1
|
Baker G, Hill J, O'Neill F, McChesney J, Stevenson M, Beverland D. Long-term follow-up of ceramic-on-metal total hip arthroplasty. Bone Jt Open 2024; 5:971-976. [PMID: 39496282 PMCID: PMC11534456 DOI: 10.1302/2633-1462.511.bjo-2024-0087.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2024] Open
Abstract
Aims In 2015, we published the results of our ceramic-on-metal (CoM) total hip arthroplasties (THAs) performed between October 2007 and July 2009 with a mean follow-up of 34 months (23 to 45) and a revision rate of 3.1%. The aim of this paper is to present the longer-term outcomes. Methods A total of 264 patients were reviewed at a mean of 5.8 years (4.6 to 7.2) and 10.1 years (9.2 to 10.6) to determine revision rate, pain, outcome scores, radiological analysis, and blood ion levels. Those who were unwilling or unable to travel were contacted by telephone. Results The all-cause revision rate at six years was 3.1% (eight THAs), increasing to 8.8% (18 THAs) at ten years. Of these, there were four and then seven bearing-related revisions at six and ten years, respectively. There was a statistically significant deterioration in the visual analogue scale pain score and Oxford Hip Score (OHS) between six and ten years. There were 18 CoM THAs in 17 patients who had a cobalt or chromium level over 4 ppb and ten CoM THAs in nine patients who had a cobalt or chromium level higher than 7 ppb with a statistically significant increase in chromium levels only between the two timepoints. Overall, 84 stems (39.1%) had significant radiolucent lines at ten years compared to 65 (25.5%) at six years. Conclusion When compared to the original review, there has been a significant deterioration in pain score, OHS, radiograph appearance, and, most critically, survival has fallen to 91.2%, which does not meet the Orthopaedic Data Evaluation Panel (ODEP) 10 A* 95% threshold. Although this bearing is no longer on the market, 2.5% were bearing-related revisions, which have relevance to the discussion around modular dual-mobility implants that have a similar metal interface.
Collapse
Affiliation(s)
- Gavin Baker
- Primary Joint Unit, Musgrave Park Hospital, Belfast, UK
| | - Janet Hill
- Primary Joint Unit, Musgrave Park Hospital, Belfast, UK
| | | | | | | | | |
Collapse
|
2
|
Sun Y, Cheng KY, Kanniyappan H, Ramachandran RA, Neto MQ, McNallan M, Pourzal R, Lundberg H, Mathew MT. Fretting-corrosion Apparatus with Low Magnitude Micro-motion (≤5 μm): Development and Preliminary Outcome. RESEARCH SQUARE 2023:rs.3.rs-3359897. [PMID: 37886457 PMCID: PMC10602084 DOI: 10.21203/rs.3.rs-3359897/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2023]
Abstract
Fretting-corrosion is one of the failure processes in many applications, including biomedical implants. For example, the modern design of hip implants with multiple components offers better flexibility and inventory storage. However, it will trigger the fretting at the implant interfaces with a small displacement amplitude (< 5 µm) and usually in a partial slip region. Although many studies have been reported on the fretting, they have high displacement amplitude and are in the gross slip region. It is imperative to have an apparatus to overcome such limitations, specifically for hip implant applications. Therefore, this study describes the development of a fretting-corrosion apparatus with low micro-motion (≤ 5 µm) that can simultaneously monitor the corrosion process. Initial experiments with Ti6Al4V-Ti6Al4V in 0.9% saline, Ti6Al4V-Ti6Al4V in bovine calf serum (BCS), and ZrO2-Ti6Al4V in BCS were conducted to validate the system. As a result, the fretting regime of all groups remained partially slip region throughout the 3600 cycles, and the possible failure mechanisms are proposed in this manuscript.
Collapse
Affiliation(s)
- Yani Sun
- University of Illinois at Chicago
| | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Royhman D, Pourzal R, Hall D, Lundberg HJ, Wimmer MA, Jacobs J, Hallab NJ, Mathew MT. Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater 2021; 118:104443. [PMID: 33752094 DOI: 10.1016/j.jmbbm.2021.104443] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 03/03/2020] [Accepted: 02/27/2021] [Indexed: 10/21/2022]
Abstract
Contemporary hip implants feature a modular design. Increased reported failure rates associated with the utilization of modular junctions have raised many clinical concerns. Typically, these modular interfaces contain circumferential machining marks (threads or microgrooves), but the effect of the machining marks on the fretting-corrosion behavior of total hip implant materials is unknown. This study reports the effects of microgrooves on the fretting-corrosion behavior of hip implant materials. The flat portions of two cylindrical, polished, CrCrMo alloy pins were loaded horizontally against one rectangular Ti alloy rod. Two surface preparation groups were used for the Ti6Al4V rod (polished and machined). The polished group was prepared using the same methods as the CoCrMo pins. The machined samples were prepared by creating parallel lines on the rod surfaces to represent microgrooves present on the stem tapers of head-neck modular junctions. Newborn calf serum (30 g/L protein content; 37 °C) at pH of levels of 7.6 and 3.0 were used to simulate the normal joint fluid and a lowered pH within a crevice, respectively. The samples were tested in a fretting corrosion apparatus under a 200N normal force and a 1Hz sinusoidal fretting motion with a displacement amplitude of 25 μm. All electrochemical measurements were performed with a potentiostat in a three-electrode configuration. The results show significant differences between machined samples and polished samples in both electrochemical and mechanical responses. In all cases, the magnitude of the drop in potential was greater in the machined group compared to the polished group. The machined group showed a lower total dissipated friction energy for the entire test compared to the polished group. Additionally, the potentiostatic test measurements revealed a higher evolved charge in the machined group compared to the polished group at both pH conditions (pH 7.6 and 3.0). The machined surfaces lowered the overall dissipated friction energy at pH 7.6 compared to pH 3.0, but also compromised electrochemical performance in the tested conditions. Therefore, the role of synergistic interaction of wear and corrosion with surface topographical changes is evident from the outcome of the study. Despite the shift towards higher electrochemical destabilization in the machined group, both polished and machined groups still exhibited a mechanically dominated degradation.
Collapse
Affiliation(s)
- Dmitry Royhman
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA; Department of Biomedical Science, UIC School of Medicine, Rockford, IL, USA
| | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Deborah Hall
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Hannah J Lundberg
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Markus A Wimmer
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Joshua Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Nadim J Hallab
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Mathew T Mathew
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA; Department of Biomedical Science, UIC School of Medicine, Rockford, IL, USA.
| |
Collapse
|
4
|
Nahhas CR, Yi PH, Moric M, Puri R, Jacobs JJ, Sporer SM. High Failure at a Minimum 5-Year Follow-Up in Primary Total Hip Arthroplasty Using a Modular Femoral Trunnion. J Arthroplasty 2019; 34:1395-1399. [PMID: 30982763 DOI: 10.1016/j.arth.2019.03.033] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Revised: 03/10/2019] [Accepted: 03/12/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Modular femoral trunnions enable the surgeon to independently adjust offset, leg length, and anteversion in total hip arthroplasty (THA). However, modularity may result in an increased risk of fretting and corrosion along with a higher risk of implant dissociation or fracture. The purpose of this study is to evaluate mid-term survivorship of THAs using a cementless modular system. METHODS A consecutive series of 221 patients who underwent a primary THA using the ALFA II modular stem by a single surgeon between 2002 and 2004 were reviewed. Survivorship of the ALFA II modular hip system was evaluated at a minimum of 5 years postoperatively. RESULTS Of the 221 patients, 28 (12.7%) died from causes unrelated to the surgery before adequate follow-up, and 64 (29.0%) patients were lost to follow-up. The remaining 129 patients had a mean 6.5-year (range: 5-8 years) follow-up. All-cause survivorship of the modular stem system was 81% (95% confidence interval = 69-90) at a mean 6.5-year follow-up. Of the 25 (19.4%) cases requiring revision surgery, 52.0% was for dissociation of the modular components, 32.0% was for fracture of the prosthesis, 12.0% was for instability/multiple dislocations, and 4.0% was for chronic septic THA. Body mass index (odds ratio = 1.080) and offset (odds ratio = 1.254) were independent risk factors for mechanical failures of the modular stem system. CONCLUSION The modular stem hip system of interest in this study demonstrates a high failure rate at mid-term follow-up, and we caution against the use of similar designs in primary THAs.
