1
|
Blood Volume Required for Detection of Low Levels and Ultralow Levels of Organisms Responsible for Neonatal Bacteremia by Use of Bactec Peds Plus/F, Plus Aerobic/F Medium, and the BD Bactec FX System: an In Vitro Study. J Clin Microbiol 2015; 53:3609-13. [PMID: 26292299 DOI: 10.1128/jcm.01706-15] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2015] [Accepted: 08/11/2015] [Indexed: 12/25/2022] Open
Abstract
We used an in vitro technique to investigate blood volumes required to detect bacteremia and fungemia with low concentrations of an organism. At 1 to 10 CFU/ml, Escherichia coli, Staphylococcus epidermidis, Staphylococcus aureus, Listeria monocytogenes, Candida albicans, and Candida parapsilosis isolates were detected in volumes as low as 0.5 ml. Detection of Streptococcus agalactiae and detection of bacteremia at <1 CFU/ml were unreliable.
Collapse
|
2
|
Schwarz NG, Sarpong N, Hünger F, Marks F, Acquah SE, Agyekum A, Nkrumah B, Loag W, Hagen RM, Evans JA, Dekker D, Fobil JN, Meyer CG, May J, Adu-Sarkodie Y. Systemic bacteraemia in children presenting with clinical pneumonia and the impact of non-typhoid salmonella (NTS). BMC Infect Dis 2010; 10:319. [PMID: 21050455 PMCID: PMC2991321 DOI: 10.1186/1471-2334-10-319] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2010] [Accepted: 11/04/2010] [Indexed: 11/25/2022] Open
Abstract
Background The diagnosis and antimicrobial treatment of pneumonia in African children in the absence of diagnostic means such as x-ray facilities or microbiological laboratories relies primarily on clinical symptoms presented by the patients. In order to assess the spectrum of bacterial pathogens, blood cultures were performed in children fulfilling the clinical criteria of pneumonia. Methods In total, 1032 blood cultures were taken from children between 2 months and 5 years of age who were admitted to a rural hospital in Ghana between September 2007 and July 2009. Pneumonia was diagnosed clinically and according to WHO criteria classified as "non-severe pneumonia" and "severe pneumonia" ("severe pneumonia" includes the WHO categories "severe pneumonia" and "very severe pneumonia"). Results The proportion of bacteriaemia with non-typhoid salmonella (NTS) was similar in children with pneumonia (16/173, 9.2%) compared to children hospitalized for other reasons (112/859, 13%). NTS were the predominant organisms isolated from children with clinical pneumonia and significantly more frequent than Streptococcus pneumoniae (8/173, 4.6%). Nine percent (9/101) of children presenting with severe pneumonia and 10% (7/72) of children with non-severe pneumonia were infected with NTS. Nineteen out of 123 NTS isolates (15%) were susceptible to aminopenicillins (amoxycillin/ampicillin), 23/127 (18%) to chlorampenicol, and 23/98 (23%) to co-trimoxazole. All NTS isolates were sensitive to ceftriaxone and ciprofloxacin. Conclusion In Sub-saharan Africa, sepsis with NTS should be considered in children with symptoms of pneumonia and aminopenicillins might often not be the adequate drugs for treatment.
Collapse
|
3
|
Lorenzo-Figueras M, Pusterla N, Byrne BA, Samitz EM. In vitro evaluation of three bacterial culture systems for the recovery of Escherichia coli from equine blood. Am J Vet Res 2006; 67:2025-9. [PMID: 17144804 DOI: 10.2460/ajvr.67.12.2025] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate the effectiveness of a commercial conventional blood culture system (BCS), a commercial resin-containing BCS, and a commercial lysis-centrifugation-based BCS for the recovery of Escherichia coli from equine blood samples inoculated with that organism. SAMPLE POPULATION Samples of blood obtained from a clinically normal horse that were inoculated with E coli. PROCEDURES Blood samples were aseptically collected and inoculated with an E coli specimen (50 CFUs/mL) that had been previously isolated from a foal with sepsis. Subsequently, samples were spiked with gentamicin at a concentration of 30 mug/mL, and 10 mL of each mixture was inoculated into 1 bottle or tube of each BCS. Samples were processed and incubated according to the manufacturer's guidelines and inoculated onto 5% sheep blood agar plates. Plated samples were examined macroscopically at regular intervals for as long as 72 hours. Detection of E coli and time to detection were recorded for each medium. RESULTS Detection frequency of E coli was significantly greater by use of the resin-containing BCS (14/23 bottles) than that achieved by use of the conventional BCS (7/23 bottles) or the lysis-centrifugation-based BCS (0/10 tubes). Mean detection time (6 hours after plating) did not differ between the BCS with conventional medium and the BCS with resincontaining medium. CONCLUSIONS AND CLINICAL RELEVANCE Results suggest that a BCS with resin-containing medium may provide clinical benefit in the successful recovery of E coli from the blood of foals with sepsis that have been previously administered gentamicin.
Collapse
Affiliation(s)
- Mireia Lorenzo-Figueras
- Veterinary Medical Teaching Hospital, School of Veterinary Medicine, University of California, Davis, CA 95616, USA
| | | | | | | |
Collapse
|
4
|
Hsu KK, Pelton SI, Shapiro DS. Detection of group B streptococcal bacteremia in simulated intrapartum antimicrobial prophylaxis. Diagn Microbiol Infect Dis 2003; 45:23-7. [PMID: 12573547 DOI: 10.1016/s0732-8893(02)00480-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The diagnostic value of negative blood cultures from neonates whose mothers receive intrapartum antimicrobial prophylaxis for prevention of perinatal group B streptococcal disease is uncertain. We investigated whether blood culture medium containing resin designed to adsorb antibiotic improved group B streptococcal detection following simulated intrapartum antimicrobial prophylaxis. Group B streptococcus (Streptococcus agalactiae) was preincubated with varying antibiotic concentrations before inoculation into BACTEC Peds Plus resin-containing medium, BACTEC Standard, or Trek ESP 80A. In the presence of 10 mcg/mL ampicillin, detection of both low (<500 CFU/mL) and high (>500 CFU/mL) S. agalactiae inocula ranged between 75-100% of resin-containing medium bottles; detection rates in both non-resin-containing media were lower. When S. agalactiae was detected, it was detected sooner with resin-containing medium. The addition of gentamicin to ampicillin did not affect sensitivity of resin-containing medium for S. agalactiae. In our model, resin-containing medium more consistently and more rapidly detected S. agalactiae than did either of two non-resin-containing media, in the presence of antibiotic levels likely present in fetal sera following intrapartum antimicrobial prophylaxis.
Collapse
Affiliation(s)
- Katherine K Hsu
- Maxwell Finland Laboratory for Infectious Diseases, Boston University School of Medicine and Boston Medical Center, Boston, MA, 02118, USA.
| | | | | |
Collapse
|
5
|
Archibald LK, McDonald LC, Addison RM, McKnight C, Byrne T, Dobbie H, Nwanyanwu O, Kazembe P, Reller LB, Jarvis WR. Comparison of BACTEC MYCO/F LYTIC and WAMPOLE ISOLATOR 10 (lysis-centrifugation) systems for detection of bacteremia, mycobacteremia, and fungemia in a developing country. J Clin Microbiol 2000; 38:2994-7. [PMID: 10921966 PMCID: PMC87169 DOI: 10.1128/jcm.38.8.2994-2997.2000] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
In less-developed countries, studies of bloodstream infections (BSI) have been hindered because of the difficulty and costs of culturing blood for bacteria, mycobacteria, and fungi. During two study periods (study period I [1997] and study period II [1998]), we cultured blood from patients in Malawi by using the BACTEC MYCO/F LYTIC (MFL), ISOLATOR 10 (Isolator), Septi-Chek AFB (SC-AFB), and Septi-Chek bacterial (SC-B) systems. During study period I, blood was inoculated at 5 ml into an MFL bottle, 10 ml into an Isolator tube for lysis and centrifugation, and 10 ml into an SC-B bottle. Next, 0.5-ml aliquots of Isolator concentrate were inoculated into an SC-AFB bottle and onto Middlebrook 7H11 agar slants, chocolate agar slants, and Inhibitory Mold Agar (IMA) slants. During study period II, the SC-B and chocolate agar cultures were discontinued. MFL growth was detected by fluorescence caused by shining UV light (lambda = 365 nm) onto the indicator on the bottom of the bottle. During study period I, 251 blood cultures yielded 44 bacterial isolates. For bacteremia, the MFL was similar to the Isolator concentrate on chocolate agar (34 of 44 versus 27 of 44; P, not significant [NS]), but more sensitive than the SC-B bottle (34 of 44 versus 24 of 44; P = 0.05). For both study periods combined, 486 blood cultures yielded 37 mycobacterial and 13 fungal isolates. For mycobacteremia, the sensitivities of the MFL and Isolator concentrate in the SC-AFB bottle were similar (30 of 37 versus 29 of 37; P, NS); the MFL bottle was more sensitive than the concentrate on Middlebrook agar (30 of 37 versus 15 of 37; P = 0.002). For fungemia, the MFL bottle was as sensitive as the SC-B bottle or Isolator concentrate on chocolate agar or IMA slants. We conclude that the MFL bottle, inoculated with just 5 ml of blood and examined under UV light, provides a sensitive and uncomplicated method for comprehensive detection of BSI in less-developed countries.
