Barker AF, Iwata-Morgan I, Oveson L, Roussel R. Pharmacokinetic study of alpha1-antitrypsin infusion in alpha1-antitrypsin deficiency.
Chest 1997;
112:607-13. [PMID:
9315791 DOI:
10.1378/chest.112.3.607]
[Citation(s) in RCA: 53] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVES
To ascertain how long 120 mg/kg alpha1-antitrypsin concentrate (alpha1-AT-C), administered I.V. every 2 weeks, can maintain alpha1-antitrypsin (alpha1-AT) serum levels above 70 to 80 mg/dL. Secondary objectives were to summarize the nature, severity, and relationship of a plasma-derived alpha1-AT-C infusion to any side effects.
METHODS
This was an open-label uncontrolled pharmacokinetic study. Alpha1-AT-C was administered I.V. every 2 weeks for 10 infusions in 23 patients with PIZ alpha1-AT deficiency. Serum alpha1-AT levels and neutralizing elastase activity were measured preinfusion, postinfusion, and at nadir. During two infusion periods, daily serum alpha1-AT and neutralizing elastase activities were measured on the seventh to 14th days. Five patients received BAL assays for alpha1-AT and neutralizing elastase activity. Adverse events were recorded in a patient diary and by a nurse at each infusion visit.
RESULTS
The 120-mg/kg dose of alpha1-AT-C could not maintain nadir serum protective levels above 70 or 80 mg/dL for the entire 14-day dosing interval in most patients. None of the patients had alpha1-AT levels above 80 mg/dL for all 14 days. The serum alpha1-AT and neutralizing elastase levels correlated suggesting functional activity. The BAL alpha1-AT and neutralizing elastase activities were low and did not correlate with serum levels.
CONCLUSION
Alpha1-AT-C at 120 mg/kg administered every 2 weeks did not maintain nadir serum alpha1-AT levels above 70 to 80 mg/dL for a 14-day dosing interval. Higher doses every 2 weeks or decreased interval between infusions may be required.
Collapse