1
|
Rotman OM, Kovarovic B, Chiu WC, Bianchi M, Marom G, Slepian MJ, Bluestein D. Novel Polymeric Valve for Transcatheter Aortic Valve Replacement Applications: In Vitro Hemodynamic Study. Ann Biomed Eng 2018; 47:113-125. [PMID: 30194551 DOI: 10.1007/s10439-018-02119-7] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Accepted: 08/17/2018] [Indexed: 11/30/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) is a minimally-invasive approach for treating severe aortic stenosis. All clinically-used TAVR valves to date utilize chemically-fixed xenograft as the leaflet material. Inherent limitation of the tissue (e.g., calcific degeneration) motivates the search for alternative leaflet material. Here we introduce a novel polymeric TAVR valve that was designed to address the limitations of tissue-valves. In this study, we experimentally evaluated the hemodynamic performance of the valve and compared its performance to clinically-used valves: a gold standard surgical tissue valve, and a TAVR valve. Our comparative testing protocols included: (i) baseline hydrodynamics (ISO:5840-3), (ii) complementary patient-specific hydrodynamics in a dedicated system, and (iii) thrombogenicity. The patient-specific testing system facilitated comparing TAVR valves performance under more realistic conditions. Baseline hydrodynamics results at CO 4-7 L/min showed superior effective orifice area (EOA) for the polymer valve, most-notably as compared to the reference TAVR valve. Regurgitation fraction was higher in the polymeric valve, but within the ISO minimum requirements. Thrombogenicity trends followed the EOA results with the polymeric valve being the least thrombogenic, and clinical TAVR being the most. Hemodynamic-wise, the results strongly indicate that our polymeric TAVR valve can outperform tissue valves.
Collapse
Affiliation(s)
- Oren M Rotman
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA
| | - Brandon Kovarovic
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA
| | - Wei-Che Chiu
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA
| | - Matteo Bianchi
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA
| | - Gil Marom
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA.,School of Mechanical Engineering, Tel Aviv University, 6997801, Tel Aviv, Israel
| | - Marvin J Slepian
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8151, USA.
| |
Collapse
|
2
|
Gelsomino S, Morocutti G, Masullo G, Da Col P, Frassani R, Spedicato L, Livi U. Patient‐Prosthesis Mismatch After Small‐Size Stentless Aortic Valve Replacement. J Card Surg 2004; 19:91-7. [PMID: 15016042 DOI: 10.1111/j.0886-0440.2004.04020.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The aim of this study was to determine the occurrence of patient-prosthesis mismatch (P-PM) after aortic valve replacement (AVR) with a small-size Cryolife O'Brien (CLOB) bioprosthesis and to evaluate its clinical and hemodynamic implications. METHODS Sixty-two patients (mean age 70.9 +/- 5.2 years, 77.8% females), receiving a labeled 21-23 mm CLOB between 1993 and 2000, were retrospectively studied. Effective orifice area (EOA) was calculated by the continuity equation and then indexed to the patient's body surface area (BSA) to obtain the indexed EOA (EOAI). Based on previous observations a mismatch was defined as EOAI <or= 0.85 cm2/m2. RESULTS Twelve patients (20%) at discharge, two (3.3%) at 6 months and none at late controls had an EOAI <or= 0.85 cm2/m2. At ANOVA determinants of mismatch were female sex (p < 0.001), age (p = 0.01), and patient's annulus index (PAI, p < 0.001). Patients with mismatch had higher mean gradients (MG, p = 0.01, and p < 0.001 at discharge and 6 months, respectively) and EOAI correlated with MG at discharge (r2= 0.72, p < 0.001) and 6-month (r2= 0.40, p = 0.001) studies. At 1 year no difference in MG was detected between patients with or without mismatch (p = ns) and EOAI did not correlate with MG (r2= 0.01, p = ns). Midwall fractional shortening did not differ in patients with or without mismatch (p = ns). Patients with an EOAI >or= 0.8 cm/m2 showed an earlier concentric remodeling up to 1 year; no difference was demonstrated at later studies between groups. Survival and clinical status results were not affected by an EOAI <or= 0.85 cm2/m2. CONCLUSIONS After AVR with CLOB mismatch occurred early postoperatively in a small number of patients without clinical repercussions. EOAI, significantly increasing over time, was adequate to BSA in all patients at late controls.