Collapse
Affiliation(s)
- Cindy R Nahhas
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Paul H Yi
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Mario Moric
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Rajeev Puri
- Department of Orthopedic Surgery, Riverside Hospital, Kankakee, IL
| | - Joshua J Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Scott M Sporer
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| |
Collapse
|
5
|
Mueller U, Braun S, Schroeder S, Sonntag R, Kretzer JP. Same Same but Different? 12/14 Stem and Head Tapers in Total Hip Arthroplasty. J Arthroplasty 2017; 32:3191-3199. [PMID: 28552447 DOI: 10.1016/j.arth.2017.04.027] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2017] [Revised: 03/27/2017] [Accepted: 04/18/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Taper corrosion has been identified to be a major concern in total hip arthroplasty during the past years. So far, the mechanisms that lead to taper corrosion in modular taper junctions are not fully understood. However, it has been shown that corrosion is also influenced by the geometry and topography of the taper, and these parameters vary among the implant manufacturers. The purpose of this study was to investigate the variations of common stem and head tapers regarding design and surface characteristics. METHODS An analysis of selected commercially available 12/14 stem and head tapers was performed. As geometric parameters, the taper angle, the opening taper diameter, and the taper length were measured using a coordinate measuring machine. Several topographic parameters were determined using a tactile roughness measurement instrument. RESULTS Although all investigated tapers are so-called 12/14 tapers, this study showed that the stem and head tapers differ among the manufacturers. The stem tapers were clearly different in both geometry and topography, and the range in variation of the topographic parameter was greater than it was for the geometric parameter. In contrast, the head tapers were different in their geometry, although not in topography. CONCLUSION Ultimately, this study provides an overview on the characteristics and variations of modular hip taper connections, and in addition, a new classification system regarding the surface finish is presented. These findings could be further considered in experimental corrosion or retrieval studies.
Collapse
Affiliation(s)
- Ulrike Mueller
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Steffen Braun
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Stefan Schroeder
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Robert Sonntag
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - J Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| |
Collapse
|
6
|
Krull A, Morlock MM, Bishop NE. The Influence of Contamination and Cleaning on the Strength of Modular Head Taper Fixation in Total Hip Arthroplasty. J Arthroplasty 2017. [PMID: 28625686 DOI: 10.1016/j.arth.2017.05.009] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Intraoperative interface contamination of modular head-stem taper junctions of hip implants can lead to poor fixation strength, causing fretting and crevice corrosion or even stem taper fracture. Careful cleaning before assembly should help to reduce these problems. The purpose of this study was to determine the effect of cleaning (with and without drying) contaminated taper interfaces on the taper fixation strength. METHODS Metal or ceramic heads were impacted onto titanium alloy stem tapers with cleaned or contaminated (fat or saline solution) interfaces. The same procedure was performed after cleaning and drying the contaminated interfaces. Pull-off force was used to determine the influence of contamination and cleaning on the taper strength. RESULTS Pull-off forces after contamination with fat were significantly lower than those for uncontaminated interfaces for both head materials. Pull-off forces after application of saline solution were not significantly different from those for uncontaminated tapers. However, a large variation in taper strength was observed, pull-off forces for cleaned and dried tapers were similar to those for uncontaminated tapers for both head materials. CONCLUSION Intraoperative contamination of taper interfaces may be difficult to detect but has a major influence on taper fixation strength. Cleaning of the stem taper with saline solution and drying with gauze directly before assembly allows the taper strength of the pristine components to be achieved. Not drying the taper results in a large variation in pull-off forces, emphasizing that drying is essential for sufficient and reproducible fixation strength.
Collapse
Affiliation(s)
- Annika Krull
- Institute of Biomechanics, Hamburg University of Technology, Hamburg, Germany
| | - Michael M Morlock
- Institute of Biomechanics, Hamburg University of Technology, Hamburg, Germany
| | - Nicholas E Bishop
- Institute of Biomechanics, Hamburg University of Technology, Hamburg, Germany; Department of Medical Technology, Faculty of Life Science, HAW Hamburg University of Applied Sciences, Hamburg, Germany
| |
Collapse
|
7
|
Shah KM, Orton P, Mani N, Wilkinson JM, Gartland A. Osteocyte physiology and response to fluid shear stress are impaired following exposure to cobalt and chromium: Implications for bone health following joint replacement. J Orthop Res 2017; 35:1716-1723. [PMID: 27673573 PMCID: PMC5603770 DOI: 10.1002/jor.23449] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2016] [Accepted: 09/23/2016] [Indexed: 02/04/2023]
Abstract
The effects of metal ion exposure on osteocytes, the most abundant cell type in bone and responsible for coordinating bone remodeling, remain unclear. However, several studies have previously shown that exposure to cobalt (Co2+ ) and chromium (Cr3+ ), at concentrations equivalent to those found clinically, affect osteoblast and osteoclast survival and function. In this study, we tested the hypothesis that metal ions would similarly impair the normal physiology of osteocytes. The survival, dendritic morphology, and response to fluid shear stress of the mature osteocyte-like cell-line MLO-Y4 following exposure to clinically relevant concentrations and combinations of Co and Cr ions were measured in 2D-culture. Exposure of MLO-Y4 cells to metal ions reduced cell number, increased dendrites per cell and increased dendrite length. We found that combinations of metal ions had a greater effect than the individual ions alone, and that Co2+ had a predominate effect on changes to cell numbers and dendrites. Combined metal ion exposure blunted the responses of the MLO-Y4 cells to fluid shear stress, including reducing the intracellular calcium responses and modulation of genes for the osteocyte markers Cx43 and Gp38, and the signaling molecules RANKL and Dkk-1. Finally, we demonstrated that in the late osteoblasts/early osteocytes cell line MLO-A5 that Co2+ exposure had no effect on mineralization, but Cr3+ treatment inhibited mineralization in a dose-dependent manner, without affecting cell viability. Taken together, these data indicate that metal exposure can directly affect osteocyte physiology, with potential implications for bone health including osseointegration of cementless components, and periprosthetic bone remodeling. © 2016 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 35:1716-1723, 2017.
Collapse
Affiliation(s)
- Karan M. Shah
- Department of Oncology and MetabolismThe University of SheffieldBeech Hill RdSheffield S10 2RXUnited Kingdom
| | - Peter Orton
- Department of Oncology and MetabolismThe University of SheffieldBeech Hill RdSheffield S10 2RXUnited Kingdom
| | - Nick Mani
- Department of Oncology and MetabolismThe University of SheffieldBeech Hill RdSheffield S10 2RXUnited Kingdom
| | - Jeremy Mark Wilkinson
- Department of Oncology and MetabolismThe University of SheffieldBeech Hill RdSheffield S10 2RXUnited Kingdom
| | - Alison Gartland
- Department of Oncology and MetabolismThe University of SheffieldBeech Hill RdSheffield S10 2RXUnited Kingdom
| |
Collapse
|
8
|
Bitter T, Khan I, Marriott T, Lovelady E, Verdonschot N, Janssen D. A combined experimental and finite element approach to analyse the fretting mechanism of the head-stem taper junction in total hip replacement. Proc Inst Mech Eng H 2017; 231:862-870. [PMID: 28599593 PMCID: PMC5562336 DOI: 10.1177/0954411917713774] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Fretting corrosion at the taper interface of modular hip implants has been implicated as a possible cause of implant failure. This study was set up to gain more insight in the taper mechanics that lead to fretting corrosion. The objectives of this study therefore were (1) to select experimental loading conditions to reproduce clinically relevant fretting corrosion features observed in retrieved components, (2) to develop a finite element model consistent with the fretting experiments and (3) to apply more complicated loading conditions of activities of daily living to the finite element model to study the taper mechanics. The experiments showed similar wear patterns on the taper surface as observed in retrievals. The finite element wear score based on Archard’s law did not correlate well with the amount of material loss measured in the experiments. However, similar patterns were observed between the simulated micromotions and the experimental wear measurements. Although the finite element model could not be validated, the loading conditions based on activities of daily living demonstrate the importance of assembly load on the wear potential. These findings suggest that finite element models that do not incorporate geometry updates to account for wear loss may not be appropriate to predict wear volumes of taper connections.