Collapse
Affiliation(s)
- L K Archibald
- Hospital Infections Program, Centers for Disease Control and Prevention, Atlanta, Georgia 30333, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Rohner P, Auckenthaler R. Review on evaluations of currently available blood-culture systems. Clin Microbiol Infect 1999; 5:513-529. [PMID: 11851703 DOI: 10.1111/j.1469-0691.1999.tb00429.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Peter Rohner
- Division des Maladies Infectieuses, Laboratoire Central de Bactériologie, Hôpital Cantonal Universitaire de Genève, Geneva, Switzerland
| | | |
Collapse
|
7
|
Toikka P, Nikkari S, Ruuskanen O, Leinonen M, Mertsola J. Pneumolysin PCR-based diagnosis of invasive pneumococcal infection in children. J Clin Microbiol 1999; 37:633-7. [PMID: 9986825 PMCID: PMC84500 DOI: 10.1128/jcm.37.3.633-637.1999] [Citation(s) in RCA: 60] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/1998] [Accepted: 11/18/1998] [Indexed: 11/20/2022] Open
Abstract
Blood-based pneumolysin PCR was compared to blood culture and detection of pneumolysin immune complexes, as well as to detection of antibodies to pneumolysin and to C polysaccharide, in the diagnosis of pneumococcal infection in 75 febrile children. Invasive pneumococcal infection was suspected on clinical grounds in 67 of the febrile children, and viral infection was suspected on clinical grounds in 8 of the febrile children. In addition, 15 healthy persons were examined to test the specificity of the PCR assay. Plasma, serum, and leukocyte fractions were analyzed by PCR. The combination of all test results led to the diagnosis of pneumococcal infection in 25 patients. Pneumolysin PCR was positive in 44% of these children, an increase occurred in the pneumolysin antibodies in 39% and in the C polysaccharide antibodies in 30% of the patients; pneumolysin immune complexes were found in convalescent serum in 30%, pneumolysin immune complexes occurred in acute-phase serum samples in 16%, and a positive blood culture was found in 20% of the patients. None of the healthy controls had positive results by PCR. The results suggest that the diagnosis of Streptococcus pneumoniae infection from blood samples necessitates the use of several different assays. Pneumolysin PCR was the most sensitive assay, but its clinical value is reduced by the fact that three blood fractions are needed.