Collapse
Affiliation(s)
- Sandro Gelsomino
- Department of Cardiovascular Sciences, General Hospital "S.Maria della Misericordia", Udine, Italy.
| | | | | | | | | | | | | |
Collapse
|
3
|
Vitale N, Clark SC, Ramsden A, Hasan A, Hilton CJ, Holden MP. Clinical and hemodynamic evaluation of small Perimount aortic valves in patients aged 75 years or older. Ann Thorac Surg 2003; 75:35-9; discussion 40. [PMID: 12537189 DOI: 10.1016/s0003-4975(02)04165-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND There is the potential for iatrogenic aortic stenosis and poor quality of life when small aortic valve bioprostheses are used in elderly patients. The alternative is enlarging the aortic annulus to accommodate larger size prostheses, increasing operative mortality. It was hoped that bovine pericardial valves would improve hemodynamic performance in the smaller valve sizes. METHODS To determine long-term results and in vivo hemodynamic performance of small-size aortic Carpentier-Edwards bovine pericardial valves (Perimount) in elderly patients, we analyzed our follow-up and echocardiographic data from patients 75 years of age or older receiving isolated 19-mm and 21-mm Perimount valves. Ninety-four patients with a mean age of 77 +/- 2.2 years were followed for 12 years. Seventeen patients with 19-mm and 25 patients with 21-mm Perimount valves underwent transthoracic echocardiograms. RESULTS Operative mortality was 6.3% (6 of 94). Twelve-year survival was 82.7%. Freedom from thromboembolism was 86.9% at 12 years. Two patients had anticoagulation-related bleeding. Overall New York Heart Association class decreased from 3 +/- 1 to 1.6 +/- 0.7 at the end of follow-up. Hemodynamic performances were satisfactory in both 19-mm and 21-mm Perimount valves, with low peak and mean transvalvular gradients and good effective orifice areas, orifice area indices, and performance indices. CONCLUSIONS Perimount aortic valve in the small aortic annulus has yielded excellent long-term results and hemodynamic performances. Perimount is a very satisfactory option in elderly patients. Implantation of a Perimount bioprosthesis avoids enlargement of the small aortic annulus, reducing mortality and morbidity associated with this procedure.
Collapse
Affiliation(s)
- Nicola Vitale
- Department of Cardiothoracic Surgery, Freeman Hospital, Newcastle-Upon-Tyne, United Kingdom.
| | | | | | | | | | | |
Collapse
|
4
|
Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol 2000; 36:1131-41. [PMID: 11028462 DOI: 10.1016/s0735-1097(00)00859-7] [Citation(s) in RCA: 428] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Prosthesis-patient mismatch is present when the effective orifice area of the inserted prosthetic valve is less than that of a normal human valve. This is a frequent problem in patients undergoing aortic valve replacement, and its main hemodynamic consequence is the generation of high transvalvular gradients through normally functioning prosthetic valves. The purposes of this report are to present an update on the concept of aortic prosthesis-patient mismatch and to review the present knowledge with regard to its impact on hemodynamic status, functional capacity, morbidity and mortality. Also, we propose a simple approach for the prevention and clinical management of this phenomenon because it can be largely avoided if certain simple factors are taken into consideration before the operation.