Collapse
Affiliation(s)
- Thom Bitter
- 1 Orthopaedic Research Lab, Radboudumc, Nijmegen, The Netherlands
| | | | | | | | - Nico Verdonschot
- 1 Orthopaedic Research Lab, Radboudumc, Nijmegen, The Netherlands.,3 University of Twente, Enschede, The Netherlands
| | - Dennis Janssen
- 1 Orthopaedic Research Lab, Radboudumc, Nijmegen, The Netherlands
| |
Collapse
|
9
|
Jauch-Matt SY, Miles AW, Gill HS. Effect of trunnion roughness and length on the modular taper junction strength under typical intraoperative assembly forces. Med Eng Phys 2016; 39:94-101. [PMID: 27913177 DOI: 10.1016/j.medengphy.2016.11.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2016] [Revised: 10/15/2016] [Accepted: 11/13/2016] [Indexed: 01/24/2023]
Abstract
Modular hip implants are at risk of fretting-induced postoperative complications most likely initiated by micromotion between adjacent implant components. A stable fixation between ball head and stem-neck taper is critical to avoid excessive interface motions. Therefore, the aim of this study was to identify the effect of trunnion roughness and length on the modular taper strength under typical intraoperative assembly forces. Custom-made Titanium trunnions (standard/mini taper, smooth/grooved surface finish) were assembled with modular Cobalt-chromium heads by impaction with peak forces ranging from 2kN to 6kN. After each assembly process these were disassembled with a materials testing machine to detect the pull-off force as a measure for the taper strength. As expected, the pull-off forces increased with rising peak assembly force (p < 0.001). For low and moderate assembly forces, smooth standard tapers offered higher pull-off forces compared to grooved tapers (p < 0.038). In the case of an assembly force of 2kN, mini tapers showed a higher taper strength than standard ones (p=0.037). The results of this study showed that smooth tapers provided a higher strength for taper junctions. This higher taper strength may reduce the risk of fretting-related complications especially in the most common range of intraoperative assembly forces.
Collapse
Affiliation(s)
- S Y Jauch-Matt
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom.
| | - A W Miles
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom.
| | - H S Gill
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, United Kingdom.
| |
Collapse
|
10
|
MacLeod AR, Sullivan NPT, Whitehouse MR, Gill HS. Large-diameter total hip arthroplasty modular heads require greater assembly forces for initial stability. Bone Joint Res 2016; 5:338-46. [PMID: 27496914 PMCID: PMC5013896 DOI: 10.1302/2046-3758.58.bjr-2016-0044.r1] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2016] [Accepted: 05/06/2016] [Indexed: 11/22/2022] Open
Abstract
Objectives Modular junctions are ubiquitous in contemporary hip arthroplasty. The head-trunnion junction is implicated in the failure of large diameter metal-on-metal (MoM) hips which are the currently the topic of one the largest legal actions in the history of orthopaedics (estimated costs are stated to exceed $4 billion). Several factors are known to influence the strength of these press-fit modular connections. However, the influence of different head sizes has not previously been investigated. The aim of the study was to establish whether the choice of head size influences the initial strength of the trunnion-head connection. Materials and Methods Ti-6Al-4V trunnions (n = 60) and two different sizes of cobalt-chromium (Co-Cr) heads (28 mm and 36 mm; 30 of each size) were used in the study. Three different levels of assembly force were considered: 4 kN; 5 kN; and 6 kN (n = 10 each). The strength of the press-fit connection was subsequently evaluated by measuring the pull-off force required to break the connection. The statistical differences in pull-off force were examined using a Kruskal–Wallis test and two-sample Mann–Whitney U test. Finite element and analytical models were developed to understand the reasons for the experimentally observed differences. Results 36 mm diameter heads had significantly lower pull-off forces than 28 mm heads when impacted at 4 kN and 5 kN (p < 0.001; p < 0.001), but not at 6 kN (p = 0.21). Mean pull-off forces at 4 kN and 5 kN impaction forces were approximately 20% larger for 28 mm heads compared with 36 mm heads. Finite element and analytical models demonstrate that the differences in pull-off strength can be explained by differences in structural rigidity and the resulting interface pressures. Conclusion This is the first study to show that 36 mm Co-Cr heads have up to 20% lower pull-off connection strength compared with 28 mm heads for equivalent assembly forces. This effect is likely to play a role in the high failure rates of large diameter MoM hips. Cite this article: A. R. MacLeod, N. P. T. Sullivan, M. R. Whitehouse, H. S. Gill. Large-diameter total hip arthroplasty modular heads require greater assembly forces for initial stability. Bone Joint Res 2016;5:338–346. DOI: 10.1302/2046-3758.58.BJR-2016-0044.R1.
Collapse
Affiliation(s)
- A R MacLeod
- University of Bath, Claverton Down Rd, Bath, North East Somerset BA2 7AY, UK
| | - N P T Sullivan
- Southmead Hospital, Department of Trauma and Orthopaedics, North Bristol NHS Trust, Southmead Way, Bristol, BS10 5NB, UK
| | - M R Whitehouse
- University of Bristol, Musculoskeletal Research Unit, Southmead Hospital, Bristol, UK, BS10 5NB, UK
| | - H S Gill
- University of Bath, Claverton Down Rd, Bath, North East Somerset BA2 7AY, UK
| |
Collapse
|
11
|
Abstract
Corrosion of metallic implants in contact with body fluids is unavoidable, especially at interfaces where movement occurs or in gaps. Corrosion became clinically relevant with the introduction of large modular metal-on-metal total hip joint articulations (MoM THA) early in the 21st century. This review attempts to summarise the scientific knowledge about taper problems available at the time of introduction of these bearings, why this "disaster" could happen. It is speculated that changes to the taper connection made in the 1990s to increase the range of motion with small heads (28 and 32 mm) reduced the mechanical strength of this connection, which did not matter for small heads. With the use of large and very large metal heads in MoM articulations, which have a larger lever arm and can generate high friction in unfavourable situations, suddenly the taper interface exhibited corrosion problems on a previously unknown scale. It is speculated that due to the higher mechanical loading with larger heads, the taper connection became less forgiving with respect to assembly conditions, contamination, manufacturing tolerances and other factors, which are yet not known. Since no major clinical problems had been reported before the introduction of these bearings and the pre-clinical testing was very successful, the disaster took its course. The patient-implant-surgeon system is a very complex intrinsically hazardous system. Pre-clinical testing addresses few and defined factors and such, good results cannot be directly transferred to the clinical reality. A controlled stepwise introduction of innovations is required.
Collapse
|
12
|
Basic principles and uniform terminology for the head-neck junction in hip replacement. Hip Int 2016; 25:115-9. [PMID: 25362881 DOI: 10.5301/hipint.5000204] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 10/03/2014] [Indexed: 02/04/2023]
Abstract
Recent problems with large head metal on metal hip replacements have spiked renewed interest in the head-neck junction. A thorough knowledge of the principles of the locking mechanism, the assembly technique and affecting factors on the strength of this junction is needed. Currently a confusing variability in terms is used to describe this junction. This overcomplicates an already complex issue. The purpose of this literature review is to collect and list the different terms used and to propose a uniform terminology. Two authors independently searched the electronic databases of PubMed, CINAHL and MEDLINE with specific key words and combinations according to the PRISMA guidelines. The initial search yielded a total of 518 articles with ultimately 53 articles included in the present analysis. No consensus for a uniform term for the 2 sides of the head-stem junction was found. Since there is already pronounced variability in taper designs between different manufacturers (even so similarly named, e.g. "12/14"), a uniform terminology could be the first step to simplify the situation. "Male" and "female taper" is proposed as the appropriate terminology for the stem and head junction in hip replacement, respectively. The importance of the assembly technique understanding the principles of the locking mechanism is emphasised.