Collapse
Affiliation(s)
- P Toikka
- Department of Pediatrics, Turku University Hospital, Turku, Finland. pia@
| | | | | | | | | |
Collapse
|
8
|
Zaidi AK, Mirrett S, McDonald JC, Rubin EE, McDonald LC, Weinstein MP, Gupta M, Reller LB. Controlled comparison of bioMérieux VITAL and BACTEC NR-660 systems for detection of bacteremia and fungemia in pediatric patients. J Clin Microbiol 1997; 35:2007-12. [PMID: 9230371 PMCID: PMC229892 DOI: 10.1128/jcm.35.8.2007-2012.1997] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
The bioMérieux VITAL automated blood culture system measures a decrease in fluorescence to detect the presence of microorganisms in blood. To assess the performance of VITAL with AER aerobic medium versus that of the nonradiometric BACTEC NR-660 PEDS PLUS medium for the detection of sepsis in children, a total of 12,146 blood specimens were collected at three university medical centers and inoculated into AER and PEDS PLUS bottles that were weighed before and after filling. The sample volumes were considered adequate in 6,276 bottle pairs. The total yield of isolates was 629, of which 489 (78%) were judged to be the cause of true infections. Staphylococci (P < 0.001) and yeasts (P < 0.05) were detected more often in PEDS PLUS bottles, as were all microorganisms combined (P < 0.001). The improved detection in the PEDS PLUS medium was most marked for patients on antimicrobial therapy (P < 0.001), but remained statistically significant even for patients not on therapy (P < 0.025). There were 431 episodes of sepsis, including 407 considered adequate for analysis. Of the 363 unimicrobial episodes, 278 were detected by both bottles, 64 were detected by PEDS PLUS bottles only, and 21 were detected by AER bottles only (P < 0.01). No false-negative cultures were detected by terminal subculture of the PEDS PLUS bottles when the companion AER bottle was positive. However, there were 14 false-negative cultures (7 yeasts, 5 staphylococci, 1 Enterococcus faecalis, and 1 Enterobacter sp.) on terminal subculture of the AER bottles when the companion PEDS PLUS bottle was positive. When both systems were positive, the VITAL system detected bacteria earlier than did the BACTEC system by a mean of 1.6 h. Also, false-positive signals were less common with the VITAL system. We conclude that the VITAL system with AER medium must be modified to improve the detection of clinically important staphylococci and yeasts if it is to perform comparably to the BACTEC NR-660 nonradiometric system with PEDS PLUS medium for a pediatric population.
Collapse
Affiliation(s)
- A K Zaidi
- Clinical Microbiology Laboratory, Duke University Medical Center, Durham, North Carolina 27710, USA
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Kellogg JA, Ferrentino FL, Goodstein MH, Liss J, Shapiro SL, Bankert DA. Frequency of low level bacteremia in infants from birth to two months of age. Pediatr Infect Dis J 1997; 16:381-5. [PMID: 9109140 DOI: 10.1097/00006454-199704000-00009] [Citation(s) in RCA: 116] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND The frequency of low level bacteremia (< or = 10 colony-forming units/ml) in infants from birth to 2 months of age and the optimal volume of blood and number of blood cultures to be collected have not been well-documented. During 1991 guidelines at this hospital for collection of blood for culture from these infants were revised. METHODS Blood from each infant with suspected bacteremia was usually inoculated into an Isolator 1.5 Microbial Tube (1.5 ml of blood) and a bottle of anaerobic broth (0.5 to 3.0 ml of blood). The use of a second Isolator tube and the total blood volume recommended for culture (2 to 6 ml) depended on the weight and total blood volume of each infant. RESULTS Forty-four bacterial pathogens were recovered from the blood of 40 (2.5%) of 1589 infants. Of 34 infants from whose blood the concentration of pathogens could be determined, 23 (68%) had low level bacteremia. Of 50 isolates of pathogens recovered from Isolator cultures, 32 (64%) were detected in counts of < or = 10 colony-forming units/ml. When 2 or 3 blood culture devices were inoculated with a total of 2 to 6 ml of blood from each infant, significantly more cases of bacteremia were detected (34 (3.0%) of 1126 infants had positive blood cultures) than when only one culture device containing < or = 1.5 ml of blood was used (2 (0.5%) of 398 infants had positive blood cultures; P = 0.008). However, when 4 or more culture devices were inoculated with a total of > 6 ml of blood from each infant (5 (7.7%) of 65 infants had positive blood cultures), the difference in recovery of pathogens compared with the culturing of from 2 to 6 ml of blood per infant was not significant (P = 0.089). CONCLUSIONS Low level bacteremia was common in our infants' patient population. The culturing of up to 6 ml of blood which represented up to 4.5% of an infant's total blood volume was required for detection of the pathogens.
Collapse
Affiliation(s)
- J A Kellogg
- Clinical Microbiology Laboratory, York Hospital, PA 17405, USA.
| | | | | | | | | | | |
Collapse
|
10
|
Petti CA, Zaidi AK, Mirrett S, Reller LB. Comparison of Isolator 1.5 and BACTEC NR660 aerobic 6A blood culture systems for detection of fungemia in children. J Clin Microbiol 1996; 34:1877-9. [PMID: 8818873 PMCID: PMC229145 DOI: 10.1128/jcm.34.8.1877-1879.1996] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
The Isolator 1.5 microbial system (ISO 1.5) (Wampole Laboratories, Cranbury, N.J.) was compared with the BACTEC NR660 aerobic NR6A bottle (NR6A) (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) for the detection of fungemia in hospitalized pediatric patients. For 4,825 paired blood cultures evaluated retrospectively from April 1992 to December 1994, at least one blood culture system was positive for 89 clinically important fungal isolates involved in 36 episodes of fungemia in 34 patients. Sixty isolates (44 Candida albicans, 12 Candida parapsilosis, and 4 Candida tropicalis isolates) were recovered from both systems, 13 were recovered from NR6A bottles only (10 C. albicans, 1 C. parapsilosis, and 2 Cryptococcus neoformans isolates), and 16 were recovered from ISO 1.5 tubes only (8 C. albicans and 5 C. parapsilosis isolates and 1 C. tropicalis, 1 Candida lusitaniae, and 1 Rhodotorula glutinis isolate) (P > 0.05). For the 60 Candida isolates from both systems, the mean time to detection was the same in each system. Thirty-seven isolates were detected by both systems on the same day, 9 isolates were detected earlier by NR6A, and 14 isolates were detected earlier by ISO 1.5 (P > 0.05). Of the 36 clinically important episodes of fungemia, 22 were detected by both systems (13 C. albicans isolates and 9 other Candida isolates), 4 were detected by NR6A only (3 C. albicans isolates and 1 C. neoformans isolate), and 10 were detected by ISO 1.5 only (3 C. albicans isolates, 6 other Candida isolates, and 1 R. glutinis isolate) (P > 0.05). Of the 22 episodes in which cultures from both systems were positive at some point during the episode, 12 were detected on the same day by both systems, 8 were detected earlier by NR6A, and 2 were detected earlier by ISO 1.5. Thus, for our pediatric population, NR6A is comparable to ISO 1.5 in both yield and time to detection of yeasts in fungemic patients.
Collapse
Affiliation(s)
- C A Petti
- Clinical Microbiology Laboratory, Duke University Medical Center, Durham, North Carolina 27710, USA
| | | | | | | |
Collapse
|
11
|
Isaacman DJ, Karasic RB, Reynolds EA, Kost SI. Effect of number of blood cultures and volume of blood on detection of bacteremia in children. J Pediatr 1996; 128:190-5. [PMID: 8636810 DOI: 10.1016/s0022-3476(96)70388-8] [Citation(s) in RCA: 116] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
OBJECTIVE To determine whether bacteremia can be detected more rapidly and completely by (1) obtaining two blood cultures instead of one and/or (2) collecting a larger volume of blood. STUDY DESIGN Prospective comparison of different strategies in 300 patients undergoing blood culture for suspected bacteremia. Each patient had two samples of blood, A (2 ml) and B (9.5 ml), obtained sequentially from separate sites. The B sample was divided into three aliquots: B1 (2 ml), B2 (6 ml), and ISO (1.5 ml, quantitative culture). RESULTS A pathogen was isolated from one or more blood cultures in 30 patients (10% of cases). When measured at 24 hours, the pathogen recovery rate for the B2 sample (72%) was higher than that for the individual small-volume samples (A = 37%, B1 = 33%; p < 0.01 for each comparison) and for the combination of the two small-volume samples (A + B1 = 47%; p = 0.04). At final (7-day) reading the pathogen recovery rate for the B2 sample (83%) was higher than that for B1 (60%; p = 0.02) and similar to the recovery rate observed with the combination of the two small-volume cultures (A + B1 = 73%; p = 0.55). CONCLUSIONS Increasing the volume of blood inoculated into blood culture bottles improves the timely detection of bacteremia in pediatric patients and spares the patients the cost and pain of an additional venipuncture.
Collapse
Affiliation(s)
- D J Isaacman
- Department of Pediatrics, University of Pittsburgh School of Medicine, Pennsylvania, USA
| | | | | | | |
Collapse
|
12
|
Kellogg JA. Selection of a clinically satisfactory blood culture system: The utility of anaerobic media. ACTA ACUST UNITED AC 1995. [DOI: 10.1016/s0196-4399(00)80021-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
13
|
|
14
|
|
15
|
|