Rabel K, Zimmermann L, Nold J, Kohal RJ, Spies BC, Adolfsson E, Lüchtenborg J, Altmann B. Identification of a surface texture parameter panel characterizing surface micromorphologies of differently processed oral implant surfaces. Dent Mater 2025:S0109-5641(25)00296-9. [PMID: 40164522 DOI: 10.1016/j.dental.2025.03.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2024] [Revised: 03/22/2025] [Accepted: 03/22/2025] [Indexed: 04/02/2025]
Abstract
OBJECTIVES Inconsistent characterization of oral implant microtopography makes it difficult to compare and evaluate available data on microtopography and the biological response to topographical characteristics. The aim of this investigation was therefore to identify a surface texture parameter panel that enables a discriminative characterization of differently processed oral implant surfaces. MATERIALS AND METHODS Surface micromorphologies of titanium- and ceramic-based biomaterials processed by machining or by machining and subsequent post-processing, including blasting, etching, anodization or porous sintering, were analyzed by scanning electron microscopy and white light interferometry. It was then analyzed which of the parameters Sa, Sq, Sz, Ssk, Sku, Str, Sal, Spd, Spc, Sdq and Sdr best characterized morphological surface features and hence should be reported as minimum parameter panel for implant surface characterization. RESULTS SEM demonstrated that each surface processing resulted in a specific and biomaterial-dependent micromorphology. The data revealed that the micromorphology of machined surfaces was best characterized by Sa, Sdr, Str and Ssk, and that for post-processed surfaces Spd and Spc were additionally required. Based on these data, Sa, Sdr, Str, Ssk, Spd and Spc were identified as minimum parameter panel for discriminative description of the investigated implant microtopographies. SIGNIFICANCE The present investigation identified Sa, Sdr, Str, Ssk, Spd and Spc as minimum parameter panel for discriminative oral implant surface characterization. The widespread use of such a panel combined with biological data will help to identify cell-relevant implant surface structures, thus enabling the design of oral implants with predefined biological response.
Collapse
Affiliation(s)
- Kerstin Rabel
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center ‑ University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, Freiburg 79106, Germany.
| | - Lars Zimmermann
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center ‑ University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, Freiburg 79106, Germany
| | - Julian Nold
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center ‑ University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, Freiburg 79106, Germany
| | - Ralf J Kohal
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center ‑ University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, Freiburg 79106, Germany
| | - Benedikt C Spies
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center ‑ University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, Freiburg 79106, Germany
| | - Erik Adolfsson
- Division Materials and Production, RISE Research Institutes of Sweden, Argongatan 30, Mölndal 43153, Sweden
| | - Jörg Lüchtenborg
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center ‑ University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, Freiburg 79106, Germany
| | - Brigitte Altmann
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center ‑ University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, Freiburg 79106, Germany; G.E.R.N Research Center for Tissue Replacement, Regeneration & Neogenesis, Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center ‑ University of Freiburg, Faculty of Medicine, University of Freiburg, Engesserstr. 4, Freiburg 79108, Germany
| |
Collapse
|
2
|
Ha JH, Choe JH, Seo JW, Kim JS, Kim DM. Experimental Analysis of Robotic Cortical Bone Specimen Drilling Performance: Effect of Cryogen. J Biomech Eng 2024; 146:111007. [PMID: 39037619 DOI: 10.1115/1.4066022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Accepted: 07/18/2024] [Indexed: 07/23/2024]
Abstract
In orthopedic surgery, precise bone screw insertion is crucial for stabilizing fractures, necessitating a preliminary cortical bone drilling procedure. However, this process can induce temperatures exceeding 70 °C due to the low thermal conductivity of cortical bone, potentially leading to thermal osteonecrosis. Furthermore, significant cutting forces and torque pose risks of tool breakage and bone damage, underlining the need for high precision and optimal processing parameters. Traditionally, drilling relies on the surgeon's experience and often results in imprecise outcomes due to inconsistent feed rates. Therefore, this study proposes the use of a 6-axis robot for controlled drilling, offering precise control over angular velocities and consistent feed rates. Additionally, explore the use of cryogenic liquid nitrogen (LN2) as a novel cooling method compared to conventional saline solutions, examining its efficacy under various cutting conditions. The results demonstrate that LN2 cooling conditions lead to a reduction in thrust and torque under specific processing conditions, and facilitate smoother chip evacuation. Additionally, LN2 significantly lowers the peak temperature around the drilling site, thus minimizing the risk of thermal osteonecrosis. Consequently, the use of a 6-axis robot provides consistent feed rates, and LN2 cooling achieves optimal processing conditions, enabling a more controlled and effective drilling process.
Collapse
Affiliation(s)
- Ju-Hyung Ha
- Dongnam Division, Korea Institute of Industrial Technology, 25, Yeonkkot-ro 165beon-gil, Jeongchon-myeon, Jinju-si, Gyeongsangnam-do 52845, South Korea
- Korea Institute of Industrial Technology
| | - Joon-Hyeok Choe
- Department of Precision Mechanical Engineering, Kyungpook National University, Gyeongsangdae-ro, 2559, Sangju-si, Gyeongsangbukd-do 37224, South Korea
- Kyungpook National University
| | - Jae-Woo Seo
- Department of Mechanical Convergence Engineering, Gyeongsang National University, Charyong-ro, 48beon-gil, Changwon-si, Gyeongsangnam-do 52828, South Korea
- Gyeongsang National University
| | - Ji-Soo Kim
- Department of Precision Mechanical Engineering, Kyungpook National University, Gyeongsangdae-ro, 2559, Sangju-si, Gyeongsangbukd-do 37224, South Korea
- Kyungpook National University
| | - Dong Min Kim
- Dongnam Division, Korea Institute of Industrial Technology, 25, Yeonkkot-ro 165beon-gil, Jeongchon-myeon, Jinju-si, Gyeongsangnam-do 52845, South Korea
| |
Collapse
|
3
|
Rajpurohit K, Dodwad V, Kharat A, Belludi S, Pharne P, Marium S. Influence of surface texture on osteogenic differentiation of dental pulp stem cells: An in vitro study. J Indian Soc Periodontol 2024; 28:478-483. [PMID: 40018713 PMCID: PMC11864341 DOI: 10.4103/jisp.jisp_307_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 12/19/2024] [Accepted: 12/20/2024] [Indexed: 03/01/2025] Open
Abstract
Background In comparison with perfectly machined surface implants, surface topographic modifications like roughness accelerate the osteogenesis of dental pulpal stem cells (DPSC). This greatly enhances bone-implant contact and osteogenic potential of the stem cells. Hence, the aim of the current study was to evaluate and compare the differentiation and proliferation potential of stem cells obtained from dental pulp on sand-blasted and acid etched implant discs surfaces. Materials and Methods Stem cells from dental pulp were extracted from the premolar region of oral cavity. Titanium discs that measured one centimeter in diameter and three millimetres in thickness were used as investigation surfaces. Titanium surface disc were acid etched and sandblasted. Investigation had three group: acid etched (Group A), sandblasted (Group B), and standard control group, i.e., cells treated with osteogenic induction media only (Group C). In Group C, mesenchymal stem cells (MSCs) were treated with osteogenic induction medium without any titanium disc and these cells were used as standard controls. To identify which modified implant surface had greater potential for proliferation, 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay was performed using the explant culture. MTT assay assessed the viability of the cells as a function of its redox potential. This was followed by recognition of the stem cells for CD90, CD73, and CD 105 markers using flow cytometry with RUNX2 antibody on days 7 and 21 of incubation. The isolated cells were stained using 1% alizarin red stain to identify the number of stem cells per square centimeter area under the light microscope. Results The osteogenic differentiation of both the materials was compared with standard control (MSCs treated with osteogenic differentiation media only). The osteoblastic cells on the acid-etched and sand-blasted implant surface disc had an almost identical capacity for proliferation till the MTT assay but according to the results of the alizarin red staining there was a slightly higher proliferation potential on acid etched surfaces compared to the sand blasted surfaces. Therefore, acid etched surfaces showed higher potential of osteogenic differentiation of DPSCs compared with sand-blasted surfaces. Conclusion In comparison with perfectly machined surface implants, topographic surface modifications such as roughness can accelerate the osteogenesis of DPSC in vitro.
Collapse
Affiliation(s)
- Komal Rajpurohit
- Department of Periodontology, Bharati Vidyapeeth (Deemed to be University) Dental college and Hospital, Pimpri, Pune, Maharashtra, India
| | - Vidya Dodwad
- Department of Periodontology, Bharati Vidyapeeth (Deemed to be University) Dental college and Hospital, Pimpri, Pune, Maharashtra, India
| | - Avinash Kharat
- Regenerative Medicine Laboratory, Dr. D.Y. Patil Dental College and Hospital, Dr. D.Y. Patil Vidyapeeth, Pimpri, Pune, Maharashtra, India
| | - Spoorthi Belludi
- Department of Periodontology, K.L.E Society of Dental Sciences, Rajiv Gandhi University of Health Sciences, Bengaluru, Karnataka, India
| | - Pooja Pharne
- Department of Periodontology, Bharati Vidyapeeth (Deemed to be University) Dental college and Hospital, Pimpri, Pune, Maharashtra, India
| | - Sarah Marium
- Department of Periodontology, Bharati Vidyapeeth (Deemed to be University) Dental college and Hospital, Pimpri, Pune, Maharashtra, India
| |
Collapse
|
4
|
Grandfield K, Binkley DM, Ay B, Liu ZM, Wang X, Davies JE. Nanoscale implant anchorage aided by cement line deposition into titanium dioxide nanotubes. J Biomed Mater Res A 2023; 111:1866-1874. [PMID: 37358344 DOI: 10.1002/jbm.a.37585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 05/25/2023] [Accepted: 06/09/2023] [Indexed: 06/27/2023]
Abstract
The success of titanium dental implants relies on osseointegration, the load-bearing connection between bone tissue and the device that, in contact osteogenesis, comprises the deposition of bony cement line matrix onto the implant surface. Titanium dioxide nanotubes (NTs) are considered a promising surface for improved osseointegration, yet the mechanisms of cement line integration with such features remains elusive. Herein, we illustrate cement line deposition into NTs on the surface of titanium implants with two underlaying microstructures: a machined surface or a blasted/acid etched surface placed in the tibiae of Wistar rats. After retrieval, scanning electron microscopy of tissue reflected from the implant surface indicated minimal incursion of the cement line matrix into the NTs. To investigate this further, focused ion beam was utilized to prepare cross-sectional samples that could be characterized using scanning transmission electron microscopy. The cement line matrix covered NTs regardless of underlying microstructure, which was further confirmed by elemental analysis. In some instances, cement line infiltration into the NTs was noted, which reveals a mechanism of nanoscale anchorage. This study is the first to demonstrate cement line deposition into titanium NTs, suggesting nano-anchorage as a mechanism for the success of the NT modified surfaces in vivo.
