• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4623447)   Today's Articles (8)   Subscriber (49408)
For: Panjabi MM, Yamamoto I, Oxland TR, Crisco JJ, Freedman D. Biomechanical stability of five pedicle screw fixation systems in a human lumbar spine instability model. Clin Biomech (Bristol, Avon) 1991;6:197-205. [PMID: 23915564 DOI: 10.1016/0268-0033(91)90047-t] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/1990] [Accepted: 03/07/1991] [Indexed: 02/07/2023]
Number Cited by Other Article(s)
1
Alkalay RN, Sharpe D, Bader DL. A biomechanical analysis of an instrumented spinal fixator under torsional loads. J Biomech 2005;38:865-76. [PMID: 15713308 DOI: 10.1016/j.jbiomech.2004.04.029] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/27/2004] [Indexed: 11/23/2022]
2
Ferrara LA, Secor JL, Jin BH, Wakefield A, Inceoglu S, Benzel EC. A biomechanical comparison of facet screw fixation and pedicle screw fixation: effects of short-term and long-term repetitive cycling. Spine (Phila Pa 1976) 2003;28:1226-34. [PMID: 12811265 DOI: 10.1097/01.brs.0000065485.46539.17] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
3
Oda T, Panjabi MM. Pedicle screw adjustments affect stability of thoracolumbar burst fracture. Spine (Phila Pa 1976) 2001;26:2328-33. [PMID: 11679817 DOI: 10.1097/00007632-200111010-00008] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
4
Panjabi MM, Kato Y, Hoffman H, Cholewicki J, Krag M. A study of stiffness protocol as exemplified by testing of a burst fracture model in sagittal plane. Spine (Phila Pa 1976) 2000;25:2748-54. [PMID: 11064519 DOI: 10.1097/00007632-200011010-00006] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
5
Vahldiek MJ, Panjabi MM. Stability potential of spinal instrumentations in tumor vertebral body replacement surgery. Spine (Phila Pa 1976) 1998;23:543-50. [PMID: 9530785 DOI: 10.1097/00007632-199803010-00006] [Citation(s) in RCA: 65] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
6
Wilke HJ, Krischak ST, Wenger KH, Claes LE. Load-displacement properties of the thoracolumbar calf spine: experimental results and comparison to known human data. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 1997;6:129-37. [PMID: 9209882 PMCID: PMC3454592 DOI: 10.1007/bf01358746] [Citation(s) in RCA: 69] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/1996] [Revised: 08/31/1996] [Accepted: 09/16/1996] [Indexed: 02/04/2023]
7
Berlemann U, Cripton P, Nolte LP, Lippuner K, Schläpfer F. New means in spinal pedicle hook fixation. A biomechanical evaluation. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 1995;4:114-22. [PMID: 7600149 DOI: 10.1007/bf00278923] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
8
Wilke HJ, Claes L, Schmitt H, Wolf S. A universal spine tester for in vitro experiments with muscle force simulation. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 1994;3:91-7. [PMID: 7874556 DOI: 10.1007/bf02221446] [Citation(s) in RCA: 209] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
PrevPage 1 of 1 1Next