1
|
Upadhyaya AM, Hasan MK, Abdel-Khalek S, Hassan R, Srivastava MC, Sharan P, Islam S, Saad AME, Vo N. A Comprehensive Review on the Optical Micro-Electromechanical Sensors for the Biomedical Application. Front Public Health 2021; 9:759032. [PMID: 34926383 PMCID: PMC8674308 DOI: 10.3389/fpubh.2021.759032] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Accepted: 09/15/2021] [Indexed: 11/13/2022] Open
Abstract
This study presented an overview of current developments in optical micro-electromechanical systems in biomedical applications. Optical micro-electromechanical system (MEMS) is a particular class of MEMS technology. It combines micro-optics, mechanical elements, and electronics, called the micro-opto electromechanical system (MOEMS). Optical MEMS comprises sensing and influencing optical signals on micron-level by incorporating mechanical, electrical, and optical systems. Optical MEMS devices are widely used in inertial navigation, accelerometers, gyroscope application, and many industrial and biomedical applications. Due to its miniaturised size, insensitivity to electromagnetic interference, affordability, and lightweight characteristic, it can be easily integrated into the human body with a suitable design. This study presented a comprehensive review of 140 research articles published on photonic MEMS in biomedical applications that used the qualitative method to find the recent advancement, challenges, and issues. The paper also identified the critical success factors applied to design the optimum photonic MEMS devices in biomedical applications. With the systematic literature review approach, the results showed that the key design factors could significantly impact design, application, and future scope of work. The literature of this paper suggested that due to the flexibility, accuracy, design factors efficiency of the Fibre Bragg Grating (FBG) sensors, the demand has been increasing for various photonic devices. Except for FBG sensing devices, other sensing systems such as optical ring resonator, Mach-Zehnder interferometer (MZI), and photonic crystals are used, which still show experimental stages in the application of biosensing. Due to the requirement of sophisticated fabrication facilities and integrated systems, it is a tough choice to consider the other photonic system. Miniaturisation of complete FBG device for biomedical applications is the future scope of work. Even though there is a lot of experimental work considered with an FBG sensing system, commercialisation of the final FBG device for a specific application has not been seen noticeable progress in the past.
Collapse
Affiliation(s)
- Anup M. Upadhyaya
- Department of Mechanical Engineering, Amity School of Engineering and Technology (ASET), Amity University, Noida, Lucknow, India
- Department of Mechanical Engineering, The Oxford College of Engineering, Bangalore, India
- Department of Electronics and Communication Engineering, The Oxford College of Engineering, Bangalore, India
| | - Mohammad Kamrul Hasan
- Network and Communication Technology Lab, Center for Cyber Security, Faculty of Information Science and Technology, The National University of Malaysia (UKM), Bangi, Malaysia
| | - S. Abdel-Khalek
- Department of Mathematics and Statistics, College of Science, Taif University, Taif, Saudi Arabia
| | - Rosilah Hassan
- Network and Communication Technology Lab, Center for Cyber Security, Faculty of Information Science and Technology, The National University of Malaysia (UKM), Bangi, Malaysia
| | - Maneesh C. Srivastava
- Department of Mechanical Engineering, Amity School of Engineering and Technology (ASET), Amity University, Noida, Lucknow, India
- Department of Mechanical Engineering, The Oxford College of Engineering, Bangalore, India
| | - Preeta Sharan
- Department of Electronics and Communication Engineering, The Oxford College of Engineering, Bangalore, India
| | - Shayla Islam
- Institute of Computer Science and Digital Innovation, University College Sedaya International (UCSI) University, Kuala Lumpur, Malaysia
| | - Asma Mohammed Elbashir Saad
- Department of Physics College of Science and Humanities in AL-Kharj, Prince Sattam Bin Abdulaziz University, AL-Kharj, Saudi Arabia
| | - Nguyen Vo
- Department of Information Technology, Victorian Institute of Technology, Melbourne, VIC, Australia
| |
Collapse
|
2
|
Kırali K, Brimo N, Serdaroğlu DÇ. Antibody immobilization techniques in mass sensitive immunosensor: enhanced sensitivity through limited mass load. CURR ANAL CHEM 2020. [DOI: 10.2174/1573411016999201120090551] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Biosensors are analytical devices that include a sample-delivery approach between a
biological recognition element and a transducer required to convert the physicochemical change produced from the
interaction of biological molecules-receptor interaction into signal. The immunosensor is a special type of biosensors that
includes an antibody as a biorecognition element to detect analyte as antigens. In mass-sensitive sensors, antigen-antibody
interactions can be specified by measuring the frequency change and most commonly knowns are surface acoustic wave,
bulk acoustic wave, quartz crystal microbalance and microcantilevers.
Methods:
Different methods for antibody immobilization including functionalization of the transducer surface with
specific groups have been reported for antibody immobilization. This stage affects the limit of detection and overall
performance. In this review, perspectives on immobilization strategies of mass sensitive immunosensors according to
transducer types will be presented. The choice of immobilization methods and their impact on performance in terms of
capture molecule loading, orientation and signal improvement is will also be discussed.
Results:
One of the most critical point during configuration of the biorecognition layer is to improve the sensitivity.
Therefore, we initially focused on comparisons of the antibody immobilization strategies in the biorecognition layer in
terms of mass load level and high sensitivity.
Conclusion:
The lack of significant data on the mass accumulations up to the functionalization and antibody
immobilization steps, which are the basis of immusensor production, has been identified. However, mass sensitive
immunosensors have the potential to become more common and effective analytical devices for many application areas.
Collapse
Affiliation(s)
- Kübra Kırali
- Biomedical Engineering Department, Başkent University, Ankara, Turkey
| | - Nura Brimo
- Biomedical Engineering Department, Başkent University, Ankara, Turkey
| | | |
Collapse
|
3
|
Shadpour H, Allbritton NL. In situ roughening of polymeric microstructures. ACS APPLIED MATERIALS & INTERFACES 2010; 2:1086-93. [PMID: 20423129 PMCID: PMC2861798 DOI: 10.1021/am900860s] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
A method to perform in situ roughening of arrays of microstructures weakly adherent to an underlying substrate was presented. SU8, 1002F, and polydimethylsiloxane (PDMS) microstructures were roughened by polishing with a particle slurry. The roughness and the percentage of dislodged or damaged microstructures was evaluated as a function of the roughening time for both SU8 and 1002F structures. A maximal RMS roughness of 7-18 nm for the surfaces was obtained within 15-30 s of polishing with the slurry. This represented a 4-9 fold increase in surface roughness relative to that of the native surface. Less than 0.8% of the microstructures on the array were removed or damaged after 5 min of polishing. Native and roughened arrays were assessed for their ability to support fibronectin adhesion and cell attachment and growth. The quantity of adherent fibronectin was increased on roughened arrays by two-fold over that on native arrays. Cell adhesion to the roughened surfaces was also increased compared to native surfaces. Surface roughening with the particle slurry also improved the ability to stamp molecules onto the substrate during microcontact printing. Roughening both the PDMS stamp and substrate resulted in up to a 20-fold improvement in the transfer of BSA-Alexa Fluor 647 from the stamp to the substrate. Thus roughening of micrometer-scale surfaces with a particle slurry increased the adhesion of biomolecules as well as cells to microstructures with little to no damage to largescale arrays of the structures.
Collapse
Affiliation(s)
- Hamed Shadpour
- Department of Chemistry, University of North Carolina, Chapel Hill, North Carolina 27599, USA
| | - Nancy L. Allbritton
- Department of Chemistry, University of North Carolina, Chapel Hill, North Carolina 27599, USA
- Department of Biomedical Engineering, University of North Carolina, Chapel Hill, 27599, North Carolina, USA, and North Carolina State University, Raleigh, North Carolina 27695, USA
| |
Collapse
|