Collapse
Affiliation(s)
- Kathryn Grandfield
- Department of Materials Science and Engineering, McMaster University, Hamilton, Ontario, Canada
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada
| | - Dakota Marie Binkley
- Department of Materials Science and Engineering, McMaster University, Hamilton, Ontario, Canada
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada
| | - Birol Ay
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Zhen Mei Liu
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Xiaoyue Wang
- Department of Materials Science and Engineering, McMaster University, Hamilton, Ontario, Canada
| | - John E Davies
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
- Faculty of Dentistry, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
5
|
Chauhan P, Srivastava A, Bhati P, Chaturvedi M, Patil V, Kunnoth S, Kumari N, Arya V, Pandya M, Agarwal M, Bhardwaj S, Faraz F, Chauhan S, Verma M, Koul V, Bhatnagar N. Enhanced osseointegration of drug eluting nanotubular dental implants: An in vitro and in vivo study. Bioact Mater 2023; 28:432-447. [PMID: 37426894 PMCID: PMC10329101 DOI: 10.1016/j.bioactmat.2023.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 05/16/2023] [Accepted: 06/05/2023] [Indexed: 07/11/2023] Open
Abstract
Faster and predictable osseointegration is crucial for the success of dental implants, especially in patients with compromised local or systemic conditions. Despite various surface modifications on the commercially available Titanium (Ti) dental implants, the bioactivity of Ti is still low. Thus, to achieve both biological and therapeutic activity on titanium surfaces, surface modification techniques such as titanium nanotubes have been studied as nanotube surfaces can hold therapeutic drugs and molecules. The main aim of the present research work is to study the early osseointegration around the novel Simvastatin drug eluting nanotubular dental implant. In the present research, the titanium nanotubes were fabricated on the screw-shaped dental implant surface and the Simvastatin drug was loaded into the nanotubes using the ultrasonication dip method. In vitro and In vivo studies were carried out on the modified dental implants. In vitro cell culture study reported enhanced osteogenic activity on the drug-loaded nanotube surface implants. The invivo animal studies were evaluated by micro-CT, histopathology, and reverse torque removal analysis methods. The test results showed faster osseointegration with the strong interface on the Simvastatin drug-loaded implant surface at 4 weeks of healing as compared to the control implants.
Collapse
Affiliation(s)
- Pankaj Chauhan
- Homi Bhabha Cancer Hospital and Research Centre, Vizag, Andhra Pradesh, India
- Centre for Biomedical Engineering, Indian Institute of Technology Delhi, India
| | - Alok Srivastava
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, India
| | - Pooja Bhati
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, India
- Mechanical & Automation Engineering, Indira Gandhi Delhi Technical University for Women, New Delhi, India
| | - Manish Chaturvedi
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, India
- Rajasthan Technical University, Kota Rajasthan, India
| | - Vinay Patil
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, India
| | - Sriram Kunnoth
- Applied Mechanics, Indian Institute of Technology Delhi, India
| | - Nisha Kumari
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, India
| | - Vedpal Arya
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, India
- National University of Singapore, Singapore
| | - Madhur Pandya
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, India
| | - Mohit Agarwal
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, India
| | - Smiti Bhardwaj
- Department of Periodontics, Maulana Azad Institute of Dental Sciences, New Delhi, India
| | - Farrukh Faraz
- Department of Periodontics, Maulana Azad Institute of Dental Sciences, New Delhi, India
| | - Sanjay Chauhan
- Rajasthan Dental College and Hospital, Jaipur, Rajasthan, India
| | - Mahesh Verma
- Department of Prosthodontics, Maulana Azad Institute of Dental Sciences, New Delhi, India
| | - Veena Koul
- Centre for Biomedical Engineering, Indian Institute of Technology Delhi, India
| | - Naresh Bhatnagar
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, India
| |
Collapse
|
6
|
Babadjanov F, Specht U, Lukasczyk T, Mayer B. Heat Accumulation-Induced Surface Structures at High Degrees of Laser Pulse Overlap on Ti6Al4V Surfaces by Femtosecond Laser Texturing. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2498. [PMID: 36984383 PMCID: PMC10059092 DOI: 10.3390/ma16062498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 03/15/2023] [Accepted: 03/17/2023] [Indexed: 06/18/2023]
Abstract
In this work, femtosecond laser pulses at high repetition rates were used to fabricate unique microstructures on the surface of Ti6Al4V. We investigated the influence of pulse overlap and laser repetition rates on structure formation. Laser texturing with a high degree of overlap resulted in melting of the material, leading to the formation of specific microstructures that can be used as cavities for drug delivery. The reason for melt formation is attributed to local heat accumulation at high repetition rates. Such structures can be fabricated on materials with low thermal conductivity, which prevent heat dissipation into the bulk of the material. The heat accumulation effect has also been demonstrated on steel, which also has low thermal conductivity.
Collapse
Affiliation(s)
- Farkhod Babadjanov
- Fraunhofer Institute for Manufacturing Technology and Advanced Materials IFAM, Wiener Str. 12, 28359 Bremen, Germany
| | - Uwe Specht
- Fraunhofer Institute for Manufacturing Technology and Advanced Materials IFAM, Wiener Str. 12, 28359 Bremen, Germany
| | - Thomas Lukasczyk
- Fraunhofer Institute for Manufacturing Technology and Advanced Materials IFAM, Wiener Str. 12, 28359 Bremen, Germany
| | - Bernd Mayer
- Fraunhofer Institute for Manufacturing Technology and Advanced Materials IFAM, Wiener Str. 12, 28359 Bremen, Germany
- Faculty of Production Engineering, University of Bremen, 28359 Bremen, Germany
| |
Collapse
|
7
|
Abstract
Surface characteristics are an important factor for long-term clinical success of dental implants. Alterations of implant surface characteristics accelerate or improve osseointegration by interacting with the physiology of bone healing. Dental implant surfaces have been traditionally modified at the microlevel. Recently, researchers have actively investigated nano-modifications in dental implants. This review explores implant surface modifications that enhance biological response at the interface between a bone and the implant.
Collapse
Affiliation(s)
- In-Sung Luke Yeo
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101 Daehak-Ro, Jongro-Gu, Seoul 03080, Korea.
| |
Collapse
|
8
|
Innovative Surface Modification Procedures to Achieve Micro/Nano-Graded Ti-Based Biomedical Alloys and Implants. COATINGS 2021. [DOI: 10.3390/coatings11060647] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Due to the growing aging population of the world, and as a result of the increasing need for dental implants and prostheses, the use of titanium and its alloys as implant materials has spread rapidly. Although titanium and its alloys are considered the best metallic materials for biomedical applications, the need for innovative technologies is necessary due to the sensitivity of medical applications and to eliminate any potentially harmful reactions, enhancing the implant-to-bone integration and preventing infection. In this regard, the implant’s surface as the substrate for any reaction is of crucial importance, and it is accurately addressed in this review paper. For constructing this review paper, an internet search was performed on the web of science with these keywords: surface modification techniques, titanium implant, biomedical applications, surface functionalization, etc. Numerous recent papers about titanium and its alloys were selected and reviewed, except for the section on forthcoming modern implants, in which extended research was performed. This review paper aimed to briefly introduce the necessary surface characteristics for biomedical applications and the numerous surface treatment techniques. Specific emphasis was given to micro/nano-structured topographies, biocompatibility, osteogenesis, and bactericidal effects. Additionally, gradient, multi-scale, and hierarchical surfaces with multifunctional properties were discussed. Finally, special attention was paid to modern implants and forthcoming surface modification strategies such as four-dimensional printing, metamaterials, and metasurfaces. This review paper, including traditional and novel surface modification strategies, will pave the way toward designing the next generation of more efficient implants.
Collapse
|
9
|
Liu Y, Rui Z, Cheng W, Song L, Xu Y, Li R, Zhang X. Characterization and evaluation of a femtosecond laser-induced osseointegration and an anti-inflammatory structure generated on a titanium alloy. Regen Biomater 2021; 8:rbab006. [PMID: 33738120 PMCID: PMC7955712 DOI: 10.1093/rb/rbab006] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 01/05/2021] [Accepted: 01/14/2021] [Indexed: 02/07/2023] Open
Abstract
Cell–material interactions during early osseointegration of the bone–implant interface are critical and involve crosstalk between osteoblasts and osteoclasts. The surface properties of titanium implants also play a critical role in cell–material interactions. In this study, femtosecond laser treatment and sandblasting were used to alter the surface morphology, roughness and wettability of a titanium alloy. Osteoblasts and osteoclasts were then cultured on the resulting titanium alloy disks. Four disk groups were tested: a polished titanium alloy (pTi) control; a hydrophilic micro-dislocation titanium alloy (sandblasted Ti (STi)); a hydrophobic nano-mastoid Ti alloy (femtosecond laser-treated Ti (FTi)); and a hydrophilic hierarchical hybrid micro-/nanostructured Ti alloy [femtosecond laser-treated and sandblasted Ti (FSTi)]. The titanium surface treated by the femtosecond laser and sandblasting showed higher biomineralization activity and lower cytotoxicity in simulated body fluid and lactate dehydrogenase assays. Compared to the control surface, the multifunctional titanium surface induced a better cellular response in terms of proliferation, differentiation, mineralization and collagen secretion. Further investigation of macrophage polarization revealed that increased anti-inflammatory factor secretion and decreased proinflammatory factor secretion occurred in the early response of macrophages. Based on the above results, the synergistic effect of the surface properties produced an excellent cellular response at the bone–implant interface, which was mainly reflected by the promotion of early ossteointegration and macrophage polarization.
Collapse
Affiliation(s)
- Yang Liu
- Department of Orthopedics, Tianjin Medical University General Hospital, Tianjin 300052, China.,Institute of Medical Service Support, Institute of Systems Engineering, Academy of Military Sciences, Tianjin, China
| | - Zhongying Rui
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Tianjin 300052, China
| | - Wei Cheng
- Department of Orthopedics, Tianjin Medical University General Hospital, Tianjin 300052, China.,Institute of Medical Service Support, Institute of Systems Engineering, Academy of Military Sciences, Tianjin, China
| | - Licheng Song
- Department of Orthopedics, Tianjin Medical University General Hospital, Tianjin 300052, China.,Institute of Medical Service Support, Institute of Systems Engineering, Academy of Military Sciences, Tianjin, China
| | - Yunqiang Xu
- Department of Orthopedics, Tianjin Medical University General Hospital, Tianjin 300052, China
| | - Ruixin Li
- Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction, Tianjin Stomatological Hospital, The Affiliated Stomatological Hospital of Nankai University, Tianjin 300041, China
| | - Xizheng Zhang
- Institute of Medical Service Support, Institute of Systems Engineering, Academy of Military Sciences, Tianjin, China
| |
Collapse
|
10
|
Surface modification techniques of titanium and titanium alloys for biomedical dental applications: A review. ACTA ACUST UNITED AC 2021. [DOI: 10.1016/j.matpr.2020.06.163] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
11
|
Hultin K, Eriksson A, Backe C, Johansson U, Bougas K. A Pilot Study with Randomised Controlled Design Comparing TiZr Alloy Dental Implants to Ti Implants. EJOURNAL OF ORAL MAXILLOFACIAL RESEARCH 2020; 11:e3. [PMID: 33598111 PMCID: PMC7875101 DOI: 10.5037/jomr.2020.11403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Accepted: 12/28/2020] [Indexed: 11/16/2022]
Abstract
Objectives Evidence on the clinical performance of recently introduced dental implants in titanium-zirconium alloy is sparse. The aim of the present pilot study with randomized controlled design is to compare changes in supporting structures around dental titanium-zirconium alloy implants to commercially pure titanium implants. Material and Methods The present material includes consecutive patients referred to a specialist clinic in Sweden. Two patient groups treated with dental implants in two different materials - titanium (Ti) and titanium-zirconium (TiZr) - were defined after block randomisation for smoking. In total, 40 implants installed in 21 patients were available for one-year follow-up. Marginal bone level, soft tissue height and width of keratinised mucosa were registered at baseline and at one-year follow-up. Results At implant level, the test group (TiZr) yielded significant marginal bone loss (P < 0.001) after one year. Additionally, marginal bone loss after one year was significantly higher for TiZr implants (P < 0.001) as compared to traditional Ti implants. Soft tissue dimensions were stable throughout the evaluation time for both implant materials. Conclusions One-year results indicate more pronounced initial marginal bone loss for dental implants in titanium-zirconium alloy as compared to implants made of commercially pure titanium.
Collapse
Affiliation(s)
- Kristina Hultin
- Department of Prosthodontics, Södra Älvsborg Hospital, BoråsSweden
| | - Annelie Eriksson
- Department of Oral and Maxillofacial Surgery, Södra Älvsborg Hospital, BoråsSweden
| | - Christina Backe
- Department of Oral and Maxillofacial Surgery, Södra Älvsborg Hospital, BoråsSweden
| | - Ulf Johansson
- Department of Oral and Maxillofacial Surgery, Södra Älvsborg Hospital, BoråsSweden
| | - Kostas Bougas
- Department of Periodontology, Södra Älvsborg Hospital, BoråsSweden
| |
Collapse
|
12
|
Schweitzer L, Cunha A, Pereira T, Mika K, Botelho do Rego AM, Ferraria AM, Kieburg H, Geissler S, Uhlmann E, Schoon J. Preclinical In Vitro Assessment of Submicron-Scale Laser Surface Texturing on Ti6Al4V. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E5342. [PMID: 33255765 PMCID: PMC7728373 DOI: 10.3390/ma13235342] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 11/20/2020] [Accepted: 11/23/2020] [Indexed: 12/14/2022]
Abstract
Loosening of orthodontic and orthopedic implants is a critical and common clinical problem. To minimize the numbers of revision surgeries due to peri-implant inflammation or insufficient osseointegration, developments of new implant manufacturing strategies are indicated. Ultrafast laser surface texturing is a promising contact-free technology to modify the physicochemical properties of surfaces toward an anti-infectious functionalization. This work aims to texture Ti6Al4V surfaces with ultraviolet (UV) and green (GR) radiation for the manufacturing of laser-induced periodic surface structures (LIPSS). The assessment of these surface modifications addresses key aspects of topography, morphology and chemical composition. Human primary mesenchymal stromal cells (hMSCs) were cultured on laser-textured and polished Ti6Al4V to characterize the surfaces in terms of their in vitro biocompatibility, cytotoxicity, and metal release. The outcomes of the in vitro experiment show the successful culture of hMSCs on textured Ti6Al4V surfaces developed within this work. Cells cultured on LIPSS surfaces were not compromised in terms of their viability if compared to polished surfaces. Yet, the hMSC culture on UV-LIPSS show significantly lower lactate dehydrogenase and titanium release into the supernatant compared to polished. Thus, the presented surface modification can be a promising approach for future applications in orthodontics and orthopedics.
Collapse
Affiliation(s)
- Luiz Schweitzer
- Fraunhofer Institute for Production Systems and Design Technology, Pascalstr. 8-9, 10587 Berlin, Germany;
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, 17475 Greifswald, Germany;
| | - Alexandre Cunha
- SENAI Innovation Institute in Manufacturing Systems and Laser Processing, Rua Arno Waldemar Döhler 308, Joinville, 89218-153 Santa Catarina, Brazil; (A.C.); (T.P.)
- Genetoo Inc., 9841 Washingtonian Blvd, Suite 200, Gaithersburg, MD 20878, USA
| | - Thiago Pereira
- SENAI Innovation Institute in Manufacturing Systems and Laser Processing, Rua Arno Waldemar Döhler 308, Joinville, 89218-153 Santa Catarina, Brazil; (A.C.); (T.P.)
| | - Kerstin Mika
- Julius Wolff Institute, Charité Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany; (K.M.); (S.G.)
- Berlin Institute of Health Center for Regenerative Therapies, Charité Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Ana Maria Botelho do Rego
- BSIRG, Departamento de Engenharia Química, iBB-Institute for Bioengineering and Biosciences, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal; (A.M.B.d.R.); (A.M.F.)
| | - Ana Maria Ferraria
- BSIRG, Departamento de Engenharia Química, iBB-Institute for Bioengineering and Biosciences, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal; (A.M.B.d.R.); (A.M.F.)
| | - Heinz Kieburg
- Laser-Mikrotechnologie Dr. Kieburg, James-Frank-Str. 15, 12489 Berlin, Germany;
| | - Sven Geissler
- Julius Wolff Institute, Charité Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany; (K.M.); (S.G.)
- Berlin Institute of Health Center for Regenerative Therapies, Charité Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Eckart Uhlmann
- Fraunhofer Institute for Production Systems and Design Technology, Pascalstr. 8-9, 10587 Berlin, Germany;
- Institute for Machine Tools and Factory Management, Technische Universität Berlin, Pascalstr. 8-9, 10587 Berlin, Germany
| | - Janosch Schoon
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, 17475 Greifswald, Germany;
- Julius Wolff Institute, Charité Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany; (K.M.); (S.G.)
| |
Collapse
|
13
|
Jiang X, Yao Y, Tang W, Han D, Zhang L, Zhao K, Wang S, Meng Y. Design of dental implants at materials level: An overview. J Biomed Mater Res A 2020; 108:1634-1661. [PMID: 32196913 DOI: 10.1002/jbm.a.36931] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Revised: 03/06/2020] [Accepted: 03/09/2020] [Indexed: 12/17/2022]
Abstract
Due to the excellent restoration of masticatory function, satisfaction on aesthetics and other superiorities, dental implants represent an effective method to resolve tooth losing and damaging. Current dental implant systems still have problems waiting to be addressed, and problems are centralized on the materials of implant bodies. This review aims to summarize major developments in the field of dental implant materials, starting with an overview on structures, procedures of dental implants and challenges of implant materials. Next, implant materials are examined in three categories, that is, metals, ceramics, and polymers, their mechanical properties, biocompatibility, and bioactivity are summarized. And as an important aspect, strategies of surface modification are also reviewed, along with some finite element analysis to guiding the research direction of implant materials. Finally, the conclusive remarks are outlined to provide an outlook on the future research directions and prospects of dental implants.
Collapse
Affiliation(s)
- Xunyuan Jiang
- The Key Laboratory of Low-Carbon Chemistry and Energy Conservation of Guangdong Province, State Key Laboratory of Optoelectronic Materials Technologies, Sun Yat-Sen University, Guangzhou, People's Republic of China
| | - Yitong Yao
- Department of Prosthodontics, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, People's Republic of China
| | - Weiming Tang
- The Key Laboratory of Low-Carbon Chemistry and Energy Conservation of Guangdong Province, State Key Laboratory of Optoelectronic Materials Technologies, Sun Yat-Sen University, Guangzhou, People's Republic of China
| | - Dongmei Han
- The Key Laboratory of Low-Carbon Chemistry and Energy Conservation of Guangdong Province, State Key Laboratory of Optoelectronic Materials Technologies, Sun Yat-Sen University, Guangzhou, People's Republic of China
| | - Li Zhang
- Analytical and Testing Center, Sichuan University, Chengdu, Sichuan, People's Republic of China
| | - Ke Zhao
- Department of Prosthodontics, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, People's Republic of China
| | - Shuanjin Wang
- The Key Laboratory of Low-Carbon Chemistry and Energy Conservation of Guangdong Province, State Key Laboratory of Optoelectronic Materials Technologies, Sun Yat-Sen University, Guangzhou, People's Republic of China
| | - Yuezhong Meng
- The Key Laboratory of Low-Carbon Chemistry and Energy Conservation of Guangdong Province, State Key Laboratory of Optoelectronic Materials Technologies, Sun Yat-Sen University, Guangzhou, People's Republic of China
| |
Collapse
|
14
|
Lukaszewska-Kuska M, Idzior-Haufa M, Dorocka-Bobkowska B. Evaluation of human osteoblast metabolic activity in modified titanium-conditioned medium. Proc Inst Mech Eng H 2020; 234:603-611. [PMID: 32167026 DOI: 10.1177/0954411920911281] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
To evaluate human osteoblast metabolic activity cultured in medium conditioned with commercially pure titanium after surface treatments with alumina or ceramic grit-blasting followed by acid etching. Commercially available, pure Grade 4 titanium disks were used and subjected to seven different surface modifications: (1) machined (MA)-used as the control group; (2) blasted with Al2O3 (Al2O3); (3) blasted with sintered ceramic (HAS); (4) blasted with non-sintered ceramics (HA); (5) blasted with Al2O3 and etched with HCl/H2SO4 (Al2O3 DE); (6) blasted with sintered ceramic and etched with HCl/H2SO4 (HAS DE), and (7) blasted with non-sintered ceramic and etched with HCl/H2SO4 (HA DE). A samples roughness evaluation test was carried out with an interference microscope, and energy-dispersive X-ray spectroscopy was performed to evaluate the presence of aluminum, phosphorus, and calcium deposited during the titanium surface treatment along with carbon contaminants acquired by the surface during processing. A culture medium conditioned with the respective samples was prepared in five dilutions, and its effect on human osteoblast cell viability was evaluated using the relative viability of cells. Human osteoblast metabolic activity was found to be the most intensive for the Al2O3 DE sample. The lowest activity was observed for the HAS DE. The material's cytocompatibility depended on both the surface roughness and its chemical composition. Etching had a dual effect on cell activity, depending on the chemical composition of the titanium surface after blasting.
Collapse
Affiliation(s)
| | - Malgorzata Idzior-Haufa
- Department of Gerodontology and Oral Pathology, Poznan University of Medical Sciences, Poznan, Poland
| | - Barbara Dorocka-Bobkowska
- Department of Gerodontology and Oral Pathology, Poznan University of Medical Sciences, Poznan, Poland
| |
Collapse
|
15
|
Effect of Laser Pulse Overlap and Scanning Line Overlap on Femtosecond Laser-Structured Ti6Al4V Surfaces. MATERIALS 2020; 13:ma13040969. [PMID: 32098103 PMCID: PMC7079643 DOI: 10.3390/ma13040969] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Revised: 02/14/2020] [Accepted: 02/20/2020] [Indexed: 12/23/2022]
Abstract
Surface structuring is a key factor for the tailoring of proper cell attachment and the improvement of the bone-implant interface anchorage. Femtosecond laser machining is especially suited to the structuring of implants due to the possibility of creating surfaces with a wide variety of nano- and microstructures. To achieve a desired surface topography, different laser structuring parameters can be adjusted. The scanning strategy, or rather the laser pulse overlap and scanning line overlap, affect the surface topography in an essential way, which is demonstrated in this study. Ti6Al4V samples were structured using a 300 fs laser source with a wavelength of 1030 nm. Laser pulse overlap and scanning line overlap were varied between 40% and 90% over a wide range of fluences (F from 0.49 to 12.28 J/cm²), respectively. Four different main types of surface structures were obtained depending on the applied laser parameters: femtosecond laser-induced periodic surface structures (FLIPSS), micrometric ripples (MR), micro-craters, and pillared microstructures. It could also be demonstrated that the exceedance of the strong ablation threshold of Ti6Al4V strongly depends on the scanning strategy. The formation of microstructures can be achieved at lower levels of laser pulse overlap compared to the corresponding value of scanning line overlap due to higher heat accumulation in the irradiated area during laser machining.
Collapse
|
16
|
Sasikumar Y, Indira K, Rajendran N. Surface Modification Methods for Titanium and Its Alloys and Their Corrosion Behavior in Biological Environment: A Review. ACTA ACUST UNITED AC 2019. [DOI: 10.1007/s40735-019-0229-5] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
17
|
Yoruç ABH, Keleşoğlu E, Yıldız HE. In vitro bioactivity of laser surface-treated Ti6Al4V alloy. Lasers Med Sci 2019; 34:1567-1573. [PMID: 30798388 DOI: 10.1007/s10103-019-02746-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Accepted: 02/07/2019] [Indexed: 10/27/2022]
Abstract
The effects of lasing parameters on the precipitation of hydroxyapatite (HA) on the commercial Ti6Al4V alloy in simulated body fluid (SBF) were investigated. Ti6Al4V plates were polished and ultrasonically cleaned in acetone and ethyl alcohol, respectively. The specimen surfaces were treated with Er:YAG laser using super short pulse (SSP, 50 μs) and very short pulse (VSP, 100 μs) modes. Surface roughness was measured before and after laser treatment. The specimens were immersed in simulated body fluid (SBF) for 1, 3, and 7 days and, then the amount of Ca and P precipitation on specimens was determined using SEM/EDS analysis. An average roughness varying between 0.19 and 0.81 μm in surface roughness was detected in all laser-treated specimens depending on the lasing parameters. The highest surface roughness and Ca precipitation were found in VSP group (20 Hz and 5 W). Laser treatment of specimen surfaces has dramatically increased the HA precipitation due to the increasing surface roughness. It is also concluded that the immersion time was effective on the HA precipitation as well.
Collapse
Affiliation(s)
- Afife Binnaz Hazar Yoruç
- Department of Metallurgical and Materials Engineering, Yildiz Technical University, Istanbul, Turkey.
| | - Ergün Keleşoğlu
- Department of Metallurgical and Materials Engineering, Yildiz Technical University, Istanbul, Turkey
| | - Harika Ekşioğlu Yıldız
- Department of Metallurgical and Materials Engineering, Yildiz Technical University, Istanbul, Turkey
| |
Collapse
|
18
|
Calvo-Guirado JL, Maté-Sánchez de Val JE, Delgado-Ruiz RA, Fernández Domínguez M, Orlato Rossetti PH, Gehrke SA. Retracted: A new cervical implant design compared with standard design in order to increase peri-implant hard and soft tissue behavior: histomorphometric and histological study in dogs. Clin Oral Implants Res 2018; 29:815. [PMID: 27596490 DOI: 10.1111/clr.12978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/01/2016] [Indexed: 11/30/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate a new design of the cervical portion of dental implant with the objective to increase the volume of peri-implant tissues in the crestal area. MATERIALS AND METHODS Forty-eight tapered dental titanium implants with internal conical connection were implanted in healed alveolar sites of six dogs. Twenty-four conventional implants design (C1 implant) formed the control group, and 24 new implant design (V3 implant) formed the test group. The groups were randomized. Histological, histomorphometric, and implant stability quotient were performed. After 12 weeks of healing period, histomorphometric analyses of the specimens were carried out to measure the crestal bone level values and the tissue thickness in the cervical implant portion. The data were compared using statistical tests (α = 5%). RESULTS The mean of the measurements in the buccal and lingual aspects measured of crestal bone level was 0.31 ± 0.24 mm and 0.30 ± 0.19 mm in the control group, respectively, and 0.71 ± 0.28 and 0.42 ± 0.30 mm in the test group, respectively, whereas the mean of the tissue thickness was 1.63 ± 0.33 mm and 2.04 ± 0.23 mm in the control group, respectively, and 2.11 ± 0.35 mm and 2.51 ± 0.41 mm in the test group. CONCLUSIONS Within the limitations of this study, our findings suggest that more thickness of peri-implant hard and soft tissues may be expected in this new implant design. However, the control group with traditional implant design was found to have more height values of the crestal bone compared with new V3 implants.
Collapse
Affiliation(s)
- José Luis Calvo-Guirado
- International Dentistry Research Cathedra, Faculty of Medicine & Dentistry, Universidad Católica San Antonio de Murcia (UCAM), Murcia, Spain.
| | - José E Maté-Sánchez de Val
- International Dentistry Research Cathedra, Faculty of Medicine & Dentistry, Universidad Católica San Antonio de Murcia (UCAM), Murcia, Spain
| | - Rafael Arcesio Delgado-Ruiz
- Prosthodontics and Digital Technology, School of Dental Medicine, Stony Brook University, Stony Brook, NY, USA
| | | | | | - Sergio A Gehrke
- Biotecnos Research Center, Santa Maria, Brazil
- International Dentistry Research Cathedra, Universidad Católica San Antonio de Murcia (UCAM), Murcia, Spain
| |
Collapse
|
19
|
Gehrke SA, Bragança LK, Velasco-Ortega E, Calvo-Guirado JL. Evaluation of dimensional behavior of peri-implant tissues in implants immediately exposed or submerged in fresh extraction and healed sites: a histological study in dogs. Int J Implant Dent 2018; 4:5. [PMID: 29430613 PMCID: PMC6890886 DOI: 10.1186/s40729-018-0120-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Accepted: 01/10/2018] [Indexed: 11/29/2022] Open
Abstract
Background The aim of this study was to compare histologically the dimensional behavior of peri-implant tissues during osseointegration of immediately exposed or submerged implant placement in fresh extraction and healed sites. Methods Four fresh extraction and four delayed implant sites were placed in each hemimandible of five dogs at the bone crest level. In 2 implants of each side were installed a healing abutment (exposed) and two cover screw (submerged) and formed four groups: implant installed in fresh extraction submerged (group 1), implants in fresh extraction immediately exposed (group 2), implants installed in healed site submerged (group 3), and implants in healed site immediately exposed (group 4). After 12 weeks of healing period, histomorphometric analyses of the specimens were carried out to measure the crestal bone level values and the tissue thickness in the implant shoulder portion. Results The measure of crestal bone level showed some higher values for implants installed in fresh extraction sites in the buccal aspect: 1.88 ± 0.42 mm for group 1 and 2.33 ± 0.33 mm for group 2, with statistical significance among all four groups tested (P < 0.001). For peri-implant tissue thickness, a significative higher statistical difference (P < 0.001) for implants installed in healed sites (groups 3 and 4) was found. Conclusions Within the limitations of the present animal study, our findings suggest that the implants placed in fresh extraction or healed site and with regards to the moment of exposition (immediately or no) are important factors to the amount of peri-implant tissues after remodeling over a period of 12 weeks. The null hypothesis was rejected.
Collapse
Affiliation(s)
- Sergio Alexandre Gehrke
- Biotecnos Research Center, Calle Cuareim, 1483, CP: 11.100, Montevideo, Uruguay. .,University Catholica San Antonio de Murcia (UCAM), Murcia, Spain.
| | | | - Eugenio Velasco-Ortega
- General Dentistry, Seville University, Seville, Spain.,Implant Dentistry Master, Seville University, Seville, Spain
| | - José Luis Calvo-Guirado
- International Dentistry Research Cathedra, Faculty of Medicine and Dentistry, San Antonio Catholic University of Murcia (UCAM), Murcia, Spain
| |
Collapse
|
20
|
Giavaresi G, Fini M, Chiesa R, Rimondini L, Rondelli G, Borsari V, Martini L, Nicolialdini N, Guzzardella GA, Giardino R. Osseointegration of Sandblasted or Anodised Hydrothermally-Treated Titanium Implants: Mechanical, Histomorphometric and Bone Hardness Measurements. Int J Artif Organs 2018; 25:806-13. [PMID: 12296466 DOI: 10.1177/039139880202500809] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The improvement of the implant-bone interface is still an open problem in the long-term mechanical stability of cementless fixed implants. Mechanical, histomorphometric and bone hardness measurements were performed in sheep femoral cortical bone implants at 8 and 12 weeks from surgery to compare in vivo the osseointegration of titanium screws (Ø 3.5 mm × 7 mm length) with two different surface treatments: sandblasting with 70–100 μm HA followed by acid etching with HNO3 (Group A) and Ca-P anodization followed by a hydrothermal treatment (Group B). No significant differences were found for maximum push-out force and interfacial strength between groups at both experimental times. No significant difference was observed for Bone Ingrowth between groups at both experimental times, while the Affinity Index of Group B was significantly higher (7.5%, p<0.05) and lower (10.2%, p<0.05) than that of Group A at 8 and 12 weeks, respectively. Finally, a significant increase in bone microhardness measured within 200 μm from the interface and inside the thread depth of Group A was observed between the two experimental times (p<0.05). In conclusion, present findings show that osseointegration may be accelerated by adequate surface roughness and bioactive ceramic coating such as current tested treatments which enhance bone interlocking and mineralization.
Collapse
Affiliation(s)
- G Giavaresi
- Experimental Surgery Department, Research Institute Codivilla-Putti, Rizzoli Orthopaedic Institute, Bologna, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Lauria I, Höner M, Kant S, Davtalab R, Weik T, Sternberg K, Fischer H. Response of umbilical cord mesenchymal stromal cells to varying titanium topographical signals. J Biomed Mater Res A 2017; 106:180-191. [PMID: 28884523 DOI: 10.1002/jbm.a.36229] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2017] [Revised: 07/07/2017] [Accepted: 08/01/2017] [Indexed: 01/09/2023]
Abstract
A wide variety of titanium implant modifications have been developed to improve tissue- or cell-material interactions including bone bonding, implant failure, and contact osteogenesis. Osteogenesis can be stimulated by mechanobiological signals such as topography though translation of in vivo reactions to in vitro bioactivity and stem cell culture data, and vice versa, is challenging. We hypothesized that a systematic in vitro approach comparing clinically well-accepted implant surface topographical modifications could shed light on potential cell biological mechanisms provoked by submicron-, micron- or macrostructured surfaces. In this study, we investigated the response of umbilical cord derived mesenchymal stromal cells (UC-MSCs) to anodized, particle blasted, and plasma sprayed highly porous Plasmapore surfaces, which is known to promote bony ingrowth in vivo. After 21 days, UC-MSCs undergo a morphological shift from a 2D to 3D behavior on micro- or macrostructures visualized by actin-vinculin fluorescence and are able to fill the porous surfaces completely. Cell viability after 7 days was significantly decreased on the micro- and macrostructured surfaces particle blasted and Plasmapore, compared to polished controls. The analysis of osteogenic differentiation under noninduced conditions revealed a significantly elevated ALP activity on Plasmapore, indicating a beneficial effect of this macrostructured surface toward osteogenic differentiation supported by late elevated gene expression of osteopontin evaluated by qPCR. Mineralization as well as in vitro bioactivity was pronounced on anodized surfaces. Our findings point to synergistic implant modification strategies allowing early contact osteogenesis and bone ingrowth for future implant designs. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 180-191, 2018.
Collapse
Affiliation(s)
- Ines Lauria
- Department of Dental Materials and Biomaterials Research, RWTH Aachen University Hospital, Pauwelsstrasse 30, Aachen, 52074, Germany
| | - Miriam Höner
- Department of Dental Materials and Biomaterials Research, RWTH Aachen University Hospital, Pauwelsstrasse 30, Aachen, 52074, Germany
| | - Sebastian Kant
- Department of Molecular and Cellular Anatomy, RWTH Aachen University Hospital, Wendlingweg 2, 52057, Aachen, Germany
| | - Roswitha Davtalab
- Department of Dental Materials and Biomaterials Research, RWTH Aachen University Hospital, Pauwelsstrasse 30, Aachen, 52074, Germany
| | - Thomas Weik
- B. Braun Aesculap AG, Am Aesculap-Platz, 78532, Tuttlingen, Germany
| | - Katrin Sternberg
- B. Braun Aesculap AG, Am Aesculap-Platz, 78532, Tuttlingen, Germany
| | - Horst Fischer
- Department of Dental Materials and Biomaterials Research, RWTH Aachen University Hospital, Pauwelsstrasse 30, Aachen, 52074, Germany
| |
Collapse
|
22
|
Coelho PG, Zavanelli RA, Salles MB, Yeniyol S, Tovar N, Jimbo R. Enhanced Bone Bonding to Nanotextured Implant Surfaces at a Short Healing Period: A Biomechanical Tensile Testing in the Rat Femur. IMPLANT DENT 2017; 25:322-7. [PMID: 27213527 DOI: 10.1097/id.0000000000000436] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To compare the bone bonding capabilities of 2 different surface treatments at an early healing period. Titanium alloy (Ti6Al4V) custom-made rectangular plates (1.4 × 2.4 × 4 mm) were either dual acid etched (Ti6Al4V-DAE) or DAE/nanotextured blasted (Ti6Al4V-NTB). MATERIALS AND METHODS Implants were placed in the distal femurs of 10 Wistar rats and were allowed to heal for 9 days. After euthanasia, the bone immediately proximal and distal to the implant was removed to test the bone bonding force with a universal testing machine. Ultrastructure of the bone/implant interface was assessed by scanning electron microscopy. RESULTS Ti6Al4V-NTB samples exhibited significantly greater bond strength than Ti6Al4V-DAE samples. Morphologically, the Ti6Al4V-NTB surfaces presented intimate interaction with bone, whereas little interaction between the Ti6Al4V-DAE surface and bone was observed. CONCLUSION The results of this study indicated a significant increase in bone bonding for the DAE/nanotextured blasted surface, which is suggested to be the outcome of the nanotexturing.
Collapse
Affiliation(s)
- Paulo G Coelho
- *Associate Professor, Biomaterials and Biomimetics and Director for Research, Department of Periodontology and Implant Dentistry, New York University College of Dentistry, NY. †Professor, Department of Prevention and Oral Rehabilitation, Federal University of Goias School of Dentistry, Goiania, GO, Brazil. ‡Researcher, Biomaterials and Biomimetics and Director for Research, Department of Periodontology and Implant Dentistry, New York University College of Dentistry, NY. §Professor, Department of Anatomy, University of Sao Paulo, Sao Paulo, Brazil. ¶Assistant Professor, Department of Oral Implantology, Faculty of Dentistry, Istanbul University, Istanbul, Turkey. ‖Researcher, Department of Biomaterials and Biomimetics, New York University College of Dentistry, NY. #Associate Professor, Department of Prosthodontics, Faculty of Odontology, Malmö University, Malmö, Sweden
| | | | | | | | | | | |
Collapse
|
23
|
Singh S, Ramakrishna S. Biomedical applications of additive manufacturing: Present and future. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2017. [DOI: 10.1016/j.cobme.2017.05.006] [Citation(s) in RCA: 115] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
24
|
Implant Surface Modifications and Osseointegration. SPRINGER SERIES IN BIOMATERIALS SCIENCE AND ENGINEERING 2017. [DOI: 10.1007/978-3-662-53574-5_4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
25
|
Abstract
PURPOSE The aim of this study was to investigate the earlier phase of the osseointegration of a laser-treated implant surface in terms of human protein adsorption. MATERIALS AND METHODS Titanium surfaces were divided into machined (M), sandblasted (SB), and laser-treated (LT). The LT surfaces were created with an Nd diode-pumped laser in Q-switching, whereas the SB were treated with Al2O3. An x-ray photoelectron spectroscopy (XPS) analysis of titanium surface was performed. Titanium discs were used for albumin and fibronectin adsorption evaluation through fluorescence intensity. Fibronectin evaluation was also made with Western Blot analysis on experimental implants. RESULTS LT discs appeared to trigger a higher albumin and fibronectin adsorption with a regular pattern. The mean count of albumin adsorption was 0.29 and 3.8 for SB and LT, respectively (P = 0.016), whereas fibronectin values were 0.67 and 4.9 for (SB) and (LT) titanium (P = 0.02). XPS analysis showed that titanium, oxygen, carbon, and nitrogen were found on all 3 surfaces. CONCLUSION Laser-engineered porous titanium surface seems to promote, in vitro, the adsorption of albumin and fibronectin more than sandblasted (SB) or machined (M) implants.
Collapse
|
26
|
Buser D, Sennerby L, De Bruyn H. Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions. Periodontol 2000 2016; 73:7-21. [DOI: 10.1111/prd.12185] [Citation(s) in RCA: 253] [Impact Index Per Article: 28.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
27
|
Ting M, Jefferies SR, Xia W, Engqvist H, Suzuki JB. Classification and Effects of Implant Surface Modification on the Bone: Human Cell-Based In Vitro Studies. J ORAL IMPLANTOL 2016; 43:58-83. [PMID: 27897464 DOI: 10.1563/aaid-joi-d-16-00079] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Implant surfaces are continuously being improved to achieve faster osseointegration and a stronger bone to implant interface. This review will present the various implant surfaces, the parameters for implant surface characterization, and the corresponding in vitro human cell-based studies determining the strength and quality of the bone-implant contact. These in vitro cell-based studies are the basis for animal and clinical studies and are the prelude to further reviews on how these surfaces would perform when subjected to the oral environment and functional loading.
Collapse
Affiliation(s)
- Miriam Ting
- 1 Temple University Kornberg School of Dentistry, Philadelphia, Pa
| | - Steven R Jefferies
- 2 Department of Restorative Dentistry, Temple University Kornberg School of Dentistry, Philadelphia, Pa
| | - Wei Xia
- 3 Department of Engineering Science, Uppsala University, Uppsala, Sweden
| | - Håkan Engqvist
- 3 Department of Engineering Science, Uppsala University, Uppsala, Sweden
| | - Jon B Suzuki
- 4 Department of Periodontology and Oral Implantology, Temple University Kornberg School of Dentistry, Philadelphia, Pa
| |
Collapse
|
28
|
Effect of Hydrofluoric Acid Etching Time on Titanium Topography, Chemistry, Wettability, and Cell Adhesion. PLoS One 2016; 11:e0165296. [PMID: 27824875 PMCID: PMC5100918 DOI: 10.1371/journal.pone.0165296] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2016] [Accepted: 10/10/2016] [Indexed: 12/22/2022] Open
Abstract
Titanium implant surface etching has proven an effective method to enhance cell attachment. Despite the frequent use of hydrofluoric (HF) acid, many questions remain unresolved, including the optimal etching time and its effect on surface and biological properties. The objective of this study was to investigate the effect of HF acid etching time on Ti topography, surface chemistry, wettability, and cell adhesion. These data are useful to design improved acid treatment and obtain an improved cell response. The surface topography, chemistry, dynamic wetting, and cell adhesiveness of polished Ti surfaces were evaluated after treatment with HF acid solution for 0, 2; 3, 5, 7, or 10 min, revealing a time-dependent effect of HF acid on their topography, chemistry, and wetting. Roughness and wetting increased with longer etching time except at 10 min, when roughness increased but wetness decreased. Skewness became negative after etching and kurtosis tended to 3 with longer etching time. Highest cell adhesion was achieved after 5–7 min of etching time. Wetting and cell adhesion were reduced on the highly rough surfaces obtained after 10-min etching time.
Collapse
|
29
|
Gehrke SA, Ramírez-Fernandez MP, Granero Marín JM, Barbosa Salles M, Del Fabbro M, Calvo Guirado JL. A comparative evaluation between aluminium and titanium dioxide microparticles for blasting the surface titanium dental implants: an experimental study in rabbits. Clin Oral Implants Res 2016; 29:802-807. [DOI: 10.1111/clr.12973] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/14/2016] [Indexed: 11/29/2022]
Affiliation(s)
- Sergio A. Gehrke
- Biotecnos Research Center; Santa Maria Brazil
- University Catholica San Antonio de Murcia (UCAM); Murcia Spain
| | - María P. Ramírez-Fernandez
- International Dentistry Research Cathedra; Faculty of Medicine; San Antonio Catholic University of Murcia (UCAM); Murcia Spain
| | | | | | - Massimo Del Fabbro
- Research Center in Oral Health; Department of Biomedical, Surgical and Dental Sciences; Università degli Studi di Milano; IRCCS Istituto Ortopedico Galeazzi; Milano Italy
| | - José Luis Calvo Guirado
- International Dentistry Research Cathedra; Faculty of Medicine & Dentistry; San Antonio Catholic University of Murcia (UCAM); Murcia Spain
| |
Collapse
|
30
|
Comparison of surface modified zirconia implants with commercially available zirconium and titanium implants: a histological study in pigs. IMPLANT DENT 2016; 23:502-7. [PMID: 25025856 DOI: 10.1097/id.0000000000000110] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
INTRODUCTION New biomaterials and their various surface modifications should undergo in vitro and in vivo evaluation before clinical trials. The objective of our in vivo study was to evaluate the biocompatibility of newly created zirconium implant surfaces after implantation in the lower jaw of pigs and compare the osseointegration of these dental implants with commercially available zirconium and titanium implants. MATERIALS AND METHODS After a healing period of 12 weeks, a histological analysis of the soft and hard tissues and a histomorphometric analysis of the bone-implant contact (BIC) were performed. RESULTS The implant surfaces showed an intimate connection to the adjacent bone for all tested implants. The 3 newly created zirconium implant surfaces achieved a BIC of 45% on average in comparison with a BIC of 56% from the reference zirconium implants and 35% from titanium implants. Furthermore, the new zirconium implants had a better attachment to gingival and bone tissues in the range of implant necks as compared with the reference implants. CONCLUSION The results suggest that the new implants comparably osseointegrate within the healing period, and they have a good in vivo biocompatibility.
Collapse
|
31
|
Peck MT, Chrcanovic BR. Chemical and Topographic Analysis of Eight commercially Available Dental Implants. J Contemp Dent Pract 2016; 17:354-360. [PMID: 27443360 DOI: 10.5005/jp-journals-10024-1855] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
BACKGROUND Surface characterization of dental implants allows us to better understand the effects of the implant on the host biological response. In this study, we analyzed and compared these characteristics among implants commercially available in South Africa. MATERIALS AND METHODS Eight implants from different manufacturers were chosen for analysis (Touareg, ICE, (R)Evolutions, Uniti, AnyRidge, MIS, Ivory-QSI, Southern), using scanning electron microscopy (SEM), interferometry, and energy dispersive X-ray spectroscopy to study the surface chemical composition and morphology. RESULTS The results indicate that variations in manufacturer processes result in implant surfaces that are distinctly different from one another. Most implants presented a moderately rough surface with sandblasted-only implant surfaces having a lower mean value of Sa when compared with sandblasted and acid-etched surfaces. Carbon contamination was detected on all the implants and that of aluminum on five implant surfaces. Ca and P were detected on the surface of Touareg implants, indicating the manufacturer's attempt to enhance osseointegration. CONCLUSION The surface of the implants showed a range of chemical, physical properties, and surface topographies. CLINICAL SIGNIFICANCE The results indicate that implant surface treatment is not standardized. This may have clinical implications. Further clinical research is required.
Collapse
Affiliation(s)
- Mogammad T Peck
- Department of Oral Medicine and Periodontology, University of the Western Cape, Cape Town, South Africa, e-mail:
| | - Bruno R Chrcanovic
- Department of Prosthodontics, Faculty of Odontology, MalmS University, MalmS, Sweden
| |
Collapse
|
32
|
Roughness and wettability effect on histological and mechanical response of self-drilling orthodontic mini-implants. Clin Oral Investig 2016; 20:1115-20. [PMID: 26955833 DOI: 10.1007/s00784-016-1770-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2015] [Accepted: 02/29/2016] [Indexed: 10/22/2022]
Abstract
OBJECTIVES Self-drilling orthodontic mini-implants can be used as temporary devices for orthodontic treatments. Our main goal was to evaluate surface characteristics, roughness and wettability, of surface modified mini-implants to increase their stability during orthodontic treatment without inducing bone fracture and tissue destruction during unscrewing. MATERIALS AND METHODS Modified mini-implants by acid etching, grit-blasting and its combination were implanted in 20 New Zealand rabbits during 10 weeks. After that, the bone-to-implant (BIC) parameter was determined and the torque during unscrewing was measured. The surface characteristics, roughness and wettability, were also measured, onto modified Ti c.p. discs. RESULTS Acid-etched mini-implants (R a ≈ 1.7 μm, contact angle (CA) ≈ 66°) significantly improved the bone-to-implant parameter, 26 %, compared to as-machined mini-implants (R a ≈ 0.3 μm, CA ≈ 68°, BIC = 19 %) due to its roughness. Moreover, this surface treatment did not modify torque during unscrewing due to their statistically similar wettability (p > 0.05). Surface treatments with higher roughness and hydrophobicity (R a ≈ 4.5 μm, CA ≈ 74°) lead to a greater BIC and to a higher removal torque during unscrewing, causing bone fracture, compared to as-machined mini-implants. CONCLUSIONS Based on these in vivo findings, we conclude that acid-etching surface treatment can support temporary anchoring of titanium mini-implants. CLINICAL RELEVANCE This treatment represents a step forward in the direction of reducing the time prior to mini-implant loading by increasing their stability during orthodontic treatment, without inducing bone fracture and tissue destruction during unscrewing.
Collapse
|
33
|
Satué M, Monjo M, Ronold HJ, Lyngstadaas SP, Ramis JM. Titanium implants coated with UV-irradiated vitamin D precursor and vitamin E: in vivo performance and coating stability. Clin Oral Implants Res 2016; 28:424-431. [PMID: 26926140 DOI: 10.1111/clr.12815] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/24/2016] [Indexed: 12/19/2022]
Abstract
OBJECTIVES This study aimed at evaluating the biological response of titanium implants coated with UV-irradiated 7-dehydrocholesterol (7-DHC) and vitamin E (VitE) in vivo and analyzing the effects of aging on their stability and bioactivity in vitro. MATERIAL AND METHODS Titanium surfaces were coated with 7-DHC and VitE, UV-irradiated and incubated for 48 h at 23°C to allow cholecalciferol synthesis. The in vivo biological response was tested using a rabbit tibia model after 8 weeks of healing by analyzing the wound fluid and the mRNA levels of several markers at the bone-implant interface (N = 8). The stability of the coating after storage up to 12 weeks was determined using HPLC analysis, and the bioactivity of the stored modified implants was studied by an in vitro study with MC3T3-E1 cells (N = 6). RESULTS A significant increase in gene expression levels of osteocalcin was found in the bone tissue attached to implants coated with the low dose of 7-DHC and VitE, together with a higher ALP activity in the wound fluid. Implants treated with the high dose of 7-DHC and VitE showed increased tissue necrosis and inflammation. Regarding the aging effects, coated implants were stable and bioactive up to 12 weeks when stored at 4°C and avoiding oxygen, light and moisture. CONCLUSION This study demonstrates that Ti implants coated with UV-irradiated 7-DHC and VitE promote in vivo gene expression of bone formation markers and ALP activity, while they keep their osteopromotive potential in vitro and composition when stored up to 12 weeks at 4°C.
Collapse
Affiliation(s)
- María Satué
- Department of Fundamental Biology and Health Sciences, Research Institute on Health Sciences (IUNICS), University of Balearic Islands, Palma de Mallorca, Spain
| | - Marta Monjo
- Department of Fundamental Biology and Health Sciences, Research Institute on Health Sciences (IUNICS), University of Balearic Islands, Palma de Mallorca, Spain.,Instituto de Investigación Sanitaria de Palma, Palma de Mallorca, Spain
| | - Hans Jacob Ronold
- Department of Prosthetics and Oral Function, Institute for Clinical Dentistry, University of Oslo, Oslo, Norway
| | | | - Joana M Ramis
- Department of Fundamental Biology and Health Sciences, Research Institute on Health Sciences (IUNICS), University of Balearic Islands, Palma de Mallorca, Spain.,Instituto de Investigación Sanitaria de Palma, Palma de Mallorca, Spain
| |
Collapse
|
34
|
Gil FJ, Espinar E, Llamas JM, Sevilla P. Fatigue life of bioactive titanium dental implants treated by means of grit-blasting and thermo-chemical treatment. Clin Implant Dent Relat Res 2016; 16:273-81. [PMID: 24766392 DOI: 10.1111/j.1708-8208.2012.00468.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE This study focuses on the fatigue behavior of titanium dental implants as-received, with a grit-blasted surface and with a new bioactive surface treatment (2Steps). BACKGROUND The 2Step process consists of (1) an initial grit-blasting process to produce a micro-rough surface, followed by (2) a combined thermo-chemical treatment that produces a potentially bioactive surface, that is, that can form an apatitic layer when exposed to biomimetic conditions in vitro. The 2Step treatment produced micro-rough and apatitic coating implants. METHODS Residual stresses were determined by means of X-ray diffraction. The fatigue tests were carried out at 37°C on 500 dental implants, and the S-N curve was determined. The fatigue-crack nucleation for the different treatments was analyzed. RESULTS The fatigue tests show that the grit-blasting process improves the fatigue life. This is a consequence of the layer of compressive residual stresses that the treatment generates in titanium surfaces. Dental implants that had its surfaced prepared with the 2Step procedure (grit-blasting and thermo-chemical treatment) had its fatigue life decreased by 10% due to the incorporation of oxygen to the surface and the relaxation of the compressive residual stress produced by the heat treatment. CONCLUSIONS Thermo-chemical treatment is an excellent compromise between the improvement of bioactive and mechanical long-life behaviors.
Collapse
Affiliation(s)
- F Javier Gil
- Bioengineering Research Center (CREB), Department of Materials Science and Metalurgical Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain; Facultad de Odontología, Universidad de Sevilla, Sevilla, Spain
| | | | | | | |
Collapse
|
35
|
Coelho PG, Gil LF, Neiva R, Jimbo R, Tovar N, Lilin T, Bonfante EA. Microrobotized blasting improves the bone-to-textured implant response. A preclinical in vivo biomechanical study. J Mech Behav Biomed Mater 2015; 56:175-182. [PMID: 26703231 DOI: 10.1016/j.jmbbm.2015.11.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 11/06/2015] [Accepted: 11/09/2015] [Indexed: 01/25/2023]
Abstract
This study evaluated the effect of microrobotized blasting of titanium endosteal implants relative to their manually blasted counterparts. Two different implant systems were utilized presenting two different implant surfaces. Control surfaces (Manual) were fabricated by manually grit blasting the implant surfaces while experimental surfaces (Microblasted) were fabricated through a microrobotized system that provided a one pass grit blasting routine. Both surfaces were created with the same ~50µm average particle size alumina powder at ~310KPa. Surfaces were then etched with 37% HCl for 20min, washed, and packaged through standard industry procedures. The surfaces were characterized through scanning electron microscopy (SEM) and optical interferometry, and were then placed in a beagle dog radius model remaining in vivo for 3 and 6 weeks. The implant removal torque was recorded and statistical analysis evaluated implant system and surface type torque levels as a function of time in vivo. Histologic sections were qualitatively evaluated for tissue response. Electron microscopy depicted textured surfaces for both manual and microblasted surfaces. Optical interferometry showed significantly higher Sa, Sq, values for the microblasted surface and no significant difference for Sds and Sdr values between surfaces. In vivo results depicted that statistically significant gains in biomechanical fixation were obtained for both implant systems tested at 6 weeks in vivo, while only one system presented significant biomechanical gain at 3 weeks. Histologic sections showed qualitative higher amounts of new bone forming around microblasted implants relative to the manually blasted group. Microrobotized blasting resulted in higher biomechanical fixation of endosteal dental implants and should be considered as an alternative for impant surface manufacturing.
