Narendra R, Reddy NS, Reddy SD, Purna CRS, Shekar MC, Balasubramanyam S. A comparative evaluation of impact strength of conventionally heat cured and high impact heat cured polymethyl methacrylate denture base resins: an in vitro study.
J Contemp Dent Pract 2013;
14:1115-1121. [PMID:
24858761 DOI:
10.5005/jp-journals-10024-1461]
[Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
UNLABELLED
The denture bases made by using polymethyl methacrylates of Acrylic resin family have excellent physical properties, simple to process and easy to reline, rebase and repair. One of the inherent disadvantages of this material is the liability to break during function. The strength assessment of acrylic resins have been made generally by transverse defection tests.
AIM
To evaluate the impact strength valves of certain brands of commercially available denture base resins and suggest their suitability.
MATERIALS AND METHODS
The denture bases we made using polymethyl methacrylates of acrylic resin family because they have excellent physical properties, simple to process and easy to reline and rebase. Six commercial brands of polymethyl meth- acrylate, namely Stellon (DPI-India), Acralyn-H (Asian Acrylate, India), Trevalon (Dentsply-England), Lucitone 199 (Dentsply/ York division), Acralyn-H (Super Unbreakable), Trevalon HI (Dentsply, Detray division, England) were tested by breaking them using Analog Pendulum (ASTM D 256).
RESULTS
From the entire study the maximum impact strength was reported for Acralyn-H super unbreakable (Asian Acrylates, India) 62.19 joules.
CONCLUSION
All the analysis led to conclusion that there is basic change in material composition within and among the different groups of denture base resins.
CLINICAL IMPLICATIONS
The complete dentures made using denture base resins with high impact strength valves (e.g. Acralyn-H super unbreakable) will be more durable and can be used by the patient for considerable period of time, i.e. beyond 4 to 5 years.