Collapse
Affiliation(s)
- P Pibarot
- Quebec Heart Institute/Laval Hospital, Laval University, Sainte-Foy, Canada
| | | |
Collapse
|
5
|
Maslow AD, Haering JM, Heindel S, Mashikian J, Levine R, Douglas P. An evaluation of prosthetic aortic valves using transesophageal echocardiography: the double-envelope technique. Anesth Analg 2000; 91:509-16. [PMID: 10960367 DOI: 10.1097/00000539-200009000-00002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
UNLABELLED The conventional continuity equation uses nonsimultaneous measurements of blood flow velocities through the left ventricular outflow tract and across the aortic valve to calculate aortic valve area (AVA). We have noted that both velocities can be simultaneously obtained from continuous wave (CW) Doppler analysis (double-envelope [DE]). We hypothesize that prosthetic AVA can be calculated by using the DE technique, during transesophageal echocardiography (TEE). Prosthetic AVA was calculated in 41 of 45 patients immediately after aortic valve replacement by using the DE/AVA technique. Left ventricular outflow tract diameter was obtained from an esophageal view, while subvalvular (V(1)) and valvular (V(2)) peak velocities were simultaneously obtained from transgastric views by using CW Doppler. Prosthetic AVA and V(1)/V(2) ratio (Doppler velocity index) were calculated. V(1) was also measured by using pulse wave Doppler, as is conventionally done. Twenty-three Carbomedic (CM) and 18 Carpentier-Edwards (CE) AVA were evaluated. DE/AVAs for CM and CE valves correlated and agreed with that reported by the manufacturer (CM r(2) = 0.91, mean bias -0.25 cm(2) [SD 0.18]; CE r(2) = 0.73, mean bias -0.02 cm(2) [SD 0.27]). Calculated Doppler velocity index values agree with available data (mean bias 0.03 [SD 0.05]). The V(1) obtained by using the DE method was nearly identical to the V(1) obtained by using pulse wave (r(2) = 0.95, mean bias 0.02 m/s [SD 0.04 m/s]). TEE assessment of prosthetic AVA using the DE technique agrees with data reported by the manufacturer. Obtaining subvalvular and valvular velocities from the same CW Doppler trace may simplify the continuity equation and help avoid errors caused by beat-to-beat changes in blood flow. Quantitative prosthetic aortic valve assessment can be performed, on-line, with TEE by using the DE technique. IMPLICATIONS Quantitative assessment of prosthetic aortic valve area can be performed on-line by using transesophageal echocardiography using the double envelope technique.
Collapse
Affiliation(s)
- A D Maslow
- Departments of Anesthesia and Cardiology, Beth Israel-Deaconess Medical Center. Mass General Hospital, Boston, MA, USA.
| | | | | | | | | | | |
Collapse
|
6
|
Maslow AD, Haering JM, Heindel S, Mashikian J, Levine R, Douglas P. An Evaluation of Prosthetic Aortic Valves Using Transesophageal Echocardiography: The Double-Envelope Technique. Anesth Analg 2000. [DOI: 10.1213/00000539-200009000-00002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
7
|
Thomson DJ, Jamieson WR, Dumesnil JG, Busse EF, Peniston CM, Métras J, Abel JG, Sullivan JA, Parrott JC. Medtronic mosaic porcine bioprosthesis satisfactory early clinical performance. Ann Thorac Surg 1998; 66:S122-5. [PMID: 9930431 DOI: 10.1016/s0003-4975(98)01128-x] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND The Medtronic (Minneapolis, MN) Mosaic porcine bioprosthesis is an investigational prosthesis which incorporates zero-pressure fixation, aortic root predilation, low profile stent, and alpha oleic acid antimineralization treatment. METHODS From September 1994 to August 1996, 289 patients (mean age 70 years, range, 28 to 88 years) had 227 (78.5%) aortic valve replacements and 62 (21.5%) mitral valve replacements. Concomitant procedures were performed in 61.2% (139) of aortic valve replacements and 54.8% (34) of mitral valve replacements. Of the aortic valve replacement group 70 (30.8%) were in the 61 to 70 age group and 134 (59.0%) were 71 years or older. Of the mitral valve replacements, 23 (37.1%) were 61 to 70 years and 30 (48.4%) 71 years or older. RESULTS The early mortality, overall, was 4.2% (12 of 289); for aortic valve replacement it was 4.0% (9) and for mitral valve replacement it was 4.8% (3). The late mortality for aortic valve replacement was 2.6% per patient-year (3 events, 1.3% of total) and for mitral valve replacement it was 3.3% per patient-year (one event, 1.6% of total). The reoperative rate for aortic valve replacement was 3.0% per patient-year (4), while there were no mitral valve replacement reoperations. The freedom from major thromboembolism was 97.3%+/-1.6% for aortic valve replacement and 94.7%+/-3.0% for mitral valve replacement at 1 to 1.5 years. The freedom from reoperation was 96.7%+/-1.7% for aortic valve replacement; there was no reoperation for mitral valve replacement. There were no cases of structural valve deterioration. In the aortic position the mean systolic gradient was low, approximately 11 mm Hg, across all sizes (range 8 to 12 mm Hg at 3 months and 10 to 13 mm Hg at 12 months). In the mitral position the mean diastolic gradient was approximately 5 mm Hg (range, 2 to 6 mm Hg) for all sizes 25 to 31 mm at the early and 1 year follow-up echocardiographic assessment. CONCLUSIONS The early clinical performance and in vivo hemodynamics are encouraging.