Collapse
|
13
|
Royhman D, Patel M, Runa MJ, Jacobs JJ, Hallab NJ, Wimmer MA, Mathew MT. Fretting-corrosion in Hip Implant Modular Junctions: New Experimental Set-up and Initial Outcome. TRIBOLOGY INTERNATIONAL 2015; 91:235-245. [PMID: 26405372 PMCID: PMC4576847 DOI: 10.1016/j.triboint.2015.04.032] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Modern hip prostheses feature a modular implant design with at least one tapered junction. This design can lead to several complications due to the introduction of additional interfaces, which are subjected to various loading conditions and micromotion. The main objective of current study is to develop a fretting corrosion apparatus, which is able characterize the mechanical and electrochemical behaviour of various existing metal alloy couples during fretting motion. This study describes the design and the main considerations during the development of a novel fretting corrosion apparatus, as well as determination of the machine compliance and the initial testing results. Machine compliance considerations and frictional interactions of the couples are discussed in detail. For the preliminary tests, metal alloy pins, made of Ti6Al4V and wrought high-carbon CoCrMo were mechanically polished to a surface roughness of less than 20nm. 2 pins (Diameter = 11mm) of either Ti6Al4V or CoCrMo were loaded onto a Ti6Al4V alloy rod at a normal force of 200N. The interface types included: Ti6Al4V-Ti6Al4V-Ti6Al4V, Ti6Al4V-Ti6Al4V-CoCrMo, and CoCrMo-Ti6Al4V-CoCrMo. The Ti6Al4V rod articulated against the metal alloy pins in a sinusoidal fretting motion with a displacement amplitude of ±50μm. Bovine calf serum (30g/L of protein content) was selected as a lubricant and tested at 2 different pH levels (pH 3.0 and 7.6). In all cases, current and friction energy were monitored during the fretting process. The results indicated distinct, material-specific current evolutions and friction energies. No significant differences were observed in electrochemical or mechanical behaviour in response to pH change. In general, Ti6Al4V-Ti6Al4V-Ti6Al4V couples displayed the earliest passivation and superior electrochemical behaviour compared to Ti6Al4V-Ti6Al4V-CoCrMo and CoCrMo-Ti6Al4V-CoCrMo under fretting conditions. In addition, fluctuations in current were observed in specific regions at all instances where Ti6Al4V was coupled with Ti6Al4V. These fluctuations were not observed in instances where Ti6Al4V was coupled with CoCrMo. These findings suggest transitions in the degradation mechanisms at the modular junction as a function of material couples/contacts. The findings may assist in improving the current hip modular junctions.
Collapse
Affiliation(s)
- D Royhman
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - M Patel
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA ; Department of Biotechnology, University of Illinois at Chicago Medical College, Rockford, IL, USA
| | - M J Runa
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA ; CMEMS - Center MicroElectroMechanical Systems, University of Minho, Azurém, Guimarães, Portugal
| | - J J Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - N J Hallab
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - M A Wimmer
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - M T Mathew
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
14
|
Witt F, Bosker BH, Bishop NE, Ettema HB, Verheyen CCPM, Morlock MM. The relation between titanium taper corrosion and cobalt-chromium bearing wear in large-head metal-on-metal total hip prostheses: a retrieval study. J Bone Joint Surg Am 2014; 96:e157. [PMID: 25232087 DOI: 10.2106/jbjs.m.01199] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Revision of hip implants due to adverse tissue reactions to metal debris has been associated with wear and corrosion of the metal-on-metal bearing articulation and the modular taper interface. Bearing articulation wear is increased in conditions of poor lubrication, which can also lead to high friction moments that may cause corrosion at the taper interface. This suggests that wear of the bearing and increased corrosion of the taper interface should occur simultaneously, which was investigated in this study. METHODS Forty-three large-diameter cobalt-chromium bearings of the same design, implanted with a titanium stem using a titanium adapter, were retrieved at revision at a single center. Retrievals were grouped according to visual inspection of the female taper surface of the adapter into slight and severe corrosion groups. Volume change of bearing and taper surfaces was assessed using a coordinate measurement machine. Serum ion concentrations were determined for forty-three patients, whereas tissue metal concentration was measured for twelve patients. RESULTS Severe taper corrosion was observed in 30% of the retrievals. Corrosion was observed either as material deposition or wear. The overall bearing wear rate was significantly higher in the group with severe taper corrosion than in the group with slight corrosion (7.2 ± 9.0 mm(3)/yr versus 3.1 ± 6.8 mm(3)/yr, respectively; p = 0.023) as were the serum cobalt (40.5 ± 44.9 μg/L versus 15.2 ± 23.9 μg/L, respectively; p = 0.024) and chromium ion concentrations (32.7 ± 32.7 μg/L versus 12.0 ± 15.1 μg/L, respectively; p = 0.019). Serum metal ion concentrations were more consistent indicators of wear than tissue metal concentrations. CONCLUSIONS The increased bearing articulation wear and serum metal ion concentrations in cases with taper interface corrosion support the hypothesis that increased friction in the joint articulation is one of the factors responsible for simultaneous articulation and taper damage. However, independent taper or bearing damage was also observed, suggesting that other factors are involved in the process.
Collapse
Affiliation(s)
- F Witt
- Biomechanics Section, TUHH Hamburg University of Technology, Denickestraße 15, 21073 Hamburg, Germany. E-mail address for F. Witt: . E-mail address for N.E. Bishop: . E-mail address for M.M. Morlock:
| | - B H Bosker
- Department of Orthopedic Surgery, Isala Clinics, P.O. Box 10400, 8000 GK, Zwolle, The Netherlands. E-mail address for B.H. Bosker: . E-mail address for H.B. Ettema: . E-mail address for C.C.P.M. Verheyen:
| | - N E Bishop
- Biomechanics Section, TUHH Hamburg University of Technology, Denickestraße 15, 21073 Hamburg, Germany. E-mail address for F. Witt: . E-mail address for N.E. Bishop: . E-mail address for M.M. Morlock:
| | - H B Ettema
- Department of Orthopedic Surgery, Isala Clinics, P.O. Box 10400, 8000 GK, Zwolle, The Netherlands. E-mail address for B.H. Bosker: . E-mail address for H.B. Ettema: . E-mail address for C.C.P.M. Verheyen:
| | - C C P M Verheyen
- Department of Orthopedic Surgery, Isala Clinics, P.O. Box 10400, 8000 GK, Zwolle, The Netherlands. E-mail address for B.H. Bosker: . E-mail address for H.B. Ettema: . E-mail address for C.C.P.M. Verheyen:
| | - M M Morlock
- Biomechanics Section, TUHH Hamburg University of Technology, Denickestraße 15, 21073 Hamburg, Germany. E-mail address for F. Witt: . E-mail address for N.E. Bishop: . E-mail address for M.M. Morlock:
| |
Collapse
|
15
|
Jauch S, Coles L, Ng L, Miles A, Gill H. Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems. Med Eng Phys 2014; 36:1140-6. [DOI: 10.1016/j.medengphy.2014.06.011] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2013] [Revised: 05/25/2014] [Accepted: 06/17/2014] [Indexed: 11/30/2022]
|
16
|
Tribocorrosion and oral and maxillofacial surgical devices. Br J Oral Maxillofac Surg 2014; 52:396-400. [DOI: 10.1016/j.bjoms.2014.02.010] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2014] [Accepted: 02/11/2014] [Indexed: 02/08/2023]
|
17
|
Design parameters and the material coupling are decisive for the micromotion magnitude at the stem–neck interface of bi-modular hip implants. Med Eng Phys 2014; 36:300-7. [DOI: 10.1016/j.medengphy.2013.11.009] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2013] [Revised: 11/04/2013] [Accepted: 11/17/2013] [Indexed: 11/20/2022]
|
18
|
Elkins JM, Callaghan JJ, Brown TD. Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis. Clin Orthop Relat Res 2014; 472:529-42. [PMID: 24218160 PMCID: PMC3890205 DOI: 10.1007/s11999-013-3244-8] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Large-diameter femoral heads for metal-on-metal THA hold theoretical advantages of joint stability and low bearing surface wear. However, recent reports have indicated an unacceptably high rate of wear-associated failure with large-diameter bearings, possibly due in part to increased wear at the trunnion interface. Thus, the deleterious consequences of using large heads may outweigh their theoretical advantages. QUESTIONS/PURPOSES We investigated (1) to what extent femoral head size influenced stability in THA for several dislocation-prone motions; and the biomechanics of wear at the trunnion interface by considering the relationship between (2) wear potential and head size and (3) wear potential and other factors, including cup orientation, type of hip motion, and assembly/impaction load. METHODS Computational simulations were executed using a previously validated nonlinear contact finite element model. Stability was determined at 36 cup orientations for five distinct dislocation challenges. Wear at the trunnion interface was calculated for three separate cup orientations subjected to gait, stooping, and sit-to-stand motions. Seven head diameters were investigated: 32 to 56 mm, in 4-mm increments. RESULTS Stability improved with increased diameter, although diminishing benefit was seen for sizes of greater than 40 mm. By contrast, contact stress and computed wear at the trunnion interface all increased unabatedly with increasing head size. Increased impaction forces resulted in only small decreases in trunnion wear generation. CONCLUSIONS These data suggest that the theoretical advantages of large-diameter femoral heads have a limit. Diameters of greater than 40 mm demonstrated only modest improvement in terms of joint stability yet incurred substantial increase in wear potential at the trunnion. CLINICAL RELEVANCE Our model has potential to help investigators and designers of hip implants to better understand the optimization of trunnion design for long-term durability.
