• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4612468)   Today's Articles (73)   Subscriber (49385)
For: Diaz GV, el-Issa LH, Arnold MA, Miller RF. Feasibility of continuous glutamate monitoring in perfused retinal tissue with a potentiometric biosensing probe. J Neurosci Methods 1988;23:63-9. [PMID: 2894485 DOI: 10.1016/0165-0270(88)90023-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Number Cited by Other Article(s)
1
Arnold MA, Meyerhoff ME. Recent Advances in the Development and Analytical Applications of Biosensing Probes. ACTA ACUST UNITED AC 2006. [DOI: 10.1080/00078988808048811] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
2
Tucci S, Rada P, Sepúlveda MJ, Hernandez L. Glutamate measured by 6-s resolution brain microdialysis: capillary electrophoretic and laser-induced fluorescence detection application. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 1997;694:343-9. [PMID: 9252048 DOI: 10.1016/s0378-4347(96)00488-4] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
3
Hernandez L, Escalona J, Verdeguer P, Guzman NA. In Vivo Monitoring of Brain Glutamate by Microdialysis Coupled to Capillary Electrophoresis and Laser Induced Fluorescence Detection. ACTA ACUST UNITED AC 1993. [DOI: 10.1080/10826079308019921] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
4
Botrè C, Botrè F, Galli M, Lorenti G, Mazzei F, Porcelli F. Determination of glutamic acid decarboxylase activity and inhibition by an H2O2-sensing glutamic acid oxidase biosensor. Anal Biochem 1992;201:227-32. [PMID: 1352947 DOI: 10.1016/0003-2697(92)90332-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
5
Comparison of two fibre-optic l-glutamate biosensors based on the detection of oxygen or carbon dioxide, and their application in combination with flow-injection analysis to the determination of glutamate. Anal Chim Acta 1991. [DOI: 10.1016/s0003-2670(00)84651-6] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
6
Luong J, Mulchandani A, Male K. Development of a substrate recycle amplification system for l-glutamic acid assay. Enzyme Microb Technol 1991. [DOI: 10.1016/0141-0229(91)90165-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
7
Koryta J. Theory and applications of ion-selective electrodes. Part 8. Anal Chim Acta 1990. [DOI: 10.1016/s0003-2670(00)83457-1] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA