• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4606711)   Today's Articles (2299)   Subscriber (49373)
For: Panagiotopoulos E, Fortis AP, Millis Z, Lambiris E, Kostopoulos V, Vellios L. Pattern of screw loosening in fractures fixed with conventional and functional plates. Injury 1994;25:515-7. [PMID: 7960068 DOI: 10.1016/0020-1383(94)90092-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Number Cited by Other Article(s)
1
Mohandes Y, Tahani M, Rouhi G. Osteosynthesis of diaphyseal tibia fracture with locking compression plates: A numerical investigation using Taguchi and ANOVA. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021;37:e3528. [PMID: 34486240 DOI: 10.1002/cnm.3528] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Accepted: 08/29/2021] [Indexed: 06/13/2023]
2
Phen HM, Wise B, Thompson D, Nascone J, Boissonneault A, Maceroli M. Fully threaded sacroiliac lag screws have higher load to failure when compared to partially threaded screws: A biomechanical study. J Clin Orthop Trauma 2020;11:1151-1157. [PMID: 33192022 PMCID: PMC7656480 DOI: 10.1016/j.jcot.2020.10.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 10/15/2020] [Accepted: 10/15/2020] [Indexed: 11/30/2022]  Open
3
Feng X, Lin G, Fang CX, Lu WW, Chen B, Leung FKL. Bone resorption triggered by high radial stress: The mechanism of screw loosening in plate fixation of long bone fractures. J Orthop Res 2019;37:1498-1507. [PMID: 30908687 DOI: 10.1002/jor.24286] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2018] [Accepted: 03/08/2019] [Indexed: 02/04/2023]
4
Sezek S, Aksakal B, Gürger M, Malkoc M, Say Y. Biomechanical comparison of straight and helical compression plates for fixation of transverse and oblique bone fractures: Modeling and experiments. Biomed Mater Eng 2016;27:197-209. [PMID: 27567775 DOI: 10.3233/bme-161576] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
5
Are allogenic or xenogenic screws and plates a reasonable alternative to alloplastic material for osteosynthesis—A histomorphological analysis in a dynamic system. J Biomech 2010;43:3112-7. [DOI: 10.1016/j.jbiomech.2010.08.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2010] [Revised: 07/27/2010] [Accepted: 08/08/2010] [Indexed: 10/19/2022]
6
HAASE K, ROUHI G. A Discussion on Plating Factors that Affect Stress Shielding Using Finite Element Analysis. ACTA ACUST UNITED AC 2010. [DOI: 10.1299/jbse.5.129] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
7
Krishna KR, Sridhar I, Ghista DN. Analysis of the helical plate for bone fracture fixation. Injury 2008;39:1421-36. [PMID: 18823624 DOI: 10.1016/j.injury.2008.04.013] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2008] [Revised: 04/07/2008] [Accepted: 04/17/2008] [Indexed: 02/02/2023]
8
Gefen A. Computational simulations of stress shielding and bone resorption around existing and computer-designed orthopaedic screws. Med Biol Eng Comput 2002;40:311-22. [PMID: 12195978 DOI: 10.1007/bf02344213] [Citation(s) in RCA: 76] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
9
Graham AK, Hess DP, Stephens HM. Screw loosening in an in vitro mid fibular osteotomy model under dynamic loading conditions. Foot Ankle Int 2000;21:849-51. [PMID: 11128016 DOI: 10.1177/107110070002101009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA