMONASARZI, BALIAN VRUYR, PEDRETTI ROBERTOF. Right Ventricular Pressure Changes During Induced Ventricular Tachycardias Predict Clinical Symptoms of Cerebral Hypoperfusion: Implications for a Reduction of Unnecessary, Painful ICD Shocks. J Cardiovasc Electrophysiol 2009;20:299-306. [DOI: 10.1111/j.1540-8167.2008.01306.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
3
Gillberg J. Detection of cardiac tachyarrhythmias in implantable devices. J Electrocardiol 2007;40:S123-8. [DOI: 10.1016/j.jelectrocard.2007.05.031] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2007] [Accepted: 05/30/2007] [Indexed: 11/16/2022]
4
Compton AJ, Bolouri H, Nathan AW. Arrhythmia recognition strategies and hardware decisions for the implantable cardioverter-defibrillator--a review. Med Eng Phys 1995;17:96-103. [PMID: 7735649 DOI: 10.1016/1350-4533(95)91879-l] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
5
Witherell CL. Cardiac Rhythm Control Devices. Crit Care Nurs Clin North Am 1994. [DOI: 10.1016/s0899-5885(18)30510-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
6
Astridge PS, Kaye GC, Perrins EJ. Current approaches and future developments in automatic tachycardia detection and diagnosis. BRITISH HEART JOURNAL 1993;70:106-10. [PMID: 8038016 PMCID: PMC1025266 DOI: 10.1136/hrt.70.2.106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
7
Lau CP. The range of sensors and algorithms used in rate adaptive cardiac pacing. Pacing Clin Electrophysiol 1992;15:1177-211. [PMID: 1381086 DOI: 10.1111/j.1540-8159.1992.tb03121.x] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
8
Ellenbogen KA, Wood MA, Kapadia K, Lu B, Valenta H. Short-term reproducibility over time of right ventricular pulse pressure as a potential hemodynamic sensor for ventricular tachyarrhythmias. Pacing Clin Electrophysiol 1992;15:971-4. [PMID: 1378606 DOI: 10.1111/j.1540-8159.1992.tb03088.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
9
Damiano RJ. Implantable cardioverter defibrillators: current status and future directions. J Card Surg 1992;7:36-57. [PMID: 1554977 DOI: 10.1111/j.1540-8191.1992.tb00774.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
10
Kapadia KA, Wood MA, Lu B, Valenta H, Ellenbogen KA. A prospective study of changes in right ventricular dP/dt during ventricular tachycardia. Pacing Clin Electrophysiol 1991;14:1098-104. [PMID: 1715546 DOI: 10.1111/j.1540-8159.1991.tb02840.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
11
Cohen TJ, Liem LB. Biosensor applications to antitachycardia devices. Pacing Clin Electrophysiol 1991;14:322-8. [PMID: 1706846 DOI: 10.1111/j.1540-8159.1991.tb05115.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA