1
|
Haq N, Alanazi FK, Salem-Bekhit MM, Rabea S, Alam P, Alsarra IA, Shakeel F. Greenness estimation of chromatographic assay for the determination of anthracycline-based antitumor drug in bacterial ghost matrix of Salmonella typhimurium. SUSTAINABLE CHEMISTRY AND PHARMACY 2022; 26:100642. [DOI: 10.1016/j.scp.2022.100642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/22/2023]
|
2
|
Estimation of Anti-neoplastic Drug Doxorubicin in Bacterial Ghost Matrix by New “Environmentally Benign” RP-HPLC Method: A Step Towards Sustainable Development of Pharmaceutical Industry. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING 2017. [DOI: 10.1007/s13369-017-2664-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
3
|
KOZIOLOVA E, JANOUSKOVA O, CHYTIL P, STUDENOVSKY M, KOSTKA L, ETRYCH T. Nanotherapeutics With Anthracyclines: Methods of Determination and Quantification of Anthracyclines in Biological Samples. Physiol Res 2015; 64:S1-10. [DOI: 10.33549/physiolres.933140] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Anthracyclines, e.g. doxorubicin, pirarubicin, are widely used as cytostatic agents in the polymer nanotherapeutics designed for the highly effective antitumor therapy with reduced side effects. However, their precise dosage scheme needs to be optimized, which requires an accurate method for their quantification on the cellular level in vitro during nanocarrier development and in body fluids and tissues during testing in vivo. Various methods detecting the anthracycline content in biological samples have already been designed. Most of them are highly demanding and they differ in exactness and reproducibility. The cellular uptake and localization is predominantly observed and determined by microscopy techniques, the anthracycline content is usually quantified by chromatographic analysis using fluorescence detection. We reviewed and compared published methods concerning the detection of anthracycline nanocarriers.
Collapse
Affiliation(s)
- E. KOZIOLOVA
- Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Prague, Czech Republic
| | | | | | | | | | | |
Collapse
|
4
|
Simultaneous measurement of doxorubicin and reduced metabolite doxorubicinol by UHPLC–MS/MS in human plasma of HCC patients treated with TACE. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 915-916:71-8. [DOI: 10.1016/j.jchromb.2012.12.012] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2012] [Revised: 12/05/2012] [Accepted: 12/16/2012] [Indexed: 11/18/2022]
|
5
|
Maudens KE, Stove CP, Lambert WE. Quantitative liquid chromatographic analysis of anthracyclines in biological fluids. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:2471-86. [PMID: 21840776 DOI: 10.1016/j.jchromb.2011.07.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2011] [Revised: 07/01/2011] [Accepted: 07/07/2011] [Indexed: 10/18/2022]
Abstract
Anthracyclines are amongst the most widely used drugs in oncology, being part of the treatment regimen in most patients receiving systemic chemotherapy. This review provides a comprehensive summary of the sample preparation techniques and chromatographic methods that have been developed during the last two decades for the analysis of the 4 most administered anthracyclines, doxorubicin, epirubicin, daunorubicin and idarubicin in plasma, serum, saliva or urine, within the context of clinical and pharmacokinetic studies or for assessing occupational exposure. Following deproteinization, liquid-liquid extraction, solid phase extraction or a combination of these techniques, the vast majority of methods utilizes reversed-phase C18 stationary phases for liquid chromatographic separation, followed by fluorescence detection, or, more recently, tandem mass spectrometric detection. Some pros and cons of the different techniques are addressed, in addition to potential pitfalls that may be encountered in the analysis of this class of compounds.
Collapse
Affiliation(s)
- Kristof E Maudens
- Toxicological Centre, Department of Pharmaceutical Sciences, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk-Antwerp, Belgium
| | | | | |
Collapse
|
6
|
Jelińska A, Zając M, Cielecka-Piontek J, Gląb K, Tomaszewicz B, Krause A, Oszczapowicz I, Wąsowska M. Validation of a Stability Indicating LC-UV Method for [(N-Morpholine)methylene]daunorubicin Hydrochloride. Chromatographia 2008. [DOI: 10.1365/s10337-007-0512-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
7
|
Emara S, Morita I, Tamura K, Razee S, Masujima T, Mohamed HA, Gizawy SME, Rabbat NAE. Utility of Ion-Pair Chromatography for Analysis of Some Anthracyclines in Plasma and Urine. J LIQ CHROMATOGR R T 2006. [DOI: 10.1080/10826079808005850] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Samy Emara
- a Faculty of Pharmacy Assiut University , Assiut, Egypt
| | - Ikue Morita
- b Institute of Pharmaceutical Sciences School of Medicine , Hiroshima University , 1-2-3 Kasumi, Minami-ku, Hiroshima, 734, Japan
| | - Keiko Tamura
- b Institute of Pharmaceutical Sciences School of Medicine , Hiroshima University , 1-2-3 Kasumi, Minami-ku, Hiroshima, 734, Japan
| | - Saeid Razee
- b Institute of Pharmaceutical Sciences School of Medicine , Hiroshima University , 1-2-3 Kasumi, Minami-ku, Hiroshima, 734, Japan
| | - Tsutomu Masujima
- b Institute of Pharmaceutical Sciences School of Medicine , Hiroshima University , 1-2-3 Kasumi, Minami-ku, Hiroshima, 734, Japan
| | | | | | | |
Collapse
|
8
|
Badea I, Lazăr L, Moja D, Nicolescu D, Tudose A. A HPLC method for the simultaneous determination of seven anthracyclines. J Pharm Biomed Anal 2005; 39:305-9. [PMID: 15935598 DOI: 10.1016/j.jpba.2005.03.039] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2004] [Revised: 02/24/2005] [Accepted: 03/02/2005] [Indexed: 11/26/2022]
Abstract
A HPLC method has been developed for the determination of epirubicin hydrochloride, doxorubicin hydrochloride and idarubicin hydrochloride in the presence of four other anthracyclines. This method ensures the rapid determination of seven anthracyclines. It is simple and rapid and does not require any preliminary treatment of the sample. The method was fully validated.
Collapse
Affiliation(s)
- Irinel Badea
- Department of Analytical Chemistry, University of Bucharest, Romania.
| | | | | | | | | |
Collapse
|
9
|
Chen CL, Thoen KK, Uckun FM. High-performance liquid chromatographic methods for the determination of topoisomerase II inhibitors. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2001; 764:81-119. [PMID: 11817045 DOI: 10.1016/s0378-4347(01)00314-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Various methods for separating eleven different types of topoisomerase II (TOPO-2) inhibitors, including epipodophyllotoxins, anthracyclines, anthracenediones, anthrapyrazoles, anthracenebishydrazones, indole derivatives, aminoacridines, benzisoquinolinediones, isoflavones, bisdioxopiperazines and thiobarbituric acids, are summarized. Proper sample preparation and storage is critical to the successful analysis of some TOPO-2 inhibitors due to difficulties associated with adsorption, instability and complex biological components. Solid-phase and liquid-liquid extractions are widely used to separate TOPO-2 inhibitors from biological samples, although simple deproteinization followed by direct analysis of the supernatant is preferable to extraction based on its speed and simplicity. High-performance liquid chromatography (HPLC) is the favored method for the bioanalysis of TOPO-2 inhibitors. UV or diode array detection is generally employed for early pharmacokinetic studies, while fluorescence or electrochemical detection is used more frequently for analytes with fluorescent or oxidative-reductive properties. For analyses requiring highly sensitive and/or specific detection, electrospray mass spectrometry (ESI-MS or ESI-MS-MS) provides a suitable alternative. A comprehensive compilation of the HPLC techniques currently used to separate TOPO-2 inhibitors will aid the future development of analytical methods for new TOPO-2 inhibitors.
Collapse
Affiliation(s)
- C L Chen
- Department of Pharmaceutical Sciences, Parker Hughes Cancer Center, Parker Hughes Institute, St. Paul, MN 55113, USA
| | | | | |
Collapse
|
10
|
Lachâtre F, Marquet P, Ragot S, Gaulier JM, Cardot P, Dupuy JL. Simultaneous determination of four anthracyclines and three metabolites in human serum by liquid chromatography-electrospray mass spectrometry. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2000; 738:281-91. [PMID: 10718646 DOI: 10.1016/s0378-4347(99)00529-0] [Citation(s) in RCA: 78] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
A sensitive and very specific method, using liquid chromatography-electrospray mass spectrometry (LC-ES-MS), was developed for the determination of epirubicin, doxorubicin, daunorubicin, idarubicin and the respective active metabolites of the last three, namely doxorubicinol, daunorubicinol and idarubicinol in human serum, using aclarubicin as internal standard. Once thawed, 0.5-ml serum samples underwent an automated solid-phase extraction, using C18 Bond Elut cartridges (Varian) and a Zymark Rapid-Trace robot. After elution of the compounds with chloroform-2-propanol (4:1, v/v) and evaporation, the residue was reconstituted with a mixture of 5 mM ammonium formate buffer (pH 4.5)-acetonitrile (60:40, v/v). The chromatographic separation was performed using a Symmetry C18, 3.5 microm (150 x 1 mm I.D.) reversed-phase column, and a mixture of 5 mM ammonium formate buffer (pH 3)-acetonitrile (70:30, v/v) as mobile phase, delivered at 50 microl/min. The compounds were detected in the selected ion monitoring mode using, as quantitation ions, m/z 291 for idarubicin and idarubicinol, m/z 321 for daunorubicin and daunorubicinol, m/z 361 for epirubicin and doxorubicin, m/z 363 for doxorubicinol and m/z 812 for aclarubicin (I.S.). Extraction recovery was between 71 and 105% depending on compounds and concentration. The limit of detection was 0.5 ng/ml for daunorubicin and idarubicinol, 1 ng/ml for doxorubicin, epirubicin and idarubicin, 2 ng/ml for daunorubicinol and 2.5 ng/ml for doxorubicinol. The limit of quantitation (LOQ) was 2.5 ng/ml for doxorubicin, epirubicin and daunorubicinol, and 5 ng/ml for daunorubicin, idarubicin, doxorubicinol and idarubicinol. Linearity was verified from these LOQs up to 2000 ng/ml for the parent drugs (r > or = 0.992) and 200 ng/ml for the active metabolites (r > or = 0.985). Above LOQ, the within-day and between-day precision relative standard deviation values were all less than 15%. This assay was applied successfully to the analysis of human serum samples collected in patients administered doxorubicin or daunorubicin intravenously. This method is rapid, reliable, allows an easy sample preparation owing to the automated extraction and a high selectivity owing to MS detection.
Collapse
Affiliation(s)
- F Lachâtre
- Department of Pharmacology and Toxicology, University Hospital, Limoges, France
| | | | | | | | | | | |
Collapse
|
11
|
Abstract
Doxorubicin is one of the most potent anti-tumor agents generally used in the treatment of bone cancer. A simple and sensitive HPLC method was developed and validated for the assay of doxorubicin. The method used a C18 Luna microbore column (50 x 1 mm) with a fluorescent detector (505 nm Ex. and 550 nm Em.). The mobile phase consisted of water-acetonitrile-acetic acid (80:19:1, v/v/v, pH 3.0) and the flow rate was 0.1 ml min(-1). Daunomycin was used as the internal standard. This isocratic system required a 10-min run-time, giving a detection limit of 0.02 ng (0.035 pmol per injection). Standard curves were linear over the concentration range of 0.01-0.1 microg ml(-1). Relative standard deviations (R.S.D.) for the within-day, day-to-day precision, and the accuracy measurement for the assay were less than 4.0, 3.2, and 4.1%, respectively. This HPLC method was used to study the in vitro release characteristics of doxorubicin from implantable drug delivery system.
Collapse
Affiliation(s)
- P Zhao
- Department of Pharmaceutical and Administrative Sciences, School of Pharmacy and Allied Health Professions, Creighton University, Omaha, NE 68178, USA
| | | |
Collapse
|