Collapse
Affiliation(s)
- Paulo G Coelho
- Department of Biomaterials and Biomimetics, New York University, 433 1st Ave., Room 844, New York, NY 10010, USA; Director for Research, Department of Periodontology and Implant Dentistry, New York University College of Dentistry, 345E 24th Street, New York, NY 10010, USA; Affiliated Faculty, Department of Engineering, New York University Abu Dhabi, PO Box 129188, Abu Dhabi, United Arab Emirates
| | - Luiz F Gil
- Department of Dentistry, Division of Oral and Maxillofacial Surgery, Universidade Federal de Santa Catarina, R. Eng. Agronômico Andrei Cristian Ferreira, s/n-Trindade, Florianópolis, SC 88040-900, Brazil
| | - Rodrigo Neiva
- Department of Periodontology, University of Florida at Gainesville, 1395 Center Dr, Gainesville, FL 32610, USA
| | - Ryo Jimbo
- Department of Prosthodontics, Malmo University, Malmo 205 06, Sweden
| | - Nick Tovar
- Department of Biomaterials and Biomimetics, New York University, 433 1st Ave., Room 844, New York, NY 10010, USA
| | - Thomas Lilin
- École Nationale Vétérinaire d׳Alfort, 7 Avenue du Général de Gaulle, 94704 Mainsons-Alfort, France
| | - Estevam A Bonfante
- Department of Prosthodontics, University of Sao Paulo - Bauru College of Dentistry, Alameda Otávio Pinheiro Brisola 9-75, Bauru, SP 17.012-901, Brazil.
| |
Collapse
|
36
|
Hicklin SP, Schneebeli E, Chappuis V, Janner SFM, Buser D, Brägger U. Early loading of titanium dental implants with an intra-operatively conditioned hydrophilic implant surface after 21 days of healing. Clin Oral Implants Res 2015; 27:875-83. [DOI: 10.1111/clr.12706] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/31/2015] [Indexed: 11/30/2022]
Affiliation(s)
- Stefan Paul Hicklin
- Department of Reconstructive Dentistry and Gerodontology; School of Dental Medicine; University of Bern; Bern Switzerland
- Division of Fixed Prosthodontics and Biomaterials; School of Dental Medicine; University of Geneva; Geneva Switzerland
| | - Esther Schneebeli
- Department of Reconstructive Dentistry and Gerodontology; School of Dental Medicine; University of Bern; Bern Switzerland
| | - Vivianne Chappuis
- Department of Oral Surgery and Stomatology; School of Dental Medicine; University of Bern; Bern Switzerland
| | | | - Daniel Buser
- Department of Oral Surgery and Stomatology; School of Dental Medicine; University of Bern; Bern Switzerland
| | - Urs Brägger
- Department of Reconstructive Dentistry and Gerodontology; School of Dental Medicine; University of Bern; Bern Switzerland
| |
Collapse
|
37
|
Zhu W, Teel G, O'Brien CM, Zhuang T, Keidar M, Zhang LG. Enhanced human bone marrow mesenchymal stem cell functions on cathodic arc plasma-treated titanium. Int J Nanomedicine 2015; 10:7385-96. [PMID: 26677327 PMCID: PMC4677661 DOI: 10.2147/ijn.s92733] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Surface modification of titanium for use in orthopedics has been explored for years; however, an ideal method of integrating titanium with native bone is still required to this day. Since human bone cells directly interact with nanostructured extracellular matrices, one of the most promising methods of improving titanium's osseointegration involves inducing bio-mimetic nanotopography to enhance cell-implant interaction. In this regard, we explored an approach to functionalize the surface of titanium by depositing a thin film of textured titanium nanoparticles via a cathodic arc discharge plasma. The aim is to improve human bone marrow mesenchymal stem cell (MSC) attachment and differentiation and to reduce deleterious effects of more complex surface modification methods. Surface functionalization was analyzed by scanning electron microscopy, atomic force microscopy, contact angle testing, and specific protein adsorption. Scanning electron microscopy and atomic force microscopy examination demonstrate the deposition of titanium nanoparticles and the surface roughness change after coating. The specific fibronectin adsorption was enhanced on the modified titanium surface that associates with the improved hydrophilicity. MSC adhesion and proliferation were significantly promoted on the nanocoated surface. More importantly, compared to bare titanium, greater production of total protein, deposition of calcium mineral, and synthesis of alkaline phosphatase were observed from MSCs on nanocoated titanium after 21 days. The method described herein presents a promising alternative method for inducing more cell favorable nanosurface for improved orthopedic applications.
Collapse
Affiliation(s)
- Wei Zhu
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC, USA
| | - George Teel
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC, USA
| | - Christopher M O'Brien
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC, USA
| | - Taisen Zhuang
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC, USA
| | - Michael Keidar
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC, USA
| | - Lijie Grace Zhang
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC, USA ; Department of Biomedical Engineering, The George Washington University, Washington, DC, USA ; Department of Medicine, The George Washington University, Washington, DC, USA
| |
Collapse
|
38
|
Buser D, Janner SFM, Wittneben JG, Brägger U, Ramseier CA, Salvi GE. 10-year survival and success rates of 511 titanium implants with a sandblasted and acid-etched surface: a retrospective study in 303 partially edentulous patients. Clin Implant Dent Relat Res 2015; 14:839-51. [PMID: 22897683 DOI: 10.1111/j.1708-8208.2012.00456.x] [Citation(s) in RCA: 384] [Impact Index Per Article: 38.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
PURPOSE This retrospective study assessed the 10-year outcomes of titanium implants with a sandblasted and acid-etched (SLA) surface in a large cohort of partially edentulous patients. MATERIALS AND METHODS Records of patients treated with SLA implants between May 1997 and January 2001 were screened. Eligible patients were contacted and invited to undergo a clinical and radiologic examination. Each implant was classified according to strict success criteria. RESULTS Three hundred three patients with 511 SLA implants were available for the examination. The mean age of the patients at implant surgery was 48 years. Over the 10-year period, no implant fracture was noted, whereas six implants (1.2%) were lost. Two implants (0.4%) showed signs of suppuration at the 10-year examination, whereas seven implants had a history of peri-implantitis (1.4%) during the 10-year period, but presented with healthy peri-implant soft tissues at examination. The remaining 496 implants fulfilled the success criteria. The mean Plaque Index was 0.65 (±0.64), the mean Sulcus Bleeding Index 1.32 (±0.57), the mean Probing Depth 3.27 mm (±1.06), and the mean distance from the implant shoulder to the mucosal margin value -0.42 mm (±1.27). The radiologic mean distance from the implant shoulder to the first bone-to-implant contact was 3.32 mm (±0.73). CONCLUSION The present retrospective analysis resulted in a 10-year implant survival rate of 98.8% and a success rate of 97.0%. In addition, the prevalence of peri-implantitis in this large cohort of orally healthy patients was low with 1.8% during the 10-year period.
Collapse
Affiliation(s)
- Daniel Buser
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | | | | | | | | | | |
Collapse
|
39
|
Mahapatro A. Bio-functional nano-coatings on metallic biomaterials. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 55:227-51. [DOI: 10.1016/j.msec.2015.05.018] [Citation(s) in RCA: 81] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2014] [Revised: 03/20/2015] [Accepted: 05/07/2015] [Indexed: 11/28/2022]
|
40
|
Halldin A, Ander M, Jacobsson M, Hansson S. Simulation of the mechanical interlocking capacity of a rough bone implant surface during healing. Biomed Eng Online 2015; 14:45. [PMID: 25994839 PMCID: PMC4440247 DOI: 10.1186/s12938-015-0038-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Accepted: 04/16/2015] [Indexed: 11/16/2022] Open
Abstract
Background When an implant is inserted in the bone the healing process starts to osseointegrate the implant by creating new bone that interlocks with the implant. Biomechanical interlocking capacity is commonly evaluated in in vivo experiments. It would be beneficial to find a numerical method to evaluate the interlocking capacity of different surface structures with bone. In the present study, the theoretical interlocking capacity of three different surfaces after different healing times was evaluated by the means of explicit finite element analysis. Methods The surface topographies of the three surfaces were measured with interferometry and were used to construct a 3D bone-implant model. The implant was subjected to a displacement until failure of the bone-to-implant interface and the maximum force represents the interlocking capacity. Results The simulated ratios (test/control) seem to agree with the in vivo ratios of Halldin et al. for longer healing times. However the absolute removal torque values are underestimated and do not reach the biomechanical performance found in the study by Halldin et al. which might be a result of unknown mechanical properties of the interface. Conclusion Finite element analysis is a promising method that might be used prior to an in vivo study to compare the load bearing capacity of the bone-to-implant interface of two surface topographies at longer healing times.
Collapse
Affiliation(s)
- Anders Halldin
- Department of Prosthodontics, Faculty of Odontology, Malmö University, 205 06, Malmö, Sweden. .,DENTSPLY Implants, Box 14, 43121, Mölndal, Sweden.
| | - Mats Ander
- Department of Applied Mechanics, Chalmers University of Technology, 41296, Gothenburg, Sweden.
| | - Magnus Jacobsson
- Department of Prosthodontics, Faculty of Odontology, Malmö University, 205 06, Malmö, Sweden.
| | - Stig Hansson
- DENTSPLY Implants, Box 14, 43121, Mölndal, Sweden.
| |
Collapse
|
41
|
Lee SY, Kim SJ, An HW, Kim HS, Ha DG, Ryo KH, Park KB. The effect of the thread depth on the mechanical properties of the dental implant. J Adv Prosthodont 2015; 7:115-21. [PMID: 25932309 PMCID: PMC4414941 DOI: 10.4047/jap.2015.7.2.115] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2014] [Revised: 02/02/2015] [Accepted: 02/24/2015] [Indexed: 11/13/2022] Open
Abstract
PURPOSE This study aimed to evaluate the effect of implant thread depth on primary stability in low density bone. MATERIALS AND METHODS The insertion torque was measured by inserting Ti implants with different thread depths into solid rigid polyurethane blocks (Sawbones) with three different bone densities (0.16 g/cm3, 0.24 g/cm3, and 0.32 g/cm3). The insertion torque value was evaluated with a surgical engine. The static compressive strength was measured with a universal testing machine (UTM) and the Ti implants were aligned at 30° against the loading direction of the UTM. After the static compressive strength test, the Ti implants were analyzed with a Measurescope. RESULTS The Ti implants with deeper thread depth showed statistically higher mean insertion torque values (P<.001). Groups A and group B had similar maximum static compressive strengths, as did groups C and D (P>.05). After the static compressive strength, the thread shape of the Ti implants with deeper thread depth did not show any breakage but did show deformation of the implant body and abutment. CONCLUSION The implants with deeper thread depth had higher mean insertion torque values but not lower compressive strength. The deep threads had a mechanical stability. Implants with deeper thread depth may increase the primary stability in areas of poor quality bone without decreasing mechanical strength.
Collapse
Affiliation(s)
- Sun-Young Lee
- Institute of Science & Technology, Megagen Implant, Gyeongsan, Republic of Korea
| | - Sung-Jun Kim
- Institute of Science & Technology, Megagen Implant, Gyeongsan, Republic of Korea
| | - Hyun-Wook An
- Institute of Science & Technology, Megagen Implant, Gyeongsan, Republic of Korea. ; Department of Periodontology, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| | - Hyun-Seung Kim
- Institute of Science & Technology, Megagen Implant, Gyeongsan, Republic of Korea
| | - Dong-Guk Ha
- Institute of Science & Technology, Megagen Implant, Gyeongsan, Republic of Korea
| | - Kyung-Ho Ryo
- Institute of Science & Technology, Megagen Implant, Gyeongsan, Republic of Korea
| | | |
Collapse
|
42
|
Surface Characterization and In Vivo Evaluation of Dual Acid-Etched and Grit-Blasted/Acid-Etched Implants in Sheep. IMPLANT DENT 2015; 24:256-62. [DOI: 10.1097/id.0000000000000248] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
43
|
Biomimetic approaches in bone tissue engineering: Integrating biological and physicomechanical strategies. Adv Drug Deliv Rev 2015; 84:1-29. [PMID: 25236302 DOI: 10.1016/j.addr.2014.09.005] [Citation(s) in RCA: 294] [Impact Index Per Article: 29.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2014] [Revised: 09/01/2014] [Accepted: 09/05/2014] [Indexed: 02/06/2023]
Abstract
The development of responsive biomaterials capable of demonstrating modulated function in response to dynamic physiological and mechanical changes in vivo remains an important challenge in bone tissue engineering. To achieve long-term repair and good clinical outcomes, biologically responsive approaches that focus on repair and reconstitution of tissue structure and function through drug release, receptor recognition, environmental responsiveness and tuned biodegradability are required. Traditional orthopedic materials lack biomimicry, and mismatches in tissue morphology, or chemical and mechanical properties ultimately accelerate device failure. Multiple stimuli have been proposed as principal contributors or mediators of cell activity and bone tissue formation, including physical (substrate topography, stiffness, shear stress and electrical forces) and biochemical factors (growth factors, genes or proteins). However, optimal solutions to bone regeneration remain elusive. This review will focus on biological and physicomechanical considerations currently being explored in bone tissue engineering.
Collapse
|
44
|
Implant surface characteristics and their effect on osseointegration. Br Dent J 2015; 218:E9. [DOI: 10.1038/sj.bdj.2015.171] [Citation(s) in RCA: 105] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/12/2015] [Indexed: 11/08/2022]
|
45
|
Electrochemical behavior and effect of heat treatment on morphology, crystalline structure of self-organized TiO2 nanotube arrays on Ti-6Al-7Nb for biomedical applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 50:394-401. [PMID: 25746285 DOI: 10.1016/j.msec.2015.02.013] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2014] [Revised: 12/20/2014] [Accepted: 02/09/2015] [Indexed: 11/20/2022]
Abstract
In the present work, we investigate the formation of self-organized titanium oxide nanotube layers by anodic oxidation on titanium alloy Ti-6Al-7Nb in electrolyte solution containing sulfuric acid and hydrofluoric acid. The anodized surface was characterized by micro-Raman, X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM) and energy-dispersive X-ray spectroscopy (EDS). The corrosion behavior of the treated and untreated samples was investigated through electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization studies in simulated body fluid (Hanks' solution). The investigations show that the native oxide on the sample is replaced by self-assembled nanoarray by anodization. FESEM of samples annealed at 450 to 800 °C show tubular morphology whereas those annealed at 850 °C show collapse of nanotubes. Electrochemical impedance data of the substrate and 10 V anodized samples were fitted with a two-time constant equivalent circuit and that of anodized samples (20, 30 V) with a three-time constant equivalent circuit.
Collapse
|
46
|
Dunne CF, Twomey B, Kelly C, Simpson JC, Stanton KT. Hydroxyapatite and fluorapatite coatings on dental screws: effects of blast coating process and biological response. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2015; 26:5347. [PMID: 25578701 DOI: 10.1007/s10856-014-5347-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2014] [Accepted: 08/03/2014] [Indexed: 06/04/2023]
Abstract
This paper describes the deposition of hydroxyapatite (HA) and fluorapatite (FA) onto titanium dental screws using a novel ambient temperature coating technique named CoBlast. The process utilises a coating medium and a blast medium sprayed simultaneously at the substrate surface. The blast medium was a sintered apatite (sHA) and two particles sizes (<106 and <180 µm) were used to assess their influence on the coating process. The influence of the coating process on the coating composition, coating adhesion, screw morphology and screw microstructure was examined. XRD analysis revealed the coating crystallinity was the same as the original HA and FA feedstock powders. Examining the screw's morphology, the threads of the CoBlasted screws exhibited rounding compared to the unmodified screw. This is due to the abrasive nature of the CoBlast process. The degree of rounding was more significant for the screws blasted with the 180 µm sHA than the 106 µm sHA. The blast media particle size significantly influences the surface roughness of both the substrate and coating and the microstructure of the substrate. The screws did not exhibit any loss of coating after insertion into a model bone material, indicating that the coating was strongly adhered to the substrate. There was no statistically significant difference in cell attachment and cell morphology on the unmodified substrates compared to the coated substrates. In conclusion, the CoBlast process can be used to deposit HA and FA onto complex geometries such as dental screws. The choice of blast medium particle size influences the screws morphology. The coating process does not negatively impact on the cell attachment and morphology in vitro.
Collapse
Affiliation(s)
- Conor F Dunne
- UCD School of Mechanical and Materials Engineering, University College Dublin, Belfield, Dublin 4, Ireland
| | | | | | | | | |
Collapse
|
47
|
Osseointegration: hierarchical designing encompassing the macrometer, micrometer, and nanometer length scales. Dent Mater 2014; 31:37-52. [PMID: 25467952 DOI: 10.1016/j.dental.2014.10.007] [Citation(s) in RCA: 120] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2014] [Revised: 09/14/2014] [Accepted: 10/31/2014] [Indexed: 01/14/2023]
Abstract
OBJECTIVE Osseointegration has been a proven concept in implant dentistry and orthopedics for decades. Substantial efforts for engineering implants for reduced treatment time frames have focused on micrometer and most recently on nanometer length scale alterations with negligible attention devoted to the effect of both macrometer design alterations and surgical instrumentation on osseointegration. This manuscript revisits osseointegration addressing the individual and combined role of alterations on the macrometer, micrometer, and nanometer length scales on the basis of cell culture, preclinical in vivo studies, and clinical evidence. METHODS A critical appraisal of the literature was performed regarding the impact of dental implant designing on osseointegration. Results from studies with different methodological approaches and the commonly observed inconsistencies are discussed. RESULTS It is a consensus that implant surface topographical and chemical alterations can hasten osseointegration. However, the tailored combination between multiple length scale design parameters that provides maximal host response is yet to be determined. SIGNIFICANCE In spite of the overabundant literature on osseointegration, a proportional inconsistency in findings hitherto encountered warrants a call for appropriate multivariable study designing to ensure that adequate data collection will enable osseointegration maximization and/or optimization, which will possibly lead to the engineering of endosteal implant designs that can be immediately placed/loaded regardless of patient dependent conditions.
Collapse
|
48
|
Ballo AM, Cekic-Nagas I, Ergun G, Lassila L, Palmquist A, Borchardt P, Lausmaa J, Thomsen P, Vallittu PK, Närhi TO. Osseointegration of fiber-reinforced composite implants: histological and ultrastructural observations. Dent Mater 2014; 30:e384-95. [PMID: 25182369 DOI: 10.1016/j.dental.2014.08.361] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2013] [Revised: 06/19/2014] [Accepted: 08/08/2014] [Indexed: 11/29/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate the bone tissue response to fiber-reinforced composite (FRC) in comparison with titanium (Ti) implants after 12 weeks of implantation in cancellous bone using histomorphometric and ultrastructural analysis. MATERIALS AND METHODS Thirty grit-blasted cylindrical FRC implants with BisGMA-TEGDMA polymer matrix were fabricated and divided into three groups: (1) 60s light-cured FRC (FRC-L group), (2) 24h polymerized FRC (FRC group), and (3) bioactive glass FRC (FRC-BAG group). Titanium implants were used as a control group. The surface analyses were performed with scanning electron microscopy and 3D SEM. The bone-implant contact (BIC) and bone area (BA) were determined using histomorphometry and SEM. Transmission electron microscopy (TEM) was performed on Focused Ion Beam prepared samples of the intact bone-implant interface. RESULTS The FRC, FRC-BAG and Ti implants were integrated into host bone. In contrast, FRC-L implants had a consistent fibrous capsule around the circumference of the entire implant separating the implant from direct bone contact. The highest values of BIC were obtained with FRC-BAG (58±11%) and Ti implants (54±13%), followed by FRC implants (48±10%), but no significant differences in BIC or BA were observed (p=0.07, p=0.06, respectively). TEM images showed a direct contact between nanocrystalline hydroxyapatite of bone and both FRC and FRC-BAG surfaces. CONCLUSION Fiber-reinforced composite implants are capable of establishing a close bone contact comparable with the osseointegration of titanium implants having similar surface roughness.
Collapse
Affiliation(s)
- A M Ballo
- Department of Oral Health Sciences, Faculty of Dentistry, University of British Columbia, Vancouver, BC, Canada; Dental Implant and Osseointegration Research Chair, College of Dentistry at King Saud University, Riyadh, Saudi Arabia.
| | - I Cekic-Nagas
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara, Turkey
| | - G Ergun
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara, Turkey
| | - L Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre - TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - A Palmquist
- Department of Biomaterials, Institute for Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden; BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden
| | - P Borchardt
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden; SP Technical Research Institute Sweden, Borås, Sweden
| | - J Lausmaa
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden; SP Technical Research Institute Sweden, Borås, Sweden
| | - P Thomsen
- Department of Biomaterials, Institute for Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden; BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden
| | - P K Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre - TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - T O Närhi
- Department of Prosthetic Dentistry, Institute of Dentistry, University of Turku, Turku, Finland; Clinic of Oral Diseases, Turku University Central Hospital, Turku, Finland
| |
Collapse
|
49
|
Affiliation(s)
- Ole Reigstad
- Hand- and Microsurgery section Orthopaedic department OUS-Rikshospitalet Postboks 4950 Nydalen 0424 Oslo Norway
| |
Collapse
|
50
|
Boquete-Castro A, Gómez-Moreno G, Aguilar-Salvatierra A, Delgado-Ruiz RA, Romanos GE, Calvo-Guirado JL. Influence of the implant design on osseointegration and crestal bone resorption of immediate implants: a histomorphometric study in dogs. Clin Oral Implants Res 2014; 26:876-881. [PMID: 24665897 DOI: 10.1111/clr.12381] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/22/2014] [Indexed: 11/28/2022]
Abstract
PURPOSE The aim of this study was to evaluate bone-to-implant contact after immediate implant placement at different levels in relation to crestal bone in American foxhound dogs. MATERIALS AND METHODS The mandibular second, third, and fourth premolars of six American foxhound dogs were extracted bilaterally. Randomly, three immediate implants were placed in the hemimandible of each dog at the bone crest (control group) or 2 mm subcrestally (test group). Three dogs were allowed an 8-week healing period; the other three were left a 12-week healing period. After healing periods, histomorphometric analyses of the specimens were carried out to measure BIC values and bone remodeling. RESULTS All implants healed uneventfully and were available for histological analysis. The total BIC mean values were 44.52% (± 8.67) and 39.50% (± 9.25) at 8 and 12 weeks, respectively, for the control group, and 47.33% (± 5.23) and 53.85% (± 4.21) at 8 and 12 weeks after healing for the test group, respectively. There was observed less bone resorption in the group of implants placed subcrestally. CONCLUSION Our findings suggest that less resorption may be expected when implants are inserted 2 mm subcrestally. Moreover, higher BIC values in the group of subcrestal implants were found.
Collapse
|