Collapse
Affiliation(s)
- Jacob M. Elkins
- />Department of Orthopaedics and Rehabilitation, University of Iowa, Iowa City, IA USA , />Department of Biomedical Engineering, University of Iowa, Iowa City, IA USA
| | - John J. Callaghan
- />Department of Orthopaedics and Rehabilitation, University of Iowa, Iowa City, IA USA , />Department of Biomedical Engineering, University of Iowa, Iowa City, IA USA , />Iowa City Veterans Administration Medical Center, Iowa City, IA USA
| | - Thomas D. Brown
- />Department of Orthopaedics and Rehabilitation, University of Iowa, Iowa City, IA USA , />Department of Biomedical Engineering, University of Iowa, Iowa City, IA USA , />Orthopaedic Biomechanics Laboratory, University of Iowa, 2181 Westlawn, Iowa City, IA 52242 USA
| |
Collapse
|
19
|
Abstract
A modular femoral head–neck junction has practical advantages in total hip replacement. Taper fretting and corrosion have so far been an infrequent cause of revision. The role of design and manufacturing variables continues to be debated. Over the past decade several changes in technology and clinical practice might result in an increase in clinically significant taper fretting and corrosion. Those factors include an increased usage of large diameter (36 mm) heads, reduced femoral neck and taper dimensions, greater variability in taper assembly with smaller incision surgery, and higher taper stresses due to increased patient weight and/or physical activity. Additional studies are needed to determine the role of taper assembly compared with design, manufacturing and other implant variables. Cite this article: Bone Joint J 2013;95-B, Supple A:3–6.
Collapse
Affiliation(s)
- A. J. Wassef
- Joint Replacement Institute at St. Vincent
Medical Center, 2200 West Third Street, Suite 400, Los
Angeles, California 90057, USA
| | - T. P. Schmalzried
- Joint Replacement Institute at St. Vincent
Medical Center, 2200 West Third Street, Suite 400, Los
Angeles, California 90057, USA
| |
Collapse
|
20
|
Jauch SY, Huber G, Sellenschloh K, Haschke H, Baxmann M, Grupp TM, Morlock MM. Micromotions at the taper interface between stem and neck adapter of a bimodular hip prosthesis during activities of daily living. J Orthop Res 2013; 31:1165-71. [PMID: 23553890 DOI: 10.1002/jor.22354] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2012] [Accepted: 03/05/2013] [Indexed: 02/04/2023]
Abstract
The stem-neck taper interface of bimodular hip endoprostheses bears the risk of micromotions that can result in ongoing corrosion due to removal of the passive layer and ultimately cause implant fracture. We investigated the extent of micromotions at the stem-neck interface and the seating behavior of necks of one design made from different alloys during daily activities. Modular hip prostheses (n = 36, Metha®, Aesculap AG, Germany) with neck adapters (CoCr29Mo6 or Ti6Al4V) were embedded in PMMA (ISO 7206-4) and exposed to cyclic loading with peak loads ranging from walking (Fmax = 2.3 kN) to stumbling (Fmax = 5.3 kN). Translational and rotational micromotions at the taper interface and seating characteristics during assembly and loading were determined using four eddy-current sensors. Seating during loading after implant assembly was dependent on load magnitude but not on material coupling. Micromotions in the stem-neck interface correlated positively with load levels (CoCr: 2.6-6.3 µm, Ti: 4.6-13.8 µm; p < 0.001) with Ti neck adapters exhibiting significantly larger micromotions than CoCr (p < 0.001). These findings explain why high body weights and activities related to higher loads could increase the risk of fretting-induced implant failures in clinical application, especially for Ti-Ti combinations. Still, the role of taper seating is not clearly understood.
Collapse
Affiliation(s)
- Sabrina Yvonne Jauch
- Institute of Biomechanics, TUHH Hamburg University of Technology, Denickestr. 15, 21073, Hamburg, Germany.
| | | | | | | | | | | | | |
Collapse
|
21
|
|
22
|
Jauch SY, Huber G, Hoenig E, Baxmann M, Grupp TM, Morlock MM. Influence of material coupling and assembly condition on the magnitude of micromotion at the stem-neck interface of a modular hip endoprosthesis. J Biomech 2011; 44:1747-51. [PMID: 21531416 DOI: 10.1016/j.jbiomech.2011.04.007] [Citation(s) in RCA: 79] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2010] [Revised: 02/25/2011] [Accepted: 04/04/2011] [Indexed: 11/29/2022]
Abstract
Hip prostheses with a modular neck exhibit, compared to monobloc prostheses, an additional interface which bears the risk of fretting as well as corrosion. Failures at the neck adapter of modular prostheses have been observed for a number of different designs. It has been speculated that micromotions at the stem-neck interface were responsible for these implant failures. The purpose of this study was to investigate the influence of material combinations and assembly conditions on the magnitude of micromotions at the stem-neck interface during cyclic loading. Modular (n = 24) and monobloc (n = 3) hip prostheses of a similar design (Metha, Aesculap AG, Tuttlingen, Germany) were subjected to mechanical testing according to ISO 7206-4 (F(min) = 230N, F(max) = 2300N, f = 1Hz, n = 10,000 cycles). The neck adapters (Ti-6Al-4V or Co-Cr29-Mo alloy) were assembled with a clean or contaminated interface. The micromotion between stem and neck adapter was calculated at five reference points based on the measurements of the three eddy current sensors. The largest micromotions were observed at the lateral edge of the stem-neck taper connection, which is in accordance with the crack location of clinically failed prostheses. Titanium neck adapters showed significantly larger micromotions than cobalt-chromium neck adapters (p = 0.005). Contaminated interfaces also exhibited significantly larger micromotions (p < 0.001). Since excessive micromotions at the stem-neck interface might be involved in the process of implant failure, special care should be taken to clean the interface prior to assembly and titanium neck adapters with titanium stems should generally be used with caution.
Collapse
Affiliation(s)
- S Y Jauch
- Biomechanics Section, TUHH Hamburg University of Technology, Denickestr 15, 21073 Hamburg, Germany.
| | | | | | | | | | | |
Collapse
|
23
|
Sakai T, Ohzono K, Nishii T, Miki H, Takao M, Sugano N. A modular femoral neck and head system works well in cementless total hip replacement for patients with developmental dysplasia of the hip. ACTA ACUST UNITED AC 2010; 92:770-6. [DOI: 10.1302/0301-620x.92b6.23001] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
We compared a modular neck system with a non-modular system in a cementless anatomical total hip replacement (THR). Each group consisted of 74 hips with developmental hip dysplasia. Both groups had the same cementless acetabular component and the same articulation, which consisted of a conventional polyethylene liner and a 28 mm alumina head. The mean follow-up was 14.5 years (13 to 15), at which point there were significant differences in the mean total Harris hip score (modular/non-modular: 98.6 (64 to 100)/93.8 (68 to 100)), the mean range of abduction (32° (15° to 40°)/28 (0° to 40°)), use of a 10° elevated liner (31%/100%), the incidence of osteolysis (27%/79.7%) and the incidence of equal leg lengths (≥ 6 mm, 92%/61%). There was no disassociation or fracture of the modular neck. The modular system reduces the need for an elevated liner, thereby reducing the incidence of osteolysis. It gives a better range of movement and allows the surgeon to make an accurate adjustment of leg length.
Collapse
Affiliation(s)
- T. Sakai
- Department of Orthopaedic Surgery
| | - K. Ohzono
- Department of Orthopaedic Surgery, Kansai Rosai Hospital, 3-1-69, Inabasou, 660-8511, Amagasaki, Japan
| | - T. Nishii
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, 565-0871 Suita, Japan
| | - H. Miki
- Department of Orthopaedic Surgery, Osaka National Hospital, 2-1-14, Hoenzaka, Chuo-ku, 540-0006, Osaka, Japan
| | - M. Takao
- Department of Orthopaedic Surgery
| | - N. Sugano
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, 565-0871 Suita, Japan
| |
Collapse
|
24
|
Grupp TM, Weik T, Bloemer W, Knaebel HP. Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material. BMC Musculoskelet Disord 2010; 11:3. [PMID: 20047653 PMCID: PMC2824687 DOI: 10.1186/1471-2474-11-3] [Citation(s) in RCA: 178] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2009] [Accepted: 01/04/2010] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Modular neck adapters for hip arthroplasty stems allow the surgeon to modify CCD angle, offset and femoral anteversion intraoperatively. Fretting or crevice corrosion may lead to failure of such a modular device due to high loads or surface contamination inside the modular coupling. Unfortunately we have experienced such a failure of implants and now report our clinical experience with the failures in order to advance orthopaedic material research and joint replacement surgery.The failed neck adapters were implanted between August 2004 and November 2006 a total of about 5000 devices. After this period, the titanium neck adapters were replaced by adapters out of cobalt-chromium. Until the end of 2008 in total 1.4% (n = 68) of the implanted titanium alloy neck adapters failed with an average time of 2.0 years (0.7 to 4.0 years) postoperatively. All, but one, patients were male, their average age being 57.4 years (36 to 75 years) and the average weight 102.3 kg (75 to 130 kg). The failures of neck adapters were divided into 66% with small CCD of 130 degrees and 60% with head lengths of L or larger. Assuming an average time to failure of 2.8 years, the cumulative failure rate was calculated with 2.4%. METHODS A series of adapter failures of titanium alloy modular neck adapters in combination with a titanium alloy modular short hip stem was investigated. For patients having received this particular implant combination risk factors were identified which were associated with the occurRence of implant failure. A Kaplan-Meier survival-failure-analysis was conducted. The retrieved implants were analysed using microscopic and chemical methods. Modes of failure were simulated in biomechanical tests. Comparative tests included modular neck adapters made of titanium alloy and cobalt chrome alloy material. RESULTS Retrieval examinations and biomechanical simulation revealed that primary micromotions initiated fretting within the modular tapered neck connection. A continuous abrasion and repassivation process with a subsequent cold welding at the titanium alloy modular interface. Surface layers of 10 - 30 microm titanium oxide were observed. Surface cracks caused by fretting or fretting corrosion finally lead to fatigue fracture of the titanium alloy modular neck adapters. Neck adapters made of cobalt chrome alloy show significantly reduced micromotions especially in case of contaminated cone connection. With a cobalt-chromium neck the micromotions can be reduced by a factor of 3 compared to the titanium neck. The incidence of fretting corrosion was also substantially lower with the cobalt-chromium neck configuration. CONCLUSIONS Failure of modular titanium alloy neck adapters can be initiated by surface micromotions due to surface contamination or highly loaded implant components. In the present study, the patients at risk were men with an average weight over 100 kg. Modular cobalt chrome neck adapters provide higher safety compared to titanium alloy material.
Collapse
Affiliation(s)
| | - Thomas Weik
- Aesculap AG Research & Development,Tuttlingen, Germany
| | | | | |
Collapse
|
25
|
Naidu SH, Radin A. Modular ulnar head decoupling strength: a biomechanical study. J Hand Surg Am 2009; 34:1845-50. [PMID: 19969192 DOI: 10.1016/j.jhsa.2009.07.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2009] [Revised: 07/19/2009] [Accepted: 07/22/2009] [Indexed: 02/02/2023]
Abstract
PURPOSE Knowing the assembly and disassembly forces of modular ulnar head implants will be invaluable to the surgeon faced with the challenge of either revising or extracting the implant. Our goal in this study was to evaluate the decoupling strength of the modular ulnar head implant as a function of assembly impaction force for the 3 most commonly used combinations of modular ulnar head implants. METHODS Assembly forces and axial decoupling strength for 3 combinations of modular ulnar head implants were measured on an Instron 4206 instrument. Correlations between Morse taper decoupling strength and assembly forces were investigated. RESULTS The cobalt chrome head-cobalt chrome stem Morse taper couple showed the most predictable correlation with impaction assembly force, followed by cobalt chrome head-titanium stem couple and ceramic head-titanium couple, respectively. CONCLUSIONS Peak assembly impaction blow at the time of implantation determines the ultimate decoupling strength of the modular ulnar head Morse taper for all 3 material combinations studied. Prosthesis-specific regression curves will permit the surgeon to estimate decoupling force as a function of impact force.
Collapse
Affiliation(s)
- Sanjiv H Naidu
- REMI Sciences Inc, Pinnacle Health Hand Center, Exton, PA 17050, USA.
| | | |
Collapse
|
26
|
Sporer SM, DellaValle C, Jacobs J, Wimmer M. A case of disassociation of a modular femoral neck trunion after total hip arthroplasty. J Arthroplasty 2006; 21:918-21. [PMID: 16950051 DOI: 10.1016/j.arth.2005.10.014] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2005] [Accepted: 10/26/2005] [Indexed: 02/01/2023] Open
Abstract
Modular femoral heads offer the advantages of increased intraoperative flexibility through the adjustment of leg length and offset, whereas a modular femoral neck can also allow independent adjustment of femoral anteversion. Despite the potential advantages of hip systems using increased modularity, these component designs also offer a greater number of junctions through which problems may occur. This case demonstrates the potential for dissociation of a Morse taper between a modular femoral neck and stem.
Collapse
Affiliation(s)
- Scott M Sporer
- Department of Orthopaedic Surgery, Central Dupage Hospital, Winfield, Illinois, USA
| | | | | | | |
Collapse
|
27
|
Ebramzadeh E, Billi F, Sangiorgio SN, Mattes S, Schmoelz W, Dorr L. Simulation of Fretting Wear at Orthopaedic Implant Interfaces. J Biomech Eng 2005; 127:357-63. [PMID: 16060342 DOI: 10.1115/1.1894121] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Osteolysis due to wear debris is a primary cause of failure of total joint replacements. Although debris produced by the joint articulating surfaces has been studied and simulated extensively, fretting wear debris, produced at nonarticulating surfaces, has not received adequate attention. We developed a three-station fretting wear simulator to reproduce in vivo motion and stresses at the interfaces of total joint replacements. The simulator is based on the beam bending theory and is capable of producing cyclic displacement from 3to1000microns, under varying magnitudes of contact stresses. The simulator offers three potential advantages over previous studies: The ability to control the displacement by load, the ability to produce very small displacements, and dynamic normal loads as opposed to static. A pilot study was designed to test the functionality of the simulator, and verify that calculated displacements and loads produced the predicted differences between two commonly used porous ingrowth titanium alloy surfaces fretting against cortical bone. After 1.5 million cycles, the simulator functioned as designed, producing greater wear of bone against the rougher plasma-sprayed surface compared to the fiber-mesh surface, as predicted. A novel pin-on-disk apparatus for simulating fretting wear at orthopaedic implant interfaces due to micromotion is introduced. The test parameters measured with the fretting wear simulator were as predicted by design calculations, and were sufficient to measure differences in the height and weight of cortical bone pins rubbing against two porous ingrowth surfaces, plasma-sprayed titanium and titanium fiber mesh.
Collapse
Affiliation(s)
- Edward Ebramzadeh
- Biomechanics Laboratory, J. Vernon Luck, Sr, M.D. Orthopaedic Research Center, Los Angeles Orthopaedic Hospital/UCLA, The Dorr Arthritis Institute of Centinela Hospital, Inglewood, California, USA.
| | | | | | | | | | | |
Collapse
|
28
|
Oskouian RJ, Whitehill R, Samii A, Shaffrey ME, Johnson JP, Shaffrey CI. The future of spinal arthroplasty: a biomaterial perspective. Neurosurg Focus 2004; 17:E2. [PMID: 15636558 DOI: 10.3171/foc.2004.17.3.2] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Both total hip and knee arthroplasty have demonstrated outstanding clinical results. The functional spinal unit composed of the intervertebral disc and facet joints is at least as complex. The intricacies of the coupled motions of the functional spinal unit have made development of an artificial disc a challenge. There have been several failed attempts to create a disc replacement that recapitulates normal motion while providing significant longevity and a low incidence of complications.Better understanding of the biomechanics of the intervertebral disc complex and improvements in implant material have made successful intervertebral disc replacement a likely reality, now that several artificial discs have completed Food and Drug Administration clinical trials. In this manuscript the authors detail the biomaterials used in disc arthroplasty and discuss joint wear and the host response to wear debris.
Collapse
Affiliation(s)
- Rod J Oskouian
- Department of Neurological Surgery, University of Virginia Health Sciences Center, Charlottesville, Virginia, USA
| | | | | | | | | | | |
Collapse
|
29
|
Hallab NJ, Messina C, Skipor A, Jacobs JJ. Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements. J Orthop Res 2004; 22:250-9. [PMID: 15013082 DOI: 10.1016/s0736-0266(03)00186-4] [Citation(s) in RCA: 144] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/21/2003] [Indexed: 02/04/2023]
Abstract
The use of modular interlocking components is a central design feature of total joint replacements. In this investigation we hypothesized that clinically available ceramic-metal modular connections used in total hip arthroplasty release more metal through fretting corrosion than traditional metal-metal modular connections. This was investigated using an in vitro comparison of ceramic (zirconia, ZrO2) and metal (Co-alloy) femoral-head fretting upon Co-alloy stem components. In vitro fretting corrosion testing consisted of potentiodynamic monitoring and analysis of metal release from zirconia and Co-alloy 28 mm femoral heads with similar surface roughnesses (Ra=0.46 microm) on identical Co-alloy stems at 2.2 kN for 1x10(6) cycles at 2 Hz. In contrast to our original hypothesis, we found greater metal release (approximately 11-fold increase in Co and 3-fold increase in Cr) and potentiodynamic fretting of metal-metal modular junctions when compared to ceramic-metal. Potentiodynamic testing demonstrated that lower initial voltages (-266<153 mV), greater maximum voltage changes (116>56 mV, p<0.05, t-test) and voltage variability (3>0.5 mV, p<0.05, t-test) were associated with the open circuit potentials of Co-alloy on Co-alloy junctions when compared to zirconia on Co-alloy junctions. In this study of a single total hip replacement stem and head design, zirconia heads mated with Co-alloy stems produced less fretting than Co-alloy heads mated with Co-alloy stems. Although further studies are necessary with a variety of implant designs and under different experimental conditions, the evidence presented here should, in part, alleviate concerns of increases in fretting corrosion at modular junctions of ceramic-metal coupled components.
Collapse
Affiliation(s)
- Nadim James Hallab
- Department of Orthopedic Surgery, Rush Presbyterian St. Lukes Medical Center, 1653 W Congress Parkway, Chicago, IL 60612, USA.
| | | | | | | |
Collapse
|
30
|
Abstract
STUDY DESIGN Generally, implant-induced osteolysis is a manifestation of an adverse cellular response to phagocytosable particulate wear and corrosion debris. Initially termed "cement disease," particle-induced loosening was recognized by Charnley in the early 1960s. Despite the plethora of information gained over the last 40 years on the basic science of periprosthetic bone loss, much remains unanswered. The effect of unintended debris resulting from wear and corrosion (e.g., micromotion between the interconnection mechanisms in spinal implants) remains a clinical concern. The current study highlights what is known of particle-induced osteolysis and how the presence of spinal implant particulate debris deleteriously influences osseointegration of posterolateral bone graft or disrupts an established posterolateral fusion mass. Tissue explant, animal, and cell culture studies have revealed the complexity of cellular reactivity involved in aseptic particle-induced osteolysis. OBJECTIVES The objectives of this study are twofold: 1) to highlight the dominant cellular participants in total joint arthroplasty particle induced osteolysis, which are purportedly the macrophage, osteoblast, fibroblast, and osteoclast and several of the dominant chemical mediators have been identified as well, which include prostaglandin E2, tumor necrosis factor-alpha, interleukin-1, and interleukin-6; and 2) to demonstrate the potential deleterious effects of spinal implant debris using animal models and analysis of soft tissue surrounding spinal implants in symptomatic patients. METHODS There are a growing number of proinflammatory and anti-inflammatory cytokines, prostenoids, and enzymes that have been shown to play important roles in the pathology of particle-induced osteolysis. Reports that aseptic granulomatous inflammation typical of that associated with corrosion debris appear to correlate with the complexity of the implant. Titanium particulate material was used to induce effects in 34 New Zealand White rabbits where analysis included serological quantification of systemic cytokines. Postmortem microradiographic, immunocytochemical, and histopathologic assessment of the intertransverse fusion mass quantified the extent of osteolysis, local proinflammatory cytokines, osteoclasts and inflammatory infiltrates. Clinical analysis of 12 patients more than 0.4 years after spinal implants (mean 4.03, range 0.4 to 11 years) presented with late operative site pain. RESULTS Currently the etiology of this inflammation around spinal implants resembles particle-induced osteolysis around joint arthroplasties where there typically is a self-perpetuating fibroinflammatory zone adjacent to the implant, where macrophage exhaustion, reactive oxygen intermediates, and pro-inflammatory cytokines affect a host of local cell types and induce a widening zone of soft tissue damage and inflammation. Animal model analysis indicated increased levels of local inflammatory cytokines typically associated with osteolysis-tumor necrosis factor-alpha. Osteoclast cell counts and regions of osteolytic resorption lacunas were higher in the titanium-treated versus autograft-alone groups (P < 0.05), and the extent of cellular apoptosis was markedly higher in the titanium-treated sites at both time intervals. Electron microscopy indicated definitive evidence of phagocytized titanium particles and foci of local, chronic inflammatory changes in the titanium-treated sites. CLINICAL CASES 11 of 12 clinical cases demonstrated elevated tumor necrosis factor-alpha levels and an increased osteoclastic response in the vicinity of wear debris caused by dry frictional wear particles of titanium or stainless steel. Resection of the wear debris and surrounding fibroinflammatory zone resolved clinical symptoms in all 12 cases. CONCLUSIONS More basic science and clinical research is needed to develop novel strategies for gaining knowledge, and developing effective evaluation and treatment of patients with implant debris related osteolysis. Titanium debris simulating that produced by spinal implants introduced at the level of a spinal arthrodesis elicits an inflammatory cytokine mediated particulate-induced response through increased expression of intracellular TNF-alpha, increased osteoclastic activity and cellular apoptosis. This study highlighted the association between spinal implants particulate wear debris and increased potential for osteolysis. Aseptic osteolysis is among the primary reasons for failure of orthopedic implants. Increased awareness of this destructive process is becoming more important with the growing popularity of total disc arthroplasty and highly modular spinal implants.