Collapse
Affiliation(s)
- D J Thomson
- Canadian Clinical Investigators of Saskatoon, Saskatchewan, Canada
| | | | | | | | | | | | | | | | | |
Collapse
|
8
|
d'Udekem Y, Pasquet A, El Khoury GA, Nouwen J, Vanoverschelde JL, Robert A, Dion RA. Early calcific stenosis of the aortic sorin pericarbon valve implanted in the elderly. Ann Thorac Surg 1998; 66:S139-42. [PMID: 9930435 DOI: 10.1016/s0003-4975(98)01031-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND We reviewed our experience with the Sorin Pericarbon (Sorin, Saluggia, Italy) valve implanted in the aortic position. METHODS From January 1990 to January 1996, 143 consecutive patients had a Pericarbon valve implanted in the aortic position. The mean age was 75+/-5 years. Seventy-eight patients (55%) were in New York Heart Association (NYHA) class III or IV. Sixty patients (42%) had one or more concomitant procedures (51 coronary artery bypass grafting [CABG], 7 carotid endarterectomies, 9 others). RESULTS The hospital mortality rate was 12% (17 of 143 patients). The follow-up was 100% complete and the median time was 42 months (range, 2 to 79 months). There were 36 late deaths, 20 being cardiac-related: 5 non-valve-related, 11 valve-related, and 4 sudden unexpected deaths. The 5-year actuarial survival was 57%+/-5%. There were 6 early valve failures related to a calcific stenosis at a median time of 36 months (range, 5 to 66 months). Three patients had to undergo another operation and one of these patients died. One patient died the day before the planned reoperation and 2 patients are followed with a symptomatic aortic stenosis but refuse reoperation. Freedom from structural deterioration was 93%+/-3% at 4 years. Echocardiographic examination was obtained in 73 patients at a median time of 42 months (range, 4 to 79 months). Four additional asymptomatic patients were found to have calcifications of their prosthesis. The 5-year freedom from thromboembolic events and from endocarditis were, respectively, 87%+/-5% and 92%+/-3%. CONCLUSION The surprisingly high rate of early failure due to calcific stenosis and of thromboembolic events of the Pericarbon valve implanted in the aortic position in the elderly made us discontinue its use in our institution.
Collapse
Affiliation(s)
- Y d'Udekem
- Cliniques Universitaires Saint-Luc, Brussels, Belgium.
| | | | | | | | | | | | | |
Collapse
|
9
|
He GW, Grunkemeier GL, Starr A. Aortic valve replacement in elderly patients: influence of concomitant coronary grafting on late survival. Ann Thorac Surg 1996; 61:1746-51. [PMID: 8651778 DOI: 10.1016/0003-4975(96)00143-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Aortic valve replacement (AVR) has been an accepted therapy for elderly patients (> 70 years) with aortic valve disease. This study was designed to investigate the determinants of survival after the implantation of aortic valve prostheses, with emphasis on the effect of concomitant coronary artery bypass grafting on survival. METHODS From November 1964 to July 1994,963 elderly patients underwent isolated AVR. Long-term survival was investigated in 877 patients (70 to 94 years) who survived operation, with 92% follow-up completeness (mean +/- standard deviation, 4.5 +/- 3.9 years; maximum, 20.1 years; total, 3,920.2 patient-years), by univariate and multivariate analyses. RESULTS Actuarial survival was 38.1% +/- 2.8% at 10 years, 17.8% +/- 3.0% at 15 years, and 9.0% +/- 3.1% at 20 years. Eight variables (age, sex, body surface area [less or greater than 1.7 m2], period of operation, type of prosthesis, size of prosthesis, re-replacement, and concomitant coronary artery bypass grafting) were investigated with regard to long-term survival by the Kaplan-Meier method. Age, sex, and body surface area were significant. Multivariate analysis revealed that older age (p = 0.0005) and male sex (p = 0.0001) were independent variables that determined long-term survival. CONCLUSIONS Elderly patients may have satisfactory long-term results after AVR. Age and sex are independent determinants. Other factors (such as concomitant coronary artery bypass grafting and type of prosthesis) did not independently influence long-term survival. Coronary revascularization in elderly patients with coronary disease undergoing AVR may lead to a long-term survival similar to that in patients without coronary disease undergoing AVR.
Collapse
Affiliation(s)
- G W He
- Department of Surgery, University of Hong Kong, Grantham Hospital, Hong Kong
| | | | | |
Collapse
|