Galanti LM, Dell'Omo J, Wanet B, Guarin JL, Jamart J, Garrino MG, Masson PL, Cambiaso CL. Particle counting assay for anti-toxoplasma IgG antibodies. Comparison with four automated commercial enzyme-linked immunoassays.
J Immunol Methods 1997;
207:195-201. [PMID:
9368646 DOI:
10.1016/s0022-1759(97)00120-8]
[Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
An assay for anti-toxoplasma IgG antibodies based on agglutination of latex particles was set up and compared with commercial immunoassays. The reaction was measured by instrumental counting of particles remaining unagglutinated. The running time was 45 min. This test (PaC) was compared using 243 serum samples with four automated commercial immunoassays: the Enzymum test Toxo IgG (ES300, Boehringer), the Vidas Toxo IgG (Biomérieux), the IMX Toxo IgG (Abbott), the Magia Toxoplasma gondii IgG (Merck). The mean values (+/- SD) obtained by IMX (25 IU +/- 68) and ES300 (45 IU +/- 142) were significantly lower than the values obtained by Vidas (73 IU +/- 237, p < 10(-4) and p = 0.006, respectively), by Magia (80 IU +/- 300, p < 10(-4) and p = 0.0005) and by PaC (70 IU +/- 260, p < 10(-4) and p = 0.0126). The correlations between PaC and Toxo IgG Boehringer, Biomérieux, Abbott, Merck were r = 0.97, r = 0.98, r = 0.94, r = 0.98, respectively. The correlation coefficients between the enzyme-immunoassays ranged from 0.96 to 0.99. All positive samples by PaC were found to be positive by enzyme-immunoassays except for eight sera which were doubtful positives by the Enzymum test ToxoIgG from Boehringer. No negative sample by PaC was found positive by any of the enzyme-immunoassays. In PaC, when two latex preparations coated with different antigen were compared, the correlation was rather weak (r = 0.93) suggesting that the selection of the antigen can be critical. In conclusion, the four automated commercial immunoassays now available gave similar results. However, the discrepancies observed in this study underlined the importance of clinical and biological follow-up of the patients and the necessity to confirm the result. The introduction of a new technique such as PaC, which is now available for a large variety of assays in Clinical Chemistry and Microbiology, is justified by its intrinsic advantage of homogeneity. Therefore, automation is easy as well as the control of possible interference.
Collapse