Collapse
Affiliation(s)
- Nadim J Hallab
- Department of Orthopaedic Surgery, Rush-Presbyterian-St. Luke's Medical Center, Chicago, Illinois, USA.
| | | | | |
Collapse
|
31
|
Abstract
STUDY Knowledge gained through the clinical history of total joint replacement materials combined with the current promise of new biomaterials provides improved guidelines for biomaterial selection in total disc arthroplasty. OBJECTIVES The following will detail: 1) current biomaterials technology; 2) how current designs of total disc arthroplasty seek to optimize implant performance through judicious biomaterial selection; and 3) what technical obstacles and clinical concerns remain. METHODS Metals and polymers remain the central material components of state-of-the-art total joint arthroplasties. Polymers provide low friction surfaces for articulating bearings and some degree of shock absorption. Metals provide appropriate material properties such as high strength, ductility, fracture toughness, hardness, corrosion resistance, formability, and biocompatibility necessary for use in load-bearing roles required total disc replacement. There are three principal metal alloys used in orthopaedics and particularly in total joint replacement: 1) titanium based alloys; 2) cobalt based alloys; and 3) stainless steel alloys. Alloy specific differences in strength, ductility, and hardness generally determine which of these three alloys is used for a particular application or implant component. RESULTS Current designs. Two examples of current lumbar (Charitè and Prodisc) and cervical (Bryan and Prestige) disc replacements are compared. The similarities and differences in the biomaterials used for each demonstrate prevailing consensus and some idea of how to best optimize implant performance through biomaterial selection. CONCLUSION The primary factors governing total disc arthroplasty biomaterials are similar to those of all total joint arthroplasties: generation of wear debris is the primary source of implant degradation, and the subsequent tissue reaction to such debris is the primary factor limiting the longevity of joint replacement prostheses. Particulate debris generated by wear, fretting, or fragmentation induces the formation of an inflammatory reaction, which at a certain point promotes a foreign-body granulation tissue response that has the ability to invade the bone-implant interface. This commonly results in progressive, local bone loss that threatens the fixation of both cemented and cementless devices alike. All metal alloy implants corrode in vivo. When severe, the degradative process may reduce structural integrity of the implant, and the release of corrosion products is potentially toxic to the host. The corrosion resistance of implant alloys is primarily due to the formation of passive oxide films to prevent significant electrochemical dissolution from taking place. The result of this knowledge is a consensus of opinion as to which materials are best suited for use in current total disc arthroplasty designs, where most total disc replacement designs incorporate cobalt-chromium-molybdenum alloy endplates articulating internally on a relatively soft polymeric core and externally coated with titanium or titanium alloy for enhanced bone fixation.
Collapse
Affiliation(s)
- Nadim Hallab
- Rush Presbyterian St. Luke's Medical Center, Chicago, Illinois, USA.
| | | | | |
Collapse
|
32
|
Schramm M, Wirtz DC, Holzwarth U, Pitto RP. The Morse taper junction in modular revision hip replacement--a biomechanical and retrieval analysis. BIOMED ENG-BIOMED TE 2000; 45:105-9. [PMID: 10829545 DOI: 10.1515/bmte.2000.45.4.105] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
All biomaterials used for total joint surgery are subjected to wear mechanisms. Morse taper junctions of modular hip revision implants are predilection sites for both fretting and crevice corrosion, dissociation and breakage of the components. The aim of this study is to quantify wear and study metallurgical changes of Morse taper junctions of in-vitro and in-vivo loaded modular revision stems. Three modular revision stems (MRP-Titan, Peter Brehm GmbH, Germany) were loaded by a servohydraulic testing machine. The loads and conditions used exceeded by far the values required by ISO-standard 7206. The tests were performed with maximum axial loads of 3,500 N to 4,000 N over 10-12 x 10(6) cycles at 2 Hz. Additionally, the female part of the taper junctions were coated with blood and bone debris. The free length of the implant was set to 200 mm. One other MRP stem was investigated after retrieval following 5.5 years of in-vivo use. All contact surfaces of the modular elements were assessed by visual inspection, optical microscopy and scanning electron microscopy (SEM). The degree of plastic deformation of the male part of the morse taper junction was determined by contouroscopy. None of the morse taper junctions broke or failed mechanically. Corrosion and wear affected all tapers, especially at the medial side. The retrieved implant showed no cracks and the amount of debris measured only one third of that for the stems tested in-vitro. The present retrieval and laboratory investigations have proven, that the morse taper junctions of the MRP-titanium stem are stable and resistant to relevant wear mechanisms. The longevity of the junctions for clinical use is given. If an optimal taper design is selected, the advantages of modular femoral components in total hip revision arthroplasty will outweigh the possible risks.
Collapse
Affiliation(s)
- M Schramm
- Labor für Biomechanik, Friedrich-Alexander-Universität Erlangen-Nürnberg.
| | | | | | | |
Collapse
|
33
|
Yerby SA, Taylor JK, Park J, Shackelford JF. Corrosion at the interface. A possible solution to cobalt-chrome heads on titanium alloy stems. J Arthroplasty 1996; 11:157-62. [PMID: 8648309 DOI: 10.1016/s0883-5403(05)80010-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
The low-wear characteristics of cobalt-chrome femoral heads matched with the excellent biocompatibility and low modulus of titanium alloy femoral stems constitute the preferred combination used by many orthopaedic surgeons performing total hip arthroplasty. The combination of these materials in a synovial fluid environment, however, has proven to result in extensive crevice corrosion and metallosis of the surrounding tissues. This study investigates an alternative to the conventional mating of dissimilar metals at the head-neck junction. Five cobalt-chrome heads premated with titanium alloy sleeves were investigated by gross examination, dissecting microscopy, and scanning electron microscopy. Examination by both gross examination and dissecting microscope revealed no signs of corrosion. Scanning electron microscope examination revealed slight crevice corrosion in the only head with a +15-mm neck length.
Collapse
Affiliation(s)
- S A Yerby
- Department of Orthopaedic Research, University of California, Davis 95817, USA
| | | | | | | |
Collapse
|
34
|
Urban RM, Jacobs JJ, Gilbert JL, Galante JO. Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings. J Bone Joint Surg Am 1994; 76:1345-59. [PMID: 8077264 DOI: 10.2106/00004623-199409000-00009] [Citation(s) in RCA: 247] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Migration of solid corrosion products from the modular head-neck junction of fifteen total hip replacements to the periprosthetic tissues was studied. The devices and tissues were recovered at the time of a revision procedure or at autopsy after a mean of sixty-four months (range, eight to ninety-seven months). The prostheses had a cobalt-chromium-alloy head coupled with a cobalt-chromium-alloy or a titanium-alloy stem. The solid corrosion product was identified by electron microprobe analysis and Fourier transform infrared microprobe spectroscopy as a chromium orthophosphate hydrate-rich material. The product was present at the junction of the modular head and neck and as particles within the periprosthetic tissues as early as eight months postoperatively. In several hips, it was also present on the polyethylene bearing surface. The particles in the tissues ranged in size from less than one to 500 micrometers. They were present within histiocytes or were surrounded by foreign-body giant cells in the pseudocapsule of the hip joint; in the membranes of the femoral bone-implant interface; and at sites of femoral endosteal erosions, with and without loosening of the femoral component.
Collapse
Affiliation(s)
- R M Urban
- Department of Orthopedic Surgery, Rush-Presbyterian-St. Luke's Medical Center, Chicago, Illinois 60612
| | | | | | | |
Collapse
|